ML19308C779

From kanterella
Jump to navigation Jump to search
Forwards LER 79-118/03L-0
Date released: 11/18/2019 Download: ML19308C779


LER 79-118/03L-0:on 791231,drywell Atmosphere Monitor a Failed While Monitor B Was Out of Svc,Resulting in Degraded Mode.Apparently Caused by Presence of Moisture in Sample Lines Causing Failure of Sample Pumps & Monitor Detector
ML19308C780
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 01/28/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19308C780 (2)
Forwards LER 79-118/03L-0
ML19308C778
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 01/28/1980
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19308C778 (1)