  1. pn arc o

~

'o UNITED STATES g

8 )

s, g

NUCLEAR REGULATORY COMMISSK'N 3 pf

' iy REGION IV S

611 RYAN PLAZA DRIVE, SUITE 1000

%~

k ' \\-

o AR LINGToN, TE X AS 76012 O

g 15 AUG 1979 VIA AIR M AIL.

Docket No. 99900036/7942 G. Dikkers and Company N.V.

ATTN:

Mr. C. S. Craig Chief Executive Industriestraat 15, P. O. Box 12 7550 AA Hengelo, Province of Overijssel The Netherlands Centlemen:

Thank. you for your letter of July 18, 197-), in response to our letter dated June 23, 1979. As a result of our review, we find that additional information is needed on the following items:

A.

The adequacy of your corrective action measure would appear contin 3ent on past use of this welding procedure specification in production welding no exceeding a 180 C maxi =un interpass tenperature: Accordingly, please identify what actions were taken to assure that this was in fact the case. Your response also fails to provide any steps that have been or will be taken to preclude recurrence of similar deviations in the future.

B.,

Please re-evaluate your stated corrective action. for the specific part, sitice we believe ASME Code compliance cannot he establihhed until the welder,,in question, has been appropriately qualified for the observed position.

B, C, G, and H.

Please identify how the stated instructions to personnel were documented to provide an auditable record of corrected action.

Please provide this additional information within twenty (20) days in order that we may complete our review in a ti=ely manner.

Sincerely,

\\-

Uldis Potapov', Ch)hV

'cf Vendor Inspection hranch 122? 006 7910800

--