Text
.:.
...
p
' 9 SEP 1986
Docket / License:
50-334/DPR-66
Duquesne Light Company
ATTN:
Mr. J. D. Sieber
Vice President
Nuclear Operations
Post Office Box 4
Shippingport, Pennsylvania 15077
Gentlemen:
Subject:
Inspection 50-334/86-18
This refers to the resident safety inspection by Mr. W. Troskoski and Ms. A. Asars
on August 1-27, 1986 at the Beaver Valley Power Station, Unit 1, Shippingport,
The inspection consisted of document reviews, interviews, and ob-
servation of activities.
The findings were discussed with Mr. Sieber of your staff.
An augmented team inspection conducted an extensive review of the station's outar;e
recovery and startup activities to assess the effectiveness of your management
control systems. We found good overali improvement.in most areas.
Though improve-
ments were also made.in cold shutdown plant configuration control, the team ob-
served several problems that indicate additional efforts are still warranted to
achieve a high level of performance.
Your staff should review those program areas
where problems were identified during the outage.
Actions taken to upgrade and
strengthen those areas will be reviewed by us at a later date.
Apart from the above, it appears that certain of your activities were not conducted
in full compliance with NRC requirements, as set forth in the Notice of Violation
enclosed herewith as Appendix A.
The violation has been categorized by severity
level in accordance with the " General Statement of Policy and Procedure for NRC
Enforcement Actions," 10 CFR Part 2, Appendix C.
You are required to respond to
the enclosed Notice, and in preparing your response, you should follow the in-
structions specified therein.
The response directed by this letter and the accompanying Notice are not subject
to the clearance procedures of the Office of Management and Budget as required by
the Paperwork Reduction Act of 1980, PL 96-511.
Your cooperation is appreciated.
Sincerely,
Edward C. Wenzinger, Chief
Projects Branch No. 3
Division of Reactor Projects
2 0\\
h
8609230145 060909
ADOCK 05000334
G
I
I
- y,
+ .
.
Duquesne Light Company
2
Enclosures:
1.
Notice of Violation, Appendix A
2.
NRC Region I Inspection Report 50-334/86-18
cc w/encls:
C. E. Ewing, Manager, Quality Assurance
W. S. Lacey, Plant Manager
R. J. Druga, Manager, Technical Services
R. E. Martin, Nuclear Engineering
T. D. Jones, General Manager, Nuclear Operations
H. M. Siegel, Manager, Nuclear Engineering Dept.
N. R. Tonet, General Manager, Nuclear Engr. & Constr. Unit
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector.
Commonwealth of Pennsylvania
bcc w/encls:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o enclosures)
Section Chief, DRP
P. Tam, LPM, NRR
L. Prividy, RI
Rf:
P
F
R
oskoski/meo
ripp
inger
,
9/$86
(
@6g
1
0FFICIAL RECORD COPY
-
.
,
._
,
-
_
.. -_
,.
,
-- -. -_. -
- .
. _ _ - -