1 NRR-PMDAPEm Resource From:

Wall, Scott Sent:

Thursday, July 11, 2013 9:22 AM To:

Otto Gustafson; ERICKSON, JEFFREY S; MIKSA, JAMES P Cc:

Sheng, Simon; Parks, Benjamin; Wood, Kent; Jackson, Christopher; Chawla, Mahesh; Dion, Jeanne; Carlson, Robert

Subject:

Acceptance Review of MF2326-Updated Palisades Reactor Vessel Pressurized Thermal Shock (PTS) Evaluation By letter dated June 25, 2013, Entergy Nuclear Operations, Inc. (ENO) (the licensee) submitted an updated evaluation of PTS for Palisades Nuclear Plant (PNP). With the updated evaluation, ENO has requested approval for PNP to adjust the date on which it reaches the PTS Screening Criterion described in Title 10 of the US Code of Federal Regulations (10 CFR), part 50, section 61. The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the PTS Evaluation has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed the June 25, 2013 submittal and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed evaluation in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. You will be advised of any further information needed to support the NRC staffs detailed technical review by separate correspondence.

If you have any questions, please contact the PNP Project Manager, Mahesh Chawla, at (301) 415-8371 or myself at (301) 415-2855 Scott P. Wall, PMP, LSS BB, BSP Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

Hearing Identifier:

NRR_PMDA Email Number:

755 Mail Envelope Properties (Scott.Wall@nrc.gov20130711092100)

Subject:

Acceptance Review of MF2326-Updated Palisades Reactor Vessel Pressurized Thermal Shock (PTS) Evaluation Sent Date:

7/11/2013 9:21:47 AM Received Date:

7/11/2013 9:21:00 AM From:

Wall, Scott Created By:

Scott.Wall@nrc.gov Recipients:

"Sheng, Simon" <Simon.Sheng@nrc.gov>

Tracking Status: None "Parks, Benjamin" <Benjamin.Parks@nrc.gov>

Tracking Status: None "Wood, Kent" <Kent.Wood@nrc.gov>

Tracking Status: None "Jackson, Christopher" <Christopher.Jackson@nrc.gov>

Tracking Status: None "Chawla, Mahesh" <Mahesh.Chawla@nrc.gov>

Tracking Status: None "Dion, Jeanne" <Jeanne.Dion@nrc.gov>

Tracking Status: None "Carlson, Robert" <Robert.Carlson@nrc.gov>

Tracking Status: None "Otto Gustafson" <ogustaf@entergy.com>

Tracking Status: None "ERICKSON, JEFFREY S" <JERICKS@entergy.com>

Tracking Status: None "MIKSA, JAMES P" <jmiksa@entergy.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2061 7/11/2013 9:21:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: