RESPONSES TO REVISED NRC DSE FOR PA-ASC-1169 5/14/19 Page 3, Lines 22 - 31 of Revised DSE It is not clear what the purpose is to reference Appendix S of 10 CFR 50. Depending on the vintage of licensing for plants, Appendix S of 10 CFR 50 as well as Appendix A of 10 CFR 100 may not be the licensing basis.

Page 16, Line 45 of Revised DSE Typo - forf should be for.

Page 17, Lines 22 - 28 of Revised DSE The proposed changes on Page 16, Lines 13 - 19 of the PWROG comments on the original DSE were not incorporated. NRC response to PWROG Comment 1 was not incorporated (refer to NRC response matrix on PWROG comments.)