ML20056H150

From kanterella
Jump to navigation Jump to search
Approves 930715 Affidavit Requesting Withholding of Jul 1993, Statistical Analysis of Small Break LOCA Upper Bound PCT for Peach Bottom 2/3, Per 10CFR2.790
ML20056H150
Person / Time
Site: Peach Bottom  Constellation icon.png
Issue date: 08/23/1993
From: James Shea
Office of Nuclear Reactor Regulation
To: Klapproth J
GENERAL ELECTRIC CO.
References
NUDOCS 9309080302
Download: ML20056H150 (4)


Text

..

fr Ji

/

! ' Ib' k

UNITED STATES f

f NUCLEAR REGULATORY COMMISSION l

"g s

,/

WASHINGTON, D.C. 2055A001 August 23, 1993 j

l Docket Nos. 50-277 and 50-278 Mr. James F. Klapproth Manager-Fuel Licensing

{

General Electric Company

'l 175 Curtner Avenue i

San Jose, California 95125 j

Dear Mr. Klapproth-l By letter dated April 7,1993, Philadelphia Electric Company (PEco) submitted l

NEDC-32163P, " Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3 i

SAFER /GESTR-LOCA Loss-of-Coolant Accident Analysis," Class III, dated January i

1993.

By letter dated July 16, 1993, PECo submitted a report entitled l

" Statistical Analysis of Small Break LOCA Upper Bound PCT for Peach Bottom j

2/3."

Included in PECo's submittal was your affidavit, dated July 15, 1993, i

requesting that the report be withheld from public disclosure pursuant to 10 -

1 CFR Part 2.790.

I You requested that the information identified in PEco's July 16, 1993, letter, be classified as proprietary because it contains details of supporting data and analyses relative to the application of the SAFER /GESTR computer program.

You stated that this program is intended for use as the licensing basis for'

.f boiling water reactor response to loss-of-coolant accidents and that the program was developed at substantial cost.

You stated that the submitted I

information should be considered exempt from mandatory public disclosure for the following reasons:

1.

The information discloses a process, method, or apparatus, including l

supporting data and analyses, where prevention of its use by General Electric's competitors without a license from General Electric constitutes a competitive economic advantage over other companies.

2.

The information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the

( j design, manufacture, shipment, installation, assurance of quality, or

\\i licensing of a similar product.

We have reviewed your application and the material in accordance with the requirements of 10 CFR 2.790 and, on the basis of General Electric's statements, have determined that the submitted information, sought to be l

withheld contains trade secrets or proprietary commercial information.

4 i

Therefore, ;~2r report, entitled " Statistical Small. Break LOCA Upper Bound PCT

]

for Peach Bottom 2/3," dated July 1993, marked as proprietary, will be withheld-from public disclosure pursuant 10 CFR 2.790(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended.

9309000302 930823

mac191

~'\\

- o-02n g

P PDR sw i

4 Mr. Janes F. Klapproth August 23, 1993 Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents.

If the need arises, we may send copies of this information to our consultants working in i

this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.

If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC.

You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information.

In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely,

/S/

Joseph W. Shea, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc: See next page DISTRIBUTION Docket File NRC & Local PDRs PDI-2 Reading SVarga JCalvo MBoyle JShea M0'Brien 0GC-MPSiemien RJones ACRS(10)

EWenzinger, RGN-I CAnderson, RGN-I

_/

OFFICE PDI/ht1/

PDih/Pli MYhhc OGC evf PDI-2/D.

NAME MdheI J

kJo/es MPSibNitN MBoylek DATE

/f[/93

%'/l(493 I/[h/93 3 //$/93 T/8/93

/

Mr. James F. Klapproth August 23, 1993 Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents.

If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.

If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You also should understand that the NRC may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information.

In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sinc re'y, 1

0

+

l 1

C ose W. Shea, Project Manager hroj t Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc:

See next page I

i i

1.

Philadelphia Electric Company Peach Bottom Atomic Power Station, Units 2 and 3 CC*

l J. W. Durham, Sr., Esquire Mr. William P. Dornsife, Director Sr. V.P. & General Counsel Bureau of Radiation Protection Philadelphia Electric Company Pennsylvania Department of 2301 Market Street, S26-1 Environmental Resources Philadelphia, Pennsylvania 19101 P. O. Box 2063 Harrisburg, Pennsylvania 17120 Philadelphia Electric Company ATTN: Mr. D. B. Miller, Vice President Board of Supervisors Peach Bottom Atomic Power Station Peach Bottom Township Route 1, Box 208 R. D. #1 Delta, Pennsylvania 17314 Delta, Pennsylvania 17314 Philadelphia Electric Company Public Service Commission of Maryland ATTN:

Regulatory Engineer, Al-2S Engineering Division Peach Bottom Atomic Power Station ATTN: Chief Engineer Route 1, Box 208 231 E. Baltimore Street Delta, Pennsylvania 17314 Baltimore, MD 21202-3486 Resident Inspector Mr. Richard McLean U.S. Nuclear Regulatory Commission Power Plant and Environmental Peach Bottom Atomic Power Station Review Division P.O. Box 399 Department of Natural Resources Delta, Pennsylvania 17314 B-3, Tawes States _0ffice Building Annapolis, Maryland 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission Mr. George A. Hunger, Jr.

475 Allendale Road Director-Licensing, MC 52A-5 King of Prussia, Pennsylvania 19406 Philadelphia Electric Company Nuclear Group Headquarters Mr. Roland Fletcher Correspondence Control Desk Department of Environment P.O. Box No. 195 201 West Preston Street Wayne, Pennsylvania 19087-0195 Baltimore, Maryland 21201 i

Carl D. Schaefer External Operations - Nuclear r

Delmarva Power & Light Company P.O. Box 231 Wilmington, DE 19899 i

John Doering, Chairman Nuclear Review Board Philadelphia Electric Company 955 Chesterbrook Boulevard Mail Code 52C-1 Wayne, Pennsylvania 19087

.