Sample ID:
142514 Type: RLSSS Type Detail: SAND
==
Description:==
140523BD01 BACKGROUND HELO# 1
!Common!
Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA LQ~l!!J Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/10/1411:08 Mat. SizeNolume:
1662 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
HELO -# 1 I Collection I Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA L~!c~ss**1 Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes l!-.Q~atio_!!J Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/2014 11 :51 Sample Date: 05/23/1411:05 Sample SizeNolume: 1662 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142514 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140523BD01 BACKGROUND HELO# 1 Analysis Geometry MCAID Quant.
Units Method FP/AP Lab Analy~is By A_ 1 L_marinelli_sand_
1009 1662GR
.000 DYNES, WILLIAM J Isotope Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments 0
K-40 NT 0.00001792 2.05E-6 88.613%
40 0
TL-208 NT 4.216E-7 1.024E-7 r
2.085%
208 0
PB-212 NT 6.172E-7 1.861E-7 r
3.052%
212 0
81-214 NT 4.931E-7 1.403E-7 r
2.438%
214 0
PB-214 NT 7.709E-7 1.985E-7 r
3.812%
214 0
BE-7 AP 8.6887E-7 Iv 0.000%
7 0
54 0
MN-56 AP 1.4064E-7 IV 0.000%
56 0
C0-57 AP 1.0143E-7 IV 0.000%
57 0
C0-58 AP 3.3688E-8 IV 0.000%
58 0
C0-60 AP 1.4036E-7
[if 0.000%
60 0
SB-124 AP 5.6927E-8 IV 0.000%
124 0
SB-125 FP 3.2566E-7 Iv 0.000%
125 0
CS-134 FP 7.0614E-8 Iv 0.000%
134 0
137
[ An_alysis Review Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Rad Mat Present:
Yes 06/19/2014 11 :51 Rasterized: r Date Mod ID Mod Date 06/10/14 11 :58 Mod Id Mod Date Date: 06/11/14 08:16 Page 2 of 3
Sample ID:
142514 Type: RLSSS Type Detail: SAND
==
Description:==
140523BD01 BACKGROUND HELO# 1
[---------- --1 Review/Approve Reviewed: COOPER, TERRY L Comments:
Disp9sition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/201411:51 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/11/14 08:16 Disposition Result: Sample contains only natural isotopes Final Apprnval Date: 06/11/14 08:16 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 10-JUN-2014 11:53
>>>>> SAMPLE PARAMETERS <<<<<
*~
...... ci-t.l~:~U-0.5.2.3.BD.0-l,,...BACKGROUNJ:i-HELO~#-,,----==-~~---~~~-=---*o...,...-------*
- ID 1009 Acquisition date: 10-JUN-2014 11:50:39 *
- Start Time:
- Stop Time:
- Quantity
- Geometry 10-JUN-2014 11:50:00 10-JUN-2014 11:50:00
- 1. 66200E+03 GR A lL marinelli sand 1 Operator: BILL Counting System IHPS Sample Number:
Analysis Library DYNES UlGSP 142514 HP NATURAL
>>>>> A -1922924
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.26 0 00:03:00.33 0.0%
l.OOOOOE+OO 8.00000 PARAMETERS<<<<<
Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 10-JUN-2014 00:04
-l.04456E-01 4.99840E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
77.37 34 53
- 1. 56 155.00 151 9 42.0 l.62E+OO BI-214 PB-212 PB-214 1
238.66 58 57
- 1. 48 477.65 473 13 29.9 9.46E-01 PB-212 1
295.39 27 4
- 1. 98 591.14 587 13 25.4 l.50E+OO PB-214 1
351.92 63 3
- 1. 42 704.23 697 13 14.4 5.73E-01 PB-214 1
583.43 25 2
2.20 1167.32 1163 11 23.6 5.08E-01 TL-208 1
609.05 22 4
- 1. 43 1218.56 1213 10 28.1 3.50E-01 BI-214 1
1460.83 95 3
- 1. 89 2922.03 2916 12 10.9 4.45E-01 K-40
Page :
2 Surrunary of Nuclide Activity Sample ID: 1009 Acquisition date 10-JUN-2014 11:50:39 Total number of lines in spectrum 7
Number of unidentified lines O
N.umbftr=4L,,li.n.e.a....:t.eI1:t.st.ti.JLeJ.y_i.de.n:ti£i.e.d_by __ NID_. -7.-~~-_
_.,._ CW~~-DJ)..%..
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error K-40 1.28E+09Y
- 1. 00
- 1. 792E-05
- 1. 792E-05 0.205E-05
- 11. 46 TL-208 3.05M
- 1. 60 2.627E-07 4.216E-07 1.024E-07 24.29 PB-212 10.64H
- 1. 00 6.158E-07
- 6. 1 72E-07 1.861E-07 30.15 BI-214 19.90M
- 1. 08 4.574E-07 4.931E-07 l.403E-07 28.44 PB-214 26.80M
- 1. 06 7.291E-07 7.709E-07
- 1. 985E-07
- 25. 75 Total Activity 1.999E-05 2.023E-05 Grand Total Activity :
1.999E-05 2.023E-05 Manually accepted Flags: "K" "E"
Keyline not found Manually edited "M"
"A" Nuclide specific abn. limit Flags A
A A
A A
Unidentified Energy Lines Sample ID : 1009 None Page :
3 Acquisition date 10-JUN-2014 11:50:39
Interference Report Sample ID: 1009 No interference correction performed Acquisition date Page :
4 10-JUN-2014 11:50:39
Nuclide Line Activity Report Page :
5 Sample ID : 1009 Acquisition date 10-JUN-2014 11:50:39 Nu&-1-i-El e-T-yi:,e+c-na-t;.u-Fa-1.
Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 95 10.67*
4.482E-01
- 1. 7 92E-05
- 1. 7 92E-05
- 11. 46 TL-208
- 72. 80 2.14 l.155E+OO Line Not Found 74.97 3.60
- 1. 239E+OO Line Not Found ------
84.79 ------
- 1. 27 1.578E+OO Line Not Found ------
252.45 0.80
- 1. 887E+OO Line Not Found ------
277.28 ------
6.80
- 1. 783E+OO Line Not Found ------
510.61
- 21. 60 1.121E+OO Line Not Found ------
583.02 25 86.00*
9.948E-01 2.627E-07 4.216E-07 24.29 763.06 ------
- 1. 64 7.714E-01 Line Not Found ------
860.30 ------
12.00 6.870E-01 Line Not Found ------
PB-212 74.81 ------
10.50 1.233E+OO Line Not Found ------
77.11 34 17.70 l.329E+OO
- 1. 311E-06 l.314E-06 42.30 87.19 ------
6.27 l.650E+OO Line Not Found ------
90.13 ------
- 1. 86
- 1. 7 30E+OO Line Not Found ------
115.12 0.59 2.162E+OO Line Not Found ------
238.58 58 43.60*
- 1. 948E+OO 6.158E-07
- 6. 1 72E-07 30.15 300.03 ------
3.34 l.694E+OO Line Not Found ------
BI-214 76.86 34 0.58 1.329E+OO 4.002E-05 4.314E-05 42.48 79.29 0.97 1.397E+OO Line Not Found ------
609.31 22 46.10*
9.561E-01 4.574E-07 4.931E-07 28.44 665.44 ------
- 1. 56 8.797E-01 Line Not Found ------
768.35 ------
4.88 7.663E-01 Line Not Found ------
806.16 ------
- 1. 23 7.315E-01 Line Not Found ------
934.04 3.16 6.352E-Ol Line Not Found ------
1120.27 15.00 5.391E-01 Line Not Found ------
1155.18
- 1. 69 5.255E-01 Line Not Found ------
1238.11 ------
5.92 4.976E-Ol Line Not Found ------
1280.95 ------
- 1. 4 7 4.855E-01 Line Not Found ------
1377.66 ------
4.02 4.629E-01 Line Not Found ------
1385.30 ------
0.78 4.614E-01 Line Not Found ------
1401.48 ------
- 1. 39 4.583E-01 Line Not Found ------
1407.97 ------
2.48
- 4. 571E-01 Line Not Found ------
1509.22 2.19 4.415E-01 Line Not Found ------
1583.22
- 0. 72 4.336E-01 Line Not Found ------
1661. 26 1.15 4.280E-01 Line Not Found ------
1729.58 ------
3.05 4.255E-01 Line Not Found ------
1764.49 ------
15.90 4.249E-01 Line Not Found ------
1847.41 2.12 4.256E-01 Line Not Found ------
PB-214 53.17 1.10 3.707E-01 Line Not Found ------
74.81 6.52 1.233E+OO Line Not Found ------
77.11 34
- 11. 00 1.329E+OO 2.llOE-06 2.231E-06 42.32 87.19 ------
3.88 1.650E+OO Line Not Found ------
90.13 ------
1.15
- 1. 7 30E+OO Line Not Found ------
241. 92 7.46 1.933E+OO Line Not Found ------
258.94 0.55 1.859E+OO Line Not Found ------
295.09 27 19.20*
- 1. 712E+OO 7.291E-07 7.709E-07
- 25. 75 351. 87 63 37.10 1.515E+OO l.004E-06 1.062E-06 15.10 785.83 1.09 7.498E-01 Line Not Found ------
839.00 0.59 7,038E-01 Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 1009 Acquisition date 10-JUN-2014 11:50:39 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
7 Sample ID : 1009 Acquisition date 10-JUN-2014 11:50:39 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 4.
477.61 8.6887E-07 MN-54
- 3.
834.83 l.3525E-07 MN-56
- 3.
846.81 1.4064E-07 C0-57
- 16.
122.06 1.0143E-07 C0-58
- 0.
810.79 3.3688E-08 C0-60
- 1.
1332.50 1.4036E-07 SB-124
- 0.
602.73 5.6927E-08 SB-125
- 6.
427.88 3.2566E-07 CS-134
- 1.
604. 71 7.0614E-08 CS-137
- 5.
661. 66
- 1. 5992E-07