SEntergy Indian Point Energy Center Status Report July 5, 2006 Operational Status IP2 is currently at 100% reactor power; the unit has been on line for s9 days and Unit 3 is operating at 100% reactor power and has been on-line for t65 days.
Groundwater Investigation Entergy has received sample data from monitoring wells located south and west of Unit 1. These wells were tested as part of the groundwater investigation into the extent of contamination at Indian Point.
ID Dept Location Date Sr-90 Tritium h
Results Results
,____(pCi/L)
(pCi/L)
MW-107 Southeast of Unit 1 6/6/06 ND MW-44 Near Unit 3 FSB 5/24/06 ND 237 MW-46 South of Unit 3 5/24/06 ND 623 MW-U3-1 Near Unit 3 Turbine Building 3/16/06 1.0 763 MW-U3-2 Near Unit 3 Turbine Building 3/16/06 ND 282 MW-U3-3 Near Unit 3 Turbine Building 3/16/06 ND 263 MW -U3-5/26/06 1900 T2 Unit 3 Turbine Building 1.2 MW-U3-T1 Unit 3 Turbine Building 5/26/06 1.3 732 MW-39 Southwest of Unit 1 5/30/06 2.4 307 MW-41 41' Southwest of Unit 1 5/25/06 4.3 607 63' 4.5 MW-43 28' South of IP3 Tank 5/25/06 1.8 ND 62 ND ND MW-44 48' Southwest of Unit 1 3/28/06 ND 338 MW-45 42.5' Southwest of Unit 1 5/25/06 1.6 1820
_ 61' 1.2 1710 These sample results are consistent with previously reported Entergy results and are consistent with Unit 1 being the source of Sr-90 in groundwater although additional water sampling and other analysis techniques such as soil samples will be done to further evaluate the results above. Entergy is also conducting a review of previous contamination events in these areas and historic use of the areas as a possible cause for the presence of strontium 90.
-Enlergy, Unit 1 Demineralizer System Entergy has been utilizing an enhanced dimineralizer system in the Unit 1 spent fuel pool to lower the concentration of Strontium-90 in the pool. Since March 2006 the overall concentration of Sr-90 in the Unit 1 pool has decreased by about 77%.
Educational Outreach Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civic organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would like a brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.
If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.