ML22278A666
Text
N
- I:
~
IO I
~
H G
F E
D c
B A
8 812131-M-51 ll-15 (SH.11 C,2l SH. 2 OF M-51
($H.4 H,3) 10' EBB-108 T.
c.
'%' SBD-151 VENT 1076A 1077A
'Y DRW CGl2 C667C 1£1 Clil!S
[ill_!. _l'£U_.~
J
~t-~~
I e l.=i H.C.
1Fl27A TO SPENT FUEL POOL MAKE-UP AND SPRAY l.=i H.C.
TO RHR H.C.~r-lL
~
3"
~ H.C.
1fl2q 8
NOTE 33
~
y NE1AC s
7
- --~
RHR~
COMPARTMENTV
_J ISOLATION BYPASS
,--~
!SH.I E.41
'---REF!
~F~
NO AC s
@201 I
ILC
~
AC (zT\
'el I
L!J 14' GBB-103 6
ll-15 PV-C-1F051AlASl (SH.ll D,?l
(: ~
.IM5
~)
~L.
~
ISOLATION BYPASS
,--~
I
!SH.I G,7)
~ ~60~~
<f NO AC
~
s ll-16 HV-!F07qA(ASI
<SH.11 B,21
~
~
I' HBB-140 I' HBB-140 16' GBB-102 I
AC 20' M
')4'GBB-123 RHR HEAT Ei5fANGER
~*
~01
~~6~~\!!1-NOTE 46 20' 20" GBC-102
'5111~-~15s-->-~---1-.:lf--~-D~~7f'---==.,,,_----~1-7f'--~7"-~:'I'~
<SH.34 E.2l 2' SBD-151 2'
VENT
. !RI
'Y DRW 7
6 5
... l.. ~c s*
.._'*G-BB_-_13*0*~1--.._
L4c._~,
1 1Fl2ift~ GB[
7 4' GBB-11'4 KEYLOCK C601 l1e:_11 I
I
@C201 HS 4
C6ill
~ ~201 REFl4--io I
~-*--
HSS CG0! I
~201
~ '\.
1'l8 3
C61ill tilij I
REF 14-t --------------------I I
C601 I R'o/
I 0,, "-
I C018
{ii;),*
y I
~s0q r-TIS.,
15~
I 25 I SETPOINT UOIAJ r <SHOWN ON I P&IO M-25 SHT. !)
TO LIQUID RADWASTE M-62
<SH.I E,81 r---... l't----l*l'.. ----\ FG I' 580-151 1721\
DRAIN 1056A FC 2'
2' f---tl*---l--3DRAIN 1184A
!185A
- ~--~--~--~--~--~--~--~---,
I I
~
I I
3 I
NOTE 30 !
6' HBB-160 I
M-51 I
I AIMIOll£D IN PLACE (SH.4 E,71 I
- ~------------------------------~
CG01
~*
~
I CITS
_ ~
r#j/-Cf8 C801A
~
lJ,!,' SBD-151 1Fll2A IFll3A DRAIN GBB SBO 1--~
C201 QC
@---*2~1 __
20' GBC-103 C667C
- TO XR-036-llill REF 6
--~*
\SH.1 E,71 5
- i; C667C
~
~
I 4
1057A
~
m 0 :z
'Y DRW OE-ENERGIZED 4'
4' GBB-116 M-51 L.C.
<SH.I E,6)
~~~~~~~~~--~~--'1~0-'~HB~B~--14~0""---~~~~~~~~~~~-~*
!SH.I D,Bl 18' GBB-102
~
<SH.! C.81 OE-ENERGIZED
~
NOTE30 r-\'.l-:::::::::-::-:::"-:::"':7::::"""----"T------6~'~HB~B~-~13~q~-~JM~-5~l~
_L.../
BLIND FLANGE (SH.! B,6l t=:u v*
I
~_J
~..
~~---.
M....
3 y
DRW 2
2 REF No.
1 REFERENCE DRAWINGS BECHTEL No.
RESIDUAL HEAT REMOVAL FC 8031-M!-Ell-1030-F!.
~iftCTOR PROTECTION SYSTE 803!-M!-C7!-llill0-F!.
NUCLEAR BOILER SYSTEM FC 81il31-Hl-B21-1030-F1.
PROCESS INST PIPING AND TUBING DESIGN SPEC HPCI PUMP /TURBINE P&ID 803!-Ml-A61-4070-Ll.
8031-M-56 GE No.
72'!E630A 72'lE611AD 22A31'!2 76!E557AD 22A2864 7
PLANT LEAK DETECTION P&I 803!-M-25 8
PROCESS SAMPLING 803!-M-23 8031-M-5!FO 10 RHR SYSTEM LOOP DIAGRAMS 803l-Ml-Hl2-2040-E285. 164C5023 ll EMERGENCY SERVICE WATER P&ID 8031-M-ll
..!!!!!§!.
- 1. THIS IS A SEISMIC CLASS I SYSTEM EXCEPT AS NOTED.
- 2. THE GE MPL NUMBER FOR THIS SYSTEM IS E-11.
- 3. TEMPERATURE LEAK DETECTION IS SHOWN ON REFERENCE 7 TEMP INSTRUMENTS ARE INDEXED AS PART OF THIS P&!D 51 *
- 4. PSV-!05A & B ANO PSV-106A & 8 ARE THERMAL RELIEF VALVES.
- 5. ALL INSTRUMENT PIPING ANO TUBING SHALL BE INST AL LED IN ACCORDANCE WITH REFERENCE 5. FOR DEVIATIONS TO SLOPE CRITERIA SEE REF 12.
- 6. WHERE PRACTICAL, ALL LIGUIO LINES INSIDE THE PRIMARY CONTAINMENT SHALL BE SLOPED.
B. DELETED.
'!.DELETED.
- 10. DELETED.
- 11.
VACUUM BREAKERS PSV-101A & B ARE TO BE LOCATED AS CLOSE TO THE RELIEF VALVE DISCHARGE AS PRACTICAL.
- 12. VALVE LEAKOFF ANO DRAIN CONNECTIONS SHALL BE CAPPED 0 PLUGGED UNLESS SHOWN OTHERWISE.
- 13. ALARMS LAL-110A, C ANO E ARE LOCATED ON PANEL 1AC801.
ALARMS LAL-1108, 0 ANO F ARE LOCATED ON PANEL 1CC801.
- 14. DESIGN, FABRICATION, MATERIAL PROCUREMENT, ERECTION, AND TESTING FDR ALL PIPING, VALVES AND EQUIPMENT SHOWN WITHIN THE SYMBOL to-NOTE 141, AND FOR ALL PlPING AFTER THE LAST ISOLATION VALVE ON CAPPED VENTS, DRAINS &. TEST CONNECTIONS, HAY BE IN ACCORDANCE WITH THE REOUIREMENTS OF THE PIPING CLASS DESIGNATION DESIGN CODE 'D', WITH THE FOLLOWING EXCEPTIONS*
Col CLEANING REGUIREMENTS SHALL BE PER THE ORIGINAL CLAS DESIGNATION.
Cb) WELDING PROCEDURES TO BE USED SHALL BE AS REDUIREO PER THE ORIGINAL LINE CLASS DESIGNATION.
- 15. THE MAXIMUM DlFFERENT!AL PRESSURE ACROSS THE SUCTION STRAINERS SHALL NOT EXCEED THE AVAILABLE MARGIN ABOVE THE REQUIRED NPSH WHEN THE STRAINERS ARE FULLY FOULED.
- 16. PIPE CLASS BREAK IS AT FLUED HEAD. DESIGN PRESSURE, TEMPERATURE, ANO SERVICE CONDITIONS FOR THE FLUEO HEAD ARE THE SAME AS FOR ADJACENT ORYWELL PIPING.
lB. THE BYPASS VALVES AROUND EXCESS FLOW CHECK VALVES XV-1lill2A.B.C,0 ANO XV-103A,e.c.o ARE LOCKED CLOSED.
!'!. Fl-122A ANO IAC240 SHOULD BE LOCATEO ADJACENT TO EACH OTHER, ANO FI-!22B AND !BC240 SHOULD BE LOCATED ADJACENT TO EACH OTHER, SO THAT OPERATOR MAY OBSERVE THE FLOW INDICATION WHILE OPERATING TIE HEAT EXCHANGER LAY-UP VALVES.
- 20. NON-0 DRAIN ANO VENT LINES ANO CAPPED ENOS EXTENDING FROM SEISMIC CATEGORY I PIPING ARE SEISMIC CATEGORY l!A DOWNSTREAM OF THE LAST ISOLATION VALVE.
- FOR CONTINUATION OF NOTES, SEE SHEET 4 -
,-C80~--1 I~~
l~--~I L__ ____ J RHR PlM' ROOM FLOODING ALARM
- NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEETS 2 ANO H
F E
D c
8 INCORP. EC s2043q REV.! PER WO 4670031.
G'! "
ADDEO 3'HB0-115 ITO SPENT FUEL POOL MAKE-UP ANO B
1--+t=8+-SP_R_A_Y_>_AN_O~V-AL_v_E~1F-l_2q_._[_A_,e_1.~~~~~~~~~+=+.=.+-~
INCORP. ECR 14-00205 REV.1 PER WO C0257811.
ADDEO 4' &. 6' GBB-130 AND VALVE 6 1Fl26A ANO BLIND FLANGE. tG&F-51.
PARTIAL INCORP. ECR 14-00205 REV. 0 PER WO C0258033.
ADDED 6' HBC-353, 6' HB0-741 & 3'HB0-741 AND VALVES
- 1Fl24A & 1Fl27A AND HOSE COUPLINGS. [8,7&8J.
INCORP. ECR 08-004 75 REV. 0.
ADDEO REFERENCE TO NOTE 56.
[8,5&6J.
DESCRIPTION TABLE OF ADOIT!ONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID RESIDUAL HEAT REMOVAL
<UNIT 1) 1------L-l-M-ER-IC-K-GE-N-ER_A_T_IN_G_S_T-AT-l-ON-----tA EXEL.ON NUCLEAR CORP.
SCALE DRAWN
!GOS SHEET 2 OF 812131-M-51 6<3 1 CATEGORY Al
_J