Correction of License Amendment Nos. 333 and 311 for Deletion of E-BAR Definition and Revision to Reactor Coolant System Specific Activity Technical Specifications
ML20167A041
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 06/22/2020
From: Marshall M
Plant Licensing Branch 1
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
Marshall M, NRR/DORL/LPLI, 415-2871
References
EPID L- 2019- LLA-0102
Download: ML20167A041 (5)


Text

June 22, 2020 Mr. Bryan C. Hanson Senior Vice President Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

CALVERT CLIFFS NUCLEAR POWER PLANT, UNITS 1 AND 2 - CORRECTION OF LICENSE AMENDMENT NOS. 333 AND 311 FOR DELETION OF E-BAR DEFINITION AND REVISION TO REACTOR COOLANT SYSTEM SPECIFIC ACTIVITY TECHNICAL SPECIFICATIONS (EPID L-2019-LLA-0102)

Dear Mr. Hanson:

By letter dated February 28, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19337D035), the U.S. Nuclear Regulatory Commission issued Amendment No. 333 to Renewed Facility Operating License No. DPR-53 and Amendment No. 311 to Renewed Facility Operating License No. DPR-69 for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2 (Calvert Cliffs), respectively. The amendments were in response to the license amendment request by Exelon Generation Company, LLC dated May 6, 2019 (ADAMS Accession No. ML19127A076). The amendments revised the Calvert Cliffs, Units 1 and 2, Technical Specification (TS) requirements relating to reactor coolant system activity limits.

When these amendments were issued, the abbreviation for microcuries per gram was incorrectly written on replacement TS page 3.4.15-2. The issued replacement page incorrectly abbreviated microcuries per gram as c1/gm. The correct abbreviation is Ci/gm.

The corrected Calvert Cliffs TS page 3.4.15-2 is enclosed. Please remove current page 3.4.15-2 and insert corrected page 3.4.15-2, which is applicable to both Units 1 and 2.

The other TS pages issued as part of Amendment Nos. 333 and 331 were not affected by this error.

If you have any questions, please contact me at (301) 415-2781 or by e-mail to Michael.Marshall@nrc.gov.

Sincerely,

/RA/

Michael L. Marshall, Jr., Senior Project Manager Plant Licensing Branch I Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-317 and 50-318

Enclosure:

Corrected TS page 3.4.15-2 cc: Listserv

ENCLOSURE CALVERT CLIFFS NUCLEAR POWER PLANT, UNITS 1 AND 2 CORRECTED TS PAGE 3.4.15-2

CS Specific Activity 3.4.15 CALVERT CLIFFS - UNIT 1 3.4.15-2 CALVERT CLIFFS - UNIT 2 Amendment No. 333 Amendment No. 311 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME B.

DOSE EQUIVALENT XE-133 > 630 µCi/gm.


NOTE-----------

LCO 3.0.4.c is applicable.

B.1 Restore DOSE EQUIVALENT XE-133 to within limit.

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> C.

Required Action and associated Completion Time of Condition A or B not met.

OR DOSE EQUIVALENT I-131 > 30 µCi/gm.

C.1 Be in MODE 3 AND C.2 Be in MODE 5 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 36 hours SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.15.1 Verify reactor coolant DOSE EQUIVALENT XE-133 specific activity 630 Ci/gm.

In accordance with the Surveillance Frequency Control Program

ML20167A041 OFFICE NRC/NRR/DORL/LPL1/PM

/NRC/NRR/DORL/LPL1/LA NRC/NRR/DORL/LPL1/BC NAME MMarshall LRonewicz JDanna DATE 06/15/2020 06/15/2020 06/22/2020 OFFICE NRC/NRR/DORL/LPL1/PM NAME MMarshall DATE 06/22/2020