ML17300A784
ML17300A784 | |
Person / Time | |
---|---|
Site: | Palo Verde |
Issue date: | 04/23/1987 |
From: | Haynes J ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
References | |
161-00167-JGH-P, 161-167-JGH-P, TAC-64676, TAC-64677, TAC-64678, NUDOCS 8704300211 | |
Download: ML17300A784 (35) | |
Text
REGULATOR FORNAT ION DISTRIBUTION 'S EN (R IDS)
ACCESSION NBR: 870430021 1 DOC. DATE: 87/04/23 NOTARIZED: NO FACIL: BTN-50-528 Palo Vev de Nuclear Station> Uni t 1> Arizovva Pub li DOCKET 05000528 I
STN-50-529 Palo Vev d e Nuclear Stat i on> Uni t 2> Av'i zona Pub STN-50-530 Palo Vev'de Nuclear Station. Unit 3> Av'izona Publi 05000530 li 05000529 AUTH. NANE AUTHOR AFFILIATION HAYNES> S. Q. Arizona Nucleav Poser Prospect (formerly Ari zona Public Serv REC IP. NAI'1E RECIPIENT AFFILIATION Document Control Branch (Document" Control Desk)
I
SUBJECT:
Fov Mav'ds addi info re 870123 application fov. amends to Licenses NPF 41> NPF 51 Zc N>F 65> reducing bov ation requiv'ements eh en in shutdoun> per 870303 tel con fk 870401 TITLE: OR 1tr.
DISTRIBUTION CODE: A001D Submittal: Qenev COPIES RECEIVED: LTR al Distribution I ENCL / SIZE:
NOTES: Standardized plant. N. Davis> NRR: iCg. 05000528 Standardized plant. N. Davis. N~R: iCg. 05000529 Standardized plant. N. Davis> NRR: 1Cg. 05000530 RECIPIENT COPIES REC IP I ENT COP IEB ID CODE/NANE LTTR ENCL ID CODE/MANE LTTR ENCL PD5 LA 0 PD5 PD 5 5 LICITRA> E 1 DAVIS> N 1 INTERNAL: ACRB 6 6 ARN/DAF/LFNB 0 NRR/DEBT/ADE 1 NRR/DEST/ADS 1 1 NRR/DOEA/TBB 1 AS/ ILRB 1 1 OQC/HDS1 1 0 0 FIL Ol; 1 1 I EXTERNAL: EQSQ BRUBKE> B 1 LPDR NRC PDR 1 NBIC NOTES:
TOTAL NUNBER OF COPIES REQUIRED: LT1R 26 ENCL 23
I ah' j
I I 4 ~
'I
'4 V
I
', I 'll I
I ItIV E
I~ I I
,I I, N% 0 k.
t
'I I IV I I
tl I I I
I 4 I II ~
~
II V I I 4 I ll
'I 4
Arizona Nuclear Power Project P.o. BOX 52034 o PHOENIX, ARIZONA85072-2034 April 23, 1987 161-00167-JGH/PGN U.S. Nuclear Regulatory Commission ATTN: Document Control Desk tItashington D.C. 20555
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Units 1, 2, and 3 Docket Nos. STN 50-528 (License NPF-41)
STN 50-529 (License NPF-51)
STN 50-530 (License NPF-65)
Revision to Technical Specification Amendment Sections 1.0, 2.2, 3/4.1, 3/4.3, 3/4.10 File: 87-F-005-419.05 87-A-056-026
Reference:
(1) Letter from J. G. Haynes (ANPP) to G. W. Knighton (NRC) dated January 23, 1987 (PP39798).
Subject:
Technical Specification Amendment Sections 1.0, 2.2, 3/4.1, 3/4.3, 3/4.10.
(2) Telecon between Manny Licitra (NRC), Peggy Nelson (ANPP), Jim Webb (ANPP), and Dave Hoppes (ANPP) on March 3, 1987.
Subject:
Temperature Dependent Shutdown Margin Technical Specification Amendment Request.
(3) Letter from E. A. Licitra (NRC) to E. E. Van Brunt, Jr. (ANPP) dated April 1, 1987.
Subject:
Request for Additional Information Palo Verde Units 1, 2 and 3 Shutdown Margin Technical Specification Change Request.
Dear Sir:
The Reference (1) letter submitted proposed changes to the PVNGS Units 1 and 2 Technical Specifications to reduce the boration requirements when in shutdown, by modification of the shutdown margin requirements. In addition, that the change be considered as a change to the PVNGS .Unit 3 Technical it was requested Specifications.
The Reference (2) telecon and Reference (3) letter requested additional information on the amendment request. This information is provided in Attachment 1. provides revised pages to the Reference (1) letter, reflecting the additional information discussed in Attachment 1. The revised pages replace the corresponding pages in the original submittal.
By copy of this letter, we are also forwarding the revisions to the appropriate state agency.
8704300211 PDR P
ADOCK 870423 05000528 PDR II 'I
14 USNRC Document Control Desk,
Subject:
Revision to,'Techni'cal,",
Specification Amendment 161- 00167 Page 2 If you have any questions, please call M. F. Quinn at (602) 371-4087.
Very trul yours, J. G. Haynes Vice President Nuclear Production JGH/PGN/ls Attachment cc: 0. M. De Michele (all w/a)
E. E. Van Brunt, Jr.
A. C. Gehr R. P. Zimmerman J. B. Martin G. M. Knighton C. E. Tedford
ATTACEKNT 1 ANPP RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION tL Should not the new Definition 1.16 read "...assuming the fully or partially withdrawn full-length CEA..." rather than "...assuming the fully or partially inserted full-length CEA.."?
ANPP RESPONSE The definition is correct as submitted since the proposed wording would lead to the phrase "...withdrawn full-length CEA ...is withdrawn."
- 2. NRC QUESTION Many of the Figures accompanying the supporting analyses for the Technical Specification amendment request are unlabeled and some are also completely blank (e.g., Fig. 1-1, Fig. 1-2, Fig. 1-15). Please correct and update these.
ANPP RESPONSE Section H of the attachment to Reference (1) supplied the supporting analyses for the Technical Specification amendment request. Figures l-l, 1-2, and 1-15 showed core power, core heat flux, and safety injection flow, respectively, as a function of time. These figures were for a large steam line break during Mode 3. As would be expected for Mode 3, core power and core heat flux are zero for the duration of the transient. In addition, the analysis states that during the first 500 seconds of the transient the pressurizer pressure remains above the Safety Injection Actuation Signal setpoint. Therefore, safety injection flow is also zero for the duration of the transient. These figures were originally scaled such that the curve was superimposed on the horizontal axis and it appeared that the curve was omitted from the figure. To facilitate the review of this amendment request, the figures have been rescaled such that the curves do not lie on the axis. Similarly, Figures 1-17, 1-18 and 1-31 have also been rescaled.
- 3. NRC QUESTION For the proposed 1X shutdown margin when all CEAs are fully inserted, how is verification made that all CEAs are inserted? What instrumentation and/or read-out devices are used? Should this be included, in Technical Specifications (e.g., 4.1.l.l.l.a.2)?
ANPP RESPONSE Verification that all CEAs are fully inserted will be, done via the rod bottom contacts, or if these, are unavailable, via the reed switch position transmitters (RSPT). The rod bottom contacts are dedicated contacts, one for each CEA. The rod bottom contact for a CEA is closed when its associated CEA is fully inserted, and provides a readout of actual CEA position. The information is displayed to the operator in the control room via a core mimic
I ~
display in which an illuminated light indicates a CEA fully inserted. The rod bottom information is also available from the plant monitoring computer. If the rod bottom contacts are unavailable, then information from the RSPTs may be used as an alternate. There are two redundant, independent channels of RSPTs available. The information from these is available through the Control Element Assembly Calculator (CEAC) operator's modules in the control room. If the above noted indication has been made inoperable due to plant condition, e.g., during MODE 5 with RSPTs disconnected for maintenance, the Reactor Trip Breakers will be opened to insure the CEAs are fully inserted. This will be a part of the revised shutdown margin procedures which will implement the revised Technical Specification. Due to the diversity of CEA position indication which is available, it is not neccessary to include within the Technical Specification the method to be used in verifying that a11 CEAs are fully inserted.
- 4. NRC QUESTION Provide justification for deleting any reference to shutdown margin requirements in the Action statements for Technical Specifications 3.1.2.2, 3.1 2.4, 3.1.2.6.
~
ANPP RESPONSE The Action statements for Technical Specifications 3.1.2.2, 3.1.2 3.1.2.6 currently state ". . . .or be in at least HOT STANDBY and borated to a
', and SHUTDOWN MARGIN equivalent to at least 6/. hk/k at 210 F'ithin the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> . . . ." The reference to shutdown margin requirements in the action statements for Technical Specifications 3.1.2.2, 3.1.2.4, and 3.1.2.6 is redundant, since the requirement to be in HOT STANDBY automatically requires boration to a shutdown margin consistent with Technical Specification 3.1.1.1 or 3.1.1.2.
S. NRC QUESTION Discuss how the limiting CEA ejection event was reevaluated concurrent with the introduction of the K requirement to ensure that the safety analysis acceptance criteria wild 3e met.
ANPP RESPONSE The KN requirement was introduced to preclude additional evaluation of the CEA 1
ejection event. If the requirement is met, by definition, the reactor will remain subcritical if KN a single rod ejection occurs. Safety analysis acceptance criteria are met without further analysis.
- 5. NRC COMMENT In the No Significant Hazards Consideration (NSHC) Determination, changes 3, 4, and 5 are not administrative changes, but are classified as such.
ANPP RESPONSE In the NSHC Dermination, changes 3, 4, and 5 were determined to match the guidance of 51 FR 7751 by the example: (i) A purely administrative change to T.S. These changes involved:
- 3. Removing the redundant reference to the shutdown margin requirement in T.S. 3.1.2.2, 3.1.2.4 and 3.1.2.6.
- 4. Revising the reference to'hutdown margin in T.S. 3.10.1 to be consistent with the new shutdown margin requirements.
- 5. Provide a special test exception to suspend shutdown margin requirements for pre-startup testing of the control element drive mechanism system.
These changes were determined to be purely administrative since they are only necessary to maintain consistency throughout the Technical Specifications with the addition of the new shutdown margin requirements. However, to facilitate the review of this amendment request, changes 3, 4 and 5 will be classified as both an administrative change (example (i)) and: A change which may result in some increase to the probability or consequences of a previously analyzed accident, or may reduce in some way a safety margin, but where the results of the change are clearly within all acceptable criteria with respect to the system or component specified in the Standard Review Plan (example (iv)).
Accordingly, the NSHC Determination has been revised to reflect this change.
ATTACHMENT 2 Revisions to Temperature Dependent Shutdown Margin Technical Specification Amendment Request
'1 ATTACHMENT A. DESCRIPTION OF THE TECHNICAL SPECIFICATIONS AMENDMENT ~RE UEST The proposed changes to Technical Specification sections 1.0, 2.0, 3/4.1.1, 3/4.1.2 and 3/4.10.1 reduce the boration requirements when shut down, by modification of the shutdown margin requirements as follows:
K A new parameter, KN , in introduced and defined as the eff calculated assuming the partially or fully inserted rod of highest inserted worth is fully withdrawn.
- 2. Limiting Conditions for Operation (LCOs) 3.1.1.1 and 3.1.1.2 require that for Modes 1-4, the shutdown margin be greater than or equal to 6X delta K/K, and for Mode 5, greater than or equal to 4X delta K/K. The proposed changes revise the shutdown margin requirements for Modes 1-5 according to full length Control Element Assembly (CEA) position. The revised Tech Spec 3.1.1.1 is applicable when all full length CEAs are fully inserted and requires that for Modes 3-5, the shutdown margin be greater than or equal to 1X delta K/K. The revised Tech Spec 3.1.1.2 is applicable when any full length CEA is ',withdrawn and requires that for Modes 1-5, the shutdown margin be greate'r than or equal to that given in a new Figure 3.1-1A. For reactor coolant cold leg temperature less than or equal to 500'F, K 1
shall be less than 0.99.",The LCO action statements are also revised (o require, boration when the above shutdown margin requirements are not met.
Surveillance Requirements 4.1.1.1.1 and 4.1.1.2 require that the shutdown margin be verified at given time intervals to satisfy the LCO requirements. The proposed changes revise Tech Spec 4.1.1.1.1 and 4.1.1.2 to require the shutdown margin to be verified to the proposed new LCO requirements, as described above. In addition, the proposed change requires KN 1 to be determined to be less than 0.99 at least once every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
The associated Bases 3/4.1.1 and 3/4.1.2 are also revised to reflect the proposed changes.
The action statements for LCOs 3.1.2.2, 3.1.2.4, and 3.1.2.6, for Modes 1-4, require in part that when the requirements of the LCOs are not met, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and borated to a shutdown margin equivalent to at least 6X delta K/K at 210 'F. The proposed changes delete the redundant reference to the shutdown margin requirement since these are covered in Tech Spec 3.1.1.1 and 3.1.1.2.
- 4. LCO 3.10.1 currently requires that a reactivity equivalent to at least the highest estimated CEA worth be available for trip insertion when the shutdown margin requirement of Tech Spec 3.1.1.1 is suspended for
l t
4'
measurement of CEA worth and shutdown margin during physics tests, and boration is required when that requirement is not met. The proposed change revises LCO 3.10.1 to state that the shutdown margin and K -1 requirements of Tech Spec 3.1.1.2 may be suspended for measurement of LEA worth and shutdown margin, provided reactivity equivalent to at least the highest estimated CEA worth is available for trip insertion from operable CEAs or the reactor is subcritical by at least the reactivity equivalent of the highest CEA worth.
- 5. The proposed change adds Special Test Exception 3.10.9 to allow the facility to suspend the requirements of Tech Spec 3.1.1.1 and 3.1.1.2 for the demonstration of the operability of the control element drive mechanism system during pre-startup tests. Basis 3/4.10.9 is also added to reflect this.
- 6. As a changes result of proposed changes 1-5 above, it is necessary to propose to revise setpoints to provide reactor trips to prevent the core from exceeding its safety limits in terms of departure from nucleate boiling ratio (DNBR) and local power density. These proposed changes consist of two parts:
a~ Item B.2 of Table 2.2-1 specifies a trip setpoint for "Excore Neutron Flux Logarithmic Power Level High" of less than or equal to 0.798X of rated thermal power, and an allowable value of less than or equal to 0.815X of rated thermal power. The proposed change revises the trip setpoint and allowable value to 0.010X and 0.011X of rated thermal power, respectively.
- b. Table notation (c) of Table 3.3-1 and Table notation (5) of Table 2.2-1 state that CPC trips may be manually bypassed below 1X of rated thermal power and the bypass shall automatically be removed when thermal power is greater than or equal to 1X of rated thermal power.
The proposed changes revise the value at which the CPC trip may be manually bypassed and at which the manual bypass is automatically removed, from 1X of rated thermal power to 10 X of rated thermal power.
- 7. The proposed change renumbers Special Test Exception 3.10.9 "Natural Circulation Testing Program" (Unit 1 only) to 3.10.10. This is necessary so the Special Test Exception added in item 5 above will be the same section number in both Unit 1 and 2 Technical Specifications.
B. PURPOSE OF THE TECHNICAL SPECIFICATION The purpose of the Technical Specifications affected by these proposed changes is to ensure that an adequate shutdown margin is maintained in the reactor at all times.
C. NEED FOR THE TECHNICAL SPECIFICATION AMENDMENT This Technical Specification change will improve operational efficiency and provide ALARA benefits by reducing the amount of makeup water that must be processed during shutdown.
D. BASIS FOR PROPOSED NO SIGNIFICANT HAZARDS CONSIDERATION DETERMINATION
- 1. The commission has provided standards for determining whether a significant hazards consideration exists as stated in 10 CFR 50.92. A proposed amendment to an operating license for a facility involves no significant hazards consideration if operation of the facility in accordance with a proposed amendment would not: (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety.
A discussion of these standards as they relate to the amendment request follows:
Standard 1 Involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed changes do not involve a significant increase in the probability or consequences of an accident previously evaluated because the anticipated operational occurrences (AOOs) and accidents that have the potential for being impacted by the proposed changes have been reevaluated to determine the resulting consequences due to the proposed changes.
These AOOs and accidents are steam line break, CEA withdrawal, CEA ejection, inadvertent deboration and startup of an inactive reactor coolant pump (RCP). The results of these evaluations show that the consequences are still within the appropriate acceptance criteria discussed below.
The PVNGS safety analysis requires that steam line break events be evaluated considering potential for fuel damage. If the minimum DNBR during a steam line break event falls below specified limits based on acceptable correlations, fuel damage must be assumed. The results of the limiting steam line break analysis indicate that the minimum post-trip DNBR remains well above the specified safety limit.
The PVNGS safety analysis requires that the consequences of an uncontrolled control element assembly (CEA) withdrawal from a subcritical or low power startup condition be evaluated on the basis that they are acceptable if the minimum DNBR remains above specified limits based on acceptable correlations. The reevaluation of the limiting CEA withdrawal analysis indicates that the minimum DNBR will remain above the plant specific safety limit of 1.231.
The PVNGS safety analysis requires that for a startup of an inactive RCP, fuel clad integrity should be maintained by ensuring that specified acceptable fuel design limits are not exceeded. The results of a limiting startup of an inactive RCP indicate that the reactor remains subcritical and the specified acceptable fuel design limits are not exceeded, thus maintaining fuel clad integrity.
The PVNGS safety analysis requires that for a CEA ejection, the reactivity excursion should not result in a radially averaged enthalpy greater than 280 cal/gm at any axial location in any fuel rod. Reevaluation of the imiting CEA ejection accident concurrent with the introduction of the N-1 requirement ensures that the safety analysis acceptance criterion will be met.
The proposed change to lower the setpoint of the high logarithmic power trip will provide the trip function earlier than the previous setpoint.
This trip provides protection in the event of an inadvertent control element assembly (CEA) bank withdrawal from MODES 2 and 3 initial conditions with four reactor coolant pumps (RCPs) operating. The proposed change to lower the value of power below which the CPC trip can be bypassed and above which the manual bypass is automatically removed also provides added protection for an inadvertent CEA bank withdrawal postulated to occur in MODES 3, 4, or 5 with less than four reactor coolant pumps operating. If the reactor coolant pressure or temperature is outside the CPC wide range trip limits, a continuous reactor trip signal will be generated by all four CPC channels and an immediate reactor trip will terminate an inadvertent CEA bank withdrawal event before significant power is generated. The MODE 2 and 3, with four RCPs operating, and the MODE 3, 4, and 5, with less than four RCPs operating events have determined to be less limiting than the CEA bank withdrawal event presented in the Final Safety Analysis Report. Also, the proposed changes do not alter how the CPCs respond to design basis events.
i Therefore, operation 'of the facility in accordance with the proposed changes will not involve a significant increase in the probability or consequences of an accident previously evaluated.
Standard 2 Create the possibility of a new or different kind of accident from any accident previously evaluated.
(
The proposed changes will not create the possibility of a new"or different kind of accident from any accident previously evaluated because there is no change in the plant hardware or analysis method as a result of the proposed changes. Although some of the proposed changes will result in modification to the operating procedures and plant operation in the shutdown modes, operation of the facility in accordance with the proposed changes will not create the possibility of a new or different kind of accident from any accident previously evaluated.
Standard 3 Involve a significant reduction in a margin of safety.
Operation of the facility in accordance with the proposed changes may reduce in some way a safety margin, but where the results of the change are clearly within the acceptance criteria.
The PVNGS safety analysis requires that for an inadvertent boron dilution, a minimum time interval of 15 minutes for MODES 1 through 5 and 30 minutes for MODE 6 be available from the time an alarm makes the operator aware of unplanned boron dilution before a loss of shutdown margin occurs. The time to a complete loss of shutdown margin for the limiting inadvertent boron dilution is now 50 minutes compared to 95 minutes for the previously analyzed incident. However, an alarm will alert the operator of an unplanned boron dilution at least 15 minutes prior to a complete loss of shutdown margin.
Although a numerically smaller value of SHUTDOWN MARGIN may appear to result in a reduction in the safety margin, operation of the facility in accordance with the proposed changes does not involve a significant reduction in a margin of safety as a alarm is available in time to satisfy the safety analysis criterion.
4
The lower logarithmic power level trip setpoint and automatic removal of the CPC manual bypass at a lower power level result in an earlier reactor protective system actuation for the postulated transients, which involves no significant reduction in the margin of safety.
- 2. The proposed changes in parts 1, 3, 4, 5, and 7 match the guidance concerning the application of the standards for determining whether or not a significant hazards consideration exists (51 FR 7751) by the example:
(i) A purely administrative change to Technical Specifications : for example, a change to achieve consistency throughout the Technical Specifications, correction of an error, or a change in nomenclature.
'he proposed changes in parts 2, 3, 4, and 5 match the guidance of 51 FR 7751 by the example:
(iv) A change which either may result in some increase to the probability or consequences of a previously analyzed accident or may reduce in some way a safety margin, but where the results of the change are clearly within all acceptable criteria with respect to the system or component specifi'ed in the:Standard Review Plan; for example, a change resulting from the application of a small refinement of a previously used calculation model or design method.
The proposed changes in part 6 match the guidance of 51 FR 7751 by the example:
(ii) A change that constitutes an additional limitation, restriction or control not presently included in the technical specifications: for example, a more stringent surveillance requirement.
E. SAFETY EVALUATION FOR THE AMENDIjENT RE UEST The proposed Technical Specification amendment will not increase the probability of occurrence or the consequences of an accident or malfunction of equipment important to safety previously evaluated in the FSAR. The anticipated operational occurrences (AOOs) and accidents that have potential for being impacted by the proposed changes are steam line break, CEA withdrawal, CEA ejection, inadvertent deboration and startup of an inactive reactor coolant pump (RCP). All the impacted AOOs and accidents have been reevaluated to determine the resulting consequences due to the proposed changes. The results of these evaluations show that the consequences are appropriate acceptance criteria discussed below.
still within the
- 1. The PVNGS safety analysis requires that steam line break events be evaluated considering potential for fuel damage. If the minimum DNBR during a steam line break event falls below specified limits based on acceptable correlations, fuel damage must be assumed. The results of the limiting steam line break analysis indicate that the minimum post-trip DNBR remains well above the specified safety limit.
- 2. The PVNGS safety analysis requires that the consequences of an uncontrolled control element assembly (CEA) withdrawal from a subcritical or low power startup condition be evaluated on the basis that they are acceptable if the minimum DNBR remains above specified limits based on
acceptable correlations. The reevaluation of the limiting CEA withdrawal analysis indicates that the minimum DNBR will remain above the plant specific safety limit of 1.231.
- 3. The PVNGS safety analysis requires that for a startup or an inactive RCP, fuel clad integrity should be maintained by ensuring that specified acceptable fuel design limits are not exceeded. The result of a limiting startup of an inactive RCP indicate that the reactor remains subcritical and the specified acceptable fuel design limits are not exceeded, thus maintaining fuel clad integrity.
- 4. The PVNGS safety analysis requires that for a CEA ejection, the reactivity excursion should not result in a radially averaged enthalpy greater than 280 ca'1/gm at any axial location in any fuel rod. Reevaluation of limiting CEA ejection accident concurrent with the introduction of the K requirement ensures that the safety analysis acceptance criterion will be met.
The proposed change to lower the setpoint of the high logarithmic power trip will provide the trip function earlier than the previous setpoint. This trip provides protection in the event of an inadvertent control element assembly (CEA) bank withdrawal from MODES 2 and 3 initial conditions with four reactor
'oolant pumps (RCPs) operating. The proposed change to lower the value of power below which the CPC trip can be bypassed and above which the manual bypass is automatically removed also provides added protection for an inadvertent CEA bank withdrawal postulated to occur in MODES 3, 4, or 5 with less than four reactor coolant pumps operating. If the reactor coolant pressure or temperature is outside the CPC wide range trip limits, a continuous reactor trip signal will be generated by all four CPC channels and an immediate reactor trip will terminate an inadvertent CEA bank withdrawal event before significant power is generated. The MODE 2 and 3, with four RCPs operating, and the MODE 3, 4, and 5, with less than four RCPs operating events have been determined to be less limiting than the CEA bank withdrawal event presented in the Final Safety Analysis Report. Also, the proposed changes do not alter how the CPCs respond to design basis events.
1 Therefore, operation of the facility in accordance with the proposed changes will not involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed Technical Specification amendment will not create the possibility for an accident or malfunction of a different type than any previously evaluated in the FSAR. There is no change in the plant hardware or analysis method as a result of the proposed changes. Although some of the proposed changes will result in modification to the operating procedures and plant operation in the shutdown modes, operation of the facility in accordance with the proposed changes will not create the possibility of a new or different kind of accident from any accident previously evaluated.
Operation of the facility in accordance with the proposed changes may reduce in some way a safety margin, but where the results of the change are clearly within the acceptance criteria.
The PVNGS safety analysis requires that for an inadvertent boron dilution, a minimum time interval of 15 minutes for MODES 1 through 5 and 30 minutes for MODE 6 be available from the time an alarm makes the operator aware of unplanned boron dilution before a loss of shutdown margin occurs. The time to complete loss of shutdown margin for the limiting inadvertent boron dilution is now 50 minutes compared to 95 minutes for the previously analyzed incident.
However, an alarm will alert the operator of an unplanned boron dilution at least 15 minutes prior to a complete loss of shutdown margin.
Although a numerically smaller value of SHUTDOWN/ MARGIN may appear to result in a reduction in the safety margin, operation of the facility in accordance with the proposed changes does not involve a significant reduction in a margin of safety as an alarm is available in time to satisfy the safety analysis criterion.
The lower logarithmic power level trip setpoint and automatic removal of the CPC manual bypass at a lower power level result in an earlier reactor protective system actuation for the postulated transients, which involves no significant reduction in the margin of safety.
F. ENVIRONMENTAL IMPACT CONSIDERATION DETERMINATION The proposed change request does not involve an unreviewed environmental question because operation of PVNGS Units 1 and 2, in accordance with this change, would not:
Result in a significant increase in any adverse 1.
previously evaluated 'n the Final environmental environmental impact statement (FES) as modified by the staff's testimony to the Atomic Safety and Licensing Board, Supplements to the FES, Environmental Impact appraisals, or in any decisions of the Atomic Safety and Licensing Board; or
- 2. Result in a significant change in effluents or power levels; or
- 3. Result in matters not previously reviewed in the licensing basis for PVNGS which may have a significant environmental impact.
G.'ARKED-UP TECHNICAL SPECIFICATION CHANGE PAGES:
Index: I, II, IV, IX, X, XIV Definitions:
1-4, 1-5, 1-6, 1-7 Safety Limits and Safety Sy'tem Settings:,'-4, 2-5 Limiting Conditions for Operation and Surveillance Requirements:
3/4 1-1 1-2 1-2a 1-3 1-8 1-10 1-13 3-5 10-1 10-9 10-10 (Unit 1 only)
Bases for Limiting Conditions for Operation and Surveillance Requirements B 3/4 1-1 1-la 1-2 10-2
CD
~100 CD 75 F 50 25 100 200 300 400 50r0 TIi"lE, SECO!1DS Figure l-l
125 l
100 75 I
SO OC LL LLJ LxJ t -- t 200 300 400 500 TII'lE, SECOi'IDS Figure 1-2
~ 100 25 100 .200 300 400 TIj'lE, SECONDS
200 300 400 Sop TINE, SECOND Figure 1-17
100 0
200 300 400 500
. Trtz, sEcoHDs IU I V
"125
~-100 75 25 0
I 1 100 200 >00 500.
TIl'1E. SECONDS