/ iWERAGE DAILY UNIT POWER LEVEL Docket No.
50-311 0,
Unit Name Salem # 2 Date March 10, 1984
,, Completed by L. K. Miller Telephone 609-935-6000 Extension 4455 Month February 1984 Day Average Daily Power Level Day Average Daily Power Level (MVe-NET)
(MWe-NET) 1 0
17 0
2 0
18 0
3 0
19 0
4 0
20 0
5 0
21 0
6 0
22 0
l 7
0 23 0
8 0
24 0
l 9
0 25 0
10 0
26 0
11 0
27 0
12 0
28 0
13 0
29 0
14 0
30 15 0
31 16 0
)
Pg. 8,1-7 R1 O
Page 2 of 8 8403220142 840229 POR ADOCK 05000311 R
OPERATING DATA REPORT Docket No.
50-311 f^'
Date March 10, 1984
(
Telephone 935-6000 Completed by L. K. Miller Extension 4455 Operating Status 1.
Unit Name Salem No. 2 Notes 2.
Reporting Period February 1984 i
3.
Licensed Thermal Power (MWt) 3411 l
4.
Nameplate Rating (Gross MWe)
YTTY 5.
Design Electrical Rating (Net MWe)
TTTE 6.
Maximum Dependable Capacity (Gross MWe) ll49 7.
Maximum Dependable Capacity (Net MWe) 1106 8.
If Changes Occur in Capacity Ratings (items 3 through 7) since Last i
Report, Give Reason N/A 9.
Power Level to Which Restricted, if any (Net MWe)
N/A
- 10. Reasons for Restrictions, if any N/A This Month Year to Date Cumulative
- 11. Hours in Reporting Period 696 1440 20906
- 12. No. of Hrs. Reactor was Critical 18.7 18.7 11727.2
- 13. Reactor Reserve Shutdown Hrs.
677.4 1421.4 2768
,_s
(\\ >j 14 Ecurs Generator On-Line 0
0 11417.3
- 15. Unit Reserve Shutdown Hours 0
0 0
- 16. Gross Thermal Energy Generated (MWH) 4879 4879 33475951
- 17. Gross Elec. Energy Generated (MWH) 0 0
10868290
- 19. Unit Service Factor
_ (13922T~-'
(18698) 1G298550
- 18. Net Elec. Eneroy Generated
(. WH)
M 0
0 54.6
~
- 20. Unit Availability Factor 0
0 54.6
- 21. Unit Capacity Factor (using MDC Net) 0 0
44.5
- 22. Unit Capacity Factor (using DER Net) 0 0
44.2 j
- 23. Unit Forced Outage Rate 100 100 34.0 l
- 24. Shutdowns scheduled over next 6 months (type, date and duration of each) l N/A
- 25. If shu*:down at end of Report Period, Estimated Date of Startup:
N/A
- 26. Units in Test Status (Prior to Commercial Operation):
Forecast Achieved Initial Criticality 6/30/80 8/2/80 Initial Electricity 9/1/80 6/3/81
(3 Commercial Operation 9/24/80 10/13/81 i
(,) 8-1-7. R2 Page 3 of 8 L
F
(,,-
\\
s _
UNIT SHUTDOWM A
,20WER REDUCTIONS Docket No. 50-3 REPORT MONTH Feb$uary 1984 Unit Name Sn em
.4 Date March 10, 1984 Completed by L.K. Miller Ttlephone 609-935-6000 Extension 4455 Method of Duration Shutting License Cause and Corrective No.
Date Type Hours Reason Down Event System Component Action to 1
2 Reactor Report Code 4 Code 5 Prevent Recurrence Statcr Core 84-010 01-01 F
696 A
4 HA GENERA Iron Generator 3 Method 4 Exhibit G 5 Exhibit 1 1
2 Reason F: Forced A-Equipment Failure-explain 1-Manual
-nstructions Salem as S: Scheduled B-Maintenance or Test 2-Manual Scram.
for Prepara-Source C-Refueling 3-Automatic Scram, tion of Data D-Regulatory Restriction 4-Continuation of Entry Sheets E-Operator Training & Licensing Exam Previous Outage for Licensee F-Administrative 5-Load Reduction Event Report G-Operational Error-explain 9-Other (LER) File H-Other-explain (NUREG 0161)
Page 4 of 8
NDW N
1 MAJOR PLANT MODIFICATIO!:S UNIT N AME:
SALEM 2
'REPONT MONTH FEBRUARY 1984 DATE:
MARCH 10, 1984 COMPLETED BY :
L.
K. MILLER
/^
TELEPHONE.
(609) 339-4455 l
b}
- DCR NO-PRINCIPLE SYSTEM SU3 JECT l
l
.2EC-0807 Containment Purge Add support to control air lines (tubing) supply to isolation valves 2VC1 and 2VC5.
2EC-1283 Fuel liandling Building This change adds a diode across Ventilation the coils of solenoid valves SV-779 and SV-780.
2EC-1547 Electrical Connect directly to the station ground the housing of 25kV isolated phase bus.
2SC-0364 Condensate Modify 23A Circulator Water Pump Motor to allow filling of oil reservoirs.
fx/
s l.
4 l
l
\\
(
4 I
\\_/
- DESIGN CHANC-E REGUEST Page 5 of 8 i-1-7.R1
MAJOR PLANT MODIFICATIONS DOCKET NO.:
50-311 REPORT MONTH FEBRUARY 1984 UNIT NAME: Salem 2 DATE:
March 10, 1984 COMPLETED BY:
L.K. Miller TELEPHONE:
609/339-4455 DCR NO.
10CFR 50.59 SAFETY EVALUATION 2EC-0807 This change is safety related and affects safety related equipment.
No unreviewed safety or environmental questions are involved.
2EC-1283 This change only for the original design to function as intended by preventing reverse flow through the solenoid coils.
No unreviewed safety or environmental questions are involved.
2EC-1547 Implementation of this DCR will not create any new safet}
hazards.
No unreviewed safety or environmental questions are involved.
(
2SC-0364 Implementation of this DCR will affect the operation of the motors and does not involve any change to the FSAR or Technical Specifications.
No unreviewed safety or environmental questions are involved.
- DCR - Design Change Request Page 6 of 8 L
SALEM UNIT 2 OPERATIONS
SUMMARY
REPORT FEBRUARY 1984 Unit No. 2 began the month in cold shutdown as reassembly of the generator continued.
Major items accomplished durief the month included:
installation of the generator exciter; assembly of the blower housing; performance of a bearing oil flush; and alignment checks of the generator couplings and bearings.
Additionally, all hydrogen seal housing bolts and Bellville washers were replaced.
Other work during this period included reassembly of No. 23 Containment Fan Coil Unit, and replacement of No. 21 Containment Sump Pump.
Unit No. 2 entered Mode 3 on February 4, however, the discovery l
of leaking Safety Injection System check valves caused the unit to be cooled down on February 7.
An oil seal Inak was discovered on the turbine thrust bearing and required disassembly and refurbishment of l
the bearing parts.
Following the replacement of the four SJ143 check valves and inspection of the four SJ56 check valves, the unit was returned to Mode 3 on February 17, at 1737 hours0.0201 days <br />0.483 hours <br />0.00287 weeks <br />6.609285e-4 months <br />.
Later, at 1757 hours0.0203 days <br />0.488 hours <br />0.00291 weeks <br />6.685385e-4 months <br />, an Unusual Event was declared when Steam Generator Safety Valve 22MC14 prematurely lif ted and would not reseat until pressure was decreased.
A lift check was performed on all steam generator safety valves prior to cooling down on February 19, to investigate and repair leakage past Steam Generator Safety Valves 22MS11, 22MS13, and 22MS14.
[]s The valves were repaired and a unit heatup was commenced on February 21, 1984.
A reactor startup was performed, with criticality being achieved on February 24, at the completion of generator reassembly.
Post maintenance non-synchronized operational testing started the same day.
The reactor was then taken.,uberitical and steam generator safety valve lift checks were performed.
During the pre-synchronization test period, it was determined that a hydrogen leak into the stator water cooling system existed.
Investigation revealed the stator water nipple for Coil Bil, turbine end, was l
le3 king.
The nipple was replaced, rebrazed, and tested satisfactorily.
O Page 7 of G
REFUELING INFORMATION O
DOCKET NO.:
50-311 I
COMPLETED BY L.K. Miller UNIT NAME:
Salem 2 DATE:
March 10, 1984 TELEPHONE:
609/935-6000 l
EXTENSION:
4455 P
Month February 1984 1.
Refueling information has changed from last month:
YES NO X
2.
Scheduled date for next refueling:
January 5, 1985 3.
Scheduled date for restart following refueling:
March 17, 1985 i
4.
A)
Will Technical Specification changes or other license j
amendments be required?
YES NO 3
NOT DETERMINED TO DATE 3/1/84 l
i B)
Has the reload fuel design been reviewed by the Station Operating Review Committee?
YES NO X
If no, when is it scheduled? November 1984 O
5.
Scheduled date (s) for subnitting proposed licensing action:
December 1984 (if required) l 6.
Important licensing considerations associated with refueling:
~
NONE a
)
e-7.
Number of Fuel Assemblies:
A)
Incore 193 B)
In 3 pent Fuel Storage 72 i
8.
Present licensed spent fuel storage capacity:
1170 Future spent fuel storage capacity:
1170 9.
Date of last refueling that can be discharged to spent fuel pool assuming the present licensed capacity:
March 2000 8-1-7.R4 l
l 1
LO Page 8 of 8
.~.
O FSI4G Put.!n. S"r vu e f R tr u; and Gn Compen P O. Box E Hanurks BwiTt, New J"rwy 08038 Liem Generating Station March 10, 1984 Director, Of fice of Inspection and Enforcement U.S.
Nuclear Regulatory Commission Washington, DC 20555 Dea r Sir:
MONTI!LY OPERATING REPORT SALEM NO. 2 DOCKET NO. 50-311 In Compliance with Section 6.9, Reporting Requirements for the Sclem Technical Specifications, 10 copies of the following monthly operating reports for the month of February 1984 are being sent to you.
Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Major Plant Modification Operating Summary Refueling Information Sincerely yours,
Mi
(
J.
1.
uoko, Jr.
General Manager - Salem Operations LKM:sbh cc:
Dr. Thomas E.
Murley Regional Administrator USNRC Region I 631 Park Avenue King of Prussia, PA 19406 Director, Office of Management Information and Program Control U.S.
Nuclear Regulatory Commission Washington, DC 20555 Enclosures Page l of 8 8-1-7.R4 fh.