March 10,1997

'Mr. Roy A.~ Anderson Senior Vice President, Nuclear Operations Florida Power Corporation ATTN: Manager, Nuclear Licensing (SA2A)

Crystal River Energy Complex 15760 W Power Line Street l

Crystal River, Florida 34428-6708 i

SUBJECT:

CRYSTAL RIVER NUCLEAR GENERATING PLANT UNIT 3 10 CFR 50 APPENDIX R DESIGN BASIS FOR REMOTE SHUTDOWN l

Dear Mr. Anderson:

In a letter dated August 15, 1994, relat'ing to Generic Letter 87-02, you j

described the methodology for achieving and maintaining hot shutdown following i

a design basis seismic event.

In Attachment 2, page 2, you stated that

"...given a loss of off-site power, it is not possible to cool down to a hot shutdown condition within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> even without additional failures. An additional 52 hours6.018519e-4 days <br />0.0144 hours <br />8.597884e-5 weeks <br />1.9786e-5 months <br /> would be needed to cool down to the Decay Heat System i

entry point (280*F T,,the atmospheric dump valves."This is because of the limited cap relievesteamthrougb).

e Final Safety Analysis Report, paragraph 7.4.6, Auxiliary Control Stations i.

(Remote Shutdown System) indicates that the design basis for the remote shutdown system is 10 CFR Part 50, Appendix R, Section L and 10 CFR Part 50, Appendix A, Criterion 19. Appendix R, Section L 1(d), requires alternate shutdown capability to "... achieve cold shutdown within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />...."

The discussion in your August 15, 1994, letter would appear to imply that you cannot meet the requirements of Appendix R, Section L 1(d).

I Please confirm that you can meet your design basis for Appendix R requirements for alternate shutdown capability. We request your response within 30 days of receipt of this letter.. If you have any questions regarding this matter please contact me at (301) 415-1471 or write to me.

Sincerely, Original signed by g%

gtggy L. Raghavan, Project Manager uun a Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

(

D Docket No. 50-302 cc: See next page Distributioni:DahketFile;. Public CR3 R/F S. Collins F. Miraglia A Thadani R.-Zimmerman S. Varga J. Zwolinski OGC ACRS J. Jaudon, R-II Gtracy DOCUMENT NAME:

G:\\ CRYSTAL \\TSB374.USQ

-To receive a copy of this document, indicate in the box:

"C" - Copy without attachment / enclosure "E" - Copy with attachment / enclosure "N" - No copy f.3 0FFICE P0ll 3/PM l

PDil 3/LA _

A l C' APLB

/% C l PDil 3/D,}

lC l

NAME LReghaven W BClayton NW lI FMobdon N DATE

% /3./97 _ _

h / G /97 7/7 /97 "I /sfV97 97031N2b3970310 ICIAL RE M M 1*J* Y " $"

^ '

~~

1 Mr. Roy A. Anderson CRYSTAL RIVER UNIT N0. 3 g.Flo;ida Power Corporation SENERATING PLANT I

cc:

Mr. R. Alexander Glenn Senior Resident Inspector Corporate Counsel Crystal River Unit 3 Florida Pcwer Corporation U.S. Nuclear Regulatory Comission

)

MAC-A5A 6745 N. Tallahassee Rwi P.O. Box 14042 Crystal River, Florida 34428 St. Petersburg, Florida 33733-4042 i

Mr. John P. Cowan i

Mr. Bruce J. Hickle, Director Vice President, Nuclear Production j

Nuclear Plant Operations (NA2C)

(SA2C)

Florida Power Corporation Florida Power Corporation Crystal River Energy Complex Crystal River Energy Complex i

15760 W. Power Line Street 15760 W. Power Line Street l

Crystal River, Flortda 34428-6708 Crystal River, Florida 34428-6708 1'

Mr. Robert B. Borsum Regional Administrator, Region II B&W Nuclear Technologies U.S. Nuclear Regulatory Comission 1700 Rockville Pii;, Suite 525 101 Marietta Street N.W., Suite 2900 5

Rockville, Maryland 20852 Atlanta, Georgia 30323 Mr. Bill Passetti Mr. Kerry Landis Office of Radiation Control U.S. Nuclear Regulatory Comission Department of Health and 101 Marietta Street, N.W. Suite 2900 l

Rehabilitative Services Atlanta, Georgia 30323-0199 1317 Winewood Blvd.

Tallahassee, Florida 32399-0700 Attorney General i

Department of Legal Affairs J

The Capitol i

Tallahasse.e, Florida 32304 Mr. Joe Myers, Director Division of Emergency Preparedness Department of Comunity Affairs 2740 Centervier Drive Tallahassee, Florida 32399-2100 Chairman l

Board of County Comissioners Citrus County 110 North Apopka Avenue Iverness, Florida 34450-4245 Mr. David Kunsemiller, Director Nuclear Operations Site Support (SA2A)

Florida Power Corporation Crystal River Energy Complex 15760 W. Power Line Street Crystal River, Florida 34428-6708