It Duke JAMES R. MORRIS Vice President FdEnergy Duke Energy Catawba Nuclear Station 4800 Concord Rd.
York, SC 29745 803- 701-4251 June 15, 2011 803-701-3221 fax U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001
SUBJECT:
Duke Energy Carolinas, LLC Catawba Nuclear Station Units 1 and 2 Docket Nos.: 50-413 and 50-414 Emergency Response Data System (ERDS) Data Point Library Revision Please revise the Catawba Emergency Response Data System (ERDS) Data Point Library (DPL) to reflect the following changes:
- 1. Revised instrument ranges due to a modification associated with the Catawba Nuclear Station (CNS) Unit 1 Nuclear Instrumentation Source Range and Intermediate Range equipment.
- 2. Revised the point IDfor three meteorological points on CNS Unit 1 to reflect that these points are scanned directly by the CNS Unit 1 plant computer instead of being data linked from CNS Unit 2.
- 3. A new point for meteorological stability classification was added to the Data Point Library on both Catawba Units.
The Attachments provide the details of these changes. Fields containing changed data from the existing Data Point Library are highlighted.
This revision is being submitted in accordance with 10CFR50, Appendix E, Section VI, 3a.
If there are any questions, please contact Rainer Blessing at (803) 701-3857 or Ronnie Miller at (803) 701-3804.
Very truly yo rs, JCes R. Morris Attachments: 1. Highlighted Changes to Catawba Unit 1 ERDS Data Point Library
- 2. Highlighted Changes to Catawba Unit 2 ERDS Data Point Library 110(L www. duke-energy.corn
U. S. Nuclear Regulatory Commission June 15, 2011 Page 2 xc: (with attachments)
V.M. McCree, Regional Administrator U.S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, GA 30303-1257 xc: (w/o attachments)
J. H. Thompson NRC Project Manager (CNS)
U.S. Nuclear Regulatory Commission Mail Stop 8 G9A Washington, DC 20555-0001 G.A. Hutto III Senior Resident Inspector (CNS)
U.S. Nuclear Regulatory Commission
Attachment 1: Highlighted Changes to Catawba Unit 1 ERDS Data Point Library Catawba Unint1: Catawba Unit 1.- Catawba Unit 1:
POINT ID CIA0766 CIA0767 NRC ERDS PARAMETER NIINTERRNG NI INTER RNGx PLANT SPEC POINT DESC N-35 INTERMEDIATE RANGE LEVEL N-36 INTERMEDIATE RANGE LEVEL GENERIC/COND DESC NUCLEAR INSTRUMENTS, INTER RANGE NUCLEAR INSTRUMENTS, INTER RANGE CRITICAL SAFETY FUNCTION RX RX ANALOG/DIGITAL (A or D) A A ENGR UNITS/DIG STATE % %
ENGR UNITS CONVERSION N/A N/A MINIMUM INSTR RANGE 1.OOE-08 1.OOE-08 MAXIMUM INSTR RANGE 2.OOE+02 2.OOE+02 ZERO POINT REFERENCE N/A N/A REFERENCE POINT NOTES N/A N/A PROC OR SENS (P or S) S S NUMBER OF SENSORS 1 1 HOW PROCESSED N/A N/A SENSOR LOCATIONS CORE BASKET AT 0 DEG CORE BASKET AT 180 DEG ALARM/TRIP SETPOINTS 25% - HIGH 25% - HIGH NI DETECTOR PWR SUPPLY CUT N/A N/A OFF NI DETECTOR PWR SUPPLY CUT N/A N/A ON INSTRUMENT FAILURE MODE LOW LOW TEMPERATURE COMPENSATION Y Y LEVEL REFERENCE LEG N/A N/A UNIQUE SYSTEM DESCR N/A N/A 4
Attachment 1: Highlighted Changes to Catawba Unit 1 ERDS Data Point Library C rba Unit I., 1Cntmwha Unit 1 Ir-staha tinit I.
POINT ID CIA1500 CIA1506 NRC ERDS PARAMETER NI SOURC RNG NISOURCRNGx PLANT SPEC POINT DESC SOURCE RANGE LEVEL CHANNEL 1 SOURCE RANGE LEVEL CHANNEL 2 GENERIC/COND DESC NUCLEAR INSTRUMENTS SOURCE RANGE NUCLEAR INSTRUMENTS SOURCE RANGE CRITICAL SAFETY FUNCTION RX RX ANALOG/DIGITAL (A or D) A A ENGR UNITS/DIG STATE CPS CPS ENGR UNITS CONVERSION N/A N/A MINIMUM INSTR RANGE 1.00E-01 1.00E-01 MAXIMUM INSTR RANGE 1.OOE+06 1.OOE+06 ZERO POINT REFERENCE N/A N/A REFERENCE POINT NOTES N/A N/A PROC OR SENS (P or S) S S NUMBER OF SENSORS 1 1 HOW PROCESSED N/A N/A SENSOR LOCATIONS CORE BASKET AT 0 DEG CORE BASKET AT 180 DEG ALARM/TRIP SETPOINTS 1E5 - HIGH 1E5 - HIGH NI DETECTOR PWR SUPPLY CUT N/A N/A OFF NI DETECTOR PWR SUPPLY CUT N/A N/A ON INSTRUMENT FAILURE MODE LOW LOW TEMPERATURE COMPENSATION Y Y LEVEL REFERENCE LEG N/A N/A UNIQUE SYSTEM DESCR N/A N/A 5
Attachment 1: Highlighted Changes to Catawba Unit 1 ERDS Data Point Library Catanwhm []Ed* 1 Cnfawha Hudt I- Ctmuhn Unit I-POINT ID C1 P0254 Cl P0250 NRC ERDS PARAMETER STAB CLASS1 WIND DIR1 PLANT SPEC POINT DESC AMB AIR D/T ELE 660 & 827 15 MIN RUN AVG UPPER WIND DIRECTION 15 MIN RUN AVG GENERIC/COND DESC AIR STABILITY AT REACTOR SITE WIND DIRECT AT THE REACTOR SITE CRITICAL SAFETY FUNCTION MISC MISC ANALOG/DIGITAL (A or D) A A ENGR UNITS/DIG STATE DEGC DEG ENGR UNITS CONVERSION N/A N/A MINIMUM INSTR RANGE -4 0 MAXIMUM INSTR RANGE 8 540 ZERO POINT REFERENCE N/A NIA REFERENCE POINT NOTES N/A N/A PROC OR SENS (P or S) P P NUMBER OF SENSORS 2 1 HOW PROCESSED 15 MIN RUNING AVG 15 MIN RUNING AVG SENSOR LOCATIONS METEOROLOGICAL TOWER METEOROLOGICAL TOWER ALARM/TRIP SETPOINTS N/A N/A NI DETECTOR PWR SUPPLY CUT N/A N/A OFF NI DETECTOR PWR SUPPLY CUT N/A N/A ON INSTRUMENT FAILURE MODE LOW LOW TEMPERATURE COMPENSATION Y Y LEVEL REFERENCE LEG N/A N/A UNIQUE SYSTEM DESCR DELTA TEMP BETWEEN UPPER AND LOWER DIRECTION WIND IS COMING FROM TEMP'S 6
Attachment 1: Highlighted Changes to Catawba Unit 1 ERDS Data Point Library POINT ID CIP0251 NRC ERDS PARAMETER WIND SPEEDI PLANT SPEC POINT DESC UPPER WINDSPEED 15 MIN RUN AVG GENERIC/COND DESC WIND SPEED AT THE REACTOR SITE CRITICAL SAFETY FUNCTION MISC ANALOG/DIGITAL (A or D) A ENGR UNITS/DIG STATE MPH ENGR UNITS CONVERSION N/A MINIMUM INSTR RANGE 0 MAXIMUM INSTR RANGE 90 ZERO POINT REFERENCE N/A REFERENCE POINT NOTES N/A PROC OR SENS (P or S) P NUMBER OF SENSORS 1 HOW PROCESSED 15 MIN RUNNING AVG SENSOR LOCATIONS METEOROLOGICAL TOWER ALARM/TRIP SETPOINTS N/A NI DETECTOR PWR SUPPLY CUT N/A OFF NI DETECTOR PWR SUPPLY CUT N/A ON INSTRUMENT FAILURE MODE LOW TEMPERATURE COMPENSATION Y LEVEL REFERENCE LEG N/A UNIQUE SYSTEM DESCR 7
Attachment 1: Highlighted Changes to Catawba Unit 1 ERDS Data Point Library rj iu.a1u NRC ERDS PARAMETER STABCLASSIx PLANT SPEC POINT DESC STABILITY CL (1=A, 2=B, C=3, 4=D, 5=E, 6=F, 7=G)
GENERIC/COND DESC AIR STABILITY AT REACTOR SITE CRITICAL SAFETY FUNCTION MISC ANALOG/DIGITAL (A or D) A ENGR UNITS/DIG STATE N/A ENGR UNITS CONVERSION N/A MINIMUM INSTR RANGE 1 MAXIMUM INSTR RANGE 7 ZERO POINT REFERENCE N/A REFERENCE POINT NOTES N/A PROC OR SENS (P or S) S NUMBER OF SENSORS 1 HOW PROCESSED N/A SENSOR LOCATIONS METEOROLOGICAL TOWER ALARM/TRIP SETPOINTS N/A NI DETECTOR PWR SUPPLY CUT N/A OFF NI DETECTOR PWR SUPPLY CUT N/A ON INSTRUMENT FAILURE MODE LOW TEMPERATURE COMPENSATION Y LEVEL REFERENCE LEG N/A UNIQUE SYSTEM DESCR N/A 8
Attachment 2: Highlighted Changes to Catawba Unit 2 ERDS Data Point Library I ---- C*Awba UWM__,,__
POINT ID C215067 NRC ERDS PARAMETER STABCLASSix PLANT SPEC POINT DESC STABILITY CL (I=A, 2=B, C=3, 4=D, 5=E, 6=F, 7=G)
GENERIC/COND DESC AIR STABILITY AT REACTOR SITE CRITICAL SAFETY FUNCTION MISC ANALOG/DIGITAL (A or D) A ENGR UNITS/DIG STATE N/A ENGR UNITS CONVERSION N/A MINIMUM INSTR RANGE 1 MAXIMUM INSTR RANGE 7 ZERO POINT REFERENCE N/A REFERENCE POINT NOTES N/A PROC OR SENS (P or S) S NUMBER OF SENSORS 1 HOW PROCESSED N/A SENSOR LOCATIONS METEOROLOGICAL TOWER ALARM/TRIP SETPOINTS N/A NI DETECTOR PWR SUPPLY CUT N/A OFF NI DETECTOR PWR SUPPLY CUT N/A ON INSTRUMENT FAILURE MODE LOW TEMPERATURE COMPENSATION Y LEVEL REFERENCE LEG N/A UNIQUE SYSTEM DESCR N/A 9