R.IC3B.I EY' CCELERATED RIDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RXDS)

ACCESSXON NBR:9506190301 DOC.DATE: 95/05/31 NOTARIZED: NO DOCKET N FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power & Light Co. 05000335 50-389 St. Lucie Plant, Unit 2, Florida Power & Light Co. 05000389 AUTH-NAME AUTHOR AFFILIATION ROGERS,J.A. Florida Power & Light Co.

SAGER,D.A. Florida Power & Light Co.

RECIP.NAME RECIPXENT AFFILIATION

SUBJECT:

Monthly operating repts for May 1995 for St Lucie.W/950609 ltr.

DISTRIBUTION CODE: XE24D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-1 PD 1 1 NORRIS,J 1 1 INTERNAL: ACRS 10 10 AEOD/SPD/RRAB 1 1 ZKR CERT'1

' '~S/OECB 1 1

1 1

NRR/DISP/PIPB RGN2 1

1 1

1 EXTERNAL: LXTCO BRYCE,J H 1 1 NOAC 1 1 NRC PDR 1 1 YOTE TO ALL"RIDS" RECIPIEYTS:

PLEASE HELP US TO Rf DUCE O'ASTE! COYTACTTHE DOCL'ilfYTCONTROL DESK, ROOh I Pl-37 EXT. 504-~OS3 ) TO F LIAll.'4 %TE YOL'R i'ANIL F l<OXI DISTRIIIUTIOYLIS'I'S I'OR DOCL NIEY'I'S YOL'ON."I'L'I'.I)!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 20 ENCL 20

\~ ~

P.O. Bex 128, Ft. Pierce, FL 34954-0128 June 9, 1995 L-95-171 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Monthl 0 eratin Re ort Pursuant to Technical Specification 6.9.1.6, attached are the May, 1995, Operating Status and Summary of Operating Experience Reports for St. Lucie Units 1 and 2.

Should there be any questions on this information, please contact us.

Very truly yours, D. A. a er Vice re ident St. L e Plant DAS/PTQ cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachments 95061'F0301 950531 PDR ADQCK 05000335 R PDR an FPL Group company

l ~

~ g

~

0 k il J

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.: 50-335 UNIT: St. Lucie 51 DATE 'one 8, 1995 COMPLETED BY: Z.A.ROGERS TELEPHONE: (407) 468-4157 MONTH DAY AVERAGE DAILY POWER LEVEL (MWe -Ne t) 5/01/95 852 5/02/95 850 5/03/95 848 5/04/95 845 5/05/95 847 5/06/95 847 5/07/95 843 5/08/95 843 5/09/95 843 5/10/95 845 5/11/95 850 5/12/95 849 5/13/95 850 5/14/95 847 5/15/95 846 5/16/95 842 5/17/95 840 5/18/95 844 5/19/95 845 5/20/95 850 5/21/95 848 5/22/95 845 5/23/95 845 5/24/95 843 5/25/95 841 5/26/95 839 5/27/95 839 5/28/95 839 5/29/95 840 5/30/95 837 5/31/95 838

'T

~ ~

~

OPERATING DATA REPORT DOCKET NO 50 - 335 DATE 6/ 6/95 FPL LICENSING GROUP - JUNO TELEPHONE 407/694/4432 OPERATING STATUS

1. UNIT NAME: ST. LUCIE UNIT 1
2. REPORTIHG PERIOD: MAY 1995
3. LICENSED THERMAL POWER (MWT): 2700
4. HAMEPLATE RATING (GROSS MWE): 850
5. DESIGN ELECTRICAL RATING (NET MWE): 830
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 872
7. MAXIMUM DEPENDABLE CAPACITY (NET M'WE): 839
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)

SINCE LAST REPORT, GIVE REASONS:

~ 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)

10. REASONS FOR RESTRICTIONS, IF ANY:

MONTHLY -YTO- CUMULATIVE 11 ~ HOURS IN REPORT PERIOD: 744 3623 161663.0

12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 3403.6 126727.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0' 205.3
14. HOURS GENERATOR ON-LINE 744.0 3396.2 125353.0
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 2009143 9126312 324860053
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 661600 3025130 107175140
18. NET ELECTRICAL ENERGY GENERATED (MWH) 628354 2869636 101306539
19. UNIT SERVICE FACTOR 100.0 93.7 77.5
20. UNIT AVAILABILITYFACTOR 100.0 93.7 77.6 21..CAPACITY FACTOR (USING MDC NET) 100.7 94.4 76.9
22. CAPACITY FACTOR IOEIRG OER RETT 101.8 95.4 76.3
23. UNIT FORCED OUTAGE RATE 0.0 0.0 3.9
24. SHUTDOWNS SCHEDULED OVER HEXT 6 MONTHS :
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

F'

~

UNIT SHUTDOWNS Al'K) POWER REDUCTIONS DOCKET NO.: 50-335 UNIT NAME: ST LVCIE UNIT 1-DATE: June 8, 1995 COMPLETED BY: J.A.ROGERS TELEPHONE: (407) 468-4157 RBPORT MDNTH No. Date Type Duration (Hours)

Reason'ethod of Shutting Reactor'icenseeEvent Report System Code'omponent Code'ause & Corrective Action to Down ¹ Prevent Recurrence Unit 1 operated at full power for the entire month.

F Forced Reason Method Exhibit G - Instructions for S Scheduled A - Equipment failure (explain) I - Manual Preparation of Data Entry II - Maintenance or Test 2 - Manual Scram Sheets Licensee Event Report C - Refueling 3 - Automatic Scram (LER) File (NUREG4161)

D - Regulatory restriction 4 - Continued E - Operator Training & License Examination 5 - Load Reduction F - Administrative 9 - Other (Explain) Exhibit I - Same Source G - Operational Error (Explain)

H - Other (Explain) 09lssl FPI.

DOCKET NO.: 50-335 UNIT: St. Lucie 51 DATE: June 8, 1995 COMPLETED BY: J.A.ROGERS TELEPHONE: (407) 468-4157 Unit 1 operated at essentially full power for the entire month.

In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety .valves during the report period.

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.: 50-389 UNIT: St. Lucie g2 DATE: June 8, 1995 COMPLETED BY: J.A ROGERS TELEPHONE: (407) 468-4157 MONTH DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 5/01/95 841 5/02/95 838 5/03/95 835 5/04/95 832 5/05/95 833 5/06/95 830 5/07/95 824 5/08/95 825 5/09/95 824 5/10/95 827 5/11/95 834 5/12/95 832 5/13/95 832 5/14/95 827 5/15/95 825 5/16/95 820 5/17/95 815 5/18/95 818 5/19/95 819 5/20/95 826 5/21/95 825 5/22/95 804 5/23/95 768 5/24/95 832 5/25/95 828 5/26/95 825 5/27/95 823 5/28/95 821 5/29/95 820 5/30/95 819 5/31/95 817

I, ~ ~

OPERATING DATA REPORT DOCKET NO 50 - 389 DATE 6/ 6/95 FPL LICENSING GROUP - JUNO TELEPHOHE 407/694/4432 OPERATING STATUS

1. UNIT NAME: ST ~ LUCIE UNIT 2
2. REPORTING PERIOD: MAY 1995
3. LICENSED THERMAL POWER (MWT): 2700
4. NAHEPLATE RATING (GROSS MWE): 850
5. DESIGN ELECTRICAL RATING (NET MWE): 830
6. MAXIHUH DEPENDABLE CAPACITY (GROSS MWE): 882
7. HAXIMUM DEPENDABLE CAPACITY (NET MWE): 839
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEHS NUHBER 3 THROUGH 7)

SINCE LAST REPORT, GIVE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)
10. REASONS FOR RESTRICTIONS, IF ANY:

HOHTHLY -YTD- CUHULATIVE

11. HOURS IN REPORT PERIOD: 744 3623 103560.0
12. NUHBER OF HOURS REACTOR WAS CRITICAL 744.0 3548.4 87816.1
13. REACTOR RESERVE SHU'TDOWN HOURS 0.0 0.0 0.0
14. HOURS GENERATOR ON-L!NE 744.0 3537.1 86404.1
15. UNIT RESERVE SHU'IDOWN HOURS 0.0 0.0 0.0
16. GROSS THERHAL ENERGY GENERATED (MWH) 2003228 9468231 224665772
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 647320 3110390 74564100
18. NET ELECTRICAL ENERGY GENERATED (HWH) 612852 2944619 70450499
19. UNIT SERVICE FACTOR 100.0 97.6 83.4
20. UNIT AVAILABILITYFACTOR 100.0 97.6 83.4
21. CAPACITY FACTOR (USING MOC NET) 98.2 96.9 82.0
22. CAPACITY FACTOR (USING DER NET) 99.2 97.9 82.4
23. UNIT FORCED OUTAGE RATE 0.0 2.4 6.8
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

UNlT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.: 50-389 UNIT NAME: ST LUCIE UNIT 2 DATE: 8, 1995

'une COMPLETED BY: J.A. ROGERS TELEPHONE: (407) 468-4157 REPORT MONTH No. Date Type Duration Reason'ethod of System Component Cause & Corrective (Hours) Shutting Event Report Code4 Code Action to Reactor'icensee Down Prevent Recurrence Unit 2 operated at full power for the entire month.

F Forced Reason Method Exhibit G - Instructions for S Scheduled A - Equipment failure (explain) 1 - Manual Preparation of Data Enny B - Maintenance or Test 2 - Manual Scram Sheets Ltcensec Event Report C - Refueling 3 - Automatic Scram (LER) File (NUREG4161)

D - Regulatory restriction 4 - Continued E - Operator Training dt License Examination 5 - Load Reduction F - Administrative 9 - Other (Explain) Exhibit I - Same Source G - Operational Error (Explain)

H - Other (Explain) t61$ 87 FPl.

DOCKET NO.: 50-389 UNIT: St. Lucie 52 DATE: one 8, 1995 COMPLETED BY: Z.A.ROGERS TELEPHONE: (407) 468-4157 REPORT MONTH Unit 2 operated at essentially full power for the entire month.

In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.