4 PHILADELF'HIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 OOI'IOOI PHILADELPHIA. PA.19:01 JOHN S. MEMPER
.. = :: = : 1 -
MAR 211983 Docket Nos. 50- 352 50-353 Mr. A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing U. S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
Request for Additional Information Regarding Audits by NRC Seismic and Dynamic Qualification Review Team (SQRT) and Pump and Valve Operability Review Team (PVORT)
References:
- 1) Letter, A. Schwencer to E. G. Bauer, Jr.,
dated July 30, 1982
- 2) Letter, J. S. Kemper to A. Schwencer, dated January 3, 1983
Dear Mr. Schwencer:
l We are pleased to provide updated information regarding current test programs as stated in the Reference 2 letter. Attached is a listing of equipment and information relative to location, dates, and a brief description of test programs. We will provide updated information as it becomes available or as items are added'to the list.
l Should any additional information be required, please do 'not hesitate to contact us.
1 Very truly yours, ebS&f f
Attachment Copy to:
See attached service list.
M 8303290479 830321 i
. m.-
w I
~
Limerick Generating Station Dynamic Qualification Test Program List Equipment Vendor Test Lab Test Date Test Location Program Description Pressure Switches Mercoid Wyle 3/1/83 Huntsville, Alabama Random multi-frequency, simultaneous tri-axial shaker table tests _(5,OBE and 1_ SSE) with resonance search over a' frequency range of one to 100 Hertz for each of four different models In-Line Elect.
Veam Div.
N.T.S.*
Start Hartwood, Virginia Environmental and Dynamic Testing-Plug Connectors of Litten
" aging" Dynamic program is RIM shake 2/15/83-table tests, resonance search Dynamic 1-100 Hz each axis for each of Testing three models Later Air Operated Velan Valves N.T.S.*
2/15/83 Saugus, California Dynamic RIM type shake table test Valves (w/Invar/
Start per IEEE 382-80 of air actuators Killey &
Fixture and static deflection tests of Mueller Fabrication-air actuator / valve assemblies Actuators)
Actual Shake Rockwell Test to Valves (w/
Follow Fisher Actuator)
Anchor Darling (w/ Miller)
National Technical Systems
_,___-m i' + apr
-l
. i
- ~
Equipment
-Vendor Test Lab Test Date Test Location Program Description.
(S) Start-(C) complete RRCS Panels GE GE (S)-4/18/83 GE-San Jose, CA Biaxial shake table RRS testing (C) 6/24/83 Resonance search 1-100Hz.
Extended duration: tests-MDR Relay Potter-CE (S) 5/2/83 GE-San-Jose, CA Biaxial shake table RRSLtesting Brumfield (C) 5/27/83 Resonance search 1-100Hz Extended duration tests Power Supply GE GE (S) 2/21/83 GE-San Jose, CA Biaxial shake table RRS testing
'(C) 4/1/83 Resonance search 1-100Hz Extended. duration tests-e CR'2940 Switch GE GE (S) 3/14/83 GE-San Jose, CA Biaxial shake table RRS testing (C) 4/22/83 Resonance search 1-100Hz.
Extended duration tests Switch Cutler-GE (S) 3/7/83 GE-San Jose, CA Biaxial shake table RRS testing Hammer (C) 4/8/83 Resonance search 1-100Hz Extended duration tests Power Range GE GE (S) 3/1/83 GE-San Jose, CA Miaxial shake table RRS' testing Monitoring Panel (C) 3/15/83 uesonance search 1-100Rz Extended duration tests Level Transmitter Gould NTS (S) 5/4/83 Saugus, CA Biaxial' shake table RRS' testing-(C) 7/15/83 Resonance search 1-100Hz Extended duration tests Level Switch Magnetrol Acton (S) 3/7/83 Acton, MASS Seismic Recheck Labs (C) 3/14/83 t
r Service List Copy to: Judge Lawrence Brenner Judge Richard F. Cole Judge Peter A.' Morris Troy B. Conner,-Jr.,'Esq.
Ann P. bodgdon Mr. Frank R. Romano Mr. Robert L. Anthony Mr. Marvin I. Lewis Judith A. Dorsey, Esq.
Charles W. Elliott, Esq.
Mr. Alan J. Nogee Robert W. Adler, Esq.
Mr. Thomas Gerusky Director, PA Emergency Management. Agency Mr. Steven P. Hershey James M. Neill, Esq.
Donald S. Bronstein, Esq.
Mr. Joseph H. White, III Dr. Judith H. Johnsrud Walter W. Cohen, Esq.
Robert J. Sugarman, Esq.
Rodney D. Johnson Atomic Safety and Licensing Atomic Safety and Licensing Appeal Board Board Panel Docket and Service Section i
l i
4
,om e,--,e
-m
-,, -. ~, -, -, -, - - - - -, - - -