Clarifies Statement in NRC 891207 SER Re Compliance W/Atws Rule (10CFR50.62) on safety-related 1E Power Supplies
ML20073B930
Person / Time
Site: Crane Constellation icon.png
Issue date: 04/20/1991
From: Broughton T
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
C311-91-2034, TAC-59151, NUDOCS 9104250009
Download: ML20073B930 (3)


Text

..

GPU Nuclear Corporation

. Nuclear

=orsweo Middletown, Per nsylvania 17057 0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number; (717) 948-8005 April 20, 1991 C311-91-2034 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Gentlemen:

Subject:

Three Mile Island Nuclear Station, Unit No.1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Safety Evaluation for Compliance with 10 CFR 50.62 Anticipated Transient Without Scram (ATW3) (TAC No. 59151)

By letter dated December 7,1989, the Staff transmitted the subject Safety Evaluation Report (SER) by the Office of Nuclear Reactor Regulation (NRR) to GPU Nuclear (GPUN) Corporation. This letter serves to clarify one statement in the SER with regard to item No. 6 " Safety Related (IE) Power Supplies" (Page 6, at top), namely:

"The licensee stated that the AMSAC (HSPS and EHC/ETS) equipment and the RCS pressure signal loops for the DSS are powered by safety related (1E) power supplies (e.g., RTS vital buses) as approved in Reference 6 and discussed under item 2."

Reference 6 of the SER is "NRC Letter, G. Holahan to L. C. Stalter (BWOG),

' August 17, 1988 B&W/NRC ATWS Meeting,' September 7, 1988." Reference 6, Option 2, allows the use of shared vital power supply sources for the ATWS Mitigation System Actuation Circuitry (AMSAC) functions and Reactor Trip System (RTS) if a Failure Modes and Effects Analysis (FMEA) shows that common mode failures will not propagate through power supplies and disable the RTS.

In this case, AMSAC must also be a Class 1E system. The SER reference to Reference 6 implies that the TMI-1 AMSAC is entirely Class 1E which is not the case.

As indicated in our submittal of October 4,1989 (GPUN Letter No. C311-89-2058),

the AMSAC functions, namely:

Emergency Feedwater (EFW) initiation and turbine trip are performed by the Heat Sink Protection System (HSPS) and Electro-

/

Hydraulic Control / Emergency Trip System (EHC/ETS), respectively.

Figure 7 of that submittal depicts the ATWS power sources to these two (2) systems, and is attached for ease of reference.

9104250009 91042f)

PDR ADOCK G500 2 9 bE UVUV GPU Nuclear Corporation is a subsidiary of General Pubhc Utihties Corporation

()

Document Control Desk C311-91-2034 Page 2 HSPS is a Class 1E system and powered from a Class IE supply. The EHC/ETS is not a Class 1E system, is not powered from a Class 1E supply, and is powered from an independent Permanent Magnet Generator (PMG), as shown on Figure 7, to meet the AMSAC power supply requirements. The only potential interf ace between the EHC/ETS system and the RTS is-through a non-1E inverter that is fed backup power from a Class 1E station battery. Our submittal of October 4,1989 provided a FMEA for this potential interface and determined that a fault on the EHC/ETS system will not propagate through this source so as to disable AMSAC or the RTS, This clarification has been discussed with the NRR Project Manager.

Sincerely, IL T. G. Broy hton Vice President and Director, TM1-1 GMG/plp cc:

Administrator, Region 1 TM1-1 NRC Project Manager Senior NRC Resident inspector i

A KWS 30WER SOURCES (FIGURE 7 )

lA ESMCC IBES MCC

-STATION 1 BAllERY l TRB 9

9 120VAC DIST PNL (BOP)

]

I VITAL BUSSES A

C D

B O#

I NV. l E p

it l '

F RPS RPS RPS RPS 1

q p

p p

p 120vAC I

CH C il CH CH I

((g SyA[T M

L DSS LOGIC

?

l 3

4 2

I o

I l

l AMSAC /HSPS PRIMARY PRIMARY,

I Ps 6 U]r U

)5 t

i l

e u

?

TRAIN TRAIN

'm i

A B

i 120VAC DIST PNL (BOP) t_____------------

J u

BACKUP,

BACKUP -- '

~

i

.