DEVIATION REPORT n'

C mm:nwrith Edison DVR NO.

j -

y 82 - 28 STA UNIT YEAR NO.

P AF,T I l TITLE OF CEVIATION OCCURRED 03MAY82 1230 Wastewater Treatment Fact 1ity Out of Spec pH OATr y s a,e r SYSTEM AFFECTED PL ANT STATUS AT TIME OF EVENT TESTING 0

0 0

Q Wastewater Treatment WDE Dafon1

. PnR(M AT) to,3cy g3 DESCRIPTION OF EVENT A sample of wastewater treatmet facility e"luent was analyzed and a pH of 3.8 was found.

It is suspected that the cause was due to acid cleaning of Unit 2 floors before painting.

10 CFRSO.72 NRC RED PHONE NOTIF ICATION MADE YES NO EQUIPMENT F A ILURE None BYES NO AORK REOUEST NO.

RESPONSIBLE SUPERVISOR F. R. Lawless DATE 05MAY82 PART 2lOPERATINGENGINEER'SCOMMENTS If this is an NPDES violation, it is reportable per T.S. 3.2 Aco. B within 10 days.

t-EkENT OF PU BL 'I C I N TEREST 24-HOUR NRC NOTIFICATION RE0'D TELEFH I

0 TECH. SPEC. VIOLATION NCN REPORTABLE OCCURRENCE T E LE GM/ TEL E COPY I4 DAY PEPO RT A BL E / T. S.

REGION lli DATE TIME

@ 20 DAY RE*0RTABLE/M. App. B,3. 2 Ceco CORPOR ATE NOTIF IC ATION MADE IF ABOVE NOTIFICATION IS PER 10CFR21 ANNUAL /SPECL REPORT RE0'O A.I.R.

S-DAY ARITTEN REPORT RE0'D PER 10CFR21 NA NA t.E.R.

TELEPH CECO CORPORATE OFFICER DATE TIME PRELIVINARY REPCRT J. G. Marshall 5/4/82 COMPLETED AND REVIEAED OPE 4 ATi% ENGINEER DATE IN\\EST6 GATED REPORT & RESOLUTION f,/s1 [ b k

[-fc.$ 6 ACCEPTED BY STATION REVIEA Ab A Clario u

)'bbY W WN SW

,d.,'

y g --

o a

/

f/

fgy

'Es:LcTiCN AFAR 0vrn m 8205240542 820507 PDR ADOCK 05000373 hg SfAT-N sUPERINTENOENT DATE S

PDR

1.

DVR Number:

1-1-82-28 11.

LaSalle County Station:

Unit 1 Ill. Event

Description:

Wastewater Treatment Facility (WWTF) effluent pH of 3 8 S.U. on grab sample of 03MAY82, analyzed on 03MAY82.

This was an N.P.D.E.S. permi t violation, exceeding permi t limits of 6.0 - 9 0 S.U.

for pH.

IV.

Probable Consequences of Occurrence:

Safe operation of the unit was maintained at all times and the health and safety of the public.vas not affected by this event.

The WWTF was shutdown immediately follow'ng notification of analytical results.

This is not a frequent occurre1ce.

V.

Cause:

It was originally suspected to be due to acids used on floor cleaning prior to painting.

Further investigations have shown an acid drain line used in Makeup Demin. regenerations was leaking. This acid was then flushed to the M.U.D. Clean Sump, 0WM05, and subsequently transferred to the WWTF without further treatment.

VI.

Corrective Action:

The acid drain line has been taken out of service and repairs are pending. The WWTF equalization tank and clearwell have been neutralized.

The M.U.D. Clean Sump, OWM05, has been neutralized.

The floor drain near the acid drain line has been plugged to prevent further occurrences of this type.

w Prepared by:

/c

[2.

l l

o

.~--

Commonwo-ith Edison

' b.

LaSalle County Nuclear Station v

LJ(7 i Rurci Routs #1, Box 220

\\ g.,,8 Mirstillas. Illinois 61341 F

V' Teleonone 815/357 6761

~

i l

May 5, 1982

..S. Envi ronmenta l Protecti ve Agency he; ion V, Enforcement Division AYTN:

Chief, Compliance Unit 21 South Dearborn Street Ch. ago, IL 60604 t ilinois Environmental Protection Agency Division of Water Pollution Control Comaliance Management Unit 2202 Churchtli Road i

Springfield, IL 62706 SUSJECT: NPDES Noncomaltances for LaSalle County"r.uclear Generating

~

Station Perrit No. ILOO48151 l

Dear Sir:

c-cance vi:- ?:endard Cendit ior 12. we

.t i r ' :: sub-i the followine

e5 cf noncorr
i a :ce, wnich are li s ted enrcer iopicall. i r. tne attachec
a:1e.

The Coclir.; Dond was bio.-ting cown as of 2 Ma/ 82.

nert are a~.

cuestions, clease contact Mr. Onaries L.

. ash of my staff,

~

a: f315; 357-6761. extension 235 p,

./

n,,;. s'd.W.4W4 y

Pc H. Holyoak Station Superintencen:

@fb RHri/FRL/CLH/msj cc:

Di rector of Water Quality, Envi ronmental Af fai rs Manager, Nuclear Stations Division e-e

-+,-r-ev--r

-,.y,-,.w...

I 1

L LASALLE COUNTY NUCLEAR GENERATING STATION N.P.D.E.S. PERMIT NO:

ILOO48151 NONCOMPLIANCE REPORT

~

DIFCliARGE NCEET A';D DESCRIPTIO :: 001

- Lov L l u e Was te Was tewa te r Treatnent Facili ty (WTF)

PA:EETER A';D PED'IT LIMIT:

Tota 1 i ror., 1.O r;/I NONCO39LIANCE, DATE, AND DUPATION:

2.6 ng/l, 20A;2r82, unknown CAUSE _OF NONCO)?'IANCE:

Due to low water cressure at the Alum and Polymer skids, insufficient chemical acdi tion resul te: in poor coagulation and settling in the cla rifiers at the WT F.

This conci : ion pernii tted i ron, in the forr of finely divided solids,

c cass througb :ne media filters.
c.,,..., - ~ IVE n. r. n.-...

o T-is conditicr.as oeen correcte: cy nanua. O co.,: rc i i i ne :re mium and icivmer acci:: ens.

inis.as correcte c r,.a nr - :. - as e result c' a :revious non-

c ;ilance co- :: :nis same crc:ier.

Tnis a: tic-tili con:inue until a re-aner: reso' :!cn :c tne io.. wa:e r cres sure 4 nade.

DATE RECOGNIZED M A VIOLATION _:

2n App 8?

30 APR 82 DATE INVESTIGATED:

i

.,' /

s LASALLE COUNTY NUCLEAR GENERATING STATION N.P.D.E.S. PERMIT No:

ILOO48151 NONCOMPLIANCE REPORT DISCHARGE NO!3ER AND DESCRIFTION: 001c - Lo,i Volume Waste was tewate r Treatment Faci 1i t'-

(WTF)

PARAMETER AND PERM!T LIMIT:

pH, 6.0 - 9 0 S.U.

NCNCOMP'.IANCE, DATE, AND DL* RATION:

3.8 S.U., 03 MAY 82, unknown CA*JSE OF NONCC.9 LIANCE:

An acid drain line leak in the Make-up Demin. Room was flusned to the floor" crains leadino eventually to the Wastewater Treatment Facili ty.

=-

0 c

CORRECTI'.*E ACTION:

-ne crain. int nas oeer. Ou: c.;; ci servi:: a,: recei s a e :endinc.

Tne LTF

aalization tan,; pH nas oeer neutra'ize: :, ca.:s :I : a::itier.L.

Tnt ficor rains nave teen neutrali:e:.

1 03 MAY 82 DATE RECOGNIZED AS,A VIOLATION:

04 MAY 82 DATE INVESTIGATED:

.