RBG-47367, Submittal of Cycle 17 Owners Activity Report Form (OAR-1)

From kanterella
Jump to navigation Jump to search
Submittal of Cycle 17 Owners Activity Report Form (OAR-1)
ML13175A253
Person / Time
Site: River Bend Entergy icon.png
Issue date: 06/17/2013
From: Clark J
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RBG-47367
Download: ML13175A253 (5)


Text

Entergy-Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61 N St. Francisville, LA 70775 Tel 225-381-4177 Joseph A. Clark Manager-Licensing June 17, 2013 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 RBG-47367 RBF1-13-0076

Subject:

Submittal of Owner's Activity Report Form (OAR-i)

River Bend Station - Unit 1 Docket No. 50-458 License No. NPF-47 Pursuant to ASME Code Case N-532-4, please find enclosed the River Bend Station (RBS)

Cycle 17 Owner's Activity Report Form (OAR-i). This report reflects ASME Section XI program activities occurring between February 2011, and March 2013.

If you have any questions or require further information, please contact Ms. Angela Cockrum, at (225) 381-4841.

JAC/wjf fkQ 7r

Submittal of OAR-1 Form RBG-47367 Page 2 of 2 cc:

U.S. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.

Arlington, TX 76011-4511 NRC Resident Inspector PO Box 1050 St. Francisville, LA 70775 Central Records Clerk Public Utility Commission of Texas 1701 N. Congress Ave.

Austin, TX 78711-3326 Mr. Alan Wang, Project Manager U.S. Nuclear Regulatory Commission MS O-8B1 11555 Rockville Pike Rockville, MD 20852-2738

CASES OF ASME BOILER AND PRESSURE VESSEL CODE FORM OAR-1 OWNERS ACTIVITY REPORT Report Number Cycle 17/ Refueling Outage RF-17 OAR-1 Plant River Bend Station, 5485 U.S. Highway 61, St. Francisville, Louisiana 70775 Unit No.

1 (If applicable)

Commercial service date 06/16/1986 Refueling outage no.

RF-17 Current inspection interval 3T Inspection Interval

( 1*,2-, 3 ro 4 -, other)

Current inspection period 2" Inspection Period

( 181,2n, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans 2001 Edition with 2003 Addenda Date and revision of inspection plans CEP-ISI-103 R/2 - 1/17/2011, SEP-ISI-RBS001 RO0- 2/14/2013 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans N/A Code Cases used:

N-532-4 (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl; and (c) the repair/replacement activities and evaluations supporting the completion of RF-17 conform to the requirements of Section XI.

(reF*uling outage number)

Signed w.ro CDate Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Louisiana and employed by HSB CT of Hartford CT have inspected the items described in this Owner's Activity Report and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in Accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/

replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

./Wg Commissions LA 1184 (A,N,I)

Inspector's Signature National Board, State, Province, and Endorsements Date

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE I ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number ISTD-5200 CSL-PSSP-3000-Al Snubber failed to Snubber failed the as-found running meet criteria of ISTD-5200 functional test.

drag load test. Snubber rebuilt and reinstalled.

IWF-2500 CSH-PSSP2042A2 Snubber was E-bar evaluated in CR-RBS-2013-replaced with incorrect E-bar.

3657 and determined to be acceptable.

IWF-2500 SWP-PSSP1186A3 Snubber was E-bar evaluated in CR-RBS-2013-replaced with incorrect E-bar.

3657 and determined to be acceptable.

CASES OF ASME BOILER AND PRESSURE VESSEL CODE TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Class Item Description Description of Date Repair/Replacement Work Completed Plan Number