 Issue dateTitleTopic
ML20217K76427 September 1999Rev 0 to DCR 990247, Containment Overpressure Duration Requirement (Addendum to Calculation QDC-1000-M-0781)
ML20217K74423 April 1999Rev 1 to QDC-0010-M-0396, Quad Cities Station Unit 2:ECCS Strainer Head Loss Estimates
ML20155A67429 September 1998Rev 1 to Calculation QDC-1000-M-0454, Short Term Rhr/Core Spray Pump NPSH Analysis - Design Basic Loca
ML20155B52229 September 1998Rev 1 to QDC-1000-M-0535, Long-Term Rhr/Core Spray Pump NPSH Analysis - Design Basis Loca
ML20199K6043 December 1996Rev 1 to 93C2806.3-C002, Cable Tray & Conduit Raceway Limited Analytical Review (LAR) for USI A-46 at Quad Cities Nuclear Station. Page 71 of 98 of Incoming Submittal Not IncludedSafe Shutdown
ML20101Q7548 April 1996Rev 3 to Calculation 9200-E0-S,demonstrating That Reduction of Torsional Loads from Auxiliary Steel Will Significantly Reduce IC Values for Beam & Connections
ML20106J7924 April 1996Calculation for Checking Functional Status of Beam B4 & Cheek Plate Connection at Right End of Beam B10 in Quad Cities,Unit 1 Southeast,Rhr Corner Room
ML20101Q05830 March 1996Flaw Evaluation for 02BS-F14 Weld in Quad Cities Unit 1 Loop B Recirculation Sys
ML20101Q04819 March 1996Flaw Evaluation for 02AS-S4 Weld in Quad Cities Unit 1 Loop a Recirculation SysStress corrosion cracking
ML20101Q02718 March 1996Flaw Evaluation for 02AS-F2 Weld in Quad Cities Unit 1 Loop a Recirulation SysStress corrosion cracking
ML20101Q03611 March 1996Flaw Evaluation for 02AD-F12 Weld in Quad Cities Unit 1 Loop a Recirculation SysLiquid penetrant
ML20086E0893 July 1995Shroud Head Contact on Upper SupportFinite Element Analysis
ML20091G34615 June 1995Rev 0 to Shroud Repair Program for Quad Cities Unit 2, Shroud Head Contact on Upper Support
ML20091G35615 June 1995Rev 0 to Shroud Repair Program for Quad Cities Unit 2, Shroud Head Contact on Upper Support
ML20101E81622 November 1993Power Recovery Probabilities for Quad Cities IpeHigh winds
ML20126G10217 December 1992Rev 0 to RSA-D-92-07, LPCI Room Temperature Response Due to Loss of Room Cooler at Dresden Station
ML20058M16418 November 1992Quad-Cities 2/I Safety-Related Continuous Load Running/ Starting Voltages
ML20058M14531 July 1992Quad-Cities 1/I Safety-Related Continuous Load Running/ Starting Voltages
ML20101Q76616 June 1992RHR Pump 1C/1D Discharge Line 1-1008B-18
ML20058M17120 May 1992Second-Level Undervoltage Relay Setpoint
ML20058M1584 May 1992Quad-Cities 1/II Safety-Related Continuous Load Running/ Starting Voltages
ML20058M15420 April 1992Evaluation of Toshiba Dgcwp Starting Voltage
ML20058M14915 April 1992Evaluation of 460-Volt Diesel Generator Cooling Pump Min Starting Voltage
ML20058M16715 April 1992Quad-Cities 2/II Safety-Related Continuous Load Running/ Starting Voltages
ML20058M1743 April 1992Evaluation of DG 2 Cooling Water Pump Cooler Fan a & B Min Starting Voltage
ML20065S86916 November 1990Draft Setpoint Calculation for RPS Turbine Control Valve Fast Closure Trip Function
ML20247M28311 January 1988Rev 1 to Quad Cities,Control Room Dose Analysis,Plot of Dose as Function of Standby Gas Treatment Sys Effluent
ML20247M31924 September 1987Control Room Dose Analysis, (Suppl to Dose Calculation 546Y-M-07)
ML20247M2891 April 1987Infiltration Analysis