ML24106A210

From kanterella
Jump to navigation Jump to search

Letter and Safety Evaluation Report for Revision No. 25 of Certificate of Compliance No. 9235 for the Model No. NAC-STC Transportation Package
ML24106A210
Person / Time
Site: 07109235
Issue date: 04/16/2024
From: Yoira Diaz-Sanabria, Bernie White
Storage and Transportation Licensing Branch
To: Baldner H
NAC International
Shared Package
ML24106A157 List:
References
EPID L-2024-RNW-0009, EPID L-2024-LLA-0042
Download: ML24106A210 (3)


Text

April 16, 2024 Heath Baldner, Licensing Manager NAC International 2 Sun Court, Suite 220 Norcross, GA 30092

SUBJECT:

REVISION 25 OF CERTIFICATE OF COMPLIANCE NO. 9235 FOR THE MODEL NO. NAC-STC PACKAGE

Dear Heath Baldner:

By application dated November 30, 2023 (Agencywide Documents Access and Management System [ADAMS] Accession No. ML23345A152), NAC International, Inc. (NAC) requested consolidation of the safety analysis report associated with Certificate of Compliance (CoC) No.

9235, for the Model No. NAC-STC package and a renewal of the CoC for another 5-year term.

The approval constitutes authority to use the package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of Title 10 of the Code of Federal Regulations (CFR) Section 71.17, General License: NRC-Approved Package and 49 CFR 173.471.

Sincerely, Yoira Diaz Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9235 EPID Nos. L-2024-RNW-0009 and L-2024-LLA-0042

Enclosures:

1.

CoC No. 9235, Rev. No. 25 2.

Safety Evaluation Report cc w/encls. 1& 2:

R. Boyle, U.S. Department of Transportation J. Shuler, U.S. Department of Energy c\\o L. F. Gelder White, Bernard signing on behalf of Diaz-Sanabria, Yoira on 04/16/24

ML24106A157 (PKG), ML24106A210 (LTR,SER/Encl 2),

ML24106A209 (Encl 1)

OFFICE:

NMSS\\DFM NMSS\\DFM NMSS\\DFM NAME:

NDevaser SFigueroa BWhite for YDiazSanabria DATE:

4/15/2024 4/16/2024 4/16/2024 SAFETY EVALUATION REPORT Docket No. 71-9235 Model No. NAC-STC Certificate of Compliance No. 71-9235 Revision 25 EVALUATION By application dated November 30, 2024 (Agencywide Documents Access and Management System Accession No. ML23345A152) NAC International, Inc., requested consolidation of the safety analysis report associated with Certificate of Compliance (CoC, the certificate) No. 9235, for the Model No. NAC-STC package and a renewal of the CoC for another 5-year term.

CONDITIONS The following changes have been made to the Certificate:

Condition 3(a) was revised to reflect the applicants new address.

Condition 3(b) was revised to reflect the date of this consolidated application.

Condition 15 was revised to allow use of the previous certificates for a period of time.

Condition 16 was revised to allow use of the CoC for a 5-year period.

The consolidated application date was added to the REFERENCES section.

CONCLUSION These changes do not affect the ability of the package to meet the requirements of Title 10 of the Code of Federal Regulations Part 71.

Issued with Certificate of Compliance No. 9235, Revision No. 25.