NLS2005029, Request for Use of Delta Protection Single-Use Supplied-Air Suits

From kanterella
(Redirected from ML053470189)
Jump to navigation Jump to search

Request for Use of Delta Protection Single-Use Supplied-Air Suits
ML053470189
Person / Time
Site: Cooper Entergy icon.png
Issue date: 12/08/2005
From: Minahan S
Nebraska Public Power District (NPPD)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NLS2005029
Download: ML053470189 (46)


Text

Nebraska Public Power District Always there when you need us 20.1703(b)

20. 1705 NLS2005029 December 8, 2005 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Subject:

Request for Use of Delta Protection Single-Use Supplied-Air Suits Cooper Nuclear Station, Docket No. 50-298, DPR-46 The purpose of this letter is for the Nebraska Public Power District (NPPD) to request authorization to use single-use supplied-air suits manufactured by Delta Protection and request assignment of a protection factor. NPPD has identified the Delta Protection suits as having benefits from a contamination control, heat stress reduction, and respiratory protection point of view. These suits are not approved by the National Institute for Occupation Safety and Health (NIOSH) for use as a respirator in the United States. Pursuant to 10 CFR 20.1703(b), NPPD must request authorization for use of equipment that has not been tested or certified by NIOSH.

Pursuant to 10 CFR 20.1705, NPPD must obtain authorization from the Nuclear Regulatory Commission (NRC) before using assigned protection factors in excess of those specified in Appendix A of 10 CFR 20. Since these suits are not approved by NIOSH for use as a respirator in the United States, NPPD is requesting authorization for their use as respiratory protection equipment and requesting an assigned protection factor of 2000.

Attachment I provides documentation supporting the request. As described in the attachment, approval of the request would improve worker safety in areas of airborne radioactivity and areas of high potential for facial/skin contamination from hot particles.

NPPD has identified the following as commitments associated with this request.

I. The Mururoa V4 MTH2 single-use suit will be integrated into the NPPD respiratory program using information provided by the manufacturer.

2. New lesson plans will be developed to train workers on Mururoa's features, donning, use and removal, cautions, and use of mouth strip and tear off strips for routine and emergency egress.
3. Radiation Protection personnel will be provided additional training for selection, approval, issue, equipment set-up, operation and maintenance instructions for the Mururoa suit.
4. NPPD will report any defects of these suits in a timely manner to the United States nuclear industry through our Operating Experience process and to the manufacturer.

COOPERNUCLEARSTAT1ON.

'4A P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 www.nppd.com

NLS2005029 Page 2 of 2

5. All instructions for use and emergency features supplied by the manufacturer will be included in our procedures/training.
6. NPPD understands that this is a single use suit and will discard each suit after a single use.

Approval of the suit's use will allow the plant to proceed with procedure changes and complete training necessary for the use of the V4 MTH2 suits for future outages. Therefore NPPD is requesting approval by May 31, 2006.

Should you have any questions or require additional information, please contact Paul Fleming, Licensing Manager, at (402) 825-2774.

Sincerely, Stewart B. Minahan General Manager of Plant Operations

/cb Attachment Enclosures cc:

Regional Administrator w/ attachment and enclosures USNRC - Region IV Senior Project Manager w/ attachment and enclosures USNRC - NRR Project Directorate IV-I Senior Resident Inspector w/ attachment and enclosures USNRC - CNS Nebraska Health and Human Services w/ attachment and enclosures Department of Regulation and Licensure NPG Distribution w/o attachment and enclosures CNS Records w/ attachment and enclosures

I ATTACHMENT 3 LIST OF REGULATORY COMMITMENTSO I

Correspondence Number: NLS2005029 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are not regulatory commitments. Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.

COMMITMENT COMMITTED DATE COMMITMENT NUMBER OR OUTAGE The Mururoa V4 MTH2 single use suit will be integrated into the NPPD respiratory NLS2005029-01 Prior to first use.

program using information provided by the manufacturer.

New lessons plans will be developed to train workers on Mururoa's features, donning, use and removal, cautions, and use of mouth NLS2005029-02 Prior to first use.

strip and tear off strips for routine and emergency egress.

Radiation Protection personnel will be provided additional training for selection, approval, issue, equipment set-up, operation NLS2005029-03 Prior to first use.

and maintenance instructions for the Mururoa suit.

NPPD will report any defects of these suits in a timely manner to the United States nuclear industry through our Operating NLS2005029-04 Prior to first use.

Experience process and to the manufacturer.

All instructions for use and emergency features supplied by the manufacturer will NLS2005029-05 Prior to first use.

be included in our procedures/training.

NPPD understands that this is a single use suit and will discard each suit after a single NLS2005029-06 Prior to first use.

use.

PROCEDURE 0.42 REVISION 18 PAGE 19 OF 25

NLS2005029 Attachment I Page I of 8 APPROVAL REQUEST FOR DELTA PROTECTION MURUROA SINGLE USE ENCAPSULATING SUITS

1.0 INTRODUCTION

2 1.1 PURPOSE.......................................................................

2

1.2 BACKGROUND

...................................................................... 2 1.2.1 Regulatory Requirements.......................................................................

2 1.2.2 Suit Construction......................................................................

3 1.2.3 Safety Features of the Mururoa Model V4 MTH2 Suit................................ 4 1.2.4 Implementation......................................................................

5 2.0 TECHNICAL JUSTIFICATION.............................

5 2.1 EVALUATION....................................................................... 5 2.2 PRECEDENTS.......................................................................

6

3.0 CONCLUSION

7

4.0 REFERENCES

........................................................................................7 5.0 ENCLOSURES 5.1 GENERAL DESCRIPTION OF THE DELTA PROTECTION SUPPLIED AIR SUIT.

5.2 EUROPEAN STANDARD EN 1073-1 FOR PROTECTIVE CLOTHING AGAINST RADIOACTIVE CONTAMINATION 5.3 CERTIFICATE NO. 0073/197/162/01/96/0001 FOR MURUROA V4 MTH2 ISSUED BY THE INSTITUTE FOR NUCLEAR PROTECTION AND SECURITY 5.4 PROTECTION FACTOR DETERMINED DURING FIT TEST EXERCISES FOR MURUROA V4 MTH2 5.5 DONNING AND REMOVAL INSTRUCTIONS FOR MURUROA V4 MTH2

NLS2005029 Attachment I Page 2 of 8

1.0 INTRODUCTION

1.1 PURPOSE Nebraska Public Power District (NPPD) proposes the use of the Mururoa "fully enclosed suit" model V4 MTH2 manufactured by Delta Protection, France. The purpose of this submittal is to request approval for the use of these particular suits and for authorization to use an Assigned Protection Factor (APF) of 2000 when using the suits. 10 CFR 20, Appendix A, "Assigned Protection Factors for Respirators", states that an air-supplied suit may be used in a continuous-flow mode, however, an APF has not been designated.

A footnote to this equipment application indicates that the suit can be used in a respiratory protection program if the minimum program requirements are met (e.g., 10 CFR 20.1703, "Use of Individual Respiratory Protection Equipment). 10 CFR 20.1703 states that use of respiratory protection equipment that has not been approved by the National Institute for Occupation Safety and Health (NIOSH) is acceptable only if approved for use by the Nuclear Regulatory Commission (NRC).

Additionally, due to the advanced safety features for emergency breathing and emergency escape built into these suit models, NPPD may choose to use the Mururoa suits without dedicated rescue personnel being assigned.

NPPD will document and evaluate any unexpected problems with the suits in the Corrective Action Program (CAP). The manufacturer is subjected to checks from the IPSN (Institute for Nuclear Protection and Security) to ensure the product has no risk of injury to the user. A second organization called ASQUAL (an advisory group to regulators) performs annual inspections of the factory to certify that the manufactured product is of the same quality approved by the IPSN. Several destructive and non-destructive tests are performed by the manufacturer for each order received from clients.

Any defects reported by clients, investigations, and corrective actions are documented by Delta Protection. Customers are notified of significant problems and products are recalled if necessary. This information is made available to ASQUAL for their annual inspections. In addition, NPPD will report to the manufacturer and the industry any deficiencies, or defects in the product, should they arise.

1.2 BACKGROUND

1.2.1 Regulatory Requirements The following regulatory requirements are relevant to this request.

NLS2005029 Attachment I Page 3 of 8 10 CFR 20.1703, "Use of Individual Respiratory Protection Equipment", requires that if a licensee assigns or permits the use of respiratory protection equipment to limit the intake of radioactive material, (a) the licensee shall use only respiratory protection equipment that is tested and certified by NIOSH.

10CFR20.1703(b) allows that if the licensee wishes to use equipment that has not been tested or certified by NIOSH, or for which there is no schedule for testing or certification, the licensee shall submit an application to the NRC to authorize use of the equipment.

10 CFR 20.1705, "Application for Use of Higher Assigned Protection Factors",

states that a licensee shall obtain authorization from the NRC before using assigned protection factors in excess of those specified in 10 CFR 20, Appendix A, except as otherwise noted in this part.

10 CFR 20, Appendix A, "Assigned Protection Factors for Respirators", Item II, "Atmosphere Supplying Respirators (particulate, gases and vapors)", indicates that for a suit in a continuous flow operating mode, no APF is assigned, nor is a NIOSH approval schedule currently available for the evaluation of atmosphere supplying suits. This equipment may be used in an acceptable respiratory protection program as long as all the other minimum program requirements, with the exception of fit testing, are met (i.e., 10 CFR 20.1703).

Based on these regulatory requirements, NPPD is required to obtain NRC approval for both the use of the Mururoa model V4 MTH2 suit and a protection factor for this use.

1.2.2 Suit Construction The Mururoa Model V4 MTH2 suit meets ISO 8194 and the European Standard EN.NF 1073-1. The manufacturer is ISO 9002 certified.

The Mururoa single use suits have the following desirable features:

1)

One piece single use suit that includes welded gloves and booties with tie

straps,
2)

Made of Ethyfuge with reinforced elbows, knees and crotch areas,

3)

Dual zippers - metal zipper inside and plastic zipper outside,

4)

Helmet made of clear Poly Vinyl Chloride (PVC) material that provides distortion-free vision and large enough for wearing a headset,

5)

Welded sleeve to insert communication cable,

NLS2005029 Attachment I Page 4 of 8

6)

A removable strip near the mouth that could be used for emergency breathing in case of loss of supplied air,

7)

An egress strip stretching from left arm, over the head, to right arm that is used for undressing and for self-rescue in an emergency, such as loss of supplied air,

8)

Air intake located at the waist with a built-in regulator that can adjust, but not block, airflow,

9)

Two exhaust valves that provide ventilation and protection from overpressure,

10)

Very low noise level at maximum air flow,

11)

Airflow to the arms, legs and face.

12) Air hoses of any length can be used, but air shall be supplied to the Mururoa suits at 85 psig +/- 10%, measured at the inlet.

A regulator at the inlet can adjust the airflow from 43 cubic feet per minute (CFM) maximum to 20 CFM at the minimum. To ensure user safety, the regulator cannot shut off the air supply. Noise level is kept between 76 dB at maximum airflow to 58 dB at minimum airflow. Air flows through manifolds to the chest, hands and feet. Examination of the suit shows there are two air vents near the chin for cooling the face, as well as a distribution network for air to go to the arms and the legs. There are two exhaust vents on the back - one behind the neck and one at lower back. The exhaust vents have patented magnetic seals to prevent any aspiration of contaminants if supplied air is lost. The Mururoa is approved for use with different fittings in Europe and can be fitted with a variety of fittings; e.g.

snap-tite fittings, used at the NPPD facilities. The Mururoa Model V4 MTH2 suit is made of Ethyfuge material, which can be incinerated.

1.2.3 Safety Features of the Mururoa Model V4 MTH2 Suit All Mururoa suit models are lightweight (2.5 Ibs), made of fire-retardant material and can be used in temperatures up to 1400 F., as per EN 1073-1. The suits have built-in gloves, booties with binding ties, and reinforced elbows, knees and crotch. A transparent helmet with 6-inch X 8-inch clear faceplate provides distortion-free view. Dual magnetic ventilation valves provide needed ventilation and relief of excess pressure in case suit is squeezed or pinched unexpectedly.

Noise level at maximum airflow is less than 80 dB. Airflow can be adjusted by the user for their comfort, but cannot be shut off. In case of loss of air, the user can remove the mouth strip and move the opening close to his face, or enlarge the opening, to breathe outside air. Alternately, the user can pull the escape strip from either forearm, over the head and towards the other forearm, and rip the suit

NLS2005029 Attachment I Page 5 of 8 in two halves. This escape strip is normally used for egress from the suit when the work activity has been completed.

The Mururoa suit's design does not permit its use in an Immediately Dangerous to Life and Health (IDLH) atmosphere. NPPD plans to use this suit for protection against radioactive particulate contamination only. The Mururoa suit is also not designed for use with any personal cooling units such as a Vortex tube, but can be used with a cooling vest supplied by the manufacturer, if desired.

1.2.4 Implementation NPPD has a respiratory program at Cooper Nuclear Station (CNS) that is in full compliance with 10 CFR 20. The Mururoa V4 MTH2 suit will be integrated into the CNS respiratory program using the information provided by the manufacturer.

New lesson plans will be developed to train workers on the Mururoa's features, donning, use and removal, cautions, use of mouth strip, and tear off strips for routine and emergency egress. Radiation Protection personnel will be provided additional training for selection, approval, issue, equipment set-up, operation, and maintenance instructions for the Mururoa suit. The Mururoa suit's safety features, namely the tear-off mouth strip and the emergency tear-off strip, make it unnecessary to provide standby rescue personnel. Additionally, in many cases, workers are in direct contact with Radiation Protection or support personnel via audio headsets. The ability to eliminate the rescue worker is an ALARA (As Low As Reasonably Achievable) consideration since the work areas where air-supplied suits are used are typically areas with higher radiation and contamination levels.

Reactor cavity decontamination, CRD pulls, and equipment decontamination are specifically targeted for the use of the Mururoa suit.

2.0 TECHNICAL JUSTIFICATION 2.1 EVALUATION NPPD reviewed the following documents obtained from Delta Protection:

  • General Description of the Mururoa Model V4 MTH2 Ventilated Suits (Enclosure 5.1),

European Standard EN 1073-1:1998 for Ventilated Protective Clothing (Enclosure 5.2),

Certificate No. 0073/197/162/01/96/0001 for Mururoa Model V4 MTH2 Issued by the Institute for Nuclear Protection and Security (Enclosure 5.3),

NLS2005029 Attachment I Page 6 of 8

  • Protection Factor Determined During Fit Test Exercises for Mururoa Model V4 MTH2 (Enclosure 5.4), and
  • Donning and Removal Instructions for Mururoa V4 MTH2 (Enclosure 5.5).

Based on a review of this documentation, the suits represent a better design than the currently approved "bubble hood" and "rain suit" combination and provide better worker protection with the data supporting an APF of at least 2000.

A key element of this review was the application of the European Standard and the Certificate issued by the Institute for Nuclear Protection and Security for the Mururoa suits. The European Standard (Enclosure 5.2) requires that the suit material be tested for resistance to abrasion, flex cracking, puncture, blocking, tear and flammability, strength of seams, joints and assemblies, damage resistance of exhaust valves, designed flow rates for pressure range of supplied air, noise level, and quality of the visor. According to the testing standard, three workers should perform standard exercises, each wearing two different suits inside a chamber filled with a test agent (Sodium Chloride) and measure the leakages during the exercise regimen lasting 20 minutes. Operating parameters are set to manufacturer's instructions. Standard exercises include walking on a treadmill at 2 mph (3 minutes), moving arms up and down above head while looking upward (3 minutes) and squatting continuously (3 minutes). To ensure worker's comfort, two additional practical exercises - walking at 2 mph (5 minutes) and loading a bucket with wood chips from the base of a hopper and emptying it into the opening on top (15 minutes) - should be performed by two workers at specified air flow rates. Certificate No. 0073/197/162/01/96/0001 (Enclosure 5.3) states that the Mururoa Model V4 MTH2 passed in all categories tested and provided a protection factor greater than 50,000. It should be noted that the term protection factor used in the European Standard is equivalent to the fit factor used in the United States and is not the same as the Assigned Protection Factor used in 10 CFR 20.

NPPD currently uses air supplied hoods (commonly known as the bubble hood) for jobs involving overhead contaminated water, high potential for skin contamination from discrete radioactive particles, and to prevent intake of airborne contaminates. Because the bubble hoods do not cover the hands and the feet, workers have to wear additional protective clothing, including two pairs of gloves, rubber shoes and booties and tape for sealing. Chances of cross contamination during undressing and exit from the contaminated areas are high. The Mururoa suits offer a better alternative (with their unitized construction and ease of removal) and should protect the worker much better against facial and/or skin contamination and airborne radioactivity. Approval of a protection factor of 2000 for the Mururoa suits would allow use of the Mururoa suits in NPPD efforts to control contamination incidents and prevent intakes during operational activities.

NLS2005029 Attachment I Page 7 of 8 2.2 PRECEDENTS I) The NRC authorized the Mururoa suit June 30, 2003 for use by the Duke Energy Corporation as a respiratory device with a protection factor of 2000 (TAC NOS. MB 7952, MB7953, MB7954, MB7955, MB7956, MB7957, and MB7958).

2) The NRC authorized the Mururoa suit February 1, 2005 for use by Entergy Operations at ANO I & 2, Grand Gulf, River Bend, and Waterford as a respiratory device with a protection factor of 2000 (TAC NOS MC5363, MC5364, MC5365, MC5366, and MC5367).
3) The NRC authorized the Mururoa suit April 8, 2005 for use by Florida Power and Light Company as a respiratory device with a protection factor of 5000 (TAC NOS MC5816, MC5817, MC5818, MC5819 and MC5820).
4) The NRC authorized the Mururoa suit October 24, 2005 for use by TVA as a respiratory protection device with a protection factor of 2000 (TAC NOS MC6995, MC6996, MC6997, MC6998, MC6999, and MC7000)
5) The NRC authorized the Mururoa suit September 14, 2005 for use by Union Electric Company as a respiratory protection device with a protection factor of 5000 (TAC NO MC7242)
6) The NRC authorized the Mururoa suit September 22, 2005 for use by PPL Susquehanna, LLC as a respiratory protection device with a protection factor of 2000 (TAC NOS MC5634 and MC56535)
7) The NRC authorized the Mururoa suit September 29, 2005 for use by TXU Power as a respiratory protection device with a protection factor of 5000 (TAC NOS MC8303 and MC8304)

3.0 CONCLUSION

NPPD requests NRC approval for use of the suits pursuant to 10 CFR 20.1703(b). Based on the review of industry and manufacturer test documentation, NPPD has determined that the Mururoa model V4 MTH2 air supplied suits offer a safer and more efficient means to protect workers in areas of either high radiological contamination and/or high potential for airborne contamination.

NLS2005029 Page 8 of 8

4.0 REFERENCES

1. 10 CFR 20.1703, "Use of Individual Respiratory Protection Equipment"
2.

10 CFR 20.1705, "Application for Use of Higher Assigned Protection Factors"

3.

10 CFR 20, Appendix A, "Assigned Protection Factors for Respirators"

4. European Standard EN 1073-1 (January 1998)
5. EC Type Examination Certificate No. 0073/197/162/12/96/0001 for the V4 MTH2 suit dated January 10, 1996

NLS2005029 ENCLOSURE 5.1 Page I of 6 GENERAL DESCRIPTION OF THE DELTA PROTECTED SUPPLIED AIR SUIT

NO: Do / USA /1 MURUROAA INDICE: a V4 FULLY ENCLOSED SUIT PROTEC..

OIJ DATE D'APPLICATION :06/09/01

11.1-1-11....

RO alO GENERAL DESCRIP11ON A 04 66 89 18 36 PAGE :1/4 MURUROA SUIT The Mururoa suit is a single use garment designed to be used in radioactively contaminated environments. It has been widely used in western European Nuclear Power Plants for more than 20 years, without any major problem (the French state company: ElectricitM de France use 60,000 garments each year).

The Mururoa suit is a fully enclosed PVC plastic, supplied-air and pressurized suit, that offers excellent protection factor ( -100,000) against any solid, liquid, or gas pollutant, minimizing discomfort and heat stress and increasing the worker's efficiency.

The Mururoa suit is C.E. approved and complies with CE standard EN:1073-1 "Protective clothing against Radioactive Contamination" It also fulfils the requirements of the I.S.O. 8194 standard "Radiation Protection-Clothing for protection against Radioactive contamination-Design selection testing and use"

N*: Do / USA /1 MURUROA INDICE a V4 FULLY ENCLOSED SUIT DELT PROTECMIA DATE D'APPLICATION :06/09/01

...B

................ In......

GENERAL DESCRIP11ON

\\

4 66 89 18 36 PAGE :2/4 VENTILATION / EXHAUST In the supplied-air Mururoa suit, the ventilation system is composed of An airflow control valve, preset to a minimum flow of 250 litres/minute (9 CFM) at 3 bar (42 PSIG), located on the right hip and covered with a protection flap. This flow can be adjusted, from 250 to 1150 litres (9 CFM to 41 CFM) per minute. 1150 litres is obtained with the tap fully opened at the feeding pressure of 6 bar (85 PSIG) (refer to graph in annex 11).

A silencer bag which attenuates the noise level less than 58 dBa at 250 litres/minutes to 76 dBa at 1150 litres/minute.

A manifold system welded to the suit and distributing the air to the helmet, the legs and the arms.

An exhaust by two world patented valves placed in the helmet and in the back. These valves ensure a remarkable airtight seal in case of accidental air-feed cut off, or when putting the suit in under pressure through abrupt movements. The valves regulate the overpressure in the garment between 3 mbar (0.042 PSIG) and 10 mbar (0. 142 PSIG) for supply air pressure between 3 bar (42 PSIG) and 6 bar (85 PSIG)

The benefits of this system are

- High heat removal through superior airflow

- Non irritating diffuse ventilation

- Resistance free breathing

- High level of comfort for long and strenuous jobs in contaminated areas

- Very low noise level

N0: Do / USA /1 MURUROA.........

INDICE: a V4 FULLY ENCLOSED SUIT DATE D'APPLICATION :06/09/01 GENERAL DESCRIPION E04 66 89 18 36 PAGE :3/4 DESIGN CHARACTERISTICS One piece PVC, fire proof suit. (Thickness 20/100mm for technical data concerning the material, refer Annex I of this document)

Welded PVC gloves Incorporated overboots with strengthened sole Binding ties on the overboots Reinforced elbows, knees and crotch Dual zipper system:

- metal zipper for mechanical strength

- PVC zipper for air and gas tightness (0.30 PVC thickness)

Supple transparent PVC helmet, fitted with a transparent distortion free, PVC face plate 6x 8" giving almost the same optical quality as glass.

Quick release strip from forearm, overhead to forearm, for easy removal. This is used both for undressing or emergency egress. (Emergency egress takes less than 3 seconds).

Quick release strip for access to the mouth.

Welded sleeve for communication cable.

NO: Do/USA/1 MURUROA i.

INDICE: a V4 FULLY ENCLOSED SUIT DATE D'APPLICATION :06/09/01 G.ENERAL DESCRI.P11 ON 4 66 89 1836 PAGE :4/4 GENERALCONSIDERATIONS THE MURUROA SUIT IS AVAILABLE IN SIX SIZES Size 0 1,55 m e

1,62 meter 5 feet I inch e

5 feet 4 inches Size 1 1,60 e

1,68 meter 5'3"

-e 5'6" Size 2 1,68 e

1,74 meter 5'6"

-e 5'8" Size 3 1,74 1,82 meter 5'8"

-e 6'0" Size 4 1,82 e

1,92 meter 6'0" e

6'3" Size 5 1,92 e

2,05 meter 6'3" e

6'8" But if any individual selects a suit size different from the recommended size, the operating and safety characteristics will not change.

WEIGHT 1200 grams (2.64 LBS)

FEEDING PRESSURE 6 bar (85 PSIG)

FLOW 450 up to 1150 Lit/minute (16 - 41 CFM)

STORAGE The suit should be used by the third year from the date of manufacture.

It must be stored in its original packaging.

The storage temperature has to stay between 0C and 600C (320F - 1400F)

If the storage temperature was below 5OC (41 OF) the suit must be stored approximately 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> at a room temperature until the suit become flexible.

The usage temperature range + 50 C and + 550C (410 - 1310F) depends on air fed temperature

N*: Do/USA/1 MURUROA INDICE: a V4 FULLY ENCLOSED SUIT DATE LAAPPLICATION

06/09/01 L

PROTEC GENERAL DESCRIPTION we 04 66 89 18 36 PAGE :5/4 MATERIAL PROPERTIES Technical characteristic of PVC material 20/100 mm using French standards, which would correspond to ANSI standards.

Characteristic Standards Results Units Density NFT 51063 1.38 gm/cm3 Traction Resistance NFT 54102 2 143 N/cm2 Stretch before tear NFT 54102 2 178 Tear resistance NFT 46007 2 45 N/cm2 Weld resistance than material resistance NFT 54122 Peel 50 l

Tear65 Resistance to cold NFT 51102

-10 0C Vapour permeability NFH 00030 34.1 g/m2/24h Volatility on activated charcoal NFT 51167

< 6 Spark perforation NFC 26225 9.2 KV

NLS2005029 ENCLOSURE 5.2 Page I of 13 EUROPEAN STANDARD EN 1073-1: PROTECTIVE CLOTHING AGAINST RADIOACTIVE CONTAMINATION

EUROPEAN STANDARD NORME EUROPEENNE EUROPEAISCHE NORM EN 1073-1 January 1998 ICS 13.280; 13.340.10 Descriptors: Personal protective equipment, clothing, radioactive contamination.

English version Protective clothing against radioactive contamination Part 1: Requirements and test methods for ventilated protective clothing against particulate radioactive contamination Vetements de protection contre la contamination radioactive - Partie 1:

Exigences et methodes d'essal des vOtements contre la contamination radioactive sous forme de particules Schutzkkeldung gegen radioaktive Kontamination -Tell 1: Anforderungen und Priifverfahren fur belriftete Schutzkleidung gegen radioaktive Kontamination durch feste Partikel This European Standard was approved by CEN on 1997-11-23. CEN members are bound to comply with the CENICENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member.

The European Standards exist in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member Into its own language and notified to the Central Secretariat has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, the Czech Republc, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom.

CEN European Committee for Standardization Comite Europeen de Normalisation Europaisches Komitee fur Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels 0 1998.

CEN - All rights of exploitation In any form and by any means reserved worldwide for CEN national members.

Ref. No. EN 1073-1 :1998 E

Page 2 EN 10731 :1998 Contents Foreword....................................................................................................

I Scope 2

3 2 Normative references.............................................................................

3 Definitions................................................................................................

4 Requirements............................................................................................

5 Test m ethods 6 M arking 7 Information suppled by the manufacturer.

Annex A (normative)

Activity sequence for the testing of the protection factor...........................

Annex ZA (informative)

Clauses of this European Standard addressing essential requirements or other provisions of EU Directives.......................................................................

3 3

4 8

10 10 11 12 Foreword This European Standard has been prepared by Technical Commiltee CENITC 162 'Protecive clothing Including hand and arm protection and lifejackets". the secretariat of which Is held by DIN.

This European Standard shall be given the status of a national standard, either by publication of an Identical text or by endorsement, at the latest by July 1998, and conflicting national standards shall be withdrawn at the latest by July 1998.

This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports essential requirements of EU Directive(s).

For relationship with EU Directive(s), see Informative Annex ZA, which Is an Integral part of this standard.

The annex A Is normative and contains the activity sequence for the testing of the protection factor.

Further parts of this standard WiN deal with requirements and test methods for unventilated protective clothing and protection against [quids and gases.

According to the CENICENELEC Internal Regulations, the national standards organizations of the following countries are bound to Implement this European Standard: Austia, Belgium, Czech Repubic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy. Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.

Page 3 EN 1073-1 :1998 1 Scope This European Standard specifies the requirements and test methods for ventilated protective clothing protecting the wearer against particulate radioactive contamination.

This European Standard does not apply for the protection against ionizing radiation and the protection of patients against contamination with radioactive substances by diagnostical and/or therapeutical measures.

2 Nonnative references This European standard Incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places In the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.

EN 146 Respiratory protective devices - Powered filtering devices Incorporating helmets or hoods - Requirements, testing, marking EN 270 Respiratory protective devices - Compressed air line breathing apparatus Incorporating a hood - Requirements, testing, marking EN 340 Protective clothing - General requirements EN 530 Abrasion resistance of protective clothing material - Test methods EN 863 Protective clothing - Mechanical properties - Test method: Puncture resistance prEN 943-1 Protective clothing for use against liquid and gaseous chemicals, including liquid aerosols and solid particles -

Performance requirements for ventilated and non-ventilated "gas-tightV (Type 1) and 'non-gas-tightr (Type 2) protective clothing EN 1146 Respiratory protective devices for self-rescue - Self-contained open-circuit compressed air breathing apparatus Incorporating a hood (compressed air escape apparatus with hood) - Requirements, testing, marking EN 25978 Rubber-or plastics-coated fabrics - Determination of blocking resistance (ISO 5978: 1990)

EN 29073-4 Textiles - Test methods for nonwovens - Part 4: Determination of tear resistance ISO 5082: 1982 Textiles - woven fabrics - Determination of breaking strength - Grab method ISO 7854 Rubber-or plastics-coated fabrics - Determination of resistance to damage by flexing 3 Definitions For the purposes of this standard, the following definitions apply:

3.1 Protective clothing against radioactive contamination Protective clothing Intended to provide protection to the skin and if required to the respiratory tract against radioactive contamination.

Page 4 EN 1073-1 :1998 3.2 Ventilated protective clothing (against particulate radioactive contamination)

Protective clothing which Is supplied with breathable air ensuring Internal ventilation and overpressure. This protective clothing provides protection against particulate radioactive contamination for the respiratory tract and the whole body.

3.3 Nominal protection factor (100: Inward leakage (IL))

The ratio of the concentration of contaminant in the ambient atmosphere to the concentration of the contaminant In the suit. The concentrations taken Into account are the average concentrations recorded during a standardized test.

3.4 Paniculate radioactive contamination Presence of radioactive substances in or on a material or In a place where they are undesirable or could be harmful.

3.5 Seam A permanent fastening between two or more pieces of protective clothing material.

3.6 Assemblage A permanent fastening between two or more different garments, or between protective dothing and accessories, obtained, for example by sewing, welding, vulcanising, gluing.

3.7 Join A non-permanent fastening between two different garments, or between protective clothing and accessories.

3.8 Closure A device, for example, zipper, 'touch and dose" fastener, etc., to close openings for donning or removing the protective clothing.

4 Requirements 4.1 Design 4.1.1 Protective clothing against radioactive contamination shall comply with the general requirements specified In EN 340.

4.12 The design of the protective clothing shall be such that the protective clothing is straightforward to put on and take off, and to minimize the risk of contamination. Testing according to "practical performance tesr (see 5.2).

4.1.3 The clothing can be designed for single or multiple use.

4.1.4 The ventilated protective clothing (see 3.2) may consist of one or several parts. The clothing may be fitted with a respiratory protective device to enable the wearer to breath In case of failure of the primary air supply.

4.2 Materials The materials used for protective clothing against particulate radioactive contamination shall meet the requirements according to table I after the pretreatment In accordance with 5.1.1 and after the conditioning according to 5.1.2.

Page 5 EN 1073-1 :1998 Table 1: Requirements for the materials Applicableafor Requirement Classification Test according to reusable single use materials 6 > 2000 Cycles EN 530, Method 2 00 5r> 1 500 Cycles abrasrve paper Arasistn~

3>

5000 Cycles according to prEN 943-yesye 2 >

100 Cycles 1 and 9 kPa downward I >

10 Cycles pressure 6> 100 Cycles 6 > 100000 Cycles 5 >

40000 Cycles Flex cracking 4>

1 5000 Cycles ISO 7854 Method B yes no resistance 3>

5000 Cycles 2 >

2500 Cycles 1 >

I000Cycles Puncure3 >

lOO N resistance 2>

SON EN 863 yes yes reIta ION Resistance to 2 no blocking EN 25978 yes no blocking (see note 1) 1 blocking 6>

150N 5>

80N Tear resistance 4>

40 N EN 29073-4 yes yes 3>

20N 2>

ION 1 >

2N Flammability of Shag not continue to EN 1146 (single materalas, visor and bum burner test) yes yes ancillary parts NU I t: 1: uncoatea matenals snall not De tested against resistance to Dlocling. T he test report shall be marked 'Not tested against..........

NOTE 2: If protection against hazardous chemicals Is required then testing has to be carried out according to the relevant chemical standards.

4.3 Nominal protection factor (100:1L)

Ventilated protective clothing shall be classified according to table 2. Testing according to 5.4 with the necessary activity sequence according to annex A, at the minimum design air flow rate.

Page 6 EN 1073-1 :1998 Table 2: Leakage Class Maximum value of mean Inward leakage into the Nominal protection hood during exercise of factor One activity All activities 5

0,004 0,002 50000 4

0,01 0,005 20000 3

0,02 0,01 10000 2

0,04 0,02 5000 0,10 0,05 2000 NOTE 1: Maximum value Is calculated as the average performance over all test sequences. NOTE 2: Nominal protection factor Is the reciprocal of the IL obtained during all activities (100: IL) 4.4 Seam strength, Joins and Assemblages 4.4.1 Seam strength A sample of each type of straight seam construction shall be tested In accordance with A.2 of ISO 5082

1982 (Constant-rate-of-traverse). Three specimens of each type of seam shall be tested and the mean of each set of three samples calculated. The garment seam performance shall be classified according to the levels of performance given In table 3 using the lowest result, I.e. the weakest seam type.

NOTE: The test method described In ISO 5082: 1982 Is only applicable to straight seams Joining two pieces of material.

Table 3: Classification of seam strength Seam strength Class__

N 5

>300 4

>125 3

> 75 2

>50 1

i

>30 4.4.2 Joins and assemblages The Joins and assemblages between the suit and detachable parts e.g. between gloves and sleeves, boots and trouser legs, shall be tested In accordance with 5.5 and withstand a pull of 100 N.

4.5 Visor The visor shall comply with table 4. Where antifogging compounds are used or specified by the manufacturer they shall not have an adverse affect on the health of the wearer, or on the clothing.

Page 7 EN 1073-1:1998 Table 4: Requirements for the visor Properties of the visor Requirement Testing the loss of sight shall not exceed to read letters on a chart at a Distortion of vision two scales on the optometrical distance of 5 m during the practical chart performance test according to 52 shall not be visibly damaged in Mechanical strength such a way as to be likely to affect according to EN 146 the performance of the suit system 4.6 Air supply system Couplings and connections shall comply with EN 270.

The connection between the compressed air supply tube and the suit, Including attachments, threaded parts, belt or other parts, or means of stabilising the suit to the body shall withstand a 250 N pull when tested according to 5.5.

NOTE: The test should be performed before the inward leakage test.

4.7 Breathing hose The breathing hose shall comply with the requirements of EN 270.

4.8 Air flow rate Two suit systems shall be tested, one of which has to be preconditioned as specified in 5.1.4. When tested the air flow rate into the suit system shall not be less than the manufacturers' minimum design flow rate. The maximum flow rate shall not exceed the maximum as stated by the manufacturer. Test in accordance with 5.3 The flow rate and the distribution of the air Into the suit system shall not cause distress to the wearer by local cooing. The heat stress has to be considered. Test In accordance with 52.

4.9 Air flow rate warning device If an audible warning device Is Incorporated in the suit system it shall comply to EN 270, except for the sound pressure level which may be In the range 85dB(A) to 90 dB(A) when measured at the ears of the wearer. The frequency range of the warning device shall be between 2 000 Hz to 4 000 Hz.

Five warning devices shall be tested, one of which has to be preconditioned as specified in 5.1.4. Testing according to EN 270.

4.1 0 Supply valve If a variable continous flow valve Is fitted, it shall comply to EN 270. The valve shall permit to adjust the air flow rate In the range from the minimum to the maximum as specified In 4.8. It shall not be possible to close the valve to restrict the air flow below the minimum design air flow rate.

4.11 Exhaust devices The suit shag be provided with exhaust devices which shall continue to work correctly after the testing of the pressure in the suit (see 4.1 2), during the practical performance test (see 52) and during the determination of the protection factor (see 5.4). Testing In accordance with 5.6.

4.12 Pressure In the suit The overpressure shall not exceed 1 000 Pa mean and 2 000 Pa peak. A positive pressure shall be maintained.

Testing with the maximum air flow rate during the activity sequence as specified In Annex A.

4.13 Carbon dioxide content of the inhalation air The carbon dioxide content of the Inhalation air, determined at the minimum air flow rate, shall not exceed an average of 1,0 % (by volume), tested according to EN 270. Two suits shall be tested, one of which has to be pretreated as specified In 5.1.1.

Page 8 EN 1073-1: 1998 4.14 Noise associated with the air supply to the suit The noise measured in the suit at the ears shall not exceed 80 dB(A) at the maximum manufacturers' design flow rate. Testing in accordance with EN 270. Two suits shall be tested, one of which has to be pretreated as specified In 5. 1.1.

5 Test methods 5.1 Test preparations 5.1.1 Pretreatment When the clothing Is intended to be reusable the requirements for the materials or the complete clothing shall be proved after five cycles of cleaning and disinfection according to the manufacturer's Instructions for use before testing.

5.1.2 Conditioning All material samples shall be conditioned by storage at (20

  • 2) 'C and (65 i 5) % relative humidity for at least 24 h. Start each of the tests as specified In 5.1.3 and 5. 1.4, within 5 min after removal from the conditioning atmosphere.

5.1.3 Visual Inspection A visual inspection shall be carried out by the test house prior to the laboratory or the practical performance test. This may entail a certain amount of dismantling of the components of the protective clothing in accordance with the manufacturer's Information for maintenance.

5.1.4Preconditioning for the practical performance test If the manufacturer does not state the preconditioning atmosphere for the practical performance test, the complete clothing shall be exposed:

a) for 4 h to a temperature of (-30 +/- 3) "C and allowed to return to ambient conditions, followed by b) for 4 h to an atmosphere of (60 +/- 3) "C at 95 % relative humidity. It shall then be allowed to return to ambient temperature.

6.2 Practical performance test 6.2.1 GeneM!

The tests shall be carried out by two test persons at (20* 5) "C and a relative humidity of less than 60 %. The test temperature and humidity shall be recorded. The background noise shall not be greater than 75 dB(A).

The test persons shall be selected who are familiar with using such or similar protective clothing. The persons will be drawn from those people certified as fit to do so by the medical officer. The necessity of a medical examination before or supervision during the tests shall be at the testing officers discretion.

Prior to the test there shall be an examination that the suit is in working-condition and that It can be used without danger. If more than one size of clothing Is manufactured the subjects are asked to select the appropriate size. Ensure that the air supply Is within the specified parameters. Two suits shall be tested, each being tested on one test person.

After fitting the suit each test person Is asked "Does the suit fit?", If the answer Is "Yes", continue the test. If the answer is "No. replace the test person or the suit.

5.2.2 Procedure During the test the following activities shall be done In simulation of the practical use of the suit:

a) the test shall be completed within a total working time of 20 min b) walking on the level with regular rate of 5 kmlh for 5 min

Page 9 EN 1073-14:1998 c) filling a small basket (see figure 1, approximate volume 8 1) with 12 mm chippings (e.g. limestone chippings) or other suitable material from a hopper which stands 1,5 m high and has an opening at the bottom to allow the contents to be shovelled out and a further opening at the top where the chippings may be returned. The person stoops or kneels as he wishes and fills the basket with chippings. He then lifts the basket and empties the contents back into the hopper. This shall be repeated 1 5 to 20 times In 10 min.

Figure 1: Hoppor and basket 5.2.3 Information to be recorded During the practical performance test the clothing shall be subjectively assessed by the wearer and the following shall be recorded:

a) harness comfort (see 5.6);

b)security of fastening and couplings; c) accessibility of controls and pressure gauge (if fitted);

d)clarity and field of vision from the facepiece and/or visor, e) clothing comfort;

1) ease of speech transmission; g)any other comments volunteered by the wearer.

5.3Measurement of minimum and maximum airflow rate Connect the ends of the distribution system collectively to a suitable measuring device. Record the maximum air flow delivered at the manufacturers' specified air supply, If a control valve Is fitted, record the maximum delivered air flow and the minimum delivered air flow.

The value of minimum and maximum air flow rate shall be determined under the condition of exercise 6 of Annex A (person standing still).

5.4Determlnation of the protection factor The protection factor shall be determined In accordance with prEN 943-1. Sodium chloride test method shall be used. Activity sequences for testing are given In Annex A of this standard.

The determination has to be done at the minimum design air flow rate (see 4.8).

On two test subjects four new suits shall be tested. Two suits per test subject.

Page 10 EN 1073-1 :1998 For each individual test calculate the arithmetic mean over the time period. Calculate the percentage Inward leakage (IL) as follows: -

IL Cat x 100%

C.

where:

C, Is the challenge concentration In the test chamber, C2 is the mean concentration In the breathing zone for each exercise. For classification according to table 2, the average value for the four suits shall be taken.

5.5 Join and assemblage pull test Assemble the means of attachment according to the manufacturers' Information. If the assembled Item (e.g.

glove or boot) Is Itself not strong enough to apply the required pull substitute an Item that is. Securely attach one part to a fixed clamp. Apply the required force longitudinally. Record at which force It parts or state that at the required force it was still complete.

5.6 Exhaust device pull test Mount the suit on to a dummy torso which can be adjusted so that the load can be applied axially to the exhaust device. A system of retaining straps or bands Is fitted over the suit around the exhaust device so that the load Is applied as directly as possible to the fitting of the exhaust device In the suit.

Exert a force of (50 +/- 2,5) N to the exhaust device and hold for 10 s. Repeat 10 times.

Examine the exhaust device for signs of damage or failure.

6 Marking The marking shall comply with the specifications of EN 340 with the pictogram as given In figure 2.

The level of performance of the Inward leakage (IL) shall be marked as:

IL: class x (x = class number according to table 2).

as I *

.0**

Figure 2: Pictogram 7 Information supplied by the manufacturer The Information supplied shall be at least In the official language(s) of the country or region of application. The manufacturers' Information shall comply with the specifications of EN 340. The following Information shall be supplied additionally:

- Instructions for donning, using, fitting, removing and storing;

- application, limitations of use (classification, temperature range etc.);

- tests to be carried out by the wearer before use (if required);

- maintenance and cleaning and decontamination by e.g. showering (if required).

The manufacturers shall specify the required supply pressure and flow range necessary to maintain protection.

Warnings (if appropriate) shall be given against problems likely to be encountered, as e.g. heat stress, depending on the air flow rate, work load, environmental atmosphere etc.

I

Page 11 EN 1073-1:1998 Annex A (normative)

Activity sequence for the testing of the protection factor Table A.1: Activity sequence for the testing of the protection factor lime of No Activity sequence for the testing activities in 1

dress person In the suit 2

don boots, gloves etc. as required according to the manufacturers instructions 3

person to enter test chamber, connect tubing to the sample point -

no test agent 4

establish background reading at sample point with person standing 3

still - no test agent 5

start test agent and allow to stabilize 3

6 record leakage and pressure at sample point with the person stan-ding still..

7 start treadmill 8

walk 3

record leakage and pressure at sample point with the person wal-king at about 5 km/h 10 stop treadmill record leakage and pressure at sample point person mAing arms 1

up and down above head height and looking upward, e.g. lifting 3

object (half brick) from desk to shelf level 12 record leakage and pressure at sample point, person doing conti-nuous squats 13 stop test agent and allow to desperse with person in chamber 3

14 disconnect sample tubes and remove person from test chamber and undress subject NOTE: The total trial may vary, all times are approximate and are to stable conditions.

When doing squats, a slow deliberate action Is required, say continuously during about 3s.

Analyse results over final 2 min of each exercise period to avoid carry over of result from one exercise to the other.

Record challenge chemical continuously using a separate detector (if possible). Record the pressure inside the suit over the whole time.

Page 12 EN 1073-1:1998 Annex ZA (informative)

Clauses of this European Standard addressing essential requirements or other provisions of EU Directives This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports essential requirements of EU Directive 891686/EEC.

WARNING: Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this standard.

The following clauses of this standard are likely to support requirements of Directive 89/686/EEC, Annex II:

EU-Directive 8916861EEC, Annex II clauses of this standard 1.1 Design principles 4.1, 4.2, 4.3, 5.6.1 to 5.6 1.2 Innocuousness of PPE 4.1, 4.5, 4.14, 5.2 1.3 Comfort and efficiency 4.1, 4.3, 5.2, 5.4, annex A 1.4 Information supplied by the manufacturer clause 7 2.2 PPE 'enclosing' the parts of the body to be protected 4.1.4, 4.5, 4.8, 5.2 2.3. PPE for the face, eyes and respiratory tracts 4.5, 5.2 2.1 2 PPE bearing one or more identification or recognition clause 6 marks directly or indirectly relating to health and safety clause_6 3.9.2.1 Protection against external radioactive contamination clause 4, 5, 6, 7 Compliance with the clauses of this standard provides one means of conforming with the specific essential requirements of the Directive concerned and associated EFTA regulations.

NLS2005029 ENCLOSURE 5.3 Page I of 10 CERTIFICATE NO. 0073/197/162/01/96/0001 FOR MURUROA V4 MTH2 ISSUED BY THE INSTITUTE FOR NUCLEAR PROTECTION AND SECURITY

ECEC 96 / 0001 Page 1/9 INSTITUTE FOR NUCLEAR PROTECTION AND SECURITY Technical Center for Nuclear Equipment Certification In accordance with the directive 89/686/EEC dated December 21 th 1989 comparing the laws of the States Members Legislations relative to the Personal Protective Equipments, and the decrees n0 92-765, 766 and 768 dated July 29th 1992 transposing the directive into French Laws.

The organisation here below mentioned (IPSN / CTHEN) whose references are as follows:

Address: B.P. n0 6 - 92265 Fontenay-aux-Roses Cedex (France).

Empowered by Order of the Ministries of Employment and Agriculture dated December 24t 1996.

Identified under the no 0073 (published in the EEC Official Publication dated July 23 th 1994).

Assigns the:

To the following Personal Protective Equipment model:

Designation: Ventilated Protective Suit against Radioactive Contamination pressurised for a single use only.

Commercial reference: MTH 2 - ref. 841 442 T.

Manufacturer: DELTA PROTECTION / REDI - 69 210 Saint-Germain-Sur-L'Abresle.

Certificate applicant: DELTA PROTECTION - Z.A. De Berret-30200 Bagnols-Sur-Ceze.

Essential Requirements

Reference:

EN 143, pr EN 1073 (nov. 1995), pr EN 943 (august 1995), EN 270, EN 146.

Date: January 10h 1996 G.BRUHL / Chief of CTHEN Nota : According to article R 223-62 of the "Working Law", the empowered organisation should be informed of any modification made to the material subject of this EEC type examination certificate, as well as of any modification made to the contents of this technical file on which the delivered type certificate was based on (address, manufacturer name, quality insurance certificate extract,...)

This certificate contains 12 pages no 1/9 to 9/9 Frm.,c v oan orty dog be ueed vwhn d.at

ECEC 96/ 0001 Page 2/9

1. DESCRIPTION It is a Ventilated Protective Suit against Radioactive Contamination ventilated type - pressurised for a single use only, its name is:

MTH2 - ref. DELTA: 841 442 T The T values are defined according to the size of the suit.

The suit includes:

A air tight suit with an incorporated hood A suit fastening system located on the back of the suit.

A breathable air flow supply system.

A air exhaust device.

A safety strip for emergency opening located on the hood.

F-nh -vnio

  • d da. be u-d vi-do.

ECEC 96 / 0001 Page 3/9 1.1.

MAIN MATERIALS Skin of the suit:

White polyethylene: Ethyfuge 2000 Thickness: 24/1 00 mm Hood:

PE Cristal - 30/100 mm thickness.

Visor:

PVC (astraglass) 50/100 mm thickness.

Gloves:

PVC Sempersoft type - Size 9-91/2, and Semperstar type - size 10-10 0 2..

Boots:

Polyethylene - 24/1 00 mm thickness, reinforced with PE cristal.

1.2.

COMPONENTS Internal Ventilation System:

It includes a total ventilation V4 fitted with a valve with CEJN (ref:342) butt.

Exhaust:

It includes two exhaust valves located on the head and on the back of the suit.

Fastening device:

It Includes a double zip fastener located vertically on the back of the suit.

Other components:

The suit includes:

A safety strip for an emergency opening located on the hood.

A acoustic link tunnel.

A loop for breathable air supply pipe.

Several internal strengthening pieces for elbows, knees and legs.

A transparent window to visualise the dosimeter.

2.

CONFORMITY TO REQUIREMENTS 2.1.

REQUIREMENTS FOR THE MATERIALS (except accessories: Gloves, slippers...)

(See paragraph 5.1. of the prEN 1073)

Finch vent, ody XIl b. used whe fpoo

ECEC 96/0001 Page 4/9 2.1.1. Abrasion Resistance Test according to the Norm EN 530 - method 2 (abrasive paper 00). The classification is carried out according to the following diagram:

Class Number of cycles 6

> 2 000 cycles 5

> 1500 cycles 4

> 1 000 cycles 3

> 500 cycles 2

> 100 cycles 1

10 cycles Results:

Class 6 for Ethyfuge 2000 - 24/100 mm thickness.

Class 6 for PVC.

.1.2. Flex cracking Resistance Test according to the Norm ISO 7854 - method B. The classification is carried out according to the following diagram:

Class Number of cycles 6

> 100 000 cycles 5

> 40 000 cycles 4

> 15 000 cycles 3

1 5 000 cycles 2

1 2 500 cycles I

1 1 000 cycles This test is not applicable to suits for one single use only.

2.1.3. Puncture Resistance Test according to the Norm EN 863. The classification is carried out according to the following diagram:

Class Puncture resistance l

3

> 100N 2

> 50N 1

> 1ON Results:

Class 1 for Ethyfuge 2000 - 24/1 00 mm thickness.

Class 2 for PE cristal.

Frmenh wem Wy d*.1 be used wh-d a

ECEC 96/ 0001 Page 5/9 2.1.4. Resistance in blocking Test according to the Norm ISO 5978. The classification is carried out according to the following diagram:

Class Comments 2

non stick 1

sticky This test is not applicable to non-coated materials.

2.1.5. Tear Resistance Test according to the Norm ISO 9073-4. The classification is according to the following diagram:

Class Applied strength 6

> 150 N 5

> 80N 4

> 40N 3

> 20N 2

> 1ON 1

> 2N Results:.

Class 4 for Ethyfuge 2000 - 24/1 00 mm thickness.

Class 3 for PE Cristal.

2.1.6. Flammability of materials, visors, and ancillary parts Tests are carried out according to the Norms EN 1146 - single burner test (paragraph 7.5.3).

Results: Test requirements entirely fulfilled.

2.2. REQUIREMENTS FOR THE ACCESSORIES 2.2.1.Gloves The gloves set on the MTH2 ref. 841 442 T comply with the specific requirements for this type of Individual Protection Equipment, mainly to the Norm EN 421 'Protective Gloves against ionizer radiation and radioactive contamination'.

They have Special EC Examination Certificates (ECEC) based on contracted tests.

F~nh ve.cn ady du be usd whmn dspu

ECEC 96/0001 Page 6/9 2.2.2. Boots The boots are part and parcel of the suit and are made of the same constituted material.

Consequently they comply with the requirements.

2.3. REQUIREMENTS FOR THE PROTECTIVE SUIT 2.3.1. Suit Design: Practical Performance Test The Practical Performance Test is carried out according to the prEN 1073 (paragraph 6.2.).

The conditioning is according to the manufacturer directions for use.

Parameters Valuations a) Harness comfort b) Security of fastenings & couplings c) Accessibility of adjusting devices d) Clarity of vision through visor e) Suit comfort g) Other parameters Aimless Good Good Good Good No particular notice 2.3.2. Fit Factor (paragraph 5.2.2. of the pr EN 1073)

The protection factor is determined according to the PrEN 944 standard (paragraph 8.9) by respecting the sequences indicated in Annex A of the PrEN 1073.

The mean leakage value ( or inversely, the protection factor) enables a clothing classification according to the following table. The preconditioning according to the instructions for use recommendations.

Maximum accepted values, in %, of the ratio of the Ventilated average Inward Leakage inside the hood, pressurised calculated on the whole lot of suits FIT FACTOR Suit classification For One activity For all activities 5

0.004 0.002 50000 4

0.010 0.005 20 000 3

0.020 0.010 10 000 2

0.040 0.020 5 000 1

0.100 0.050 2 000 Results : The suit is classified 5.

Flinch v"me cay sha be sendwben dew

ECEC 96 / 0001 Page 7/9 2.3.3.1.

Seams, Joins and Assemblages pull test resistance 2.3.3.1.

Seams / Welds (paragraph 5.2.3.1 of the pr EN 1073)

A sample of each type of seam/weld is tested according to the Norm ISO 5082 (annex 2).

The seam performance level is according to the following classification:

Class Seam resistance (N) 5

> 300 4

> 125 3

> 75 2

> 50 1

> 30 The tests have been applied to the following welds:

Elbow and knee reinforcement Crotch assembly Belt assembly Booties assembly Results: All the welds are classified 3.

2.3.3.2.

Joins and Assemblages (paragraph 5.2.3.2. - prEN 1073)

This suit has no removable parts. This paragraph is aimless.

2.3.4 Gas tight (paragraph 5.2.4. of prEN 1073.

The test was carried out according to the EN 464 standard.The loss of pressure shall not be greater than 4 mbar in 6 minutes.

Results: Test not undertaken as the clothing is not considered as an gastight suit.

2.3.5.

Visors (paragraph 5.2.5. of prEN 1073)

The distortion of vision is measured, during the Practical Performance. The mechanical resistance test of the visor is according to the Norm EN 146 (paragraph 6.6 and 6.7.).

Results: Distortion of vision : Up to requirement.

Mechanical resistance: up to requirement.

Frwch venal owdy dT be md whA dqoi.

ECEC 96/0001 Page 8/9 2.3.6. Air supply system (paragraph 5.2.6. of the pr EN 1073)

The couplings and connections must comply with the requirements of the paragraphs 6.7.1.,

6.7.2., and 6.11.7. of the EN 270. The connection between the compressed air supply system and the suit must resist to a 250 N pull.

Result: requirement entirely fulfilled.

2.3.6. Breathing Hose (paragraph 5.2.7. of the pr EN 1073)

Tests are performed according to the EN 270 (paragraph 7.2. and 7.6). The pipes must not block the movements nor cause a rupture of the air supply during the Practical Performance Test.

Result: No constraint.

2.3.7. Air supply flow rate (paragraph 5.2.8. of the PrEN 1073)

The test is carried out according to the PrEN 1073 standard (paragraph 6.3).

Result:

Minimal flow rate:30 m3.h 1 (500 Vmin 1) for a 6 Bar supply pressure Maximal flow rate:66 m3.h 1 (1100 Vmin 1) for a 5.5 Bar supply pressure 2.3.8. Air flow rate warning device (paragraph 5.2.9. of the pr EN 1073)

If a warning is fitted, it must comply to the EN 270 (paragraph 6.13.3). The test must be carried out according to the EN 270 (paragraph 7.12). The sound level must be higher than 85 dB(A).

Result: Aimless (there is no sonic warning device).

2.3.9. Air supply valve (paragraph 5.2.10 of the pr EN 1073)

Where present, the control valve should enable a variation of flow rate between the minimum and maximum specified values without the possibility of closure.

Result: Requirements entirely fulfilled.

2.3.11.Exhaust devices (paragraph 5.2.11. of the pr EN 1073)

The exhaust devices must work correctly after the testing of the pressure in the suit, during the Practical Performance Test and during the determination of the Fit Factor. Test in accordance with the EN 1073 (paragraph 6.6.).

Results:

Good valves working.

Pull resistance superior to the fixed limit French voracn oy XdI be "ed whe, dspta

ECEC 96/0001 Page 9/9 2.3.12.Pressure in the suit During the activity sequence as specified, the overpressure shall not exceed 1000 Pa mean and 2000 Pa peak. A positive pressure shall be maintained.

Result: Requirements entirely fulfilled.

2.3.1 3.Carbon dioxide content of the inhalation air The CO2 content of the inhalation air, determined at the minimum air flow rate, shall not exceed an average of 1 % (by volume), tested according to the EN 270 (paragraph 7.15).

Result: Requirement entirely fulfilled.

2.3.14. Noise associated with the air supply to the suit (paragraph 5.2.14 - pr EN 1073)

Test according to the EN 270 (paragraph 7.16). The noise measured in the suit at the ears shall not exceed 80 dB(A) at the maximum air flow rate as indicated by the manufacturer.

Result: Requirement entirely fulfilled.

3.

CHECKINGS 3.1.

MARKING (paragraph 7 of the pr EN 1073)

The marking is satisfies the requirements of article 7 in the EN 340.

3.2.

MANUFACTURER INFORMATION (Paragraph 8 of the pr 1073)

The manufacturers information complies with the specifications in paragraph 8 of the EN 340.

They contain the instructions for use, the usage conditions and the specific limits and restraints.

3.3.

MAINTENANCE MARKING This is aimless, the suit being for one single use only.

4. CONCLUSIONS Upon presentation of the tests results, the Ventilated suit - pressurised for a single use only, MTH 2 - ref. 841 442 T is certified to ensure a protection against radioactive contamination according the following specified limits:

Minimum air flow rate:

30 m3.h 4 (500 I.min 4)

Maximum air flow rate:

66 m'.h.(1100 I.min 1)

Frwwh v.ion ally H.I b. usd wh-dupes

NLS2005029 ENCLOSURE 5.4 Page I of 4 PROTECTION FACTOR DETERMINED DURING FIT TEST EXERCISES FOR MURUROA V4 MTH2

DPEA/STESR/CTHEN/02-642 Page %

Test Results carded out on the full encapsulated suit MTH2 ref. 841442T For the EC Type Examination Certificate N00073/197/162/01/96/0001 You will find below the detailed results for this equipment in accordance with the Essential Requirements of the European Standard pr EN 1073-1 (revision Nov 1995). Other results that are not pointed out in this report are already written in the EC TYPE Examination certificate (dated December 1 0th 1997) 1 - Air Flow entering the suit when connected to a 6 bar feeding pressure (paragraph

.5.2.8. of the EC Type Examination Certificate)

Z-jsuiF Entrance valve position Air flow feeding pressure air flow (m3Ih I number-Bar I psig llmnI cfm) 1 Fully open 5,5 / 77 66/1100/ 38 I

Closed 6,0 / 87 30/ 500/ 17 2

Fully open 5,5 / 77 65/ 1080 /37,8 2

closed 6,0 / 87 31 / 516 / 18 2 - Carbon dioxide content of the inhalation air when measured at the minimum air flow (paragraph 5.2.13. of the EC Examination Type)

Quit Feeding pressure Air flow C02 contents(%)

numb s

Bar I psig M3Ih I cfm 1

6/ 87 30 / 17 0,85 2

6/87 31 / 18 0,80 3 - Noise level associated with the air supply to the suit when tested at the maximum airflow rate (paragraph 5.2.14 of the EC Examination Tvpe) ult Feeding pressure Airflow Noise level (dB) numb Baripsig M31h; cfm I

1 5,5 / 77 66 / 38 76,8 2

5,5 / 77 65 / 37,8 78,5

Page2/2 4 - Inward leakage average-Fit Factor measured at the minimal air flow of 45011mn (paragraph 2.3.3. of the CE Examination Type)

Suit n0 1

2 Exercise Air flow m3lhl Umn I cfm 30 / 500/ 17 31 / 516 / 18 Standing still 130 000 130 000 Walking (5 kmlh) 59 500 50 000 Moving arms up and down 125 000 125 000 above head Continuous squats 65 000 81 250 Bending forward 100 000 92 850 Person twisting at waist 115 000 130 000 Standing still 130 000 130 000 Average 103 500 103 440 5 - Pressure in the suit when measured at the maximum air flow when suit connected under 5.5 bar (77psig) feeding pressure (paragraph 4.12.of the EC Examination Type)

Suit n 1

2 Exercise P ave/ P min/ Pmax P ave; P min, P Max.

daPa.

daPa Standing still 40 38 Walking (5 kmlh) 40 23 74 100 61 128 Moving arms up and down 40 17 62 46 18 72 above head Continuous squats 42 4

86 56 3

110 Bending forward 52 3

104 74 0

162 Person twisting at waist 38 18 58 46 20 110 Person crawling 37 40 For Information: Both overboots are breaked at the end of the test

6 Over pressure and fit factor when person crawling on the floof as Indicated in paragraph 4.12 and 5.2.2 of the pr EN 1073-1dated 1995 Suit number Crawling exercise Average DP Minimum DP Maximum DP Fit Factor daPa daPa daPa 1

52 12 90 110 000 2

65 3

102 105 000 7

Screen:( paragraph 5.2.5 )

- Distortion of the vision: none

- Mechanical resistance: no incidence on the screen.

NLS2005029 ENCLOSURE 5.5 Page 1 of 2 DONNING AND REMOVAL INSTRUCTIONS FOR MURUROA V4 MTH2

NO/841 442T INDICE: e M.T.H.2 DATE : 12/00 PAGE: 1/1 INSTRUCTIONS FOR USE Preliminary remarks: This clothing is to be used under the authority of the person responsible for issuing the equipment for its dedicated use:

- the clothing offers the necessary protection for it's intended use.

- Breathable air *network hoses with connectors compatible with that of the clothing, are actually available on site and that they are capable of supplying a sufficient quantity of air:

minimum flow rate 600 liters/min. +/- 10% at 6 Bars; (20 cfm at 85 psig) maximum flow rate 1200 liters/min. +/- 10% at 6 Bars; (40cfm at 85 psig)

DRESSING

- The wearer, with a helper, visually inspects the condition of the garment and its components, then removes the shipping protection (cardboard on the visor and inside the garment, and removable "plastic protection" from the visor).

- He enters through the rear opening of the garment and insures that his legs are in the garment.

- Connects to the breathable air network by passing the supply line through the loop at the rear of the garment, at the same height as the supply valve.

- Connects,a communication device, if applicable, through the safety loop and communication loop and finishes dressing.

- The helper zips up the dual zipper system and applies a large strip of adhesive tape to the upper extremity of the second zipper at the top to ensure air tightness. He then, ties the over boot laces around the ankles.

- The wearer can control the air supply by turning the adjustment knob. The correct functioning of the supply flow valve and the over pressure valves can be verified by crouching down rapidly a few times.

- He then is free to enter the work zone.

UNDRESSING

- Undressing may be done in the following manner. While the garment is still being supplied with air, the helper pulls on the orange undressing strip, which runs from one wrist to the other over the hood. Once the undressing strip is removed, the helper can split the suit shell by pulling on the hooded area and separating the suit into two identical pieces. The helper rolls up the front and rear parts in a way that traps the contamination and avoids all contact with the wearer of the garment. (Please consult our video for detailed undressing techniques).

IMPORTANT

- Leave the work zone immediately if the clothing deflates during the work phase evolution.If the helmet fogs, or if the person has a feeling of excessive warmth.

- Remember that the clothing remains pressurised for a few minutes in case of an air supply failure STORAGE In the original packaging; out of the light; between + 5*C and + 450C.( 410F and 1130F)

USAGE The air supply should be between + 150C and + 45°C. ( 590F and 113'F)

EXPIRY DATE The clothing should be used by the third year from the date of manufacture.

CLEANING Not necessary for this type of equipment which is for a single use only.

EMERGENCY FEATURES

- Air outside of the garment can be breathed by removing the safety strip at the front of the helmet/hood.

- The undressing strip, removed by the wearer, enables the wearer to self escape t in less than 5 seconds.

' B. enable aft. sco time EN 152 standat d.