RS-22-054, Withdrawal of Relief Request RV-10 Associated with the Sixth Inservice Testing Interval
| ML22103A106 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 04/13/2022 |
| From: | Simpson P Constellation Energy Generation |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| RS-22-054 | |
| Download: ML22103A106 (2) | |
Text
4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office April 13, 2022 10 CFR 50.55a RS-22-054 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265
Subject:
Withdrawal of Relief Request RV-10 Associated with the Sixth lnservice Testing Interval
References:
- 1. Letter from P.R. Simpson (Constellation Energy Generation, LLC) to U.S.
Nuclear Regulatory Commission, " Submittal of Relief Requests Associated with the Sixth lnservice Testing Interval," dated February 17, 2022 (ML22048B569)
- 2. Email from R. Kuntz (U.S. Nuclear Regulatory Commission) to R.
Steinman (Constellation Energy Generation, LLC),
Subject:
Quad Cities Nuclear Power Station, Units 1 and 2 - Acceptance of Alternative RV-10 related to Code Case OMN-26, MOV Testing (EPID: L-2022-LLR-0019),
dated March 9, 2022 (ML22068A151)
On February 17, 2022, Constellation Energy Generation, LLC (CEG) submitted a request for approval of seven proposed relief requests associated with the Sixth 10-Year Inservice Testing (IST) Program Interval for Quad Cities Nuclear Power Station (QCNPS). Relief Request RV-10, "Adopt ASME OM Code Case OMN-26, 'Alternative Risk-Informed and Margin Based Rules for Inservice Testing of Motor Operated Valves'," was included in Reference 1. The March 3, 2022, publication of the Federal Register contained the final rule updating the list of approved OM Code Cases. Effective April 4, 2022, Code Case OMN-26, referenced as the basis for relief request RV-10, is an approved OM Code Case. As a result, CEG has decided to withdraw the proposed relief request and is no longer seeking NRC review and approval of RV-10, which had been accepted for review on March 9, 2022 (Reference 2).
This withdrawal applies only to relief request RV-10. CEG requests that the NRC continue to review of the remaining six relief requests included in Reference 1.
April 13, 2022 U.S. Nuclear Regulatory Commission Page 2 There are no regulatory commitments contained within this letter. Should you have any questions concerning this letter, please contact Ms. Rebecca L. Steinman at 630-657-2831.
Respectfully, Patrick R. Simpson Sr. Manager Licensing Constellation Energy Generation, LLC cc:
Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station