Radiological Environmental Monitoring Program (REMP) for the Point Beach Nuclear Plant Two Rivers, Wisconsin
ML061290226
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 02/08/2005
From: Grob B
Environmental
To:
Office of Nuclear Reactor Regulation
References
8006, FOIA/PA-2010-0209
Download: ML061290226 (64)


Text

APPENDIX I

Environmental, Inc. Midwest Laboratory Final Report for the Point Beach Nuclear Plant Reporting Period: January - December 2005

Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road

  • Northbrook, IL 60062-2310 (847) 564-0700 tax (847) 564-4517 FINAL REPORT TO WISCONSIN ELECTRIC POWER COMPANY MILWAUKEE, WISCONSIN RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

FOR THE POINT BEACH NUCLEAR PLANT TWO RIVERS, WISCONSIN PREPARED AND SUBMITTED BY ENVIRONMENTAL INCORPORATED MIDWEST LABORATORY Project.Number: 8006 Reporting Period: January-December, 2005 Reviewed and Approved by_

Date 02- °8 -20Ocg Distribution:

K. Johansen

Section POINT BEACH NUCLEAR PLANT TABLE OF CONTENTS Page List of Tables.................................

iii INTRODUCTION.................................

1I LISTING OF MISSED SAMPLES..................

2...............2 1.0 2.0 Appendices A

B C

D Interlaboratory Comparison Program Results........................... A-1 Data Reporting Conventions........

........................ B-1 Sampling Program and Locations............

.................... C-1 Graphs of Data Trends................................

D-1 ii

POINT BEACH NUCLEAR PLANT LIST OF TABLES Title Paqe Airborne Particulates and lodine-131 Location E-01, Meteorological Tower...................

.................... 4 Location E-02, Site Boundary Control Center....................................... 5 Location E-03, West Boundary............

........................... 6 Location E-04, North Boundary............

...........................7 Location E-08, G. J. Francar Residence....................................... 8 Location E-20, Silver Lake College...............

........................ 9 Airborne Particulates, Gamma Isotopic Analyses......................................

10 Milk......................................

11 Well Water......................................

17 Lake Water......................................

18 Lake Water, Analyses on Quarterly Composites...................................... 22 Fish.

25 Shoreline Sediments.28 Soil.30 Vegetation.32 Aquatic Vegetation.35 Gamma Radiation, as Measured by TLDs.36 i-

POINT BEACH NUCLEAR PLANT

1.0 INTRODUCTION

The following constitutes the final 2005 Monthly Progress Report for the Environmental Radiological Monitoring Program conducted at the Point Beach Nuclear Plant, Two Rivers, Wisconsin. Results of analyses are presented in the attached tables. Data tables reflect sample analysis results for both Technical Specification requirements and Special Interest locations and samples are randomly selected within the Program monitoring area to provide additional data for cross-comparisons.

For gamma isotopic analyses, the spectrum covers an energy range from 80 to 2048 KeV. Specifically included are Mn-54, Fe-59, Co-58, Co-60, Zn-65, Zr-95, Nb-95, Ru-103, Ru-106, 1-131, Ba-La-140, Cs-134, Cs-137, Ce-141, and Ce-144. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected in soil and sediment samples. Specific isotopes listed are K-40, TI-208, Pb-212, Bi-214, Ra-226 and Ac-228. Unless noted otherwise, the results reported under "Other Gammas" are for Co-60 and may be higher or lower for other radionuclides.

All concentrations, except gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

1

POINT BEACH NUCLEAR PLANT 2.0 LISTING OF MISSED SAMPLES I

Expected Collection Sample Type Location Date Reason AP/AI AP/AI LW AP/AI AP/AI AP/AI E-02 E-02 E-06 E-03 E-03 E-01 01-20-05 01-2605 01-13-05 02-23-05 03-23-05 09-21-05 Sampler not running.

Sampler breaker tripped.

Water frozen.

Sampler breaker tripped.

No power to air sampler.

Power off due to modification of Met Tower which secured power to all receptacles.

NOTE: Page 3 is intentionally left out.

2

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

)

Location: E-01, Meteorological Tower Units: pCiM 3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (M 3)

Gross Beta 1-131 Date Vol.

Collected (M 3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-07-05 01-12-05 01-20-05 01-26-05 02-03-05 02-09-05 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 386 221 367 275 368 274 320 318 369 305 267 310 298 0.028 +/- 0.003 0.052 +/- 0.006 0.026 + 0.003 0.023 +/- 0.003 0.021 + 0.003 0.029 +/- 0.004 0.021 +/- 0.003 0.019 +/- 0.003 0.019 +/- 0.003 0.023 +/- 0.003 0.019 +/- 0.004 0.020 +/- 0.003 0.020 + 0.004

<0.020

<0.015

<0.009

<0.01 1

<0.010

<0.017

<0.021

<0.013

<0.012

<0.0.18

<0.019

<0.019

<0.012 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 08-11-05 08-17-05 08-24-05 08-31-05 09-07-05 09-12-05 09-21-05 09-28-05 276 326 259 302 304 354 250 302 305 310 213 290 0.010 +/- 0.003 0.033 +/- 0.003 0.023 + 0.004 0.021 +/- 0.003 0.029 +/- 0.004 0.033 +/- 0.003 0.023 +/- 0.004 0.022 +/- 0.004 0.024 +/- 0.004 0.023 +/- 0.004 0.047 +/- 0.006 NDb 0.022 +/- 0.004

<0.022

<0.01 7

<0.029

<0.023

<0.015

<0.013

<0.021

<0.011

<0.016

<0.014

<0.024 a

<0;017 I

1st Quarter Mean+/- s.d.

3rd Quarter Mean+/- s.d.

0.025 +/- 0.009

<0.015 0.026 +/- 0.009

<0.019 04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-19-05 05-25-05 06-02-05 06-08-05 06-16-05 06-23-05 06-30-05 265 343 297 335 26i 290 345 254 341 259 344 299 306 0.016 +/- 0.004 0.018 +/- 0.003 0.027 +/- 0.003 0.012 +/- 0.003 0.013 +/- 0.003 0.029 +/- 0.004 0.011 +/- 0.003 0.014 +/-0.003 0.015 +/- 0.002 0.025 +/- 0.004 0.018 +/- 0.003 0.012 +/- 0.003 0.026 +/- 0.003

<0.015

<0.013

<0.019

<0.012

<0.020

<0.023

<0.012

<0.014

<0.018

<0.027

<0.018

<0.022

<0.017 10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 12-08-05 12-13-05 12-21-05 12-28-05 346 303 258 304 300 316 333 259 302 347 219 344 303 0.024 +/- 0.004 0.010 +/- 0.003 0.026 +/-0.004 0.008 +/- 0.003 0.030 +/- 0.004 0.034 +/- 0.004 0.019 +/-0.003 0.027 +/-0.004 0.022 +/-0.004 0.021 +0.003 0.035 +/-0.005 0.030 +/-0.004 0.044 +/-0.005

<0.01 0

<0.017

<0.013

<0.012

<0.013

<0.016

<0.027

<0.012

<0.015

<0.012

<0.021

<0.013

<0.008 2nd Quarter Mean+/- s.d.

0.018 +0.006

<0.018 4th Quarter Mean+/- s.d.

0.025 +/- 0.010

<0.015 Cumulative Average 0.023 *40.009 <0.016 aVolume low; modif cation of Met Tower; power turned off at 12:00 on 09-12-05.

b "ND" = No data; see Table 2.0, Listing of Missed Samples.

4

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-02, Site Boundary Control Center Units: pCi/M 3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (M 3)

Gross Beta 1-131 Date Vol.

Collected (M 3 )

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-07-05 01-12-05 01-20-05 01-26-05 02-03-05 403 216 302 0.033 +/- 0.003 0.052 +/- 0.006 NDa NDa 0.022 + 0.004

<0.019

<0.015

<0.013 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 267 316 251 293 294 0.012 +/- 0.004 0.031 +/- 0.003 0.024 +/- 0.004 0.018 +/- 0.003 0.030 +/- 0.004

<0.023

<0.018

<0.030

<0.023

<0.016 02-09-05 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 259 302 302 350 298 259 304 301 0.027 + 0.004 0.027 + 0.004 0.025 +/- 0.004 0.026 +/- 0.003 0.022 +/- 0.003 0.015 +/- 0.004 0.018 +/- 0.003 0.022 +/- 0.004

<0.018

<0.022

<0.014

<0.013

<0.018

<0.019

<0.019

<0.012 08-11-05 08-17-05 08-24-05 08-31-05 09-07-05 09-12-05 09-21 -05 09-28-05 339 256 314 305 301 327 259 313 0.032 +/- 0.003 0.026 +/- 0.004 0.024 +/- 0.004 0.022 +/- 0.004 0.026 +/- 0.004 0.045 +/- 0.004 0.031 +/- 0.004 0.029 +/- 0.004

<0.014

<0.020

<0.01 1

<0.016

<0.014

<0.014

<0.015

<0.015 1st Quarter Mean+/- s.d.

0.026 +/- 0.010** <0.017 3rd Quarter Mean+ sad.

l-0.027 +/- 0.008

<0.018 04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-1 9-05 05-25-05 06-01-05 06-08-05 06-16-05 06-23-05 06-30-05 268 347 300 339 267 299 343 259 305 256 347 289 298 0.015 +/- 0.004 0.017 +/- 0.003 0.024 +/- 0.003 0.010 +/- 0.003 0.014 +/- 0.003 0.030 +/- 0.004 0.010 +/- 0.003 0.012 +/- 0.003 0.014 +/- 0.003 0.029 +/- 0.004 0.019 +/- 0.003 0.012 +/- 0.003 0.025 +/- 0.003

<0.015

<0.013

<0.019

<0.012

<0.020

<0.023

<0.012

<0.014

<0.021

<0.028

<0.018

<0.022

<0.017 10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 12-08-05 12-13-05 12-21 -05 12-28-05 357 305 260 294 291 296 334 251 293 342 219 346 303 0.023 +/- 0.003 0.010 +/- 0.003 0.026 +/- 0.004 0.011 +/- 0.003 0.028 +/- 0.004 0.036 +/- 0.004 0.022 +/- 0.003 0.032 +/- 0.005 0.025 +/- 0.004 0.019 +/- 0.003 0.034 +/- 0.005 0.029 +/- 0.004 0.041 +/- 0.005

<0.01 0

<0.017

<0.012

<0.012

<0.014

<0.017

<0.023

<0.012

<0.015

<0.012

<0.021

<0.012

<0.008 2nd Quarter Mean+ s.d.

4th Quarter Mean+/- s.d.

0.018 +/- 0.007 <0.018 0.026 +/- 0.009 <0.014 Cumulative Averaqe 0.024 +/- 0.009 <0.017 i

a""ND" = No data; see Table 2.0, Listing of Missed Samples.

5

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-03, West Boundary Units: pCi/M3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (m 3 )

Gross Beta 1-131 Date Vol.

Collected (mi 3 )

Gross Beta 0.010 1-131 0.030 Required LLD 0.010 0.030 Required LLD 01-07-05 01-12-05 01-20-05 01 05 02-03-05 02-09-05 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 390 216 346 260 346 259 302 346 300 260 301 0.027 +/- 0.003 0.050 +/- 0.006 0.032 +/- 0.004 0.021 +/- 0.003 0.024 +/- 0.003 0.027 +/- 0.004 0.024 +/- 0.004 NDa 0.019 +/-0.003 0.024 +/- 0.003 0.017 +/- 0.004 NDa 0.019 +/- 0.003

<0.020

<0.015

<0.01 0

<0.012

<0.01 1

<0.018

<0.022

<0.013

<0.018

<0.019

<0.012 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 08-11-05 08-17-05 08-24-05 08-31-05 09-07-05 09-12-05 09-21-05 09-28-05 276 326 259 302 303 348 256 302 304 309 338 259 302 0.010 +/- 0.003 0.031 +/- 0.003 0.023 +/- 0.004 0.023 +/- 0.003 0.032 +/- 0.004 0.033 +/- 0.003 0.023 +/- 0.003 0.019 +/- 0.003 0.020 +/- 0.003 0.025 +/- 0.004 0.047 +/- 0.004 0.040 +/- 0.005 0.029 +/- 0.004

<0.022

<0.017

<0.029

<0.023

<0.01 5

<0.013

<0.020

<0.011

<0.01 6

<0.01 4

<0.013

<0.01 5

<0.01 6 1st Quarter Mean+/- s.d.

0.026+/-0.009 <0.015 3rd Quarter Mean+/- s.d.

0.027 +/- 0.010 <0.01 7 04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-19-05 05-25-05 06-01-05 06-08-05 06-16-05 06-23-05 06-30-05 268 347 300 339 267 299 343 260 343 262 345 299 307 0.018 +/- 0.004 0.016 +/- 0.003 0.023 +/- 0.003 0.013 +/- 0.003 0.016 +/- 0.003 0.023 +/- 0.003 0.011 +/- 0.003 0.011 +/- 0.003 0.013 +/- 0.002 0.023 +/- 0.004 0.019 +/- 0.003 0.013 +/- 0.003 0.025 +/- 0.003

<0.015

<0.013

<0.019

<0.012

<0.020

<0.023

<0.012

<0.014

<0.018

<0.027

<0.018

<0.022

<0.017 10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 12-08-05 12-13-05 12-21 -05 12-28-05 352 297 259 303 300 306 343 260 302 347 219 345 303 0.026 +/- 0.004. <0.010 0.008 + 0.003 <0.017 0.025 +/- 0.004 <0.013 0.008 + 0.003 <0.012 0.026 +/- 0.004 <0.013 0.037 +/- 0.004 <0.016 0.019 +/- 0.003 <0.023 0.024 +/- 0.004 <0.012 0.023 +/- 0.004 <0.015 0.018 +/- 0.003 <0.012 0.037 +/- 0.005 <0.021 0.031 +0.004

<0.013 0.046 +/- 0.005 <0.008 2nd Quarter Mean+/- s.d.

0.017 +/- 0.005 <0.018 4th Quarter Meant s.d.

0.025 +/- 0.011

<0.014 Cumulative Averaae 0.024 +0.010 <0.016 a"ND" = No data; see Table 2.0, Listing of Missed Samples.

6

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-04, North Boundary Units: pCVm3 Collection:

Continuous, weekly exchange.

Date Vol.

Collected (M 3 )

Gross Beta 1-131 Date Vol.

Collected (M 3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-07-05 01-12-05 01-20-05 01-26-05 02-03-05 02-0905 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 370 205 329 247 328 246 286 289 327 287 247 288 286 0.035 +/-0.003 0.049 +0.006 0.035 +/-0.004 0.026 +/- 0.004 0.030 +/- 0.004 0.026 +/-0.004 0.027 +/-0.004 0.023 +/-0.004 0.025 +/-0.004 0.021 t0.003 0.021 +/-0.004 0.018 tO.003 0.020 +/- 0.004

<0.021

<0.016

<0.010

<0.013

<0.012

<0.019

<0.023

<0.015

<0.014

<0.019

<0.020

<0.020

<0.013 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 08-11-05 08-17-05 08-24-05 08-31 -05 09-07-05 09-12-05 09-21 -05 09-28-05 276 326 259 312 324 372 273 323 335 349 372 276 313 0.005 +/- 0.003 0.032 +/-0.003 0.026 +/- 0.004 0.019 +0.003 0.027 +/- 0.004 0.034 +/- 0.003 0.021 +/- 0.003 0.008 +/- 0.003 0.019 +/-0.003 0.023 +/- 0.003 0.038 +/- 0.004 0.030 +/- 0.004 0.023 +/- 0.004

<0.022

<0.017

<0.029

<0.022

<0.014

<0.013

<0.019

<0.010

<0.015 a

<0.012

<0.012

<0.014

<0.015 1st Quarter Means s.d.

04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-19-05 05-25-05 06-01-05 0.027 +/-0.008 <0.017 254 330 285 322 254 284 326 247 325 0.018 t0.004 0.016 t0.003 0.026 +/- 0.004 0.015 +t0.003 0.014 +/- 0.003 0.033 + 0.004 0.013 +0.003 0.017 +/- 0.004 0.016 +/- 0.003

<0.016

<0:013

<0.020

<0.012

<0.021

<0.024

<0.013

<0.015

<0.019 3rd Quarter Mean+ s.d.

10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 350 299 268 302 300 306 343 260 302 0.023 +/-0.010 0.026 +/- 0.004 0.009 +/-0.003 0.026 +/- 0.004 0.008 +/- 0.003 0.025 +/-0.004 0.032 +/- 0.004 0.020 -0.003 0.023 +/- 0.004 0.018 +/-0.003

<0.016

<0.010

<0.017

<0.012

<0.012

<0.013

<0.016

<0.022

<0.012

<0.015 06-08-05 06-16-05 06-23-05 06-30-05 251 327 299 306 0.025 +/- 0.004 0.016 +/- 0.003 0.010 +/- 0.003 0.025 +/- 0.003

<0.02 8

<0.019

<0.022

<0.017 12-08-05 12-13-05 12-21 -05 12-28-05 346 218 345 303 0.020 _ 0.003 0.036 +/- 0.005 0.031 +/-0.004 0.044 +/-0.005

<0.012

<0.021

<0.013

<0.008 2nd Quarter Mean+/-t s.d.

0.019 +/- 0.006

<0.018 4th Quarter Mean+/- s.d.

0.024 +/- 0.010 <0.014 0.024 +/-0.009 <0.016 Cumulative Average a Low counts; filter light.

7

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.

Location: E-08, G.J. Francar Residence Units: pCim 3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (m 3)

Gross Beta 1-131 Date Vol.

Collected (m 3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01-07-05 01-12-05 01-20-05 01-26-05 02-03-05 02-09-05 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 386 213 344 258 343 257 299 301 331 280 242 282

.300 0.033

  • 0.003 0.052 +/- 0.006 0.035 + 0.004 0.023 +/- 0.004 0.022 + 0.003 0.024 + 0.004 0.020 +/- 0.004 0.026 +/- 0.004 0.021 +/- 0.003 0.023 +/- 0.003 0.018 +/- 0.004 0.017 *0.003 0.027 +/- 0.004

<0.020

<0.016

<0.01 0

<0.012

<0.01 1

<0.018

<0.022

<0.014

<0.014

<0.01 9

<0.020

<0.021

<0.012 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 08-11-05 08-17-05 08-24-05 08-31-05 09-07-05 09-12-05 09-21-05 09-28-05 276 324 259 301 304 348 256 302 304 307 340 260 303 0.011 +/- 0.003 0.030 +/- 0.003 0.020 +/- 0.003 0.021 +/- 0.003 0.032 +/- 0.004 0.034 +/- 0.003 0.021 +/- 0.003 0.023 +/- 0.004 0.019 +/- 0.003 0.020 +/- 0.003.

0.045 +/- 0.004 0.039 +/- 0.005 0.027 +/- 0.004

<0.022

<0.01 7

<0.029

<0.023

<0.01 5

<0.013

<0.020

<0.01 1

<0.01 6

<0.014

<0.013

<0.01 5

<0.01 6

'I 1st Quarter Meah+/- s.d.

0.026 +/- 0.009 <d.016 3rd Quarter Mean+/- s.d.

0.026 +/- 0.009 <0.017 04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-19-05 05-25-05 06-01-05 06-08-05 06-16-05 06-23-05 06-30-05 264 344 297 353 265 296 341 258 340 303 298 303 303 0.016 0.018 0.024 0.013

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.003 0.013 +/- 0003 0.028 +/- 0.004 0.012 +/- 0.003 0.012 +/- 0.003 0.015 +/- 0.002

<0.015

<0.013

<0.01 9

<0.01 1

<0.020

<0.023

<0.012

<0.014

<0.01 8

<0.021

<0.020

<0.021

<0.017 10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 12-08-05 12-13-05 12-21-05 12-28-05 347 301 260 302 300 305 345 267 322 358 218 346 303 0.026 + 0.004 0.011 +/- 0.003 0.027 + 0.004 0.010 + 0.003 0.027 + 0.004

<0.010

<0.01 7

<0.012

<0.01 2

<0.01 3 0.041 t 0.004 <0.016 0.018 +/- 0.003 <0.024

0. 033 + 0.004

<0.012 0.022 +/- 0.003 <0.014 0.021 0.021 0.013 0.026

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003 0.016 +0.003 0.033 +/- 0.005 0.025 +/- 0.004 0.043 +/- 0.005

<0.01 1

<0.021

<0.013

<0.008 2nd Quarter Mean+/- s.d.

0.018 + 0.006 <0.017 4th Quarter Mean+/- s.d.

0.026 +/- 0.010

<0.014 Cumulative Averaqe 0.024 +/- 0.009 <0.016 8

POINT BEACH NUCLEAR PLANT Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1 31.

Location: E-20, Silver Lake Units: pCiM/3 Collection: Continuous, weekly exchange.

Date Vol.

Collected (M3)

Gross Beta 1-131 Date Vol.

Collected (m 3)

Gross Beta 1-131 Required LLD 0.010 0.030 Required LLD 0.010 0.030 01 05 01-12-05 01-20-05 01-26-05 02-03-05 02-09-05 02-16-05 02-23-05 03-03-05 03-10-05 03-17-05 03-23-05 03-30-05 390 217 346 261 344 259 302 303 346 293 248 306 299 0.032 +/-0.003 0.047 +/-0.006 0.030 +/-0.004 0.022 +/-0.003 0.023 +/- 0.003 0.028 +/- 0.004 0.026 +/- 0.004 0.025 +/- 0.004 0.016 0.003 0.023 +/- 0.003 0.019 +/- 0.004 0.018 +/-0.003 0.021 +/- 0.004

<0.020

<0.015

<0.01 0

<0.012

<0.01 1

<0.018

<0.022

<0.014

<0.013

<0.018

<0.020

<0.019

<0.012 07-06-05 07-14-05 07-20-05 07-27-05 08-03-05 08-11-05 08-17-05 08-24-05 08-31-05 09-07-05 09-12-05 09-21-05 09-28-05 278 324 258 302 303 348 257 302 304 302 347 258 302 0.009 +/-0.003 0.031 +/- 0.003 0.028 +/- 0.004 0.022 +/- 0.003 0.030 t 0.004 0.035 +/- 0.003 0.025 +/- 0.004 0.023 +/- 0.004 0.026 +/- 0.004 0.025 +/- 0.004 0.043 +/- 0.004 0.036 +/-0.005 0.025 +/-t0.004

<0.022

<0.017

<0.029

<0.023

<0.015

<0.013

<0.020

<0.01 1

<0.016

<0.014

<0.013

<0.015

<0.016 1st Quarter Means s.d.

04-06-05 04-13-05 04-20-05 04-28-05 05-04-05 05-11-05 05-19-05 05-25-05 06-01-05 06-08-05 06-16-05 06-23-05 06-30-05 3rd Quarter Mean t s.d.

266 349 299 338 268 297 344 264 341 343 262 298 308 0.025 +/- 0.008 0.014 +/-0.004 0.017 +/-0.003 0.025 + 0.003 0.012 +/-L 0.003 0.013 +/- 0.003 0.027 +/- 0.003 0.011 +/-0.003 0.011 0.003 0.013 +/-0.002 0.022 +/- 0.003 0.020 0.004 0.013 +/-0.003 0.030 +/- 0.004

<0.016

<0.015

<0.013

<0.019

<0.012

<0.019

<0.023

<0.012

<0.014

<0.018

<0.018

<0.022

<0.022

<0.017 10-06-05 10-13-05 10-19-05 10-26-05 11-02-05 11-09-05 11-17-05 11-23-05 11-30-05 12-08-05 12-13-05 12-21 -05 12-28-05 344 305 260 303 299 307 342 262 301 345 219 346 302 0.024 +/- 0.004 0.010.+ 0.003 0.024 +/- 0.004 0.008 +/- 0.003 0.030 +/-0.004 0.033 +0.004 0.020 +/-0.003 0.031 +/- 0.004 0.022 +/- 0.004 0.025 +/-0.003 0.034 +/- 0.005 0.031 +/-0.004 0.047 t 0.005 0.028 +/- 0.008

<0.017

<0.010

<0.017

<0.012

<0.012

<0.013

<0.016

<0.021

<0.012

<0.015

<0.012

<0.021

<0.013

<0.008 2nd Quarter Mean+/- s.d.

0.018 +/-0.007 <0.017 4th Quarter Mean+/- s.d.

0.026 +/-0.010

<0.014 Cumulative Average 0.024 +/- 0.009

<0.016 9

POINT BEACH NUCLEAR PLANT GAMMA EMITTERS IN QUARTERLY COMPOSITES OF AIR PARTICULATE FILTERS (Concentration pCi/m3) a Locatior Lab Code Be-7 Cs-1 34 Cs-1 37 Other Gammas' Volume Reg. LLD 0.01 0.01

( 0.10 )

M3 1 st Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-2080

- 2081,2

- 2083

- 2084

- 2085

- 2086 0.050 +/- 0.012 0.067 +/- 0.012 0.069 +/- 0.016 0.071 +/- 0.017 0.059 +/- 0.015 0.079 +/- 0.015

-0.0001 +/- 0.0006 0.0002 +/- 0.0006

-0.0005 +/- 0.0008 0.0003 +/- 0.0006

-0.0001 +/- 0.0006 0.0001 +/- 0.0007 0.0004 +/- 0.0006 0.0001 +/- 0.0008 0.0002 +/- 0.0006

-0.0004 +/- 0.0006 0.0003 +/- 0.0006 0.0005 +/- 0.0004 0.0006 +/- 0.0004

-0.0007 +/- 0.0009 0.0008 i 0.0007

-0.0003 +/- 0.0006

-0.0003 +/- 0.0008 0.0008 +/- 0.0007 4078 3296 3326 3735 3836 3914 2nd Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-4061

- 4062

- 4063

- 4064

- 4065

- 4066 0.079 0.080 0.095 0.080 0.078 0.074

+/- 0.015

+/- 0.019

+/- 0.017

+/- 0.015-

+/- 0.015

+/- 0.017

-0.0007 +/- 0.0007 0.0001 +/- 0.0057

-0.0004 +/- 0.0006 0.0002 +/- 0.0005 0.0003 +/- 0.0004 0.0003 +/- 0.0005 0.0005 i 0.0005 0.0001 t 0.0005 0.0001 i 0.0006 0.0004 +/- 0.0005 0.0002 + 0.0006

-0.0001 +/- 0.0007 0.0005 +/- 0.0007 0.0001 +/- 0.0006 0.0002 +/- 0.0005

-0.0001 +/- 0.0007

-0.0001 +/- 0.0005

-0.0004 +/- 0.0007 3942 3917 3979 3810 3965 3977 3rd Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-5883

- 5884

- 5885

- 5886

- 5887

- 5888 0.073 +/- 0.024 0.069 +/- 0.016-0.071 +/- 0.014 0.063 +/- 0.015 0.086 +/- 0.016 0.069 +/- 0.017

-0.0002 +/- 0.0007

-0.0002 +/- 0.0006

-0.0009 +/- 0.0008

-0.0001 +/- 0.0006 0.0005 +/- 0.0006 0.0005 +/- 0.0005 0.0001 0.0001

-0.0003 0.0002 0.0004

-0.0004

+/- 0.0005

+/- 0.0005

+/- 0.0006

+/- 0.0005

+/- 0.0005

+/- 0.0006

-0.0005 +/- 0.0006

-0.0002 +/- 0.0006

-0.0001 +/- 0.0007 0.0011 +/- 0.0006 0.0002 +/- 0.0006

-0.0003 i 0.0006 3491 3835 3884 4110 3884 3885 4th Quarter E-01 E-02 E-03 E-04 E-08 E-20 EAP-7521

- 7522

- 7523

- 7524

- 7525

- 7526 0.045 +/- 0.012 0.049 +/- 0.013 0.052 +/- 0.015 0.045 +/- 0.012 0.044 +/- 0.015 0.052 +/- 0.016

-0.0001 +/- 0.0005 0.0002 +/- 0.0005

-0.0001 +/- 0.0004

-0.0002 +/- 0.0005 0.0003 +/- 0.0005

-0.0003 +/- 0.0006

-0.0001 +/- 0.0005

-0.0005 +/- 0.0005

-0.0003 +/- 0.0004 0.0001 +/- 0.0004 0.0001 +/- 0.0004 0.0001 +/- 0.0005

-0.0002 +/- 0.0005

-0.0001 +/- 0.0006

-0.0001 +/- 0.0005 0.0001 +/- 0.0006

-0.0004 +/- 0.0007 0.0005 +/- 0.0006 3934 3891 3936 3942 3974 3935 a See Introduction 10

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLPS (Monthly Collections) l Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-1 40 Other Gammasa Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Other Gammas" E-11 Funk Dairy Farm 01-05-05 02-02-05 EMI-81 EMI-513 0.7 +/- 0.7 0.4 +/- 0.7 0.7 +/-0.4 1.3 +/-0.4

-0.04 +/- 0.13

-0.12 +/- 0.15 1235 +/- 105 1252 + 107 0.8 +/- 2.1 0.5 +/- 2.7

-0.2 +/- 2.5

-1.8 +/- 2.6 1.5 +/- 1.8

-0.8 +/- 1.8 4.0 +/- 2.4

-1.4 +/- 2.8 04-13-05 05-04-05 EMI-1819 EMI-2338 0.2 +/- 0.5

-0.4 +/- 0.6 0.3 +/- 0.3 0.7 +/- 0.4 0.09 +/- 0.15

-0.06 +/- 0.14 1314 +/- 104 1351 +/- 120

-0.6+/-3.0 1.1 2.5

-1.0 +/- 2.7 1.5 2.5 3.3 +/- 2.4 0.9 +/- 2.0

-0.2 +/-2.1 2.5 i2.2 03-03-05 EMI-960 0.8 +/- 0.8 0.7 +/- 0.4

-0.05 +/- 0.15 1305 +/- 93

-0.2 +/- 2.1

-1.6 +/- 2.1 2.9 +/- 1.6 1.9 +/- 2.1 06-01-05 EMI-2927

-0.3 +/- 0.6 0.9 +/- 0.3

-0.03 +/- 0.13 1357 +/- 104

-1.8 i 2.3

-0.6 i 0.4 0.5 +/- 1.5 0.6 +/- 2.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 8 See Introduction.

11

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-137 Ba-La-140 Other Gammasa Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Other Gammasa E-1 1 Funk Dairy Farm 07-13-05 08-10-05 EMI-3928 EMI-4615

-0.7 +/- 0.7

-0.2 +/- 0.6 1.0 +/- 0.4 1.0 +/- 0.4

-0.03 +/- 0.15

-0.02 +/- 0.11 1281 +/-103 1331 +/-116 0.3 +/- 2.5

-0.4 +/- 3.1 2.1 +/-2.1 1.4 +/-2.7 1.4 +/- 1.4 2.1 +/- 1.3

-1.2 +/- 2.4 2.1 +/- 2.7 10-12-05 11:09-05 EMI-5725 EMI-6391' 0.6 +/- 1.0

-0.7 +/- 0.8 0.5 +/- 0.3 1.2 +/- 0.4

-0.06 +/- 0.15 0.02 +/- 0.15 1305 +/- 108 1351 +/- 114

-12.4 +/- 3.5 2.0 +/- 2.4

-2.7 +/- 2.8

-0.7 +/- 2.8 3.0 +/- 2.3

-0.5 +/- 2.0

-1.4 +/- 2.6 2.6 +/-2.7 09-14-05 EMI-5093 0.4 +/- 0.6 0.6 +/- 0.3

-0.11 +/- 0.18 1358 +/- 115

-2.7 +/- 2.0 0.0 +/- 2.5 0.2 +/- 1.9 1.0 +/- 2.8 12-14-05 EMI-7096 0.4 +/- 0.8 0.9+/-0.4

/

-0.03 +/- 0.13 1403 +/- 119

-0.8 +/- 1.9

-0.1 +/- 2.2 2.3 +/- 1.6 -

-3.0 +/- 3.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0

" See Introduction.

12

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections) i Sample Description and Concentration (pCi/L)

E-21 Strutz Dairy Farm Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-134 Cs-137 Ba-La-140 Other Gammas" Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-137 Ba-La-140 Other Gammas' 01-05-05 EMI-82 0.4 +/- 0.7 0.6 +/- 0.3

-0.01 +/-0.13 1316 +/- 114

-0.1 +/-2.7

-0.4 +/- 2.6 0.9 +/- 1.8 0.8 +/- 2.7 04-13-05 EMI-1 820 0.4 +/- 0.7 0.3 +/- 0.2

-0.03 + 0.15 1294 +/- 100

-0.1 +/-2.7 0.8 +/- 2.7 2.6 +/- 1.7 0.8 +/- 2.3 02-02-05 EMI-514 0.1 +/-0.6 0.4 +/- 0.4 0.08 +/- 0.17 1380 +/- 110 0.5 +/- 2.8

-2.4 +/- 3.0 0.5 +/- 2.5

-0.7 +/- 3.2 05-04:05 EMI-2339 0.1 +/-0.6 0.8 +/- 0.4

-0.09 +/- 0.17 1246 +/- 105 2.1 +/- 3.1 0.1 +/-2.8

-1.9 +/- 2.4

-0.8 +/- 2.7 03-03-05 EMI-961 0.3 +/- 0.7 1.1 +/-0.4 0.05 i 0.15 1320 +/- 95 1.9 i 2.3

-1.7 +/-2.3

-3.5 +/-2.1 1.2 +/-2.1 06-01-05 EMI-2928 0.1 +/-0.6 '

0.4 +/-0.3

-0.11 +/- 0.15 1402 +/- 104 1.3 +/- 2.4

-0.4 +/- 2.6

-0.7 +/- 2.1

-1.5 +/- 2.3 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 a See Introduction.

13

POINT BEACH NUCLEAR PLANT PRAbIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCilL)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-137 Ba-La-140 Other Gammas" Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-1 37 Ba-La-140 Other Gammasa E-21 Strutz Dairy Farm 07-13-05 08-10-05 EMI-3929 EMI-4616

-0.3 +/- 0.6 0.2 +/- 0.5 0.7 +/- 0.3 0.6 +/- 0.3

-0.05 +/- 0.15

-0.15 +/- 0.12 1394 +/- 107 1500 +/- 119 0.2 +/- 2.5 3.2 +/- 2.8 0.7 +/- 2.2

-1.5 +/- 3.0 2.5 +/- 1.5 3.6 +/- 2.2

-1.4 +/- 2.4

-1.2 +/- 2.7 10-12-05 11-09-05 EMI-5726 EMI-6392 0.5 +/- 0.7

-0.3 +/- 0.6 0.5 +/- 0.3 0.4 +/- 0.3

-0.01 0.1 5 0.08 +/- 0.16 1383 +/- 101 1335 +/- 116

-0.3 +/- 2.3

-10.2 +/- 3.1 0.6 +/- 2.4 0.7 +/- 3.0

-2.2 +/-2.1 1.4 +/- 2.0

-0.3 +/- 2.4 1.5 +/- 2.5 09-14-05 EMI-5094

-0.2 +/- 0.6 0.5 +/- 0.3

-0.18 +/- 0.18 1373 +/- 111

-0.7 t 1.7 2.0 +/-2.2 1.2 +/-2.1 0.6 +/-2.8 12-14-05 EMI-7097,8

-0.5 +/- 0.7 0.6 +/- 0.3 0.03 +/- 0.14 1322 +/- 76

-12.8 +/- 3.1 1.4 +/- 2.4 /

-1.3 +/- 2.0

-0.9 +/- 2.5 /

Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 a See Introduction.

14

POINT BEACH NUCLEAR PLANT RiADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-1 37 Ba-La-140 Other Gammas Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-137 Ba-La-140 Other Gammas" 01-05-05 EMI-83

-1.5 i 0.9 2.4 i 0.5

-0.02 +/- 0.16 1347 i 112

-3.3 i 2.4

-1.3 i2.1

-0.5 i 2.0 0.3 +/- 2.3 04-13-05 EMI-1821 1.1 +/-1.2 1.4 +/- 0.5

-0.02 +/- 0.14 1395 +/- 113 0.9 +/- 2.6 0.4 +/- 2.8

-0.3 +/-2.1 1.3 +/- 2.6 E-40 Barta 02-02-05 EMI-515

-0.8 +/- 0.7 1.1 +/-0.4 0.20 +/- 0.23 1355 +/- 118 2.5 +/- 3.0 0.3 +/- 2.3 0.2 +/- 2.3

-0.7 +/- 2.6 05-04-05 EMI-2340 0.3 +/- 0.6 0.9 +/- 0.4 0.16 +/- 0.19 1419 +/- 129

-0.2 +/-3.0

-0.6 +/- 2.4

-0.6 +/- 2.4 1.6 +/- 2.5 03-03-05 EMI-962

-0.5 +/- 0.7 1.6 +/- 0.4 0.00 +/- 0.15 1392 +/- 103

-0.7 +/- 2.4 0.4 +/- 1.8

-1.3 +/- 2.2

-1.0 +/- 2.1 06-01-05.

EMI-2929 0.3 +/- 0.6 0.9 +/- 0.3

-0.10 +/- 0.17 1348 +/- 110 0.1 +/-2.4 0.0 +/- 2.3

-2.8 +/- 2.9 0.1 +/-2.4 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 a See Introduction.

15

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN MILK SAMPLES (Monthly Collections)

Sample Description and Concentration (pCi/L)

Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-1 37 Ba-La-140 Other Gammasa Collection Date Lab Code Sr-89 Sr-90 1-131 K-40 Cs-1 34 Cs-1 37 Ba-La-140 Other Gammasa 07-13-05 EMI-3930

-0.1 +/- 0.7 1.1 +/-0.4 0.06 +/- 0.17 1472 +/- 113

-1.0 +/- 2.6

-3.4 +/- 2.6

-1.7 +/- 1.8 0.1 +/-2.7 10-12-05 EMI-5727 0.2 +/- 0.7 1.0 +/-0.4

-0.08 +/- 0.13 1267 +/- 115

-0.7 +/- 2.1 1.2 +/- 2.3

-2.6 +/- 2.2 0.3 +/- 2.5 E-40 Barta 08-10-05 EMI-4617 0.2 +/- 0.6 0.8 +/- 0.3

-0.08 +/- 0.12 1278 +/- 121 2.4 +/- 2.2

-2.1 + 2.1

-2.1 +/- 2.1

-2.5 +/- 2.4 11-09-05 EMI-6393 0.2 +/- 0.8 1.1 +/-0.4

-0.11 +/- 0.18 1386 +/- 114

-5.0 +/- 2.6 0.1 +/-2.5

-1.1 +/- 2.3 0.0 +/- 2.7 09-14-05 EMI-5095

-0.1 +/-0.7 1.4 +/- 0.4

-0.01 +/- 0.21 1405 +/- 109

-1.4 +/- 1.7 1.4 +/- 2.2 1.1 +/-1.6

-0.2 +/- 2.4 12-14-05.

EMI-7099 0.2 +/-0.7 -

0.8 +/- 0.4

-0.10 +/- 0.14 1300 +/- 105 /

-1.7 +/- 2.1 3.1 +/-2.3

-0.4 +/- 2.1 0.1 +/-2.4 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 Required LLD 5.0 1.0 0.5 5.0 5.0 5.0 15.0 a See Introduction.

16

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN WELL WATER SAMPLES, E-10 (Quarterly Collections) 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Req.

LLD Collection Date 01-14-05 04-14-05 07-13-05 10-13-05 Lab Code EWW-232 EWW-1 914 EWW-3966 EWW-5754 Gross Beta 0.9 +/-11.6 0.5 +/-1.8 1.0 +/-11.8 0.2 +/- 1.8 4.0 H-3

-16.8 +/- 85.4

-4.4 +/- 76.2 29.6 +/- 104.5 104.5 +/- 90.1 500 Sr-89 0.2 +/-0.6 0.7 +/-0.6 0.3 +/- 0.6

-0.1 +/- 0.4 5.0 Sr-90 0.1 +/- 0.3

-0.1 +/- 0.2

-0.2 +/- 0.4 0.0 +/- 0.2 1.0 1-131 0.09 +/- 0.16

-0.04 +/-0.15 0.06 +/-0.17

-0.10 +/-0.13 0.5 Mn-54

-2.8 +/-4.6 0.7+/-1.6 0.8 +/-3.8

-0.1 +/-2.7 10 Fe-59 7.5 +/- 9.6

-1.7 +/- 3.2

-3.0 +/- 6.7 1.4 +/- 7.5 30 Co-58

-1.9 +/-4.5

-0.5 +/-1.7

-1.3 +/- 2.7 1.8 +/- 3.4 10 Co-60 5.6 +/-5.4 1.0 +/-1;8 0.9 +/-4.2 1.1 t3.0 -

10 Zn-65 4.4 +/- 9.3

-4.6 +/- 3.8 3.1 +/- 6.8

-1.5 +/- 9.0 30 Zr-Nb-95

-2.7 +/-3.5 0.6 +/- 1.8 2.7 +/- 3.4

-2.9 +/- 3.5 15 Cs-134

-0.5 +/- 4.3

-0.9 +/- 2.0 1.5 +/- 3.8

-1.6 +/- 3.6 10 Cs-137 1.4 +/-4.2 0.7 +/-1.7 2.0 +/-3.1 0.8 +/-4.0 10 Ba-La-140 9.4+/-5.9 1.5+/-1.8b

-2.3+/-3.9

-0.1 +/-4.6 15 Other Gammasa

-2.5 +/- 3.5

-1.9 +/- 1.7

-0.1 +/- 2.8 0.2 +/- 3.6 30 a Ru-103 b corrected value 17

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-01 (Meteorological Tower)

Collection: Monthly composites Units: pCi/L

)

Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Other Gammasa Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 C6-60 Zn-65 Zr-Nb Cs-134 Cs-137 Ba-La-140 Other Gammas' Lab Code, Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-I 37 Ba-La-140 Other Gammas' ELW-235 01-13-05 4.0 i 0.7 0.02 +/- 0.17 9.4 +/- 19.1

-0.9 +/- 2.0 1.7 +/- 3.5 0.6 +/- 1.9

-0.4 +/- 1.8

-6.9 +/- 4.7 1.1 +/- 2.0 0.8 +/- 2.3

-1.7 +/- 2.2

-0.3 +/- 1.9 1.5 +/- 2.2 ELW-2539 05-11-05 1.4 i 0.3

-0.12 +/- 0.15 26.7 +/- 20.2 0.5 +/- 2.1

-1.1 +/- 4.6 0.0 +/- 2.0

-1.9 +/- 2.4

-3.7 +/- 4.7

-1.0 +/- 2.2 1.4 +/- 2.6 0.4 +/- 2.5 0.7 +/- 3.2

-3.0 +/- 2.6 ELW-5177 09-14-05 2.7 +/- 0.6

-0.09 +/- 0.16 1.3 +/- 15.1 0.4 +/- 1,8

-1.7 +/- 3.4 2.1 +/- 1.6

-0.3 +/- 1.9 1.9 +/- 3.7

-0.8 +/- 1.8 0.6 +/- 1.7

-1.0 +/- 1.8 1.2 +/- 1.6

-1.0 +/- 1.6 ELW-679 02-11-05 2.5 +/- 0.6 0.13 +/- 0.15

-8.7 +/- 21.3 1.9 +/-2.8 2.1 +/- 5.1

-1.2 +/- 2.7 0.9 +/- 3.0

-5.2 +/- 5.9 1.0 +/- 2.6

-1.0 +/- 3.3

-2.6 +/- 2.6

-4.2 +/- 3.2

-2.2 +/- 2.6 ELW-3183 06-08-05 2.0 +/- 0.4

-0.02 +/- 0.17

-8.7 +/- 15.6

-1.1 +/- 1.6 1.2 +/- 2.9 0.4 +/- 1.5 0.7 +/- 1.7

-0.7 +/- 3.6 0.7 +/- 1.4

-0.1 +/- 1.9 1.0 i 1.8

-1.0 +/- 1.8

-1.2 t 1.7 ELW-5748,9 10-12-05 1.5 +/- 0.2

-0.17 +/- 0.20 7.2 +/- 26.4

-0.6 i 1.7

-2.8 i 3.5 1.0 i 2.0 0.0 i 1.9

-1.0 +/- 4.2

-2.7 +/- 2.3 1.0 +/- 1.6

-0.2 +/- 1.8 3.8 +/- 2.0 1.7 +/- 1.9 ELW-1124 03-09-05 3.1 +/- 0.7

-0.13 +/- 0.17 4.0 +/- 20.8 0.0 +/- 2.5 1.4 +/- 2.9

-1.2 +/- 2.7

-0.2 + 2.7

-3.4 +/- 5.5

-4.0 +/- 2.5

-0.4 +/- 2.5

-0.8 +/- 2.7

-2.4 +/- 4.4 0.5 +/- 2.5 ELW-4017 07-14-05 4.1 i 0.5 0.03 +/- 0.16 1.8 i 18.6

-1.0 +/- 2.6 3.3 +/- 4.0 0.9 +/- 2.3 0.9 +/- 2.4

-3.5 +/- 5.5

-0.6 +/- 2.4 0.6 +/- 2.8 0.8 +/- 2.8 0.6 +/- 2.7

-1.2 +/- 2.5 ELW-6467 11-10-05 2.0 +/- 0.6

-0.11 +/- 0.15

-14.4 +/- 25.3

-2.6 i 3.4

-1.0 i 5.2

-3.8 +/- 2.9

-0.4 +/- 3.6 3.7 +/- 6.8 3.2 +/- 3.2

-0.5 +/- 2.7

-1.0 +/- 3.0

-8.8 +/- 4.3

-0.6 +/- 3.2 ELW-1909 04-14-05 2.6 +/- 0.7

-0.01 +/- 0.16

-7.9 +/- 25.4

-4.0 +/- 3.4 1.5 +/- 6.0 4.2 +/- 3.0 1.1 +/- 3.6

-5.8 +/- 7.2

-0.9 +/- 3.2

-2.1 +/- 4.2

-0.2 i 3.5

-3.3 3.7

-1.6

  • 3.2 ELW-4677 08-12-05 2.1 +/- 0.4

-0.01 +/- 0.12 4.4 +/- 24.5

-1.5 +/- 3.2 1.1 +/- 6.2

-2.1

+/- 3.1

-0.7 +/- 4.1 0.7 +/- 6.5 2.9 +/- 2.6 0.7 +/- 2.9 2.0 +/- 3.4

-2.5 +/- 2.1

-2.1 +/- 3.0 ELW-7100 12-13-05 2.7 +/- 0.7

-0.09 i 0.13

-8.3 +/- 27.8 0.7 +/- 3.2

-0.3 +/- 7.4

-0.8 +/- 2.5

-1.2 +/- 3.6 2.4 +/- 9.9 "

1.6 3.7

-4.4 +/- 4.5

-2.3 + 3.4 /

-0,9 +/- 4.0 2.4 +/- 3.4 /

Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30.

15 10 10 15 30 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 a Ru-103 18

POINT BEACH Lake water, analyses for gross beta, iodine-131 and gamma emitting isotopes.

Location: E-05 (Two Creeks Park)

Collection: Monthly composites Units: pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other gammas' ELW-236 01-13-05 6.0 +/- 0.7 0.12 +/- 0.16 8.2 +/- 20.3 2.7 +/- 2.0 0.6 +/- 4.6 0.7 +/- 2.2 0.4 +/- 2.6

-3.3 +/- 4.8

-0.7 +/- 2.2

-0.1 +/- 2.5

-0.7 +/- 2.5 0.4 +/- 2.5

-0.3 +/- 2.2 ELW-680 02-11-05 3.0 +/- 0.6 0.08 +/- 0.17

-7.9 +/- 24.1 2.2 +/- 3.1

-6.1 +/- 6.4

-0.3 +/- 3.5

-2.2 +/- 4.1

-11.4 +/- 7.2 1.2 +/- 2.9 2.3 +/- 3.8

-1.3 +/- 3.2

-4.7 +/- 3.2

-3.6 +/- 3.2 ELW-1125 03-09-05 3.4 +/- 0.7

-0.25 +/- 0.17 11.3 +/- 19.7

-2.3 +/- 1.9 2.3 +/- 3.3

-1.1 +/- 1.7 0.4 +/- 2.0

-1.8 +/- 4.8

-0.2 +/- 2.1 0.9 +/- 2.2 0.1 +/- 2.3

-1.7 +/- 2.2 0.1 +/- 2.3 ELW-1910 04-14-05 3.6 +/- 0.7 0.01

-28.0

-0.2 4.5 2.3 1.8

-5.2 2.0

-0.5

-0.9 3.1

-4.0

+/- 0.16

+/- 28.0

+/- 2.5

+/- 5.8

+/- 3.3

+/- 2.9

+/- 6.8

+/- 2.8

+/- 3.6

+/- 3.5

+/- 4.8

+/- 3.0 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other Gammas' ELW-2540 05-11-05 1.6 +/- 0.4

-0.27 +/- 0.16

-11.6 +/- 18.9

-1.0 +/- 2.0

-4.5 +/- 3.9

-0.5 +/- 2.0 0.1 +/- 1.7

-2.9 +/- 4.9

-0.3 +/- 2.1

-1.2 +/- 2.0 1.2 +/- 2.5 2.6 +/- 1.9

-1.7 +/- 2.4 ELW-3184 06-08-05 1.3 +/- 0.3

-0.10 +/- 0.15

-24.0 +/- 18.4 1.0 +/- 1.7

-0.2 +/- 2.7 2.0 +/- 1.8 0.1 +/- 1.4

-6.3 +/- 3.7 1.0 +/- 1.7

-1.8 +/- 1.9

-0.2 +/- 1.9

-2.1 +/- 2.0

-1.1 +/- 2.0 ELW-4018 07-14-05 5.1 +/- 0.6

-0.03 +/- 0.14

-0.3 +/- 16.4

-3.0 +/- 2.2 0.9 +/- 3.8 1.0 +/- 2.2

-2.7 +/- 2.4

-3.2 +/- 4.9 2.2 +/- 2.3

-1.6 +/- 2.2 1.4 +/- 2.2 0.7 +/- 2.9

-2.4 +/- 1.7 ELW-4678 08-12-05 1.9 +/- 0.4

-0.09 +/- 0.13

-11.1 +/- 25.7

-0.2 +/- 3.2 3.9 + 6.1

.-0.6 +/- 2.8

-1.4 +/- 3.3

.0.3 +/- 6.1

-1.2 +/- 3.5 3.2 +/- 3.1

-1.6 +/- 3.2 1.3 +/- 3.4 1.5 +/- 3.1 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-I 37 Ba-La-140 Other Gammasa ELW-5178,9 09-14-05 2.9 +/- 0.4 0.08 +/- 0.22

-10.5 +/- 18.1

-0.5 +/- 1.8

-4.5 +/- 3.4 0.9 +/- 2.0 0.5 +/- 1.5

-2.4 +/- 5.4 1.6 +/- 1.9

-4.8 +/- 2.6

-1.2 +/- 2.6 1.4 +/- 1.6 1.9 +/- 2.3 ELW-5750 10-12-05 1.7 +/- 0.4

-0.08 +/- 0.14

-26.2 +/- 24.3

-0.7 +/- 2.2 3.1 +/- 3.3

-0.7 +/- 2.0

-0.9 +/- 2.4

-3.0 +/- 4.4 2.8 +/- 2.1

-6.1 +/- 2.6 0.1 +/- 2.7

-0.3 +/- 1.8

-1.7 +/- 2.3 ELW-6468 11-10-05 2.6 +/- 0.6

-0.24 +/- 0.18

-18.8 +/- 31.6 1.8 +/- 3.3 2.3 +/- 5.1 1.9 +/- 2.5 0.8 +/- 3.5

-2.1 +/- 7.0

-3.1 +/- 3.2 0.6 +/- 2.9 0.8 +/- 3.4 3.1 +/- 3.3

-1.2 +/- 3.0 ELW-7101 12-13-05 2.4 0.18

-22.4

-1.1

-0.1

-1.4

-1.0

-6.0

-1.9

-2.5 1.8

-6.1

-1.2

+/- 0.6'

+/- 0.24

+/- 19.7

+/- 2.1

+/- 3.7

+/- 1.9

+/- 2.3

+/- 5.1'

+/- 2.3

+/- 2.2

+/- 2.3 /

+/- 2.0k

+/- 2.1 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 a Ru-1 03 19

POINT BEACH Lake water, analyses for gross beta, iodine-1 31 and gamma emitting isotopes.

Location: E-06 (Coast Guard Station)

Collection: Monthly composites Units: pCi/L

'1 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other Gammasa NSb ELW-681 02-11-05 3.2 i 0.6 0.00 +/- 0.18

-15.7 +/- 21.3

-1.6 +/- 1.9 0.5 +/- 4.3

-1.5 +/- 1.9

-2.3 +/- 2.2

-4.8 +/- 4.5

-0.1 +/- 2.0

-1.8 +/- 2.5

-1.3 +/- 2.5 0.8 +/- 2.1

-2.3 +/- 2.2 ELW-1 126 03-09-05 2.2 +/- 0.4 0.15 +/- 0.24 12.1 +/- 17.2

-0.2 +/- 2.0

-0.9 +/- 3.3 1.9 +/- 2.1 1.1 +/- 2.1 1.0 +/- 3.7

-1.2 +/- 2.5 2.2 +/- 2.0

-0.4 +/- 1.7 0.4 +/- 2.6 0.9 +/- 1.8 ELW-1911,2 04-14-05 2.9 +/- 0.5

-0.06 +/- 0.18 25.3 +/- 16.4 0.1 +/- 1.9 0.8 +/- 3.0

-2.5 +/- 3.2

-2.1 +/- 2.1

-0.6 +/- 3.8

-2.6 +/- 2.1 0.7 +/- 2.0 0.2 +/- 2.2 4.5 +/- 2.1

-0.4 +/- 2.0 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Other Gammas' ELW-2541 05-11-05 1.2 +/- 0.3

-0.01 +/- 0.18 5.9 +/- 15.0

-2.5 +/- 2.2

-0.2 +/- 4.0

-1.4+/- 2.0

-2.3 +/- 2.2 1.2 +/- 3.9 1.7 +/- 2.1

-0.3 +/- 1.9

-0.4 +/- 2.6

-0.9 +/- 2.8 0.8 +/- 1.8 ELW-3185 06-08-05 1.8 +/- 0.4 0.06 +/- 0.15

-9.4 +/- 23.2 0.7 +/- 2.5 0.5 +/- 5.5 0.5 +/- 2.1 3.6 +/- 3.3 3.3 +/- 5.0 1.7 +/- 2.4 2.7 +/- 2.8 1.2 +/- 3.0 0.3 +/- 3.5

-4.2 +/- 2.6 ELW-4019 07-15-05 3.9 +/- 0.5 0.12 +/- 0.14 3.5 +/- 24.8 2.3 +/- 2.8

-0.4 +/- 5.7 0.2 +/- 2.7

-2.4 +/- 2.7

-0.1 +/- 7.0

-6.4 +/- 3.0

-1.2 +/- 3.0 0.7 +/- 2.7

-2.6 +/- 4.4 3.3 +/- 2.7 ELW-4679 08-12-05 1.8 +/- 0.4

-0.02 +/- 0.14 21.3 +/- 28.1 0.9 +/- 2.7

-2.2 +/- 6.2 0.7 +/- 2.7 1.0 +/- 3.3

-3.1 +/- 6.4

-2.6 +/- 3.1

-0.5 +/- 2.4 1.5 +/- 3.0 1.4 +/- 3.4

-0.6 +/- 3.3 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10.

15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other Gammas' ELW-5180 09-14-05 2.0 +/- 0.6 0.07 +/- 0.19

-8.0 +/- 17.6

-0.2 +/- 1.7

-0.6 +/- 3.5

-0.4 +/- 1.6

-1.2 +/- 1.8

-1.1 +/- 4.0 0.1 +/- 1.5

-0.2 +/- 1.8 1.2 +/- 2.1

-1.3 +/- 2.1

-1.0 +/- 2.1 ELW-5751 10-12-05 3.6 +/- 0.8 0.02 +/- 0.15 21.3 +/- 25.6 1.0 +/- 3.5 0.7 +/- 5.7

-2.3 +/- 3.6 4.8 +/- 5.0

-1.1 +/- 7.4

-1.1 +/- 3.2 0.0 +/- 2.9 2.5 +/- 3.8

-3.6 +/- 4.9

-0.6 +/- 3.1 ELW-6469 11-10-05 2.4 +/- 0.6

,0.06 +/- 0.20

-3.7 +/- 20.0

-2.9 +/- 2.7

-0.4 +/- 3.6

-1.9 +/- 2.6 2.1 +/- 3.4

-4.3 +/- 2.8

-2.5 +/- 2.9 1.7 +/- 2.2

-2.0 +/- 2.6 1.3 +/- 3.7

-12.0 +/- 2.2 ELW-7102 12-13-05 3.3 +/-

-0.10 +/-

-13.1 +/-

0.3 +/-

1.2 +/-

-1.3 +/-

1.4 +/-

-4.0 +/-

3.1 +/-

-8.0 +/-

0.2 +/-

-0.9 +/-

-1.7 +/-

0.7 -

0.16 '

22.2 -

2.4 4.2 2.0 1.9 4.8 2.3 3.0 '

2.5 2.1 2.6 /

Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 a Ru-1 03 b"NS" = No sample; see Table 2.0, Listing of Missed Samples.

20

POINT BEACH Lake water, analyses for gross beta, iodine-I 31 and gamma emitting isotopes.

Location: E-33 (Nature Conservancy)

Collection: Monthly composites Units:

pCi/L Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Other Gammasa ELW-237 01-13-05 3.1 +/- 0.6 ELW-682 02-11-05 3.4 +/- 0.6 0.11

-0.8

-0.6

-1.5 1.3

-0.9

-3.8 1.1 1.6

-0.8

-0.6 2.0

+/- 0.15

+/- 16.1

+/- 1.5

+/- 2.9

+/- 1.5

+/- 1.5

+/- 3.3

+/- 1.7

+/- 1.7

+/- 1.7

+/- 1.6

+/- 1.7

-0.09

-15.4

-1.7 0.3 0.1 2.0

-1.4

-0.5 0.3 1.4 0.9 0.3

+/- 0.15

+/- 27.3

+/- 2.7

+/- 6.9

+/- 3.3

+/- 3.8

+/- 6.3

+/- 3.1 i 3.2

+/- 3.4

+/- 2.8

+/- 3.1 ELW-1 127 03-09-05 3.4 +/- 0.5

-0.11 +/- 0.17

-4.9 +/- 21.9

-0.1 +/- 2.1 2.0 +/- 3.1

-0.2 +/- 2.0

-0.6 +/- 1.9

-3.1 +/- 4.3 0.6 +/- 2.2 1.1 +/- 2.4

-0.8 +/- 2.4 3.1 +/- 2.0 0.6 +/- 2.2 3.2

-0.10 28.3 2.4 1.1

-2.2

-1.3 2.1

-1.1

-3.0 0.2 6.1

-2.2

+/- 0.6

+/- 0.16

+/- 25.6

+/- 3.3

+/- 5.6

+/- 2.9

+/- 3.7 i 6.0

+/- 2.9

+/- 3.1

+/- 3.1

+/- 4.2

+/- 2.1 ELW-1913 04-14-05 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Other Gammas" ELW-2542 05-11-05 1.5 +/- 0.4

-0.11 +/- 0.16

-23.4 +/- 20.8 0.2 +/- 2.1

-0.1

+/- 3.6 0.1 +/- 2.3 0.4 +/- 2.4

-6.2 +/- 4:7

-0.2 +/- 2.1 2.6 +/- 2.3 2.8 +/- 2.6

-0.4 +/- 2.4

-2.4 +/- 2.7 ELW-3186 06-08-05 2.2 +/- 0.4

-0.01 +/- 0.14 2.5 +/- 12.2

-0.5 +/- 1.5 1.8 +/- 2.7 0.1 +/-.1.5

-0.7 +/- 1.8 0.7 +/- 3.0 1.9 +/- 1.5

-1.7 +/- 2.1

-1.2 +/- 1.6

-2.9 +/- 1.6

-1.2 +/- 1.6 ELW-4020 07-14-05 3.2 +/- 0.6 0.13 +/- 0.16

-8.6 +/- 16.6 0.6 +/- 2.1

-0.6 +/- 3.7

-0.9 +/- 1.9 1.4 +/- 2.1

-2.6 +/- 4.3

-1.0 +/- 2.5 1.7 +/- 2.5 1.1

+/- 2.4

-1.3 +/- 3.0

-1.0 +/- 1.8 ELW-4680 08-12-05 10.6 +/- 1.1

-0.12 +/- 0.12

-21.1 +/- 17.0 1.0 +/- 2.6 1.4 +/- 3.5

-0.7 +/- 2.3

-1.6 +/- 3.9 2.2 +/- 4.3

-1.5 +/- 2.8

-0.8 +/- 3.1 1.2 +/- 3.3

-0.5 +/- 3.3

-2.3 +/- 2.2 b

Req. LLD 4.0 0.5 10 30 10 10 3Q 15 10 10.

15 30 Lab Code Date Collected Gross beta 1-131 Be-7 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Other Gammas' ELW-5181 09-15-05 3.2 +/- 0.7

-0.04 +/- 0.15 4.9 +/- 18.4

-1.3 +/- 1.9

-6.0 +/- 3.9 0.1 +/- 1.9

-0.3 +/- 1.8

-3.5 +/- 3.9

-0.1 i 2.0 0.1 +/- 2.0 0.9 +/- 2.1

-1.5 +/- 2.2 0.2 +/- 2.0 ELW-5752 10-12-05 1.9 +/- 0.4 0.02 +/- 0.14

-3.1 t 18.5

-0.4 i 2.6

-0.5 +/- 6.4 1.0 i 2.8 2.6 i 2.7 6.1 i 6.4

-0.7 +/- 2.7 0.8 +/- 2.5

-1.8 i 2.9

-5.6 +/- 3.8

-1.4 +/- 2.4 ELW-6470 11-10-05 2.1 +/- 0.6 0.10 +/- 0.21 9.5 +/- 16.0 1.7 +/- 1.9 0.6 +/- 3.2 0.8 +/- 1.8

-0.9 +/- 1.9

-1.8 +/- 4.1 0.6 +/- 1.9

-0.9 +/- 1.8

-0.4 +/- 1.7

-1.6 +/- 2.0

-1.9 +/- 1.7 ELW-7103 12-13-05 5.6

-0.07

-17.7 0.4

-3.3

-0.2 1.5 0.9 0.5

-2.7 0.8 2.3

-0.2

+/- 0.7'

+/- 0.14

+/- 18.1 -

+/- 2.3

+/- 3.7

+/- 2.3

+/- 2.4

+/- 4.1

+/- 2.5 -

+/- 2.5

+/- 2.6

+/- 2.3 '

+/- 2.4 Req. LLD 4.0 0.5 10 30 10 10 30 15 10 10 15 30 a Ru-103 b Gross beta recount = 11.0+/-1.5 pCi/L; reanalysis result = 17.6+2.5 pCi/L.

21

POINT BEACH Lake water, analyses for tritium, strontium-89 and strontium-90.

Collection: Quarterly composites of weekly grab samples Units: pCi/L Location Period Lab Code H-3 Sr-89 Sr-90 1 st Qtr.

ELW-1 224 85 +/- 87

-0.45 +/- 0.54 0.58 +/- 0.35 E-01 (Meteorological Tower) 2nd Qtr.

3rd Qtr.

ELW-3449 ELW-5309 24 +/- 102 236 +/- 86

-0.33 +/- 0.66 0.27 +/- 0.58 0.62 +/- 0.35 0.41 +/- 0.30 4th Qtr.

ELW-7325 166+/-101

-0.19 +/- 0.77 0.53 +/- 0.36 Location Period Lab Code H-3 Sr-89 Sr-90 1st Qtr.

ELW-1225 124 +/-89

-0.55 +/- 0.60 0.71 +/- 0.38 E-05 (Two Creeks Park) 2nd Qtr.

3rd Qtr.

ELW-3450 ELW-5310 115+/-105 164+/-86 0.25 +/- 0.55

-0.12 +/- 0.63 0.27 +/- 0.27 0.30 +/- 0.35 4th Qtr.

ELW-7326 359 +/- 118 0.44 +/- 0.70 0.27 +/- 0.31 Location Period Lab Code H-3 Sr-89 Sr-90 1st Qtr.

ELW-1226 187 +/-92

-0.33 +/- 0.51 0.78 +/- 0.32 E-06 (Coast Guard Station) 2nd Qtr.

3rd Qtr.

ELW-3451 ELW-5311 35+/-102 231+/-89

-0.27 +/-0.60 0.08 +/- 0.60 0.41 +/- 0.30 0.46 +/- 0.33 4th Qtr.

ELW-7327 381 +/- 108 0.44 +/- 0.55 0.20 +/- 0.23 Location E-33 (Nature Conservancy)

Period 1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code ELW-1227 ELW-3452 ELW-5312 ELW-7328 H-3 28 +/- 85 100 +/- 104 202 +/- 88 1576 +/- 144a Sr-89 0.05 +/- 0.50

-0.45 +/- 0.71

-0.11 +/- 0.52

-0.07 +/- 0.57 Sr-90 0.26 +/- 0.29 0.53 +/- 0.33 0.39 +/- 0.29 0.37 +/- 0.25 a Repeat result = 1777+/-153 pCi/L. Monthly tritium results: October = 2 +/- 112 pCi/L; November = 3,146 +/- 189; December = 1,758 +/- 159 pC/L.

Note: pages 23 and 24 are intentionally left out.

22

POINT BEACH NUCLEAR PLANT Fish, analyses for gross beta and gamma emitting isotopes.

Location: E-13 Collection: 3x / year Units: pCilg wet I)

Sample Description and Concentration Required LLD Collection Date Lab Code Type Ratio (wet/dry wt.)

Gross Beta 03-09-05 EF-1114 Catfish 2.73 3.79 +/-0.11 03-09-05 EF-1115 Catfish 2.75 4.66 +/- 0.09 03-09-05 EF-1116 Drum 4.45 3.54 + 0.09 0.5 K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 Other Gammasa 2.96 +/- 0.65

-0.001 +/- 0.012

-0.031 +/- 0.025 0.004 +/- 0.012

-0.004 +/- 0.016 0.004 +/- 0.025

-0.001 +/- 0.014 0.066 +/- 0.025 0.000 +/- 0.010 2.80 +/- 0.54 0.001 +/- 0.015 0.034 +/- 0.025 0.003 +/- 0.014 0.015 +/- 0.014 0.017 +/- 0.030 0.003 +/- 0.015 0.036 +/- 0.017 0.007 +/- 0.011 2.56 +/- 0.72

-0.011 +/- 0.024 0.018 +/- 0.052 0.002 +/- 0.025 0.014 +/- 0.028

-0.005 +/- 0.066

-0.007 +/- 0.026 0.023 +/- 0.023

-0.019 +/- 0.021 0.13 0.26 0.13 0.13 0.26 0.13 0.15 0.5 Coilection Date Lab Code Type Ratio (wet/dry wt.)

Gross Beta 08-11-05 EF4638 Perch 3.71 4.55 +/- 0.21 08-11-05 EF-4639, 10 Trout 2.89 3.35 +/- 0.08 08-11-05 EF-4641 Sucker 3.51 K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 Other Gammasa 2.49 +/- 0.56 0.003 +/- 0.017 0.034 + 0.035 0.003 +/- 0.017

-0.002 +/- 0.021

-0.092 +/- 0.044

-0.043 +/- 0.019 0.172 +/- 0.055 /

-0.027 +/- 0.019 2.60 +/- 0.41

-0.016 +/- 0.014 0.019 +/- 0.025

-0.003 +/- 0.013 0.013 +/- 0.014

-0.018 +/- 0.035 0.008 +/- 0.011 0.048 +/- 0.016 /

-0.007 +/- 0.010 2.62 +/- 0.06 2.82 +/- 0.60

-0.004 +/- 0.014

-0.005 +/- 0.032 0.030 +/- 0.014

-0.002 +/- 0.018

-0.025 +/- 0.036

-0.001 +/- 0.010 0.031 +/- 0.015 0.010 +/- 0.013 0.5 0.13 0.26 0.13 0.13 0.26 0.13 0.15 0.5 8 Ru-103 25

POINT BEACH NUCLEAR PLANT Fish, analyses for gross beta and gamma emitting isotopes.

Location: E-1 3 Collection: 3x / year Units: pCi/L Sample Description and Concentration (pCi/g wet)

Required LLD Collection Date Lab Code Type Ratio (wet/dry wt.)

Gross Beta 12-14-05 EF-7076,7 Lake Trout 2.76 2.50 +/- 0.19 12-14-05 EF-7078 Salmon 3.56 1.73 +/- 0.06 0.5 K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-1 37 Other Gammasa 1.68 +/- 0.27

-0.016 +/- 0.009 0.009 +/- 0.018 0.003 +/- 0.008 '

0.009 +/- 0.011

-0.027 +/- 0.019 0.003 +/- 0.007 -

0.010 +/- 0.010 -,

-0.006 +/- 0.008 1.47 +/- 0.47

-0.012 +/- 0.015

-0.046 +/- 0.033 0.002 +/- 0.012 0.008 +/- 0.021 /

0.021 +/- 0.034

-0.004 +/- 0.014 t 0.008 +/- 0.014

-0.006 +/- 0.011 0.13 0.26 0.13 0.13 0.26 0.13 0.15 0.5 a Ru-103 NOTE: Page 27 is intentionally left out.

26

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SHORELINE SEDIMENT SAMPLES (Semiannual Collections)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code 4/14/2005 ESS-1 916 4/14/2005 ESS-1917 E-05 4/14/2005 ESS-1 918 Required LLD Location E-01 E-06 Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 8.35 +/- 2.05 0.062 +/- 0.084 6.00 +/- 0.61 0.016 +/- 0.013 0.079 +/- 0.024 0.28 +/- 0.031 0.20 +/- 0.042 0.51 +/- 0.24 0.32 +/- 0.081 10.34 +/- 1.87 0.053 +/- 0.087 6.29 +/- 0.61 0.017 +/- 0.013 0.111 +/-0.027 0.31 +/- 0.031 0.23 +/- 0.040 0.44 +/- 0.23 0.43 +/- 0.086 13.20 +/- 2.03 0.007 +/- 0.078 7.46 +/- 0.68 0.023 +/- 0.014 0.055 +/- 0.026 0.12 +/- 0.026 0.17 +/- 0.039 0.36 +/- 0.17 0.11 +/- 0.061 2.0 0.15 Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 4/14/2005 ESS-1 919 E-12 13.10 +/-2.28 4/14/2005 ESS-1 920 E-33

-0.048 +/- 0.093 4.52 +/- 0.53 0.025 +/- 0.015 0.195 +/- 0.034 0.53 +/- 0.039 0.52 +/- 0.056 0.95 +/- 0.29 0.55 +/- 0.106 7.42 +/- 1.73

-0.025 +/- 0.073 5.28 +/- 0.56

-0.005 +/- 0.011 0.024 +/- 0.012 0.11 +/- 0.023 0.15 +/- 0.055 0.32 +/- 0.16 0.18 +/- 0.075 2.0 0.15 28

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN SHORELINE SEDIMENT SAMPLES (Semiannual Collections)

)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code Location 10/12/2005 ESS-5783 E-01 10/12/2005 ESS-5784 E-05 10/12/2005 ESS-5785 E-06 Required LLD Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 8.79 +/- 1.75

-0.117 +/- 0.076 4.73 +/- 0.52 0.014 +/- 0.012 0.046 +/- 0.027 0.13 +/- 0.024 0.08 +/- 0.034 0.38 +/- 0.15 0.20 +/- 0.083 7.87 +/- 1.63 0.066 +/- 0.076 5.42 +/- 0.55

/ 0.013 +/- 0.012 0.068 +/- 0.022 0.16 i 0.026 0.14 +/- 0.049 0.60 +/- 0.26 0.23 +/- 0.092 12.29 +/- 1.66

-0.122 +/- 0.097 7.02 +/- 0.60 0.017 +/- 0.014 0.130 +/- 0.030 0.38 +/- 0.035 0.30 +/- 0.044 0.82 +/- 0.26 0.47 +/- 0.130 2.0 0.15 Collection Date Lab Code Location 10/12/2005 ESS-5786 E-1 2 10/12/2005 ESS-5787 E-33 Gross Beta 9.15 + 1.03 13.06 +/- 1.78 2.0 Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228

-0.023 +/- 0.077 6.96 i 0.58 0.014 +/- 0.012 /

0.051 +/-0.018 0.12 +/- 0.024 0.10 +/- 0.034 0.22 +/-0.16 0.21 +/- 0.081 0.014 +/- 0.084 9.22 +/- 0.75 0.011 +/-0.013 0.047 +/- 0.025 0.11 +/-0.027 0.10 +/- 0.040 0.08 +/- 0.19 0.17 +/- 0.101 z

1 0.15 I;

29

POINT BEACH CLEAR PLANT RADIOACTIVITY IN SOIL SAMPLES (Semiannual Collections)

Sample Description and Concentration (pCVg dry)

Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 5/25/2005 ESO-2859 E-01 29.75 +/- 2.41

-0.05 +/- 0.10 15.65

  • 0.82 0.00
  • 0.011 0.19 +/- 0.037 0.71 +/- 0.120 0.43 +/- 0.053 1.13 +/- 0.33 0.69 +/- 0.11 5/25/2005 ESO-2860 E-02 34.49 +/- 2.53 0.13 +/- 0.10 19.92 t 0.91 0.25
  • 0.039 0.24 t 0.040 0.64 +/- 0.048 0.41 t 0.054 1.16 +/-0.35 0.55 t 0.10 5/25/2005 ESO-2861 E-03 33.89
  • 2.36

-0.10 +/- 0.09 19.82 +/- 0.82 0.45

  • 0.045 0.23 +/- 0.040 0.60 +/- 0.040 0.44
  • 0.047 1.22
  • 0.31 0.66 t0.12 Required LLD 2.0 0.15 Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 5/25/2005 ESO-2862 E-04 28.53 +/- 2.30

-0.08 +/- 0.10 19.94 +/- 0.92 0.19

  • 0.035 0.19 +/- 0.035 0.57
  • 0.052 0.36
  • 0.054 0.96
  • 0.34 0.65 +/- 0.14 5/25/2005 ESO-2863 E-06 19.08 +/- 1.91 0.06 +/- 0.09 11.74 +/- 0.66 0.38 +/- 0.036 0.07 +/- 0.021 0.24
  • 0.031 0.20
  • 0.039 0.67 t 0.23 0.29 +/- 0.08 5/25/2005 ESO-2864 E-08 19.85
  • 1.94 0.04
  • 0.08 12.42 +/- 0.69 0.38
  • 0.034 0.11 +/-0.024 0.32 +/- 0.048 0.20 +/- 0.039 0.75 t 0.22 0.41 +/- 0.10 2.0 0.15 5/25/2005 ESO-2865,6 E-09 33.42 +/- 1.71 0.02 +/- 0.10 22.13 +/- 0.69 0.18 +/- 0.024 0.25 +/- 0.029 0.73 +/- 0.034 0.45 +/- 0.039 1.36 +/- 0.26 0.78 +/- 0.09 5/25/2005 ESO-2867 E-20 37.25 +/- 2.85 0.01 *0.12 17.73 +/- 0.91 0.29 t 0.049 0.18 +/- 0.032 0.56 *0.041 0.41 +/- 0.061 1.16 +/-0.32 0.52 *0.12 2.0 0.15 30

POrNTr BEACH NUCLEAR PL ANT RADIOACTIVITY IN SOIL SAMPLES (Semiannual Collections)

Sample Description and Concentration (pCi/g dry)

Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 10/28/2005 ESO-6265 E-01 24.07 t 1.76 0.18 +/-0.08 15.29

  • 0.75 0.11 +/-0.026 0.17 +/-0.035 0.51 +/- 0.039 0.43 +/- 0.047 0.99 t 0.31 0.55 t 0.10 10/28/2005 ESO-6266 E-02 34.87 +/- 2.11 0.01 +/- 0.14 22.19 +/- 1.26 0.10 +/- 0.057 0.24 +/- 0.055 0.64 +/- 0.052 0.44 t 0.082 1.11 t 0.38 0.68
  • 0.13 10/28/2005 ESO-6267 E-03 29.43 +/- 1.84 0.21
  • 0.12 20.09
  • 1.21 0.20 +/- 0.046 0.20 +/- 0.040 0.59 +/- 0.048 0.38 +/- 0.084 1.34 +/- 0.39 0.55
  • 0.12 Required LLD 2.0 0.15 Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-1 37 TI-208 Pb-2112 Bi-214 Ra-226 Ac-228 10/28/2005 ESO-6268 E-04 31.20 +/- 1.20

-0.010 +/- 0.13 17.21

  • 1.26 0.08 +/- 0.033 0.20 +/- 0.054 0.56
  • 0.052 0.43 +/- 0.070 0.89 +/- 0.38 0.64+/-0.16 10/28/2005 ESO-6269 E-06 22.75 +/- 1.77 0.15 t0.12 11.65 +/- 0.87 0.67 +/- 0.055 0.73
  • 0.036 0.21 +/- 0.033 0.21 +/- 0.069 0.58 +/- 0.28 0.30 +/-0.11 10/28/2005 ESO-6270,1 E-08 24.55 +/- 1.84

-0.04 +/- 0.08 13.85 +/- 0.53 0.33 +/- 0.027 0.11 +/- 0.022 0.33 +/- 0.055 0.23 +/- 0.031 0.62 +/- 0.19 0.33 +/- 0.08 2.0 0.15 Collection Date Lab Code Location Gross Beta Be-7 K-40 Cs-137 TI-208 Pb-212 Bi-214 Ra-226 Ac-228 10/28/2005 ESO-6272 E-09 37.26 +/- 2.850 0.24 +/- 0.11 20.98 +/- 1.01 0.22 +/- 0.039 0.23 +/- 0.049 0.64 +/- 0.052 0.39 +/- 0.056 1.12 *0.36 0.66 +/- 0.12 10/28/2005 ESO-6273 E-20 25.12 +/-3.77 0.00 +/- 0.12 13.60 +/- 0.97 0.24 +/- 0.050 0.16 +/-0.039 0.45 +/- 0.044 0.28 +/- 0.058 1.01 +/- 0.37 0.53 +/- 0.14 2.0 0.15 31

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCi/g wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-1 34 Cs-137 Other Gammasa E-01 5/25/2005 EG-2848 5.10 7.13 +/- 0.17 0.86 +/- 0.26 5.09 +/- 0.55 0.001 +/- 0.009 0.003 +/- 0.008

-0.012 +/- 0.013

-0.005 +/- 0.014 E-02 5/25/2005 EG-2849 3.17 5.83 +/- 0.13 0.90 +/- 0.15 3.95 +/- 0.34

-0.017 +/- 0.011

-0.003 +/- 0.010

-0.005 +/- 0.009 0.002 +/- 0.009 E-03 5/25/2005 EG-2850 5.88 4.85 +/- 0.10 0.41 +/- 0.17 6.01 +/- 0.50

-0.007 +/- 0.008 0.003 +/- 0.011 0.002 +/- 0.011

-0.003 +/- 0.011 Req. LLD 0.25 0.060 0.060 0.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Other Gammasa E-04 5/25/2005 EG-2851 4.15 8.70 +/- 0.17 0.71 +/- 0.23 5.38 +/- 0.49 0:005 +/- 0.009 0.005 +/- 0.012

-0.004 +/- 0.011

-0.003 +/- 0.013 E-06 5/25/2005 EG-2852 4.31 5.38 +/- 0.11 0.50 +/- 0.16 4.39 +/- 0.42 0.005 i 0.010

-0.002 +/- 0.011 0.040 +/- 0.019 0.009 +/- 0.008 E-08 5/25/2005 EG-2853 3.58 8.25 +/- 0.17 0.45 +/- 0.20 6.38 +/- 0.57 0.002 +/- 0.008 0.005 +/- 0.012 0.013 +/- 0.013 0.014 +/- 0.012 Req. LLD 0.25 0.060 0.060 0.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Other Gammasa E-09 5/25/2005 EG-2854 4.17 7.12 +/- 0.14 0.68 +/- 0.14 5.25 +/- 0.42 0.009 +/- 0.011 0.002 +/- 0.011 0.004 +/- 0.010 0.002 +/- 0.009 E-20 5/25/2005 EG-2855 5.10 7.38 +/- 0.15 0.61 +/- 0.18 6.21 +/- 0.41

-0.009 +/- 0.008 0.002 +/- 0.010 0.000 +/- 0.008 0.002 +/- 0.009 Req. LLD 0.25 0.060 0.060 0.080 0.060 a See Introduction.

32

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCi/g wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Other Gammasa E-01 7/29/2005 EG-4395 2.93 9.21 i 0.23 1.95 +/- 0.31 5.37 +/- 0.45

-0.002 +/- 0.012 0.000 + 0.011

-0.004 +/- 0.012 0.010 + 0.011 E-02 7/28/2005 EG-4396 3.07 7.98 +/- 0.20 1.60 +/- 0.18 5.26 +/- 0.41

-0.009 +/- 0.011

-0.002 +/-0.011 0.001 +/-0.011 0.010 +/- 0.013 E-03 7/28/2005 EG-4397 3.81 8.41 +/- 0.20 1.22 +/- 0.18 6.62 +/- 0.48

-0.004 +/- 0.008

-0.001 +/- 0.010

-0.004 +/- 0.008 0.001 +/- 0.009 Req. LLD 0.25 0.060 0.060 0.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-13.1-Cs-1 34 Cs-1 37 Other Gammasa E-04 7/28/2005 EG-4398 2.61 9.63 +/- 0.38 1.46 +/- 0.22 6.02 +/- 0.48

-0.002 +/- 0.008

-0.001 +/- 0.011

-0.004 +/- 0.008

-0.007 +/- 0.009 E-06 7/29/2005 EG-4399 2.48 6.66 +/- 0.24 1.20 +/- 0.29 3.82 +/- 0.58 0.015 +/- 0.010

-0.002 +/- 0.016 0.035 +/- 0.018

-0.020 +/- 0.018 E-08 7/28/2005 EG-4400 2.26 9.36 +/- 0.34 Req. LLD 0.25 1.39 5.33 0.002

-0.006

  • 0.009 0.002

+/- 0.25

+/- 0.60

+/- 0.010

+/- 0.010

+/- 0.013

+/- 0.014

- 0.060 0.060 0.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-1 34 Cs-1 37 Other Gammasa E-09 7/28/2005 EG-4401 2.57 8.86 +/- 0.37 E-20 7/29/2005 EG-4402 2.10 8.97

  • 0.35 1.14 +/- 0.31 7.38 +/- 0.73

-0.014 +/- 0.014

-0.002 +/- 0.016 0.020 +/- 0.015 0.017 + 0.020 1.17 5.33

-0.003 0.007

-0.001

-0.006

+/- 0.28

+/- 0.59

+/- 0.011

+/- 0.012

+/- 0.014

+/- 0.015 i:.

t I

I :

I Req. LLD 0.25 0.060 0.060 0.080 0.060 a See Introduction.

33

)

POINT BEACH NUCLEAR PLANT RADIOACTIVITY IN VEGETATION SAMPLES (Tri-Annual Collections)

Sample Description and Concentration (pCi/g wet)

Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-137 Other Gammasa E-01 10/28/2005 EG-6210 2.29 8.79 +/- 0.27 E-02 10/28/2005 EG-6211 2.44 7.20 +/- 0.26 E-03 10/28/2005 EG-6212 3.03 9.20 +/- 0.22 Req. LLD 0.25 3.66 +/- 0.12 '

3.16 +/- 0.17 4.26 +/- 0.17 3.40 +/- 0.17

-0.019 +/- 0.005

-0.005 +/- 0.005

-0.065 +/- 0.005 /

-0.005 +/- 0.004

-0.004 +/- 0.005 0.001 +/- 0.004

-0.002 +/- 0.004 0.003 +/- 0.004 It 2.63 6.20

-0.006

-0.002 0.005 0.007 t0.19 "

i 0.28

+/- 0.006

+/- 0.005

+/- 0.006

+/- 0.007 0.060 0.060 0.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-134 Cs-1 37 Other Gammasa E-04 10/28/2005 EG-6213 2.72 7.34 +/- 0.19 3.28 +/- 0.13 -

4.31 +/-0.180 0.020 +/- 0.004 0.000 +/- 0.003 0.002 +/- 0.004

-0.001 +/- 0.004 E-06 10/28/2005 EG-6214 2.62 4.30 +/- 0.14 2.68 +/- 0.14 2.23 +/- 0.140 0.001 +/-0.004 0.000 +/- 0.003 0.015 +/- 0.007

-0.002 +/- 0.004 E-08 10/28/2005 EG-6215 2.27 7.76 +/- 0.19 4.61 +/- 0.23 4.27 +/- 0.180 0.023 +/- 0.005

-0.012 +/- 0.004 0.002 i 0.005

-0.002 +/- 0.004 Req. LLD 0.25 0.060 0.060 D.080 0.060 Location Collection Date Lab Code Ratio (wet/dry)

Gross Beta Be-7 K-40 1-131 Cs-1 34 Cs-1 37 Other Gammasa E-09 10/28/2005 EG-6216 2.28 7.62 +/- 0.21 2.64 +/- 0.09 3.98 +/- 0.15

-0.012 +/- 0.004

-0.028 +/- 0.004 0.001 +/- 0.004 0.002 +/- 0.003 E-20 10/28/2005 EG-6217 Req. LLD 2.82 6.55 +/- 0.19 0.25

/

2.02 +/-0.18 3.86 t 0.25

-0.020 +/- 0.006

-0.003 +/- 0.005 0.001 +/- 0.007 0.003 +/- 0.007 0.060 0.060 0.080 0.060 a See Introduction.

34

POINT BEACH NUCLEAR PLANT Aquatic Vegetation, analyses for gross beta and gamma emitting isotopes.

Collection: Semiannual Units: pCVg wet Sample Description and Concentration Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-1 34 Cs-137 Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-I 34 Cs-1 37 Collection Date Lab Code Location Ratio (wet wt./dry wt.)

Gross Beta Be-7 K-40 Co-58 Co-60 Cs-I 34 Cs-1 37 06-02-05 ESL-3039 E-05 7.99 2.52 +/- 0.08 0.33 +/- 0.22 0.97 +/- 0.53

-0.018 +/- 0.022 0.012 +/- 0.025 0.027 +/- 0.027

-0.004 +/- 0.028 08-04-05 ESL-4472 E-05 8.39 5.01 +/- 0.17 0.32 +/- 0.15-2.29 +/- 0:68 0.003 +/- 0.01.8

-0.008 +/- 0.021 0.016 +/- 0.019

-0.001 +/- 0.018 10-06-05 ESL-5623 E-05 3.17 6.91 +/- 0.58 1.55 +/- 0.36 3.44 +/- 0.58

-0.006 +/- 0.012 0.006 +/- 0.016 0.000 +/- 0.013 0.041 +/- 0.019 06-02-05 ESL-3040 E-12 3.13 6.17 +/- 0.58 0.82 +/- 0.17 2.67 +/- 0.36 0.005 +/- 0.010 0.007 +/- 0.011 0.017 +/- 0.013 0.020 +/- 0.012 08-04-05 ESL-4473,4 E-12 5.08 5.01 +/- 0.32 0.59 +/- 0.22

- 2.82 +/- 0:49 0.005 +/- 0.014

-0.019 +/- 0.027 0.004 +/- 0.015 0.012 +/- 0.013 10-06-05 ESL-5624 E-Z E-)

2.93 5.58 +/- 0.54 0.64 +/- 0.26 1.74 +/- 0.37

-0.004 +/- 0.011 0.005 +/- 0.011

-0.004 +/- 0.009 0.013 +/- 0.013 Required LLD 0.25 0.25 0.25 0.25 0.25 Required LLD 0.25 0.25 0.25 0.25 0.25 Required LLD 0.25 0.25 0.25 0.25 0.25 35

POINT BEACH NUCLEAR PLANT AMBIENT GAMMA RADIATION (TLD) 1st. Quarter, 2005 Date Annealed:

12-15-04 Days in the field 90 Date Placed:

01-04-05 Days from Annealing Date Removed:

04-04-05 to Readout:

124 Date Read:

04-18-05 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-14 E-1 5 E-16 E-17 E-1 8 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 14.1 +/- 0.9 16.6 +/- 0.1 17.8 +/- 1.2 15.3 +/- 1.2 17.3 +/- 1.0 15.7 +/- 1.0 15.4 +/- 1.1 15.0 +/- 0.8 17.2 +/- 0.6 13.4 i 0.2 16.8 +/- 0.8 17.2 +/- 0.7 16.1 +/-0.6 16.9 +/- 0.6 16.3 +/- 0.9 16.9 +/- 1.3 16.5 +/- 0.4 16.9 +/- 0.6 15.1 +/-0.4 14.4 +/- 0.4 15.4 +/- 0.3 12.7 +/- 0.3 14.6 +/- 0.9 14.7 +/- 0.6 15.9 +/- 0.7 16.1 +/- 0.7 15.5 +/- 1.0 12.4 +/- 0.4 15.3 +/-0.7 8.9 +/- 1.2 11.4 +/- 0.8 12.6 +/- 1.4 10.1 +/- 1.4 12.1 +/- 1.3 10.5 +/- 1.3 10.2 +/- 1.3 9.8 +/- 1.1 12.0 +/- 1.0 8.2 +/- 0.8 11.6 +/- 1.1 12.0 +/- 1.0 10.9 +/- 1.0 11.7 +/- 1.0 11.1 +/-1.2 11.7 +/- 1.5 11.3 +/-0.9 11.7 +/- 1.0 9.9 0 0.9 9.2 +/- 0.9 10.2 +/- 0.8 7.5 +/- 0.8 9.4 +/- 1.2 9.5 +/- 1.0 10.7 +/- 1.0 10.9 +/- 1.0 10.3 +/- 1.3 7.2 +/- 0.9 10.1 +/-1.0 0.69 +/- 0.09 0.88 +/- 0.06 0.98 +/- 0.11 0.78 +/- 0.11 0.94 +/- 0.10 0.81 +/- 0.10 0.79 +/- 0.10 0.76 +/- 0.09 0.93 +/- 0.08 0.63 +/- 0.06 0.90 +/- 0.09 0.93 +/- 0.08 0.84 +/- 0.08 0.91 +/- 0.08 0.86 +/- 0.09 0.91 +/- 0.12 0.88 +/- 0.07 0.91 +/- 0.08 0.77 +/- 0.07 0.71 +/- 0.07 0.79 +/- 0.06 0.58 +/- 0.06 0.73 +/- 0.09 0.74 +/- 0.08 0.83 +/- 0.08 0.84 +/- 0.08 0.80 +/- 0.10 0.56 +/- 0.07 0.78 +/- 0.08 Control E-20 90 Mean+/-s.d.

15.6 +/- 1.4 10.4 +/- 1.4 0.81 +/- 0.11 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exnosure 12-15-04 03-16-05 01-25-05 04-18-05 Total mR 6.4 +/- 0.6 4.3 +/- 0.3 6.0 +/- 0.2 4.3 +/- 0.3 36

POINT BEACH NUCLEAR PLANT

)

AMBIENT GAMMA RADIATION (TLD) 2nd Quarter, 2005 Date Annealed:

03-16-05 Days in the field 93 Date Placed:

04-04-05 Days from Annealing Date Removed:

07-06-05 to Readout:

118 Date Read:

07-12-05 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-14 E-1 5 E-16 E-17 E-18 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93

  • 93 93 93 93 93 93 93 93 93 93 93 16.8 +/- 1.4 21.8 +/- 1.1 22.6 +/- 1.8 18.6 +/- 0.8 20.7 +/- 0.7 17.5 +/-0.6 17.0 i0.6 17.8 +/-0.8 20.8 +/- 1.4 14.5 i 1.1 18.6 +/- 0.4 24.9 +/- 2.1 18.3 +/- 0.3 19.4 +/- 1.2 20.2 +/- 0.7 20.4 +/- 0.4 21.2 +/-0.7 18.9 +/-0.4-21.0 +/- 1.2 16.2 i0.6 18.9 i 0.6 14.6 +/- 0.5 16.6 +/- 0.6 18.3 i0.4 21.0 +/- 1.5 20.2 +/- 1.3 18.7 +/-0.7 14.8 +/- 0.3 12.6 +/- 1.5 17.6 +/- 1.2 18.4 +/- 1.9 14.4 +/- 0.9 16.5 +/- 0.8 13.3 +/-0.7 12.8 +/- 0.7 13.6 +/- 0.9 16.6 +/- 1.5 10.3 +/- 1.2 14.4 +/-0.6 20.7 +/- 2.1 14.1 +/-0.5 15.2 +/- 1.3 16.0 +/- 0.8 16.2 +/- 0.6 17.0 +/- 0.8 14.7 +/- 0.6 16.8 +/- 1.3 12.0 +/- 0.7 14.7 +/- 0.7 10.4 +/- 0.7 12.4 +/- 0.7 14.1 +/-0.6 16.8 +/- 1.6 16.0 +/- 1.4 14.5 +/- 0.8 10.6 +/- 0.5 0.95 +/-0.11 1.32 +/- 0.09 1.38 +/- 0.14 1.08 +/- 0.07 1.24 +/- 0.06 1.00 +/- 0.06 0.96 +/- 0.06 1.02 +/- 0.07 1.25 +/- 0.11 0.78 +/- 0.09 1.08 i 0.05 1.56 +/- 0.16 1.06 +/- 0.04 1.14 +/- 0.10 1.20 +/- 0.06 1.22 +/- 0.05 1.28 +/- 0.06 1.11 +/- 0.05 1.26 +/- 0.10 0.90 +/- 0.06 1.11 +/- 0.06 0.78 +/- 0.05 0.93 +/- 0.06 1.06 +/- 0.05 1.26 +/- 0.12 1.20 +/- 0.10 1.09 t 0.06 0.80 +/- 0.04 Control E-20 93 18.6 +/- 1.8 14.4 +/- 1.9 1.08 +/- 0.14 Mean+/-s.d.

18.9 +/- 2.4 14.7 +/- 2.4 1.11 +/- 0.18 In-Transit Exposure Date Annealed Date Read ITC-1 ITC-2 03-16-05 1

04-18-05 1

Total mR 4.3 +/- 0.3 4.3 +/- 0.3 06-16-05 07-13-05 4.5 +/- 0.1 3.7 +/-0.1 37

POINT BEACH NUCLEAR PLANT 1

AMBIENT GAMMA RADIATION (TLD) 3rd Quarter, 2005 Date Annealed:

06-16-05 Days in the field 92 Date Placed:

07-06-05 Days from Annealing Date Removed:

10-06-05 to Readout:

119 Date Read:

10-13-05 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-12 E-14 E-1 5 E-16 E-1 7 E-18 E-22 E-23

  • E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 92 15.5 +/- 1.1 17.8 +/- 0.2 22.3 +/- 1.4 18.1 +/-1.4 20.6 +/- 0.9 16.8 +/- 0.9 17.3 +/- 1.2 17.9 +/- 1.4 20.2 +/- 0.6 14.1 +/-0.7 18.9 +/- 0.7 20.9 +/- 0.7 18.4 +/-0.5 19.5 +/- 0.6 20.2 +/- 0.9 19.8 +/- 1.4 19.9 +/- 0.4 18.5 +/- 0.8 18.0 +/- 0.2 16.7 +/- 0.8 17.3 +/- 0.3 13.0 +/- 0.2 16.5 +/- 0.9 16.8 +/- 0.6 19.2 +/- 0.7 17.9 +/- 0.6 19.0 +/- 1.6 13.3 +/- 0.4 17.2 +/- 0.9 18.0 +/- 2.2 11.6 +/- 1.2 13.9 +/-0.4 18.4 +/- 1.4 14.2 +/- 1.4 16.7 i 1.0 12.9 +/- 1.0 13.4 i 1.2 14.0 +/- 1.4 16.3 +/-0.7 10.2 i 0.8 15.0 +/- 0.8 17.0 i 0.8 14.5 +/- 0.6 15.6 +/- 0.7 16.3 +/- 1.0 15.9 i 1.4 16.0 +/- 0.5 14.6 +/-0.9 14.1 +/-0.4 12.8 t 0.9 13.4 +/- 0.5 9.1 i0.4 12.6 i 1.0 12.9 +/- 0.7 15.3 +/- 0.8 14.0 t 0.7 15.1 i1.6 9.4 +/- 0.5 0.88 +/- 0.09 1.06 +/- 0.03 1.40 +/- 0.11 1.08 +/- 0.11 1.27 +/- 0.07 0.98 +/- 0.07 1.02 +/- 0.10 1.07 +/- 0.11 1.24 +/- 0.05 0.78 +/- 0.06 1.14 +/- 0.06 1.30 +/- 0.06 1.11 +/- 0.05 1.19 +/- 0.05 1.24 +/- 0.07 1.21 +/- 0.11 1.22 +/- 0.04 1.11 +/-0.07 1.07 +/- 0.03 0.98 +/- 0.07 1.02 +/- 0.03 0.69 +/- 0.03 0.96 +/- 0.07 0.98 +/- 0.05 1.17 +/- 0.06 1.07 +/- 0.05 1.15 +/- 0.12 0.72 +/- 0.04 Control E-20 92 13.3 +/- 1.0 1.01 +/- 0.07 14.1 i 2.2 1.07 +/- 0.17 Mean+/-s.d.

Date Annealed Date Read ITC-1 ITC-2 In-Transit Exposure 06-16-05 09-20-05 07-13-05 10-13-05 Total mR 4.5 +/-0.1 3.7 +/- 0.1 3.6 +/- 0.3 3.7 +/- 0.1 38

POINT BEACH NUCLEAR PL AMBIENT GAMMA RADIATION (TLD) 4th Quarter, 2005 Date Annealed:

09-20-05 Days in the field 91 Date Placed:

10-06-05 Days from Annealing Date Removed:

01-05-06 to Readout:

112 Date Read:

01-10-06 Days in Location Field Total mR Net mR Net mR per 7 days Indicator E-1 E-2 E-3 E-4 E-5 E-6 E-7 E-8 E-9 E-1 2 E-14 E-1 5 E-1 6 E-1 7 E-1 8 E-22 E-23 E-24 E-25 E-26 E-27 E-28 E-29 E-30 E-31 E-32 E-38 E-39 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 91 16.3 +/- 1.4 22.5 +/- 1.4 22.3 +/- 1.8 18.2 +/-0.5 20.3 +/- 1.0 17.5 +/- 0.5 16.6 +/- 0.5 17.6 +/- 0.8 20.1 +/-1.4 14.6 +/- 1.2 18.0 +/- 0.3 22.7 +/- 0.5 18.4 +/- 1.0 18.6 +/- 0.9 20.0 +/- 0.3 19.9 +/-0.5 21.1 +/-0.6 18.9 iO.7 19.8 +/-0.3 16.6 +/-0.4 18.7 +/- 0.7 14.2 +/- 0.3 19.6 +/- 0.8 18.5 +/- 0.5 20.8 +/- 1.2 NDa 18.6 +/-0.5 16.6 +/-0.4 18.0 i 1.7 12.7 +/- 1.5 18.9 +/- 1.5 18.7 +/- 1.9 14.6 +/- 0.8 16.7 +/- 1.2 13.9 +/- 0.8 13.0 +/- 0.8 14.0 +/- 1.0 16.5 +/- 1.5 11.0 +/- 1.3 14.4 +/- 0.7 19.1 +/-0.8 14.8 +/- 1.2 15.0 +/- 1.1 16.4 +/- 0.7 16.3 +/- 0.8 17.5 +/- 0.8 15.3 +/- 0.9 16.2 +/- 0.7 13.0 +/- 0.7 15.1 +/-0.9 10.6 +/- 0.7 16.0 +/- 1.0 14.9 +/- 0.8 17.2 +/- 1.3 15.0 +/- 0.8 13.0 + 0.7 14.4 +/- 1.8 0.98 +/- 0.12 1.45 +/- 0.12 1.44 +/- 0.15 1.12 +/- 0.06 1.28 +/- 0.09 1.07 +/- 0.06 1.00 +/- 0.06 1.08 +/- 0.08 1.27 +/- 0.12 0.85 +/- 0.10 1.11 +/-0.05 1.47 +/- 0.06 1.14 +/- 0.09 1.15 +/- 0.08 1.26 +/- 0.05 1.25 +/- 0.06 1.35 i 0.06

  • 1.18 +/-0.07 1.25 +/- 0.05 1.00 +/- 0.05 1.16 i0.07 0.82 i 0.05 1.23 +/- 0.08 1.15 +/- 0.06 1.32 +/- 0.10 1.15 0 0.06 1.00 +/- 0.05 1.11 i0.14 Control E-20 91 Mean+/-s.d.

18.8 +/-2.1 15.2 +/-2.1 1.17 +/- 0.16 Date Annealed Date Read ITC-1 ITC-2 In-Transit Exgosure 09-20-05 12-14-05 10-13-05 01-10-06 Total mR 3.6 +/- 0.3 3.7 +/-0.1 3.8 +/- 0.4 3.3 +/- 0.3 a "ND" = No data; TLD missing in field.

39

Enironmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road

  • Northbrook, IL 60062-2310 ph. (847) 564-0700
  • fax (847) 5644517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January, 2005 through December, 2005

Appendix A Interlaboratory Comparison Proaram Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

The results in Table A-2 list results for thermolumiriescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house 'spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house 'blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 list results of the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the-sum of the errors. Data for previous years available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Attachment A lists acceptance criteria for 'spiked" samples.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR 'SPIKED-SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSES" One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCi/liter

> 100 pCi/liter or kg 5% of known value Strontium-89b 5 to 50 pCi/liter or kg 5.0 pCi/liter

> 50 pCi/liter or kg 10% of known value Strontium-90b 2 to 30 pCi/liter or kg 5.0 pCi/liter

> 30 pCi/liter or kg 10% of known value Potassiumr40 2 0.1 gAiter or kg 5% of known value Gross alpha s 20 pCiAiter 5.0 pCi/liter

> 20 pCi/liter 25% of known value Gross beta 5 100 pCi/liter 5.0 pCi/liter

> 100 pCi/liter 5% of known value Tritium 5 4,QQ0 pCi/liter.

1a = (pCi/liter) 169.85 x (known)00933

> 4,000 pCi/liter 10% of known value Radium-226,-228 2 0.1 pCi/liter 15% of known value Plutonium a 0.1 pCi/liter, gram, or sample 10% of known value lodine-131, 5 55 pCi/liter 6.0 pCi/liter Iodine-129b

> 55 pCi/liter 10% of known value Uranium-238, 5 35 pCi/liter 6.0 pCi/liter Nickel-63b

> 35 pCi/liter 15% of known value Technetium-99b Iron-55b 50 to 100 pCi/liter 10 pCi/liter

> 100 pCi/liter 10% of known value Othersb 20% of known value

' From EPA publication, 'Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERAr.

Concentration (pCiQL)

Lab Code Date Analysis Laboratory ERA Control Resultb Resultc Limits Acceptance STW-1051 STW-1051 STW-1052 STW-1052 STW-1052 STW-1052 STW-1052 STW-1053 STW-1053 STW-1054 STW-1054 STW-1054 STW-1055 STW-1055 STW-1056 STW-1056 STW-1056 STW-1056 STW-1056 STW-1057 STW-1057 STW-1058 STW-1059 STW-1059 STW-1059 STW-1060 STW-1067 STW-1067 STW-1068 STW-1068 STW-1068 STW-1068 STW-1068 STW-1069 STW-1069 STW-1070 STW-1070 STW-1070 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02115/05 02/15/05 02/15/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-133 Co-60 Cs-1 34 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-34 Cs-37 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium 28.0 i 1.2 25.1 +/-0.7 52.9 i 2.8 54.4 i 0.4 67.7 i 1.8 39.6 i 1.8 159.7 +/- 3.0 55.1 +/- 1.8 46.8 +/- 1.3 13.7 +/- 1.5 13.3 +/- 0.6 5.1 +/-0.2 45.1 +/- 4.1 7.5 +/- 0.9 87.1 +/-2.0 38.4 +/- 0.8 75.3 +/- 0.7 201.0 +/- 8.4 130.0 +/- 6.7 42.7 +/- 2.9 34.0 +/- 0.4 14.7 +/- 0.5 6.6 +/- 0.1 19.3 +/- 0.7 9.6 +/- 0.1 24100.0 +/- 109.0 29.1 +/- 3.0 36.0 +/- 0.6 107.0 +/- 1.7 15.2 +/- 0.2 89.1 +/-0.3 72.1 +/- 1.0 67.4 +/- 1.4 44.3 +/- 1.5 58.4 +/- 2.1 16.6 +/- 1.5 6.2 +/- 0.3 4.5 +/- 0.1 29.4 24.4 53.4 56.6 64.9 40.2 161.0 67.9 51.1 14.1 13.7 5.0 41.3 5.9 88.4 37.0 78.6 194.0 118.0 37.0 34.2 15.5 7.6 18.9 10.1 24400.0 28.0 33.8 106.0 13.5 92.1 72.7 65.7 55.7 61.3 16.6 6.2 4.5 20.7 - 38.1 15.7 - 33.1 44.2 - 62.6 47.9 - 65.3 56.2 - 73.6 31.5 - 48.9 133.0 - 189.0 38.5 - 97.3 38.5 - 97.3 10.4 - 17.8 7.8 - 19.6 0.0 - 10.2 32.6 - 50.0 0.0 - 14.6 73.1 - 104.0 28.3 - 45.7 69.9 - 87.3 184.0 - 218.0 97.6 - 138.0 21.0 - 53.0 25.5 - 42.9 10.3 - 20.7 5.6 - 9.5 10.7 - 27.1 4.9 - 15.3 20200.0 - 28600.0 19.3 - 36.7 25.1 - 42.5 87.7 - 124.0 4.8 - 22.2 83.4 - 101.0 64.0 - 81.4 54.3 - 77.1 31.6 - 79.8 44.0 - 78.6 12.3 - 20.9 3.5 - 8.9 0.0 - 9.7 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Al-1

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)".

Concentration (pCIL)

Lab Code Date Analysis Laboratory ERA Control ResultP Resultc Limits Acceptance STW-1072 11/15/05 Sr-89 20.6 +/-0.4 19.0 10.3 -27.7 Pass STW-1072 11/15/05 Sr-90 15.0 +/-0.3 16.0 7.3 -24.7 Pass STW-1073 11/15/05 Ba-133 31.8 +/- 1.8 31.2 22.5 - 39.9 Pass STW-1073 11/15/05 Co-60 85.0 +/- 1.4 84.1 75.4 - 92.8 Pass STW-1073 11/15/05 Cs-134 37.2 +/-2.1 33.9 25.2 -42.6 Pass STW-1073 11/15/05 Cs-137 27.8 +/-0.7 28.3 19.6 -37.0 Pass STW-1073 11/15/05 Zn-65 109.0 +/- 1.0 105.0 86.8 - 123.0 Pass STW-1074 d 11/15/05 Gr. Alpha 41.1 +/- 1.2 23.3 13.2 -33.4 Fail STW-1074 11/15/05 Gr. Beta 42.7 +/-0.5 39.1 30.4 -47.8 Pass STW-1075 11/15/05 1-131 20.5 +/-0.6 17.4 12.2 -22.6 Pass STW-1076 11/15/05 Ra-226 7.8 +/- 0.6 8.3 6.2 - 10.5 Pass STW-1076 e 11/15/05 Ra-228 5.5 +/- 0.6 3.5 2.0 - 5.0 Fail STW-1076 11/15/05 Uranium 15.5 +/-0.3 16.1 10.9 -21.3 Pass STW-1077 11/15/05 H-3 12500.0 +/- 238.0 12200.0 10100.0 - 14300.0 Pass

  • Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

c Results are presented as the known values, expected laboratory precision (I sigma, I determination) and control limits as provided by ERA.

dThe original samples were calculated using an Am-241 efficiency. The samples were spiked with Th-232. Samples were recounted and calculated using the Th-232 efficiency. Results of the recount: 27.01 +/- 2.35 pCilL.

'Decay of short-lived radium daughters contributed to a higher counting rate. Delay of counting for 100 minutes provided better results.

The reported result was the average of the first cycle of 100 minutes, the average of the second cycle counts was 4.01 pCi/L A11-2

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).

mR Lab Code Date Known Lab Result Control Description Value

+/- 2 sigma Limits Acceptance Environmental. Inc.

2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 30 cm 60 cm 60 cm 90 cm 90 cm 120 cm 120 cm 150 cm 180 cm 55.01 13.75 13.75 6.11 6.11 3.44 3.44 2.2 1.53 64.02 +/- 2.86 15.43 +/- 1.02 14.98 +/- 0.80 6.24 +/- 0.16 5.45 +/- 0.48 3.50 +/- 0.35 3.15 +/- 0.18 2.31 +/-0.25 1.65 +/- 0.41 38.51 - 71.51 9.63 - 17.88 9.63 - 17.88 4.28 - 7.94 4.28 - 7.94 2.41 - 4.47 2.41 - 4.47 1.54 - 2.86 1.07 - 1.99 Pass Pass Pass Pass Pass Pass Pass Pass Pass Environmental. Inc.

2005-2 2005-2 2005-2 2005-2 2005-2 2005-2 2005-2 2005-2 2005-2 9/12/2005 9/12/2005 9/12/2005

  • 9/12/2005 9/12/2005 9/12/2605 9/12/2005 9/12/2005 9/12/2005 30 cm 60 cm 75 cm
  • 90 cm 90 cm 120 cm 150 cm 150 cm 180 cm 54.84 13.71 8.77 6.09 6.09 3.43 2.19 2.19 1.52 59.30 +/- 2.66 17.55 +/- 1.30 8.24 +/- 0.38 5.94 +/- 0.49 5.93 +/- 0.37 3.42 +/- 0.18 1.71 +/- 0.14 1.87 +/- 0.27 1.58 +/- 0.99 38.39 - 71.29 9.60 - 17.82 6.14 - 11.40 4.26 - 7.92 4.26 - 7.92 2.40 - 4.46 1.53 - 2.85 1.53 - 2.85 1.06 - 1.98 Pass Pass Pass Pass Pass Pass Pass Pass Pass A2-1

TABLE A-3. In-House 'Spike" Samples Concentration (pCi/L)8 Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 C Activity Limits d Acceptance W-11105 W-11105 SPW-764 SPAP-766 STW-2887 W-30105 W-30105 1/11/2005 1/11/2005 2/18/2005 2/18/2005 2/28/2005 3/1/2005 3/1/2005 Gr. Alpha Gr. Beta H-3 Gr. Beta Tc-99 Gr. Alpha Gr. Beta 24.05 +/- 1.01 61.59 +/- 1.11 77595.00 +/- 764.00 416.08 +/- 5.52 32.91 +/- 1.23 25.22 +/- 0.45 62.27 +/- 0.48 20.08 65.70 80543.00 463.00 32.98 20.08 65.73 10.04 - 30.12 55.70 - 75.70 64434.40 - 96651.60 370.40 - 509.30 20.98 - 44.98 10.04 - 30.12 55.73 - 75.73 Pass Pass Pass Pass Pass Pass Pass SPW-1836 SPW-1836 SPMI-1838 SPMI-1838 SPMI-1838 SPMI-1838 SPMI-1838 SPMI-1838 SPVE-1932 SPCH-1935 SPAP-1966 SPAPR-966 SPAP-1 966 SPAP-1968 SPAP-1968 SPW-2098 SPW-2922 SPW-2922 SPW-2922 SPW-2922 SPAP-2892 SPW-2895 w-60105 w-60105 SPF-3089 SPF-3089 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/18/2005 4/18/2005 4/18/2005

.4/18/2005 4/18/2005 4/1i8/2005 4/18/2005 4/26/2005 5/31/2005 5/31/2005 5/31/2005 5/31/2005 6/1/2005 6/1/2005 6/1/2005 6/1/2005 6/7/2005 6/7/2005 1-131 109.79 +/- 0.94 1-131(G) 110.25 +/- 9.68 Cs-134 25.94 +/- 1.28 Cs-137 59.31 +/- 3.66 1-131 97.71 +/- 0.81 1-131(G) 109.45 +/- 3.06 Sr-89 104.44 +/-2.89 Sr-90 8.97 +/- 0.79 1-131 (G) 1.00 +/- 0.04 1-131 382.40 +/- 14.95 Cs-134 52.10 +/- 7.27 Cs-1 34 57.28 +/- 13.47 Cs-1 37 124.68 +/- 18.41 Cs-134 52.10 +/- 7.27 Cs-137 116.79 +/- 14.00 Fe-55 2565.20 +/- 63.66 Cs-134

'27.01 +/- 1.09 Cs-I 34 65.38 +/- 2.92 Sr-89 107.90 +/- 3.60 Sr-90 11.11 +/- 1.13 Gr. Beta 420.32 +/- 5.55 H-3 75271.00 +/- 724.00 Gr. Alpha 23.69 +/- 0.52 Gr. Beta 60.08 +/- 0.57 Cs-1 34 1.08 +/- 0.05 Cs-137 2.54 +/- 0.10 106.30 106.30 26.60 60.90 106.30 106.30 108.20 7.53 0.73 328.64 53.35 53.35 121.77 53.35 121.77 3017.60 25.54 60.71 113.90 6.90 448.00 78676.00 20.08 65.73 1.02 2.43 85.04 - 127.56 95.67 - 116.93 16.60 - 36.60 50.90 - 70.90 85.04 - 127.56 95.67 - 116.93 86.56 - 129.84 0.00 - 17.53 0.44 - 1.02 262.91 - 394.37 43.35 - 63.35 43.35 - 63.35 109.59 - 133.95 43.35 - 63.35 109.59 - 133.95 2414.08 - 3621.12 15.54 - 35.54 50.71 - 70.71 91.12 - 136.68 0.00 - 16.90 358.40 - 492.80 62940.80 - 94411.20 10.04 - 30.12 55.73 - 75.73 0.61 - 1.43 1.46 - 3.40 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass SPW-SPW-47731 SPW-47732 SPW-4775 SPMI-4834 SPMI-4834 SPMI-4834 SPMI-4834 7/1/2005 8/24/2005 8/24/2005 8/24/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 Ni-63 C-14 C-14 Fe-55 Cs-134 Cs-137 Sr-89 Sr-90 20.57 +/- 1.10 2112.30 +/- 9.13 2294.10 +/- 10.37 2633.50 +/- 62.40 49.27 +/- 4.68 58.17 +/- 8.18 66.39 +/- 3.13 11.15 +/- 1.13 16.75 2370.80 2370.80 2777.50 47.02 60.37 65.90 9.60 10.05 - 23.45 1422.48 - 3319.12 1422.48 - 3319.12 2222.00 - 3333.00 37.02 - 57.02 50.37 - 70.37 52.72 - 79.08 0.00 - 19.60 Pass Pass Pass Pass Pass Pass Pass Pass A3-1

TABLE A-3. In-House "Spike" Samples 1

Concentration (pCi/L)

Lab Code Date Analysis Laboratory results Known Control 2s, n=1 b Activity Limitsc Acceptance SPW-4836 SPW-4836 SPW-4836 SPW-4836 SPW-5014 W-90705 W-90705 SPW-5237 SPW-5508 SPW-6019 SPF-6293 SPF-6293 SPAP-6309 SPAP-6309 SPAP-6311 SPW-6451 W-120105 W-120105 SPW-7440 SPW-7440 SPMI-7442 SPMI-7442 8/30/2005 8/30/2005 8130/2005 8/30/2005 8/30/2005 9/7/2005 9/7/2005 9/22/2005 9/26/2005 10/24/2005 11/4/2005 11/4/2005 11/7/2005 11/7/2005 11/7/2005 11/10/2005 12/1/2005 12/1/2005 12/30/2005 12/30/2005 12/31/2005 12/31/2005 Cs-1 34 Cs-1 37 Sr-89 Sr-90 H-3 Gr. Alpha Gr. Beta C-14 Ni-63 Tc-99 Cs-1 34 Cs-1 37 Cs-1 34 Cs-1 37 Gr. Beta H-3 Gr. Alpha Gr. Beta Cs-1 34 Cs-137 Cs-1 34 Cs-137 47.35 +/- 5.19 62.91 +/- 9.08 11.04 +/- 0.98 65.89 +/- 2.79 77518.20 +/- 753.80 24.61 +/- 0.48 58.35 +/- 0.49 2387.40 +/- 11.00 20.64 +/- 1.23 547.99 +/- 6.69 941.30 +/- 44.10 2570.40 +/- 105.30 41.24 +/- 1.91 114.03 +/- 5.01 1.58 +/- 0.02 77126.00 +/- 747.00 25.16 +/- 0.45 74.58 +/- 0.81

.42.67 +/- 4.22 61.19 +/- 7.20

.40.41 +/- 5.66 60.05 +/- 7.80 47.02 60.37 9.60 65.90 77602.52 20.08 65.73 2370.80 16.70 539.22 886.00 2400.00 44.03 120.24 1.42 76749.00 20.08 65.73 42.03 59.91 42.03 59.91 37.02 - 57.02 50.37 - 70.37 0.00 -19.60 52.72 - 79.08 62082.02 - 93123.02 10.04 - 30.12 55.73 - 75.73 1422.48 - 3319.12 10.02 - 23.38 377.45 - 700.99 797.40 - 974.60 2160.00 - 2640.00 34.03 - 54.03 108.22 - 132.26 1.14 - 11.42 61399.20 - 92098.80 10.04 - 30.12 55.73 - 75.73

.32.03 - 52.03 49.91 - 69.91 32.03 - 52.03 49.91 - 69.91 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass o Liquid sample results are reported in pCl/Liter, air filters( pCI/filter), charcoal (pCi/m3), and solid samples (pCi/g).

b Laboratory codes as follows: W (water), Ml (milk), AP (air filter), SO (soil), VE (vegetation),

CH (charcoal canister), F (fish).

c Results are based on single determinations.

d Control limits are based on Attachment A, Page A2 of this report.

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysis Laboratory results (4.66a)

Acceptance Type LLD Activityb Criteria (4.66 a)

W-11105 W-11105 SPW-765 SPAP-766 STW-2888 W-30105 W-30105 SPW-1837 SPW-1837 SPW-1837 SPW-1 837 SPMI-1839 SPMI-1 839 SPMI-1839 SPCH-1934 SPW-2097 SPW-2923 SPW-2923 SPW-2896 w-60105 w-60105 SPF-3090 SPF-3090 water water water Air Filter water water water water water water water Milk Milk Milk Charcoal water water water water water water Fish Fish 1/11/2005 1/11/2005 2/18/2005 2/18/2005 2/28/2005 3/1/2005 3/1/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/18/2005 4/26/2005 5/31/2005 5/31/2005 6/:1/2005 6/1/2005 6/1/2005 6/7/2005 6/7/2005 Gr. Alpha Gr. Beta H-3 Gr. Beta Tc-99 Gr. Alpha Gr. Beta Cs-1 34 Cs-1 37 1-131 1-131(G) 1-131 Sr-89 Sr-90 1-131(G)

Fe-55 Cs-134 Cs-137 H-3 Gr. Alpha Gr. Beta Cs-1 34 Cs-1 37 0.055 0.15 165.8 0.72 1.32 0.067 0.18 4.66 5.38 0.30 6.56 0.26 0.54 0.53 2.34 859.0 3.29 3.87 138.30 0.061 0.16 15.69 11.71 0.00 + 0.038

-0.016 +/-0.10 7.4 +/- 82.5 0.29 +/- 0.48 0.45 +/- 0.81

-0.007 +/- 0.043

-0.04 +/- 0.11

-0.13 +/-0.16

-0.083 +/- 0.14

-0.069 +/- 0.56 0.88 +/- 0.34 96.1 +/- 528.4 48.1 +/- 85.9 0.002 +/- 0.043 0.056 +/- 0.11 1

3.2 200 3.2 10 1

3.2 10 10 0.5 20 0.5 5

1 9.6 1000 10 10 200 1

3.2 100 100 SPW-SPW-4774 SPW.4776 SPMI-4835 SPMI-4835 SPMI-4835 SPMI-4835 SPMI-4835 SPMI-4835 SPW-4837 SPW-4837 SPW-4837 SPW-4837 SPW-4837 SPW-5015 SPW-5238 water water water Milk Milk Milk Milk Milk Milk water water water water water water water 7/1/2005 8/24/2005 8/24/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 9/22/2005 Ni-63 C-14 Fe-55 Co-60 Cs-1 34 Cs-1 37 1-131 (G)

Sr-89 Sr-90 Co-60 Cs-1 34 Cs-1 37 Sr-89 Sr-90 H-3 C-14 1.60 12.18 833 4.42 4.18 6.25 5.37 0.66 0.66 2.48 3.85 3.00 0.63 0.63 142.8 17.10 0.79 +/- 0.99 2.84 +/- 6.45 275 +/- 525

-0.23 +/- 0.65 1.02 +/- 0.41 0.25 +/- 0.53

-0.035 +/- 0.29 168 +/-93 3.02 +/- 9.04 20 200 1000 10 10 10 20 5

1 10 10 10 5

200 200 A4-1

TABLE A-4. In-House "Blank' Samples Concentration (pCVL)a Lab Code Sample Date Analysis Laboratory results (4.66a)

Acceptance Type LLD Activityb Criteria (4.66 a)

W-90705 water 9/7/2005 Gr. Alpha 0.056 0.034 +/- 0.04 1

W-90705 water 9/7/2005 Gr. Beta 0.16 0.082 +/- 0.11 3.2 SPW-5238 water 9/22/2005 C-14 17.10 3.02 +/- 9.04 200 SPW-5509 water 9/26/2005 Ni-63 1.25 1.23 +/- 0.79 20 SPW-6020 water 10/24/2005 Tc-99 4.81

-1.75 +/- 2.90 10 SPF-6294 Fish 11/4/2005 Cs-134 18.60 100 SPF-6294 Fish 11/4/2005 Cs-137 12.99 100 SPAP-6310 Air Filter 11/7/2005 Cs-134 3.23 100 SPAP-6310 Air Filter 11/7/2005 Cs-1 37 3.86 100 SPAP-6312 Air Filter 11/7/2005 Gr. Beta 1.22

-0.64 +/- 0.64 3.2 W-120105 water 12/1/2005 Gr. Alpha 0.05 0.033 +/- 0.04 1

W-120105 water 12/1/2005 Gr. Beta 0.15

-0.043 +/- 0.11 3.2 SPMI-7419 Milk 12/22/2005 Co-60 7.24 10 SPMI-7419 Milk 12/22/2005 Cs-137 5.61 10 SPMI-7419 Milk 12/22/2005 1-131(G) 10.96 20 SPW-7421 water 12/22/2005 Co-60 2.43 10 SPW-7421 water 12/22/2005 Cs-137 3.12 10 SPW-7441 water 12/30/2005 Cs-134 4.25 10

  • SPW-7441 -

water 12/30/2005 Cs-137 1 63

  • 10 SPMI-7443 Milk 12/30/2005 Cs-134 4.74 10 SPMI-7443 Milk 12/30/2005 Cs-137 8.53 10 a Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/g).

b Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported c 1-131(G); iodine-131 as analyzed by gamma spectroscopy.

d Low levels of Sr-90 are still detected in the environment. A concentration of (1-5 pCUL) in milk is not unusual.

A4-2

TABLE A-5. In-House "Duplicate' Samples Concentration (pCi/L)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SW-62, 63 SW-62, 63 CF-95, 96 CF-95, 96 AP-791, 792 WW-353, 354 SO-383, 384 LW-431, 432 MI-486, 487 SW-511, 512 TD-628, 629 DW-538, 539 MI-564, 565 DW-50134, 5 SWU-893, 894 SW-925, 926 SW-950, 951 SW-950, 951 SW-973, 974 DW-50248, 9 DW-1264,1265 AP-1955,1956 AP-1890, 1891 AP-2025, 2026 MI-1346, 1347 AP-2048, 2049 AP-2081, 2082 1/3/2005 1/3/2005 1/3/2005 1/3/2005 1/14/2005 1/19/2005 1/19/2005 1/27/2005 2/1/2005 2/1/2005 2/1/2005 2/3/2005 2/8/2005 2/11/2005 2/22/2005 2/25/2005 3/1/2005 3/1/2005 3/1/2005 3/16/2005 3/1912005 3/28/2005 3/29/2005 3/29/2005 3/30/2005 3/30/2005 3/30/2005 Gr. Beta K-40 Gr. Beta K-40 Be-7 Gr. Beta H-3 Gr. Beta K-40 1-131 H-3 Gr. Beta K-40 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Gr. Beta 1-131 Gr. Alpha 1-131 Be-7 Be-7 Be-7 K-40 Be-7 Be-7 Gr. Beta Gr. Beta Gr. Beta Gr. Beta K-40 K-40 Gr. Beta 1-131 Cs-1 37 Gr. Alpha Gr. Beta K-40 Sr-90 K-40 K-40 Gr. Alpha 3.01 +/- 0.57 2.00 i 0.20 6.26 +/- 0.23 5.68 +/- 0.59 0.057 +/- 0.017 8.37 +/- 1.21 453.50 +/- 107.20 2.45 +/- 0.54 1319.40 +/- 163.60 0.37 +/- 0.22 489663 +/- 1918 3.93 +/- 1.18 1316.20 +/- 171.10 18.41 +/- 0.98 4.00 +/- 0.96 5.97 +/- 1.51 0.92 +/- 0.27 2.06 +/- 0.40 1.08 +/- 0.19 5.27 +/- 1.06 0.54 +/- 0:21 0.071 +/- 0.009 0.060 +/- 0.013 0.063 +/- 0.012 1252.80 +/- 120.50 0.075 +/- 0.018 0.073 +/- 0.016 2.83 +/- 1.16 11.44 +/- 1.17 7.04 +/- 1.71 2.50 +/- 0.63 3.09 +/- 0.60 1291.50 +/- 177.90 3.69 +/- 0.74 0.58 +/- 0.27 0.11 +/- 0.05 7.55 +/- 2.88 28.74 +/- 2.57 21.51 +/-1.22 32.90 +/- 9.90 1028.10 +/- 99.36 3.08 +/- 0.46 0.06 +/- 0.03 2.39 +/- 0.58 2.10 +/- 0.20 6.28 +/- 0.23 5.37 +/- 0.48 0.07 +/- 0.04 10.28 +/- 1.34 417.90 +/- 106.00 2.20 +/- 0.54 1177.20 +/- 179.70 0.44 +/- 0.23 491225 +/- 1915 3.62 +/- 1.10 1292.60 +/- 154.40 16.76 +/- 0.98 4.20 +/- 0.72 6.14 +/- 1.55 1.21 +/- 0.27 2.29 +/- 0.44 0.92 +/- 0.18 4.17 +/- 0.90 0.73 +/- 0.20 0.071 +/- 0.009 0.069 +/- 0.013 0.071 +/- 0.011 1334.10 +/- 106.60 0.071 +/- 0.015 0.061 +/- 0.018 3.46 +/- 1.23 11.14 +/- 1.62 9.96 +/- 1.65 3.23 +/- 0.67 3.33 +/- 0.40 1323.70 +/- 108.80 3.54 +/- 0.66 0.49 +/- 0.27 0.11 +/- 0.04 12.41 +/- 3.38 28.17 +/- 2.52 21.42 +/- 1.24 29.60 +/- 13.90 1206.70 +/- 118.50 3.04 +/- 0.51 0.07 +/- 0.04 2.70 +/- 0.41 2.05 +/- 0.14 6.27 +/- 0.16 5.53 +/- 0.38 0.06 +/- 0.02 9.32 +/- 0.90 435.70 +/- 75.38 2.33 +/- 0.38 1248.30 +/- 121.51 0.40 +/- 0.16 490444 +/- 1355 3.78 +/- 0.81 1304.40 +/- 115.23 17.59 +/- 0.69 4.10 +/- 0:60 6.06 +/- 1.08 1.07 +/- 0.19 2.18 +/- 0.30 1.00 +/- 0.13 4.72 +/- 0.70 0.63 +/- 0.15 0.071 +/- 0.006 0.065 +/- 0.009 0.067 +/- 0.008 1293.45 +/- 80.44 0.073 +/- 0.012 0.067 +/- 0.012 3.14 +/- 0.85 11.29 +/- 1.00 8.50 +/- 1.19 2.86 +/- 0.46 3.21 +/- 0.36 1307.60 +/- 104.27 3.62 +/- 0.50 0.53 +/- 0.19 0.11 +/-0.03 9.98 +/- 2.22 28.46 +/- 1.80 21.47 i 0.87 31.25 +/- 8.53 1117.40 +/- 77.32 3.06 +/- 0.34 0.07 +/- 0.03 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass SWU-1521, 1522 3/31/2005 WW-1738, 1739 SW-1857,1858 LW-1911,1912 F-1976, 1977 MI-2111, 2112 SWU-2158, 2159 DW-2349, 2350 SO-2305, 2306 SO-2305, 2306 SO-2305, 2306 SO-2305, 2306 SO-2305, 2306 MI-2260, 2261 F-2630, 2631 VE-2502, 2503 4/5/2005 4/13/2005 4/14/2005 4/18/2005 4/26/2005 4/26/2005 4/29/2005 5/2/2005 5/2/2005 5/2/2005 5/2/2005 5/2/2005 5/3/2005 5/5/2005 5/10/2005 A5-1

TABLE A-5. In-House Duplicate" Samples

)

Concentration (pC!/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-2502, 2503 VE-2502, 2503 G-2546, 2547 G-2546, 2547 SS-2787, 2788 SS-2787, 2788 SO-3056, 3057 SO-3056, 3057 SS-3175, 3176 S0-2865, 2866 S0-2865, 2866 SO-2865, 2866 DW-2935, 2936 SWU-3103, 3104 G-2958, 2959 G-2958, 2959 b G-2958, 2959 BS-4089, 4090 BS-4089, 4090 DW-50527, 8 VE-3278; 3279 MI-3299, 3300 BS-3348, 3349 BS-3348, 3349 BS-3348, 3349 DW-3486, 3487 SWT-3631, 3632 W-3507, 3508 VE-3555, 3556 VE-3555, 3556 AP-3781, 3782 LW-3610, 3611 SW-3760, 3761 E-3654, 3655 E-3654, 3655 MI-3676, 3677 DW-3739, 3740 W-3808, 3809 DW-3938, 3939 VE-3896, 3897 MI-3963, 3964 DW-4068, 4069 5/1012005 5/10/2005 5/11/2005 5/11/2005 5/18/2005 5/18/2005 5/19/2005 5/19/2005 5/23/2005 5/25/2005 5/25/2005 5/25/2005 5/27/2005 6/1/2005 6/1/2005 6/1/2005 6/1/2005 6/3/2005 6/3/2005 6/8/2005 6/13/2005 6/15/2005 6/17/2005 6/17/2005 6/17/2005 6/28/2005 6/28/2005 6129/2005 6/29/2005 6/29/2005 6/29/2005 6/30/2005 6/30/2005 7/5/2005 7/5/2005 7/5/2005 7/5/2005 7/6/2005 7/8/2005 7/12/2005 7/13/2005 7/15/2005 Gr. Beta K-40 Be-7 K-40 Cs-I 37 K-40 Cs-137 K-40 K-40 Cs-1 37 Gr. Beta K-40 1-131 Gr. Beta Be-7 Gr. Beta K-40 Co-60 Cs-1 37 Gr. Alpha K-40 K-40 Co-60 Cs-137 K-40 Gr. Beta Gr. Beta H-3 Gr. Beta K-40 Be-7 Gr. Beta Gr. Beta Gr. Beta K-40 K-40 1-131 H-3 1-131 K-40 K-40 1-131 3.81 +/-0.10 3.79 +/- 0.40 0.81 +/- 0.39 9.43 +/-1.00 0.13 +/- 0.04 12.44 +/- 0.76 0.18 +/- 0.04 20.06 +/- 1.10 6.06 +/- 0.44 0.18 +/- 0.04 32.95 +/- 2.48 21.93 +/- 0.97 0.51 +/- 0.34 3.29 +/- 0.49 1.06 +/- 0.40 8.06 +/- 0.07 5.93 +/- 0.73 0.11 +/-0.02 0.60 +/- 0.05 11.58 +/- 1.31 6.34 +/- 0.59 1215.40 +/- 110.20 0.20 +/- 0.04 2.59 +/- 0.10 11.57 +/- 0.81 0.97 +/- 0.54 2.12 +/- 0.53 38717 +/- 382 7.53 +/- 0.18 5.70 +/- 0.52 0.09 +/- 0.02 1.37 i 0.35 9.70 +/- 1.63 1.76 i 0.07 1.49 +/- 0.25 1383.90 +/- 116.20 1.93 +/- 0.24 4189.61 +/- 196.68 1.11 +/- 0.30 3.44 +/- 0.62 1438.70 +/- 102.80 0.64 +/- 0.27 3.86 +/- 0.10 4.30 +/- 0.59 1.25 +/- 0.38 7.96 +/- 0.85 0.14 +/- 0.05 13.33 +/- 0.83 0.17 +/- 0.01 21.73 +/- 0.36 5.96 +/- 0.61 0.18 +/- 0.03 33.88 +/- 2.36 22.32 +/- 0.98 0.56 +/- 0.30 3.75 +/- 0.66 1.21 +/- 0.28 7.79 +/- 0.07 6.05 +/- 0.28 0.10 +/- 0.02 0.62 +/- 0.05 13.52 i 1.43 7.29 +/- 0.68 1250.70 +/- 106.70 0.22 +/- 0.04 2.51 +/- 0.07 11.82 +/- 0.76 1.67 +/- 0.58 1.62 +/- 0.56 38017 +/- 535 7.56 +/- 0.18 5.64 +/- 0.53 0.08 +/- 0.02 1.40 +/- 0.36 9.77 +/- 1.61 1.69 +/- 0.07 1.05 +/- 0.21 1428.20 +/- 125.40 2.18 +/- 0.23 4438.33 +/- 201.39 1.26 +/- 0.31 3.60 +/- 0.36 1351.80 +/- 100.80 0.91 +/- 0.28 3.83 +/- 0.07 4.04 +/- 0.36 1.03 +/- 0.27 8.70 +/- 0.66 0.13 +/- 0.03 12.88 +/- 0.56 0.18 +/- 0.02 20.90 +/- 0.58 6.01 +/- 0.38 0.18 +/- 0.02 33.41 +/- 1.71 22.13 +/- 0.69 0.53 +/- 0.23 3.52 +/- 0.41 1.14 +/- 0.24 7.93 +/- 0.05 5.99 +/- 0.39 0.11 +/- 0.02 0.61 +/- 0.04 12.55 +/- 0.97 6.81 +/- 0.45 1233.05 +/- 76.70 0.21 +/- 0.03 2.55 +/- 0.06 11.69 +/- 0.56 1.32 +/- 0.40 1.87 +/- 0.39 38367 +/- 329 7.55 +/- 0,13 5.67 +/- 0.37 0.09 +/- 0.01 1.39 +/- 0.25 9.73 +/- 1.15 1.72 +/- 0.05 1.27 +/- 0.16 1406.05 +/- 85.48 2.05 +/- 0.17 4313.97 +/- 140.75 1.18 +/- 0.22 3.52 +/- 0.36 1395.25 +/- 71.99 0.78 +/- 0.20 Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-4290, 4291 7/26/2005 VE-4290, 4291 7/26/2005 SWU-4311, 4312 7/26/2005 SWU-4311, 4312 7/26/2005 G-4383, 4384 8/1/2005 G-4383, 4384 8/1/2005 G-4383, 4384 8/1/2005 MI-4425, 4426 8/1/2005 TD-4446,4447 8/1/2005 SL-4473, 4474 8/4/2005 SL-4473, 4474 8/4/2005 VE-4532,4533 8/5/2005 VE-4618, 4619 8/9/2005 VE-4618, 4619 8/9/2005 VE-4618,4619 8/9/2005 F-4639, 4640 8/11/2005 F-4639, 4640 8/11/2005 F-4639, 4640 8/11/2005 DW-4730,4731 8/12/2005 MI-4855, 4856 8/28/2005 MI-4855, 4856 8/28/2005 MI-4945, 4946 8/31/2005 MI-4945, 4946 8/31/2005 TD-4921, 4922 9/1/2005 VE-4900, 4901 9/2/2005 VE-4900, 4901 9/2/2005 DW-50769, 50770 9/2/2005 VE-4990 4991 9/6/2005 MI-501 1, 5012 9/8/2005 VE-5119, 5120 9/12/2005 VE-5119, 5120 9/12/2005 VE-5119, 5120 9/12/2005 LW-5361, 5362 9/12/2005 SW-5098, 5099 9/13/2005 LW-5178, 5179 9/14/2005 DW-5239, 5240 9/16/2005 CF-5432, 5433 9/19/2005 CF-5432, 5433 9/19/2005 MI-5292, 5293 9/21/2005 BS-5340, 5341 9/23/2005 BS-5340, 5341 9/23/2005 Gr. Alpha Gr. Beta Gr. Beta H-3 Be-7 Gr. Beta K-40 K-40 H-3 Gr. Beta K-40 Gr. Beta Gr. Alpha Gr. Beta K-40 Cs-1 37 Gr. Beta K-40 1-131 K-40 Sr-90 K-40 Sr-90 H-3 Gr. Beta K-40 Gr. Alpha K-40 K-40 Gr. Alpha Gr. Beta K-40 Gr. Beta 1-131 Gr. Beta 1-131 Be-7 K-40 K-40 Be-7 Cs-1 37 0.11 i0.04 4.55 i 0.13 2.62 +/- 0.64 192.30 +/-92.90 2.06 +/-0.49 8.76 +/- 0.22 6.74 +/-0.64 1358.10 +/- 169.20 563.00 +/-252.00 5.44 +/- 0.48 2.91 +/- 0.83 31.20 +/- 1.20 0.09 +/- 0.05 4.60 +/- 0.13 4.19 +/-0.46 0.05 +/- 0.02 3.33 +/- 0.11 2.62 +/-0.57 0.82 +/- 0.23 1341.50 +/- 107.70 0.77 +/- 0.37 1388.90 +/- 158.90 0.67 +/-0.34 5737.00 +/- 266.00 3.40 +/- 0.06 2.15 +/- 0.27 6.17 +/-1.42 18.81 +/- 1.12 1584.00 +/- 194.00 0.10 0 0.06 6.05 +/- 0.18 4.61 +/-0.46 1.09 +/- 0.33 0.44 +/- 0.22 2.92 +/- 0.56 0.45 +/- 0.27 0.91 +/- 0.40 1.43 +/- 0.34 1228.80 +/- 78.13 1286.10 +/- 550.80 726.97 +/- 76.24 0.05 +/- 0.03 4.69 +/- 0.14 1.67 +/- 0.37 304.60 +/- 97.40 1.76 +/- 0.29 8.40 +/- 0.20 6.88 +/- 0.92 1267.90 +/- 164.40 529.00 +/- 251.00 4.57 +/- 0.42 2.74 +/- 0.54 31.70 +/- 1.20 0.09 +/- 0.04 4.54 +/- 0.12 4.34 +/- 0.47 0.05 +/- 0.02 3.37 +/- 0.10 2.58 +/- 0.59 0.83 +/- 0.25 1340.00 +/- 114.70 0.87 +/- 0.37 1307.50 +/- 165.20 0.82 +/- 0.36 5860.00 +/- 269.00 3.51 +/- 0.06 2.27 +/- 0.24 6.08 +/- 1.46 19.52 +/- 0.86 1707.60 +/- 173.00 0.09 +/- 0.05 5.92 +/- 0.17 4.74 +/- 0.69 1.18 +/- 0.34 0.31 +/- 0.20 2.95 +/- 0.59 0.55 +/- 0.29 0.64 +/- 0.30 1.38 +/- 0.43 1297.00 +/- 81.03 1222.90 +/- 394.40 677.49 +/- 70.03 0.08 +/- 0.03 4.62 +/- 0.09 2.15 +/- 0.37 248.45 +/- 67.30 1.91 +/- 0.28 8.58 +/- 0.15 6.81 +/- 0.56 1313.00 +/- 117.96 546.00 +/- 177.84 5.00 +/- 0.32 2.82 +/- 0.49 31.45 +/- 0.85 0.09 +/- 0.03 4.57 +/- 0.09 4.27 +/- 0.33 0.05 +/- 0.02 3.35 +/- 0.07 2.60 +/- 0.41 0.83 +/- 0.17 1340.75 +/- 78.67 0.82 +/- 0.26 1348.20 +/- 114.61 0.75 +/- 0.25 5798.50 +/- 189.15 3.45 +/- 0.04 2.21 +/- 0.18 6.13 +/- 1.02 19.11 +/- 0.71 1645.80 +/- 129.97 0.10 +/- 0.04 5.98 +/- 0.12 4.68 +/- 0.41 1.13 +/- 0.24 0.38 +/- 0.15 2.93 +/- 0.41 0.50 +/- 0.20 0.78 +/- 0.25 1.41 +/- 0.27 1262.90 +/- 56.28 1254.50 +/- 338.72 702.23 +/- 51.76 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance BS-5340, 5341 DW-5382, 5383 MI-5405, 5406 AP-5769, 5770 AP-5983, 5984 AP-5878, 5879 G-5526, 5527 G-5526, 5527 G-5526, 5527 VE-5721, 5722 VE-5721, 5722 VE-5721, 5722 CF-5695, 5696 CF-5695, 5696 LW-6129, 6130 LW-6129,6130 DW-50844, 5 LW-5748, 5749 c AP-6485, 6486 SWU-6156, 6157 VE-6186, 6187 LW-6203, 6204 S0-6270, 6271 S0-6270, 6271 S0-6270, 6271 TD-6320, 6321 SO-6605, 6606 CF-6509, 6510 SW-6638,6639 SO-6887, 6888 S0-6887, 6888 S0-6887, 6888 SWT-6721, 6722 VE-6775, 6776 LW-6743, 6744 DW-51023,4 SWT-7282, 7283 9/23/2005 9/23/2005 9/27/2005 9/27/2005 9/27/2005 9/29/2005 10/3/2005 10/3/2005 10/3/2005 10/10/2005 10/10/2005 10/10/2005 10/11/2005 10/11/2005 10/11/2005 10/11/2005 10/11/2005 10/12/2005 10/20/2005 10/25/2005 10/26/2005 10/27/2005 10/28/2005 10/28/2005 10/28/2005 11/1/2005 11/11/2005 11/14/2005 11/22/2005 11/22/2005 11/22/2005 11/22/2005 11/29/2005 11/29/2005 11/30/2005 12/2/2005 12/27/2005 K-40 1-131 K-40 Be-7 Be-7 Be-7 Be-7 Gr. Beta K-40 Gr. Alpha Gr. Beta K-40 Be-7 K-40 Gr. Beta H-3 Gr. Beta Gr. Beta Be-7 Gr. Beta K-40 Gr. Beta Cs-1 37 Gr. Beta K-40 H-3 Gr. Beta K-40 1-131 Gr. Alpha Gr. Beta K-40 Gr. Beta Gr. Beta Gr. Beta Gr. Alpha Gr. Beta 12404 +/- 1154 0.79 +/- 0.31 1324.80 +/- 112.20 0.08 +/- 0.01 0.08 +/- 0.01 0.06 +/- 0.01 4.03 +/- 0.62 8.10 +/- 0.30 4.93 +/- 0.67 0.07 +/- 0.05 5.09 +/- 0.15 4.27 +/- 0.43 2.70 +/- 0.37 11.79 +/- 0.86 1.34 +/- 0.25 304.35 +/- 95.31 5.30 +/- 1.50 1.09 +/- 0.25 0.10 +/- 0.03 4.69 +/- 1.34 2.90 +/- 0.49 2.92 +/- 0.62 0.33 +/- 0.03 26.85 +/- 2.78 13.67 +/- 0.74 444202 +/- 1770 18.22 +/- 2.23 0.85 +/- 0.14 0.95 +/- 0.35 6.80 +/- 2.92 19.27 +/- 2.16 14.29 +/- 1.11 0.98 +/- 0.31 12.75 +/- 0.28 3.19 +/- 0.47 0.55 +/- 1.40 1.62 +/- 0.37 13033 +/- 983 0.53 +/- 0.31 1366.80 +/- 99.44 0.09 +/- 0.02 0.08 +/- 0.01 0.07 +/- 0.01 4.07 +/- 0.80 8.80 i 0.40 6.00 +/- 0.72 0.08 +/- 0.06 5.00 +/- 0.16 4.20 +/- 0.34 2.80 +/- 0.34 13:11 i+/- 0.68 1.85 +/- 0.29 369.23 +/- 97.88 4.20 +/- 1.40 1.89 +/- 0.28 0.09 +/- 0.03 4.18 +/- 1.34 2.83 +/- 0.51 3.09 +/- 0.66 0.34 +/- 0.04 22.25 +/- 2.41 14.02 +/- 0.76 446633 +/- 1775 18.47 +/- 2.22 0.99 +/- 0.22 0.67 +/- 0.31 10.27 +/- 3.26 18.43 +/- 2.21 13.78 +/- 0.78 0.87 +/- 0.31 13.16 +/- 0.21 2.50 +/- 0.44 2.21 +/- 1.31 1.85 +/- 0.38 12719 +/- 758 0.66 +/- 0.22 1345.80 +/- 74.96 0.08 +/- 0.01 0.08 +/- 0.01 0.07 +/- 0.01 4.05 +/- 0.51 8.41 +/- 0.24 5.47 +/- 0.49 0.08 +/- 0.04 5.05 +/- 0.11 4.23 +/- 0.27 2.75 +/- 0.25 12.45 +/- 0.55 1.59 +/- 0.19 336.79 +/- 68.31 4.75 +/- 1.03 1.49 +/- 0.19 0.09 +/- 0.02 4.44 +/- 0.95 2.87 +/- 0.35 3.01 +/-0.45 0.33 +/- 0.03 24.55 +/- 1.84 13.85 +/- 0.53 445418 +/- 1253 18.35 +/- 1.57 0.92 i0.13 0.81 +/-0.23 8.53 i 2.19 18.85 +/- 1.54 14.03 +/- 0.68 0.93 +/- 0.22 12.96 +/- 0.18 2.85 +/- 0.32 1.38 +/- 0.96 1.74 +/- 0.27 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house.

analyses with activities that measure below the LLD.

Results are not listed for those a Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCi/g).

b 600 minute count time or longer, resulting in lower error.

c Recount of W-5748, 2.38 +/- 0.85 pCi/L Averaged result; 2.14 +/- 0.45 pCi/L A5-4

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

I Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STW-1045 STW-1045 01/01/05 Gr. Alpha 01101/05 Gr. Beta 0.45 +/- 0.10 1.90 i 0.10 0.53 1.67 0.00 - 1.05 0.84 - 2.51 Pass Pass STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01S01/05 01/01/05 Am-241 Co-57 Co-60 Cs-134 Cs-137 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-23314 U-238 Zn-65 1.62 +/- 0.12 239.40 +/- 1.20 248.70 +/- 1.00 115.50 +/- 1.80 328.50 +/- 1.70 64.90 +/- 7.00 304.00 +/- 9.70 334.80 +/- 1.90 7.10 +/- 1.60 0.01 +/- 0.02 2.50 +/- 0.14 0.70 +/- 0.80 43.20 +/- 1.40 3.31 +/- 0.20 3.38 +/- 0.20 538.40 +/- 3.80 1.72 227.00 251.00 127.00 332.00 75.90 280.00 331.00 9.00 0.02 2.40 0.00 42.90 3.24

. 3.33 496.00 1.20 - 2.24 158.90 - 295.10 175.70 - 326.30 88.90 - 165.10 232.40 - 431.60 53.13 - 98.67 196.00 - 364.00 231.70 - 430.30 0.00 - 20.00 0.00 - 1.00 1.68 - 3.12 0.00 - 5.00 30.03 - 55.77 2.27 - 4.21 2.33 - 4.33 347.20 - 644.80 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STVE-1047 01/01/05 Co-57 STVE-1047 01/01/05 Co-60 STVE-1047 01/01/05 Cs-134 STVE-1047 01/01/05 Cs-137 STVE-1047 01/01/05 Mn-54 STVE-1047

'01/01/05 Zn-65 10.60 +/- 0.20 3.00 +/- 0.20 4.80 +/- 0.40 4.10 +/- 0.30 5.10 +/- 0.30 6.20 i 0.50

  • 9.88-3.15
  • 5.00 4.11 5.18 6.29 6.92 - 12.84 2.21 - 4.10 3.50 - 6.50 2.88 - 5.34 3.63 - 6.73 4.40 - 8.18 Pass Pass Pass Pass Pass Pass STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1 048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 96.60 +/- 10.00 264.00 +/- 2.00 226.50 +/- 2.20 760.60 +/- 3.70 336.20 +/- 3.60 663.70 +/- 18.00 541.30 +/- 3.90 924.30 +/- 17.20 0.60 +/- 0.80 78.00 +/- 4.80 514.60 +/- 18.70 47.90 +/- 4.00 226.30 +/- 8.60 851.30 +/- 7.30 0.11 +/- 0.03 0.38 +/- 0.05 109.00 242.00 212.00 759.00 315.00 604.00 485.00 1220.00 0.48 89.50 640.00 62.50 249.00 810.00 0.23 0.30 76.30 - 141.70 169.40 -314.60 148.40 - 275.60 531.30 - 986.70 220.50 - 409.50 422.80 - 785.20 339.50 - 630.50 854.00 - 1586.00 0.00 - 1.00 62.65 - 116.35 448.00 - 832.00 43.75 - 81.25 174.30 - 323.70 567.00 - 1053.00 0.00 - 0.46 0.15 -0.45 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STAP-1050 01/01/05 Gr. Alpha STAP-1050 01/01/05 Gr. Beta A6-1

TABLE A-6. Department of Energy's MiXed Analyte Performance Evaluation Program (MAPEP)a.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STAP-1049 STAP-1049 STAP-1049 STAP-1049 STAP-1049 STAP-1 049 STAP-1049 STAP-1049 STAP-1049e STAP-1049 STAP-1049 STAP-1 049 01/01/05 01/01/05 01/01/05 01/01/05 01101/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 Am-241 Co-57 Co-60 Cs-134 Cs-I 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 0.10 +/-0.04 4.76 +/- 0.64 2.84 +/- 0.22 3.54 +/- 0.37 2.20 +/- 0.27 3.15 +/- 0.21 0.16 +/- 0.04 0.17 +/- 0.02 2.24 +/- 0.34 0.34 +/- 0.02 0.35 +/- 0.02 3.12 +/- 0.15 0.10 4.92 3.03 3.51 2.26 3.33 0.20 0.17 1.35 0.34 0.35 3.14 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1062 STW-1062 STSO-1063' STSO-1063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1063 STSO-1 063 STSO-1063 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05

.07/01/05 07/01/05

.07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07101/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-I 37 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 Gr. Alpha Gr. Beta Am-241 Co-57 Co-60 Cs-i 34 Cs-I 37 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 2.21 +/-0.13 293.20 +/- 7.30 275.70 +/- 1.30 171.80 +/-4.00 342.10 +/- 2.20 167.80 +/- 9.30 514.20 +/- 12.60 437.00 +/- 2.50 105.10

  • 3.60 1.64 +/- 0.12 2.32 +/- 0.13 9.20 +/- 1.30 72.30 +/- 2.30 4.11 +/- 0.18 4.14 +/- 0.18 364.60 +/- 4.90 0.57 +/- 0.05 1.36 +/- 0.05 48.40 +/- 3.90 608.30 +/- 2.80 322.70 +/- 2.40 632.10 +/- 5.20 512.40 +/- 4.20 720.50 +/- 19.00 516.80 +/- 5.10 366.50 +/- 13.30 68.80 +/- 15.00 0.00 +/- 0.00 602.90 +/- 17.20 61.50 +/- 1.00 164.50 +/- 16.70 874.70 +/- 8.40 2.23 272.00 261.00 167.00 333.00 196.00 527.00 418.00 100.00 1.91 2.75 8.98 66.50 4.10 4.26 330.00 0.79 1.35 81.10 524.00 287.00 568.00 439.00 604.00 439.00 445.00 60.80 0.00 757.00 52.50 168.00 823.00 0.07 - 0.13 3.44 - 6.40 2.12 - 3.94 2.46 - 4.56 1.58 - 2.94 2.33 - 4.33 0.14 - 0.25 0.14 - 0.25 0.95 - 1.76 0.24 - 0.44 0.25 - 0.46 2.20 - 4.08 1.56 - 2.90 190.40 - 353.60 182.70 - 339.30 116.90 - 217.10 233.10 - 432.90 137.20 - 254.80 368.90 - 685.10 292.60 - 543.40 70.00 - 130.00 1.34 - 2.48 1.93 - 3.58 6.29 - 11.67 46.55 - 86.45 2.87 - 5.33 2.98 - 5.54 231.00 - 429.00 0.21 - 1.38 0.85 - 1.92 56.77 - 105.43 366.80 - 681.20 200.90 -373.10 397.60 - 738.40 307.30 - 570.70 422.80 - 785.20 307.30 - 570.70 311.50 - 578.50 42.56 -79.04 0.00 - 0.00 529.90 - 984.10 36.75 - 68.25 117.60 - 218.40 576.10 - 1070.00 Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A6-2

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEPr.

Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STVE-1064 07/01/05 Am-241 0.18 i 0.03 0.23 0.16 - 0.30 Pass STVE-1064 07/01/05 Co-57 15.90 +/- 0.20 13.30 9.31 - 17.29 Pass STVE-1 064 07/01/05 Co-60 4.80 i 0.10 4.43 3.10 - 5.76 Pass STVE-1064 07/01/05 Cs-1 34 4.60 i 0.20 4.09 2.86 - 5.32 Pass STVE-1064 07/01/05 Cs-1 37 5.90 i 0.30 5.43 3.80 -7.06 Pass STVE-1 064 07/01/05 Mn-54 7.20 i 0.20 6.57 4.60 - 8.54 Pass STVE-1064 07/01/05 Pu-238 0.04 i 0.02 0.00 0.00 - 1.00 Pass STVE-1064 07/01/05 Pu-239/40 0.13 i 0.02 0.16 0.11 - 0.21 Pass STVE-1 064 07/01/05 Sr-90 2.80 i 0.30 2.42 1.69 - 3.15 Pass STVE-1 064 07/01/05 U-233/4 0.28 i 0.03 0.33 0.23 - 0.43 Pass STVE-1064 07/01/05 U-238 0.33 i 0.04 0.35 0.24 -0.45 Pass STVE-1 064 07/01/05 Zn-65 11.00 i 0.50 10.20 7.14 - 13.26 Pass STAP-1065 07/01/05 Gr. Alpha 0.30 i 0.04 0.48 0.00 - 0.80 Pass STAP-1 065 07/01/05 Gr. Beta 0.97 i 0.06 0.83 0.55 - 1.22 Pass STAP-1066 07/01/05 Am-241 0.14 i 0.03 0.16 0.11 -0.21 Pass STAP-1066 07/01/05 Co-57 5.81 i 0.17 6.20 4.34 -8.06 Pass STAP-1 066 07/01/05 Co-60 2.79 +/- 0.14 2.85 2.00 - 3.71 Pass STAP-1066 07/01/05 Cs-134 3.67 +/- 0.12 3.85 2.70 - 5.01 Pass STAP-1066 07/01/05 Cs-1 37 2.93 +/- 0.23 3.23 2.26 -4.20 Pass STAP-1066 07/01/05 Mn-54 4.11 +/- 0.26 4.37 3.06 -5.68 Pass STAP-1066 07/01/05 Pu-238 0.11 +/- 0.02 0.10 0.07 -0.13 Pass STAP-1066 07/01/05 Pu-239/40 0.10 +/- 0.01 0.09 0.06 - 0.12 Pass STAP-1066 07/01/05 Sr-90 2.25 +/- 0.29 2.25 1.58 - 2.93 Pass STAP-1 066 07/01/05 U-233/4 0.28 +/- 0.02 0.27 0.19 -0.35 Pass STAP-1066 07/01/05 U-238 0.28 +/- 0.02 0.28 0.20 - 0.37 Pass STAP-1066 07/01/05 Zn-65 4.11 +/- 0.26 4.33 3.06 -5.68 Pass

'Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the Departme It of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation) as requested by the Department of Energy.

c Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

d MAPEP results are presented as the known values and expected laboratory precision (1 sigma, I determination) and control limits as defined by the MAPEP.

I I

The strontium carbonate precipitates were redissolved and processed. The average of the three analyses was 1.34 1 although the recovery was only 30%. The result of a new analysis was 1.56 pCi/L.

' Incorrect sample weight used in calculation. Result of recalculation: 97.0 +/- 7.8 Bq/kg.

A6-3

APPENDIX B DATA REPORTING CONVENTIONS B-1

Data Reportinq Conventions 1.0. All activities, except gross alpha. and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x t s where:

x = value of the measurement; s = 2s counting uncertainty (corresponding to the.95% confidence level).

In cases where the acivity is less than the lower limit of detection L, it is.reported as: AL, where L = the lower limit.of detection based on 4.66s uncertainty 1fora background sample.

3.0. Duplicate analyses 3.1 Individual results: For two analysis results; x1 i 5s and X2 i s2 Reported result:

x +/-s; where x = (1/2) (xi + x2) and s 1/2) JS 3.2.

Individual results:

<L1, <2 X Reoortedresult <L,.whereL =-lower of;L: and L2 3.3.

Individual results:

x +/- s, <L Revorted result:.

..x

  • s if x 2L; o.therwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation s of a set of n numbers xj, x2... xn are defined as follows:

x =n Ex S=

n-4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-2

POINT BEACH NUCLEAR PLANT APPENDIX C Sampling Program and Locations C-1

POINT BEACH NUCLEAR PLANT Locations Collection Type Analysis Sample Type No.

Codes (and Type)a (and Frequency)b (and Frequency)b Airborne Filters 6

E-1-4,8,20 Weekly GB, GS, on QC for each location 1-131 Ambient Gamma Airborne Iodine Ambient Radiation (TLD's)

Lake Water Well Water Vegetation 6

E-1-4, 8, 20 22 E-1-9, 12,14-18, 20, 22-32, 34-36, 38,39 5

E-1,5,6,33 1

E-10 8

E-1-4, 6. 9, 20 Weekly Quarterly Monthly GB, BS, 1-131 on MC H-3, Sr-89-90 on QC Quarterly GB, GS, H-3, Sr-89-90, 1-131 Shoreline Silt Soil Milk Algae 5

8 3

E-1, 5, 6,8,9,12 E-1-4, 6, 8, 9, 20 E-11, 40, 21 3x/year as available 2x / year 2x / year Monthly 3x I year as available GB, GS GB, GS GB, GS GS, 1-131, Sr-89-90 GB, GS 2

E-5, 12 Fish 1

E-13 3x / year GB, GS (in edible portions) as available SPECIAL COLLECTIONS AND ANALYSES Airborne Filters Liquid Subsoil Water 4 per month

  • I per qUarter 1 per month 4 per quarter 4-5 per year Sr-89, Sr-90 Sr-89, Sr-90 (comp.)

GA, Sr-89, Sr-90 GA, GB, H-3, GS Sr-89, Sr-90 Miscellaneous Water Samples

' Locations codes are defined in Table 2. Control Stations are indicated by (C). All other stations are indicators.

D Analysis type is coded as follows: GB = gross beta, GA = gross alpha. GS = gamma spectroscopy, H-3 = tritium, Sr-89 = strontium-89, Sr-90 = strontium-90, 1-131 = iodine-131. Analysis frequency is coded as follows:

MC = monthly composite, QC = quarterly composite.

C-2

POINT BEACH NUCLEAR PLANT

)

APPENDIX D Graphs of Data Trends f

I i

1 i

,i I

f' D-1

POINT BEACH Air Particulates - Gross Beta 0.05 Location E-1, monthly averages 2005-2009 0.04.

0.01 CV, E

0.02 -

0.01 2005 2006 2007 Year 2008 2009 2010 0.05 l Location E-2, monthly averages 2005-2009 0.04 0.03 I -

0.02k 0.01.

0 l

2005 2006 2007 Year 2008 2009 2010 D-2

POINT BEACH Air Particulates - Gross Beta Location E-3, monthly averages 2005-2009 0.05 -

0.04--

0.03 E

i-0 0.02 -

0.01 n I

-A-2005 2006 2007 Year 2008 2009

- 2010 0.05*

0.04 -

0.03-E 0

a 0.02 -

Location E-4, monthly averages 2005-2009

. I...I-..

I 0.01 0 II 2005 2006 2007 Year 2008 2009 2010 D-3

POINT BEACH Air Particulates - Gross Beta

.I Location E-8, monthly averages 2005-2009 0.05 l 0.04 -

0.03 CY) 0.01 -

I 2010 2005 2006 207Year 2008 2009 0.05 Location E-20, monthly averages 2005-2009 0.04 -

0.03 0.02.

0.01........

0 - _

2005 2006 2007 Year 2008 2009 2010 D4