s' y

1 TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II August 11, 1981 HTRD-50-518/81-16, -518/81-12,

-520/81-14, -521/81-12 ggt,K'M g~

PBRD-50-553/81-17, -554/81-11 s' eEC[lk k)

Mr. James P. O'Reilly, Director p

',d CJ7

[

l Office of Inspection and Enforcement 4

l h ;-

[

Q 844 g%=%

U.S. Muclear Regulatory Commission Region II - Suite 3100 8

0 y/

101 Maristta Street h

L Atlanta, Georgia 30303

/

16

~

Dear Mr. ')'Reilly:

g c

HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - REPORTABLE DEFICIENCY -

ENVIRONMENTAL QUALIFICATION OF NSSS EQUIPMENT TO IEEE-323-1974 -

HTRD-50-518/81-16, -519/81-12, -520/81 9 4, -521/81 PBRD-50-553 /81-17, -55D /81-11 The subject deficiencies were initially reported to NRC-0IE, Region II, Incpector D. Quir'< on July 10, 1981 as NCR's HTA NEB 81-04, HTB NEB 81-05, and PBN NEB 81-03 In compliance with paragraph 50.55(e) of 10 CFR Part 50, we are enclosing the first interim report on the subject deficiencies. We consider 10 CFR Part 21 applicable to this nonconformance. TVA anticipates transmitting the next report on or before November 16, 1981.

If you have any questions, please call Jim Domer at FTS 857-2014 Very truly yours, TENNESSEE VALLEY AUTHORITY

'L. N. l.

I i

Mills, Manager Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 f

s.h n108180163 810811

'P'DR ADOCK 05000518 PDR S

An Equal Opportunity Employer

,e s

ENCLOSURE HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS ENVIRONMENTAL QUALIFICATION OF NSSS EQUIPMENT TO IEEE-323-1074 10CFR50.55(e) REPORT HTRD-50-518/81-16, -510/81-12, -520/81-14, -521/81-12 PBRD-50-553 /81 -17

-554/81-11 REPORT NO. 1 (INTERIM)

Description of Deficiency General Electric has failed to qualify Nuclear Stean Suppiv Systen (MSSS) equipment to IEEE Standard 323-1o74 as stated in GESSAR and as required by the STRIDE contracts. Instead, some equipment was qualified to IEEE Standard 323-1971.

Jn erin Progress GE is in the process of evaluating this deficiency to determine the necessary corrective action for the subject nonconforming condition.

TVA expects to supply your office with ac:ditional information by November 16, 1c81.

l 1

l L