Text
Poehler, Jeffrey From:
Poehler, Jeffrey_
Sent:
Monday, January 9, 2012 7:49 AM To:
Cheruvenki, Ganesh
Subject:
RE: core plate components--Fermi Attachments:
core plate components - jcp comm 1-9-11.docx
- Ganesh, I marked up your write-up (attached). If Fermi had submitted the detailed analysis for loss of preload, would you approve the relief request? I thought the SE of BWRVIP-25 would still require the inspections even if they had done the analysis - the only way you get out of inspection is to install wedges.
Let's discuss when you get in.
Jeffrey C. Poehler Sr. Materials Engineer NRR/DE/EVIB (301) 415-8353 From: Cheruvenki, Ganesh (L.
Sent: Saturday, January 07, 20132 9:02 AM To: Poehler, Jeffrey Cc: Sheng, Simon; Chawla, Mahesh
Subject:
core plate components--Fermi
- Jeff, Here is my write-up for the core plate issue. Please review it and mark-up the copy with your comments. I will incorporate them in the SE which was already reviewed by Simon.
Mac-Jeff will be our branch chief until Thursday.
Ganesh x2501 4II