MONTHYEARML24302A2402024-10-28028 October 2024 CFR 21 Report 1-BY-BC-1-LV Battery Charger IR 05000338/20240032024-10-28028 October 2024 – Integrated Inspection Report 05000338-2024003 and 05000339-2024003 ML24302A2342024-10-23023 October 2024 Request for Project Number Related to Dominion Energy Services New Nuclear Program at North Anna Power Station ML24302A1762024-10-22022 October 2024 Core Operating Limits Report Surry 2 Cycle 33 Pattern Hot Revision 0 ML24283A0392024-10-0909 October 2024 Annual Submittal of Technical Specification Bases Changes Pursuant to Technical Specification 5.5.13.D ML24281A1372024-10-0707 October 2024 ISFSI - Submittal of Cask Registration for Spent Fuel Storage ML24283A0702024-10-0707 October 2024 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J IR 05000280/20240102024-10-0202 October 2024 Biennial Problem Identification and Resolution Inspection Report 05000280/2024010 and 05000281/2024010 ML24270A0022024-09-25025 September 2024 Inservice Inspection Owners Activity Report (OAR) 05000338/LER-2024-001-01, Automatic Reactor Trip Due to Prni High Negative Rate2024-09-24024 September 2024 Automatic Reactor Trip Due to Prni High Negative Rate IR 05000338/20244202024-09-23023 September 2024 Security Baseline Inspection Report 05000338/2024420 and 05000339/2024420, Cover Letter ML24243A0872024-09-20020 September 2024 Response to EPA Comments Regarding the Final Site Specific Supplement to the Generic Eist for License Renewal North Anna Power Station, Units 1 and 2 IR 05000338/20244022024-09-17017 September 2024 Security Baseline Inspection Report 05000338/2024402 and 05000339/2024402 ML24248A1712024-09-0303 September 2024 Proposed License Amendment Request - Temporary Service Water Supply to the Component Cooling Heat Exchangers ML24215A2622024-08-28028 August 2024 Transmittal Letter for Subsequent Renewed License IR 05000338/20240052024-08-27027 August 2024 Updated Inspection Plan for North Anna Power Station, Units 1 and 2 (Report 05000338/2024005 and 05000339/2024005) IR 05000280/20240052024-08-26026 August 2024 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2024005 and 05000281-2024005), Rev 1 ML24219A2372024-08-23023 August 2024 Issuance of Amendment Nos. 319 and 319, Adoption of TSTF-577, Rev. 1, Revised Frequencies for Steam Generator Tube Inspection, ML24207A0402024-08-21021 August 2024 Summary of July 17, 2024, Public Meeting - TS 3.7/3.14 AOT for SW Piping Maintenance 05000339/LER-2024-001-01, Loss of Generator Field for 2J Eog During 2-PT-82.282024-08-20020 August 2024 Loss of Generator Field for 2J Eog During 2-PT-82.28 ML24234A0742024-08-15015 August 2024 Notification of Deviation from Pressurized Water Reactor Owners Group (PWROG) Letter OG-23-63, NEI 03-08 Needed Guidance: PWR Thermal Shield Flexure Inspection Requirements IR 05000280/20240112024-08-13013 August 2024 Comprehensive Engineering Team Inspection Report 05000280/2024011 and 05000281/2024011 ML24164A0012024-08-12012 August 2024 Proposed Alternative Relief Request V-1 Inservice Testing of Pressure Isolation Valves (EPID l-2023-LLR-0060) ML24163A3002024-08-0808 August 2024 Request for Relief Request N1-I5-NDE-007 Inservice Inspection Alternative ML24206A0052024-08-0808 August 2024 SLR Final EIS Letter to Achp ML24206A0062024-08-0808 August 2024 Notice of Availability of the Final Environmental Impact Statement for the North Anna Nuclear Power Station Unit Numbers 1 and 2 Subsequent License Renewal (Docket Numbers: 50-338 and 50-339) ML24221A1932024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Upper Mattaponi Tribe ML24221A1942024-08-0808 August 2024 Tribal Section 106 Letters-North Anna-United Keetoowah Band of Cherokee Indians in Oklahoma ML24221A1922024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Tuscarora Nation of New York ML24221A1902024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Pamunkey Indian Tribe ML24221A1892024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Nansemond Indian Nation ML24221A1912024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Rappahannock Tribe, Inc ML24221A1862024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Eastern Band of Cherokee Indians ML24221A1882024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Monacan Indian Nation ML24221A1872024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Eastern Shawnee Tribe of Oklahoma ML24221A1852024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Delaware Tribe of Indians ML24221A1842024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Delaware Nation, Oklahoma ML24221A1832024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Chickahominy Indian Tribe-Eastern Division ML24221A1822024-08-0808 August 2024 Tribal Section 106 Letters - North Anna - Chickahominy Indian Tribe ML24221A1812024-08-0808 August 2024 Tribal Section 106 Letters-North Anna - Catawba Indian Nation ML24208A0142024-08-0808 August 2024 Tribal Section 106 Letters-North Anna-Absentee-Shawnee Tribe of Indians of Oklahoma ML24241A0692024-08-0606 August 2024 ISFSI, Submittal of Cask Registration for Spent Fuel Storage IR 05000338/20240022024-08-0202 August 2024 Integrated Inspection Report 05000338/2024002 and 05000339/2024002 IR 05000280/20240022024-08-0101 August 2024 Integrated Inspection Report 05000280/2024002 and 05000281/2024002 05000280/LER-2024-001, Troubleshooting Initiated Unknown Turbine Trip Feature in Control System2024-07-30030 July 2024 Troubleshooting Initiated Unknown Turbine Trip Feature in Control System ML24206A0432024-07-26026 July 2024 Feis - Letter to the Applicant 05000338/LER-2024-001, Automatic Reactor Trip Due to Prni High Negative Rate2024-07-25025 July 2024 Automatic Reactor Trip Due to Prni High Negative Rate ML24206A0902024-07-24024 July 2024 Owners Activity Report ML24165A1232024-07-17017 July 2024 Proposed Alternative Relief Request P-1, P-2 Inservice Testing of Residual Heat and Containment Spray Pumps (EPID l-2023-LLR-0058) ML24165A2782024-07-17017 July 2024 Issuance of Amendment Nos. 318 and 318, Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection 2024-09-03
[Table view] |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 August 11, 2015 ATTN: Document Control Desk Serial No.15-387 Director, Division of Spent Fuel Storage and NLOS/TJS R0 Transportation Docket Nos. 50-338,339 Office of Nuclear Material Safety and Safeguards 50-280,281 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 License Nos. NPF-4,7 DPR-32,37 VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 SURRY POWER STATION UNITS 1 AND 2 10 CFR 71.95 REPORT - FAILURE TO OBSERVE CERTIFICATE OF COMPLIANCE
- 9168 CONDITIONS FOR THE 8-120B CASK Virginia Electric and Power Company (Dominion) is submitting this report pursuant to 10 CER 71.95(a)(3) regarding instances in which the conditions of approval in the Certificate of Compliance (CoC) #9168 for the EnergySolutions 8-120B cask were not observed when making shipments from North Anna Power Station (NAPS) and Surry Power Station (SPS).
This report is based on a 10 CFR 71.95 report notification to 8-120B cask users by the certificate holder, EnergySolutions, which Dominion received on July 21, 2015. This notification triggered the 60-day reporting requirement which is addressed by this submittal.
EnergySolutions originally reported the details of the potential failure to meet all requirements of CoC #9168, including corrective actions being taken by EnergySolutions, to the NRC by Letter CDI5-0149, dated June 24, 2015, from Daniel B. Shrum (EnergySolutions) to Mark Lombard (NRC),
Subject:
10 CFR 71.95 Report on the 8-120B Cask. [ADAMS Accession No. ML15202A058]
The enclosed notification is applicable to the past use of the 8-120B cask by Dominion facilities NAPS and SPS, Dominion records indicate that NAPS made a total of three shipments and SPS made a total of four shipments using the 8-1 20B cask. Details of these shipments are included in the attachment.
In their June 24, 2015 letter to the NRC, EnergySolutions stated there were no safety consequences from performing vent pre-shipment leak tests that may not have provided the required test sensitivity. Additionally, there will be no further tests made using the suspect gaskets since EnergySolutions has replaced all of the suspect gaskets with a modified version that does not have the potential to reduce the test sensitivity.
Serial No.15-387 Docket Nos. 50-338,339,280,281 10 CFR 71.95(a)(3) Report Page 2 of 2 If you have any questions or require additional information, please contact Mr. Thomas Szymanski at (804) 273-3065.
Sincerely, Gianna C. Clark Vice President - Nuclear Support Services
Attachment:
Dominion Shipments Using the 8-120B Cask Commitments made in this letter: None cc: Dr. V. Sreenivas NRC Project Manager - NAPS US NRC, One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Karen Cotton NRC Project Manager - SPS US NRC, One White Flint North Mail Stop 08 G-9A 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector - NAPS NRC Senior Resident Inspector - SPS EnergySolutions LLC Attn: Daniel B. Shrum / Senior Vice President Regulatory Affairs 299 South Main Street, Suite 1700 Salt Lake City, Utah 84111
Serial No.15-387 Docket No. 50-338,339,280,281 10 CFR 71.95(a)(3) Report ATTACHMENT Dominion Shipments Usinq the 8-120B Cask North Anna and Surry Power Stations Dominion
Serial No.15-387 Docket Nos. 50-338,339,280,281 10 CFR 71.95(a)(3) Report Attachment List of Dominion Shipments Using the EnergySolutions 8-120B Cask Station Destination Date of Shipment NAPS Studvic Processing Facility /Erwin, TN 04/02/20 14 NAPS Studvic Processing Facility /Erwin, TN 11/12/2014 NAPS Erwin Resin Solution / Erwin, TN 03/04/2015 SPS Studvic Processing Facility /Erwin, TN 12/04/2013 SPS Studvic Processing Facility/IErwin, TN 03/20/2014 SPS Studvic Processing Facility / Erwin, TN 11/19/2014 SPS Erwin Resin Solution / Erwin, TN 02/25/2015