PNP 2025-016, Annual Radiological Environmental Operating Report
| ML25086A095 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 03/27/2025 |
| From: | Noval W Holtec Palisades |
| To: | Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| PNP 2025-016 | |
| Download: ML25086A095 (1) | |
Text
HOLTEC PALISADES PNP 2025-016 March 27, 2025 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket Nos. 50-255 and 72-007 27780 Blue Star Highway, Covert, MI 49043 Technical Specification 5.6.2 Renewed Facility Operating License No. DPR-20
Reference:
Holtec Decommissioning International, LLC letter to U.S. Nuclear Regulatory Commission, Application for Order Consenting to Transfer of Control of License and Approving Conforming License Amendments, dated December 6, 2023 (ADAMS Accession No. ML23340A161)
Subject:
Annual Radiological Environmental Operating Report In accordance with the requirements of Palisades Nuclear Plant (PNP) Defueled Technical Specifications Section 5.6.2, Radiological Environmental Operating Report, Holtec1 on behalf of Holtec Palisades, LLC (Holtec Palisades) is submitting the 2024 Radiological Environmental Operating Report for PNP. The report was prepared in accordance with the requirements of Title 10 of the Code of Federal Regulations Part 50, Appendix I,Section IV.Band 1 V.C. The period covered by the enclosed report is January 1, 2024, through December 31, 2024.
This letter contains no new and no revised regulatory commitments.
Should you have any questions or require additional information, please contact Amy Filbrandt, Acting Regulatory Assurance Manager at (269) 764-2520.
Respectfully, William Naval William Noval Digitally signed by William Noval DN: cn=William Naval, o=HDI, ou=Regulatory Affairs, email=w.noval@holtec.com Date: 2025.03.27 09:32:00 -04'00' Director Regulatory Affairs Holtec Decommissioning International, LLC 1 Holtec Palisades, LLC ("Holtec Palisades") is the licensed owner of PNP. Holtec Decommissioning International, LLC ("HDI") is the licensed operator of PNP while the facility is in decommissioning.
Pursuant to the license transfer application submitted in connection with the PNP restart (Reference),
licensed authority will transfer from HDI to Palisades Energy, LLC ("Palisades Energy") upon NRC's approval of the transition from decommissioning back to power operations. Holtec Palisades will remain the licensed owner of PNP.
PNP 2025-016 Page 2 of 2
Enclosure:
Annual Radiological Environmental Operating Report cc:
NRC Region Ill Regional Administrator NRC Decommissioning Inspector - Palisades Nuclear Plant NRC NMSS Project Manager - Palisades Nuclear Plant American Nuclear Insurers (ANI)
Enclosure to PNP 2025-016 Annual Radiological Environmental Operating Report
HOLTEC PA LI ADES Plant: Palisades Document Number: 2025-016 Page 1 of 98 YEAR: 2024 Annual Radiological Environmental Operating Report
Plant: Palisades Year: 2024 I
Page 2 of 98 Annual Radiological Environmental Operating Report TABLE OF CONTENTS 1.0 EXECUTIVE
SUMMARY
............................................................................................................. 3
2.0 INTRODUCTION
........................................................................................................................4 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS...................... 5 4.0 INTERPRETATION AND TRENDS OF RESULTS.................................................................... 12 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
.......................... 17 ATTACHMENTS - Sample Deviations........................................................................................................ 21 - Sample Locations......................................................................................................... 22 - REMP Sample Results................................................................................................. 26 - lnterlaboratory Comparison Program Results............................................................... 94 - ERRATA Data.............................................................................................................. 97
1.0 1.1
1.2 Plant
Palisades Year: 2024 I
Page 3 of 98 Annual Radiological Environmental Operating Report EXECUTIVE
SUMMARY
Radiological Environmental Monitoring Program The Annual Radiological Environmental Operating Report presents data obtained through analyses of environmental samples collected for Palisades Radiological Environmental Monitoring Program (REMP) for the period January 1 through December 31, 2024. This report fulfills the requirements of Palisades Technical Specification 5.6.2.
No measurable levels of radiation above baseline levels attributable to Palisades operation were detected in the vicinity of Palisades in 2024. The 2024 REMP thus substantiated the adequacy of source control and effluent monitoring at Palisades with no observed impact on the environment from plant operations.
Palisades established the REMP prior to the station becoming operational to provide data on background radiation and radioactivity normally present in the area.
Palisades has continued to monitor the environment by sampling a variety of environmental media as well as measuring direct radiation. All analyses have required nuclide specific lower limit of detections (LLDs) which must be achieved.
The requirements of the REMP are formally described in the offsite dose calculation manual (ODCM), a site-specific regulatory document. The REMP was modified in 2023, which is discussed in more detail in Section 1.4.
The REMP includes sampling at indicator and control locations. The REMP utilizes indicator locations near the site to determine if any increases of radioactivity has occurred due to station operation and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. Palisades personnel compare indicator results with control and preoperational results to assess any impact Palisades operation might have had on the surrounding environment.
In 2024, REMP samples were collected for radiological analysis. The results of indicator locations were compared with control locations and previous studies. All 2024 REMP results support the conclusion that the surrounding environment is not adversely affected by Palisades' radiological effluents. No activity in any REMP sample from 2024 was attributed to Palisades' radiological effluents.
Reporting Levels No samples equaled or exceeded reporting levels.
1.3 Sample Deviations During 2024, environmental sampling was performed for five media types (airborne, surface water, drinking water, sediment, and fish) and analyzed for radionuclides. All REMP samples were obtained and analyzed in accordance with the Offsite Dose Calculation Manual (ODCM) in 2024.
1.4 2.0 2.1
2.2 Plant
Palisades Year: 2024 I
Page 4 of 98 Annual Radiological Environmental Operating Report Program Modifications There was only one ( 1) program modification made in 2024. The control air sample (GR10) was lost due to the vendor not supporting the maintenance and sample change out. This occurred at the end of November. A new control location was established (12) at the Palisades Emergency Operating Facility in Benton Harbor.
This loss resulted in a loss of 2 weekly air samples for this location which is documented in Attachment 1. This is in alignment with NUREG-1301 with the update to the ODCM in progress.
INTRODUCTION Radiological Environmental Monitoring Program Palisades established the REMP, as defined in the ODCM, to fulfill the requirements of 10 CFR Part 50 Appendix I Section IV.B.2. The REMP supplements the radiological effluent monitoring program by verifying that the concentrations of radioactive materials and levels of radiation found in the environment surrounding the plant are consistent with the effluent measurements and the modeling of the environmental exposure pathways.
Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by Palisades ODCM. These requirements are also listed in this report in Table 1 through Table 4.
Section 4.0 of this report provides a discussion of 2024 sampling results and Section 5.0 providing a summary of results for the monitored exposure pathways.
2.3 Land Use Census Palisades conducts a land use census annually to identify exposure pathways and changes in uses of land within 5 miles of the site from the previous year that might require modifications to the REMP and the ODCM. The purpose of this census is to identify critical receptor pathways for the purpose of effluent modeling and REMP sampling.
Plant: Palisades I
Year: 2024 Page 5 of 98 Annual Radiological Environmental Operating Report 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS Table 1, Exposure Pathway-Airborne Requirement Sample Point Description Distance and Sampling and Type and Frequency of Analyses Direction Collection Frequency Six (6) samples total:
AS (0.595 miles NE) - onsite near state park Continuous sampler Gross beta radioactivity analysis weekly for Four (4) samples from within 6 km (3.7 miles)
A 19 (0.423 miles SSE) - onsite near Bluestar operation with sample each filter change.
collection every week, or of the site boundary in different sectors.
Hwy more frequently if required Gamma isotopic analysis quarterly for a One (1) sample from the vicinity of a A9 (1.525 miles SSW) - offsite near blue star by dust loading.
composite of all filters collected.
community having the highest calculated highway IF filter gross beta is greater than 10 times annual average ground level deposition factor.
A4 (3.882 miles SE) - offsite in Covert the yearly mean of the control sample THEN gamma isotopic is performed on the filter.
One (1) control sample in the least prevalent township wind direction (considering practical direction and distance). Geographic location is A5 (3.590 miles ESE) - offsite in Covert depicted in Figure 2 and Figure 3.
township A 10 (50. 765 miles NE) - offsite near Grand Rapids.
Plant: Palisades I
Year: 2024 Page 6 of 98 Annual Radiological Environmental Operating Report Table 2, Exposure Pathway - Direct Radiation Requirement Sample Point Description Distance and Sampling and Type and Frequency of Analyses Direction Collection Frequency TLD-1 (0.213 miles E) - onsite inner ring TLD TLD-8 (0.602 miles NE)- inner ring TLD TLD-13 (0.530 miles NNE)- inner ring TLD TLD-14 (0.551 miles NE)- inner ring TLD TLD-15 (0.834 miles ENE)- inner ring TLD Twenty-one (21) TLD routine monitoring TLD-16 (0.804 miles E)- inner ring TLD stations either with two or more dosimeters or with one instrument for measuring and TLD-17 (0.572 miles ESE) - inner ring TLD recording dose rate continuously, placed as TLD-18 (0.469 miles SE)- inner ring TLD follows:
TLD-19 (0.443 miles SSE)- inner ring TLD Quarterly Gamma dose (units of milliRoentgen, abbreviated One (1) onsite TLD in the vicinity of the facility.
mR) quarterly An inner ring of stations consisting of one (1)
TLD-20 (0.412 miles S)- inner ring TLD in each overland meteorological sector in the TLD-21 (0.382 miles SSW) - inner ring TLD general area of the site boundary and one ( 1) additional location near the State Park TLD-2 (5.560 miles S) - outer ring TLD camping area in the NE sector.
TLD-3 (5.684 miles SSE) - outer ring TLD An outer ring of stations one (1) in each TLD-4-21 (3.882 miles SE) - outer ring TLD overland meteorological sector within the 12-km range from the site.
TLD-5-21 (3.590 miles ESE) - outer ring TLD One (1) control TLD between 25 and 55 miles TLD-6 (5.314 miles NE)- outer ring TLD from the site. Geographic location is depicted in Figure 2 and Figure 3.
TLD-7 (4.115 miles NNE) - outer ring TLD TLD-9-21 (1.525 miles SSW) - outer ring TLD TLD-23 (3.189 miles ENE) - outer ring TLD TLD-24 (6.021 miles E) - outer ring TLD TLD-11-21 (28.72 miles E)- control TLD
Plant: Palisades I
Year: 2024 Page 7 of 98 Annual Radiological Environmental Operating Report Table 3, Exposure Pathwa, - Waterborne Requirement Sample Point Description Distance and Sampling and Type and Frequency of Analyses Direction Collection Frequency Facility lake water inlet Composite over 1-month Lake (surface)
Gamma isotopic, Gross beta and tritium, monthly 1 sample from control location (Ludington) period 1 sample of South Haven drinking water supply Lake (drinking) 1 sample from a control location (Ludington)
Composite over 1-month Gamma isotopic, Gross beta and tritium, monthly period 1 sample from the Domestic on-site water supply 1 sample from shoreline near Van Buren State Sediment Park Semiannually Gamma Isotopic, semiannually 1 sample south of plant Table 3, Exposure Pathway - Ingestion (Fish)
Requirement Sample Point Description Distance and Sampling and Type and Frequency of Analyses Direction Collection Frequency Sample two (2) species of commercially The indicator sample is obtained from Lake Semiannually Gamma isotopic analysis semiannually and/or recreationally important species in Michigan onsite within a few hundred feet of the the vicinity of the plant discharge area.
main liquid discharge point.
One (1) sample of the same species in The control sample is obtained from Lake areas not influenced by plant discharge.
Michigan near Ludington Ml (201 km North of Palisades).
Plant: Palisades Year: 2024 I
Page 8 of 98 Annual Radiological Environmental Operating Report Figure 1, Exposure Pathway GASEOUS EFFLUENT c>
0
'O 0 *
~
0 NUCLEAR POWER PLANT
~
LIQUID EFFLUENT
/
o.,m I I lrrildi tion
~
L TRANSPORT Exposure pathways to man
Plant: Palisades Year: 2024 I
Page 9 of 98 Annual Radiological Environmental Operating Report Figure 2, Air Sample Locations Benton Heights l!ake Michigan Beach Go gle My Maps 31 0 8 (State Park) co 19 (WalkingTrail) q:i, 0 9 (Township Park) 0 5 (Rood)
Coven... 4 (Covert)
Jericho Corners Wes Control sample (A 10) located at Consumers Energy in Grand Rapids, MI. and was discontinued in December 2024 and replaced with 12 (EOF).
Plant: Palisades Year: 2024 I
Page 10 of 98 Annual Radiological Environmental Operating Report Figure 3, Inner Ring TLD Locations N
NNE r
NNW o,
E ESE SE
Plant: Palisades Year: 2024 Annual Radiological Environmental Operating Report Figure 4, Outer Ring TLD Locations NNW NE ENE SE 2
SSE I
Page 11 of 98
Plant: Palisades Year: 2024 I
Page 12 of 98 Annual Radiological Environmental Operating Report 4.0 INTERPRETATION AND TRENDS OF RESULTS 4.1 Air Particulate Sample There were 316 air samples collected and analyzed for gross beta during 2024. Air particulate samples are collected weekly from six (6) air-sampling locations, five (5) of which are indicator locations and one (1) is a control location. During the weekly collection, an "as found" and "as left" leak test is performed at each station. Weekly samples are sent to Teledyne Brown Engineering Environmental Services for analysis.
Analysis of the airborne particulate sample data, between the five (5) near-site indicator locations and the control location, validates that the surrounding environment is not adversely affected by Palisades' radiological effluents. The average concentration of gross beta activity among all indicator locations was 2.43E-02 pCi/m3 and was 2.41 E-02 pCi/m3 for the control location. Gamma isotopic analysis is performed quarterly on a quarterly composite of the weekly filter papers. All radionuclides detected were naturally occurring radionuclides which are not attributed to plant radiological effluents.
Palisades' pre-operational environmental study showed naturally occurring gross beta radiation between 0.03 and 3.0 pCi/m 3 with a similar trend between stations onsite, in the surrounding community, and control stations. The activity results from 2024 indicate there is no measurable change between pre-operational airborne gross beta activity and present day airborne gross beta activity.
In the absence of plant-related gamma radionuclides, gross beta activity is attributed to naturally occurring radionuclides. The air sample results collected in accordance with the REMP support the conclusions of the effluents monitoring program for 2024. This conclusion is that the surrounding environment is not adversely affected by Palisades' radiological effluents. No REMP air samples from 2024 contained measurable radiological materials attributed to Palisades' radiological effluents.
Plant: Palisades Year: 2024 I
Page 13 of 98 Annual Radiological Environmental Operating Report 4.2 Thermoluminescent Dosimetry (TLD) Sample Results Palisades reports measured radiation dose as net exposure (subtracting control reading) normalized to 91 days. TLDs are oriented in an inner ring, outer ring, and a control location. The inner ring consists of 11 TLDs, the outer ring consists of nine (9)
TLDs, and there is one (1) control location. This orientation allows for monitoring all nine (9) overland compass sectors surrounding Palisades. To assess the effect of direct and shine radiation from Palisades to the environment, each location is compared to a baseline of historical data which was created from a comprehensive review of results from January 2019 through December 2023 for each location. A result outside three (3) standard deviations of the historical mean is indicative of dose attributed to operation of the plant and a follow-up investigation is performed to evaluate the cause.
At the beginning of the third quarter, the transient dose was performed differently than the previous two quarters. Previously, a vault study was performed, and a daily dose was calculated and attributed to the dose received during shipment (transient). At the beginning of the fourth quarter 2024, the vault study dosimeters were sent with the new field dosimeters as usual but were immediately sent back with the third quarter field dosimeters after being changed out to account for dose received during shipment to and from the vendor. This is more representative of the dose received during transient and resulted in significantly lower dose than the previous calculated daily dose. As a result, the net exposure was lower in the 3rd and 4th quarters than the first two quarters. During 2024, none of the TLD values indicated a dose attributed to Palisades plant operation or activities.
During 2021, four additional locations were added (identified as 4-21, 5-21, 9-21, and 11-21) to establish a new baseline at these locations. Starting in the first quarter of 2022, locations 4, 5, 9, 10, 11, and 12 were discontinued and locations 4-21, 5-21, 9-21, and 11-21 were implemented into the program. Essentially this resulted in a relocation of three of the outer ring TLDs, a relocation of one of the control TLDs, and a discontinuation of two control TLDs. All changes made were in accordance with the ODCM and the ODCM change process (technical specification 5.5.1 c.). As a result, these locations do not have a full five (5) years of historical data in which to create a baseline.
TLD measurements taken as part of Palisades' pre-operational environmental study used different instrumentation, which had difficulty in achieving desired sensitivity and accuracy. A more sensitive type of TLD was implemented in 1971 and the present day TLD device used is the industry standard. TLD data has trended consistently throughout the several most recent independent spent fuel storage installation (ISFSI) loading campaigns which indicates that these loading campaigns have had no measurable effect on the environment.
Plant: Palisades Year: 2024 I
Page 14 of 98 Annual Radiological Environmental Operating Report 4.3 Waterborne Sample Results 4.3.1 Surface Water 4.3.2 During 2024 Palisades implemented the REMP in accordance with the ODCM for collection of surface and drinking. For all surface and drinking water samples the same control location is used as a baseline for comparison. That control sample location is referred to as the "Ludington Control" and is collected 125 miles (201 km) north of Palisades. The Ludington Control sample is analyzed monthly and is a composite of daily samples. The Ludington Control sample is analyzed for gamma, tritium, and gross beta activity. In 2024 the only radionuclide activity detected in Ludington Control water was naturally occurring isotopes. Of the twelve (12)
Ludington Control samples collected in 2024, five (5) contained detectable gross beta with an average value of 3.08 pCi/L. The gross beta activity is a result of naturally occurring radionuclides and is not attributed to Palisades' radiological effluents.
The indicator surface water samples collected and analyzed for the REMP include "Lake In" water. This sample is Lake Michigan water after it has traveled through the Palisades' intake structure and traveling screens. This sample is collected daily and composited into a monthly sample which is analyzed for gamma radionuclide and tritium weekly onsite. This sample is also analyzed by Teledyne Brown Engineering Environmental Services for gamma, tritium, and gross beta activity monthly. All radionuclides detected were naturally occurring and are not attributed to Palisades' effluents. Five (5) out of the twelve (12) monthly samples contained measurable gross beta with the average detectable gross beta activity at 4.36 pCi/L. The gross beta activity is attributed to naturally occurring radionuclide.
Palisades' pre-operational environmental study established a baseline of gross beta activity for the site before Palisades was operational. The study results for surface water showed consistently measurable results for gross beta activity between 11 - 18
(+/- 5) pCi/L.
The surface water sample results collected in accordance with the REMP are consistent with the calculations and methodologies of the effluents monitoring program for 2024. The results indicate that the surrounding environment is not adversely affected by Palisades' radiological effluents. No REMP surface water samples from 2024 contained measurable radiological materials attributed to Palisades' effluents.
Drinking Water The indicator drinking water samples collected and analyzed for the REMP include "Domestic Water" and "South Haven Drinking Water". All samples are analyzed for gamma isotopic, tritium, and gross beta by Teledyne Brown Engineering Environmental Services.
Plant: Palisades Year: 2024 I
Page 15 of 98 Annual Radiological Environmental Operating Report Domestic Water is collected onsite from a potable water system. This sample is collected daily and composited into a monthly sample which is analyzed for gamma radionuclide and tritium onsite. All radionuclides detected were naturally occurring and are not attributed to Palisades' radiological effluents. Four (4) out of the twelve
( 12) monthly samples contained measurable gross beta activity with the average detectable gross beta activity at 2.93 pCi/L. The gross beta activity is attributed to naturally occurring radionuclide. Domestic water is not required by the ODCM for the REMP. This sample is collected as part of the NRC bulletin 80-10 commitments and is included in this report because the data strengthens the REMP.
South Haven Drinking Water is collected from the City of South Haven Water Treatment facility located in South Haven, Ml. All radionuclides detected were naturally occurring and are not attributed to Palisades' radiological effluents. Eight (8) out of the twelve ( 12) monthly samples contained measurable gross beta with the average detectable gross beta activity at 2.82 pCi/L. The gross beta activity is attributed to naturally occurring radionuclide.
Palisades' pre-operational environmental study established a baseline of gross beta activity for the site before Palisades was operational. The study results relied upon as a baseline of surface water and gross beta activity between 11 - 18 (+/- 5) pCi/L.
The drinking water sample results collected, in accordance with the REMP, support the conclusions of the effluents monitoring program for 2024. This conclusion is that the surrounding environment is not affected by Palisades' radiological effluents.
4.3.3 Well Water Palisades samples one (1) offsite well water location. This sample is not required by Palisades' ODCM but is procedurally implemented to strengthen the program overall.
The REMP well water sample is collected offsite from a neighboring community and is identified as, "Palisades Park Commercial Well Water". This sample is collected once per month as a grab sample from a community just south of Palisades while the facility is operational (summer months). This sample is analyzed for gamma, tritium, and gross beta activity by Teledyne Brown Engineering Environmental Services. In 2024, no radionuclides were detected in this sample, including tritium. One (1) out of the five (5) monthly samples contained measurable gross beta with the average detectable gross beta activity at 4.60 pCi/L. The gross beta activity is attributed to naturally occurring radionuclide. Sampling was performed from May through September 2024.
Palisades' pre-operational environmental study established a baseline of gross beta activity for the site before Palisades was operational. The study results were that five well water samples from Palisades contained gross beta activity above 5 pCi/L with the highest value being 16 pCi/L.
The well water sample results collected in accordance with the REMP support the conclusions of the effluents monitoring program for 2024. This conclusion is that the surrounding environment is not adversely affected by Palisades' radiological effluents.
No REMP well water samples from 2024 contained measurable radiological materials attributed to Palisades' radiological effluents.
Plant: Palisades Year: 2024 I
Page 16 of 98 Annual Radiological Environmental Operating Report 4.4 Sediment Sample Results 4.5 Sediment samples are collected two (2) times per year, north and south of the plant from the beach on Lake Michigan. One sample is collected at the southern edge of the property and a second sample is collected approximately 0.5 miles north of the plant at Van Buren State Park. The sample south of the plant is not required by the ODCM but is collected and analyzed to strengthen the REMP. Both the north and south sediment samples are analyzed for gamma radionuclides. In 2024, only naturally occurring radioisotopes were detected, which are not attributed to Palisades' radiological effluents. In accordance with the ODCM, no control sample is collected for this sample type.
Soil samples were not specifically part of the Palisades' pre-operational environmental study, however a soil study of Cs-137 was performed by Palisades in 2011 (due to global events such as historical atomic testing and fallout). Analysis was performed of soil in the surrounding area (Southwest Michigan) which showed Cs-137 concentrations between 1.41 E-08 uCi/g and 5.68E-07 uCi/g with an average of 2.68E-07 uCi/g. Considering similar studies performed by other utilities, a conservative (low) background of 1.8E-07 uCi/g Cs-137 in soil is assumed to be due to global fallout.
The sediment sample results collected in accordance with the REMP support the conclusions of the effluents monitoring program for 2024. This conclusion is that the surrounding environment is not adversely affected by Palisades' radiological effluents.
Ingestion Sample Results Fish Sample Results Indicator and Control fish samples are collected and analyzed twice per year. The filet of the fish is shipped to a vendor and analyzed for gamma radionuclides. The indicator fish are collected near Palisades lake-out discharge point. At least two (2) species of commercial or recreational importance are collected and analyzed. At least one (1) sample of the same species is collected as a control sample. The control fish are collected 201 km north of Palisades near Ludington, Ml. In 2024, the only radionuclides detected among all fish samples were naturally occurring radionuclides which were not attributed to Palisades' radiological effluents.
Palisades' pre-operational environmental study established a baseline for radiological material in fish. The study established that gross beta activity is generally between 2 and 4 pCi/g and gross gamma activity is generally between 0.04 and 0.4 pCi/g in fish.
Cs-137 and Sr-90 were measured in the pre-operational study and were expected to be measured due to known worldwide contamination from historical global atomic testing. Cs-137 detected was generally between 0.10 and 0.25 pCi/g and Sr-90 detected was generally between 0.01 to 0.04 pCi/g in the pre-operational environmental study.
The fish sample results collected in accordance with the REMP support the conclusions of the effluents monitoring program for 2024. This conclusion is that the surrounding environment is not adversely affected by Palisades' radiological effluents.
Plant: Palisades Year: 2024 I
Page 17 of 98 Annual Radiological Environmental Operating Report 4.6 Land Use Census Results 4.7 The latest land use census (performed in August 2024) did not identify any changes that would prompt a change to the REMP or ODCM. The method used to perform the census was in accordance with the ODCM and site procedures. The sectors in Table 5 include all overland compass sectors.
In accordance with the REMP, the census was restricted to 2.5 miles after it was confirmed that the existing cow and goat in the ESE sector would be the critical receptor (for dose modeling purposes). Even if a cow or goat were identified greater than 2.5 miles from Palisades in the other sectors, the nearer goat and cow would be used (due to the higher consequence) to calculate dose to the public.
Table 5, Closest Receptor by Sector Sector Direction Garden (miles)
Cow (miles)
Goat (miles) 2 NNE 2.44
> 2.5
> 2.5 3
NE 2.74
> 2.5
> 2.5 4
ENE 3.95 2.29
> 2.5 5
E N/A 3.51 3.46 6
ESE 2.43 2.04 2.04 7
SE 2.20 3.88 3.88 8
SSE 0.70
> 2.5
> 2.5 9
s N/A
> 2.5
> 2.5 10 SSW N/A
> 2.5
> 2.5 lnterlaboratory Comparison Results contains a summary of the results for the lnterlaboratory Comparison program for Teledyne Brown Engineering Environmental Services.
5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
Table 6, Radiological Environmental Monitoring Program Summary, summarizes data for the 2024 REMP program.
Plant: Palisades I
Year: 2024 I Page 18 of 98 Annual Radiological Environmental Operating Report Table 6, Radiological Environmental Monitoring Program Summary Indicator Locations Location [Note 31 Control Number of Sample Type Type/ Number LLD [Note 1]
Mean (F)[Note 2]
[Highest Mean (F)[Note 2]
Locations Mean Reportable (Units) of Analyses
[Range]
Annual Mean]
[Range]
(F)[Note 2] [Range]
Occurrences
[Note 4]
2.62E-02 GB/ 316 0.01 2.43E-02 (265/265)
Station A4 (52/52) 2.41E-02 (51/51) 0 Air (pCi/m3)
[1.17E 4.17E-02]
(3.882 mi. SE)
[1.17E [1.21 E 4.1 ?E-02]
4.67E-02]
1-131 /24 0.07
<MDA (0/20)
N/A N/A
<MDA (0/4) 0 Cs-134 / 24 0.05
<MDA (0/20)
N/A N/A
<MDA (0/4) 0 Cs-137 / 24 0.06
<MDA (0/20)
N/A N/A
<MDA (0/4) 0 Direct Gamma I 84 Sensitivity of 3 7.13 (80/80) 2 10.92 (4/4) 8.63 (4/4)
Radiation mR
[2.36 - 13.57]
(5.56 mi S)
[8.39 - 3.57]
[5.69-11.77]
0 (mR/Qtr)
Gross Beta/ 24 4.0 4.36 (5 I 12)
Lake In (Plant 4.36 (5 I 12) 3.08 (5 I 12) 0
[2.88 - 5.15]
Lake intake)
[2.88 - 5.15]
[2.34 - 3.88]
H-3 / 24 2000
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Mn-54 / 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Fe-59 / 24 30
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Co-58 I 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Surface Water Co-60 I 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 (pCi/L)
Zn-65 I 24 30
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Zr-95 / 24 30
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Nb-95 / 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Cs-134 / 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Cs-137/24 18
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 Ba-140 / 24 60
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0 La-140 / 24 15
<MDA (0 / 12)
N/A N/A
<MDA (0 / 12) 0
Plant: Palisades I
Year: 2024 I Page 19 of 98 Annual Radiological Environmental Operating Report Table 6, Radiological Environmental Monitoring Program Summary Indicator Locations Location [Note 31 Control Number of Sample Type Type/ Number LLD [Note 1]
Mean (F)[Note 2]
[Highest Mean (F)[Note 2]
Locations Mean Reportable (Units) of Analyses
[Range]
Annual Mean]
[Range]
(F)[Note 2] [Range]
Occurrences
[Note 4]
Gross Beta/ 36 4
2.86 (12 / 24)
Domestic 2.93 (4 I 12) 3.08 (5 / 12) 0
[2.46 -3.40]
Water (On-site)
[2.64 - 3.40]
[2.34 - 3.88]
H-3 / 36 2000
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Mn-54 / 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Fe-59 / 36 30
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Co-58 I 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Drinking Water Co-60 I 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 (pCi/L)
Zn-65 I 36 30
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Zr-95 I 36 30
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Nb-95 / 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Cs-134 / 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Cs-137 / 36 18
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Ba-140 / 36 60
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 La-140 / 36 15
<MDA (0 / 24)
N/A N/A
<MDA (0 / 12) 0 Mn-54 / 9 130
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Fe-59 / 9 260
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Co-58 I 9 130
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Fish (pCi/kg)
Co-60 I 9 130
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Zn-65 I 9 260
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Cs-134 / 9 130
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0 Cs-137 / 9 150
<MDA (0 / 6)
N/A N/A
<MDA (0 / 3) 0
Plant: Palisades I
Year: 2024 I Page 20 of 98 Annual Radiological Environmental Operating Report Table 6, Radiological Environmental Monitoring Program Summary Indicator Locations Location [Note 31 Control Number of Sample Type Type/ Number LLD [Note 1]
Mean (F)[Note 2]
[Highest Mean (F)[Note 2]
Locations Mean Reportable (Units) of Analyses
[Range]
Annual Mean]
[Range]
(F)[Note 2] [Range]
Occurrences
[Note 4]
Sediment Cs-134 I 4 150
<MDA (0 / 4)
N/A N/A Control sample not 0
(North)
(pCi/ka)
Cs-137 I 4 180
<MDA (0 / 4)
N/A N/A required 0
Gross Beta/ 5 4
4.60 (1/ 5)
Palisades Park 4.60 (1 / 5) 0
[4.60]
Commercial
[4.60]
Well (0.7 mi. S)
H-3 / 5 2000
<MDA (0 / 5)
N/A N/A 0
Mn-54 / 5 15
<MDA (0 / 5)
N/A N/A 0
Offsite Well Fe-59 I 5 30
<MDA (0 / 5)
N/A N/A 0
Water (Pal Co-58 I 5 15
<MDA (0 / 5)
N/A N/A Control sample not 0
Park Co-60 I 5 15
<MDA (0 / 5)
N/A N/A required 0
Commercial Zn-65 I 5 30
<MDA (0 / 5)
N/A N/A 0
Well) (pCi/L)
Zr-95 / 5 30
<MDA (0 / 5)
N/A N/A 0
Nb-95 / 5 15
<MDA (0 / 5)
N/A N/A 0
Cs-134 I 5 15
<MDA (0 / 5)
N/A N/A 0
Cs-137 I 5 18
<MDA (0 / 5)
N/A N/A 0
Ba-140 / 5 60
<MDA (0 / 5)
N/A N/A 0
La-140 / 5 15
<MDA (0 I 5)
N/A N/A 0
[Note 1] - LLD= Required lower limit of detection
[Note 2] - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).
[Note 3] - Locations are specified (1) by name and (2) compass sector relative to reactor site.
[Note 4] - A reportable occurrence is a situation in which an NRC report was submitted in accordance with the requirements in Palisades ODCM.
Comment No.
Sample Media Affected
~issed Samples 1
AP Sample Anomalies 1
AP 2
TLD 3
AP 4
WT/WO Plant: Palisades I
Year: 2024 Page 21 of 98 Annual Radiological Environmental Operating R~ort Page 1 of 1 Sample Location GR10 GR10 2
5PR Domestic Water/
Lake In/
SHRAW Date 11/25/24-12/9/24 10/17/24-11/5/24 4/16/2024 6/10/2024 10/1/2023 Sample Deviations Problem Grand Rapids (Control) air sample location was lost due to resources to exchange and manage the equipment by an outside unaffiliated company.
Facility lost power to a section due to a short in an underground feed.
TLD #2 found on the ground approximately 5 feet from the hanging location.
Air sample station 5PR was found not running.
Monthly composite water REMP water samples for October 2023 were not analyzed in time to meet La-140 LLD requirement. This was not discovered until 6/19/24 Evaluation/ Actions A new control air sample location was identified and established ( 12) at the Palisades Emergency Operating Facility (EOF) on 12/9/2024. Data from DC Cook is available for use if needed.
The air sampler was operated using a portable generator and thus had lower than usual total flow for the week as a result. The underground feed to the building that controls the air sample was repaired on 11/5/24.
The TLD was sent to the vendor for analysis and the new quarterly TLD was hung.
Troubleshooting resolved the issue and power was restored on 6/11/24.
Samples were collected and composited as required by the ODCM but shipment to the vendor for analysis was delayed. The required LLD for La-140 is 15 pCi/L and the MDC range of the three samples were:
20.15 and 20.31 pCi/L.
Plant: Palisades I
Year: 2024 J
Page 22 of 98 Annual Radiological Environmental Operating Report Page 1 of 4 Sample Locations Station Code
- Air Part Lake Milk Food Sediment TLD Fish Ground Water Location Water Products 1
ST Palisades Nuclear Plant Onsite, on tree near NW corner of bag X
crew bldg.
1 ST Palisades Nuclear Plant Plant discharge area.
X X
2 TH RR 3 Coloma TLD located on Becht Road, west side on post, 50 yards south of 48th Ave.
X 5.6 miles S 3
HS 76182 48th Ave. Covert Along 48th Ave, 1/4 mile west of 76th St.
In barnyard 50 yds off north side of road.
X 5.8 miles SSE 4
JS 36th Avenue, 1/2 miles South side of road. TLD is in air sample X
X east of M-140 station housing.
5 PR 72723 CR 378 Covert Along CR 378, 3/4 mile east of M-140, 30 3-1 /2 miles ESE ft off north side of road. TLD is in air sample station housing.
X X
6 RB RR 3 South Haven Along 12th Ave (CR 384), turn NW past 4-1/2 miles NE Maple Grove, go 1/4 mile located in X
orchard on north side of road.
7 SN21 Emergency Siren 21 On Monroe Blvd, at corner of 76th and 11th Street.
X 4.1 miles NNE 8
SP State Park 1 mile N Onsite near State Park boundary, on side X
X of road as road turns west.
9 TP Covert Township Park Along 32nd Ave, 1/4 mile west of Blue 1.5 miles SSW Star Hwy. 5 ft off south side of road. TLD X
X is in air sample station housing.
10 GR Grand Rapids, Ml 55 Grand Rapids Service Center, in storage X
miles NNE (RETIRED) area. Air sample on west side near shed.
Plant: Palisades I
Year: 2024 J
Page 23 of 98 Annual Radiological Environmental Operating Report Page 2 of 4 Sample Locations Station Air Part Lake Milk Food Sediment TLD Fish Ground Water Code Location Water Products 11 KZ Kalamazoo, Ml 29 mi.
10523 Almena Drive Kalamazoo.
X E
Emergency Operating 12 Facility 330 W. Main St. Benton Harbor X
SSW Perimeter of Palisades Past #8 along dirt road, west up dune path 13 ST X
NNE at right of containment test structure Perimeter of Palisades 25 yards of east of Station #34 between 14 ST X
NE State Park and DFS Building.
Perimeter of Palisades North along Blue Star Hwy, 0.75 miles 15 ST from access road, 10 ft off west side of X
E road.
Perimeter of Palisades North along Blue Star Hwy, 0.4 miles from 16 ST X
E access road, 50 ft off west side of road.
Perimeter of Palisades Along access road, 25 yds south of 17 ST southern power line, 15 yds off east side X
ESE of road.
Perimeter of Palisades 20 yds from access road along south 18 ST X
SE road. 40 yds off south road.
Plant: Palisades I
Year: 2024 J
Page 24 of 98 Annual Radiological Environmental Operating Report Page 3 of 4 Sample Locations Station Air Part Lake Milk Food Sediment TLD Fish Ground Water Code Location Water Products Perimeter of Palisades 0.2 miles along south road from access 19 ST road, 30 ft off north side of road. TLD 30 X
X SSE ft off south side of road.
Perimeter of Palisades 0.4 miles along south road from access 20 ST X
s road, 20 ft off south side of road.
Perimeter of Palisades 0.7 miles along south road from access 21 ST road, just past top of hill. Near Lake X
22 PW Palisades Warehouse Control TLD in lead cave.
X Emergency Siren 19 23 SN19 3 mi.
On CR 380.
X ENE Emergency Siren 26 24 SN26 6mi On 67th Street.
X E
South Haven, Ml 25 SH 5-1 /2 mi South Haven Water Treatment Plant.
X NNE 30 STN 1/2 mile N of discharge X
N 31 STS South site boundary Beach at the south site boundary.
X s
Ludington Pumped 32 LP Storage 125 Mi X
X N
Plant: Palisades I
Year: 2024 J
Page 25 of 98 Annual Radiological Environmental Operating Report Page 4 of 4 Sample Locations Station Air Part Lake Milk Food Sediment TLD Fish Ground Water Code Location Water Products Palisades Park 47 pp South of Plant.
X s
- Distances listed in Code/Location are approximate.
Plant: Palisades I
Year: 2024 I Page 26 of 98 Annual Radiological Environmental Operating Report Page 1 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRl0 1/2/2024 9:00 1/8/2024 10:00 328.5 CU.M GR-B 0.0262 0.00349 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 1/8/202414:05 308.6 CU.M GR-B 0.0228 0.00421 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 1/8/2024 13:30 280.3 CU.M GR-B 0.0232 0.00465 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 1/8/2024 13:50 337 CU.M GR-B 0.0234 0.00386 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 1/8/202414:15 288.8 CU.M GR-B 0.0259 0.00451 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 1/8/2024 14:25 271.8 CU.M GR-B 0.0253 0.00479 pCi/cu m Air Particulate Filters GRlO 1/8/2024 10:00 1/16/2024 14:30 455.9 CU.M GR-B 0.0189 0.003 pCi/cu m Air Particulate Filters 8SP 1/8/2024 13:30 1/15/2024 12:42 342.6 CU.M GR-B 0.0243 0.00335 pCi/cu m Air Particulate Filters 19ST 1/8/2024 13:50 1/15/2024 12:57 390.8 CU.M GR-B 0.0254 0.00294 pCi/cu m Air Particulate Filters 9TP 1/8/2024 14:05 1/15/202413:17 348.3 CU.M GR-B 0.0197 0.0033 pCi/cu m Air Particulate Filters 4JS 1/8/2024 14:15 1/15/2024 13:34 331.3 CU.M GR-B 0.0264 0.00347 pCi/cu m Air Particulate Filters 5PR 1/8/2024 14:25 1/15/2024 13:42 243.5 CU.M GR-B 0.0328 0.0047 pCi/cu m Air Particulate Filters 8SP 1/15/2024 12:42 1/22/2024 13:45 334.1 CU.M GR-B 0.0251 0.0041 pCi/cu m Air Particulate Filters 19ST 1/15/2024 12:57 1/22/2024 14:05 402.1 CU.M GR-B 0.0226 0.0034 pCi/cu m Air Particulate Filters 9TP 1/15/202413:17 1/22/2024 14:20 351.1 CU.M GR-B 0.0239 0.0039 pCi/cu m Air Particulate Filters 4JS 1/15/2024 13:34 1/22/2024 14:35 342.6 CU.M GR-B 0.0267 0.00399 pCi/cu m Air Particulate Filters 5PR 1/15/2024 13:42 1/22/2024 14:45 325.6 CU.M GR-B 0.0307 0.0042 pCi/cu m
Plant: Palisades Year: 2024 Page 27 of 98 Annual Radiological Environmental Operating Report Page 2 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 1/16/2024 14:30 1/22/2024 9:00 328.5 CU.M GR-B 0.0288 0.0035 pCi/cu m Air Particulate Filters GRlO 1/22/2024 9:00 1/29/2024 8:40 376.6 CU.M GR-B 0.0138 0.00316 pCi/cu m Air Particulate Filters 8SP 1/22/2024 13:45 1/29/2024 12:45 334.1 CU.M GR-B 0.015 0.00345 pCi/cu m Air Particulate Filters 19ST 1/22/2024 14:05 1/29/2024 13:00 379.4 CU.M GR-B 0.0138 0.00304 pCi/cu m Air Particulate Filters 9TP 1/22/2024 14:20 1/29/2024 13:20 331.3 CU.M GR-B 0.0168 0.00348 pCi/cu m Air Particulate Filters 4JS 1/22/2024 14:35 1/29/2024 13:30 322.8 CU.M GR-B 0.0185 0.00357 pCi/cu m Air Particulate Filters 5PR 1/22/2024 14:45 1/29/2024 13:42 226.5 CU.M GR-B 0.0237 0.00507 pCi/cu m Air Particulate Filters GRlO 1/29/2024 8:40 2/5/2024 13:30 393.6 CU.M GR-B 0.0251 0.00253 pCi/cu m Air Particulate Filters 8SP 1/29/2024 12:45 2/5/202414:04 322.8 CU.M GR-B 0.0204 0.00369 pCi/cu m Air Particulate Filters 19ST 1/29/2024 13:00 2/5/202414:17 390.8 CU.M GR-B 0.0174 0.00305 pCi/cu m Air Particulate Filters 9TP 1/29/2024 13:20 2/5/2024 14:35 342.6 CU.M GR-B 0.0159 0.00348 pCi/cu m Air Particulate Filters 4JS 1/29/2024 13:30 2/5/2024 14:43 331.3 CU.M GR-B 0.0162 0.0036 pCi/cu m Air Particulate Filters 5PR 1/29/2024 13:42 2/5/2024 14:49 297.3 CU.M GR-B 0.0231 0.00402 pCi/cu m Air Particulate Filters GR10 2/5/2024 13:30 2/13/2024 9:00 421.9 CU.M GR-B 0.0195 0.00248 pCi/cu m Air Particulate Filters 8SP 2/5/2024 14:04 2/12/2024 13:45 334.1 CU.M GR-B 0.0257 0.00299 pCi/cu m Air Particulate Filters 19ST 2/5/202414:17 2/12/2024 14:00 370.9 CU.M GR-B 0.0253 0.00269 pCi/cu m Air Particulate Filters 9TP 2/5/2024 14:35 2/12/2024 14: 15 331.3 CU.M GR-B 0.0279 0.00301 pCi/cu m Air Particulate Filters 4JS 2/5/2024 14:43 2/12/2024 14:25 322.8 CU.M GR-B 0.0266 0.00309 pCi/cu m Air Particulate Filters 5PR 2/5/2024 14:49 2/12/2024 14:35 226.5 CU.M GR-B 0.0318 0.00439 pCi/cu m
Plant: Palisades Year: 2024 Page 28 of 98 Annual Radiological Environmental Operating Report Page 3 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 2/12/2024 13:45 2/20/2024 13:45 370.9 CU.M GR-B 0.024 0.00282 pCi/cu m Air Particulate Filters 19ST 2/12/2024 14:00 2/20/2024 14:00 433.2 CU.M GR-B 0.0222 0.00241 pCi/cu m Air Particulate Filters 9TP 2/12/2024 14:15 2/20/2024 14: 15 390.8 CU.M GR-B 0.0205 0.00267 pCi/cu m Air Particulate Filters 4JS 2/12/2024 14:25 2/20/2024 14:27 379.4 CU.M GR-B 0.0243 0.00276 pCi/cu m Air Particulate Filters 5PR 2/12/2024 14:35 2/20/2024 14:35 339.8 CU.M GR-B 0.0245 0.00308 pCi/cu m Air Particulate Filters GR10 2/13/2024 9:00 2/19/2024 8:07 328.5 CU.M GR-B 0.0259 0.00331 pCi/cu m Air Particulate Filters GR10 2/19/2024 8:07 2/26/2024 13:00 390.8 CU.M GR-B 0.0322 0.00279 pCi/cu m Air Particulate Filters 8SP 2/20/2024 13:45 2/26/2024 13:15 286 CU.M GR-B 0.0328 0.00381 pCi/cu m Air Particulate Filters 19ST 2/20/2024 14:00 2/26/2024 13:25 317.1 CU.M GR-B 0.0317 0.00344 pCi/cu m Air Particulate Filters 9TP 2/20/202414:15 2/26/2024 13:35 286 CU.M GR-B 0.0246 0.00381 pCi/cu m Air Particulate Filters 4JS 2/20/2024 14:27 2/26/2024 13:43 277.5 CU.M GR-B 0.0331 0.00392 pCi/cu m Air Particulate Filters 5PR 2/20/2024 14:35 2/26/2024 13:48 192.5 CU.M GR-B 0.0377 0.00564 pCi/cu m Air Particulate Filters GR10 2/26/2024 13:00 3/4/2024 8:04 365.3 CU.M GR-B 0.0255 0.0032 pCi/cu m Air Particulate Filters 8SP 2/26/202413:15 3/4/202412:17 311.5 CU.M GR-B 0.0222 0.00349 pCi/cu m Air Particulate Filters 19ST 2/26/2024 13:25 3/4/202412:31 370.9 CU.M GR-B 0.0234 0.00294 pCi/cu m Air Particulate Filters 9TP 2/26/2024 13:35 3/4/2024 13:24 337 CU.M GR-B 0.0282 0.00323 pCi/cu m Air Particulate Filters 4JS 2/26/2024 13:43 3/4/2024 13:35 325.6 CU.M GR-B 0.0276 0.00334 pCi/cu m Air Particulate Filters 5PR 2/26/2024 13:48 3/4/202413:45 288.8 CU.M GR-B 0.032 0.00377 pCi/cu m Air Particulate Filters GR10 3/4/2024 8:04 3/11/2024 9:25 376.6 CU.M GR-B 0.0174 0.00309 pCi/cu m
Plant: Palisades Year: 2024 Page 29 of 98 Annual Radiological Environmental Operating Report Page 4 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 3/4/202412:17 3/11/2024 13:30 334.1 CU.M GR-B 0.0149 0.0035 pCi/cu m Air Particulate Filters 19ST 3/4/202412:31 3/11/2024 13:55 368.1 CU.M GR-B 0.0137 0.00318 pCi/cu m Air Particulate Filters 9TP 3/4/2024 13:24 3/11/2024 14:05 334.1 CU.M GR-B 0.0191 0.0035 pCi/cu m Air Particulate Filters 4JS 3/4/2024 13:35 3/11/2024 14:20 320 CU.M GR-B 0.0189 0.00366 pCi/cu m Air Particulate Filters 5PR 3/4/2024 13:45 3/11/202414:30 220.9 CU.M GR-B 0.0195 0.00529 pCi/cu m Air Particulate Filters GRl0 3/11/2024 9:25 3/18/2024 10:00 376.6 CU.M GR-B 0.0211 0.00363 pCi/cu m Air Particulate Filters 8SP 3/11/2024 13:30 3/18/2024 12:40 314.3 CU.M GR-B 0.0245 0.00371 pCi/cu m Air Particulate Filters 19ST 3/11/2024 13:55 3/18/2024 13:00 368.1 CU.M GR-B 0.0257 0.00317 pCi/cu m Air Particulate Filters 9TP 3/11/202414:05 3/18/202413:15 337 CU.M GR-B 0.0222 0.00346 pCi/cu m Air Particulate Filters 4JS 3/11/2024 14:20 3/18/2024 13:30 322.8 CU.M GR-B 0.029 0.00361 pCi/cu m Air Particulate Filters 5PR 3/11/2024 14:30 3/18/2024 13:40 283.2 CU.M GR-B 0.0274 0.00412 pCi/cu m Air Particulate Filters GRlO 3/18/2024 10:00 3/25/2024 8:00 379.4 CU.M GR-B 0.0199 0.00289 pCi/cu m Air Particulate Filters 8SP 3/18/2024 12:40 3/25/2024 13:40 342.6 CU.M GR-B 0.0198 0.00399 pCi/cu m Air Particulate Filters 19ST 3/18/2024 13:00 3/25/2024 13:53 379.4 CU.M GR-B 0.0204 0.00361 pCi/cu m Air Particulate Filters 9TP 3/18/202413:15 3/25/2024 14:03 345.5 CU.M GR-B 0.0132 0.00396 pCi/cu m Air Particulate Filters 4JS 3/18/2024 13:30 3/25/2024 14: 14 328.5 CU.M GR-B 0.0206 0.00416 pCi/cu m Air Particulate Filters 5PR 3/18/2024 13:40 3/25/2024 14:23 223.7 CU.M GR-B 0.0211 0.00611 pCi/cu m Air Particulate Filters GRlO 3/25/2024 8:00 4/1/2024 8:00 376.6 CU.M GR-B 0.0204 0.0032 pCi/cu m Air Particulate Filters 8SP 3/25/2024 13:40 4/1/2024 13:48 317.1 CU.M GR-B 0.0235 0.00346 pCi/cu m
Plant: Palisades Year: 2024 Page 30 of 98 Annual Radiological Environmental Operating Report Page 5 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 19ST 3/25/2024 13:53 4/1/202414:00 373.8 CU.M GR-B 0.0222 0.00293 pCi/cu m Air Particulate Filters 9TP 3/25/2024 14:03 4/1/202414:13 342.6 CU.M GR-B 0.0205 0.0032 pCi/cu m Air Particulate Filters 4JS 3/25/202414:14 4/1/2024 14:22 328.5 CU.M GR-B 0.0272 0.00333 pCi/cu m Air Particulate Filters 5PR 3/25/2024 14:23 4/1/2024 14:32 286 CU.M GR-B 0.0245 0.00383 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 4/8/2024 8:30 379.4 CU.M GR-B 0.0121 0.00265 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 4/8/202413:15 334.1 CU.M GR-B 0.0139 0.00361 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 4/8/202413:00 365.3 CU.M GR-B 0.0123 0.00331 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 4/8/2024 12:40 334.1 CU.M GR-B 0.0117 0.00361 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 4/8/2024 11:45 317.1 CU.M GR-B 0.0117 0.00381 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 4/8/2024 12:20 220.9 CU.M GR-B 0.0188 0.00546 pCi/cu m Air Particulate Filters GRlO 4/8/2024 8:30 4/15/2024 7:45 368.1 CU.M GR-B 0.0174 0.0032 pCi/cu m Air Particulate Filters 4JS 4/8/202411:45 4/15/2024 12:52 280.3 CU.M GR-B 0.0264 0.00359 pCi/cu m Air Particulate Filters 5PR 4/8/2024 12:20 4/15/2024 12:58 280.3 CU.M GR-B 0.0262 0.00359 pCi/cu m Air Particulate Filters 9TP 4/8/2024 12:40 4/15/2024 12:40 334.1 CU.M GR-B 0.0187 0.00301 pCi/cu m Air Particulate Filters 19ST 4/8/2024 13:00 4/15/2024 12:27 362.4 CU.M GR-B 0.0198 0.00278 pCi/cu m Air Particulate Filters 8SP 4/8/202413:15 4/15/202412:15 305.8 CU.M GR-B 0.0203 0.00328 pCi/cu m Air Particulate Filters GRl0 4/15/2024 7:45 4/22/2024 8:30 370.9 CU.M GR-B 0.0189 0.00296 pCi/cu m Air Particulate Filters 8SP 4/15/202412:15 4/23/202412:47 379.4 CU.M GR-B 0.0142 0.00311 pCi/cu m Air Particulate Filters 19ST 4/15/2024 12:27 4/23/2024 12:58 419.1 CU.M GR-B 0.0175 0.00281 pCi/cu m
Plant: Palisades Year: 2024 Page 31 of 98 Annual Radiological Environmental Operating Report Page 6 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 4/15/2024 12:40 4/23/202413:11 382.3 CU.M GR-B 0.0203 0.00309 pCi/cu m Air Particulate Filters 4JS 4/15/2024 12:52 4/23/2024 13:22 314.3 CU.M GR-B 0.0202 0.00375 pCi/cu m Air Particulate Filters 5PR 4/15/2024 12:58 4/23/2024 13:29 421.9 CU.M GR-B 0.0123 0.00279 pCi/cu m Air Particulate Filters GR10 4/22/2024 8:30 4/29/2024 7:30 368.1 CU.M GR-B 0.024 0.00304 pCi/cu m Air Particulate Filters 8SP 4/23/202412:47 4/29/2024 13:04 269 CU.M GR-B 0.0265 0.00408 pCi/cu m Air Particulate Filters 19ST 4/23/2024 12:58 4/29/2024 13:55 314.3 CU.M GR-B 0.0267 0.00349 pCi/cu m Air Particulate Filters 9TP 4/23/202413:11 4/29/2024 14: 10 294.5 CU.M GR-B 0.0249 0.00372 pCi/cu m Air Particulate Filters 4JS 4/23/2024 13:22 4/29/2024 14:20 240.7 CU.M GR-B 0.0323 0.00455 pCi/cu m Air Particulate Filters 5PR 4/23/2024 13:29 4/29/2024 14:25 234.2 CU.M GR-B 0.0283 0.00469 pCi/cu m Air Particulate Filters GR10 4/29/2024 7:30 5/6/2024 8:25 368.1 CU.M GR-B 0.0184 0.00247 pCi/cu m Air Particulate Filters 8SP 4/29/2024 13:04 5/6/2024 13:28 322.8 CU.M GR-B 0.0157 0.00346 pCi/cu m Air Particulate Filters 19ST 4/29/2024 13:55 5/6/202413:58 356.8 CU.M GR-B 0.0184 0.00313 pCi/cu m Air Particulate Filters 9TP 4/29/202414:10 5/6/2024 14: 10 334.1 CU.M GR-B 0.014 0.00335 pCi/cu m Air Particulate Filters 4JS 4/29/2024 14:20 5/6/2024 14:20 277.5 CU.M GR-B 0.0237 0.00402 pCi/cu m Air Particulate Filters 5PR 4/30/2024 14:55 5/6/2024 14:28 263.4 CU.M GR-B 0.0194 0.00425 pCi/cu m Air Particulate Filters GRlO 5/6/2024 8:25 5/13/2024 7:30 362.4 CU.M GR-B 0.0175 0.00298 pCi/cu m Air Particulate Filters 8SP 5/6/2024 13:28 5/13/2024 13:21 308.6 CU.M GR-B 0.0214 0.00294 pCi/cu m Air Particulate Filters 19ST 5/6/2024 13:58 5/13/2024 13:33 362.4 CU.M GR-B 0.0165 0.00251 pCi/cu m Air Particulate Filters 9TP 5/6/2024 14:10 5/13/2024 13:46 342.6 CU.M GR-B 0.0188 0.00265 pCi/cu m
Plant: Palisades Year: 2024 Page 32 of 98 Annual Radiological Environmental Operating Report Page 7 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 4JS 5/6/2024 14:20 5/13/2024 13:54 317.1 CU.M GR-B 0.0213 0.00287 pCi/cu m Air Particulate Filters 5PR 5/6/2024 14:28 5/13/2024 14:00 334.1 CU.M GR-B 0.0186 0.00272 pCi/cu m Air Particulate Filters GR10 5/13/2024 7:30 5/20/2024 7:45 359.6 CU.M GR-B 0.0201 0.00354 pCi/cu m Air Particulate Filters 8SP 5/13/2024 13:21 5/20/2024 13:07 320 CU.M GR-B 0.022 0.00337 pCi/cu m Air Particulate Filters 19ST 5/13/2024 13:33 5/20/2024 13:22 351.1 CU.M GR-B 0.0205 0.00308 pCi/cu m Air Particulate Filters 9TP 5/13/2024 13:46 5/20/2024 13:41 337 CU.M GR-B 0.0225 0.0032 pCi/cu m Air Particulate Filters 4JS 5/13/2024 13:54 5/20/2024 13:50 305.8 CU.M GR-B 0.0207 0.00353 pCi/cu m Air Particulate Filters 5PR 5/13/2024 14:00 5/20/2024 13:55 260.5 CU.M GR-B 0.0242 0.00414 pCi/cu m Air Particulate Filters GR10 5/20/2024 7:45 5/28/202412:15 421.9 CU.M GR-B 0.0198 0.00299 pCi/cu m Air Particulate Filters 8SP 5/20/2024 13:07 5/28/2024 10:25 339.8 CU.M GR-B 0.0173 0.00374 pCi/cu m Air Particulate Filters 19ST 5/20/2024 13:22 5/28/2024 10:45 402.1 CU.M GR-B 0.0152 0.00317 pCi/cu m Air Particulate Filters 9TP 5/20/2024 13:41 5/28/202411:05 385.1 CU.M GR-B 0.0163 0.00331 pCi/cu m Air Particulate Filters 4JS 5/20/2024 13:50 5/28/202411:15 354 CU.M GR-B 0.0207 0.0036 pCi/cu m Air Particulate Filters 5PR 5/20/2024 13:55 5/28/2024 11:25 370.9 CU.M GR-B 0.0164 0.00343 pCi/cu m Air Particulate Filters 8SP 5/28/2024 10:25 6/3/2024 10:35 277.5 CU.M GR-B 0.0185 0.00454 pCi/cu m Air Particulate Filters 19ST 5/28/2024 10:45 6/3/202410:50 303 CU.M GR-B 0.027 0.00416 pCi/cu m Air Particulate Filters 9TP 5/28/2024 11:05 6/3/202411:05 288.8 CU.M GR-B 0.0251 0.00437 pCi/cu m Air Particulate Filters 4JS 5/28/202411:15 6/3/202411:15 269 CU.M GR-B 0.0237 0.00469 pCi/cu m Air Particulate Filters 5PR 5/28/2024 11:25 6/3/2024 11:25 220.9 CU.M GR-B 0.0225 0.00571 pCi/cu m
Plant: Palisades Year: 2024 Page 33 of 98 Annual Radiological Environmental Operating Report Page 8 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 5/28/2024 12:15 6/3/2024 8:10 294.5 CU.M GR-B 0.021 0.00351 pCi/cu m Air Particulate Filters GRlO 6/3/2024 8: 10 6/10/2024 9:00 359.6 CU.M GR-B 0.0161 0.00365 pCi/cu m Air Particulate Filters 8SP 6/3/2024 10:35 6/10/2024 10:30 303 CU.M GR-B 0.0169 0.00341 pCi/cu m Air Particulate Filters 19ST 6/3/2024 10:50 6/10/2024 10:45 354 CU.M GR-B 0.0166 0.00292 pCi/cu m Air Particulate Filters 9TP 6/3/202411:05 6/10/2024 11:05 342.6 CU.M GR-B 0.0184 0.00302 pCi/cu m Air Particulate Filters 4JS 6/3/2024 11:15 6/10/202411:15 311.5 CU.M GR-B 0.0206 0.00332 pCi/cu m Air Particulate Filters 5PR 6/3/2024 11:25 6/10/202411:25 99.1 CU.M GR-B 0.0387 0.0104 pCi/cu m Air Particulate Filters GRlO 6/10/2024 9:00 6/17/202413:00 362.4 CU.M GR-B 0.0184 0.00379 pCi/cu m Air Particulate Filters 8SP 6/10/2024 10:30 6/17/202413:01 322.8 CU.M GR-B 0.022 0.00407 pCi/cu m Air Particulate Filters 19ST 6/10/2024 10:45 6/17/202413:23 356.8 CU.M GR-B 0.0198 0.00368 pCi/cu m Air Particulate Filters 9TP 6/10/202411:05 6/17/202413:37 337 CU.M GR-B 0.0191 0.0039 pCi/cu m Air Particulate Filters 4JS 6/10/202411:15 6/17/202413:46 311.5 CU.M GR-B 0.0245 0.00421 pCi/cu m Air Particulate Filters 5PR 6/10/202411:25 6/17/202413:55 220.9 CU.M GR-B 0.0301 0.00594 pCi/cu m Air Particulate Filters GRl0 6/17/202413:00 6/24/2024 8:45 339.8 CU.M GR-B 0.0325 0.00357 pCi/cu m Air Particulate Filters 8SP 6/17/202413:01 6/24/2024 13:27 297.3 CU.M GR-B 0.0281 0.00462 pCi/cu m Air Particulate Filters 19ST 6/17/202413:23 6/24/2024 13:42 351.1 CU.M GR-B 0.028 0.00391 pCi/cu m Air Particulate Filters 9TP 6/17/202413:37 6/24/2024 13:59 337 CU.M GR-B 0.0187 0.00407 pCi/cu m Air Particulate Filters 4JS 6/17/202413:46 6/24/2024 14:08 308.6 CU.M GR-B 0.026 0.00444 pCi/cu m Air Particulate Filters 5PR 6/17/202413:55 6/24/2024 14:14 314.3 CU.M GR-B 0.0226 0.00437 pCi/cu m
Plant: Palisades Year: 2024 Page 34 of 98 Annual Radiological Environmental Operating Report Page 9 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 6/24/2024 8:45 7/1/2024 7:30 351.1 CU.M GR-B 0.0176 0.00317 pCi/cu m Air Particulate Filters 8SP 6/24/2024 13:27 7/1/202410:45 314.3 CU.M GR-B 0.0173 0.00386 pCi/cu m Air Particulate Filters 19ST 6/24/2024 13:42 7/1/202411:15 345.5 CU.M GR-B 0.0165 0.0035 pCi/cu m Air Particulate Filters 9TP 6/24/2024 13:59 7/1/2024 11:35 331.3 CU.M GR-B 0.0185 0.00366 pCi/cu m Air Particulate Filters 4JS 6/24/2024 14:08 7/1/202411:45 303 CU.M GR-B 0.0221 0.004 pCi/cu m Air Particulate Filters 5PR 6/24/202414:14 7/1/202411:50 252 CU.M GR-B 0.0201 0.00481 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 7/8/2024 8:30 356.8 CU.M GR-B 0.0232 0.00331 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 7/8/202411:45 300.1 CU.M GR-B 0.0216 0.0037 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 7/8/202411:58 356.8 CU.M GR-B 0.0199 0.00311 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 7/8/202412:14 342.6 CU.M GR-B 0.0181 0.00324 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 7/8/202412:30 311.5 CU.M GR-B 0.0239 0.00356 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 7/8/202412:38 317.1 CU.M GR-B 0.025 0.00351 pCi/cu m Air Particulate Filters GRlO 7/8/2024 8:30 7/15/2024 8:00 339.8 CU.M GR-B 0.015 0.0036 pCi/cu m Air Particulate Filters 8SP 7/8/202411:45 7/15/202411:55 314.3 CU.M GR-B 0.0233 0.00377 pCi/cu m Air Particulate Filters 19ST 7/8/202411:58 7/15/202412:07 348.3 CU.M GR-B 0.0195 0.0034 pCi/cu m Air Particulate Filters 9TP 7/8/202412:14 7/15/202412:28 331.3 CU.M GR-B 0.0234 0.00357 pCi/cu m Air Particulate Filters 4JS 7/8/202412:30 7/15/202412:38 303 CU.M GR-B 0.0241 0.0039 pCi/cu m Air Particulate Filters 5PR 7/8/202412:38 7/15/202412:45 254.8 CU.M GR-B 0.027 0.00464 pCi/cu m Air Particulate Filters GR10 7/15/2024 8:00 7/22/2024 9:00 365.3 CU.M GR-B 0.0254 0.00306 pCi/cu m
Plant: Palisades Year: 2024 Page 35 of 98 Annual Radiological Environmental Operating Report Page 10 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 7/15/202411:55 7/22/202413:40 300.1 CU.M GR-B 0.019 0.00408 pCi/cu m Air Particulate Filters 19ST 7/15/202412:07 7/22/202413:55 359.6 CU.M GR-B 0.0176 0.0034 pCi/cu m Air Particulate Filters 9TP 7/15/202412:28 7/22/202414:08 348.3 CU.M GR-B 0.019 0.00352 pCi/cu m Air Particulate Filters 4JS 7/15/202412:38 7/22/2024 14: 19 314.3 CU.M GR-B 0.0242 0.0039 pCi/cu m Air Particulate Filters 5PR 7/15/202412:45 7/22/202414:30 317.1 CU.M GR-B 0.0211 0.00386 pCi/cu m Air Particulate Filters GRlO 7/22/2024 9:00 7/29/2024 7:00 348.3 CU.M GR-B 0.023 0.00315 pCi/cu m Air Particulate Filters 8SP 7/22/202413:40 7/29/202412:20 311.5 CU.M GR-B 0.0254 0.00358 pCi/cu m Air Particulate Filters 19ST 7/22/202413:55 7/29/202412:37 348.3 CU.M GR-B 0.0206 0.00321 pCi/cu m Air Particulate Filters 9TP 7/22/202414:08 7/29/202412:52 334.1 CU.M GR-B 0.0195 0.00334 pCi/cu m Air Particulate Filters 4JS 7/22/202414:19 7/29/202413:03 305.8 CU.M GR-B 0.0255 0.00365 pCi/cu m Air Particulate Filters 5PR 7/22/2024 14:30 7/29/202413:10 254.8 CU.M GR-B 0.0276 0.00437 pCi/cu m Air Particulate Filters GRlO 7/29/2024 7:00 8/5/2024 7:00 351.1 CU.M GR-B 0.0276 0.00374 pCi/cu m Air Particulate Filters 8SP 7/29/202412:20 8/5/2024 13:45 297.3 CU.M GR-B 0.0289 0.00369 pCi/cu m Air Particulate Filters 19ST 7/29/202412:37 8/5/202413:57 354 CU.M GR-B 0.029 0.0031 pCi/cu m Air Particulate Filters 9TP 7/29/202412:52 8/5/202414:17 328.5 CU.M GR-B 0.0335 0.00333 pCi/cu m Air Particulate Filters 4JS 7/29/202413:03 8/5/2024 14:27 305.8 CU.M GR-B 0.0353 0.00358 pCi/cu m Air Particulate Filters 5PR 7/29/202413:10 8/5/2024 14:33 308.6 CU.M GR-B 0.0378 0.00355 pCi/cu m Air Particulate Filters GRlO 8/5/2024 7:00 8/12/2024 7:00 356.8 CU.M GR-B 0.0159 0.00313 pCi/cu m Air Particulate Filters 8SP 8/5/2024 13:45 8/12/2024 10:55 308.6 CU.M GR-B 0.0204 0.00425 pCi/cu m
Plant: Palisades Year: 2024 Page 36 of 98 Annual Radiological Environmental Operating Report Page 11 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 19ST 8/5/2024 13:57 8/12/202411:20 345.5 CU.M GR-B 0.0146 0.0038 pCi/cu m Air Particulate Filters 9TP 8/5/202414:17 8/12/202411:35 334.1 CU.M GR-B 0.0156 0.00393 pCi/cu m Air Particulate Filters 4JS 8/5/2024 14:27 8/12/2024 11:50 303 CU.M GR-B 0.0189 0.00433 pCi/cu m Air Particulate Filters 5PR 8/5/2024 14:33 8/12/2024 12:00 254.8 CU.M GR-B 0.0188 0.00515 pCi/cu m Air Particulate Filters GRlO 8/12/2024 7:00 8/19/2024 6:00 348.3 CU.M GR-B 0.023 0.0036 pCi/cu m Air Particulate Filters 8SP 8/12/2024 10:55 8/19/2024 10:50 294.5 CU.M GR-B 0.0281 0.00379 pCi/cu m Air Particulate Filters 19ST 8/12/2024 11:20 8/19/2024 11:08 354 CU.M GR-B 0.0256 0.00316 pCi/cu m Air Particulate Filters 9TP 8/12/2024 11:35 8/19/2024 11:22 342.6 CU.M GR-B 0.0265 0.00326 pCi/cu m Air Particulate Filters 4JS 8/12/202411:50 8/19/202411:43 314.3 CU.M GR-B 0.0295 0.00356 pCi/cu m Air Particulate Filters 5PR 8/12/2024 12:00 8/19/202411:50 311.5 CU.M GR-B 0.0297 0.00358 pCi/cu m Air Particulate Filters GRlO 8/19/2024 6:00 8/26/2024 8:00 359.6 CU.M GR-B 0.0267 0.00338 pCi/cu m Air Particulate Filters 8SP 8/19/2024 10:50 8/26/2024 12:59 317.1 CU.M GR-B 0.0277 0.00396 pCi/cu m Air Particulate Filters 19ST 8/19/202411:08 8/26/2024 13:12 356.8 CU.M GR-B 0.0273 0.00351 pCi/cu m Air Particulate Filters 9TP 8/19/2024 11:22 8/26/2024 13:30 348.3 CU.M GR-B 0.0204 0.0036 pCi/cu m Air Particulate Filters 4JS 8/19/202411:43 8/26/2024 13:40 311.5 CU.M GR-B 0.0271 0.00402 pCi/cu m Air Particulate Filters 5PR 8/19/202411:50 8/26/2024 13:46 260.5 CU.M GR-B 0.0286 0.00481 pCi/cu m Air Particulate Filters GRl0 8/26/2024 8:00 9/3/2024 8:30 404.9 CU.M GR-B 0.0304 0.00252 pCi/cu m Air Particulate Filters 8SP 8/26/2024 12:59 9/3/2024 13:43 339.8 CU.M GR-B 0.022 0.00358 pCi/cu m Air Particulate Filters 19ST 8/26/2024 13:12 9/3/2024 13:55 404.9 CU.M GR-B 0.0216 0.003 pCi/cu m
Plant: Palisades Year: 2024 Page 37 of 98 Annual Radiological Environmental Operating Report Page 12 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 8/26/2024 13:30 9/3/202414:05 399.3 CU.M GR-B 0.0252 0.00305 pCi/cu m Air Particulate Filters 4JS 8/26/2024 13:40 9/3/202414:13 356.8 CU.M GR-B 0.0243 0.00341 pCi/cu m Air Particulate Filters 5PR 8/26/2024 13:46 9/3/2024 14: 18 356.8 CU.M GR-B 0.0243 0.00341 pCi/cu m Air Particulate Filters GRl0 9/3/2024 8:30 9/9/2024 8:00 305.8 CU.M GR-B 0.0178 0.00406 pCi/cu m Air Particulate Filters 8SP 9/3/2024 13:43 9/9/2024 13:30 269 CU.M GR-B 0.0264 0.00379 pCi/cu m Air Particulate Filters 19ST 9/3/2024 13:55 9/9/2024 13:45 305.8 CU.M GR-B 0.0222 0.00333 pCi/cu m Air Particulate Filters 9TP 9/3/2024 14:05 9/9/202414:05 297.3 CU.M GR-B 0.0225 0.00343 pCi/cu m Air Particulate Filters 4JS 9/3/202414:13 9/9/202414:15 269 CU.M GR-B 0.0258 0.00379 pCi/cu m Air Particulate Filters 5PR 9/3/2024 14: 18 9/9/2024 14:25 223.7 CU.M GR-B 0.0287 0.00455 pCi/cu m Air Particulate Filters GRl0 9/9/2024 8:00 9/16/2024 8:00 354 CU.M GR-B 0.0426 0.00347 pCi/cu m Air Particulate Filters 8SP 9/9/2024 13:30 9/16/2024 14:02 297.3 CU.M GR-B 0.0324 0.00419 pCi/cu m Air Particulate Filters 19ST 9/9/2024 13:45 9/17/2024 9:55 399.3 CU.M GR-B 0.0323 0.00312 pCi/cu m Air Particulate Filters 9TP 9/9/2024 14:05 9/16/2024 14:23 351.1 CU.M GR-B 0.0334 0.00354 pCi/cu m Air Particulate Filters 4JS 9/9/202414:15 9/16/2024 14:32 308.6 CU.M GR-B 0.0357 0.00403 pCi/cu m Air Particulate Filters 5PR 9/9/2024 14:25 9/16/2024 14:38 314.3 CU.M GR-B 0.0358 0.00396 pCi/cu m Air Particulate Filters GRlO 9/16/2024 8:00 9/23/2024 8:00 351.1 CU.M GR-B 0.0363 0.00318 pCi/cu m Air Particulate Filters 8SP 9/16/2024 14:02 9/23/2024 13:05 311.5 CU.M GR-B 0.0347 0.00394 pCi/cu m Air Particulate Filters 9TP 9/16/2024 14:23 9/23/2024 13:29 342.6 CU.M GR-B 0.0366 0.00358 pCi/cu m Air Particulate Filters 4JS 9/16/2024 14:32 9/23/2024 13:37 303 CU.M GR-B 0.0417 0.00406 pCi/cu m
Plant: Palisades Year: 2024 Page 38 of 98 Annual Radiological Environmental Operating Report Page 13 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 9/16/2024 14:38 9/23/2024 13:43 254.8 CU.M GR-B 0.0405 0.00482 pCi/cu m Air Particulate Filters 19ST 9/17/2024 9:55 9/23/202413:16 308.6 CU.M GR-B 0.0386 0.00398 pCi/cu m Air Particulate Filters GRlO 9/23/2024 8:00 9/30/2024 8:00 359.6 CU.M GR-B 0.0235 0.00377 pCi/cu m Air Particulate Filters 8SP 9/23/2024 13:05 9/30/2024 13:45 297.3 CU.M GR-B 0.0253 0.00376 pCi/cu m Air Particulate Filters 19ST 9/23/202413:16 9/30/2024 14:05 359.6 CU.M GR-B 0.0218 0.0031 pCi/cu m Air Particulate Filters 9TP 9/23/2024 13:29 9/30/2024 14: 15 354 CU.M GR-B 0.0297 0.00316 pCi/cu m Air Particulate Filters 4JS 9/23/2024 13:37 9/30/2024 14:25 308.6 CU.M GR-B 0.0265 0.00362 pCi/cu m Air Particulate Filters 5PR 9/23/2024 13:43 9/30/2024 14:35 317.1 CU.M GR-B 0.0268 0.00352 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 10/8/2024 9:57 410.6 CU.M GR-B 0.0247 0.00287 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 10/7/202411:35 314.3 CU.M GR-B 0.0309 0.00433 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 10/7/202411:55 351.1 CU.M GR-B 0.0258 0.00387 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 10/7/202412:10 348.3 CU.M GR-B 0.0167 0.0039 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 10/7/202412:20 305.8 CU.M GR-B 0.0283 0.00444 pCi/cu m Air Particulate Filters 5PR 9/30/2024 14:35 10/7/2024 12:30 260.5 CU.M GR-B 0.0245 0.0052 pCi/cu m Air Particulate Filters 8SP 10/7/202411:35 10/15/202413:15 351.1 CU.M GR-B 0.0244 0.00336 pCi/cu m Air Particulate Filters 19ST 10/7/202411:55 10/15/2024 13:27 421.9 CU.M GR-B 0.0243 0.00279 pCi/cu m Air Particulate Filters 9TP 10/7/202412:10 10/15/2024 13:40 419.1 CU.M GR-B 0.0205 0.00281 pCi/cu m Air Particulate Filters 4JS 10/7/202412:20 10/15/2024 13:48 365.3 CU.M GR-B 0.0248 0.00323 pCi/cu m Air Particulate Filters 5PR 10/7/202412:30 10/15/2024 13:54 370.9 CU.M GR-B 0.0214 0.00318 pCi/cu m
Plant: Palisades Year: 2024 Page 39 of 98 Annual Radiological Environmental Operating Report Page 14 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 10/8/2024 9:57 10/14/2024 8:30 311.5 CU.M GR-B 0.0255 0.00333 pCi/cu m Air Particulate Filters GRlO 10/14/2024 8:30 10/21/2024 7:30 152.9 CU.M GR-B 0.0209 0.00652 pCi/cu m Air Particulate Filters 8SP 10/15/202413:15 10/21/202413:10 274.7 CU.M GR-B 0.0321 0.00378 pCi/cu m Air Particulate Filters 19ST 10/15/2024 13:27 10/21/2024 13:35 314.3 CU.M GR-B 0.0266 0.00331 pCi/cu m Air Particulate Filters 9TP 10/15/2024 13:40 10/21/202413:53 308.6 CU.M GR-B 0.0214 0.00337 pCi/cu m Air Particulate Filters 4JS 10/15/2024 13:48 10/21/202414:07 269 CU.M GR-B 0.0309 0.00387 pCi/cu m Air Particulate Filters 5PR 10/15/2024 13:54 10/21/202414:14 229.4 CU.M GR-B 0.0321 0.00454 pCi/cu m Air Particulate Filters GRlO 10/21/2024 7:30 10/28/2024 7:00 152.9 CU.M GR-B 0.0467 0.0075 pCi/cu m Air Particulate Filters 8SP 10/21/202413:10 10/28/202412:55 339.8 CU.M GR-B 0.0302 0.00293 pCi/cu m Air Particulate Filters 19ST 10/21/2024 13:35 10/28/202413:10 365.3 CU.M GR-B 0.026 0.00273 pCi/cu m Air Particulate Filters 9TP 10/21/202413:53 10/28/2024 13:25 362.4 CU.M GR-B 0.0247 0.00275 pCi/cu m Air Particulate Filters 4JS 10/21/202414:07 10/28/2024 13:35 314.3 CU.M GR-B 0.0334 0.00318 pCi/cu m Air Particulate Filters 5PR 10/21/202414:14 10/28/2024 13:45 356.8 CU.M GR-B 0.0288 0.00279 pCi/cu m Air Particulate Filters GR10 10/28/2024 7:00 11/4/2024 8:00 152.9 CU.M GR-B 0.0461 0.00853 pCi/cu m Air Particulate Filters 8SP 10/28/2024 12:55 11/4/2024 12:20 362.4 CU.M GR-B 0.0342 0.00317 pCi/cu m Air Particulate Filters 19ST 10/28/202413:10 11/4/2024 12:30 362.4 CU.M GR-B 0.0351 0.00317 pCi/cu m Air Particulate Filters 9TP 10/28/2024 13:25 11/4/2024 12:47 359.6 CU.M GR-B 0.0242 0.00319 pCi/cu m Air Particulate Filters 4JS 10/28/2024 13:35 11/4/202412:56 314.3 CU.M GR-B 0.033 0.00366 pCi/cu m Air Particulate Filters 5PR 10/28/2024 13:45 11/4/2024 13:02 288.8 CU.M GR-B 0.0333 0.00397 pCi/cu m
Plant: Palisades Year: 2024 Page 40 of 98 Annual Radiological Environmental Operating Report Page 15 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 11/4/2024 8:00 11/12/2024 8:00 419.1 CU.M GR-B 0.021 0.00283 pCi/cu m Air Particulate Filters 8SP 11/4/202412:20 11/12/202412:36 396.4 CU.M GR-B 0.0219 0.00329 pCi/cu m Air Particulate Filters 19ST 11/4/202412:30 11/12/202412:49 419.1 CU.M GR-B 0.0211 0.00311 pCi/cu m Air Particulate Filters 9TP 11/4/2024 12:47 11/12/2024 13:03 419.1 CU.M GR-B 0.0212 0.00311 pCi/cu m Air Particulate Filters 4JS 11/4/202412:56 11/12/202413:13 365.3 CU.M GR-B 0.0236 0.00357 pCi/cu m Air Particulate Filters 5PR 11/4/202413:02 11/12/202413:20 410.6 CU.M GR-B 0.0173 0.00317 pCi/cu m Air Particulate Filters GRlO 11/12/2024 8:00 11/18/2024 7:00 314.3 CU.M GR-B 0.0245 0.0036 pCi/cu m Air Particulate Filters 8SP 11/12/2024 12:36 11/18/202413:19 317.1 CU.M GR-B 0.0256 0.00375 pCi/cu m Air Particulate Filters 19ST 11/12/202412:49 11/18/202413:29 317.1 CU.M GR-B 0.0254 0.00375 pCi/cu m Air Particulate Filters 9TP 11/12/2024 13:03 11/18/2024 13:44 308.6 CU.M GR-B 0.0276 0.00384 pCi/cu m Air Particulate Filters 4JS 11/12/202413:13 11/18/202413:51 271.8 CU.M GR-B 0.0297 0.00436 pCi/cu m Air Particulate Filters 5PR 11/12/202413:20 11/18/202413:57 254.8 CU.M GR-B 0.0276 0.00466 pCi/cu m Air Particulate Filters GRlO 11/18/2024 7:00 11/25/2024 7:00 370.9 CU.M GR-B 0.0268 0.00306 pCi/cu m Air Particulate Filters 8SP 11/18/202413:19 11/25/202411:30 345.5 CU.M GR-B 0.0285 0.00327 pCi/cu m Air Particulate Filters 19ST 11/18/202413:29 11/25/202411:50 368.1 CU.M GR-B 0.026 0.00307 pCi/cu m Air Particulate Filters 9TP 11/18/202413:44 11/25/202412:05 365.3 CU.M GR-B 0.0253 0.0031 pCi/cu m Air Particulate Filters 4JS 11/18/2024 13:51 11/25/2024 12:20 322.8 CU.M GR-B 0.0256 0.0035 pCi/cu m Air Particulate Filters 5PR 11/18/202413:57 11/25/202412:25 359.6 CU.M GR-B 0.0248 0.00314 pCi/cu m Air Particulate Filters 8SP 11/25/202411:30 12/2/2024 11:20 379.4 CU.M GR-B 0.0239 0.00299 pCi/cu m
Plant: Palisades Year: 2024 Page 41 of 98 Annual Radiological Environmental Operating Report Page 16 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 19ST 11/25/2024 11:50 12/2/202411:40 376.6 CU.M GR-B 0.0222 0.00301 pCi/cu m Air Particulate Filters 9TP 11/25/202412:05 12/2/202411:55 370.9 CU.M GR-B 0.0212 0.00306 pCi/cu m Air Particulate Filters 4JS 11/25/2024 12:20 12/2/202412:10 325.6 CU.M GR-B 0.0288 0.00348 pCi/cu m Air Particulate Filters 5PR 11/25/2024 12:25 12/2/2024 12:20 311.5 CU.M GR-B 0.026 0.00363 pCi/cu m Air Particulate Filters 8SP 12/2/2024 11:20 12/9/2024 13:05 362.4 CU.M GR-B 0.0225 0.00328 pCi/cu m Air Particulate Filters 19ST 12/2/2024 11:40 12/9/2024 13:20 385.1 CU.M GR-B 0.0236 0.00308 pCi/cu m Air Particulate Filters 9TP 12/2/2024 11:55 12/9/2024 13:50 385.1 CU.M GR-B 0.0234 0.00308 pCi/cu m Air Particulate Filters 4JS 12/2/2024 12:10 12/9/2024 14:00 334.1 CU.M GR-B 0.0251 0.00355 pCi/cu m Air Particulate Filters 5PR 12/2/2024 12:20 12/9/2024 14:07 382.3 CU.M GR-B 0.0261 0.00311 pCi/cu m Air Particulate Filters 8SP 12/9/2024 13:05 12/16/2024 13:00 379.4 CU.M GR-B 0.0257 0.00317 pCi/cu m Air Particulate Filters 19ST 12/9/2024 13:20 12/16/202413:15 342.6 CU.M GR-B 0.0278 0.0035 pCi/cu m Air Particulate Filters 9TP 12/9/2024 13:50 12/16/2024 13:37 373.8 CU.M GR-B 0.019 0.00321 pCi/cu m Air Particulate Filters 4JS 12/9/2024 14:00 12/16/2024 13:51 328.5 CU.M GR-B 0.0348 0.00365 pCi/cu m Air Particulate Filters 5PR 12/9/2024 14:07 12/16/202414:01 314.3 CU.M GR-B 0.0241 0.00382 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/16/2024 14:42 385.1 CU.M GR-B 0.0244 0.00312 pCi/cu m Air Particulate Filters 8SP 12/16/2024 13:00 12/23/202411:26 356.8 CU.M GR-B 0.0284 0.00346 pCi/cu m Air Particulate Filters 19ST 12/16/202413:15 12/23/202411:37 342.6 CU.M GR-B 0.0296 0.0036 pCi/cu m Air Particulate Filters 9TP 12/16/2024 13:37 12/23/202411:53 373.8 CU.M GR-B 0.0332 0.0033 pCi/cu m Air Particulate Filters 4JS 12/16/2024 13:51 12/23/2024 12:02 331.3 CU.M GR-B 0.0352 0.00373 pCi/cu m
Plant: Palisades Year: 2024 Page 42 of 98 Annual Radiological Environmental Operating Report Page 17 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 12/16/2024 14:01 12/23/202412:08 376.6 CU.M GR-B 0.0247 0.00327 pCi/cu m Air Particulate Filters 12 12/16/2024 14:42 12/23/2024 7:41 370.9 CU.M GR-B 0.0335 0.00332 pCi/cu m Air Particulate Filters 12 12/23/2024 7:41 12/30/2024 8:07 382.3 CU.M GR-B 0.0346 0.00292 pCi/cu m Air Particulate Filters 8SP 12/23/2024 11:26 12/30/2024 12:33 331.3 CU.M GR-B 0.0358 0.00337 pCi/cu m Air Particulate Filters 19ST 12/23/202411:37 12/30/2024 12:45 342.6 CU.M GR-B 0.0326 0.00325 pCi/cu m Air Particulate Filters 9TP 12/23/202411:53 12/30/202412:58 370.9 CU.M GR-B 0.0289 0.00301 pCi/cu m Air Particulate Filters 4JS 12/23/2024 12:02 12/30/202413:08 325.6 CU.M GR-B 0.0337 0.00342 pCi/cu m Air Particulate Filters 5PR 12/23/2024 12:08 12/30/202413:16 308.6 CU.M GR-B 0.037 0.00361 pCi/cu m
Plant: Palisades Year: 2024 Page 43 of 98 Annual Radiological Environmental Operating Report Page 18 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M BE-7 0.09099 0.03006 pCi/cu m Air Particulate Filters 8SP 1/2/2024 11:15 4/1/2024 13:48 4225 CU.M MN-54
<.00208 0.00208 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M CO-58
<.00281 0.00281 pCi/cu m Air Particulate Filters 8SP 1/2/2024 11:15 4/1/2024 13:48 4225 CU.M FE-59
<.009577 0.009577 pCi/cu m Air Particulate Filters 8SP 1/2/2024 11:15 4/1/2024 13:48 4225 CU.M CO-60
<.001779 0.001779 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M ZN-65
<.0059 0.0059 pCi/cu m Air Particulate Filters 8SP 1/2/2024 11:15 4/1/2024 13:48 4225 CU.M NB-95
<.003126 0.003126 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M ZR-95
<.005712 0.005712 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M 1-131
<.4519 0.4519 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M CS-134
<.002034 0.002034 pCi/cu m Air Particulate Filters 8SP 1/2/2024 11:15 4/1/2024 13:48 4225 CU.M CS-137
<.001386 0.001386 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M BA-140
<.1862 0.1862 pCi/cu m Air Particulate Filters 8SP 1/2/202411:15 4/1/2024 13:48 4225 CU.M LA-140
<.1199 0.1199 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M BE-7 0.0954 0.02191 pCi/cu m Air Particulate Filters 19ST 1/2/202411:26 4/1/2024 14:00 4882 CU.M MN-54
<.001824 0.001824 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M CO-58
<.002287 0.002287 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M FE-59
<.008785 0.008785 pCi/cu m Air Particulate Filters 19ST 1/2/202411:26 4/1/2024 14:00 4882 CU.M CO-60
<.001645 0.001645 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M ZN-65
<.004476 0.004476 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M NB-95
<.003537 0.003537 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M ZR-95
<.004336 0.004336 pCi/cu m Air Particulate Filters 19ST 1/2/202411:26 4/1/2024 14:00 4882 CU.M 1-131
<.3191 0.3191 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M CS-134
<.002124 0.002124 pCi/cu m Air Particulate Filters 19ST 1/2/202411:26 4/1/2024 14:00 4882 CU.M CS-137
<.001674 0.001674 pCi/cu m Air Particulate Filters 19ST 1/2/202411:26 4/1/2024 14:00 4882 CU.M BA-140
<.184 0.184 pCi/cu m Air Particulate Filters 19ST 1/2/2024 11:26 4/1/2024 14:00 4882 CU.M LA-140
<.07517 0.07517 pCi/cu m
Plant: Palisades Year: 2024 Page 44 of 98 Annual Radiological Environmental Operating Report Page 19 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M BE-7 0.09251 0.04368 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M MN-54
<.003547 0.003547 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M CO-58
<.004467 0.004467 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M FE-59
<.01572 0.01572 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M CO-60
<.002536 0.002536 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M ZN-65
<.008416 0.008416 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M NB-95
<.005569 0.005569 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M ZR-95
<.01022 0.01022 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M 1-131
<.6347 0.6347 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M CS-134
<.003006 0.003006 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M CS-137
<.002678 0.002678 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M BA-140
<.2778 0.2778 pCi/cu m Air Particulate Filters 9TP 1/2/2024 10:59 4/1/202414:13 4386 CU.M LA-140
<.1002 0.1002 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M BE-7 0.08501 0.02902 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M MN-54
<.001918 0.001918 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M CO-58
<.002285 0.002285 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M FE-59
<.009293 0.009293 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M CO-60
<.002351 0.002351 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M ZN-65
<.003752 0.003752 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M NB-95
<.00309 0.00309 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M ZR-95
<.005596 0.005596 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M 1-131
<.4224 0.4224 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M CS-134
<.002287 0.002287 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M CS-137
<.001475 0.001475 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M BA-140
<.1731 0.1731 pCi/cu m Air Particulate Filters 4JS 1/2/2024 12:00 4/1/2024 14:22 4222 CU.M LA-140
<.1066 0.1066 pCi/cu m
Plant: Palisades Year: 2024 Page 45 of 98 Annual Radiological Environmental Operating Report Page 20 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M BE-7 0.1171 0.03681 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M MN-54
<.002862 0.002862 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M CO-58
<.004634 0.004634 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M FE-59
<.01326 0.01326 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M CO-60
<.00246 0.00246 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M ZN-65
<.006664 0.006664 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M NB-95
<.003808 0.003808 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M ZR-95
<.006146 0.006146 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M 1-131
<.5983 0.5983 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M CS-134
<.002208 0.002208 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M CS-137
<.002116 0.002116 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M BA-140
<.2766 0.2766 pCi/cu m Air Particulate Filters 5PR 1/2/2024 12:08 4/1/2024 14:32 3426 CU.M LA-140
<.06245 0.06245 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M BE-7 0.07224 0.03182 pCi/cu m Air Particulate Filters GRl0 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M MN-54
<.002276 0.002276 pCi/cu m Air Particulate Filters GRl0 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M CO-58
<.003099 0.003099 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M FE-59
<.01034 0.01034 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M CO-60
<.002029 0.002029 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M ZN-65
<.006337 0.006337 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M NB-95
<.003251 0.003251 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M ZR-95
<.006552 0.006552 pCi/cu m Air Particulate Filters GRl0 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M 1-131
<.5137 0.5137 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M CS-134
<.00157 0.00157 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M CS-137
<.002141 0.002141 pCi/cu m Air Particulate Filters GRl0 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M BA-140
<.2212 0.2212 pCi/cu m Air Particulate Filters GRlO 1/2/2024 9:00 4/1/2024 8:00 4899 CU.M LA-140
<.08004 0.08004 pCi/cu m
Plant: Palisades Year: 2024 Page 46 of 98 Annual Radiological Environmental Operating Report Page 21 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M BE-7 0.1258 0.03678 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M MN-54
<.002803 0.002803 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M CO-58
<.003958 0.003958 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M FE-59
<.01148 0.01148 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M CO-60
<.002885 0.002885 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M ZN-65
<.005695 0.005695 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M NB-95
<.004117 0.004117 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M ZR-95
<.00679 0.00679 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M 1-131
<.678 0.678 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M CS-134
<.002455 0.002455 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M CS-137
<.002468 0.002468 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M BA-140
<.2673 0.2673 pCi/cu m Air Particulate Filters 8SP 4/1/2024 13:48 7/1/2024 10:45 4094 CU.M LA-140
<.1195 0.1195 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M BE-7 0.08244 0.0295 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M MN-54
<.001902 0.001902 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M CO-58
<.003747 0.003747 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M FE-59
<.01035 0.01035 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M CO-60
<.002187 0.002187 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M ZN-65
<.004489 0.004489 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M NB-95
<.002643 0.002643 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M ZR-95
<.004058 0.004058 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M 1-131
<.482 0.482 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M CS-134
<.001732 0.001732 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M CS-137
<.001614 0.001614 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M BA-140
<.2135 0.2135 pCi/cu m Air Particulate Filters 19ST 4/1/2024 14:00 7/1/202411:15 4644 CU.M LA-140
<.09286 0.09286 pCi/cu m
Plant: Palisades Year: 2024 Page 47 of 98 Annual Radiological Environmental Operating Report Page 22 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M BE-7 0.0968 0.03905 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/2024 11:35 4381 CU.M MN-54
<.002382 0.002382 pCi/cu m Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M CO-58
<.003726 0.003726 pCi/cu m Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M FE-59
<.01385 0.01385 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/202411:35 4381 CU.M CO-60
<.001606 0.001606 pCi/cu m Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M ZN-65
<.006453 0.006453 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/202411:35 4381 CU.M NB-95
<.004246 0.004246 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/2024 11:35 4381 CU.M ZR-95
<.007077 0.007077 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/202411:35 4381 CU.M 1-131
<.6321 0.6321 pCi/cu m Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M CS-134
<.002265 0.002265 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/2024 11:35 4381 CU.M CS-137
<.001732 0.001732 pCi/cu m Air Particulate Filters 9TP 4/1/202414:13 7/1/2024 11:35 4381 CU.M BA-140
<.2744 0.2744 pCi/cu m Air Particulate Filters 9TP 4/1/2024 14:13 7/1/2024 11:35 4381 CU.M LA-140
<.1248 0.1248 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M BE-7 0.151 0.03224 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M MN-54
<.001919 0.001919 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M CO-58
<.002701 0.002701 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M FE-59
<.014 0.014 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M CO-60
<.001722 0.001722 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M ZN-65
<.007155 0.007155 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M NB-95
<.004048 0.004048 pCi/cu m Air Particulate Filters 4JS 4/1/202414:22 7/1/202411:45 3910 CU.M ZR-95
<.007069 0.007069 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M 1-131
<.7397 0.7397 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M CS-134
<.001818 0.001818 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M CS-137
<.002103 0.002103 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M BA-140
<.3068 0.3068 pCi/cu m Air Particulate Filters 4JS 4/1/2024 14:22 7/1/202411:45 3910 CU.M LA-140
<.06719 0.06719 pCi/cu m
Plant: Palisades Year: 2024 Page 48 of 98 Annual Radiological Environmental Operating Report Page 23 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M BE-7 0.1069 0.03014 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M MN-54
<.00214 0.00214 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M CO-58
<.003318 0.003318 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M FE-59
<.01148 0.01148 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M CO-60
<.00195 0.00195 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M ZN-65
<.006358 0.006358 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M NB-95
<.004431 0.004431 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M ZR-95
<.006111 0.006111 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M 1-131
<.6204 0.6204 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M CS-134
<.002031 0.002031 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M CS-137
<.002192 0.002192 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M BA-140
<.3196 0.3196 pCi/cu m Air Particulate Filters 5PR 4/1/2024 14:32 7/1/202411:50 3493 CU.M LA-140
<.07819 0.07819 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M BE-7 0.09994 0.03166 pCi/cu m Air Particulate Filters GRl0 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M MN-54
<.001952 0.001952 pCi/cu m Air Particulate Filters GRl0 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M CO-58
<.002986 0.002986 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M FE-59
<.009512 0.009512 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M CO-60
<.001871 0.001871 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M ZN-65
<.005126 0.005126 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M NB-95
<.00331 0.00331 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M ZR-95
<.005506 0.005506 pCi/cu m Air Particulate Filters GRl0 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M 1-131
<.596 0.596 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M CS-134
<.001909 0.001909 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M CS-137
<.00155 0.00155 pCi/cu m Air Particulate Filters GRl0 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M BA-140
<.2318 0.2318 pCi/cu m Air Particulate Filters GRlO 4/1/2024 8:00 7/1/2024 7:30 4706 CU.M LA-140
<.07014 0.07014 pCi/cu m
Plant: Palisades Year: 2024 Page 49 of 98 Annual Radiological Environmental Operating Report Page 24 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M BE-7 0.1068 0.04115 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M MN-54
<.002205 0.002205 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M CO-58
<.003902 0.003902 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M FE-59
<.01358 0.01358 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M CO-60
<.002852 0.002852 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M ZN-65
<.007207 0.007207 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M NB-95
<.005366 0.005366 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M ZR-95
<.008245 0.008245 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M 1-131
<1.194 1.194 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M CS-134
<.002116 0.002116 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M CS-137
<.002521 0.002521 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M BA-140
<.3616 0.3616 pCi/cu m Air Particulate Filters 8SP 7/1/202410:45 9/30/2024 13:45 3958 CU.M LA-140
<.1545 0.1545 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M BE-7 0.1565 0.05623 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M MN-54
<.003625 0.003625 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M CO-58
<.005004 0.005004 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M FE-59
<.0209 0.0209 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M CO-60
<.003801 0.003801 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M ZN-65
<.01035 0.01035 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M NB-95
<.006674 0.006674 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M ZR-95
<.01129 0.01129 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M 1-131
<1.113 1.113 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M CS-134
<.003487 0.003487 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M CS-137
<.002966 0.002966 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M BA-140
<.4998 0.4998 pCi/cu m Air Particulate Filters 19ST 7/1/202411:15 9/30/2024 14:05 4602 CU.M LA-140
<.2257 0.2257 pCi/cu m
Plant: Palisades Year: 2024 Page 50 of 98 Annual Radiological Environmental Operating Report Page 25 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M BE-7 0.1237 0.03172 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M MN-54
<.002065 0.002065 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M CO-58
<.00362 0.00362 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M FE-59
<.01215 0.01215 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M CO-60
<.001952 0.001952 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M ZN-65
<.004963 0.004963 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M NB-95
<.00354 0.00354 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M ZR-95
<.004104 0.004104 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M 1-131
<.7842 0.7842 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M CS-134
<.002541 0.002541 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M CS-137
<.001923 0.001923 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M BA-140
<.2488 0.2488 pCi/cu m Air Particulate Filters 9TP 7/1/202411:35 9/30/2024 14: 15 4454 CU.M LA-140
<.1191 0.1191 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M BE-7 0.1304 0.03752 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M MN-54
<.002635 0.002635 pCi/cu m Air Particulate Filters 4JS 7/1/2024 11:45 9/30/2024 14:25 4015 CU.M CO-58
<.004643 0.004643 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M FE-59
<.01532 0.01532 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M CO-60
<.00281 0.00281 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M ZN-65
<.004092 0.004092 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M NB-95
<.004954 0.004954 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M ZR-95
<.007798 0.007798 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M 1-131
<.9764 0.9764 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M CS-134
<.00296 0.00296 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M CS-137
<.002232 0.002232 pCi/cu m Air Particulate Filters 4JS 7/1/2024 11:45 9/30/2024 14:25 4015 CU.M BA-140
<.3753 0.3753 pCi/cu m Air Particulate Filters 4JS 7/1/202411:45 9/30/2024 14:25 4015 CU.M LA-140
<.113 0.113 pCi/cu m
Plant: Palisades Year: 2024 Page 51 of 98 Annual Radiological Environmental Operating Report Page 26 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M BE-7 0.1136 0.02122 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M MN-54
<.001594 0.001594 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M CO-58
<.00194 0.00194 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M FE-59
<.005182 0.005182 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M CO-60
<.001996 0.001996 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M ZN-65
<.003905 0.003905 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M NB-95
<.003067 0.003067 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M ZR-95
<.003456 0.003456 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M 1-131
<.6297 0.6297 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M CS-134
<.001903 0.001903 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M CS-137
<.00137 0.00137 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M BA-140
<.1983 0.1983 pCi/cu m Air Particulate Filters 5PR 7/1/202411:50 9/30/2024 14:35 3746 CU.M LA-140
<.09599 0.09599 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M BE-7 0.1005 0.02008 pCi/cu m Air Particulate Filters GRl0 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M MN-54
<.001428 0.001428 pCi/cu m Air Particulate Filters GRl0 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M CO-58
<.002215 0.002215 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M FE-59
<.008992 0.008992 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M CO-60
<.002348 0.002348 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M ZN-65
<.002659 0.002659 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M NB-95
<.001609 0.001609 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M ZR-95
<.004723 0.004723 pCi/cu m Air Particulate Filters GRl0 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M 1-131
<.5835 0.5835 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M CS-134
<.001501 0.001501 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M CS-137
<.001443 0.001443 pCi/cu m Air Particulate Filters GRl0 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M BA-140
<.2071 0.2071 pCi/cu m Air Particulate Filters GRlO 7/1/2024 7:30 9/30/2024 8:00 4601 CU.M LA-140
<.09413 0.09413 pCi/cu m
Plant: Palisades Year: 2024 Page 52 of 98 Annual Radiological Environmental Operating Report Page 27 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M BE-7 0.08539 0.02772 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M MN-54
<.001882 0.001882 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M CO-58
<.003373 0.003373 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M FE-59
<.00967 0.00967 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M CO-60
<.002403 0.002403 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M ZN-65
<.003901 0.003901 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M NB-95
<.00308 0.00308 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M ZR-95
<.006813 0.006813 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M 1-131
<.3009 0.3009 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M CS-134
<.002068 0.002068 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M CS-137
<.002169 0.002169 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M BA-140
<.1649 0.1649 pCi/cu m Air Particulate Filters 8SP 9/30/2024 13:45 12/30/2024 12:33 4511 CU.M LA-140
<.06108 0.06108 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M BE-7 0.06643 0.02331 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M MN-54
<.002053 0.002053 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M CO-58
<.002506 0.002506 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M FE-59
<.00726 0.00726 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M CO-60
<.001956 0.001956 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M ZN-65
<.00458 0.00458 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M NB-95
<.003461 0.003461 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M ZR-95
<.006134 0.006134 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M 1-131
<.2803 0.2803 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M CS-134
<.002032 0.002032 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M CS-137
<.001814 0.001814 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M BA-140
<.1176 0.1176 pCi/cu m Air Particulate Filters 19ST 9/30/2024 14:05 12/30/2024 12:45 4709 CU.M LA-140
<.0575 0.0575 pCi/cu m
Plant: Palisades Year: 2024 Page 53 of 98 Annual Radiological Environmental Operating Report Page 28 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M BE-7 0.08059 0.03908 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M MN-54
<.002824 0.002824 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M CO-58
<.003499 0.003499 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M FE-59
<.01351 0.01351 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M CO-60
<.002239 0.002239 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M ZN-65
<.007607 0.007607 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M NB-95
<.003884 0.003884 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M ZR-95
<.00822 0.00822 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M 1-131
<.3628 0.3628 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M CS-134
<.002736 0.002736 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M CS-137
<.00235 0.00235 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M BA-140
<.1735 0.1735 pCi/cu m Air Particulate Filters 9TP 9/30/202414:15 12/30/202412:58 4766 CU.M LA-140
<.08559 0.08559 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M BE-7 0.106 0.02361 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M MN-54
<.001297 0.001297 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M CO-58
<.002343 0.002343 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M FE-59
<.01058 0.01058 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M CO-60
<.002072 0.002072 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M ZN-65
<.004838 0.004838 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M NB-95
<.002986 0.002986 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M ZR-95
<.005909 0.005909 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M 1-131
<.3051 0.3051 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M CS-134
<.002212 0.002212 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M CS-137
<.0017 0.0017 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M BA-140
<.1206 0.1206 pCi/cu m Air Particulate Filters 4JS 9/30/2024 14:25 12/30/2024 13:08 4174 CU.M LA-140
<.05961 0.05961 pCi/cu m
Plant: Palisades Year: 2024 Page 54 of 98 Annual Radiological Environmental Operating Report Page 29 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M BE-7 0.07515 0.03717 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M MN-54
<.002213 0.002213 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M CO-58
<.003756 0.003756 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M FE-59
<.01104 0.01104 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M CO-60
<.002471 0.002471 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M ZN-65
<.006395 0.006395 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M NB-95
<.004727 0.004727 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M ZR-95
<.007966 0.007966 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M 1-131
<.3801 0.3801 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M CS-134
<.002692 0.002692 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M CS-137
<.00195 0.00195 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M BA-140
<.1685 0.1685 pCi/cu m Air Particulate Filters 5PR 9/30/202414:35 12/30/202413:16 4225 CU.M LA-140
<.07726 0.07726 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M BE-7 0.1079 0.05259 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M MN-54
<.006246 0.006246 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M CO-58
<.007664 0.007664 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M FE-59
<.02117 0.02117 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M CO-60
<.006775 0.006775 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M ZN-65
<.01511 0.01511 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M NB-95
<.005994 0.005994 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M ZR-95
<.01068 0.01068 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M 1-131
<.03073 0.03073 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M CS-134
<.005353 0.005353 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M CS-137
<.005788 0.005788 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M BA-140
<.06728 0.06728 pCi/cu m Air Particulate Filters 12 12/9/2024 14:30 12/30/2024 8:07 1138 CU.M LA-140
<.03541 0.03541 pCi/cu m
Plant: Palisades Year: 2024 Page 55 of 98 Annual Radiological Environmental Operating Report Page 30 of 68 REMP Sample Results Matrix Station Start Date Stop Date Volume Volume Units Analysis Reportable Result MDC Units Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M BE-7 0.07673 0.05027 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M MN-54
<.002893 0.002893 pCi/cu m Air Particulate Filters GR10 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M CO-58
<.005287 0.005287 pCi/cu m Air Particulate Filters GR10 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M FE-59
<.02079 0.02079 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M CO-60
<.002628 0.002628 pCi/cu m Air Particulate Filters GR10 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M ZN-65
<.007876 0.007876 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M NB-95
<.006214 0.006214 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M ZR-95
<.01005 0.01005 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M 1-131
<1.99 1.99 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M CS-134
<.003091 0.003091 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M CS-137
<.002691 0.002691 pCi/cu m Air Particulate Filters GRlO 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M BA-140
<.5443 0.5443 pCi/cu m Air Particulate Filters GR10 9/30/2024 8:00 11/25/2024 7:00 2285 CU.M LA-140
<.2409 0.2409 pCi/cu m
Plant: Palisades Year: 2024 Page 56 of 98 Annual Radiological Environmental Operating Report Page 31 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 GR-B 2.82 2.82 2.19 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 H-3 (DIST)
<653 244 653 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 MN-54
<1.548
-0.5215 1.548 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 CO-58
<1.895
-0.2168 1.895 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 FE-59
<4.571 0.7383 4.571 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 CO-60
<1.713 0.2321 1.713 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 ZN-65
<3.662
-2.662 3.662 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 NB-95
<2.1 0.6937 2.1 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 ZR-95
<3.476 0.2892 3.476 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 1-131
<19.14 2.101 19.14 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 CS-134
<1.779 0.3149 1.779 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 CS-137
<1.714 0.3958 1.714 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 BA-140
<25.44
-1.449 25.44 pCi/L Drinking Water DOMESTIC WATER 1/1/2024 0:00 2/1/2024 0:00 LA-140
<8.692
-0.5551 8.692 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 GR-B
<1.93 1.59 1.93 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 H-3 (DIST)
<649
-108 649 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 MN-54
<1.969
-0.3553 1.969 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 CO-58
<2.316
-0.4135 2.316 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 FE-59
<5.57 2.24 5.57 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 CO-60
<2.225 0.5244 2.225 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 ZN-65
<4.397
-8.549 4.397 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 NB-95
<2.527 0.9913 2.527 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 ZR-95
<4.264 0.9117 4.264 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 1-131
<15.8
-5.351 15.8 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 CS-134
<2.255 0.03932 2.255 pCi/L
Plant: Palisades Year: 2024 Page 57 of 98 Annual Radiological Environmental Operating Report Page 32 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 BA-140
<25.67 4.156 25.67 pCi/L Drinking Water DOMESTIC WATER 2/1/2024 0:00 3/1/2024 0:00 LA-140
<9.406 0.8105 9.406 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 GR-B
<2.51 1.44 2.51 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 H-3 (DIST)
<628 2.11 628 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 MN-54
<3.261
-0.04348 3.261 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 CO-58
<3.925 0.1486 3.925 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 FE-59
<9.263 0.8254 9.263 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 CO-60
<3.627 0.6474 3.627 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 ZN-65
<7.493
-5.89 7.493 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 NB-95
<4.16 1.385 4.16 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 ZR-95
<8.416 5.408 8.416 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 1-131
<26.82
-6.658 26.82 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 CS-134
<3.126
-1.019 3.126 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 CS-137
<3.66 0.4078 3.66 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 BA-140
<39.75
-11.33 39.75 pCi/L Drinking Water DOMESTIC WATER 3/1/2024 0:00 4/1/2024 0:00 LA-140
<13.71
-5.783 13.71 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 GR-B
<2.12 1.38 2.12 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 H-3 (DIST)
<734 8.78 734 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 MN-54
<1.893 0.1521 1.893 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 CO-58
<2.519 0.6316 2.519 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 FE-59
<6.025 4.022 6.025 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 CO-60
<1.963 0.2717 1.963 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 ZN-65
<4.054
-1.785 4.054 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 NB-95
<2.383
-0.2359 2.383 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 ZR-95
<4.433 0.6297 4.433 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 1-131
<19.18
-0.8093 19.18 pCi/L
Plant: Palisades Year: 2024 Page 58 of 98 Annual Radiological Environmental Operating Report Page 33 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 CS-134
<2.214 1.047 2.214 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 CS-137
<1.932
-0.7849 1.932 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 BA-140
<28.95 20.39 28.95 pCi/L Drinking Water DOMESTIC WATER 4/1/2024 0:00 5/1/2024 0:00 LA-140
<9.376
-0.873 9.376 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 GR-B 2.64 2.64 2.23 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 H-3 (DIST)
<625 98.2 625 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 K-40 30.63 30.63 15.73 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 MN-54
<1.415
-0.3518 1.415 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 CO-58
<1.618
-0.2088 1.618 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 FE-59
<4.274 0.9745 4.274 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 CO-60
<1.749 1.224 1.749 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 ZN-65
<3.375 0.5569 3.375 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 NB-95
<1.713
-0.6026 1.713 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 ZR-95
<3.047 0.2059 3.047 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 1-131
<13.71 4.135 13.71 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 CS-134
<1.664
-0.1706 1.664 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 CS-137
<1.308
-0.2876 1.308 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 BA-140
<19.35
-1.519 19.35 pCi/L Drinking Water DOMESTIC WATER 5/1/2024 0:00 6/1/2024 0:00 LA-140
<6.894 2.091 6.894 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 GR-B
<2.37 1.62 2.37 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 H-3 (DIST)
<711
-127 711 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 MN-54
<1.78 0.07991 1.78 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 CO-58
<2.012 0.2068 2.012 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 FE-59
<4.634 4.065 4.634 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 CO-60
<1.996 0.3004 1.996 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 ZN-65
<3.695
-0.5967 3.695 pCi/L
Plant: Palisades Year: 2024 Page 59 of 98 Annual Radiological Environmental Operating Report Page 34 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 NB-95
<1.812
-1.294 1.812 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 ZR-95
<3.566 0.4711 3.566 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 1-131
<7.763 0.9054 7.763 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 CS-134
<2.025
-0.004758 2.025 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 CS-137
<1.87 0.9207 1.87 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 BA-140
<15.17
-2.189 15.17 pCi/L Drinking Water DOMESTIC WATER 6/1/2024 0:00 7/1/2024 0:00 LA-140
<5.004
-0.5062 5.004 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 GR-B
<2.57 0.8 2.57 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 H-3 (DIST)
<584
-34.9 584 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 MN-54
<2.004 0.1707 2.004 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 CO-58
<2.363
-0.2187 2.363 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 FE-59
<5.032
-0.1374 5.032 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 CO-60
<1.803
-0.6026 1.803 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 ZN-65
<3.876
-4.137 3.876 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 NB-95
<2.317
-0.2711 2.317 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 ZR-95
<4.223 1.327 4.223 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 1-131
<11.33 3.672 11.33 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 CS-134
<2.114 0.1756 2.114 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 CS-137
<2.036 0.2232 2.036 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 BA-140
<20.28 5.319 20.28 pCi/L Drinking Water DOMESTIC WATER 7/1/2024 0:00 8/1/2024 0:00 LA-140
<7.062
-0.9213 7.062 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 GR-B 3.4 3.4 2.43 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 H-3 (DIST)
<338 4.3 338 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 MN-54
<2.064
-0.8558 2.064 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 CO-58
<2.372
-0.1708 2.372 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 FE-59
<5.205
-0.3194 5.205 pCi/L
Plant: Palisades Year: 2024 Page 60 of 98 Annual Radiological Environmental Operating Report Page 35 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 CO-60
<2.681 1.944 2.681 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 ZN-65
<4.318
-5.399 4.318 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 NB-95
<2.732 1.491 2.732 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 ZR-95
<4.146
-1.12 4.146 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 1-131
<14.55 0.638 14.55 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 CS-134
<2.276
-0.295 2.276 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 CS-137
<2.178 0.6884 2.178 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 BA-140
<24.17 0.3991 24.17 pCi/L Drinking Water DOMESTIC WATER 8/1/2024 0:00 9/3/2024 0:00 LA-140
<7.177
-1.874 7.177 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 GR-B 2.84 2.84 2.38 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 H-3 (DIST)
<611
-13.1 611 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 K-40 24.31 24.31 13.27 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 MN-54
<1.288
-0.2691 1.288 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 CO-58
<1.545 0.3878 1.545 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 FE-59
<3.491 1.296 3.491 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 CO-60
<1.401
-0.1175 1.401 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 ZN-65
<3.002
-0.2175 3.002 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 NB-95
<1.615 0.211 1.615 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 ZR-95
<2.758
-0.5315 2.758 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 1-131
<7.954
-0.07058 7.954 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 CS-134
<1.43 0.1036 1.43 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 CS-137
<1.383 0.3355 1.383 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 BA-140
<12.77
-8.714 12.77 pCi/L Drinking Water DOMESTIC WATER 9/3/2024 0:00 10/1/2024 0:00 LA-140
<4.974
-0.3293 4.974 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 GR-B
<2.59 2.38 2.59 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 H-3 (DIST)
<575
-8.08 575 pCi/L
Plant: Palisades Year: 2024 Page 61 of 98 Annual Radiological Environmental Operating Report Page 36 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 MN-54
<2.19 1.136 2.19 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 CO-58
<2.518 0.1031 2.518 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 FE-59
<6.078 5.354 6.078 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 CO-60
<2.352 1.284 2.352 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 ZN-65
<4.475
-2.315 4.475 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 NB-95
<2.599 1.386 2.599 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 ZR-95
<4.353 0.05639 4.353 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 1-131
<18.82 1.322 18.82 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 CS-134
<2.363 0.9148 2.363 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 CS-137
<2.063
-0.2565 2.063 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 BA-140
<27.32
-12.49 27.32 pCi/L Drinking Water DOMESTIC WATER 10/1/2024 0:00 11/1/2024 0:00 LA-140
<9.566 0.1041 9.566 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 GR-B
<2.58 2.55 2.58 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 H-3 (DIST)
<538 89 538 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 MN-54
<1.79 0.3414 1.79 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 CO-58
<2.204
-0.4474 2.204 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 FE-59
<5.167 0.1661 5.167 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 CO-60
<1.952 0.9138 1.952 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 ZN-65
<4.038
-3.053 4.038 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 NB-95
<2.482 0.6099 2.482 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 ZR-95
<4.061 0.09118 4.061 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 1-131
<16.35
-0.8074 16.35 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 CS-134
<1.983
-0.7832 1.983 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 CS-137
<1.985 1.03 1.985 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 BA-140
<25.74
-0.1938 25.74 pCi/L Drinking Water DOMESTIC WATER 11/1/2024 0:00 12/1/2024 0:00 LA-140
<8.101
-1.601 8.101 pCi/L
Plant: Palisades Year: 2024 Page 62 of 98 Annual Radiological Environmental Operating Report Page 37 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 GR-B
<3.85 3.11 3.85 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 H-3 (DIST)
<577
-27 577 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 K-40 40.42 40.42 17.82 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 MN-54
<2.075 0.6363 2.075 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 CO-58
<2.268 0.1699 2.268 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 FE-59
<5.108
-0.1622 5.108 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 CO-60
<2.176 0.1901 2.176 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 ZN-65
<4.167
-2.498 4.167 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 NB-95
<2.312 0.2367 2.312 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 ZR-95
<4.16 0.3818 4.16 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 1-131
<13.95 6.16 13.95 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 CS-134
<2.258
-0.1023 2.258 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 CS-137
<2.018 0.3116 2.018 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 BA-140
<21.48
-15.33 21.48 pCi/L Drinking Water DOMESTIC WATER 12/1/2024 0:00 1/1/2025 0:00 LA-140
<7.608
-2.29 7.608 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 GR-B
<2.15 1.9 2.15 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 H-3 (DIST)
<647
-142 647 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 MN-54
<1.545
-0.8845 1.545 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 CO-58
<1.905 0.03931 1.905 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 FE-59
<4.64 1.328 4.64 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 CO-60
<1.789
-0.01439 1.789 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 ZN-65
<3.471
-2.228 3.471 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 NB-95
<1.966
-0.2084 1.966 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 ZR-95
<3.485
-1.539 3.485 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 1-131
<19.34 2.364 19.34 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 CS-134
<1.907 1.668 1.907 pCi/L
Plant: Palisades Year: 2024 Page 63 of 98 Annual Radiological Environmental Operating Report Page 38 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 CS-137
<1.635
-0.05595 1.635 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 BA-140
<25.9 14.33 25.9 pCi/L Drinking Water SOUTH HAVEN RAW 1/1/2024 0:00 2/1/2024 0:00 LA-140
<9.15 4.584 9.15 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 GR-B 3.07 3.07 1.93 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 H-3 (DIST)
<646 15 646 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 K-40 33.02 33.02 17.97 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 MN-54
<2.159 1.019 2.159 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 CO-58
<2.481
-1.388 2.481 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 FE-59
<5.771 2.363 5.771 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 CO-60
<2.367 2.361 2.367 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 ZN-65
<4.606
-1.655 4.606 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 NB-95
<2.688 2.614 2.688 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 ZR-95
<4.385
-0.7526 4.385 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 1-131
<19.71 1.142 19.71 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 CS-134
<2.256
-1.585 2.256 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 CS-137
<2.118
-0.591 2.118 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 BA-140
<28.97
-6.409 28.97 pCi/L Drinking Water SOUTH HAVEN RAW 2/1/2024 0:00 3/1/2024 0:00 LA-140
<9.096 1.067 9.096 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 GR-B
<2.54 1.46 2.54 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 H-3 (DIST)
<638 83.7 638 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 MN-54
<2.745 0.3413 2.745 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 CO-58
<2.927
-0.8545 2.927 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 FE-59
<7.667
-1.089 7.667 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 CO-60
<3.08 0.736 3.08 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 ZN-65
<5.7 0.01685 5.7 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 NB-95
<3.448
-0.1881 3.448 pCi/L
Plant: Palisades Year: 2024 Page 64 of 98 Annual Radiological Environmental Operating Report Page 39 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 ZR-95
<5.746
-0.3025 5.746 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 1-131
<22.07
-0.499 22.07 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 CS-134
<3.156
-0.04356 3.156 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 CS-137
<2.522
-1.419 2.522 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 BA-140
<39.34 4.439 39.34 pCi/L Drinking Water SOUTH HAVEN RAW 3/1/2024 0:00 4/1/2024 0:00 LA-140
<11.73
-5.256 11.73 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 GR-B
<2.58 2.2 2.58 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 H-3 (DIST)
<740
-186 740 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 MN-54
<2.591 1.454 2.591 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 CO-58
<2.933
-1.817 2.933 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 FE-59
<7.676 4.226 7.676 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 CO-60
<2.708 0.1238 2.708 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 ZN-65
<5.939
-1.637 5.939 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 NB-95
<3.252 0.602 3.252 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 ZR-95
<5.358
-0.6167 5.358 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 1-131
<26.47 3.809 26.47 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 CS-134
<2.705 1.209 2.705 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 CS-137
<2.393
-0.3844 2.393 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 BA-140
<37.01
-0.1767 37.01 pCi/L Drinking Water SOUTH HAVEN RAW 4/1/2024 0:00 5/1/2024 0:00 LA-140
<13.16
-0.2495 13.16 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 GR-B 2.64 2.64 2.18 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 H-3 (DIST)
<628
-2.19 628 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 MN-54
<2.393 0.5998 2.393 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 CO-58
<2.821 0.5658 2.821 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 FE-59
<6.555 3.887 6.555 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 CO-60
<2.63 1.495 2.63 pCi/L
Plant: Palisades Year: 2024 Page 65 of 98 Annual Radiological Environmental Operating Report Page 40 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 ZN-65
<4.954
-4.252 4.954 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 NB-95
<2.855 1.365 2.855 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 ZR-95
<5.162 3.316 5.162 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 1-131
<18.87
-3.545 18.87 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 CS-134
<2.499
-0.7382 2.499 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 CS-137
<2.426 0.5734 2.426 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 BA-140
<30.14 0.5493 30.14 pCi/L Drinking Water SOUTH HAVEN RAW 5/1/2024 0:00 6/1/2024 0:00 LA-140
<10.77 7.814 10.77 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 GR-B 2.59 2.59 2.34 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 H-3 (DIST)
<676 610 676 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 MN-54
<2.178 0.7191 2.178 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 CO-58
<2.293
-1.199 2.293 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 FE-59
<5.228 2.96 5.228 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 CO-60
<2.264 0.04937 2.264 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 ZN-65
<4.529
-2.03 4.529 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 NB-95
<2.421
-0.05814 2.421 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 ZR-95
<4.268 0.7655 4.268 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 1-131
<9.3
-0.7367 9.3 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 CS-134
<2.353 0.2496 2.353 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 CS-137
<2.336 1.147 2.336 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 BA-140
<17.98
-1.6 17.98 pCi/L Drinking Water SOUTH HAVEN RAW 6/1/2024 0:00 7/1/2024 0:00 LA-140
<6.246
-4.011 6.246 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 GR-B
<2.35 1.47 2.35 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 H-3 (DIST)
<582 69.7 582 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 K-40 22.87 22.87 15.86 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 MN-54
<1.562 0.257 1.562 pCi/L
Plant: Palisades Year: 2024 Page 66 of 98 Annual Radiological Environmental Operating Report Page 41 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 CO-58
<1.704
-1.046 1.704 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 FE-59
<4.329 1.282 4.329 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 CO-60
<1.756 0.453 1.756 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 ZN-65
<3.327
-1.231 3.327 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 NB-95
<1.829 0.7445 1.829 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 ZR-95
<3.013
-1.163 3.013 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 1-131
<16.02
-1.26 16.02 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 CS-134
<1.606 0.6488 1.606 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 CS-137
<1.448
-0.1098 1.448 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 BA-140
<22.15 3.05 22.15 pCi/L Drinking Water SOUTH HAVEN RAW 7/1/2024 0:00 8/1/2024 0:00 LA-140
<8.22 0.8015 8.22 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 GR-B 3.11 3.11 2.31 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 H-3 (DIST)
<321
-69.3 321 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 MN-54
<2.09
-0.01651 2.09 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 CO-58
<2.472 0.3594 2.472 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 FE-59
<5.642 1.872 5.642 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 CO-60
<2.496
-0.09465 2.496 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 ZN-65
<4.412
-2.515 4.412 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 NB-95
<2.524 0.1491 2.524 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 ZR-95
<4.549 0.948 4.549 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 1-131
<16.28 1.568 16.28 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 CS-134
<2.204 0.5196 2.204 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 CS-137
<2.076 0.1389 2.076 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 BA-140
<25.79 0.1893 25.79 pCi/L Drinking Water SOUTH HAVEN RAW 8/1/2024 0:00 9/1/2024 0:00 LA-140
<8.424
-4.67 8.424 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 GR-B 2.78 2.78 2.07 pCi/L
Plant: Palisades Year: 2024 Page 67 of 98 Annual Radiological Environmental Operating Report Page 42 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 H-3 (DIST)
<602
-25.8 602 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 MN-54
<1.982
-0.2337 1.982 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 CO-58
<2.197 0.1406 2.197 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 FE-59
<5.266 1.573 5.266 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 CO-60
<2.047 0.1659 2.047 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 ZN-65
<4.006
-4.233 4.006 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 NB-95
<2.39 0.476 2.39 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 ZR-95
<4.059 0.4075 4.059 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 1-131
<14.44
-2.514 14.44 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 CS-134
<2.149 1.116 2.149 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 CS-137
<1.937
-0.6901 1.937 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 BA-140
<24.03 5.059 24.03 pCi/L Drinking Water SOUTH HAVEN RAW 9/1/2024 0:00 10/1/2024 0:00 LA-140
<8.014 1.326 8.014 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 GR-B 3.08 3.08 2.67 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 H-3 (DIST)
<584 140 584 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 K-40 23.65 23.65 14.59 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 MN-54
<1.409
-0.606 1.409 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 CO-58
<1.598
-0.2124 1.598 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 FE-59
<4.13 1.493 4.13 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 CO-60
<1.623 0.2945 1.623 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 ZN-65
<3.31 0.2435 3.31 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 NB-95
<1.789 0.1188 1.789 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 ZR-95
<2.772
-0.7422 2.772 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 1-131
<13.35 1.815 13.35 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 CS-134
<1.464 0.06711 1.464 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 CS-137
<1.374
-0.4118 1.374 pCi/L
Plant: Palisades Year: 2024 Page 68 of 98 Annual Radiological Environmental Operating Report Page 43 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 BA-140
<17.7
-4.927 17.7 pCi/L Drinking Water SOUTH HAVEN RAW 10/1/2024 0:00 11/1/2024 0:00 LA-140
<7.359 0.9016 7.359 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 GR-B 2.46 2.46 2.42 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 H-3 (DIST)
<543 131 543 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 MN-54
<1.452
-0.05069 1.452 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 CO-58
<1.595
-0.5942 1.595 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 FE-59
<3.902 0.2395 3.902 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 CO-60
<1.556
-0.04739 1.556 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 ZN-65
<3.114
-0.4177 3.114 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 NB-95
<1.813 1.195 1.813 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 ZR-95
<3.146 0.7211 3.146 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 1-131
<12.77 3.273 12.77 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 CS-134
<1.539 0.1695 1.539 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 CS-137
<1.462 0.4644 1.462 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 BA-140
<17.79 0.2027 17.79 pCi/L Drinking Water SOUTH HAVEN RAW 11/1/2024 0:00 12/1/2024 0:00 LA-140
<7.001 0.7724 7.001 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 GR-B 2.83 2.83 2.13 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 H-3 (DIST)
<563 50.5 563 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 MN-54
<1.281 0.1469 1.281 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 CO-58
<1.497
-0.3906 1.497 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 FE-59
<3.639 0.3668 3.639 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 CO-60
<1.491 0.9167 1.491 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 ZN-65
<2.506
-2.257 2.506 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 NB-95
<1.581
-0.1195 1.581 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 ZR-95
<2.642 0.04038 2.642 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 1-131
<13.52
-1.096 13.52 pCi/L
Plant: Palisades I
Year: 2024 I Page 69 of 98 Annual Radiological Environmental Operating Report Page 44 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 CS-134
<1.42 0.6937 1.42 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 CS-137
<1.237 0.2587 1.237 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 BA-140
<17.49
-12.27 17.49 pCi/L Drinking Water SOUTH HAVEN RAW 12/1/2024 0:00 1/1/2025 0:00 LA-140
<6.817 0.4676 6.817 pCi/L Matrix Station Start Date Analysis Reportable Result Activity MDC Units Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 GR-B 4.6 4.6 3.56 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 H-3 (DIST)
<509
-25.5 509 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 MN-54
<5.75 0.3243 5.75 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 CO-58
<6.38 0.4371 6.38 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 FE-59
<10.87 0.04181 10.87 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 CO-60
<7.067 1.84 7.067 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 ZN-65
<9.786
-3.202 9.786 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 NB-95
<6.281
-0.02689 6.281 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 ZR-95
<11.14 3.134 11.14 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 1-131
<7.536
-1.98 7.536 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 CS-134
<6.845
-1.221 6.845 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 CS-137
<4.852
-2.05 4.852 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 BA-140
<22.63 2.366 22.63 pCi/L Drinking Water PALISADES PARK COMMERCIAL 5/20/2024 13:34 LA-140
<5.99
-2.142 5.99 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 GR-B
<2.32 2.03 2.32 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 H-3 (DIST)
<681 32.1 681 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 MN-54
<6.8
-0.364 6.8 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 CO-58
<9.774 3.746 9.774 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 FE-59
<17.8
-1.772 17.8 pCi/L
Plant: Palisades Year: 2024 Page 70 of 98 Annual Radiological Environmental Operating Report Page 45 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 ZN-65
<12.44
-2.648 12.44 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 NB-95
<8.457 3.007 8.457 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 ZR-95
<13.31 3.295 13.31 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 1-131
<11.74
-0.2536 11.74 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 CS-134
<8.807 1.005 8.807 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/2024 11:00 CS-137
<6.315
-3.82 6.315 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 BA-140
<41.46 5.893 41.46 pCi/L Drinking Water PALISADES PARK COMMERCIAL 6/10/202411:00 LA-140
<13.22
-0.7779 13.22 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 GR-B
<2.31 0.639 2.31 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 H-3 (DIST)
<605
-224 605 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 MN-54
<5.458
-1.443 5.458 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 CO-58
<5.228 0.117 5.228 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 FE-59
<11.24 3.012 11.24 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 CO-60
<6.357
-0.2359 6.357 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 ZN-65
<10.88
-8.932 10.88 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 NB-95
<5.487 0.2238 5.487 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 ZR-95
<9.393
-0.4958 9.393 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 1-131
<6.977 1.167 6.977 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 CS-134
<6.61 0.2137 6.61 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 CS-137
<5.551
-1.157 5.551 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 BA-140
<19.6
-5.331 19.6 pCi/L Drinking Water PALISADES PARK COMMERCIAL 7/15/202412:20 LA-140
<8.597 1.64 8.597 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 GR-B
<3.37 3.12 3.37 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 H-3 (DIST)
<583 150 583 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/2024 14:10 MN-54
<5.564 0.6634 5.564 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 CO-58
<4.848
-1.233 4.848 pCi/L
Plant: Palisades Year: 2024 Page 71 of 98 Annual Radiological Environmental Operating Report Page 46 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 FE-59
<11.22
-1.311 11.22 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 CO-60
<6.717 2.373 6.717 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 ZN-65
<11.99
-2.603 11.99 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/2024 14:10 NB-95
<5.939 1.132 5.939 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 ZR-95
<10.42 3.42 10.42 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/2024 14:10 1-131
<9.461
-2.627 9.461 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 CS-134
<5.103
-0.7609 5.103 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 CS-137
<4.764 0.4177 4.764 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 BA-140
<27.29 8.351 27.29 pCi/L Drinking Water PALISADES PARK COMMERCIAL 8/5/202414:10 LA-140
<9.984 1.586 9.984 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 GR-B
<2.18
-0.273 2.18 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 H-3 (DIST)
<321
-81.5 321 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 MN-54
<6.664 1.651 6.664 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 CO-58
<5.147
-2.031 5.147 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 FE-59
<14.61 5.573 14.61 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 CO-60
<8.093 0.6978 8.093 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 ZN-65
<12.69
-12.42 12.69 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 NB-95
<7.073 1.109 7.073 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 ZR-95
<9.904
-6.568 9.904 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 1-131
<8.845 0.05321 8.845 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 CS-134
<8.191 2.039 8.191 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 CS-137
<5.278
-2.794 5.278 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 BA-140
<29.13 4.205 29.13 pCi/L Drinking Water PALISADES PARK COMMERCIAL 9/9/2024 14:00 LA-140
<10.64 1.347 10.64 pCi/L
Plant: Palisades Year: 2024 Page 72 of 98 Annual Radiological Environmental Operating Report Page 47 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Fish LUDINGTON DRUM 5/27/202412:00 K-40 2676 2676 378.9 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 MN-54
<38.05
-4.002 38.05 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 CO-58
<38.69
-13.71 38.69 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 FE-59
<88.06 9.321 88.06 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 CO-60
<41.92 17.86 41.92 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 ZN-65
<79.64
-48.39 79.64 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 NB-95
<43.44 26.53 43.44 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 ZR-95
<75.18 21.85 75.18 pCi/kgWet Fish LUDINGTON DRUM 5/27/2024 12:00 1-131
<244.9
-111.2 244.9 pCi/kgWet Fish LUDINGTON DRUM 5/27/2024 12:00 CS-134
<40.79 3.95 40.79 pCi/kgWet Fish LUDINGTON DRUM 5/27/2024 12:00 CS-137
<42.28 20.52 42.28 pCi/kgWet Fish LUDINGTON DRUM 5/27/2024 12:00 BA-140
<429.1 293.2 429.1 pCi/kgWet Fish LUDINGTON DRUM 5/27/202412:00 LA-140
<134.3
-1.467 134.3 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 K-40 1757 1757 757.5 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 MN-54
<73.37 31.89 73.37 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 CO-58
<57.41 2.447 57.41 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 FE-59
<149.5
-8.284 149.5 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 CO-60
<39.25
-30.12 39.25 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 ZN-65
<128.1
-18.03 128.1 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 NB-95
<63.79 4.283 63.79 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 ZR-95
<89.26
-6.354 89.26 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 1-131
<181.3 68.81 181.3 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 CS-134
<59.9 0.9165 59.9 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 CS-137
<46.48
-12.32 46.48 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 BA-140
<377.7
-30.67 377.7 pCi/kgWet Fish LUNDINGTON SALMON 9/12/2024 0:00 LA-140
<105.3
-0.476 105.3 pCi/kgWet
Plant: Palisades Year: 2024 Page 73 of 98 Annual Radiological Environmental Operating Report Page 48 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Fish LUNDINGTON DRUM 9/12/2024 0:00 K-40 2495 2495 525.9 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 MN-54
<59.4
-17.42 59.4 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 CO-58
<83.28 14.73 83.28 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 FE-59
<187.4 11.93 187.4 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 CO-60
<91.05 41.76 91.05 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 ZN-65
<157.2
-117.7 157.2 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 NB-95
<82.14
-35.69 82.14 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 ZR-95
<129
-60.33 129 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 1-131
<201.9
-13.98 201.9 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 CS-134
<70.52
-7.035 70.52 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 CS-137
<91.38 20.83 91.38 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 BA-140
<513.4 323.9 513.4 pCi/kgWet Fish LUNDINGTON DRUM 9/12/2024 0:00 LA-140
<86.82
-103.1 86.82 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 K-40 4239 4239 775.2 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 MN-54
<55.06
-27.15 55.06 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 CO-58
<53.55
-53.08 53.55 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 FE-59
<169.9 21.11 169.9 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 CO-60
<73.32
-1.509 73.32 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 ZN-65
<173.5
-40.12 173.5 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 NB-95
<84.73 29.47 84.73 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 ZR-95
<113.7
-13.18 113.7 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 1-131
<357.3 89.21 357.3 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 CS-134
<73.58
-4.316 73.58 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 CS-137
<75.32 11.28 75.32 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 BA-140
<577.5
-94.72 577.5 pCi/kgWet Fish PALISADES SALMON 9/5/2024 11:30 LA-140
<167.4
-59.3 167.4 pCi/kgWet
Plant: Palisades Year: 2024 Page 74 of 98 Annual Radiological Environmental Operating Report Page 49 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 K-40 2609 2609 484.7 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 MN-54
<72.86 23.13 72.86 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 CO-58
<59.44
-25.86 59.44 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 FE-59
<166.3
-22.9 166.3 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 CO-60
<79.15 30.19 79.15 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 ZN-65
<130.5
-34.63 130.5 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 NB-95
<51.88
-22.14 51.88 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 ZR-95
<105.1
-0.7367 105.1 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 1-131
<267.4 59.25 267.4 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 CS-134
<54.76
-14.04 54.76 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 CS-137
<69.4 24 69.4 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 BA-140
<593.9 126.9 593.9 pCi/kgWet Fish PALISADES GIZZARD SHAD 9/5/2024 11:30 LA-140
<206.8
-16.65 206.8 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 K-40 2868 2868 504.1 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 MN-54
<57.52 16.14 57.52 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 CO-58
<56.19
-6.094 56.19 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 FE-59
<143.3 18.68 143.3 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 CO-60
<47.52
-0.5659 47.52 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 ZN-65
<126.6
-41.97 126.6 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 NB-95
<77.04 36.33 77.04 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 ZR-95
<88.84
-31.23 88.84 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 1-131
<313 38.36 313 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 CS-134
<57.27
-3.051 57.27 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 CS-137
<62.35
-0.8808 62.35 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 BA-140
<561.5
-83.52 561.5 pCi/kgWet Fish PALISADES DRUM 9/4/2024 9:19 LA-140
<244.7 60.76 244.7 pCi/kgWet
Plant: Palisades Year: 2024 Page 75 of 98 Annual Radiological Environmental Operating Report Page 50 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Fish PALISADES BASS 5/24/2024 8:00 K-40 3834 3834 520.3 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 MN-54
<57.4 9.506 57.4 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 CO-58
<50.18
-11.56 50.18 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 FE-59
<117.4
-11 117.4 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 CO-60
<60.8
-6.505 60.8 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 ZN-65
<139.4
-51.28 139.4 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 NB-95
<50.9
-8.804 50.9 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 ZR-95
<93.2 12.46 93.2 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 1-131
<66.74
-30.28 66.74 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 CS-134
<63.92
-3.173 63.92 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 CS-137
<48.35
-15.71 48.35 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 BA-140
<243.1 13.43 243.1 pCi/kgWet Fish PALISADES BASS 5/24/2024 8:00 LA-140
<100.2 15.96 100.2 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 K-40 3719 3719 597.6 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 MN-54
<85.39 11.71 85.39 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 CO-58
<78.2
-8.976 78.2 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 FE-59
<168.4
-1.771 168.4 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 CO-60
<73.11
-12.54 73.11 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 ZN-65
<155.3
-56.83 155.3 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 NB-95
<79.9 21.3 79.9 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 ZR-95
<123.2
-43.11 123.2 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 1-131
<116.3
-3.424 116.3 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 CS-134
<77.89
-10.77 77.89 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 CS-137
<76.43
-17.46 76.43 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 BA-140
<366.6 207.3 366.6 pCi/kgWet Fish PALISADES COMMON CARP 5/24/2024 8:00 LA-140
<138.2 42.81 138.2 pCi/kgWet
Plant: Palisades Year: 2024 Page 76 of 98 Annual Radiological Environmental Operating Report Page 51 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Fish PALISADES DRUM 5/24/2024 8:00 K-40 2716 2716 626 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 MN-54
<56.24 5.256 56.24 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 CO-58
<57.2
-14.78 57.2 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 FE-59
<105.5 10.48 105.5 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 CO-60
<65.9 3.035 65.9 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 ZN-65
<117.6
-101.1 117.6 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 NB-95
<63.77 44.68 63.77 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 ZR-95
<105.3
-9.771 105.3 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 1-131
<90.8 8.409 90.8 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 CS-134
<57.96
-41.22 57.96 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 CS-137
<60.85
-16.34 60.85 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 BA-140
<275.6 60.02 275.6 pCi/kgWet Fish PALISADES DRUM 5/24/2024 8:00 LA-140
<78.58 8.948 78.58 pCi/kgWet
Plant: Palisades Year: 2024 Page 77 of 98 Annual Radiological Environmental Operating Report Page 52 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 K-40 4077 4077 529.5 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 MN-54
<46.48 13.23 46.48 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 CO-58
<39.87
-9.836 39.87 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 FE-59
<95.15 2.153 95.15 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 CO-60
<43.2 11.27 43.2 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 ZN-65
<114.1
-48.64 114.1 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 NB-95
<49.54 2.588 49.54 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 ZR-95
<67.46
-30.4 67.46 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 1-131
<65.92 27.79 65.92 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 CS-134
<51.15 6.64 51.15 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 CS-137
<40.2 7.696 40.2 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 BA-140
<186.9 27.77 186.9 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 LA-140
<69.34 9.08 69.34 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 4/18/2024 10:25 TH-228 123.1 123.1 74.24 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 K-40 3429 3429 574.7 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 MN-54
<57.71 11.86 57.71 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/2024 11:20 CO-58
<52.17 9.766 52.17 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 FE-59
<108.7 0.3964 108.7 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 CO-60
<58.38
-12.7 58.38 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 ZN-65
<113.3
-44.31 113.3 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 NB-95
<48.96
-10.32 48.96 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 ZR-95
<101.5 47.76 101.5 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/2024 11:20 1-131
<82.58
-16.53 82.58 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/2024 11:20 CS-134
<66.46 27.24 66.46 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 CS-137
<61.76 13.08 61.76 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/2024 11:20 BA-140
<271.8 104.2 271.8 pCi/kg Dry
Plant: Palisades Year: 2024 Page 78 of 98 Annual Radiological Environmental Operating Report Page 53 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Sediment/Silt NORTH SEDIMENT 4/18/2024 11:20 LA-140
<91.43
-20.13 91.43 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 4/18/202411:20 TH-228 100.2 100.2 88.45 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 K-40 4970 4970 684.8 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 MN-54
<56.28 7.171 56.28 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 CO-58
<52.31
-29.89 52.31 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 FE-59
<122.8 25.36 122.8 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 CO-60
<62.78
-7.101 62.78 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 ZN-65
<141
-33.45 141 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 NB-95
<61.4 2.93 61.4 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 ZR-95
<102.6
-23.72 102.6 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 1-131
<102.9 13.62 102.9 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 CS-134
<80.94 52.92 80.94 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 CS-137
<66.56 26.83 66.56 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 BA-140
<285.8 47.74 285.8 pCi/kg Dry Sediment/Silt SOUTH SEDIMENT 10/17/202413:38 LA-140
<87.05
-16.83 87.05 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 K-40 6097 6097 595.5 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 MN-54
<69.67 29.95 69.67 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 CO-58
<54.75
-36.99 54.75 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 FE-59
<146.2 56.51 146.2 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 CO-60
<61.14
-26.8 61.14 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 ZN-65
<177.8 104 177.8 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 NB-95
<72.54 27.01 72.54 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 ZR-95
<107.2
-23.12 107.2 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 1-131
<100.9
-23.08 100.9 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 CS-134
<62.39
-27.33 62.39 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 CS-137
<69.58 27.43 69.58 pCi/kg Dry
Plant: Palisades Year: 2024 Page 79 of 98 Annual Radiological Environmental Operating Report Page 54 of 68 REMP Sample Results Matrix Station Start Date Analysis Reportable Result Activity MDC Units Sediment/Silt NORTH SEDIMENT 10/17/202414:19 BA-140
<256.5
-78.98 256.5 pCi/kg Dry Sediment/Silt NORTH SEDIMENT 10/17/202414:19 LA-140
<92.67
-0.09935 92.67 pCi/kg Dry Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 GR-B
<2.16 2.03 2.16 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 H-3 (DIST)
<645 172 645 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 K-40 27.14 27.14 15.36 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 MN-54
<1.654
-0.859 1.654 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 C0-58
<2.109
-0.1044 2.109 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 FE-59
<5.634 6.089 5.634 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 C0-60
<1.764 0.1247 1.764 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 ZN-65
<3.556
-2.039 3.556 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 NB-95
<2.176 0.4665 2.176 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 ZR-95
<3.679
-0.4865 3.679 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 1-131
<19.91 5.583 19.91 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 CS-134
<1.864 0.2792 1.864 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 CS-137
<1.731 0.02503 1.731 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 BA-140
<27.86 18.46 27.86 pCi/L Surface Water LAKE IN 1/1/2024 0:00 2/1/2024 0:00 LA-140
<9.52 1.858 9.52 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 GR-B 4.94 4.94 2.02 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 H-3 (DIST)
<644
-23.5 644 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 MN-54
<1.832
-0.6195 1.832 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 C0-58
<2.096
-0.5244 2.096 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 FE-59
<5.008 1.736 5.008 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 C0-60
<1.84 0.2103 1.84 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 ZN-65
<3.853
-1.635 3.853 pCi/L
Plant: Palisades Year: 2024 Page 80 of 98 Annual Radiological Environmental Operating Report Page 55 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 NB-95
<2.346 1.426 2.346 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 ZR-95
<3.96 1.036 3.96 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 1-131
<17.9 1.708 17.9 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 CS-134
<1.991 0.3842 1.991 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 CS-137
<1.93 0.1669 1.93 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 BA-140
<25.49 5.112 25.49 pCi/L Surface Water LAKE IN 2/1/2024 0:00 3/1/2024 0:00 LA-140
<7.855 5.315 7.855 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 GR-B
<2.53 2.15 2.53 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 H-3 (DIST)
<643
-30.3 643 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 MN-54
<3.473 1.203 3.473 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 CO-58
<3.5
-0.0143 3.5 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 FE-59
<7.851
-0.6573 7.851 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 CO-60
<3.316 0.6684 3.316 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 ZN-65
<7.301 1.613 7.301 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 NB-95
<3.789
-1.937 3.789 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 ZR-95
<5.61
-4.084 5.61 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 1-131
<24.73 5.727 24.73 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 CS-134
<3.602 2.101 3.602 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 CS-137
<3.19 0.1802 3.19 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 BA-140
<36.68
-13.27 36.68 pCi/L Surface Water LAKE IN 3/1/2024 0:00 4/1/2024 0:00 LA-140
<12.11
-7.551 12.11 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 GR-B
<2.59 1.04 2.59 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 H-3 (DIST)
<755
-11.3 755 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 MN-54
<2.212
-0.01796 2.212 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 CO-58
<2.587
-0.2893 2.587 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 FE-59
<6.185 1.612 6.185 pCi/L
Plant: Palisades Year: 2024 Page 81 of 98 Annual Radiological Environmental Operating Report Page 56 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 CO-60
<2.082 0.13 2.082 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 ZN-65
<4.536
-2.613 4.536 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 NB-95
<2.604
-0.03549 2.604 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 ZR-95
<4.586 0.2356 4.586 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 1-131
<20.19 2.133 20.19 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 CS-134
<2.346 0.3268 2.346 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 CS-137
<2.153 0.2355 2.153 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 BA-140
<32.15 7.802 32.15 pCi/L Surface Water LAKE IN 4/1/2024 0:00 5/1/2024 0:00 LA-140
<12.05 3.694 12.05 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 GR-B 3.77 3.77 2.18 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 H-3 (DIST)
<616
-8.6 616 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 MN-54
<2.053 0.2178 2.053 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 CO-58
<2.405
-0.5432 2.405 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 FE-59
<5.645 2.309 5.645 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 CO-60
<2.212 0.16 2.212 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 ZN-65
<4.247
-1.53 4.247 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 NB-95
<2.418
-0.3659 2.418 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 ZR-95
<4.23 0.1047 4.23 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 1-131
<17.52 3.77 17.52 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 CS-134
<2.181
-0.1121 2.181 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 CS-137
<2.089 1.481 2.089 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 BA-140
<25.59 1.172 25.59 pCi/L Surface Water LAKE IN 5/1/2024 0:00 6/1/2024 0:00 LA-140
<8.809 2.191 8.809 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 GR-B 2.88 2.88 2.38 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 H-3 (DIST)
<681
-53.8 681 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 MN-54
<1.613
-0.05746 1.613 pCi/L
Plant: Palisades Year: 2024 Page 82 of 98 Annual Radiological Environmental Operating Report Page 57 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 CO-58
<1.789
-0.6036 1.789 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 FE-59
<4.118 1.965 4.118 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 CO-60
<1.778 0.7692 1.778 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 ZN-65
<3.39
-3.339 3.39 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 NB-95
<1.886 0.7691 1.886 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 ZR-95
<3.315 1.116 3.315 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 1-131
<7.54 0.02232 7.54 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 CS-134
<1.866 0.6241 1.866 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 CS-137
<1.771 1.033 1.771 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 BA-140
<15.07
-1.258 15.07 pCi/L Surface Water LAKE IN 6/1/2024 0:00 7/1/2024 0:00 LA-140
<4.751 0.4275 4.751 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 GR-B
<2.57 2.1 2.57 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 H-3 (DIST)
<578
-13 578 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 MN-54
<1.698
-0.9176 1.698 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 CO-58
<2.026 0.002149 2.026 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 FE-59
<4.48 0.8392 4.48 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 CO-60
<1.83
-0.02428 1.83 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 ZN-65
<3.672 0.1094 3.672 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 NB-95
<2.056 0.3785 2.056 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 ZR-95
<3.828 1.677 3.828 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 1-131
<10.69 2.257 10.69 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 CS-134
<1.989 1.021 1.989 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 CS-137
<1.834 0.7748 1.834 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 BA-140
<17.74
-3.529 17.74 pCi/L Surface Water LAKE IN 7/1/2024 0:00 8/1/2024 0:00 LA-140
<5.621
-2.129 5.621 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 GR-B
<2.36 2.11 2.36 pCi/L
Plant: Palisades Year: 2024 Page 83 of 98 Annual Radiological Environmental Operating Report Page 58 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 H-3 (DIST)
<318 56.6 318 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 MN-54
<1.981 1.016 1.981 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 CO-58
<2.153
-0.7129 2.153 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 FE-59
<5.033 0.5149 5.033 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 CO-60
<2.285 1.381 2.285 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 ZN-65
<4.183
-2.792 4.183 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 NB-95
<2.274 0.7781 2.274 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 ZR-95
<4.256 2.617 4.256 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 1-131
<12.46
-10.07 12.46 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 CS-134
<2.173 1.07 2.173 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 CS-137
<2.001 0.1724 2.001 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 BA-140
<21.82
-9.837 21.82 pCi/L Surface Water LAKE IN 8/1/2024 0:00 9/3/2024 0:00 LA-140
<7.375
-1.239 7.375 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 GR-B
<2.44 2.21 2.44 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 H-3 (DIST)
<594
-31.8 594 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 K-40 29.52 29.52 14.17 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 MN-54
<1.636 0.5667 1.636 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 CO-58
<1.803 0.06437 1.803 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 FE-59
<3.652
-1.947 3.652 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 CO-60
<1.832 1.096 1.832 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 ZN-65
<3.267
-2.402 3.267 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 NB-95
<1.929 0.8222 1.929 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 ZR-95
<3.233
-0.1791 3.233 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 1-131
<9.327
-2.758 9.327 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 CS-134
<1.773 0.6933 1.773 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 CS-137
<1.73
-0.2497 1.73 pCi/L
Plant: Palisades Year: 2024 Page 84 of 98 Annual Radiological Environmental Operating Report Page 59 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 BA-140
<16.32 0.5715 16.32 pCi/L Surface Water LAKE IN 9/3/2024 0:00 10/1/2024 0:00 LA-140
<5.138
-1.484 5.138 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 GR-B 5.15 5.15 3.78 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 H-3 (DIST)
<582 215 582 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 MN-54
<1.648 0.2239 1.648 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 CO-58
<2.133 0.3128 2.133 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 FE-59
<4.815 2.429 4.815 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 CO-60
<1.818 0.3319 1.818 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 ZN-65
<3.944
-0.4169 3.944 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 NB-95
<2.38 1.771 2.38 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 ZR-95
<3.715 0.1793 3.715 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 1-131
<16.47 1.898 16.47 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 CS-134
<1.791
-0.7665 1.791 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 CS-137
<1.78
-0.1178 1.78 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 BA-140
<23.95 1.116 23.95 pCi/L Surface Water LAKE IN 10/1/2024 0:00 11/1/2024 0:00 LA-140
<7.845
-1.654 7.845 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 GR-B
<2.56 1.61 2.56 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 H-3 (DIST)
<570 45.6 570 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 MN-54
<1.528
-1.035 1.528 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 CO-58
<1.841
-0.8534 1.841 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 FE-59
<4.823 1.985 4.823 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 CO-60
<1.677 0.09567 1.677 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 ZN-65
<3.58
-4.79 3.58 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 NB-95
<2.197 1.631 2.197 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 ZR-95
<3.568
-0.2648 3.568 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 1-131
<13.42
-5.406 13.42 pCi/L
Plant: Palisades Year: 2024 Page 85 of 98 Annual Radiological Environmental Operating Report Page 60 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 CS-134
<1.802 0.7204 1.802 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 CS-137
<1.709 0.2727 1.709 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 BA-140
<21.95
-4.466 21.95 pCi/L Surface Water LAKE IN 11/1/2024 0:00 12/1/2024 0:00 LA-140
<7.906
-1.139 7.906 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 GR-B 5.05 5.05 3.86 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 H-3 (DIST)
<563
-156 563 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 MN-54
<2.244 0.2191 2.244 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 CO-58
<2.566 1.162 2.566 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 FE-59
<5.153
-2.605 5.153 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 CO-60
<2.341 1.562 2.341 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 ZN-65
<4.55
-3.265 4.55 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 NB-95
<2.493
-0.2763 2.493 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 ZR-95
<4.538
-0.3501 4.538 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 1-131
<14.78
-1.852 14.78 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 CS-134
<2.39 0.1834 2.39 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 CS-137
<2.063
-1.296 2.063 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 BA-140
<24.48
-9.588 24.48 pCi/L Surface Water LAKE IN 12/1/2024 0:00 1/1/2025 0:00 LA-140
<7.824
-1.958 7.824 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 GR-B
<2.14 1.78 2.14 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 H-3 (DIST)
<645
-291 645 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 MN-54
<1.922 0.9616 1.922 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 CO-58
<2.067
-0.5361 2.067 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 FE-59
<5.498 0.4598 5.498 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 CO-60
<1.832
-0.3657 1.832 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 ZN-65
<3.816
-2.384 3.816 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 NB-95
<2.433 0.6357 2.433 pCi/L
Plant: Palisades Year: 2024 Page 86 of 98 Annual Radiological Environmental Operating Report Page 61 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 ZR-95
<3.832
-1.287 3.832 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 1-131
<19.45 4.971 19.45 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 CS-134
<1.969 0.3053 1.969 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 CS-137
<1.824
-0.6138 1.824 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 BA-140
<28.06 5.693 28.06 pCi/L Surface Water LUDINGTON CONTROL 1/1/2024 0:00 2/1/2024 0:00 LA-140
<8.922
-5.744 8.922 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 GR-B 2.34 2.34 1.94 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 H-3 (DIST)
<639
-135 639 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 MN-54
<1.745
-0.2842 1.745 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 CO-58
<2.128 0.4685 2.128 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 FE-59
<4.903 2.874 4.903 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 CO-60
<1.849 0.4609 1.849 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 ZN-65
<3.958
-2.184 3.958 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 NB-95
<2.237 0.0351 2.237 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 ZR-95
<4.11 1.664 4.11 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 1-131
<13.92
-4.436 13.92 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 CS-134
<1.958 0.1951 1.958 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 CS-137
<1.875 0.1536 1.875 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 BA-140
<21.65
-8.281 21.65 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 LA-140
<7.637 0.7717 7.637 pCi/L Surface Water LUDINGTON CONTROL 2/1/2024 0:00 3/1/2024 0:00 RA-226 51.1 51.1 35.41 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 GR-B
<2.45 1.9 2.45 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 H-3 (DIST)
<636
-169 636 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 MN-54
<2.43
-0.07526 2.43 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 CO-58
<2.703
-1.059 2.703 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 FE-59
<6.963 5.243 6.963 pCi/L
Plant: Palisades Year: 2024 Page 87 of 98 Annual Radiological Environmental Operating Report Page 62 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 CO-60
<2.611 1.964 2.611 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 ZN-65
<4.901
-2.246 4.901 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 NB-95
<3.167 1.723 3.167 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 ZR-95
<4.872
-1.21 4.872 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 1-131
<19.37 10.14 19.37 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 CS-134
<2.625 0.703 2.625 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 CS-137
<2.432 0.08099 2.432 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 BA-140
<29.98
-9.364 29.98 pCi/L Surface Water LUDINGTON CONTROL 3/1/2024 0:00 4/1/2024 0:00 LA-140
<12.15 2.322 12.15 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 GR-B
<2.54 1.78 2.54 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 H-3 (DIST)
<765
-338 765 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 MN-54
<2.075
-0.02721 2.075 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 CO-58
<2.404
-0.4133 2.404 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 FE-59
<5.729 1.744 5.729 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 CO-60
<2.222 1.097 2.222 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 ZN-65
<4.301
-2.663 4.301 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 NB-95
<2.582 0.702 2.582 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 ZR-95
<4.229
-0.2174 4.229 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 1-131
<19.84 1.01 19.84 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 CS-134
<2.248 0.5213 2.248 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 CS-137
<2.034
-0.4816 2.034 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 BA-140
<27.81
-3.034 27.81 pCi/L Surface Water LUDINGTON CONTROL 4/1/2024 0:00 5/1/2024 0:00 LA-140
<12.11 4.41 12.11 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 GR-B 3.88 3.88 2.49 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 H-3 (DIST)
<611
-186 611 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 MN-54
<1.245 0.3662 1.245 pCi/L
Plant: Palisades Year: 2024 Page 88 of 98 Annual Radiological Environmental Operating Report Page 63 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 CO-58
<1.416 0.5108 1.416 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 FE-59
<3.476 0.3771 3.476 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 CO-60
<1.355 0.8389 1.355 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 ZN-65
<2.702
-0.5669 2.702 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 NB-95
<1.438
-0.3553 1.438 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 ZR-95
<2.341
-1.068 2.341 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 1-131
<11.76
-3.47 11.76 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 CS-134
<1.28 0.3238 1.28 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 CS-137
<1.173 0.1622 1.173 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 BA-140
<16.91 6.227 16.91 pCi/L Surface Water LUDINGTON CONTROL 5/1/2024 0:00 6/1/2024 0:00 LA-140
<5.911 1.655 5.911 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 GR-B
<2.44 2.06 2.44 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 H-3 (DIST)
<651 100 651 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 MN-54
<1.912 1.291 1.912 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 CO-58
<2.167 0.5015 2.167 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 FE-59
<4.92 2.972 4.92 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 CO-60
<1.969 0.4598 1.969 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 ZN-65
<4.062
-1.116 4.062 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 NB-95
<2.28 0.9051 2.28 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 ZR-95
<3.941 0.07118 3.941 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 1-131
<14.97 1.412 14.97 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 CS-134
<2.055 1.131 2.055 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 CS-137
<1.948 1.127 1.948 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 BA-140
<23.49 1.995 23.49 pCi/L Surface Water LUDINGTON CONTROL 6/1/2024 0:00 7/1/2024 0:00 LA-140
<7.681 2.017 7.681 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 GR-B
<2.32 1.45 2.32 pCi/L
Plant: Palisades Year: 2024 Page 89 of 98 Annual Radiological Environmental Operating Report Page 64 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 H-3 (DIST)
<580 273 580 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 MN-54
<1.517
-0.2446 1.517 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 CO-58
<1.879 0.6413 1.879 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 FE-59
<4.098 0.7483 4.098 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 CO-60
<1.639 0.5552 1.639 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 ZN-65
<3.062
-3.056 3.062 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 NB-95
<1.987 1.185 1.987 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 ZR-95
<3.442 2.425 3.442 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 1-131
<16.32
-7.429 16.32 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 CS-134
<1.633
-0.3807 1.633 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 CS-137
<1.564 0.2402 1.564 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 BA-140
<23.09 5.639 23.09 pCi/L Surface Water LUDINGTON CONTROL 7/1/2024 0:00 8/1/2024 0:00 LA-140
<7.646 0.2243 7.646 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 GR-B
<2.51 2.01 2.51 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 H-3 (DIST)
<317 48.3 317 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 MN-54
<1.875
-0.617 1.875 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 CO-58
<2.269 0.4904 2.269 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 FE-59
<5.407 0.4479 5.407 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 CO-60
<2.116 1.057 2.116 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 ZN-65
<4.24
-1.26 4.24 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 NB-95
<2.393 1.057 2.393 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 ZR-95
<4.014
-0.3509 4.014 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 1-131
<18.01 3.627 18.01 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 CS-134
<2.084 0.4226 2.084 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 CS-137
<1.993 0.3148 1.993 pCi/L Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 BA-140
<26.16
-8.362 26.16 pCi/L
Plant: Palisades Year: 2024 Page 90 of 98 Annual Radiological Environmental Operating Report Page 65 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 8/1/2024 0:00 9/1/2024 0:00 LA-140
<10.59 2.304 10.59 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 GR-B 3.69 3.69 2.06 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 H-3 (DIST)
<607 69.3 607 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 K-40 27.11 27.11 17.65 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 MN-54
<1.976 0.3676 1.976 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 CO-58
<2.257
-0.4213 2.257 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 FE-59
<5.413 4.864 5.413 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 CO-60
<2.155
-0.6957 2.155 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 ZN-65
<4.304 1.55 4.304 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 NB-95
<2.33 0.251 2.33 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 ZR-95
<3.919
-0.5462 3.919 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 1-131
<14.14 7.571 14.14 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 CS-134
<2.007
-1.037 2.007 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 CS-137
<1.879
-0.5015 1.879 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 BA-140
<22.19
-2.313 22.19 pCi/L Surface Water LUDINGTON CONTROL 9/1/2024 0:00 10/1/2024 0:00 LA-140
<8.249 1.847 8.249 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 GR-B 2.93 2.93 2.73 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 H-3 (DIST)
<587 159 587 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 MN-54
<1.901
-0.778 1.901 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 CO-58
<2.038
-0.8339 2.038 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 FE-59
<5.27
-0.9952 5.27 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 CO-60
<2.167 1.017 2.167 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 ZN-65
<3.97
-4.127 3.97 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 NB-95
<2.432 0.5299 2.432 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 ZR-95
<3.93 0.9321 3.93 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 1-131
<15.5
-7.871 15.5 pCi/L
Plant: Palisades Year: 2024 Page 91 of 98 Annual Radiological Environmental Operating Report Page 66 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 CS-134
<2.055 0.3078 2.055 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 CS-137
<1.916
-0.4529 1.916 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 BA-140
<24.86 1.436 24.86 pCi/L Surface Water LUDINGTON CONTROL 10/1/2024 0:00 11/1/2024 0:00 LA-140
<8.099
-4.887 8.099 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 GR-B 2.57 2.57 2.53 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 H-3 (DIST)
<548 86.6 548 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 MN-54
<1.458 0.07088 1.458 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 CO-58
<1.728 0.2103 1.728 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 FE-59
<4.034 0.7644 4.034 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 CO-60
<1.625 0.8193 1.625 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 ZN-65
<2.851
-1.576 2.851 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 NB-95
<1.835 2.9E-05 1.835 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 ZR-95
<3.128
-1.39 3.128 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 1-131
<13.11
-7.786 13.11 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 CS-134
<1.661 0.06317 1.661 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 CS-137
<1.56
-0.3385 1.56 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 BA-140
<19.99
-8.792 19.99 pCi/L Surface Water LUDINGTON CONTROL 11/1/2024 0:00 12/1/2024 0:00 LA-140
<6.739 1.619 6.739 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 GR-B
<2.14 1.91 2.14 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 H-3 (DIST)
<563 129 563 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 MN-54
<1.663 0.6971 1.663 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 CO-58
<1.882
-0.1191 1.882 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 FE-59
<4.572 1.167 4.572 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 CO-60
<1.793 1.027 1.793 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 ZN-65
<3.143
-3.628 3.143 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 NB-95
<2.059 0.733 2.059 pCi/L
Plant: Palisades Year: 2024 Page 92 of 98 Annual Radiological Environmental Operating Report Page 67 of 68 REMP Sample Results Matrix Station Start Date Stop Date Analysis Reportable Result Activity MDC Units Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 ZR-95
<3.409
-0.2569 3.409 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 1-131
<16.85
-8.804 16.85 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 CS-134
<1.721
-0.4208 1.721 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 CS-137
<1.551
-0.7187 1.551 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 BA-140
<25.1
-2.113 25.1 pCi/L Surface Water LUDINGTON CONTROL 12/1/2024 0:00 1/1/2025 0:00 LA-140
<8.133
-1.035 8.133 pCi/L
Plant: Palisades Year: 2024 Loaction Qtrly Location Baseline
'BQl (mrem) 1 10.72 2
14.12 3
11.14 6
10.72 7
9.71 8
10.06 13 9.48 14 8.36 15 9.08 16 9.15 17 8.79 18 9.79 19 9.45 20 9.38 21 9.58 23 11.15 24 11.69 4-21 10.39 5-21 11.83 9-21 10.11 11-21 (cont) 11.88 Annual Radiological Environmental Operating Report BQl+
MDD/
(mrem) 12.27 16.02 12.81 12.29 11.40 11.70 10.78 9.97 10.65 10.75 10.22 11.65 11.04 11.09 10.95 12.70 13.55 12.04 14.06 12.12 13.61 REMP Sample Results Quarterly Dosimetry Results 2024 Normalized Net Dose, MQx (mrem/std. Qtr)
Annual
- Baseline, Qt Q2 Q3*
Q4*
BA11l (mrem) 10.58 9.66 4.54 5.35 42.85 13.57 12.77 8.39 8.96 56.40 10.92 9.77 5.09 6.06 44.46 10.26 9.46 4.34 5.74 42.90 9.52 8.62 3.52 4.74 38.74 9.96 8.62 3.87 4.67 40.18 9.75 8.40 3.22 3.95 37.87 8.68 7.25 2.36 3.25 33.36 9.08 7.83 3.00 3.72 36.20 9.46 8.48 3.60 4.00 36.49 8.54 7.97 2.77 3.78 35.01 9.84 8.93 3.93 4.69 39.05 9.43 8.48 3.65 4.01 37.68 9.24 8.53 3.65 4.11 37.40 9.63 8.60 3.77 4.31 38.26 11.55 10.63 5.31 5.31 44.51 11.20 10.96 6.62 6.62 46.58 9.86 9.07 4.19 5.33 41.57 11.49 10.81 5.92 6.12 47.33 9.71 8.98 3.58 4.46 40.42 11.77 10.58 5.69 6.48 47.51 BA+ MDDA12)
(mrem) 45.78 59.16 47.47 45.47 42.19 42.30 40.29 36.29 38.19 38.51 38.17 40.91 40.14 39.67 39.49 47.05 49.35 42.43 48.07 40.63 49.16 I
Page 93 of 98 Page 68 of 68 Annual Facility Dose, FA (mrem)
ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Transient dosimeters were shipped with the new quarter's dosimeters and returned with the previous quarter's dosimeters. Therefore, almost the entire dose received was from transportation vs calculating a daily dose from a vault study. This resulted in a lower transient/
daily dose being subtracted from the control dose.
1 B = The estimated mean background radiation dose at each field monitoring location based on historical measurements, excluding any dose contribution from the monitoring facility.
MOD= The smallest amount of facility related dose at each monitoring location above the baseline background dose that can be reliably detected by an environmental dosimetry system.
Plant: Palisades Year: 2024 I
Page 94 of 98 Annual Radioloaical Environmental Operatina Report Page 1 of 3 lnterlaboratory Comparison Program Results 1.0 Summary Summary of Results - lnterlaboratory Comparison Program (ICP)
The TBE Laboratory analyzed Performance Evaluation (PE) samples of air particulate (AP), air iodine, milk, soil, vegetation, and water matrices that represent test & matrix combinations available for REMP programs. The PE samples supplied by Analytics Inc., Environmental Resource Associates (ERA) and Department of Energy (DOE) Mixed Analyte Performance Evaluation Program (MAPEP), were evaluated against the following pre-set acceptance criteria:
A.
Analytics Evaluation Criteria Analytics' evaluation report provides a ratio of TBE's result and Analytics' known value. Since flag values are not assigned by Analytics, TBE evaluates the reported ratios based on internal QC requirements based on the DOE MAPEP criteria.
B.
ERA Evaluation Criteria ERA's evaluation report provides an acceptance range for control and warning limits with associated flag values. ERA's acceptance limits are established per the US EPA, National Environmental Laboratory Accreditation Conference (NELAC), state-specific Performance Testing (PT) program requirements or ERA's SOP for the Generation of Performance Acceptance Limits, as applicable. The acceptance limits are either determined by a regression equation specific to each analyte or a fixed percentage limit promulgated under the appropriate regulatory document.
C.
DOE Evaluation Criteria MAPEP's evaluation report provides an acceptance range with associated flag values. MAPEP defines three levels of performance:
Acceptable (flag = "A") - result within +/- 20% of the reference value Acceptable with Warning (flag = "W") - result falls in the +/- 20% to +/- 30% of the reference value Not Acceptable (flag = "N") - bias is greater than 30% of the reference value Note: The Department of Energy (DOE) Mixed Analyte Performance Evaluation Program (MAPEP) samples are created to mimic conditions found at DOE sites which do not always resemble typical environmental samples obtained at commercial nuclear power facilities.
For the TBE laboratory, 124 out of 131 analyses performed met the specified acceptance criteria. Seven analyses did not meet the specified acceptance criteria and were addressed through the TBE Corrective Action Program. A summary is found below:
- 1.
The MAPEP February 2024 Soil Ni-63 result was evaluated as Not Acceptable. TBE's reported value was 294 Bq/kg and the known result was 1130 Bq/kg (range 791 - 1469).
The sample was reprepped by a different (senior) lab technician with results of 1120 &
1250 Bq. It was determined that there was a difference between the two techs during the sample prep (technique) and the procedure was revised to reflect these differences
Plant: Palisades Year: 2024 Annual Radioloaical Environmental Operatina Report lnterlaboratory Comparison Program Results including using a specific aliquot amount. (NCR 23-08)
I Page 95 of 98 Page 2 of 3
- 2.
The MAPEP February 2024 vegetation Sr-90 result was evaluated as Not Acceptable.
The reported value was 0.05 Bq (not detected) and the known result was a "false positive".
This was considered to be a statistical failure because TBE's reported result with 3 times the uncertainty resulted in a slightly positive net result (0.03194 Bq/kg). The reported result was significantly below TBE's average detection limit for vegetation samples.
(NCR 23-09)
- 3.
The ERA RAD February 2024 water Ba-133 result was evaluated as Not Acceptable. The reported value was 26.0 pCi/L and the known was 22.3 (acceptance range 17.1 -25.8 pCi) or 117% of the known (acceptable for TBE QC). The sample was used as the workgroup duplicate with a result of 25.4 (114%). The sample had also been counted on a different detector with a result of 21.9 (98% ). The was TBE's first failure for Ba-133.
(NCR 23-10)
- 4.
The MAPEP August 2024 soil Fe-55 result was evaluated as Not Acceptable. The reported value was 346 Bq/kg and the known result was 1280 (acceptance range of 896-1664 Bq/kg). This was TBE's initial evaluation for Fe-55 in soils. The result was received at the end of December and the root cause in under investigation. No client samples were associated with this cross-check. (CAR 23-31)
- 5.
The Analytics September 2024 milk Sr-90 result was evaluated as Not Acceptable. The reported result was 7.28 pCi/L and the known result was 12.8 (57% of known). This sample was used as the workgroup duplicate and the carrier yields for both samples were 107% and 75%. The LCS recovery for the workgroup was at 106%. The ERA drinking water Sr-90 cross check that was analyzed around the same time was acceptable at 108%. There was no explanation for the failure. This is the first low biased failure for Sr-90 milk. The last failure (high) was in 2016. (NCR 23-24)
- 6.
The ERA RAD October 2024 water Gross Alpha result was evaluated as Not Acceptable.
The reported result was 53.2 pCi/L and the known result was 70.6 (acceptable range of 54.0 - 87.2 pCi/L). The reported result was the workgroup duplicate and was within 75%
of the known value (within TBE QC range). The original result was 63.3 pCi/L (90% of the known). Because the LCS result was biased slightly high, the decision was made to report the lower value. (NCR 23-20)
- 7.
The ERA RAD October 2024 water 1-131 result was evaluated as Not Acceptable. The reported value was 23.5 pCi/L and the known result was 29.7 (acceptable range of 25.8 -
33.6) The reported result was 79% of the known, which is within the acceptable TBE QC range. The workgroup was reviewed with no anomalies found. The LCS/LCSD results were 109% and 86.1 %. The sample was not processed in a timely manner as per the ERA instructions which stated to analyze shortly after receipt due to the short half-life.
Going forward, the QA &/or Lab Mgr. will ensure that this analysis is started sooner.
(NCR 23-21)
The Inter-Laboratory Comparison Program provides evidence of "in control" counting systems and methods, and that the laboratories are producing accurate and reliable data.
Thermoluminescent dosimeters (TLDs) are analyzed by an offsite vendor, "Environmental Dosimetry Company" (EDC). The TLDs used are Panasonic 814 Environmental dosimeters. EDC implements an internal quality assurance program and audits the program annually. There were no findings from the 2024 audit. An external audit of EDC was performed in 2024 which also resulted in no identified
Plant: Palisades Year: 2024 I
Page 96 of 98 Annual Radioloaical Environmental Operatina Report Page 3 of 3 lnterlaboratory Comparison Program Results findings. Some of EDC's vendors also perform independent testing on the TLDs accuracy and precision. During 2024, 100% (72/72) of the individual dosimeters met the criterion for accuracy and precision. Also, 100% ( 12/12) of the dosimeter sets met the criterion for mean bias and precision and 100% (10/10) of independent blind testing passed the performance criteria for mean bias and precision.
Acceptance criteria for mean bias is +/-15% and for precision is +/-12.8% in accordance with EDC Quality System Manual
Plant: Palisades Year: 2024 I
Page 97 of 98 Annual Radiological Environmental Operating Report Page 1 of 2 ERRATA Data During the 2023 REMP inspection, it was identified that the collection dates in Table 21 of the 2023 AREOR were not correct for the Palisades Park Commercial Well location. Below is the original page and the corrected page.
Original Plant: Palisades Year: 2023 I Page 37 of 41 Annual Radioloaical Environmental Qperatina Report Page 13 of 14 Monitoring Results Tables
[Note 1) - This nuclide is naturally occurring and there is no ODCM required LLD.
Table 21, Offsite Groundwater - Gamma isotopic Analysis: Gamma Isotopic Units: pCi/L Location Collection Mn-54 Co-58 Fe-59 Co-60 Date Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 REQUIRED LLD 15 15 30 15 30 15 30 15 18 60 15 Pal Park Commercial 05/22/22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 06/13/22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 07/12/22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 08/15/22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 09/13/ 22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 10/03/22
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well
Plant: Palisades Year: 2024 I
Page 98 of 98 Annual Radiological Environmental Operating Report Page 2 of 2 ERRATA Data Corrected Plant: Palisades I
Year: 2023 I Page 37 of 41 Annual Radiological Environmental Operating Report Page 13 of 14 Monitoring Results Tables
[Note 1] - This nuclide is naturally occurring and there is no ODCM required LLD.
Table 21, Offsite Groundwater - Gamma isotopic Analysis: Gamma Isotopic Units: pCi/L Location Collection Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Date REQUIRED LLD 15 15 30 15 30 15 30 15 18 60 15 Pal Park Commercial 05/17/23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 06/ 12/ 23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 07/ 10/23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 08/ 01/ 23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 09/ 05/ 23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well Pal Park Commercial 10/ 02/ 23
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA Well