AmerenUE Callaway Plant PO Box 620 Fulton, MO 65251 May 8, 2006 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 ULNRC05286 WAmereil#
UE Ladies and Gentlemen:
DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
FACILITY OPERATING LICENSE NPF-30 Correction to Callaway Plant PART 21 Notification Regarding PRIME Measurement Products Pressure Transmitters Issued under ULNRC05243
References:
ULNRC05243: PART 21 Notification - PRIME Measurement Products Models 763 & 763A Pressure Transmitters and Model 764 Differential Pressure Transmitters, dated December 16, 2005. NRC ADAMS Accession Number ML053620368 Nuclear Industry Advisory from PRIME Measurement Products, dated November 2, 2005. NRC ADAMS Accession Number ML053180299 Union Electric letter ULNRC05243 dated December 16, 2005, transmitted the final Part 21 notification for Callaway Plant related to a Nuclear Industry Advisory from PRIME Measurement Products which identified concerns with commercial Zener diodes installed on some Model 763 and 763A pressure transmitters and Model 764 differential pressure transmitters.
This correspondence is issued to correct certain details discussed in ULNRC05243 regarding the number of affected transmitters issued to Callaway Plant.
-Te/ q a subsidiary of Ameren Corporation
- ^ s ULNRC05286 May 8, 2006 Page 2 Based on information provided by the Nuclear Industry Advisory from PRIME Measurement Products dated November 2, 2005, ULNRC05243 stated, "SGT LLC purchased 22 of the suspect transmitters for use in the Callaway Plant Steam Generator replacement project. Six additional suspect transmitters had been supplied directly to Callaway Plant." The Advisory included a table of affected transmitters and recipients showing 22 transmitters provided to SGT Ltd. (Callaway) and six transmitters provided to Union Electric (Callaway).
Callaway Plant did receive the indicated six transmitters; however, only 20 transmitters were actually issued to SGT LLC for the Callaway steam generator replacement project. Two of the transmitters, S/N 5564 and S/N 5565, were incorrectly identified as having been provided to SGT LLC.
The PRIME Nuclear Industry Advisory lists transmitter S/N 5564 twice, showing the transmitter issued to both Alabama Power (Farley) and, incorrectly, to SGT Ltd.
(Callaway). Required notification to the appropriate recipient, Alabama Power (Farley), was accomplished by the original PRIME Nuclear Industry Advisory.
Transmitter S/N 5565 was originally supplied by PRIME to Westinghouse. This fact is documented in Westinghouse's NSAL 06-3 letter regarding recipients of affected transmitters supplied by Westinghouse. NSAL 06-3, Table 1, provides a list of affected transmitters. The first transmitter listed is S/N 5565 with Watts Bar as the recipient. Table 1 includes a footnote for S/N 5565 stating, "This transmitter was provided by Westinghouse; however it is erroneously listed under 'SGT Ltd.
(Callaway)' in the attached PRIME Nuclear Industry Advisory." Required notification to Watts Bar was accomplished by Westinghouse's NSAL 06-3 letter.
Subsequent communications with PRIME Measurement Products confirmed these errors in the original PRIME Industry Advisory. Enclosed is a copy of the formal acknowledgment received from PRIME Measurement Products via facsimile on May 4, 2006.
Callaway Plant received 26 potentially affected transmitters, of which, 21 were determined to contain commercial Zener diodes. All affected transmitters received by Callaway have been properly dispositioned. The remaining details provided under ULNRC05243 are unchanged.
ULNRC05286 May 8,2006 Page 3 If you have any questions, please contact Mr. David R. Waller at 573/676-8595.
This letter does not contain new commitments.
Sincerely, th D. YoGIg 0
Manager, Regulatory Affairs JWH/slk Enclosure
e rs ULNRC05286 May 8, 2006 Page 4 Mr. Bruce S. Mallett Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Jack N. Donohew (2 copies)
Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O-7D1 Washington, DC 20555-2738 Missouri Public Service Commission Governor Office Building 200 Madison Street PO Box 360 Jefferson City, MO 65102-0360 Records Center Institute of Nuclear Power Operations 700 Galleria Parkway Atlanta, GA 30339 Mark Larson Manager Nuclear & Government Product Engineering 900 S. Turnbull Canyon Road City of Industry, CA 91745
5-4-06; S:18PM;Garton Instrument
- 626 961 44bZ 1/
Measurement Products May 4, 2006 Mr. Kip Barbour Ameren CallawayNuclear Power Plant Voice: (573) 6764342 FAX: (573) 676-4334
SUBJECT:
PRTME Nuclear Industry Notification dated Nov. 5, 2005 Total Number of Pages Faxed: 1 The subject notification on the Barton Model 763, 763A and 764 transmitter Zener diode issue included a listing of transmitters of concern that included two errors. Both of these errors impact the listing of transmitters that are supplied for use at the Callaway nuclear power plant. The errors and their resolution are:
I. Model 764 S/N 5564 is listed as being provided to both SGT Ltd. And Alabama Power. The listing of this transmitter for SGT Ltd. was a typographical error. Because Alabama Power was notified of the issue associated with transmitter 764-5564 no frnther action is required.
- 2. Model 764 S/N 5565 listed as being provided to SGT Ltd. The listing of this transmitter for SGT Ltd.
was also a typographical error. Transmitter 764-5565 was supplied to Westinghouse and they have been notified of this situation. Westinghouse has included transmitter 764-5565 in their notification made to their customers.
Please do not hesitate to contact me if we can be of further assistance.
Best Regards, Mark Larson Manager, Nuclear & Government Product Engineering Prime Measurement Products, LLC (Formnerly Barton Instrument Systems, LLC)
Phone: (626) 961-2547 ext. 228 FAX: (626) 937-0493 E-mail: mlarson(avrime-measurement.com 1