TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 1630 Chestnut Street Tower II July 9, 1985 BLRD-50-438/84-57 BLRD-50-439/84-53 U.S. Nuclear Regulatory Commission Region II Attn:' Dr.'J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323
Dear Dr. Grace:
BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - INCORRECT RESPONSE SPECTRA M ANALYSIS OF REACTOR BUILDING SPRAY PIPING - BLRD-50-438/84-57 AND' c--
BLRD-50-439/84 SECOND INTERIM REPORT S
The subject deficiency was initially reported to NRC-0IE Inspector S. Weise on November 8,1984 in accordance with 10 CFR 50.55(e) as y
NCR BLN CEB 8417. This was followed by our first interim report dat e December 7, 1984. Below is our second interim report. We expect to**
submit our next report on or about February 14, 1986, c.rs c2 Interim Proaress TVA has generated the correct seismic response spectra for el 890.2' of the containment structure dome and has completed the reanalysis of the NS system piping. The affected piping supports are being requalified using the new analysis data. The corrected seismic response spectra will be included in a revision to the BLN seismic analysis report.
If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.
Very truly yours, TENNESSEE VALLEY AUTHORITY
.d &*m
.J. W. Hufham, Manager Licensing and Risk Protection ec: