i 9

June 20, 1997 Mr. James W. Langenbach j

Vice President and Director, TMl GPU Nuclear Corporation Three Mile Island Nuclear Station P. O. Box 480 Middletown, PA 17057-0191

SUBJECT:

FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) FINAL REPORT OF THE MARCH 5,1997 FULL-PARTICIPATION EXERCISE AT THREE MILE ISLAND NUCLEAR STATION

Dear Mr. Langenbach:

Enclosed is a letter dated May 28,1997, from Ms. Rita A. Calvan, Regional Director for FEMA Region Ill, transmitting the final exercise report for the March 5,1997, full-participation exercise at the Three Mile Island Nuclear Station.

i One deficiency and 25 areas requiring corrective action (ARCAs) were identified during this exercise. The deficiency concerned the timeliness of the first alert and notification sequence by the York County Emergency Operations Center. This deficiency was subsequently remediated later in the exercise when York County successfully activated the alert and notification system to advise the public of a protective action decision.

We request that your staff assist the appropriate offsite officials, where possible, to resolve the identified ARCAs prior to the next full-participation exercise, if this has not already been done.

No response to this letter is required. If you have any questions concerning this matter, please contact me at (610) 337-5198.

Sincerely, f

L/

Michael C. Modes, Chief Emergency Preparedness and Safeguards Branch Division of Reactor Safety t

/y }I-Docket No. 50-289

Enclosure:

FEMA letter dated May 28,1997 and Report 9706300273 970620 poa J

. #1$gg

^oock o5ooo2 '

i Mr. James W. Langenbach 2

cc w/ encl:

E. L. Blake, Shaw, Pittman, Potts and Trowbridge (Legal Counsel for GPUN)

J. C. Fornicola, Director, Licensing and Regulatory Affairs M. J. Ross, Director, Operations and Maintenance D. Smith, PDMS Manager TMI-Alert (TMIA)

J. S. Wetmore, Manager, TMI Regulatory Affairs Commonwealth of Pennsylvania R. A. Calvan, Regional Director, FEMA Region lil Distribution w/enci:

Region I Docket Room (with concurrences)

Nuclear Safety Information Center (NSIC)

PUBLIC NRC Resident Inspector T. Kenny, DRS P. Eselgroth, DRP D. Haverkamp, DRP C. O'Danielt, DRP D. Screnci, PAO Distribution w/enci (VIA E-MAIL):

W. Dean, OEDO P. Milano, NRR, PDI-3 B. Buckley, PM, NRR, PDI-3 L. Thonus, NRR S. Weiss, NRR R. Correia, NRR F. Talbot, NRR Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME: G:\\EP&SB\\LAUGHLIN\\TMIFEMA.620 To r.c.iv.. copy of thi. docum.nt, indic.t. in th. nox: c - gopyAthout pttachment/enclosur.

  • E' = Copy with attachment / enclosure "N" = No copy OFFICE Rl/ ORS g) l Bl/ ORS ffl/

l l

l l

NAME FJLaughhn Q g MModes l j DATE 06/20/97 OtW/g)9 /

/,

06/ 197 06/ /97 06/ /97 OFFICIAL RECORD COPY