ML13008A038

From kanterella
Jump to navigation Jump to search
Near-Term Task Force Recommendation 2.3 Seismic Walkdown Report, Appendix C Area Walk-by Checklists (Awcs), #2 Battery Room. Pages 1 - 65
ML13008A038
Person / Time
Site: Beaver Valley
Issue date: 10/23/2012
From: Guerra E M, Helffrich A L
Paul C. Rizzo Associates, ABS Consulting, FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation
References
L-12-283
Download: ML13008A038 (66)


Text

APPENDIX C AREA WALK-BY CHECKLISTS (AWCs)C-1 LK-0 -' Paul C. Rizzo Associates, Inc.LNGINELUS

& CONSULTAN-, Sheet 1 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room#2 Battery Room Floor El.713 Bldg.SRVB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Y N U N/A 1. Does anchorage of equipment in the area appear to be free of X potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A 2. Does anchorage of equipment in the area appear to be free of significant X degraded conditions?

Y N U N/A 3. Based on a visual inspection from the floor, do the cable/conduit X raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y N U N/A 4. Does it appear that the area is free of potentially adverse seismic spatial x interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block walls SB 1-7 and SB 1-8 are adequate based on Calculations DSC-0086 and DSC-0087, respectively.

Block wall SB 1-10 is adequate based on calculation DSC-0089_

1.These calculations are part of aJollow-up seismic analysis in support ofiE80-1 I calculations.

All block walls in area are adequate.Related equipment on SWEL for this area: BAT- 1-2 DOD Paul C. Rizzo Associates, Inc.E'GINEERIS

& CONSULTAXTS Sheet 2 of 191 N U Area Walk-By Checklist (AWC)Status: N)Room#2 Battery Room Floor El.713 Bldg.SRVB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: 9/28/2012 Adam L. Helffrich Q -Paul C. Rizzo Associates, Inc.Sheet 3 of 191 ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Status: (W)N U Room#2 Battery Room Floor El.713 Bldg.SRVB Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-0l.jpeg

==

Description:==

General File Name: 1-60-1-4-01 .jpeg

Description:

Block wall in area I Y Paul C. Rizzo Associates, Inc.ENGINE EE & CONSULTANTS Sheet 4 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room AC Equip RM Floor El.713 Bldg.SRVB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x 7 Y N U N/A x Related equipment on SWEL for this area: VS-AC-i A-BLOWER

[X-- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 5 of 191 N U Area Walk-By Checklist (AWC)Status: (W)Room AC Equip RM Floor El.713 Bldg.SRVB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x ---T Comments (Additional pages may be added as necessary)

-4 Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helffrich 9/28/2012 L Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Sheet 6 of 191 Status: (Y)N U Room AC Equip RM Floor El.713 Bldg. SRVB Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-06jpeg

==

Description:==

General 1 lrue Name: i-oU-l-4-ob.jpeg

==

Description:==

General 2 DC Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANIS Sheet 7 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room AC Equip RM Floor El.713 Bldg.SRVB 1ile Name: 1-b6-1-4-Ub.jpeg

==

Description:==

Fire suppression system rugged flle Name: l-b0-1-4-ub.jpeg

==

Description:==

Cable trays in area full, but not overflowing LI0 I V Paul C. Rizzo Associates, Inc.EVOINEERS

& CONSULTAN"M Sheet 8 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room AT QS-TK- I Floor El.735 Bldg.YARD Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Cable lower near tank is a possible interaction.

Tower is judged to be far enough away and rugged enough to be considered not credible.Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: LT-1QS-IOOA Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 9 of 191 N U Area Walk-By Checklist (AWC)Status: W Room AT QS-TK- I Floor El.735 Bldg.YARD Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helffrich 9/28/2012

-- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTA?,1S Area Walk-By Checklist (AWC)Sheet 10 of 191 Status: (Y)N U Room Floor El.AT QS-TK-1 735 Bldg. YARD Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-(Description:

General 1 1,ile Name: l-bU-1-4-U9.jpeg

==

Description:==

General 2 I Z Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSWULTANS Sheet II of 191 Area Walk-By Checklist (AWC)Status: (Y)N U Room AT QS-TK- I Floor El.735 Bldg.YARD File Name: 1-65-1-4-09.jpeg

==

Description:==

Tower near by is judged rugged, interaction is not credible.

L[2Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 12 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room B RS PMP CUB Floor El.732 Bldg.SFGB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: RS-P-2B L-ZY% Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 13 of 191 N U Area Walk-By Checklist (AWC)Status: (Y Room B RS PMP CUB Floor El.732 Bldg.SFGB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources./bund in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x F -I Comments (Additional pages may be added as necessary)

Evaluated by: Eddie M. Guerra Date: 9/28/2012 Date: Adam L. Helffrich 9/28/2012 I Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTA-IS Area Walk-By Checklist (AWC)Sheet 14 of 191 Status: (R)N U Room B RS PMP CUB Floor El.732 Bldg. SFGB Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-10.jpeg

==

Description:==

General I2C Q Paul C. Rizzo Associates, Inc.

&L ONSULTA&TS Sheet 15 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room BAT-I ROOM Floor El.713 Bldg.SRVB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Block wall SBI -I and SBI-12 are adequate based on calculations DSC-0090 and DSC-0091, respectively.

Block wall SB I-14 is adequate based on calculation DSC-0089_2. This calculation is part of a follow-up seismic analysis in support of iE80-1 I calculations.

All block walls in area are adequate.Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: BAT-1-1 LCM Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 16 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room BAT- IROOM Floor El.713 Bldg.SRVB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: 9/28/2012 Adam L. Helffrich I Z Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTAN-T Sheet 17 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room BAT-I ROOM Floor El.713 Bldg.SRVB Other supporting or relevant documents and photos (if any): tlie Name: 1-39-1-4-1 l.jpeg

Description:

General lile Name: I-bIJ-1-4-1 l.jpeg

Description:

Block wall in area LCQ Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANnT Sheet 18 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room Blender Room Floor El.722 Bldg.AXLB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: HCV-ICH-186

'--- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSUtTANnI Sheet 19 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room Blender Room Floor El.722 Bldg.AXLB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Al/ piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x 777 -1 Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: 9/28/2012 Adam L. Helffrich a-- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTAM Sheet 20 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room Blender Room Floor El.722 Bldg.AXLB Other supporting or relevant documents and photos (if any): Hile Name: 1-M9-1-4-12jpeg

==

Description:==

General rite irame: 1-ou-i---iz.Jpeg

==

Description:==

General 2 r-v--Nn< Paul C. Rizzo Associates, Inc.Sheet 21 of 191 FNtINEttER" 6 WNULIAN-iS Area Walk-By Checklist (AWC) Status: ( N U Room Blender Room Floor El. 722 Bldg. AXLB File Name: 1-65-1-4-12.jpeg

==

Description:==

Block wall right to room entrance.

East wall File Name: 1-66-1-4-12.jpeg

==

Description:==

Block wall located front of entrance.

North wall Paul C. Rizzo Associates, Inc.ENGINEEMS

& CONSULTANMS Sheet 22 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room Boric Acid Pump Cubicle B Floor El.752 Bldg.AXLB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: CH-P-2A L Paul C. Rizzo Associates, Inc.ENGINERS & CONSULTAN-M Sheet 23 of 191 N U Area Walk-By Checklist (AWC)Status: (S)Room Boric Acid Pump Cubicle B Floor El.752 Bldg.AXLB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helffrich 9/28/2012 L Y Paul C. Rizzo Associates, Inc.ENGINEEMS

& CONSULTANTS Area Walk-By Checklist (AWC)Sheet 24 of 191 Status: W N U Room Boric Acid Pump Cubicle B Floor El.752 Bldg. AXLB Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-13.jpeg

==

Description:==

General

_1 Q -Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSUITAN-T Sheet 25 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room Boric Acid Tank IlA Floor El.752 Bldg.AXLB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

There is a small gap between one of the nut's and base on the east support post for the tank. Gap is not considered significant.

One anchor bolt is not fully engaged by half a thread on the north post of the tank. This minor thread engagement issue is judged not significant.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: CH-TK- 1A I Y Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANMS Sheet 26 of 191 Area Walk-By Checklist (AWC)Status: (S) N U Room Boric Acid Tank 1 A Floor El.752 Bldg.AXLB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

Evaluated by: Eddie M. Guerra Date: 9/28/2012 Date: Adam L. Helffrich 9/28/2012 L q4 Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 27 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room Boric Acid Tank I A Floor El.752 Bldg.AXLB Other supporting or relevant documents and photos (if any): rne Name: 1-Y)--1-4-14.jpeg

==

Description:==

General I rile Niame: I-OU-I-4-14.jpeg

==

Description:==

General 2 Q Paul C. Rizzo Associates, Inc.

& CONSULTANTS Sheet 28 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room Boric Acid Tank IlA Floor El.752 Bldg.AXLB tile Name: i-ot)-i-4-14.jpeg

==

Description:==

One anchor bolt not fully engaged on north post by halfa thread.rue iName: 1-oo-i-,4-v+.jpeg

==

Description:==

Gap between nut and base on west post C. Rizzo Associates, Inc.ENGINEERS

& CUNSULT&5TS Sheet 29 of 191 N U Area Walk-By Checklist (AWC)Status: W Room CCW Surge Tank Floor El.768 Bldg.AXLB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: CC-TK-1 LK IQ Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANnh Sheet 30 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room CCW Surge Tank Floor El.768 Bldg.AXLB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?A l piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources.found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I -I Comments (Additional pages may be added as necessary)

Eddie M. Guerra Evaluated by: Date: 9/28/2012 Date: Adam L. Helffrich 9/28/2012 Paul C. Rizzo Associates, Inc.ENGINEERS

&

Sheet 31 of 191 Area Walk-By Checklist (AWC)Status: (2)N U Room CCW Surge Tank Floor El.768 Bldg.AXLB Other supporting or relevant documents and photos (if any): rite uiNamuC 1-ov-1-q-ij.jpeg

==

Description:==

General 2 I--Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Sheet 32 of 191 N U Area Walk-By Checklist (AWC)Status: W Room Charging Pump Cubicle IC Floor El.722 Bldg.AXLB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Y N U N/A 1. Does anchorage of equipment in the area appear to be free of X potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A 2. Does anchorage of equipment in the area appear to be free of significant X degraded conditions?

Y N U N/A 3. Based on a visual inspection from the floor, do the cable/conduit X raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y N U N/A 4. Does it appear that the area is free of potentially adverse seismic spatial X interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Two valves with reach rods through the wall are on the supply piping to pump CH-P-1C. The gap at the wall penetration around each rod is approximately 1 ". The supply piping does not have lateral support and its potential movement in a seismic event could close the gap at reach rod wall penetration and cause binding. Judged acceptable, as the pipe goes through a ceiling penetration, which would provide some restraint, as well as the fact that the valves are manual valves with reach rods and that potential reach rod binding would be acceptable.

Related equipment on SWEL for this area: CH-P-IC LC--Q Paul C. Rizzo Associates, Inc.ENGINEEIRS

& CONSLLTAN"rM Sheet 33 of 191 N U Area Walk-By Checklist (AWC)Status: (9)Room Charging Pump Cubicle IC Floor El.722 Bldg.AXLB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x T 1 Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helffrich 9/28/2012 L Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSIULTAN-M Sheet 34 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room Charging Pump Cubicle 1 C Floor El.722 Bldg.AXLB Other supporting or relevant documents and photos (if any): Pile Name: 1-59-1-4-17/jpeg

==

Description:==

General riie Name: i-ou-i--1i/jpeg

==

Description:==

Pipe is not restrained in the longitudinal direction I Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Room Charging Pump Cubicle IC Floor El. 722 Bldg.Sheet 35 of 191 Status: (Y)N U AXLB Pile Name: 1-65-1-4-17.jpeg

==

Description:==

View of reach rod through wall penetration I2-- Paul C. Rizzo Associates, Inc.ENGINEERS

& COMULTANTS Sheet 36 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room Control Room Floor El.735 Bldg.SRVB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Y N U N/A 1. Does anchorage of equipment in the area appear to be free of X potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y N U N/A 2. Does anchorage of equipment in the area appear to be free of significant X degraded conditions?

Y N U N/A 3. Based on a visual inspection from the floor, do the cable/conduit X raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y N U N/A 4. Does it appear that the area is free of potentially adverse seismic spatial X interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Control room ceiling main runners are supportedfrom concrete ceiling by wires at-4' spacing. Each ceiling tile (i.e., egg grating) is tied to the main runners at each of its four corners and judged not to be a potential falling hazard. Block walls SB3-1, SB3-5, SB3-8, and SB3-9 are adequate based on calculations DSC-0095_1, DSC-0097, DSC-0 103, and DSC-O103, respectively.

These calculations are part of a follow-up seismic analysis in support of IE80-11 calculations.

Related equipment on SWEL for this area: BB-Al RK-NUC-INS-1 PNL-DC 1-3 PNL-VITBUS 1-2 PNL-VITBUS 1-3 L QPaul C. Rizzo Associates, Inc.ENGINEERS

& CONSU LTAN-T Area Walk-By Checklist (AWC)Sheet 37 of 191 N U Status: W)Room Control Room Floor El.735 Bldg.SRVB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Several fire extinguishers, chairs, tables, and trash cans in area are all unsecured, but are judged not significant interactions.

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

All adjacent panels close to each other are bolted together.Evaluated by: Date: 9/28/2012 Eddie M. Guerra ,A4 Date: Adam L. Helffrich 9/28/2012 L Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Room Control Room Sheet 38 of 191 Status: (Y)N U Floor El.735 Bldg. SRVB Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-18.jpeg

==

Description:==

General I Ile Name: l-bu-i-4-i-.jpeg

==

Description:==

Fire extinguisher near computer room I-- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTr&NT Sheet 39 of 191 N U Area Walk-By Checklist (AWC)Status: (Y Room Control Room Floor El.735 Bldg.SRVB viie Name: i-o3-i-4-i1jpeg

==

Description:==

Fire extinguisher near computer room riie Name: 1-00-1-4-18jpeg

==

Description:==

General 2 ICQ Paul C. Rizzo Associates, Inc.ENOINEERS

& CONSLTAYM Sheet 40 of 191 N U Area Walk-By Checklist (AWC)Status: (Y Room Control Room Floor El.735 Bldg.SRVB File Name: 1-67-1-4-18jpeg

==

Description:==

Block wall near computer room rue Name: t-o7-i-4-i1.jpeg

==

Description:==

Fire extinguisher near computer room Paul C. Rizzo Associates, Inc.ENGINEES & CONSaULTAN Sheet 41 of 191 Area Walk-By Checklist (AWC)Status: &N U Room Control Room Floor El.735 Bldg.SRVB File Name: 1-69-1-4-18.jpeg

==

Description:==

Several unrestrained tables, chairs, and trash cans in vicinity File Name: 1-70-1-4-18.jpeg

==

Description:==

General 3 L Y Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Room Control Room Floor El. 735 Bldg Sheet 42 of 191 Status: (Y)N U SRVB File Name: 1-71-1-4-18.jpeg

==

Description:==

Several LCD screens are secure and are not a falling concern Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANMTS Sheet 43 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room DG Room #I Floor El.735 Bldg.DGBX Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: TI-I EE-301 I QPaul C. Rizzo Associates, Inc.9N3INEERS

&

Sheet 44 of 191 N U Area Walk-By Checklist (AWC)Status: W)Room DG Room #1 Floor El.735 Bldg.DGBX Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?No ignition sources found in this area.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x T --T Comments (Additional pages may be added as necessary)

Evaluated by: Date: 9/28/2012 Eddie M. Guerra_ Date: 9/28/2012 Adam L. Helffrich I Z Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANT-Area Walk-By Checklist (AWC)Sheet 45 of 191 Status: (N)N U Room Floor El.DG Room #1 735 Bldg. DGBX Other supporting or relevant documents and photos (if any): File Name: 1-59-1-4-19.jpeg

==

Description:==

General L X Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONWULTANTS Sheet 46 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room DG Room Train A Floor El.735 Bldg.DGBX Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: 1 EE-EG- 1 EE-P-IA EE-TK-2A LS-1-EE-201-1 MCC-I-E7 MOV- 1 RW- 11 3B PNL-DGEA-1 PNL-DIGEN-1 Paul C. Rizzo Associates, Inc.ENGINEERS 4L Sheet 47 of 191 N U Area Walk-By Checklist (AWC)Status: W Room DG Room Train A Floor El.735 Bldg.DGBX Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?All piping are well supported in this area.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Fuel oil day tank and all its piping are well supported 7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Several unrestrainedfire extinguishers in the area. Since the vertical accelerations in this area are well below 1g, it is judged that these extinguishers would not dislodge from their wall supports, and therefore the interaction is not credible.8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Soot on ceiling indicates possible exhaust leak. A.[ollow up with plant personnel has revealed that the soot is caused by a downdraft that naturally occurs on the roof leading to the deposit. This is normal and judged a non issue.Comments (Additional pages may be added as necessary)

Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helffrich 9/28/2012

[CA Paul C. Rizzo Associates, Inc.ENGINEERS

&

Sheet 48 of 191 N U Area Walk-By Checklist (AWC)Status: (W)Room DG Room Train A Floor El.735 Bldg.DGBX Other supporting or relevant documents and photos (if any): Hile Name: 1-59-1-4-2

==

Description:==

General 1 rite Name: I-ou-i-4-Lu.jpeg

==

Description:==

General 2 Paul C. Rizzo Associates, Inc. Sheet 49 of 191 ENGINEERS

& CONSULTAN"S Area Walk-By Checklist (AWC)Status: (Y)N U Room DG Room Train A Floor El.735 Bldg.DGBX tile Name: 1-65-1-4-ZU.jpeg

==

Description:==

View of nearby fire extinguisher File Name: 1-66-1-4-20.jpeg

==

Description:==

View of nearby fire extinguisher L Q Paul C. Rizzo Associates, Inc.ENGINEERS

& COSULTANnS Sheet 50 of 191 N U Area Walk-By Checklist (AWC)Status: (9)Room DG Room Train A Floor El.735 Bldg.DGBX File Name: 1-67-1-4-20.jpeg

==

Description:==

View of nearby fire extinguisher viIe Name: 1-c7-l-4-zu.jpeg

==

Description:==

Soot on ceiling indicates possible exhaust leak inside building L ) Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTAN-TS Sheet 51 of 191 N U Area Walk-By Checklist (AWC)Status: T)Room DG Room Train B--East Wall Floor El.735 Bldg.DGBX Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

Spalled concrete at base of diesel generator is minor and will not reduce the capacity of the anchorage.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: MCC- I -E8 L---- Paul C. Rizzo Associates, Inc.ENGINEERS

& rCONSULTArTS Sheet 52 of 191 N U Area Walk-By Checklist (AWC)Status: (2)Room DG Room Train B--East Wall Floor El.735 Bldg.DGBX Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Fire pipe may interact with cable tray causing spray. Tracing of the line reveals the line is filled with C02, not water and is not a flooding source.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Several unrestrained fire extinguishers in room are considered not significant interactions

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Comments (Additional pages may be added as necessary)

-7 Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: Adam L. Helifrich 9/28/2012 L Y Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Room DG Room Train B--East Wall Floor El. 735 Bldg.Other supporting or rel Sheet 53 of 191 Status: &N U DGBX evant documents and photos (if any): File Name: 1-59-1-4-22.jpeg

==

Description:==

General 1 File Name: 1-60-1-4-22.jpeg

==

Description:==

General 2 LC--- Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTA2N1M Sheet 54 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room DG Room Train B--East Wall Floor El.735 Bldg.DGBX lile Name: I-Wý-I-4-22.jpeg

==

Description:==

View of nearby fire extinguisher File Name: 1-66-1-4-22.jpeg

==

Description:==

View of nearby fire extinguisher L IC Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANT' Sheet 55 of 191 Area Walk-By Checklist (AWC)Status: (Y)N U Room DG Room Train B--East Wall Floor El.735 Bldg.DGBX File Name: 1-67-l-4-22.jpeg

==

Description:==

View of nearby fire extinguisher tile Name: l-b8-l-4-22jpeg

==

Description:==

View of nearby fire extinguisher

[ qg Paul C. Rizzo Associates, Inc.ENOiNEMMIS

&

Sheet 56 of 191 N U Area Walk-By Checklist (AWC)Status: (w)Room DG Room Train B--East Wall Floor El.735 Bldg.DGBX File Name: 1-69-1-4-22.jpeg

==

Description:==

Minor spalling underneath diesel generator File Name: 1-70-l-4-22.jpeg

==

Description:==

Fire pipe in proximity of cable tray, is a co2 line L Q Paul C. Rizzo Associates, Inc.ENGINEERS

& WM ULTA.N*Th Sheet 57 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room East Cable Vault Floor El.735 Bldg.SFGB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: MCC-I-E12 MCC-1-E6 TRS-BIP-PNL 1

LX"j Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTrS Sheet 58 of 191 N U Area Walk-By Checklist (AWC)Status: W Room East Cable Vault Floor El.735 Bldg.SFGB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Fire protection pipe above TRS BIP PNL 1 judged to be rigidly supported.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Unrestrainedfire extinguishers and a poorly secured ladder in area are considered not significant.

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

A mostly rod hung cable tray (with minimal lateral supports) has a gap of about 4" to MCC-1-E6 and MCC-1-E12.

It is judged that the available gap is adequate to preclude interaction of the tray with these MCC's.Y N U N/A x Y N U N/A x Y N U N/A x Y N U x I I I Evaluated by: Date: 9/28/2012 Eddie M. Guerra Date: 9/28/2012 Adam L. Helffrich I Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTAN M Sheet 59 of 191 N U Area Walk-By Checklist (AWC)Status: (Y Room East Cable Vault Floor El.735 Bldg.SFGB Other supporting or relevant documents and photos (if any): ltle Name: 1-39-1-4-23.jpeg

==

Description:==

General 1 File Name: 1-60-1-4-23.jpeg

==

Description:==

General 2 I Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTANTS Area Walk-By Checklist (AWC)Room East Cable Vault Floor El. 735 Bldg.Sheet 60 of 191 Status: ()N U SFGB File Name: 1-65-1-4-23.jpeg

==

Description:==

Fire pipe over panel is rigidly supported File Name: 1-67-1-4-23.jpeg

==

Description:==

Fire extinguisher and loose ladder in area X Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSIULTItUS Area Walk-By Checklist (AWC)Room East Cable Vault Floor El. 735 Bldg.Sheet 61 of 191 Status: ()N U SFGB tile Name: 1-015-1-4-L-.jpeg

==

Description:==

Fire extinguisher in area L Y Paul C. Rizzo Associates, Inc.

& CONSULTAN-S Sheet 62 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room Emer Swgr Room Train A Floor El.713 Bldg.SRVB Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

INV-VITBUS I panel has a gap of 1" to a wall. It is judged that this gap is adequate and there will be no impact to the wall. HVAC grill over INV-Vitbusl-3 is held with small screws, but appears to be rugged, it is not a credible fall hazard. Block wall SB I-11 and SB 1-12 are adequate under calculation DSC-0090 and DSC-0091, respectively.

Block wall SB I-15 is adequate under calculation DSC-0093.

These calculations are part of a follow-up seismic analysis in support of lE80-11 calculations.

Y N U N/A x Y N U N/A x Y N U N/A x Y N U N/A x Related equipment on SWEL for this area: BAT-CHG-3 PNL-AC I-El BAT-CHG- 1 SAF-SW-65 480VUS- 1-8-N TRANS- 1-8N 4KVS-lAE TRF-1015 DC-SWBD1-1 DC-SWBDI-3 DC-SWBD 1-4 1NV-VITBUS 1-1 INV-VITBUS 1-3

[ Y Paul C. Rizzo Associates, Inc.ENGINEERS

&

Sheet 63 of 191 N U Area Walk-By Checklist (AWC)Status: (Y)Room Emer Swgr Room Train A Floor El.713 Bldg.SRVB Interaction Effects 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?Danger fire sign posted on battery room door. Batteries are well restrained and no potential interaction or falling of objects that could short the battery terminals and cause afire were found Judged adequate.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Several unrestrained fire extinguishers in area are judged not significant.

8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

In general, all cabinets appear to be bolted together if within proximity of another cabinet Y N U N/A X Y N U N/A X Y N U N/A X Y N U x F-T Evaluated by: Date: 9/28/2012 Eddie M. GuerraDate: 9/28/2012 Adam L. Helffrich I Q Paul C. Rizzo Associates, Inc.ENGINEERS

& CONSULTAN-S Sheet 64 of 191 N U Area Walk-By Checklist (AWC)Status: (w)Room Floor El.Emer Swgr Room Train A 713 Bldg.SRVB Other supporting or relevant documents and photos (if any): Vlle Name: 1-M9-1-4-25.Jpeg

==

Description:==

General I rue Niame: i-ou-i-Q-Lz.jpeg

==

Description:==

General 2 Paul C. Rizzo Associates, Inc.EININEERS f COMUAN-S Sheet 65 of 191 N U Area Walk-By Checklist (AWC)Status: ()Room Emer Swgr Room Train A Floor El.713 Bldg.SRVB File Name: 1-65-1-4-25.jpeg

==

Description:==

Block wall and unrestrained fire extinguisher in area.File Name: 1-66-1-4-25.jpeg

==

Description:==

View of nearby fire extinguisher