ML13308A632

From kanterella
Jump to navigation Jump to search
Forwards Review of Repts on Simulation of Ground Motions
ML13308A632
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 12/06/1979
From: Bernreuter D, Tokarz F
Lawrence Livermore National Lab (LLNL)
To: Levin H
Office of Nuclear Reactor Regulation
Shared Package
ML13308A633 List:
References
TASK-03-06, TASK-3-6, TASK-RR EG-79-1, NUDOCS 7912210332
Download: ML13308A632 (2)


Text

REGULATOR"Y INFORMATION oISTRIB3UTION SYSTEM (RIDS)

ACCESSION NbR;7912210332 0OCUATE: 79/12/06 NOTARIZED: NO UOCKEIT #

'FAcIL':o-206Sa0n'Onore Nucler Station, Unit 1, SoutherCa eliforn 05000206 50-361 San Unofre Nuclear Station, Unit 2, Southern Californ 05000361 50-362 San Unofre Nuclear Station, Unit 3, Southern Calitorn 05000362 AUTH,NAME-AUTHOR AFFILIATION bERNREUTER,D,L.

Lawrence Livermore Laboratory TOKARZF.J.

Lawrence Livermore Laboratory RECIPNAME RECIPIENT AFFILIATION

LEVINM, Systematic Evaluation Program Branch

SUBJECT:

Forwards "Review of Repts on Simulation of Ground Motions,"

DISTRIBUTION CODE: A0283 COPIES RECEIVED:LTR L ENCL.L SIZE:J 1 TITLE: Seismic Revi.ew f6r SEP Plants.

NOTES RECIPIENT COPIES RECIPIENT COPIES i C000E/NAME LITk-ENCL ID CUDE/NAME LTTA ENCL ACTION:

05 BC O a

S INTERNAL: 01 02 NRC PDR 10 f

1I 1 I&E 13 GEOSCI bR 6

6 19 ENGR BR 1

1 OELD I

EXTERNAL: 03 LPDR 1

1 04 NSIC 1

1 20 ACRS 16 16 DEG 2 7 1979 TOTAL NUMBER OF COPIES REQUIRED: LTTR

-W ENCL

MW

LAWRENCE LIVWMORE LABORATORY EG-79-1 December 6, 1979 Mr. Howard Levin Systematic Evaluation Program Branch Division of Operating Reactors U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

TRANSMITTAL OF REVIEW COMMENTS ON DELTA'S REPORTS ON SIMULATION OF EARTHQUAKE GROUND MOTIONS FOR SAN ONOFRE UNIT 1.

Dear Howard:

Enclosed are my review comments or the DELTA reports. These deal in particular with DELTA's reports dated July 1979 and August 29, 1979.

The enclosed comments reflect my review of the various reports and the discussion presented at the meeting I attended with the other review panel members on September 18, 1979 in Bethesda, MD.

Please feel free to call me if you or Leon have any questions regard ing my comments or if added input is required by you or Leon.

Sincerely, Don L. Bernreuter, Leader Engineering Geosciences Group F. J. Tokarz NRC Safety Program Leader

Enclosure:

cc: D. G. Eisenhut, NRC M/S-542 L. Reiter, NRC M/S-P-314 F. J. Tokarz, L-90 G G. Zech, NRC M/S-316 File Ao?

/ //

University of California P.O. Box 808 Livermore, California 94550 1 Telephone (415) 422-1100 1 Twx 970-386-8339 UCLL LVMR