s s--
7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION COMMONWEALTH EDISON COMPANY DOCKET NOS STN 50-456 AND STN 50-457 NOTICE OF CONSIDERATION OF ISSUANCE OF AMENDMENTS TO FACILITY OPERATING LipENSES. PROPOSED NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION. AND OPPORTUNITY FOR A HEARING.
The U.S. Nuclear Regulatory Commission (the Commisslon) is considering issuance of amendments to Facility Operating Licenses Nos. NPF-72 and NPF-77, issued to the Commonwealth Edison Company (Comed, the licensee), for Braidwood Station, Unit Nos.1 and 2, respectively, located in Will County, Illinois.
The proposed amendments would temporarily change the Technical Specifications (TS) to increase the upper temperature limit for the Ultimate Heat Sink (UHS) from 98 degrees Fahrenheit to 100 degrees Fahrenheit. The proposed temporary change would be in effect until September 30,1999.
Prolonged hot weather has resulted in sustained, elevated UHS temperatures at Braidwood Station. Continued hot weather may result in the UHS temperature exceeding 98 degrees Fahrenheit This would be expected to occur before the Commission could publish a Notice in the FEDERAL REGISTER that would allow 30 days for public comment.
Before issuance of the proposed license amendments, the Commission will have made findings required by the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations.
Pursuant to 10 CFR 50.91(a)(6) for amendments to be granted under exigent circumstances, the NRC staff must determine that the amendment request involves no 9908190018 990812 PDR ADOCK 05000456 ENCLOSURE
1 I,
- significant hazards consideration.' Under the Commission's regulations in 10 CFR 50.92, this means that operation of the facility in accordance with the proposed amendments would not (1) involve a significant increase in the probability or consequences of an accident previously' l-evaluated; or (2) create the possibility of a new or different kind of accident from any accident 1
l previously evaluated; or (3) involve a significant reduction in a margin of safety. As required by l
10 CFR 50.91(a), the licensee has provided its analysis of the issue of no significant hazards l
consideration, which is presented below:
Does the change involve a significant increase in the probability or consequences of an accident previously evaluated?
Analyzed accidents are assumed to be initiated by the failure of plant structures, systems or components. An inoperable UHS is not considered as an initiator of any analyzed events. The analyses for Braidwood Station, Units 1 and 2, assume an UHS temperature of 100 degrees Fahrenheit. Therefore, continued operation with an UHS temperature less than or equal to 100 degrees Fahrenheit, until September 30,1999,-
will not increase the consequences of an accident previously evaluated in the UFSAR
[ Updated Final Safety Analysis Report). The proposed change does not involve any physical alteration of plant systems, structures or components. A UHS temperature of up to 100 degrees Fahrenheit does not increase the failure rate of systems, structures or components because the systems, structures or components are rated and analyzed for operation ivith Essential Service water temperatures of 100 degrees Fahrenheit and the design albws for higher temperatures than at which they presently operate.
l The basis provided in Regulatory Guide 1.27 " Ultimate Heat Sink for Nuclear Power Plants," Revision 2, dated January 1976, was employed for the temperature analysis of l
the Braidwood Station UHS to implement General Design Criteria 44 and 2 of Appendix A to 10 CFR Part 50. This Regulatory Guide was employed for both the original design / licensing basis of the Braidwood Station UHS and a subsequent l
evaluation which investigated the potential for increasing the average water temperature of the UHS from less than or equal to 98 degrees Fahrenheit to less than or equal to 100 degrees Fahrenheit. The meteorological conditions chosen for the Braidwood Station UHS analysis utilized a synthetic 36-day perio:1 consisting of the most severe 5 days, most severe 1 day, and the most severe 30 days based on historical data. The heat loads selected for the UHS analysis considered one Braidwood Unit in a LOCA
[ Loss-of-Coolant Accident] condition concurrent with a Loss-of-Offsite Power (LOOP) l and the remaining Braidwood unit undergoing a normal plant shutdown. In the analysis, l
these heat loads are removed by the UHS using only SX [ essential service water]
pumps. The main condenser cooling pond is conservatively assumed not to be available at the start of the event. The analysis shows that with an initial UHS
. temperature of 100 degrees Fahrenheit, ' a required heat loads can be met for 30 days while meintaining essential senice wat<., '.emperatures at acceptable values.
Based on the above facts and reasoning, it has been demonstrated that the increase of j
the initial UHS temperature from less than or equal to 93 degrees Fahrenheit to less than or equal to 100 degrees Fahrenheit at the start of the design basis event will result in the continued ability of the equipment and components supplied by the SX system to perform their safety functions.
Therefore, increasing the average water temperature of the UHS from less than or equal to 98 degrees Fahrenheit to less than or equal to 100 degrees Fahrenheit in TS 3.7.9, has no impact on any analyzed accident. Raising this limit does not introduce any new equipment, equipment modifications, or any new or different modes of plant operation, nor does it affect the operational characteristics of any equipment or systems.
Therefore, these changes do not involve a significant increase in the probability or consequences of an accident previously evaluated.
Does the change create the possibility of a new or different kind of accident from any accident previously evaluated?
The proposed action does not involve a physical alteration of the units. There is no change being made to the parameters within which the units are operated that is not bounded by the analyses. There are no setpoints at whic.h protective or mitigative actions are initiated that are affected by this proposed action. This proposed action will not alter the manner in which equipment operation is initiated, nor will the function demands on credited equipment be changed. No alteration in the procedures that ensure the units remain within analyzed limits, is proposed, and no change is being made to procedures relied upon to respond to an off-normal event. As such, no new failure modes are being introduced. The proposed action does not alter assumptions made in the safety analysis; increasing the average water temperature of the UHS in TS 3.7.9 has no impact on plant operation. The proposed temperature limits does not introduce new failure mechanisms for systems, structures or components. The engineering analyses performed to support the UHS temperature increase provides the basis to conclude that the equipment is designed for the operation at elevated temperatures. In addition, design and construction codes provided sufficient margin to accommodate the proposed temperature change.
Therefore, this proposed amendment does not create the possibility of a new or different kind of accident from any accident previously evaluated.
Does the change involve a significant reduction in s margin of safety?
The proposed action allows operation with the UHS temperature less than or equal to 100 degrees Fahrenheit until September 30,1999. The margin defined by the difference in the assumed steady state SX temperature and the calculated SX
. i temperature profile integrated over the duration of the event is not significant impacted.
The margin of safety is determined by the design and qualification of the plant equipment, the operation of the plant within analyzed limits, and the point at which protective or mitigative actions are initiated. The proposed action does not impact these factors. There are no required design changes or equipment performance parameter changes associated with this change. No protection setpoints are affected as a result of this change. This temperature increase will not change the operational characteristics of the design of any equipment or system. All accident analysis assumptions and conditions will continue to be met. Thus, the proposed increase in temperature d,oes not involve a significant reduction in the margin of safety.
The NRC staff has reviewed the licensee's analysis and, based on this review, it appears that the three standards of 10 CFR 50.92(c) are satisfied. Therefore, the NRC staff proposes to determine that the amendments requested involve no significant hazards consideration.
The Commission is seeking public comments on this proposed determination. Any comments received within 14 days after the date of publication of this notice will be considered 1
in making any final determination.
Normally, the Commission will not issue the amendments until the expiration of the 14-day notice period. However, should circumstances change during the notice period, such that failure to act in a timely way would result, for example, in derating or shutdown of the facility, the Commission may issue the license amendments before the expiration of the 14-day notice period, provided that its final determination is that the amendments involve no significant hazards consideration. The final determination will consider all public and State comments received. Should the Commission take this action, it will publish in the FEDERAL REGISTER a notice of issuance. The Commission expects that the need to take this action will occur very infrequently.
Written comments may be submitted by mail to the Chief, Rules and Directives Branch, Division of Administrative Services, Office of Administration, U.S. Nuclear Regulatory
9-.
Commission, Washington, DC 20555-0001, and should cite the publication date and page number of this FEDERAL REGISTER notice. Written comments may also be delivered to Room 6D59, Two White Flint North,11545 Rockville Pike, Rockville, Maryland, from 7:30 a.m.
to 4:15 p.m. Federal workdays. Copies of written comments received may be examined at the NRC Public Document Room, the Gelman Building,2120 L Street, NW., Washington, DC.
The filing of requests for hearing and petitions for leave to intervene is discussed below.
By September 17, 1999, the licensee may file a request for a hearing with respect to issuance of the amendments to the subject facility operating liceases and any person whose interest may be aftocted by this proceeding and who wishes to participate as a party in the proceeding must file a written request for a hearing and a petition for leave to intervene.
Requests for a hearing and a petition for leave to intervene shall be filed in accordance with the Commission's " Rules of Practice for Domestic Licensing Proceedings" in 10 CFR Part 2.
Interested persons should consult a current copy of 10 CFR 2.714 which is available at the Commission's Public Document Room, the Gelman Building,2120 L Street, NW., Washington, DC, and at the local public document room located at the Wilmington Public Library, 201 S. Kankakee Street, Wilmington, Illinois 60481. If a request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Commission or by the Chairman of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition; and the Secretary or the riesignahd Atomic Safety and Licensing Board will issue a notice of hearing or an appropriate order.
As required by 10 CFR 2.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding, and how that interest may be affected by the results of the proceeding. The petition should specifically explain the reasons
1
- why intervention should be permitted with particular reference to the following factors: (1) the j
1 nature of the petitioners right under the Act to be made a party to the proceeding; (2) the nature and extent of the petitioners property, financial, or other interest in the proceeding; and
)
(3) the possible effect of any order which may be entered in the proceeding on the petitioners interest. The petition should also identify the specific aspect (s) of the subject matter of t,he proceeding as to which petitioner wishes to intervene. Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition without requesting leave of the Board up to 15 days prior to the first prehearing conference scheduled in the proceeding, but such an amended petition must satisfy the specificity requirements described above.
Not later than 15 days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene which must include a list of the contentions which are sought to be litigated in the matter. Each contention must consist of a specific statement of the issue of law or fact to be raised or controverted. In addition, the petitioner shall provide a brief explanation of the bases of the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing. The petitioner must also provide references to those specific sources and documents of which the petitioner is aware and on which the petitioner intends to rely to establish those facts or expert opinion.
Petitioner must provide sufficient information to show that a genuine dispute exists with the applicant on a material issue of law or fact. Contentions shall be limited to matters within the scope of the amendments under consideration. The contention must be one which, if proven, would entitle the petitioner to relief. A petitioner who fails to file such a supplement which
c,
. satisfies these requirements with respect to at least one contention will not be permitted to participate as a party.
Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene, and have the opportunity to participate fully in the conduct of the hearing, including the opportunity to present evidence and cross-ex, amine witnesses.
If the amendments are issued before the expiration of the 30-day hearing period, the Commission will make a final determination on the issue of no significant hazards consideration. If a hearing is requested, the final determination will serve to decide when the hearing is held.
If the final determination is that the amendments requested involve no significant hazards consideration, the Commission may issue the amendments and make them immediately effective, notwithstanding the request for a hearing. Any hearing held would take place after issuance of the amendments.
If the final determination is that the a nendments requested involve a significant hazards consideration, any hearing held would take place before the issuance of any amendments.
A request for a hearing or a petition for leave to intervene must be filed with the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, DC 20555-i 0001, Attention: Rulemakings and Adjudications Staff, or may be delivered to the Commission's Public Document Room, the Gelman Building,2120 L Street, NW., Washington, DC, by the above date. A copy of the petition should also be sent to the Office of the General Counsel, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, and to Ms.
Pamela B. Stroebel, Senior Vice President and General Counsel, Commonwealth Edison l
Company, P.O. Box 767, Chicago, Illinois 60690-0767, attomey for the licensee.
i
~.
I s
8-Nontimely filings of petitions for leave to intervene, amended petitions, supplemental petitions and/or requests for hearing will not be entertained absent a determination by the Commission, the presiding officer or the presiding Atomic Safety and Licensing Board that the petition and/or request should be granted based upon a balancing of the factors specifed in 10 CFR 2.714(a)(1)(i)-(v) and 2.714(d).
For further detalis with respect to this action, see the application for amendments dated July 30,1999, which is available for public inspection at the Commission's Public Document Room, the Gelman Building,2120 L Street, NW., Washington, DC, and at the local public document room, located at the Wilmington Public Library,201 S. Kankakee Street, Wilmington, Illinois 60481.
Dated at Rockville, Maryland, this 12* day of August.
FOR THE NUCLEAR REG LATORY COMMISSION Stewart Bailey, Proj __ " 92,_;, Section 2 Project Directorate 3 Division of Licensing Project Management Office of Nuclear Reactor Regulation