RO 77-29:on 770812,during Test,Set of Integral Poppet Check Valves & External Discharge Check Valve Associated W/Each Rod Drive Pump Leaked Excessively.Caused by Wear Over Long Operating Time of Equipment
ML20038A043
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 08/25/1977
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
References
RO-77-29, NUDOCS 8109110182
Download: ML20038A043 (1)


Text

..

UCENSEE EVENT REPORT sig acek Fein:

CCNinCL etCCx:1 l ! ! I l l ptsass passt ALL assuman assomasafiow) 1 6

"X uco.= = =

"J' cn lwir131,l3 li i f o l n i-lo i o f o f oia l-l o l o f 11. l 1 II l li il lo11l 7 89 14 13 a3 is JO 31 32 W 203 ccorr.

m,n e m worom cai Corrr l l l W y l 0l 5l0 l-l 01115l5 l l 0l Sll [2 l 7 l 7[ l0 l* l2 l 5 l 7l 7l 7 8 57 ed 29 60 61 e.d 68 74 73 eQ EVENT CESCRPT1CN g [ During routine Type C contain=ent leak tate cocpone=t tescian,, one set of integral 7 89 80 Q l poopet check valves and the external discharze check val re associated with each rod l 7 89 80 Q l drive eu=ra leaked excessivelv. Tuel handline activit r in the fuel sool was halted l 7 i9 60

@ l until satisfactor r contairent int scrit-r was serif tee within f. hours. Not reeeti-l 7 89 oO is ieive.

R0-77 -79

[

7 89 m

60 m ens Cc0E CCCI CoM8CostNr CCCE N

NW WCL.7tre cv I si ni Ltj Ivis it Ivi tixl L3J l*:1015151 LIJ 7 89 to 11 12 17 43 44 47 48 CAuSE CESCAPTICN I Failure attributed to wear over lena c:erating time of ecuiccent. Thisisfirst_J 7 89 20 0 19 l recuired testin2 of these ecSoonent9 in fifteen vears. ?e9 air of the SoDOets is I

7 89 80 i te l under evaluation. The external check valves vill not be recaired but an (CCSTD) l

~

.,.,e,,

e,.1u

.c c,o u

=

occ= -

ose:- :-

LeJ loIof ol I m I L3J l s/*

I 7 8 9

10 12 13 44 65 44 80

,c e,

ACTMTV u tp.t CCN mems um u<x,r,acn m tocaro e, asum 8

(zj

[1J l N/A I

l n/A i

7 8 9

10 11 44 45 60 PERSCNNEL EXPCSURES l

weta evet et3005mCN l

810101 o f L;j l_x/A l

7 89 11 12 13 80 PERSCNNEL NJUAES esupeEm CE3CAPnope E 1010101 I s/A 1

7 89 11 12 60

(

PROBABLE CONSEQUENCES l

7@d 9l None. The second set of poemet checks tested in each pu=p tested satisfactorily.

l e0 LCSS CR DAMAGE TO FAC:UTY tver cascarnen 8 lil i F'A 1

7 89 10 eQ PUERJC!1Y

)

] l None l

7 89 60 ACCff10NAL FACTCAS

@ l (cf.use Descriptien - Centd) additienal check valve in the 2" suoply line ce==on l

7 89

,0 OI to both pumps will be installed and tested during the presenc outage.

t l

7 89 gg I

r 8109110182 770825 PDR sDCCK 05C00155 i