ML20028G661

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Defective Weld & Unidentified Bolting Matl in Boric Acid Transfer Pumps.Initially Reported on 830113.Evaluation in Progress.Next Rept Will Be Submitted by 830516.Also Reported Per Part 21
ML20028G661
Person / Time
Site: Harris  Duke Energy icon.png
Issue date: 02/08/1983
From: Parsons R
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
CON-NRC-42, REF-PT21-83 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8302170248
Download: ML20028G661 (1)


Text

..

. CD&L Carolina Power & Light Company P. O. Rox 101, New Hill, N. C.

27562 ca February 8, 1983 r,

20 3

O Mr. James P. O'Reilly NRC-42

~

United States Nuclear Regulatory Commission 2.

C I

Region II 101 Marietta Street, Northwest (Suite 3100)

Atlanta, Georgia 30303 C"

CAROLINA POWER & LIGHT COMPANY SHEARON HARRIS NUCLEAF POWER PLANT 1986 900,000 KW - UNITS 1 & 2 BORIC ACID TRANSFER PUMPS, WESTINGHOUSE SHOP ORDER 205, ITEM 113

Dear Mr. O'Reilly:

On January 13, 1983, Mr. A. Hardin of the NRC was notified of a potentially reportable item per the provisions of 10CFR50.55(e) and 10CFR, Part 21.

The boric acid transfer pumps from the vendor (Crane Company) contained weld deficiencies and unidentified bolting material. At the present time, Westing-house is still evaluating these discrepancies and do not expect to be complete until April 30, 1983. For this reason, we would request an extension until May 16, 1983 for submitting a report on the reportability of this item.

Thank you for your consideration in this matter.

1 Yours very truly, W

M*M R. M. Parsons Project General Manager Shearon Harris Nuclear Power Plant RMP/sh l

cc:

Mr. G. Maxwell (NRC-SHNPP)

Mr. V. Stello (NRC) i OFFICI AL COPY, 18 '?

8302170248 8'30208 PDR ADOCK 05000400 PDR g

w