Interim Deficiency Rept,Item S-12 Re Bergen-Paterson EA-3 Pipe Clamp Incorrectly Used in Support Design.Initially Reported on 830620.Design or Installation Tolerances Will Be Revised to within 6-degree Allowable Skew Angle
ML20077D541
Person / Time
Site: Zimmer
Issue date: 07/18/1983
From: Williams J
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, LOZ-83-0087, LOZ-83-87, NUDOCS 8307260556
Download: ML20077D541 (2)


Text

-

hk 1"

[

gf k

THE CINCINNATI GAS & ELECTRIC COMPANY W

CINCINN ATI, OHIO 45201 July 18, 1983 LOZ-83-0087 J. WILLI AMS, J R j

SENIOR VICE MES4 DENT NuctE*n onnam3NS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention:

Mr. J.G. Keppler Regional Administrator Gentlemen:

RE:

WM. H.

ZIMMER NUCLEAR POWER STATION - UNIT 1 10CFR50. 55 (e), ITEM S BERGEN-PATTERSON EA-3 PIPE CLAMP INCORRECTLY USED IN SUPPORT DESIGN W.O.

57300, JOB E-5590, FILE NO. 956C, S-12 This letter constitutes an interim report concerning the subject condition initially reported to the Commission on June 20, 1983 as a potentially reportable deficiency under the requirements of 10CFR50.55 (e).

The deficiency was identified as a result of a 10CFR Part 21 evaluation reported by Bergen-Patterson Pipe Support Corporation concerning misapplication of their standard "EA-3" pipe clamp.

Bergen-Patterson Catalog #66 did not specify at what angle or rotation the EA-3 clamp attachment could be installed for clamps having an off-axis load direction.

Bergen-Patterson has since specified a 6 degree skew angle.

A review of all Zimmer safety-related pipe-support drawings identified fifteen clamps having an off-axis load direction.

As such, the misapplication of the clamps could potentially affect the safe operation of the facility.

The systems that may be affected are:

Main Steam (ftS) ;

Reactor Water Clean-up (RT); and Reactor Building Closed Cooling Water (WR).

As a result of this review CG&E has determined the item to be reportable under 10CFR50.55 (e).

In lieu of extensive analysis and/or testing to determine if the clamps could perform their intended function as designed, the design and/or installation tolerances will be revised such that the final installation would be within the manufacturer's 6 degree allowable skew angle.

Failing this, an alternate clamp will be specified.

Mb 8307260556 830718

{DRADOCK05000 iin

f Mr. J.G. Keppler Regional Administrator July:18, 1983 LOZ-83-0087 Page.2 The resolution of the corrective action for.the fifteen EA-3 pipe clamps identified as having an off axis load direction is summarized as'follows:

3 supports have skew angles within~the 6 degree ~ allowable as designed; 6 require revised installation tolerances;'5 require revised designs; and 1 requires an alternate clamp to be specified.

All revised support drawings will be issued,by July 15, 1983 and a follow-up report will be submitted by August 25, 1983.

We trust the above will be found acceptable as an interim report under 10CFR50.55 (e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY h

4 $n _ - - /

By WILLIAMS, JR.

ENIOR VICE PRESID T

DJS/JAN/sfr cc:

NRC Office of Inspection & Enforcement j

l Washington, D.C.

20555 NRC Senior Resident Inspector ATTN:

W.F. Christianson NRC Zimmer Project Inspector, Region III ATTN:

E. R. Schweibinz i

i I

l ll-i-

4

,--_e

,m-,

en-+--

e

,,,-e-,_,

v7

-q w, p-em w

w-

-wwee--

-e m--

,s,-,,,

,,