ML13156A120
| ML13156A120 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 06/04/2013 |
| From: | Kalyanam N Plant Licensing Branch IV |
| To: | Pellegrin B, Williams J Entergy Operations |
| Kalyanam N | |
| References | |
| TAC MF1304 | |
| Download: ML13156A120 (2) | |
Text
1 Burkhardt, Janet From:
Kalyanam, Kaly Sent:
Tuesday, June 04, 2013 5:13 PM To:
PELLEGRIN, BRYAN J; WILLIAMS, JOE D Cc:
Burkhardt, Janet
Subject:
RAI for Waterford 3 DFS (TAC No. MF1304)
- Bryan, I am providing the formal Request for Additional Information for the subject submittal made by Entergy by letter dated March 29, 2013.
A draft copy of the RAI was provided to you May 22, 2013, and there are no changes between the 2 RAIs. In view of this, please provide your response to the RAI by June 28, 2013.
Thanks N. (Kaly) Kalyanam Plant: Waterford Steam Electric Station, Unit 3 Docket No.: 50/382 To: Bryan Pellegrin From: N. Kalyanam
Subject:
RAI for Waterford 3 DECOMMISSIONING FUNDING STATUS REPORT (TAC No.
MF1304)
TAC No.: MF1304 SUNSI Review Done: Yes.
Publicly Available, Normal Release, Non-sensitive, REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION 2013 DECOMMISSIONING FUNDING STATUS REPORT FOR ENTERGY OPERATIONS, INC.
The requests for additional information (RAIs) provided are in response to the Entergy Operations, Inc. (Entergy) 2013 Decommissioning Funding Status (DFS) report. On March 29, 2013, Entergy submitted to the U.S. Nuclear Regulatory Commission (NRC) the 2013 DFS report for Arkansas Nuclear One, Units 1 & 2, Grand Gulf Nuclear Station, River Bend Station, Unit 1 and Waterford 3 Steam Electric Station, as required under Code of Federal Regulations 10 CFR 50.75(f)(1)
Agencywide Documents Access & Management System number (ML13092A213).
RAI2: After-Tax Amounts of funds Accumulated for Waterford Steam Electric Station, Unit 3:
2 Provide the after-tax amounts of funds accumulated through December 31, 2012, for Grand Gulf Nuclear Station and Waterford 3 Steam Electric Station.
On March 29, 2013, Entergy did not state if the amounts of decommissioning funds accumulated were after-tax amounts for Grand Gulf Nuclear Station and Waterford 3 Steam Electric Station.
The provisions of 10 CFR 50.75(f)(1) and (2) require the licensee to report the amount of funds accumulated to the end of the calendar year preceding the report.