EQ-QR-33-WBT-NP, Rev. 0, Wbt DMINS-DX Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2
ML11322A102
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 11/14/2011
From: Jurcevich N
Westinghouse
To:
Office of Nuclear Reactor Regulation
References
EQ-QR-33-WBT-NP, Rev. 0
Download: ML11322A102 (98)


Text

Attachment 7 Non-proprietary Westinghouse Electric Company document EQ-QR-33-WBT-NP, Revision 0, "WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2," (non-proprietary) dated October 2011 (Letter Item 7)

O Westinghouse Westinghouse Non-Proprietary Class 3 WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 EQ-QR-33-WBT-NP, Rev. 0 October 2011 APPROVALS Function Name and Signature Author Natalie R. Jurcevich*

Principal Engineer, Equipment Qualification I Verifier John J. Zotter*

Principal Engineer, Equipment Qualification II Approver Gary G. Ament*

Manager, Equipment Qualification I

  • Electronically approved records are authenticated in the electronic document management system.

WESTINGHOUSE NON-PROPRIETARY CLASS 3

© 2011 Westinghouse Electric Company LLC All Rights Reserved

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXT'l) for Watts Bar Unit 2 WBT DMIMS-DXTM LIST OF CONTRIBUTORS Revision Name and Title 0

Jenna L. Tyger Technical Editor, Technical Communications 0-NP S. B. Brown, Engineering Technician, Equipment Qualification II Template Version 2.2 EQ-QR-33-WBT-NP, Rev. 0 i

Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM REVISION HISTORY RECORD OF CHANGES Revision Author Description Completed A

Stanley G. Cheyne Preliminary Issue 9/09 0

Stanley G. Cheyne The purpose of this revision is to incorporate the 4/10 finalized seismic test documentation and drawing revisions.

0-NP Natalie R. Jurcevich Revision 0-NP is Revision 0 with proprietary content See EDMS removed.

DOCUMENT TRACEABILITY & COMPLIANCE Created to Support the Following Document(s)

Document Number Revision N/A OPEN ITEMS Item Description Status None.

EQ-QR-33-WBT-NP, Rev. 0 ii Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTm Monitoring System (DMIMS-DX Tm) for Watts Bar Unit 2 TABLE OF CONTENTS Section Title Page LIST O F CO N TRIBU TO R S.......................................................................................

i R E V ISIO N H ISTO R Y................................................................................................

ii TA B L E O F C O N TEN T S..............................................................................................

iii LIST O F T A B LE S..................................................................................................

v L IST O F FIG U R E S.....................................................................................................

v ACRONYMS AND TRADEMARKS.........................................................................

viii G LO SSARY O F TERM S.......................................................................................

ix R EFER EN C ES....................................................................................................

x SECTION 1 INTRODUCTION AND BACKGROUND................................................................

1-1 SECTION 2 DMIMS-DX SYSTEM FOR WATTS BAR UNIT 2..................................................

2-1 2.1 CONFIGURATION OF THE DMIMS-DX SYSTEM FOR WATTS BAR U N IT 2.........................................................................................................................

2 -1 2.2 SEISM IC REQU IREM EN TS......................................................................................

2-3 2.2.1 D M IM S-D X System [

2-3 2.2.2 DMIMS-DX [

]a" Components.........................................................

2-10 SECTION 3 SEISMIC TESTING PERFORMED...........................................................................

3-1 3.1 D M IM S-D X SY STEM [

1a'........................................................................

3-1 3.1.1 Configuration of the DMIMS-DX Seismically Tested System [

]a,c............... 3-1 3.1.2 Seism ic R equirem ents..................................................................................................

3-1 3.2 DMIMS-DX SYSTEM [

]a,c COMPONENTS.......................... 3-9 3.2.1 Configuration of the [

]"c Components Tested..................................

3-9 3.2.2 Seism ic R equirem ents..................................................................................................

3-9 3.3 SUPPLEMENTAL DMIMS-DX SYSTEM COMPONENT TESTING..................... 3-16 3.3.1 Configuration of the Supplemental Components Tested.............................................

3-16 3.3.2 Seism ic R equirem ents..................................................................................................

3-16 SECTION 4 SEISMIC EVALUATION PERFORMED............................

4-1 4.1 D M IM S-D X SY STEM []a, 4-1 4.1.1 DMIMS-DX System [

],c Analysis.........................

4-I 4.1.2 Comparison of Seismic Requirements.........................................................................

4-1 4.1.3 Evaluation of DMIMS-DX System [

]a3,............................ 4-7 4.1.4 Evaluation of DMIMS-DX System [

]a'c.............................. 4-7 4.1.5 Evaluation of DMIMS-DX System [

]ac..............................................

4 -7 4.1.6 Evaluation of [

]"c DMIMS-DX System [

]ac.......................... 4-8 EQ-QR-33-WBT-NP, Rev. 0 iii Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 4.2 DMIMS-DX [

]fc COMPONENTS..........................................

4-8 4.2.1 Com parison of Seism ic Requirem ents.........................................................................

4-8 4.2.2 Mounting Requirements [

]a-C...........................................

4-14 4.2.3 Mounting Requirements [

]PC...................................................

4-14 4.3 EVALUATION OF SUPPLEMENTAL DMIMS-DX SYSTEM CO M PO N EN T TESTIN G...........................................................................................

4-14 4.3.1 Comparison of Seismic Requirem ents.........................................................................

4-14 SEC TIO N 5 SU M M A R Y.................................................................................................................

5-1 5.1 D M IM S-D X SY STEM

]a,c........................................................................

5-1 5.2 DMIMS-DX [

]aC COMPONENTS..........................................

5-1 5.3 SUPPLEMENTAL DMIMS-DX SYSTEM COMPONENT TESTING..................... 5-1 EQ-QR-33-"T-NP, Rev. 0 iv Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 TABLE OF CONTENTS (cont.)

LIST OF TABLES Table Table2.1-1. [

Table 2.1-2. [

Table 3.2-1.

Table 4.1-1. [

Figure Figure 2.2-1. I Figure 2.2-2. I Figure 2.2-3. I Figure 2.2-4. I Figure 2.2-5. I Figure 2.2-6. I Figure 2.2-7. I Figure 2.2-8.

Figure 2.2-9. I Figure 2.2-10.

Figure 2.2-11.

Figure 2.2-12.

Figure 2.2-13.

Figure 2.2-14.

Figure 2.2-15.

Title Page

................... 2-1

..................... 2-2

]a,c.......................................................................................................... 3 -9

]a~c................................................................................................

4 -1 LIST OF FIGURES Title Page

]ac............................................................... 2 -4

]3,C.............................................................. 2 -5

]ac............................................................... 2 -6

]*'c...............................................................

2 -7

]a,............................................................... 2 -8

]a,.............................................................. 2 -9

......................................................................................................... 2 - 1 1

]a.c..........................................................................................................

2 -12

....... 2-13

]a...

............................................. 2 -14

]a,..........................................................................................................

2 -15

]a,c..........................................................................................................

2 -16

]ac.......................................................................................................... 2 -17 2 -18 1a;....... 2-19 I

I II I

II I

EQ-QR-33-WBT-NP, Rev. 0 v

Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 V

Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ¶ for Watts Bar Unit 2 WBT DMIMS-DXTM Figure 2.2-16. [

Figure 2.2-17. [

Figure 2.2-18. [

Figure 2.2-19. [

Figure 2.2-20. [

Figure 2.2-21. [

Figure 2.2-22. [

Figure 2.2-23. [

Figure 2.2-24. [

Figure 2.2-25. [

Figure 2.2-26. [

Figure 2.2-27. [

Figure 2.2-28. [

Figure 2.2-29. [

Figure 2.2-30. [

Figure 2.2-31. [

Figure 2.2-32. [

Figure 2.2-33. [

Figure 2.2-34. [

Figure 2.2-35. [

Figure 2.2-36. [

Figure 3.1-1. [

Figure 3.1-2. [

]fla............................................................................................................

2 -2 0

]ac........................................................................................................... 2 -2 1

] a,....... 2-22

]a,c............................................................................................................ 2 -2 3

]3O C..........................................

2 -2 4

]ac............................................................................................................ 2 -2 5

]1c........................................................................................................... 2 -2 6

]a"............................................................................................................ 2 -2 7

]al........................................................................

2 -2 8

]t c.................................................................... 2 -2 9

]f 'c....................................................................

2 -3 0

]ac.................................................................... 2 -3 1

]ac.................................................................... 2 -3 2

]ac....................................................................

2 -3 3

]ac.................................................................... 2 -3 4

]ac.................................................................... 2 -3 5

]a,c.................................................................... 2 -3 6

]ac................................................................... 2 -3 7 P C....................................................................

2 -3 8

]a,c.................................................................... 2 -3 9

]a*c.................................................................... 2 -4 0

],bC.................................................................................... 3 -3

]abc...................................................................................................... 3 -4 EQ-QR-33-WBT-NP, Rev. 0 Ai Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Wafts Bar Unit 2 WBT DMIMS Figure 3.1-3.

Figure 3.1-4.

Figure 3.1-5.

Figure 3.1-6.

Figure 3.2-1.

Figure 3.2-2.

Figure 3.2-3.

Figure 3.2-4.

Figure 3.2-5.

Figure 3.2-6.

Figure 3.3-1.

Figure 3.3-2.

Figure 3.3-3.

Figure 3.3-4.

Figure 3.3-5.

Figure 3.3-6.

Figure 4. 1-1.

Figure 4.1-2.

Figure 4.1-3.

Figure 4.1-4.

Figure 4.2-1.

Figure 4.2-2.

Figure 4.2-3.

Figure 4.2-4.

Figure 4.3-1.

Figure 4.3-2.

Figure 4.3-3.

Figure 4.3-4.

EQ-QR-33-W

.DXTM I

]a,b,c.......................

d.............................................................................. 3 -5 abc...........

........................................................... 3-7

]a~b~c.......................................................................................3-8

[

]a,b,c....................................................................................................... 3 -10 abc...................................................................... 3-1 1

]a,b,c.......................................................................................................

3 -12 F

]a,b

~c 3 -13

]a,b,c....................................................................................................... 3 -14

]a~b~c

......3-15

[

]a,b,c.......................................................................................................

3 -17 F

iabc.................................................................................

3-18

]a~bx.......................................................................................................

3-19

]a~bc.........................................................................................

3-20

[

]a,b,c.......................................................................................................

3-21

]a,b~c.......... 3-22 Sa~b~c..............................4-3 jab,c................................. 4-4

[]f~b~c 4-5 II]ab~c 4-6

[

]a,b,c..........................................................................................................

4 -10

] ~

a.b..........................................................................................................

4 -18

]

...................... 4-1 a,b,c....................

................................................... 4-13 I

..b..

........... 4-12

[

[.].,b,c.

............. 4-13

]a.b,c.................................... 4-18

[aIc

........................................ 4-19 BT-NP, Rev. 0 vii Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM ACRONYMS AND TRADEMARKS Acronyms used in the document are defined in WNA-PS-00016-GEN, "Standard Acronyms and Definitions" (Reference 23), or included below to ensure unambiguous understanding of their use within this document.

Acronym Definition DLF DMIMS-DXTM EDMS EQLR F-B FRS ft g

Hz IEEE IERS mA msec NRC OBE oz P/N RRS s

SCSI S/N S-S sec SG SSE TRS TVA V

WBT ZPA Dynamic Loading Factor Digital Metal Impact Monitoring System Electronic Document Management System Equipment Qualification Lab Report Front-to-Back Floor Response Spectra Feet Acceleration of gravity Hertz Institute of Electrical and Electronics Engineers, Inc.

In-Equipment Response Spectra milliamp millisecond Nuclear Regulatory Commission Operating Basis Earthquake Ounce Part Number Required Response Spectra Seconds Small Computer System Interface Serial Number Side-to-Side Seconds Steam Generator Safe Shutdown Earthquake Test Response Spectra Tennessee Valley Authority Vertical Watts Bar Unit 2 Zero Period Acceleration DMIMS-DXTM is a registered trademark of Westinghouse Electric Company, LLC.

All other product and corporate names used in this document may be trademarks or registered trademarks of other companies, and are used only for explanation and to the owners' benefit, without intent to infringe.

EQ-QR-33-WBT-NP, Rev. 0 viii Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DX TM GLOSSARY OF TERMS Standard terms used in the document are defined in WNA-PS-00016-GEN, "Standard Acronyms and Definitions" (Reference 23), or included below to ensure unambiguous understanding of their use within this document.

Term Definition None.

EQ-QR-33-WBT-NP, Rev. 0 ix Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ¶ for Watts Bar Unit 2 WBT DMIMS-DX TM REFERENCES Following is a list of references used throughout this document.

1.

Regulatory Guide 1.133, Rev. 1, "Loose-Part Detection Program for the Primary System of Light-Water-Cooled Reactors," U.S. Nuclear Regulatory Commission, May 1981.

2.

IEEE Standard 344-1987, "IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations," Institute of Electrical and Electronics Engineers, Inc., June 1987.

3.

[

4.

]tc

"]a,c 5.

6.

[C

]ac

7.

[

]a,c

8.

IEEE Standard 344-1975, "IEEE Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations," Institute of Electrical and Electronics Engineers, Inc., December 1974.

9.

1 lac

10.

[

11.

12.

]ac

]a,c EQ-QR-33-WBT-NP, Rev. 0 x

Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 X

Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX TM REFERENCES (cont.)

13.

[

14.

[

pac 15.

16.

]a 17.

18.

]

19.

[],c

]a,c

20.

[

]ac

21.

Avallone, Eugene A. and Theodore Baumeister I1, "Marks' Standard Handbook for Mechanical Engineers," Tenth Edition, New York, McGraw-Hill, 1996.

,C a,C

22.

IEEE Standard 323-1983, "IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations," Institute of Electrical and Electronics Engineers, Inc., June 1983.

23.

WNA-PS-00016-GEN, Rev. 4, "Standard Acronyms and Definitions," Westinghouse Electric Company LLC.

(Last Page of Front Matter)

EQ-QR-33-WBT-NP, Rev. 0 xi Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DX TM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 SECTION 1 INTRODUCTION AND BACKGROUND This report demonstrates that the Westinghouse Digital Metal Impact Monitoring System (DMIMS)-

DXTM System being provided to Watts Bar Unit 2 (WBT) as part of the WBT Completion Project [

]" meets the seismic requirements specified in U.S. Nuclear Regulatory Commission (NRC) Regulatory Guide 1.133, "Loose-Part Detection Program for the Primary System of Light-Cooled Reactors" (Reference 1), and maintains structural integrity in accordance with the requirements of the Institute of Electrical and Electronics Engineers, Incorporated (IEEE)

Standard 344-1987, "IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations" (Reference 2), when subjected to the WBT-specific operating basis earthquake (OBE) and safe shutdown earthquake (SSE) seismic events. Regulatory Guide 1.133 (Reference 1) requires that components of the loose parts detection system in the primary system should be designed and installed to perform their functions following all seismic events that do not require plant shutdown. Recording equipment need not function without maintenance following the specific seismic event, provided the audio and visual alarm capability remains functional.

The WBT DMIMS-DX System is seismically qualified [

]a,c in accordance with IEEE Standard 344-1987 (Reference 2).

]a,c In addition to seismic qualification of the WBT DMIMS-DX System

]',c the structural integrity of the WBT DMIMS-DX System [

]aC is evaluated pac Specific details of the seismic evaluations performed for the WBT DMIMS-DX System are documented herein.

Revision 0 of this document also incorporates customer comments on the preliminary version (Revision A)

]ac EQ-QR-33-WBT-NP, Rev. 0 1-1 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ¶ for Watts Bar Unit 2 WBT DMIMS-DXTM Note that the seismic qualification testing of the DMIMS-DX System was performed to IEEE Standard 344-1987 (Reference 2), however, [

]ac,, WBT is committed to IEEE Standard 344-1975, "IEEE Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations" (Reference 8). The qualification testing performed to support the qualification of DMIMS-DX, as documented herein, bounds the requirements specified in IEEE Standard 344-1975 (Reference 8).

(Last Page of Section 1)

EQ-QR-33-WBT-NP, Rev. 0 1-2 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX TM SECTION 2 DMIMS-DX SYSTEM FOR WATTS BAR UNIT 2 2.1 CONFIGURATION OF THE DMIMS-DX SYSTEM FOR WATTS BAR UNIT 2 The DMIMS-DX System provided to WBT is defined in Iac Table 2.1-1. 1 Ia,c ac EQ-QR-33-WBT-NP, Rev. 0 2-1 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM a~c 1

2 Table 2.1-2. [

Iac axc EQ-QR-33-WBT-NP, Rev. 0 2-2 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX TM a,c 2.2 SEISMIC REQUIREMENTS 2.2.1 DMIMS-DX System I

]a'C As per letter (

]"', the WBT DMIMS-DX System [

]"' will be located in [

]a.

The OBE and SSE required response spectra (RRS)

]a.x follow in Figures 2.2-1 through 2.2-6.

Figures 2.2-1 through 2.2-6 contain hand drawn markups, with corresponding hand notated revision bars.

These markings were on the original transmission of input data [

]a,C, EQ-QR-33-WBT-NP, Rev. 0 2-3 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-3 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ¶ for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-1. 1 I a.c EQ-QR-33-WBT-NP, Rev. 0 2-4 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DX T¶ for Watts Bar Unit 2 a,c Figure 2.2-2. 1 SaC EQ-QR-33-WBT-NP, Rev. 0 2-5 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-5 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 WBT DMIMS-DX TM a,c Figure 2.2-3. 1 I a,c EQ-QR-33-WBT-NP, Rev. 0 2-6 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,c Figure 2.2-4. 1 2a,c EQ-QR-33-WBT-NP, Rev. 0 2-7 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-7 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX Tn for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-5. [

I a,c EQ-QR-33-WBT-NP, Rev. 0 2-8 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,c Figure 2.2-6. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-9 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-9 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DX TM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 2.2.2 DMIMS-DX [

Ia,c Components Per drawing [

]ac, the DMIMS-DX [

]ac are located [

]ac The OBE and SSE RRS [

DMIMS-DX [

RRS for the DMIMS-DX ac are defined in [

]ac The OBE and SSE RRS for the

]a'c at WBT are shown in Figures 2.2-7 through 2.2-24. The OBE and SSE

]a,c are shown in Figures 2.2-25 through 2.2-36.

Figures 2.2-7 through 2.2-36 contain hand drawn markups, while some also contain corresponding hand notated revision bars. These markings were on the original transmission of input data

]ac.

EQ-QR-33-WBT-NP, Rev. 0 2-10 Westinghouse Non-Proprietary Class 3

WET DMIMS-DXTrm Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,c Figure 2.2-7. [

I a,c EQ-QR-33-WBT-NP, Rev. 0 2-11 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-11 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTm a,c Figure 2.2-8. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-12 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-12 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitorin2 System (DMIMS-DX T M~)

for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-9. 1 I a,c EQ-QR-33-WBT-NP, Rev. 0 2-13 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-13 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX TM a,c Figure 2.2-10. 1 I a,c EQ-QR-33-WBT-NP, Rev. 0 2-14 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-14 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-11. 1 I a4c EQ-QR-33-WBT-NP, Rev. 0 2-15 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-12. 1 ia,c EQ-QR-33-WBT-NP, Rev. 0 2-16 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-13. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-17 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-17 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,c Figure 2.2-14. [

Sas, EQ-QR-33-WBT-NP, Rev. 9 2-18 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-18 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM*) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-15. 1 I ac EQ-QR-33-WBT-NP, Rev. 0 2-19 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-19 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXT M

a,c Figure 2.2-16. 1 1

2,C EQ-QR-33-WBT-NP, Rev. 0 2-20 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-17. 1

] a,c EQ-QR-33-WBT-NP, Rev. 0 2-21 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXrm Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ) for Watts Bar Unit 2 a,c Figure 2.2-18. [

I a,c EQ-QR-33-WBT-NP, Rev. 9 2-22 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-22 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-19. [

Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-23 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-23 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXT¶ for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-20. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-24 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-24 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-21. [

I a,c EQýQR-33-WBT-NP, Rev. 0 2-25 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TNI) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-22. [

Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-26 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 a,c Figure 2.2-23. 1 I a.c EQ-QR-33-WBT-NP, Rev. 0 2-27 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-27 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T ) for Watts Bar Unit 2 a,c Figure 2.2-24. 1 2a,c EQ-QR-33-WBT-NP, Rev. 0 2-28 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-28 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-25. 1 I a,c EQ-QR-33-WBT-NP, Rev. 0 2-29 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,c Figure 2.2-26. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-30 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-30 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TMl) for Watts Bar Unit 2 a,c Figure 2.2-27. [

2a,C EQ-QR-33-WBT-NP, Rev. 0 2-31 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-31 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM ac Figure 2.2-28. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-32 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX-rM a,c Figure 2.2-29. 1 EQ-QR-33-WBT-NP, Rev. 0 2-33 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-33 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX Tm) for Watts Bar Unit 2 a,c Figure 2.2-30. 1 Ia,c EQ-QR-33-WBT-NP, Rev. 0 2-34 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-34 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXFM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,c Figure 2.2-31. 1 Sa.c EQ-QR-33-WBT-NP, Rev. 0 2-35 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T¶ for Watts Bar Unit 2 a,c Figure 2.2-32. [

I ac EQ-QR-33-WBT-NP, Rev. 0 2-36 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-36 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,c Figure 2.2-33. 1 I 2,C EQ-QR-33-WBT-NP, Rev. 0 2-37 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-37 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXrM a,c Figure 2.2-34. [

I a,c EQ-QR-33-WBT-NP, Rev. 0 2-38 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DX TM a,c Figure 2.2-35. 1 I a.c EQ-QR-33-WBT-NP, Rev. 0 2-39 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 2-39 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 WBT DMIMS-DXTM a,c Figure 2.2-36. [

2 a,c (Last Page of Section 2)

EQ-QR-33-WBT-NP, Rev. 0 2-40 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DX TM SECTION 3 SEISMIC TESTING PERFORMED Seismic testing was performed to qualify the DMIMS-DX System Seismic testing of the DMIMS-DX System [

]a.c.

]aC was performed in May 2008, the results of which are documented in [

].*.

Seismic testing of the DMIMS-DX System

] components was performed in May 2004 and is documented in [

]ac Supplemental seismic testing was also performed

]a,.

This supplemental seismic testing was performed in October 2009 and is documented in [

3ac.

The seismic testing was performed to show that the DMIMS-DX System meets the seismic requirements of U.S. NRC Regulatory Guide 1.133 (Reference 1) and that the system maintains structural integrity in accordance with the requirements of IEEE Standard 344-1987 (Reference 2).

3.1 DMIMS-DX SYSTEM [

I alc 3.1.1 Configuration of the DMIMS-DX Seismically Tested System [

I aC The configuration of the DMIMS-DX System II

]a*c that was subjected to seismic testing is defined

]a,c 3.1.2 Seismic Requirements Figures 3.1-1 through 3.1-3 show the OBE Test Response Spectra (TRS) versus the RRS

]ax in the front-to-back, side-to-side, and vertical directions, respectively,

]*x seismic testing documented in [

]a..

Figures 3.1-4 through 3.1-6 show the SSE TRS versus the RRS [

]a, in the front-to-back, side-to-side, and vertical directions, respectively, [

]ax seismic testing documented in

]a,c II

]a,c EQ-QR-33-WBT-NP, Rev. 0 3-1 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM I

]a~c EQ-QR-33-WBT-NP, Rev. 0 3-2 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-2 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 WBT DMIMS-DXrm a,b,c Figure 3.1-1. 1 I]a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-3 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,b,c Figure 3.1-2. 1 I a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-4 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,b,c Figure 3.1-3. 1 I a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-5 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-5 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX Tm) for Watts Bar Unit 2 a,b,c Figure 3.1-4. 1 Ia,b,c EQ-QR-33-WBT-NP, Rev. 0 3-6 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 a,b,c Figure 3.1-5. [

I a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-7 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-7 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM*) for Watts Bar Unit 2 a,b,c Figure 3.1-6. [

I a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-8 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-8 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DX TM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 3.2 DMIMS-DX SYSTEM[

3.2.1 Configuration of the Table 3.2-1 lists the DMIMS-DX a,c.

Table 3.2-1. 1

]ac COMPONENTS

]SC Components Tested

]c components tested jax ac

+

+

  • 1*

+

3.2.2 Seismic Requirements Figures 3.2-1 through Figure 3.2-3 show the OBE TRS versus the RRS of the [

]3,C in the front-to-back, side-to-side, and vertical directions, respectively, from the seismic testing documented in [

]jax. Figures 3.2-4 through Figure 3.2-6 show the SSE TRS versus the RRS of the [

a,c in the front-to-back, side-to-side, and vertical directions, respectively, from the seismic testing documented

]a,c As shown by Figures 3.2-1 through 3.2-6, the RRS used []c were enveloped by the TRS in all test runs in all directions and include the 10% margin recommended by IEEE Standard 323-1983 (Reference 22).

EQ-QR-33-WBT-NP, Rev. 0 3-9 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTN¶) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 3.2-1. [

]a,b.c EQ-QR-33-WBT-NP, Rev. 0 3-10 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-10 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DX TM abc a,b,c7 Figure 3.2-2. [

EQ-QR-33-WBT-NP, Rev. 0 3-11 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-11 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXrM Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,b,c7 Figure 3.2-3. 1

] a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-12 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DX TM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,b,c Figure 3.2-4. [

I a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-13 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-13 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM abc a,b,cI Figure 3.2-5. [

]a,b,c EQýQR-33-WBT-NP, Rev. 0 3-14 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 3.2-6. 1

,a,b,c EQ-QR-33-WBT-NP, Rev. 0 3-15 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM 3.3 SUPPLEMENTAL DMIMS-DX SYSTEM COMPONENT TESTING 3.3.1 Configuration of the Supplemental Components Tested Certain DMIMS-DX [

]ax components identified in [

, were not included in the [

a test program and functionality could not be shown by analysis. Therefore, those certain components were seismically qualified in a separate test program. The results of that test program are documented in [

]a,c Therefore, the [

was seismically qualified and shown to meet the requirements of U.S. NRC Regulatory Guide 1.133 (Reference 1) and IEEE Standard 344-1987 (Reference 2) as documented in [

]a.c.

3.3.2 Seismic Requirements Figures 3.3-1 through 3.3-3 show the OBE TRS versus the RRS of the [

]a,c in the front-to-back, side-to-side, and vertical directions, respectively, from the seismic testing documented

]C. Figures 3.3-4 through 3.3-6 show the SSE TRS versus the RRS of the

[]a, in the front-to-back, side-to-side, and vertical directions, respectively, from the seismic testing documented in axc As shown by Figures 3.3-1 through Figures 3.3-6, the RRS used enveloped by the TRS in all test runs in all directions.

]a,, were EQ-QR-33-WBT-NP, Rev. 0 3-16 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-16 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 a,b,c Figure 3.3-1. [

I a.b.c EQ-QR-33-WBT-NP, Rev. 0 3-17 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-17 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM ) for Watts Bar Unit 2 A L a,oc Figure 3.3-2. [

la,b,e EQ-QR-33-WBT-NP, Rev. 0 3-18 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-18 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 a,b,c Figure 3.3-3. 1 Ia,bc EQ-QR-33-WBT-NP, Rev. 0 3-19 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 3-19 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 3.3-4. [

la,b,c EQ-QR-33-WBT-NP, Rev. 0 3-20 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTNI) for Watts Bar Unit 2 WBT DMIMS-DXTM a,bc Figure 3.3-5. [

la,b,c EQ-QR-33-WBT-NP, Rev. 0 3-21 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM ) for Watts Bar Unit 2 a,b,c Figure 3.3-6. 1 I a,b,c (Last Page of Section 3)

EQ-QR-33-WBT-NP, Rev. 0 3-22 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DX TM SECTION 4 SEISMIC EVALUATION PERFORMED 4.1 DMIMS-DX SYSTEM I Ia,c To demonstrate that the DMIMS-DX System [

1IC meets the seismic requirements of U.S. NRC Regulatory Guide 1.133 (Reference 1) and maintains structural integrity in accordance with the requirements of IEEE Standard 344-1987 (Reference 2), an analysis was performed to show that the WBT DMIMS-DX System [

],C was

[ "c to the DMIMS-DX [

]ac discussed in subsection 3.1.1.

a~c 4.1.1 DMIMS-DX System I I a,c Analysis I

I a,c The [

],c analysis is documented [

]a,c. The results of the completed evaluation demonstrate that the DMIMS-DX System [

]" meet the seismic and functionality requirements specified in U.S. NRC Regulatory Guide 1.133 (Reference 1) and maintain structural integrity in accordance with IEEE Standard 344-1987 (Reference 2) when subjected to the WBT OBE and SSE RRS shown in subsection 2.2.1 at 5% critical damping.

]a,c Table 4.1-1. 1 I a,c a,c I

4.1.2 Comparison of Seismic Requirements To show that the results of the testing documented in [

],C are applicable to the WBT location and that the WBT DMIMS-DX System [

]a, can be seismically qualified [

]", it is necessary to show that the WBT OBE and SSE RRS documented in Reference 13 EQ-QR-33-WBT-NP, Rev. 0 4-1 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 I

subsection 2.2.1 are enveloped by the subsection 3.1.2.

]a-c and presented in

]ac OBE and SSE RRS presented in Figure 4.1-1 and Figure 4.1-2 show that the WBT OBE RRS of Reference 13 are enveloped [

]ac OBE RRS while Figure 4.1-3 and Figure 4.1-4 show that the WBT SSE RRS of Reference 13 are enveloped by the [

]ax' SSE RRS.

EQ-QR-33-WBT-NP, Rev. 0 4-2 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 4.1-1. 1

]a~b,c EQ-QR-33-WBT-NP, Rev. 0 4-3 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2abc Figure 4.1-2. 1 a,b,c EQ-QR-33-WBT-NP, Rev. 0 4-4 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-4 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DX TM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM ) for Watts Bar Unit 2 a,b,c Figure 4.1-3. 1 Ila,b~c EQ-QR-33-WBT-NP, Rev. 0 4-5 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-5 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXTM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 'a,b,c Figure 4.1-4. 1 1a,b,c EQ-QR-33-WBT-NP, Rev. 0 4-6 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-6 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 WBT DMIMS-DXTM 4.1.3 Evaluation of DMIMS-DX System [

la,C I

Ia,c 4.1.4 Evaluation of DMIMS-DX System [

[

4.1.5 Evaluation of DMIMS-DX System [

a~c I a,c Ia,c EQ-QR-33-WBT-NP, Rev. 0 4-7 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-7 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T¶ for Watts Bar Unit 2 WBT DMIMS-DX TM I

]a,c 4.1.6 Evaluation of I 1ac DMIMS-DX System I a,c Since the WBT DMIMS-DX System [

1", will be installed [

seismically qualify this [

]a,, configuration. To verify that the integrity when subjected to the WBT SSE RRS defined in Reference 13 [

]a.c, the [

calculated [

it was necessary to

]a,C will maintain structural

]aC was pac By showing that the [

] WBT DMIMS-DX System

[

]a,, the [

]a,c WBT DMIMS-DX System [

]aC will be certain to maintain structural integrity when subjected to the WBT SSE RRS defined in Reference 13

]a,c.

4.2 DMIMS-DX I

]a,c COMPONENTS II

]ac 4.2.1 Comparison of Seismic Requirements As shown in Figures 2.2-7 through 2.2-36, [

]ac, all RRS were shown at 2% Critical Damping. The data from these figures were digitized and enveloping OBE and SSE RRS for all principal directions at 2% Critical Damping were determined.

EQ-QR-33-WBT-NP, Rev. 0 4-8 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM Pac The resulting OBE and SSE envelope RRS at 2% Critical Damping for WBT and are shown in Figures 4.2-1 and 4.2.-2.

]a~c As shown in Figure 4.2-3 and Figure 4.2-4, [

],,c RRS completely envelopes the WBT RRS from Reference 15 [

]a,c. Note that the comparisons shown in Figures 4.2-1 through 4.2-4 do not include an additional 10% margin as recommended by IEEE 323-1983, "IEEE Standard for Qualifying Class IE Equipment for Nuclear Power Generating Stations" (Reference 22); however, as stated in subsection 3.3.2, 10% margin was included in Figures 3.2-1 through 3.2-6.

EQ-QR-33-WBT-NP, Rev. 0 4-9 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-9 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTNI) for Watts Bar Unit 2 WBT DMIMS-DXrM a,b,c Figure 4.2-1. [

I absc EQ-QR-33-WBT-NP, Rev. 0 4-10 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXT"M) for Watts Bar Unit 2

.WBT DMIMS-DX TM a,b,c Figure 4.2-2. 1 Ia,b,c EQ-QR-33-WBT-NP, Rev. 0 4-11 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-11 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 4.2-3. 1 Ila,b,c Figure 4.2-3.

abc EQ-QR-33-WBT-NP, Rev. 0 4-12 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-12 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 4.2-4. 1 Ia,b.c EQ-QR-33-WBT-NP, Rev. 0 4-13 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DX T-) for Watts Bar Unit 2 WBT DMIMS-DX TM 4.2.2 Mounting Requirements [

I 2ac pac The mounting configuration at the WBT plant should replicate this configuration. If this mounting configuration [

]a., is not possible, an evaluation will need to be performed showing that the mounting configuration selected meets the structural integrity requirements of IEEE Standard 344-1987 (Reference 2) when subjected to the SSE at the mounting location.

4.2.3 Mounting Requirements [

I a'c

]a,c The mounting configuration at the WBT plant should replicate this configuration. If this mounting configuration [

]axc is not possible, an evaluation will need to be performed showing that the mounting configuration selected meets the structural integrity requirements of IEEE Standard 344-1987 (Reference 2) when subjected to the SSE at the mounting location.

4.3 EVALUATION OF SUPPLEMENTAL DMIMS-DX SYSTEM COMPONENT TESTING The configuration of the supplemental components tested is described in subsection 3.3.1. The following section compares the WBT seismic requirements defined in subsection 2.2.1 to the seismic requirements for the supplemental component testing performed in the [

]apc as defined in subsection 3.3.2.

4.3.1 Comparison of Seismic Requirements

]a,c To show that the WBT requirements are met, the WBT FRS will be compared to the RRS used in the [

]a,c testing of [

]a,,, showing that the WBT FRS is enveloped by the [

]a.x RRS will show that the seismic requirements for WBT were met during the EQ-QR-33-WBT-NP, Rev. 0 4-14 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DX TM) for Watts Bar Unit 2 supplemental DMIMS-DX

]a,c

]aC Components testing documented in [

Figures 4.3-1 and 4.3-2 show that the WBT OBE RRS of Reference 13 are enveloped by the [

]a,, OBE RRS. Figures 4.3-3 and 4.3-4 show that the WBT SSE RRS of Reference 13 are enveloped by the [

]ac SSE RRS.

EQ-QR-33-WBT-NP, Rev. 0 4-15 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXrM Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 a,b,c Figure 4.3-1. 1 la,b,c EQ-QR-33-WBT-NP, Rev. 0 4-16 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-16 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTm) for Watts Bar Unit 2 WBT DMIMS-DXTM a,b,c Figure 4.3-2. [

I a,b,c EQ-QR-33-WBT-NP, Rev. 0 4-17 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-17 Westinghouse Non-Proprietary Class 3

WBT DMIMS-DXT M Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTm) for Watts Bar Unit 2 a,b,c Figure 4.3-3. 1

]a,b,c EQ-QR-33-WBT-NP, Rev. 0 4-18 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-18 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact WBT DMIMS-DXTM Monitoring System (DMIMS-DX TM ) for Watts Bar Unit 2 a,b,c Figure 4.3-4. [

Ila,b,c (Last Page of Section 4)

EQ-QR-33-WBT-NP, Rev. 0 4-19 Westinghouse Non-Proprietary Class 3 EQ-QR-33-WBT-NP, Rev. 0 4-19 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DXTM SECTION 5

SUMMARY

5.1 DMIMS-DX SYSTEM [

Ia,c

[

]ac The WBT OBE and SSE RRS of Reference 13 for [

] c was shown to be enveloped by the seismic testing documented in

]a,c, as illustrated in Figures 4.1-1 through 4.1-4.

]a,c It was also shown that the [

]a, DMIMS-DX System when subject to the SSE RRS of Reference 13 for

]ax.

]a,c will maintain structural integrity In summary, the seismic testing and analysis documented herein for the WBT DMIMS-DX System I

]a,, is qualified for the Watts Bar Unit 2 application in accordance with U.S. NRC Regulatory Guide 1.133 (Reference 1) and IEEE Standard 344-1987 (Reference 2) when subjected to the Watts Bar Unit 2 OBE and SSE seismic events as defined in Reference 13 for a,c 5.2 DMIMS-DX I

]a,c COMPONENTS The completed evaluation of the seismic qualification of the WBT DMIMS-DX [

]a"C and summarized herein shows that the components listed in Table 2.1-2 are qualified for the Watts Bar Unit 2 application in accordance with U.S. NRC Regulatory Guide 1.133 (Reference 1) and IEEE Standard 344-1987 (Reference 2) when subjected to the Watts Bar Unit 2 OBE and SSE seismic events as defined in Reference 15.

Mounting requirements [

subsections 4.2.2 and 4.2.3, respectively.

]a, are defined in 5.3 SUPPLEMENTAL DMIMS-DX SYSTEM COMPONENT TESTING Supplemental testing of various DMIMS-DX [

]afc components was performed. The seismic test configuration is discussed in subsection 3.3.1, while the seismic requirements used during the EQ-QR-33-WBT-NP, Rev. 0 5-1 Westinghouse Non-Proprietary Class 3

Seismic Evaluation of the Digital Metal Impact Monitoring System (DMIMS-DXTM) for Watts Bar Unit 2 WBT DMIMS-DX TM test program are shown in subsection 3.3.2. Section 4.3 includes a discussion of the applicability of this testing to the WBT application a,c.

Based upon the comparison of WBT requirements and test data, the supplemental testing of the DMIMS-DX [

]a,C supports the qualification of the WBT DMIMS-DX System

]ac in accordance with U.S. NRC Regulatory Guide 1.133 (Reference 1) and IEEE Standard 344-1987 (Reference 2) for the WBT application.

(Last Page of Section 5)

EQ-QR-33-WBT-NP, Rev. 0 5-2 Westinghouse Non-Proprietary Class 3