I e
e O
APPENDIX B TO FACILITY OPERATING LICENSE NO. NPF COMMONWEALTH EDISON COMPANY BRAIDWOOD STATION UNITS 1 & 2 DOCKET NOS. 50-456 AND 50-457 ENVIRONMENTAL PROTECTION PLAN (NONRADIOLOGICAL)
(
B603100538 860303 PDR ADOCK 05000456 A
~
BRAIDWOOD STATION UNITS 1 and 2 ENVIRONMENTAL PROTECTION PLAN (NON-RADIOLOGICAL)
TABLE OF CONTENTS Section Page 1.0 Objectives of the Environmental Protection Plan.
1-1 2.0 Environmental Protection Issues 2-1 2.1 Aquatic Issues 2-1 2.2 Terrestrial Issues 2-1 3.0 Consistency Requirements 3-1 3.1 Plant Design and Operation.
3-1 3.2 Reporting Related to the NPDES Permit and State Certification 3-2 3.3 Changes Required for Compliance with Other Environmental Regulations 3-3 4.0 Environmental Conditions 4-1 4.1 Unusual or Important Environmental Events 4-1 5.0 Administrative Procedures 5-1 5.1 Review and Audit 5-1 5.2 Records Retention 5-1 5.3 Changes in Environmental Protection Plan.
5-1 5.4 Plant Reporting Requirements 5-2
r l
1.0 Objectives of tire Environmental Protection Plan The Environmental Protection Plan (EPP) is to provide for protection of nonradiological environmental values during operation of the nuclear facility.
The principal objectives of the EPP are as follows:
(1) Verify that the facility is operated in an environnentally acceptable manner, as established by the Final Environmental Statement - Operating License Stage (FES-OL) and other NRC environmental impact assessments.
(2) Coordinate NRC requirements and maintain conststency with other Federal, State and local' requirements for environmental i
protection.
\\
(3) Keep NRC informed of the environmenal effects of facility construction and operation and of-actions taken to control those effects.
I
{
Environmental concerns identified in the FES-OL which relate to water quality matters are regulated by way of the ifcensee's NPDES permit.
t l
l l
l 1-1 1
2.0 Environmental Protection Issues In the FES-OL dated June, 1984, the staff considered the environmental impacts associated with the operation of the two unit Braidwood Station.
No environmental issues were identified which required study or license conditions to recolve environmental concerns and to assure adequate protection of the environment.
2.1 Aquatic Issues No specific aquatic issues were raised by the staff in the FES-OL.
Aquatic matters are addressed by the effluent limitations, monitoring requirements and the Section 316(b) demonstration requirement contained in the effective NPDES permit issued by the Illinois Environmental Protection Agency.
The NRC will rely on this agency for regulation of matters involving water quality and aquatic biota.
2.2 Terrestrial Issues No specific terrestrial issues were raised by the staff in the FES-OL.
2.1
3.0 Consistency Requirements 3.1 Plant Design and Operation The licensee may make changes in stati0n design or operatfor, or perform tests i
or experiments affecting the environment provided such activities do not involve an unreviewed environmental question and do not involve a change in the EPP*.
Changes in station design or operation or performance of tests or experiments which do not affect the enviromnent are not subject to the requirements of this EPP. Activities governed by Section 3.3 are not subject to the requirements of this Section.
\\
Before engaging in additional construction or operational activities which may significantly affect the environment, the licensee shall prepare and record an environmental evaluation of such activity.
Activities are excluded from this requirement if all measurable nonradiological environmental effects are i
i confined to the on-site areas previously disturbed during site preparation and plant construction. When the evaluation indicates that such activity involves an unreviewed environmental question, the licensee shall provide a written evaluation of such activity and obtain prior NRC approval. When such activity involves a change in the EPP, such activity and change to the EPP may be implemented only in accordance with an appropriate license amendment as set forth in Section 5.3 of this EPP.
f a
I This provision does not relieve the licensee of the requirements of 10 CFR 50.59.
3-1
--_.__..-,m__
A proposed change, test or experiment shall be deemed to involve an unreviewed environmental question if f t concerns:
(1) a matter which may result in a l
significant increase in any adverse environmental impact prevfously evaluated in the FES-OL, environmental impact appraisals, or in any decisions of the 4
Atomic Safety and Licensing Board; or (2) a signiffcant change in effluents or power level [in accordance with 10 CFR Part 51.5(b)(2)] or (3) a matter.
l not previously reviewed and evaluated in the documents spectfled in (1) of this Subsection, which may have a significant adverse environmental impact.
i l
The licensee shall maintain records of changes in facility design or operation and of tests and experiments carried out pursuant to this Subsection.
These j
records shall include written evaluations which provide bases for the detemina-i tion that the change, test, or experiment does not involve an unreviewed environmental question or constitute a decrease in the effectiveness of this j
EPP to meet the objectives spectffed in Section 1.0.
The ifcensee shall include as part of the Annual Environmental Operating Report (per Subsection 5.4.1) brief descriptions, analyses, interpretations, and evaluations of such changes, i
tests and experiments.
1 i
j 3.2 Reporting Related to the NPDES Pemit and State Certification i,
Changes to, or renewals of, the NPDES Pemit or the State certification shall j
be reported to the NRC within 30 days following the date the change or renewal 1
is approved.
If a pemit or certification, in part or in its entf rety, is appealed and stayed, the NRC shall be nottfled within 30 days following the date the stay is granted.
l I
3-2
The licensee shall notify the NRC of changes to the effective NPDES Pemit proposed by the licensee by providing NRC with a copy of the proposed change at the same time it is submitted to the pemitting agency.
The licensee shall provide the NRC a copy of the application for renewal of the NPDES Pemit at the same time the application is submitted to the pemitting agency.
3.3 Changes Required for Compliance with Other Environmental Regulations l
Changes in plant design or operation and performance of tests or experiments which are required to achieve compliance with other Federal, State, and local environmental regulations are not subject to the requirements of Section 3.1.
l I
I 3-3 l
_..,.., _. - - - - - - - - ~ -
4.0 Environmental Conditions 4.1 Unusual or Important Environmental Events Any occurrence of an unusual or important event that indicates or could result in significant environmental impact causally related to plant operation shall be recorded and reported to the NRC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> followed by a wrf tten report per Subsection 5.4.2.
The following are examples:
excessive bird impaction events, onsite plant or animal disease outbreaks, mortality or unusual occurrence of any species protected by the Endangered Species Act of 1973, fish kills, increase in nuisance organisms or conditfoes, and unanticipated or emergency discharge of waste water or chemical substances.
No routine monttoring programs are required to implement thf s condition.
I 4-1
5.0 Admfnistrative Procedures 5.1 Review and Audit The Ifeensee shall provide for review and audit of compliance with the EPP.
The audits shall be conducted independently of the individual or groups responsible for performing the specific activity. A description of the organization structure utilized to achieve the independent review and audtt function and results of the audit activitfes shall be maintained and made available for inspection.
5.2 Records Retention Records and logs relative to the environmental aspects of station operation shall be made and retained in a manner convenient for review and inspection.
These records and logs shall be made available to WC on request.
Records of modifications to station structures, systems and components determined to potentially affect the continued protection of the environment shall be retained for the life of the station.
All other records, data and logs relating to this EPP shall be retained for five years or, where appifcable, in accordance with the requirements of other agencies.
5.3 Changes in Environmental Protection Plan I
Requests for changes in the EPP shall include an assessment of the environmental impact of tne proposed change and a supporting justification.
Implemen ta tion 5-1
of such changes in the EPP shall not commence prior to NRC approval of the proposed changes in the form of a license amendment incorporating the appropriate revision to the EPP.
5.4 Plant Reporting Requirements 5.4.1 Routine Reports An Annual Environmental Operating Report describing implementation of this EPP for the previous year shall be submitted to the NRC prior to May 1 of each year.
The initial report shall be submitted prior to May 1 of the year following issuance of the operating license.
The period of the first report shall begin with the date of issuance of the operating license.
5.2
The Annual Environmental Operating Report shall include:
(1)
A list of all changes in station design or operation, tests, and experiments made in accordance with Subsection 3.1 which involved a potentially significant unreviewed environmental question.
(2)
A list of nonroutine reports submitted in accordance with Subsection 5.4.2.
In the event that some results are not available by the report due date, the report shall be submitted noting and explaining the missing results.
The missing results shall be submitted as soon as possible in a supplementary report.
5.4.2 Nonroutine Reports A written report shall be submitted to the NRC within 30 day of occurrence of a noncoutine event.
The report shall (a) describe, analyze, and evaluate the event, including extent and magnitude of the impact, and plant operating 5.3
r characteristics, (b) describe the probable cause of the event, (c) indicate the action taken to correct the reported event, (d) indicate the corrective action taken to preclude repetition of the event and to prevent similar occurrences involving similar components or systems, and (e) indicate the agencies notified and their preliminary responses.
Events reportable under this subsection which also require reports to other Federal, State or local agencies shall be reported in accordance with those reporting requirements in lieu of the requirements of this subsection.
The NRC shall be provided a copy of such report at the same time it is submitted to the other agency.
5.4
---.