ML19141A219

From kanterella
Jump to navigation Jump to search
ROP Monthly Meeting, Presentation Slides, May 22, 2019
ML19141A219
Person / Time
Issue date: 05/22/2019
From: Tekia Govan
NRC/NRR/DIRS/IRGB
To:
Govan T, 415-6197, NRR/DIRS
References
Download: ML19141A219 (24)


Text

ROP Monthly Meeting May 22, 2019 10:00 am - 12:15 pm

Agenda 10:00 am Introduction/Opening Remarks 10:15 am Update on Changes to the Engineering Inspection Program D. Bollock 10:45 am Operating Experience - Brunswick CryoFit Coupling Failure J.Carneal 11:00 am FAQ 19 Brunswick CryoFit Coupling Failure NEI 11:15 am Transition of FAQ 19-01 to Final Approval J.Quinones 11:20 am NEIs Response Letter on the 3/27/19 Executive ROP Meeting NEI 11:40 am ROP Enhancement - Next Steps R. Gibbs 12:00 pm Opportunity for Public Comments Members of the Public 12:10 pm Closing Remarks NRC Management 12:15 pm Adjourn 2

Update on Engineering Inspections Douglas Bollock NRR/DIRS/IRIB 3

Engineering Inspection Implementation Plan

  • Draft Inspection Procedures (IPs) complete -

June 2019

  • Develop and deliver training on new procedures for NRC staff

- Inspection procedure changes, ties to the regulation, examples of more than minor findings, lessons learned from previous inspections

  • Inspection scheduling and inspection implementation 4

Focused Engineering Inspections

  • Selection Criteria for Focused Engineering Inspections (FEIs)

- Risk significance, including PRA insights and common cause failure potential

- Operating Experience, including past industry performance trends in SSC failures and insights from NRC inspections

- Potential for challenges, including changing conditions, which would not be identified through other inspections.

5

Next Steps

  • Inform the Commission of staff selections for FEIs.

- Fire Protection (FP) FEI replaces current triennial FP and Power-Operated Valves (POV) replaces Environmental Qualification

  • Work with regions to make adjustments to inspection schedules 6

Questions?

Brunswick Unit 1: RCS Leak - NOUE and Manual Scram Jason Carneal NRR/DIRS/IOEB

RCS Leak -

Event Timeline

  • Unit 1: Operating at 100% power on 03/28/2019
  • NOUE declared at 14:50 for leak rate greater than 10 gpm for 15 minutes
  • Indications of leak from reactor vessel level reference leg because of erratic readings
  • Licensee cooled down to Mode 4. Terminated NOUE on leak rate below 10 gpm 9

CryoFit Coupling Failure

  • Leak was identified on 1-inch CryoFit Coupling
  • Coupling supplied by Raychem (defunct in 1999)
  • Expands when cooled / contracts to original shape when warmed to ambient temperature
  • Forms metal to metal swaged connection with pipes and CryoFit compatible fittings
  • Susceptible to hydrogen embrittlement in water environment at high temperatures, pressures and when in the presence of hydrogen 10

CryoFit Coupling 11

Seabrook Failures (1991)

  • NRR performed operating experience search of licensee event reports, inspection reports and other data looking for existence of CryoFit failures
  • Identified a fracture of a CryoFit coupling on a pressurizer gas space sampling line (360° circumferential fracture at midpoint of coupling)
  • A second CryoFit coupling in the same line fractured in a similar manner after an accidental physical impact during repair.
  • No other known failures of CryoFit couplings since.

12

Extent of Condition

  • Only identified failures were the previously discussed failures at Seabrook in 1991
  • Working with INPO to help verify extent of condition and raise industry awareness of the event.
  • Possibly work with NEI to validate extent of condition 13

Remaining Questions

  • Extent of Condition?
  • Was failure mode actually hydrogen embrittlement?
  • Possible material aging component that could cause hydrogen embrittlement in addition to the known causal factors related to high temperature, pressure and hydrogen concentration?

14

Questions?

FAQ 19 Brunswick Reactor Coolant System Leakage Nuclear Energy Institute 16

Transition of FAQ 19-01 to Final Approval Joylynn Quinones-Navarro NRR/DIRS/IRAB 17

Proposed SECY on ROP Enhancement Nuclear Energy Institute 18

ROP Enhancement Next Steps Russell Gibbs NRR/DIRS/IRAB 19

ROP Enhancement -

Longer Term Activities (1)

  • Perform holistic review of problem identification and resolution (PI&R) inspections
  • Examine effectiveness of the Cross-Cutting Issues Program

ROP Enhancement -

Longer Term Activities (2)

  • Evaluate changes to supplemental inspection for White findings (IP 95001)
  • Optimize independent spent fuel storage installation and radiation protection inspections
  • Evaluate crediting licensee performance in other safety cornerstones for emergency preparedness inspection findings 21

Questions?

Opportunity for Public Comments Members of the Public 23

Closing Remarks NRC/NEI Management 24