Amends 162 & 142 to Licenses DPR-53 & DPR-69,respectively, Deleting Designation of PORVs as Category C Valves for ASME Code,Section XI Re Inservice Testing Program Requirements
ML20079M680
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 10/21/1991
From: Capra R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20079M683 List:
References
NUDOCS 9111080332
Download: ML20079M680 (7)


Text

_

pS RSCu

+8 UNITED STATES l'

NUCLE AR REGULATORY COMMISSION

, "r,c i

WASHING 1ON. D. C. 70%5

/

g-p PALTIMORE GAS Atl0 ELECTRIC COMPAtlY DOCKET NO,. 50-317 CALVERT C,LJff,5, t4UCLE AR, POWER, PL At!T,,U!!JT, Np,,1

.AEE90.[!I.T,,Tp, f,A,CJ,LJ,TL 0f,E,R A,TJ !!G L I CE NSE Amendment tio.162 License No. OPR-53 1.

The fluclear Reculatory Ccmmission (the Commission) has found that:

A.

The application for amendment by Baltimore Gas and Electric Company (the licensee) dated August 27, 1991, complies with the standards anti requirements of the Atomic Energy Act of 1954, as amcnded (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; D.

The facility will operste in conformity with the aoplication, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be ccnducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

'The issuance of this amendnent is in accordance with 10 CFR Part 51 of the Corrmission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(?) of Facility Operating License No. DPR-53 is hereby amended to read as follows:

l 9111080332 911021 l

PDR ADOCK 05000317 P

PDR

t 2

(2) -T,e,chnical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment flo. 162, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance and

ill be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISS10tl RM O CW Robert A. Capra, Director Project Directorate I-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: October 21, 1991 e

i

__________._m_

o

  1. sk# AI Gg

^

o UNITE D STATES

[

M

!\\jm h

NUCLE AR REGU'.ATORY COMMISSION t

W ASHING TON. D. C. 20%b f

BALTII40,F;E GAS AfD, ELE,0T,R,1C, COEPA!Q US.C,K,E,T, !1,0,8!0-318 C ALVE RT CL IF FS hUCLE AR POWER PLAtiT,, ti!ll,T,!10,.,,P AtoEt Dt1ENT 10 FACllllY OPERATitlG LICENSE Amendment flo,142 License No. DPR-69 1.

The f:uclear Regulatory Cc "ocnuission) has found that:

A.

The application for amc more Gas and Electric Company (the licensee) dated Aur niles with the standards and requirements of the Atot 354, as amended (the Act) and the Commission's rules

'et forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Connission's regulations; D.

The issuance of this amendnent will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specificationi as indicated in the attachment to this license amendment, and paragraph 2.C.? of Facility Operating License No, DPR-69 is hereby amended to read as follows:

4

L l

2 (2) Technical, Spec,ifications The Technical Specifications contained in Appendices A and B, as revised through Araendment No.142, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.

FOR THE Nt! CLEAR REGULATORY COMMIS$10H A

U 0' V

Robert A. Capra, Director Project Directorate 1-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specificatiens Date of Issuance: October 21, 1991 I

9 4

ATTACHMENT TO LICENSE AMENDMENTS

.A.M.E.N.0.M.E.N.T..N.O 16"...F.A.C.I.L.I.T.Y..O.P.E.R.A.T.I.N.G..L.I.C.E.ll.S.E N0. OP R-5 3

...~r Af tEllDMEt4T Hp,., J,4,2,, f,A,C),LJ,T,Y, p,P,E,R A,T I N G, !.J,C E N,5,E, Np,,, p,P,R,,El

.D.O.C.K.E.T..N.O.S 5.0..317. A.N.D. 5. 0..318 Revise Appendix A_as follows:

1 Remove P,ag,e,s, insert _Pages 3/44-26c(DPR-53) 3/4 4-26c DPR-53) 3/4 4-27c (DPR-69) 3/4 4-27c DPR-69) 1

-~. - - -

4 1

REACTOR COOLANT SYSTEM-i

.+

SURVEllLANCE RLQUIREMENTS 4.4.9.3.1 Each PORV shall be demonstrated OPERABLE by:

__ a.

Performance of a CliANNEL FUNCTIONAL TEST on the PORV actuation -

channel,- but excluding valve operation, within 31 days prior to entering a condition in which the PORV is required OPERABLE and at least once per 31 days thereafter when the PORY is required OPERABLE.

b.

Performance n'

liANNEL CAllBRATION on the PORV actuation channel at li:aet unce per 18 months.

c.-

Verifying the PORV isolation valve is open at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when the PORV is being used for overpressure protection, d.

Testing in accordance with the inservice test requirements pursuant to Specification 4.0.5.

4.4.9.3.2 The RCS vent (s) shall be verified to be open at least once per

-12 hours

  • when the vent (s) is being used for overpressure protection.

4.4.9.3.3 All high pressure safety injection pumps, except the above

- 0PERABLE pump, shall be demonstrated inoperable at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that the mo'ar circuit breakers have been removed from their electrical power supply circuits or by verifying their discharge valves are locked shut. The automatic opening feature of the high pressure safety injection loop MOVs shall be verified disabled at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, Except when the vent pathway is locked, sealed, or otherwise secured in the open position, then verify these vent pathways open at least once per 31 days, p

CALVERT_ CLIFFS

_ UNIT 1 3/4 4-26c Amendment No. Jffi/E,162

y REACTOR: COOLANT SYSTEM SJRVEILLANCE RE0QlREJENTS 4.4.9.3.1 Each PORV shall be demonstrated OPERABLE by:

a.

Performance of a CHANNEL FUNCTIONAL TEST on the PORV actustion I

channel, but excluding valve operation, within 31 days prior to entering a condition in which the PORV is required OPERABLE and at least once per 31 days thereafter when the PORV is required OPERABLE.

b.

Performance of a CilANNEL CALIBRATION on the PORV actuation channel at least once per 18 months, c.

Verifying the PORV isolation valve is open at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when the PORV is being used for overpressure protection, d.

Testing in accordance with the inservice test requirements pursuant to Specification 4.0.5.

4.4.9.3.2 The RCS vent (s) shall be verified to be open at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

  • when the vent (s) is being used for overpressure protection.

4.4.9.3.3 All high pressure safety injection pumps, except the above OPERABLE pump, shall be demonstrated inoperable at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that the motor circuit breakers have been removed from their electrical power supply circuits or by verifying their discharge valves _are locked _ shut.

The automatic opening feature of the high

- pressure safety injection loop MOVs shall be verified disabled at least once-per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

i Except when the vent pathway is locked, sealed, or otherwise secured in the open position, then verify these vent pathways open i.L least once per-31 days.

l CALVERT CLIFFS - UNIT 2 3/4 4-27c Amendment No. /E# 11, 142 L

,.