ML031760387

From kanterella
Jump to navigation Jump to search
Summary Report for Inservice Inspections (2R07)
ML031760387
Person / Time
Site: Limerick Constellation icon.png
Issue date: 06/20/2003
From: Levis W
Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
-RFPFR
Download: ML031760387 (234)


Text

ExelonSM Exelon Nuclear Limerick Generating Station www.exeloncorp.com Nuclear P.O. Box 2300 Pottstown, PA 19464 T.S. 4.0.5 & 10CFR50.55a(g)

June 20, 2003 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Limerick Generating Station, Unit 2 Facility Operating License No. NPF-85 NRC Docket No. 50-353

Subject:

LGS Unit 2 Summary Report for Inservice Inspections (2R07)

The LGS Unit 2 Summary Report for Inservice Inspections and ASME Section Xl non destructive examinations, repairs and replacements for the period April 21, 2001 to March 23, 2003 Report No. 7 is submitted in accordance with ASME Section Xl, Article IWA-6200, Unit 2 Technical Specifications Section 4.0.5 and 10CFR50.55a(g).

If you have any questions or require additional information, please do not hesitate to contact us.

Sincerely, William Levis Vice President - LGS

Enclosure:

Limerick Generating Station Unit 2, Summary Report for the April 21, 2001 to March 23, 2003 Periodic Inservice Inspection Report No. 7 cc: H. J. Miller, Administrator, Region I, USNRC A. L. Burritt, LGS USNRC Senior Resident Inspector Ac4l1

bcc: C. Pardee - KSA 3N (wlo attachments)

W. Levis - GML 5-1 (w/o attachments)

J. Benjamin - Cantara w/o attachments)

R. DeGregorio - KSA 3N (wlo attachments)

B. Hanson - GML 5-1 (wlo attachments)

M. Gallagher - KSA 2N (wlo attachments)

D. Helker - KSA 2N (w/o attachments)

K. Kemper - SSB 2-4 w/o attachments C. Mudrick - SSB 3-1 (w/o attachments)

J. Krais - SSB 3-1 (w/o attachments)

E. Kelly - SSB 3-1 (w/o attachments)

H. Do- Cantera (w/o attachments)

D. Schmidt - SSB 3-4 (w/attachments)

M. Karasek - SSB 3-4 (w/attachments)

K. Cellars - KSA (w/o attachments)

R. Dickinson - SSB 2-3 (w/o attachments)

J. Toro - SMB 1-2 (w/attachments)

S. Gamble - SSB 2-4 (w/attachments)

P. Lenair - SSB 3-1 (w/attachments)

J. Grimes - KSA 2N(w/o attachments)

K. Fisher - JSK 4-1 (w/attachments)

J. Kramer - JSK 3-1 (w/attachments)

R. Janati - Commonwealth of PA DEP (w/attachments)

D. Dyckman - (PABRP) SSB 2-4 wlo attachments

LIMERICK GENERATING STATION UNIT 2 SU'VARY REPORT. FOR THE APRIL 21, 2001 TO MARCH 23, 2003 PERIODIC INSERVICE INSPECTION REPORT No. 7

NIS-1 2R07 TABLE OF CONTENTS No. of Pages Form NIS-1 Owner's Report for Inservice Inspections 2 Introduction Examination Period and Requirements 2 Section 1 Summary of Inservice Inspections Conducted 38 During Limerick Generating Station, Unit 2, Cycle 7 Section 2 Summary of Conditions Noted During Cycle 7 3 Inservice Inspection Examination and Tests GE-NE-0000-0006-2250-4a, Structural Evaluation 78 of Core Shroud Welds at Limerick Generation Station, Unit 2 Section 3 Summary of ASME Section Xl Repairs 3 and Replacements Performed During Cycle 7 Form NIS-2 Owner's Report for Repairs and Replacements 101

NIS-1 2R07 Sheet 1 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Exelon Generation Company. LLC. 200 Exelon Way. Kennett Sauare. PA 19348 (Name and Address of Owner)
2. Plant Limerick Generatin Station. P.O. Box 2300. Everareen 8 Sanatoaa Rds. Sanatoga. PA 19464-2300 (Name and Address of Plant)
3. Plant Unit 2 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date January 8. 1990 6. Natonal Board Number for Unit 3960
7. Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Province No. Board No.

Nuclear Reactor Vessel Chicago Bridge 8 Iron Co. B-5027 B116768 3960 Class 1. 2. & 3 Piping Systems _

&Supports

'Traceability per Form N-5 Data Report. Design Specification and Une Number.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8h in. x 11 in.,

(2) information in items through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.

This Form (E00029) may be obtained from the ASME Order Dept, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300

NIS-1 2R07 Sheet 2 of 2 FORM NIS-1 (Back)

8. Examination Dates: Aril 21 2001 to March 23 2003
9. Inspection Period Identification: 2nd 10-Year Inspection In:erval, 1, Period
10. Inspection Interval Identification: January 8. 2000 to January 7. 2010
11. Applicable Edition of Section Xl Reactor Vessel and Class 1 2 and 3 Piping - 1989 Edition Addenda -

Containment - 1992 Edifon Addenda 1992

12. Date/Revision of Inspection Plan: Specification NE-027, Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

See: Section 1. Summary of Inservice Inspections Conducted During Limerick Generating Station. Unit 2, Cyde 7.

14. Abstract of Results of Examination and Tests.

See: Section 2, Summary of Condifions Noted During Cyde 7 Inservice Inspection Examinations and Tests.

15. Abstract of Corrective Measures.

See: Section 3. Summary of ASME Section Xl Repairs and Replacements Performed During Cyde 7.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code. Section Xl. and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certification of Authorization No. (if applicable) NtA Expiration Date NIA Date June 20, 2003 Signed Exelon Generabon Company, LLC By __

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvlvania and employed by HSBCT of Hartford. Connecticut have inspected the components described In this Owners Report during the period April 21. 2001 to March 23. 2003 , and state that to the best of my knowledge and belief, the Owner has performed examinafions and tests and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Secton XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any m or connected with this inspection.

Commissions 7_______________________ PA 2497 I.N.C &A Inspector's Signature National Board, State, Province, and Endorsements nate vs .s 'Zo UJU 2 O5-3

NIS-1 2R07 Introduction Page 1 of 2 Examination Period and Requirements Introduction During the period from April 21, 2001 through March 23, 2003, ASME Section Xl and Augmented Inservice Inspections were performed at Limerick Generating Station Unit 2. The unit was shutdown for a scheduled refueling outage starting March 3, 2003 through March 23, 2003. The inspections performed during this period were credited towards the First Period of the Second Ten-Year Inspection Interval.

Examinations of Class 1, 2 and 3 systems, structures and components (SSC) completed during this period were performed in accordance with the requirements of ASME Section Xl, 1989 Edition. For Class I and 2 piping welds, the alternative requirements of Electric Power Research Institute (EPRI) TR-1 12657, Rev. B-A,

'Revised Risk Informed Inservice Inspection Evaluation Procedure," were used for component selection and examination methodology along with the evaluation and sample expansion requirements identified in ASME Code Case N-578-1, "Risk Informed Requirements for Class 1, 2, and 3 Piping, Method B." The examinations of Class MC and CC Containment SSC were performed in accordance with the requirements of ASME Section Xl, 1992 Edition with the 1992 Addenda. Refer to the LGS Unit 2 ISI Program, Specification NE-027, Revision 2, for detailed requirements.

Augmented Inservice Inspections were performed in accordance with the following guidance. Refer to the LGS Unit 2 ISI Program, Specification NE-027, Revision 2, for detailed requirements.

AUG-01 USNRC Generic Letter 88-01, ntergranular Stress Corrosion Cracking AUG-02 NUREG-0619, BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking AUG-03 IE Bulletin No. 80-13, Cracking in Core Spray Spargers, and BWRVIP-18, BWR Core Spray Internals AUG-04 NUREG/CR-3052, Closeout of IE Bulletin 80-07, BWR Jet Pump Assembly Failure, and BWRVIP-41, BWR Jet Pump Assembly AUG-05 USNRC Mechanical Engineering Branch (MEB) Technical Position MEB 3-1, NUREG-0800, No Break Boundaries AUG-07 SIL No. 455, Recommendation for Additional ISI of Alloy 182 Nozzle Weldments AUG-09 Examination of the RPV Closure Head Lifting Lugs AUG-10 UFSAR Table 3.2-1, Non-Q Reactor Pressure Vessel Internal Components AUG-13 Technical Specification 3/4.7.4, Snubber Examination and Testing Program AUG-15 SIL No. 433, Shroud Head Bolt Cracks

NIS-1 2R07 Introduction Page 2 of 2 Examination Period and Requirements AUG-16 SIL No. 462, Shroud Support Access Hole Cover Cracks AUG-17 SIL No. 474, Steam Dryer Drain Channel Cracking AUG-22 USNRC IEB Nos. 95-02 and 96-03, RHR and CS Suction Strainers AUG-26 BWRVIP-42, BWR LPCI Coupling AUG-27 BWRVIP47, BWR Lower Plenum AUG-28 BWRVIP-48, BWR Reactor Pressure Vessel IDAttachment Welds AUG-30 BWRVIP-05, BWR Reactor Pressure Vessel Shell Welds

NIS-1 2R07 Section 1 Summary of Inservice Inspections Conducted During Limerick Generating Station, Unit 2, Cycle 7 April 21, 2001 to March 23, 2003

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Outage: 2R07 Shell Ring No. 1 Vertical 3/812003 B1.12 AUG Seam Weld STD. No. IA L12JBB XI-RPV-2 B-A Xi UT 100% RI 701500 GE-UT-704V5 Shell Ring No. 1 Vertical 318/2003 81.12 AUG 6 Recordable ind. Acceptable to IWB-Seam Weld 3510-1.

STD. No. IA L12JBC XI-RPV-2 B-A Xi UT 100% RI 701700 GE-UT-704V5 Shell Ring No. 1 Vertical 34812003 61.12 AUG 1 Recordableind. AcceptabletolWB-Seam Weld 3510-1 STD. No. IA Li2/BD XI-RPV-2 B-A Xl UT 100% RI 701900 GE-UT-704V5 Shel Ring No. 2 Vertical 3/812003 B1.12 AUG 2 Recordable ind. Acceptable to IWB-Seam Weld 3510-1.

STD. No. IA 12/AH XI-RPV-2 B-A Xi UT 100% NRI 714600 GE-UT-300V6 Closure Head Dollar 3/8/2003 B1.21 Examined from 0 Deg to 120 Deg.

Plate Weld STD. No. 3 L12/DB XI-RPV-2 B-A xl UT 91% RI 713800 GE-UT-300V6 and GE-UT-304V3 Bottom Head Weld 311412003 B1.22 2 Recordable Id. Acceptable to IWB 3510-1. Limited by Support Skirt Knuckle.

STD. No. 1A Li21DC XI-RPV-2 B-A Xl UT 91% RI 713900 GE-UT-300V6 and GE-UT-304V3 Bottom Head Weld 3/14/2003 B1.22 1 Recordable ind. Acceptable to IWB-3510-1. Limited by Support Skirt Knuckle.

STD. No. IA L12/DH XI-RPV-2 B-A Xl UT 100% RI 714800 GE-UT-300V6 and GE-UT-304V3 Closure Head Weld 3110/2003 B1.22 2 Recordable hd. Acceptable to IWB-3510-1. Supplemental MT, NRI.

STD. No. 3 Li21DJ XI-RPV-2 B-A Xl UT 100% RI 714900 GE-UT-300V6 and GE-UT-304V3 Closure Head Weld 3/11/2003 B1.22 18 Recordable ind. Acceptable to IWB-3510-1. Fabricaton Flaws.

STD. No. 3 L121AF XI-RPV-2 B-A Xl UT 100% NRI 701100 GE-UT-306V0 Shell Ring No. 5 to 3/412003 B1.30 Examined from sealing surface only Flange Weld from 0 Deg to 360 Deg.

STD. No. 2 ue1,20 85

_~ ~~Pg 1 at2_ody Page of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Outage: 2R07 Procedure(s)

Inspection Comments Cal Block Li21AG XI-RPV-2 B-A MT 88% NRI 714500 GE-UT-306V0 and GE-MT-100V3 Closure Head to Flange 3/9/2003 B1.40 UT 88% NRI Examined from 0 Deg to 120 Deg.

Weld Limited due to configuration.

STD. No. 3 Li2/Nt7C-IR XI-RPV-2 B-D Xi UT 100% NRI 712400 GE-UT-705V2 LPCI "A" Loop Nozzle 3/12/2003 B3.100 Zi and Z2A Inside Radius Section LIM-2 Li2/NIB-IR XI-RPV-2 B-D Xi UT 100% NRI 704300 GE-UT-705V2 Recirculation Outlet "8" 3/9/2003 B3.100 Zl and Z2A Loop Nozzle inside Radius Section STD. No. 1A Li2/N2B-IR XI-RPV-2 B-D Xl UT 100% NRI 704900 GE-UT-705V2 Recirculation Inlet "B 311212003 B3.100 ZI and Z2A Loop Nozzle Inside Radius Section STD. No. 1A Li2/N2C-IR XI-RPV-2 B-D Xl UT 100% NRI 705200 GE-UT-705V2 Recirculation Inlet "B" 3/11/2003 B3.100 Zl and Z2A Loop Nozzle Inside Radius Section STD. No. 1A Li2/N2E-IR XI-RPV-2 B-D Xi UT 100% NRI 705800 GE-UT-705V2 Recirculabon Inlet "B" 3/11/2003 B3.100 Zl and Z2A Loop Nozzle Inside Radius Secton STD. No. 1A Li2/N2F-IR XI-RPV-2 B-D Xl UT 100% NRI 706100 GE-UT-705V2 Recirculation Inlet "B" 3/10/2003 B3.100 Zl and Z2A Loop Nozzle Inside Radius Section STD. No. 1A Li2/N2G-IR XI-RPV-2 B-D Xl UT 100% NRI 706400 GE-UT-705V2 Recirculabon Inlet "B" 3/11/2003 63.100 Zl and Z2A Loop Nozzle Inside Radius Section STD. No. 1A Li2/N3A-IR XI-RPV-2 B-D Xl UT 100% NRI 707600 GE-UT-705V2 Main Steam "A" Loop 3/6/2003 B3.100 Zl and Z2A Nozzle Inside Radius Section STD. No. IA Page 2 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Outage: 2R07 Main Steam *B- Loop 3/712003 B3.100 Zi and Z2A Nozzle Inside Radius Section STD. No. A Li2IN4C-IR XI-RPV-2 B-D Xi UT 100% NRI 709400 GE-UT-705V2 Feedwater C" Loop 3/7/2003 B3.100 AUG Zl, Z2A. Z2B, and Z3 Nozzle Inside Radius Section STD. No. A Li2IN4D-IR XI-RPV-2 B-D Xl UT 88% NRI 709700 GE-UT-705V2 Feedwater D Loop 3/9/2003 83.100 AUG Zi, Z2A, Z2E, and Z3 Restricted scans Nozzle Inside Radius due to Ni1 Nozzle pad and TC Pads Section STD. No. A Li2/N17C XI-RPV-2 B-D Xl UT 77% NRI 712300 GE-UT-705V2 LPCI A Loop Nozzle to 312/2003 83.90 Vessel Weld STD. No. IA L12JNIB XI-RPV-2 B-D Xl UT 71% RI 704200 GE-UT-705V2 Recirculaton Outlet B- 311012003 B3.90 6 recordable indications, Near Surface.

Loop Nozzle to Vessel Acceptable to IWB-3512-1 Weld STD. No. IA LI2IN2B XI-RPV-2 B-D Xi UT 77% NRI 704800 GE-UT-705V2 Recirculation Inlet B 3/12/2003 83.90 Loop Nozzle to Vessel Weld STD. No. 1A Li2/N2C XI-RPV-2 B-D Xl UT 77% RI 705100 GE-UT-705V2 Recirculation Inlet B- 3/11/2003 B3.90 2 recordable indications. Acceptable to Loop Nozzle to Vessel IWB-3512-1 Weld STD. No. IA LI2/N2E XI-RPV-2 B-D Xi UT 77% NRI 705700 GE-UT-705V2 Recirculation Inlet "B. 3/11/2003 B3.90 Loop Nozzle to Vessel Weld STD. No. 1A Li2JN2F XI-RPV-2 B-D Xl UT 77% NRI 706000 GE-UT-705V2 Recirculation Inlet 'A' 3110/2003 83.90 Loop Nozzle to Vessel Weld STD. No. 1A 85 ody ue1,20

-~ ~ ~ ~ Pg f2 Page 3 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Recirculation Inlet 'A' 3/11/2003 B3.90 Loop Nozzle to Vessel Weld STD. No. IA i

1.2IN3A XI-RPV-2 B-D Xi UT 77% NRI 707500 GE-UT-705V2 I /ain Steam A Loop 316/2003 B3.90 1 ozzle to Vessel Weld STD. No. A l121N3B XI-RPV-2 B-D Xl UT 77% RI 707800 GE-UT-705V2 Main Steam 'B Loop 317/2003 B3.90 1 recordable indiation, Near Surface.

Nozzle to Vessel Weld Acceptable to IWB-3512-1 STD. No. IA 121N4C XI-RPV-2 B-D Xl UT 77% NRI 709300 GE-UT-705V2 eedwater-C- Loop 3/10/2003 B3.90 tJozzle to Vessel Weld l I~~~~~~~~~~~~~~~~~~~~~oI ~~~~~~~~~~~~~~~~~~~~~~~~STD.

No. 1A Ll2IN4D XI-RPV-2 B-D Xl UT 66% RI 709600 GE-UT-705V2 Feedwater p" Loop 3/8/2003 B3.90 2 recordable indications. Acceptable to Nozzle to Vessel Weld IWB-3512-1 STD. No. 1A LI2/RPV CLOSURE XI-RPV-2 B-G-1 Xl UT 100% NRI 724300 GE-UT-317V1 HEAD NUTS Nuts SN I - SN 76 3/712003 B6.10 Examined #1 -#26 8.5-6-8-CS-22PEB LI2/RPV,CLOSURE XI-RPV-2 B-G-1 Xl UT 100% NRI 724400 GE-PDI-UT-5R2 STUDS IN PLACE

¶tuds SN I - SN 76 3/4/2003 B6.20 #1 -#17 and #22 - #26 CLOSURE STUD IJ21THREADED HOLES XI-RPV-2 B-G-1 Xl UT 98% NRI 724600 GE-UT-308V2 IN RPV FLANGE Holes SNI - SN 76 3/4/2003 86.40 #1 -#26 STD. No. 2 I172JRPV CLOSURE XI-RPV-2 B-G-1 Xl VT-1 100% NRI 724700 ER-AA-335-016R1 WASHERS Washers SN 1 - SN 76 3/7/2003 B6.50 Examined #1 - #17 and #22 - 30.

I-_

Page 4 of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 L12INCORE HOUSING XI-BN-5 B-G-2 FLANGE BOLTING 55 InCore Housing 3/112003 B7.10 Examined by Exelon 27 core locations Flanges 4/FNG were examined: 56-41, 56-33, 56-25, 56-17. 48-53, 48-49, 48-41, 48-33, 48-25, 48-17, 48-13, 48-09, 40-57, 40-49, 40-45, 40-41, 40-33, 40-25. 40-21, 40-17, 40-09, 32-33. 32-29, 32-25, 32-17, and 32-09.

41-2FOtOB (BOLTING) XI-DLA-206-1 B-G-2 Xi VT-i 100% NRI 104400 ER-AA-335-017R2 24" Check Valve Hinge 3/112003 B7.70 Examined by Exelon Pin Cover Bolting HV-52-2FO06A XI-DLA-21 1-1 B-C-2 Xi VT-1 100% NRI 027500 ER-AA-335-017R2 (BOLTING) 12' Check Valve Bonnet 3110/2003 B7.70 Examined by Exelon and Bearing Cover Bolting Li21CRD HOUSING XI-BN-6 B-G-2 Xi VT-I 100% NRI 739700 ER-AA-335-014R1 FLANGE BOLTING 185 CRD Housing 311512003 B7.80 Examined by Exelon 19 core locations:

Flanges- 8 Cap Screws 06-35. 14-43, 18-35, 22-11, 22-15, 22-per Flange 51, 26-07, 30-59. 34-03, 34-07, 34-11.

38-23, 38-59, 42-19. 42-51, 46-27. 46-51, 50-47. and 58-35.

41-2F010B (INT. SURF.) X-DLA-206-1 B-M-2 Xi VT-3 100% NRI 104600 ER-AA-335-017R2 24" Check Valve Internal 311112003 B12.50 Examined by Exelon Surfaces HV-52-2F006A (INT. Xl-DLA-211-1 B-M-2 Xl VT-3 100% NRI 027600 ER-AA-335-017R2 SURF.)

12' Check Valve Internal 3/1012003 B12.50 Examined by Exelon Surfaces ST-4-041-950-2 ST-INDEX B-P Xl Vr-2 100% NRI ISI System Leakage 3/18/2003 B15.10 Test for all Class 1 Systems and some Class 2 Systems 2AE-205 SG-1 XI-2E-205 C-A Xl UT 100% NRI 365900 GE-PDI-UT-1R3 Shell (Ring #1) to 316/2003 C1.10 Flange Weld LIM-F-1 .18-CS 2AE-205 SG-3 XI-2E-205 C-A Xl UT 100% NRI 361900 GE-PDI-UT-1R3 Shell Weld (Ring #3) to 3/6/2003 C1.10 Shell Weld (Ring #2)

LIM-F-.812-CS & LIM-F-1.18-CS Page 5 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Outage: 2R07 Component ID Iso Number Sect. XI Inspection Actual Code Results Summary Procedure(s)

Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block 2AE-205 N-4-1 Xl-2E-205 C-B Xl MT 100% NRI 366300 GE-PDI-UT-1R3 and GE-MT-1 00V3 Outlet Nozzle (N-4) to 3/6/2003 C2.21 UT 100% NRI Shell Weld (Ring #1)

LIM-F-1.18-CS 2AE-205 N4-1 INNER XI-2E-205 C-B Xl UT 100% NRI 366500 GE-UT-311V7 RADIUS Outlet Nozzle (N-4) 3/6/2003 C2.22 Inner Radius LIM-F-1.18-CS 2BP-202 SWC-1 16 XI-2P-202 C-G Xi MT 100% NRI 367300 GE-MT-100 V3 Discharge Elbow to 3!13/2003 C6.10 Flange Weld 2BP-202 SWC-2 16 XI-2P-202 C-G Xi MT 100% NRI 367100 GE-MT-100 V3 Discharge Elbow to 3/13/2003 C6.10 Head Flange Weld 2BP-202 SWN-1 16 XI-2P-202 C-G Xi MT 100% NRI 367200 GE-MT-100 V3 Discharge Elbow to 3/13/2003 C6.10 Stuffing Box Weld 2BP-202 SWN-2 16 XI-2P-202 C-G Xl MT 100% NRI 367400 GE-MT-100 V3 Stuffing Box Attachment 3/13/2003 C6.10 Weld ST-4-001 -950-2 ST-INDEX C-H Xl VT-2 100% NRI ISI Inservice Pressure 2/8/2002 C7.30 Test of the Main Steam System ST-4-026-950-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Inservice Pressure 6/25/2002 C7.30 Test of Plant Process Radiation Monitorng Piping ST-4-030-950-2 ST-INDEX C-H Xi VT-2 100% NRI Pass and Containment 3/16/2003 C7.30 Atmospheric Control Sample Loops Functional Pressure Test and Contaminated Piping Inspection ST-4-047-952-2 ST-INDEX C-H Xl VT-2 100% NRI ISi Pressure Test of 11/21/2002 C7.30 East Bank of CRD HCU'S Page 6 of 20 Monday, June 16, 2003 18:56

I I Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 Component ID Description ST-4 047-953-2 ISI Pressure Test of 11121/2002 C7.30 West Bank of CRD HCU S ST-4-048-950-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Functional Pressure 7/1912001 C7.30 Test of Standby Liquid Control Discharge Piping to Squib Valves ST-048-952-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Inservice Pressure 7/1512002 C7.30 Test of Standbv Liquid Control Suction Piping ST-4-049-953-2 ST-INDEX C-H Xl VT-2 100% NRI ISI Inservice Pressure 7/10/2002 C7.30 Test of RCIC Exhaust Vacuum Breaker Piping ST-4-051-951-2 ST-INDEX C-H Xl VT-2 100% NRI ISI Functional Pressure 7/27/2001 C7.30 Test of RHR Loop A ST-051-952-2 ST-INDEX C-H Xl VT-2 100% NRI ISI Functional Pressure 5/29/2002 C7.30 Test of RHR Loop B ST-4-O51-953-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Functional Pressure 10112/2001 C7.30 Test of RHR Loop C ST-4-051-954-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Functional Pressure 8/1512002 C7.30 Test of RF1R Loop D ST-4-052-953-2 ST-INDEX C-H Xi VT-2 100% NRI ISI Functional Pressure 7/19/2001 C7.30 Test of Safeguard Piping Fill Loops A and B ST-4-055-951-2 ST-INDEX C-H Xl VT-2 100% NRI ISI Inservice Pressure 12/19/2001 C7.30 Test of HPCI Pump and Turbine Supply ST-055-954-2 ST-INDEX C-H Xl VT-2 100% -NRI ISI Inservice Pressure 9/18/2002 C7.30 Test of HPCI Exhaust Vacuum Brealer Piping Page 7 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 Outage: 2R07

[SI Inservice Pressure 6/21/2001 C7.30 Test of Class 2 Drywell Chilled Water System Components ST-4-057-952-2 ST-INDEX C-H, Xl VT-2 100% NRI D-A B Post LOCA 3/15/2003 C7.30, Recombiner Pneumatic D1.10 Pressure Test and Contaminated Piping Inspecbon ST-4-057-951-2 ST-INDEX C-H. Xi VT-2 100% NR!

D-A A Post LOCA 3/11/2003 C7.30, Recombiner Pneumatic D1.10 Pressure Test and Contaminated Piping Inspection ST-4-020-951-2 ST-INDEX D-A Xi VT-2 100% NRI ISI Functional Pressure 8/22/2001 D1.10 Test of D21 Diesel Fuel Oil Transfer System ST-4-020-952-2 ST-INDEX D-A Xl VT-2 100% NRI ISI Functional Pressure 11/28/2001 D1.10 Test of D22 Diesel Fuel Oil Transfer System ST-4-020-953-2 ST-INDEX D-A Xl VT-2 100% NRI ISI Functional Pressure 8/8/2001 D1.10 Test of D23 Diesel Fuel Oil Transfer System ST-4-020-954-2 ST-INDEX D-A Xi VT-2 100% NRI ISI Functional Pressure 11/13/2001 D1.10 Test of D24 Diesel Fuel Oil Transfer System ST-4-020-961-2 ST-INDEX D-A Xi VT-2 100% NRI D21 Diesel Fuel Oil 8/23/2001 D1.10 Storage and Transfer System Buried Pipe and Storage Tank 2A-T527 Pressure Decay Test Page 8 of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 D22 Diesel Fuel Oil 8/26/2002 D1.10 Storage and Transfer System Buried Pipe and Storage Tank 2BT527 Pressure Decay Test ST4-020-963-2 ST-INDEX D-A Xl VT-2 100% NRI D23 Diesel Fuel Oil 7/1012001 D1.10 Storage and Transfer System Buried Pipe and Storage Tank 2C-T527 Pressure Decay Test ST-4-020-964-2 ST-INDEX D-A XI v -2 1G^% NRI D24 Diesel Fuel Oil 2/11/2002 D1.10 Storage and Transfer System Buried Pipe and Storage Tank 2DT527 Pressure Decay Test ST4-092-961-2 ST-INDEX D-A Xl Vr-2 100% NRI ISI Pressure Test of the 6/2612002 D1.10 D21 Diesel (2AG501)

Fuel and Diesel Oil Storage and Transfer Systems ST-4-092-962-2 ST-INDEX D-A Xl VT-2 100% NRI ISI Pressure Test of the 5/29/2001 D1.10 D22 Diesel (2BG501)

Fuel and Diesel Oil Storage and Transfer Systems ST-4-092-963-2 ST-INDEX D-A Xl Vr-2 100% NRI ISi Pressure Test of the 7/10/2002 D1.10 D23 Diesel (2CG501)

Fuel and Diesel Oil Storage and Transfer Systems APE-2MS HHAI XI-APE-2MS-LA F-A Xl VT-3 100% RI 176900 ER-AA-335-016R1 and MAG-CG407 Variable Support 3/5/2003 F1.10 Loose nuts evaluated on NCR LG 93-00060 as acceptable. CR 00147692 DCA-205-H007 XI-DCA-205-1 F-A Xl Vr-3 100% NRI 332900 ER-AA-335-016R1 and MAG-CG-407 Mechanical Snubber 3/5/2003 F1.10 AUG DCA-205-HOOB XI-DCA-205-3 F-A Xl VT-3 100% NRI 336700 ER-AA-335-016R1 and MAG-CG-407 Mechanical Snubber 3/1012003 F1.10 AUG Page 9 of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I I 11"I '3

%J1111L I& ~~~~~~~~Outage: 2R07 Component ID iso Number Sect. XI Inspection Actual Code Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block DCA-212-EI HI XI-DCA-212-E1 F-A xi VT-3 100% NRI 691800 ER-AA-335-016Rl and MAG-CG-407 Rigid Support 3/5/2003 Fib1 DCA-212-EI H2 XI-DCA-212-El F-A xi VT-3 1000/ NRI 691700 ER-AA-335-016Rl and MAG-CG-407 Rigid Support 3/5/2003 F1i1 DCA-212-El H3 XI-DCA-212-El F-A xi VT-3 100% NRI 691600 ER-AA-335-01 6Rl and MAG-CG-407 Rigid Support 3/5/2003 F1.10 DCA-213 H5 XI-DCA-213-1 F-A xi VT-3 1000/ NRI 586500 ER-AA-335-016Rl and MAG-CG-407 Rigid Support 3/5/2003 F1.10 DCA-213 H6 Xl-DCA-213- F-A xi VT-3 100% NRI 586600 ER-AA-335-01 6Rl and MAG-CG-407 Rigid Support 3/5/2003 F1i1 DCA-420-H002 XI-DCA-420-1 F-A xi VT-3 100% NRI 025200 ER-AA-335-016Rl and MAG-CG-407 Mechanical Snubber 3/7/2003 F1.10 AUG DCA-420-H003 XI-DCA-420-1 F-A xi VT-3 1000/ NRI 025000 ER-AA-335-016SRl and MAG-CG-407 Mechanical Snubber 3/7/2003 F1.10 AUG DLA-205-1 FW2 xi-DLA-205-1 F-A xi VT-3 100% NRI 103800 ER-AA-335-016Rl and MAG-CG-407 Anchor: Flued Head X- 3/14/2003 F1.10 9A to Penetration Sleeve DLA-207-H003 XI-DLA-207-1 F-A x il` - 1000/ NRI 111600 ER-AA-335-016Rl and MAG-CG-407 Variable Support 3/5/2003 F1.1 DI-A-207-1-004 XI-DLA-207-1 F-A xilr- 1000/ NRI 112200 ER-AA-335-016Rl and MAG-CG-407 Variable Support 3/5/2003 F1.10 DLA-208-H003 XI-DLA-208-1 F-A xi Vr-3 1000/ RI 118700 ER-AA-335-016Rl and MAG-CG-407 Variable Support 3/5/2003 F1.10 4" nail lodged in spring. Removed and re-examined by Exelon, NRI DLA-208-HOO' 4 XI-DLA-208-1 F-A xi VT-3 100% NRI 119300 ER-AA-335-01 6Rl and MAG-CG-407 Variable Suppiort 3/512003 F1.10 VRR-2RS HBI I xl-VRR-2RS-2B F-A xi VT-3 1000/ RI 656300 ER-AA-335-016Rl and MAG-CG-407 Rigid Support 3/8/2003 F1.10 Gap between nuts and clamp.

Acceptable per P-319 EBB-203 HIlI XI-EBB-203-1 F-A xi V/T-3 100% NRI 222300 ER-AA-335-016R1 and MAG-CG-407 Rigid Support 3/7/2003 F1.20 EBB-203 H12 )(i-FBB-203-1 F-A xi VT-3 1000/ NRI 222400 ER-AA-335-016R1 and MAG-CG-407 Rigid Support 3/7/2003 Fl1.20 Page 10 of 20 ~~~Monday, Page 10of20 June 16, 2003 18:56 11111111111111L

Interval: 2 Limerick ISI Component Inspection Results Listing Period: 1 Unit 2 Outage: 2R07 Component ID Iso Number Sect. Xl Inspection Actual Code Results Summary Procedure(s)

Description Insp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block EBB-203 H14 XI-EBB-203-1 F-A Xi VT-3 100% NRI 222600 ER-A-335-016R1 and MACCG-407 Rigid Support 3/712003 F1.20 EBB-207 H6 XI-EBB-207-2 F-A Xl Vr-3 100% NRI 239200 ER-AA-335-016R1 and MAG-CG-407 Variable Support 3/412003 F1.20 EBB-242 H13 XI-EBB-242-lES F-A Xl VT-3 100% NRI 008500 ER-AA-335-016Rl and MAG-CG-407 Rigid Support 3/912003 F1.20 EBB-242 H20 XI-EBB-242-IWS F-A Xl Vr-3 100% NRI 013700 ER-AA-335-016R1 and MAG-CG-407 Rigid Support 3/612003 F1.20 EBB-242 1122 XI-EBB-242-IWS F-A Xl Vr-3 100% NRi 012900 ER-AA-335-016R1 and MA%G-CG-407 Rigid Support 316/2003 F1.20 EB8-242-IES M-2411 XI-EBB-242-IES F-A Xi VT-3 100% NRI 008900 ER-AA-335-016R and MAG-CG-407 Rigid Support 3/612003 F1.20 EBB-242-1WS M-2413 XI-EBB-242-1WS F-A Xi Vr-3 100% NRI 014000 ER-AA-335-016R1 and MAG-CG-407 Rigid Support 316/2003 F1 .20 GBB-201 H2 XI-GBB3-201-1 F-A Xl Vr-3 100% NRI 382400 MAG-CG-407R7 Rigid Support 81221002 F1.20 Examined by Exelon GBB-201 4 XI-GBB-201-1 F-A Xl Vr-3 100% NRI 382800 MAG-CG-407R7 Rigid Support 812212002 F1.20 Examined by Exelon GBB-201 H5 XI-GBB-201-1 F-A Xl Vr-3 100% NRI 382900 MAG-CG-407R7 Rigid Support 8/22/2002 F1.20 Examined by Exelon GBB-217 Hi XI-GBB-217-1 F-A Xi VT-3 100% NRI 428300 MAG-CG-407R7 Rigid Support 8/2212002 F1.20 Examined by Exelon GBB-217 H2 XI-GBB-217-1 F-A Xl VT-3 100% NRI 428200 MAG-CG-407R7 Rigid Support 8/22/2002 F1.20 Examined by Exelon GBB-218 H901 XI-GBB-218-2 F-A Xl VT-3 100% NRI 439800 MAG-CG-407R7 Anchor 8/2912002 F1.20 Examined by Exelon GBB-218-H066(A) XI-GBB-218-1 F-A Xl VT-3 100% NRI 435800 ER-AA-335-016R1 and MAG-CG-407 Mechanical Snubber 3/312003 F1.20 AUG Pin out only GBB-218-H066(B) XI-GBB-218-1 F-A Xl Vr-3 100% NRI 436500 ER-AA-335-016R1 and MAG-CG-407 Mechanical Snubber 3/3/2003 F1.20 AUG Pin out only GBB-219 H4 XI-GBB-219-2 F-A Xl VT-3 100% NRI 461800 ER-AA-335-016R1 and MAG-CG-407 Variable Support 3/312003 F1.20 Page 11 of 20 Monday. June 16 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: 1 Unit 2 Outage: 2R07 XI-HBB-210-1 F-A MAG-CG-407R7 Rigid Support 8/21/2002 F1.20 Examined by Exelon HBB-210 H2 XI-HBB-210-1 F-A Xi VT-3 100% NRI 170500 MAG-CG-407R7 Rigid Support 8/21/2002 F1.20 Examined by Exelon HBB-217 H5 XI-HBB-217-4 F-A Xi VT-3 100% NRI 494000 MAG-CG-407R7 Rigid Support 8/22/2002 F1.20 Examined by Exelon HBB-217 H6 XI-HBB-217-4 F-A Xi VT-3 100% NRI 494100 MAG-CG-407R7 Rigid Support 8/22/2002 F1.20 Examined by Exelon HBB-220 H23 XI-HBB-220-4 F-A Xi VT-3 100% NRI C720^^ M7-CG-40'R7 Rigid Support 8/26/2002 F1.20 Examined by Exelon HBB-220 H24 XI-HBB-220-4 F-A Xl VT-3 100% NRI 072100 MAG-CG-407R7 Rigid Support 8/26/2002 F1.20 Examined by Exelon GBC-201-H082 GBC-201-2 F-A Xl VT-3 100% NRI 254300 ER-AA-335-016R1 Mechanical Snubber 3/7/2003 F1.30 AUG Pin out only GBC-201-H189(A) GBC-201-4 F-A Xl VT-3 100% NRI 259000 ER-AA-335-016R1 Mechanical Snubber 3/8/2003 F1.30 AUG Pin out only GBC-201-H189(B) GBC-201-4 F-A Xi VT-3 100% NRI 259300 ER-AA-335-016R1 Mechanical Snubber 3/8/2003 F1.30 AUG Pin out only GBC-216 Hl GBC-216-11 F-A Xi VT-3 50% NRI 273100 ER-AA-335-016R1 Rigid Support 3/10/2003 F1.30 Top only. Not accessible to Under Water camera.

GBC-216 H2 GBC-216-10 F-A Xl VT-3 50% NRI 272400 ER-AA-335-016R1 Rigid Support 3/10/2003 F1.30 Top only. Not accessible to Under Water camera.

GBC-216 H4 GBC-216-6 F-A Xl VT-3 50% NRI 278600 ER-AA-335-016R1 Rigid Support 3/10/2003 F1.30 Top only. Not accessible to Under Water camera.

HBC-282 H901 HBC-282-2 F-A Xl VT-3 100% NRI 532100 MAG-CG-407R7 Anchor 8/29/2002 F1.30 Examined by Exelon 20P-204 FC-1 XI-20P-204 F-A Xl VT-3 100% NRI 131500 MAG-CG-407R7 Final Mech Conn. Base 8/21/2002 F1.40 Examined by Exelon Plate Embed 1 1/4" Bolting to Building (Typical of 8)

Page 12 of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 20P-204 IC-1 XI-20P-20 Intermediate Mrch Conn. 8121/2002 F1.40 Examined by Exelon Main Pump to Support Arm 1 1/2' Bolfing (Typical of 4) 20P-204 IC-2 XI-20P-204 F-A Xi VT-3 100% NRI 131100 MAG-CG-407R7 Intermediate Welded 8/21/2002 F1.40 Examined by Exelon Conn. Main Pump Support Arm to Base Plate (Typical of 4) 20P-204 IC-3 XI-20P-204 F-A Xl VT-3 100% NRI 131200 MAG-CG-407R7 Intermediate Mech &21,2002 F1.40 Examined by Exelon Conn. Booster Pump to Support Arm 1 3/8 Bolting (Typical of 4) 20P-204 IC-4 XI-20P-204 F-A Xl VT-3 100% NRI 131400 MAG-CG-407R7 Intermediate Welded 8/21/2002 F1.40 Examined by Exelon Conn. Booster Pump Support Arm to Base Plate (Typical of 4) 20P-204 IM-1 XI-20P-204 F-A Xl Vr-3 100% NRI 131000 MAG-CG-407R7 Main Pump Support Arm 8/21t2002 F1.40 Examined by Exelon (Typical of 4) 20P-204 I-2 XI-20P-204 F-A Xl VT-3 100% NRI 131300 MAG-CG-407R7 Booster Pump Support 8/21/2002 F1.40 Examined by Exelon arm (Typical of 4)

Li21RPV STABILIZER XI-FA-2 F-A Xl VT-3 100% NRI 757200 ER-AA-335-016R1 (0 DEG)

Stabilizer Assembly 3t5/2003 F1.40 Brackets L121RPV STABILIZER XI-FA-2 F-A Xl VT-3 100% NRI 757500 ER-AA-335-016R1 (135 DEG)

Stabiizer Assembly S 315/2003 F1.40 Brackets L121RPV STABILIZER XI-FA-2 F-A Xl VT-3 100% NRI 757300 ER-AA-335-016R1 (45 DEG)

Stabilizer Assembly & 3t5/2003 F1.40 Brackets Li2IRPV SUPPORT XI-FA-1 F-A Xl VT-3 100% RI 758000 ER-AA-335-016R1 Support Skirt Assembly 3/11/2003 F1.40 Examined from 0 Deg to 180 Deg.

Loose bolfing evaluated as acceptable during PSI. See Bechtel NCR 12886 Page 13 of 20 Monday. June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 Outage: 2R07 Pump Suction Strainer 3/10/2003 N/A No signs of strainer clogging Module 2A1F214 Xl-HBB-220-1A N/A AUG VT-3 50% NRI 540010 MAG-CG-425R4 Pump Suction Strainer 3/10/2003 N/A No signs of strainer clogging Module 2A2F211 Xl-HBB-217-1A N/A AUG VT-3 50% NRI 540110 MAG-CG-425R4 Pump Suction Strainer 3/10/2003 N/A No signs of strainer clogging Module 2B1F211 XI-HBB-217-2A NiA AUG VT-3 50% NRI 540130 MAG-CG-425R4 Pump Suction Strainer 3/10/2003 N:A No signs of strainer clogging Module 2BtF214 XI-HBB-220-2A N/A AUG VT-3 50% NRI 540050 MAG-CG-425R4 Pump Suction Strainer 3/10/2003 N/A No signs of strainer clogging Module 2B2F211 XI-HBB-217-2A N/A AUG VT-3 50% NRI 540140 MAG-CG-425R4 Pump Suction Strainer 3/10/2003 N/A No signs of strainer clogging Module APE-2MS-LA-37 SWA XI-APE-2MS-LA N/A AUG UT 100% NRI 176400 GE-PDI-UT-1R3 26" Pipe to Elbow 3/12/2003 N/A LIM-26-1.013-CS APE-2MS-LB-36 SWA XI-APE-2MS-LB N/A AUG UT 100% NRI 180900 GE-PDI-UT-1R3 26" Pipe to Elbow 3/12/2003 N/A LIM-26-1.013-CS DBA-207-1 FWII Xl-DBA-207-1 N/A AUG UT 100% NRI 288500 GE-PDI-UT-1R3 and GE-PDI-UT-2R3 4" Pipe to FE-2N016 3/12/2003 N/A Best effort. Examine when qualified (Bimetallic) DM procedure is available. No ANII involvement.

LIM-4-.337-CS & LIM-4-.337-SS304 DBA-207-1 FW52 XI-DBA-207-1 N/A AUG UT 100% NRI 288900 GE-PDI-UT-1R3 3" Elbow to Pipe 3/13/2003 N/A No ANII involvement.

LIM-3-.438-CS DBA-207-1 FW53 XI-DBA-207-1 N/A AUG UT 100% NRI 289100 GE-PDI-UT-1R3 3" Pipe to Valve HV 3/13/2003 N/A No ANII involvement.

2F007 LIM-3-.438-CS Page 14 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 DBB-204-1 FW3 XI-DBB-204-1 N/A AUG UT 100% RI 123600 GE-PDI-UT-1R3 16" Pipe to Valve HV 3/10/2003 N/A 1 recordable ind. Root Geometry 209B LIM-16-1.219-CS DCC-203-1 FW21 XI-DCB-202-1 N/A AUG UT 100% NRI 684100 GE-PDI-UT-2R3 6" Pipe to Pipe 3/11/2003 N/A CB 0.55in. DS of weld centerline.

LIM-06-.432-SS316 L12/CS STRAINER XI-HBB-220-IA N/A AUG VT-3 100% NRI 540220 MAG-CG-425R4 MODULE Pump Suction Strainer 3/10/2003 N/A Performed in conjunction with suction Module strainer exams. No measurable sludge build-up in this area.

Li2/LIFTING LUG 000 XI-BH-4 N/A AUG MT 100% NRI 725800 GE-MT-100V3 DEG Lug to Closure Head 3/7/2003 N/A Weld L12/RHR STRAINER Xl-HBB-217-IA N/A AUG VT-3 100% NRI 540210 MAG-CG-425R4 MODULE Pump Suction Strainer 3/10/2003 N/A Performed in conjunction with suction Module . strainer exams. No measurable sludge build-up in this area.

VRR-2RD-2A N2F XI-VRR-2RD-2A N/A AUG UT 100% NRI 718100 GE-UT-209Vt2 Safe End to Nozzle 3/912003 N/A Insignificant and Non-relevant Ind.

(Az.210)

SS#4 VRR-2RD-2A N2G XI-VRR-2RD-2A N/A AUG UT 100% NRI 718400 GE-UT-209V12 Safe End to Nozzle 3/1012003 N/A Insignificant and Non-relevant ind.

(Az240)

SS#4 VRR-2RD-2B N2B XI-VRR-2RD-2B N/A AUG UT 100% NRI 716900 GE-UT-209V12 Safe End to Nozzle 3/11/2003 N/A Insignificant and Non-relevant ind.

(Az.60)

SS#4 VRR-2RD-2B N2C XI-VRR-2RD-2B N/A AUG UT 100% NRI 717200 GE-UT-209V12 Safe End to Nozzle 3/11/2003 N/A Insignificant and Non-relevant ind.

(Az.90)

SS#4 VRR-2RD-2B N2E XI-VRR-2RD-2B N/A AUG UT 100% NRI 717800 GE-UT-209V12 Safe End to Nozzle 3/11/2003 N/A Insignificant and Non-relevant ind.

(Az.150)

SS#4 Page 15 of 20 Monday, June 16.2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Outage: 2R07 Component ID Iso Number Sect. Xl Inspection Actual Code Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s) Exam Coverage Number Inspection Comments Item Cal Block DBA-212-1 FW20 XI-DBA-212-1 R-A Xl UT-E 100% RI 657100 GE-PDi-UT-1R3 4" Pipe to 24"x4" 3/8/2003 R1.11 2 recordable ind. ID Geometry Sweepolet LIM-4-.337-CS DCA-212-E2 W15 XI-DCA-212-E2 R-A Xl VT-2 100% NRI 693300 ER-AA-335-015R2 2" Elbow to Pipe 3/18/2003 R1.11 Examined by Exelon during System Pressure Test, No Leakage DCA-277-E1 W3 XI-DCA-277-E1 R-A Xl VT-2 100% NRI 610300 ER-AA-335-015R2 2" Pipe to Valve 43- 3/18/2003 R1.11 Examined by Exelon during System 2F051A Pressure Test, No Leakage DCA-418-3 FW1 XI-DCA-418-3 R-A Xl UT-E 100% NRI 347100 GE-UT-209V2 12" Pipe to Safe End 3/11/2003 R1.11 (Az.225 Deg.)

PART No. 21 & LIM-12-.688-SS316 DCA-419-1 FW2 XI-DCA-419-1 R-A Xi UT-E 100% NRI 014900 GE-PDI-UT-2R3 10" Pipe to Pipe 3/8/2003 R1.11 LIM-10-.593-SS316 EBB-208-2 FW13 XI-EBB-208-2 R-A Xi UT-E 100% RI 139800 GE-PDI-UT-1R3 12" Pipe to 12"xl0" 3/11/2003 R1.11 2 recordable ind. ID Geometry Eccentric Reducer LIM-12-.688-CS DCA-418-3 N17C XI-DCA-418-3 R-A Xi UT-E 100% NRI 723700 GE-UT-209V12 Safe End to Nozzle 3/11/2003 R1.11, AUG Insignificant and Non-relevant ind.

(Az.225 Deg.) R1.16 SS#4 DBB-203-1 FW6 XI-DBB-203-1 R-A Xi UT-E 100% NRI 120600 GE-PDI-UT-1R3 24" Pipe to Valve HV 3/13/2003 R1.11, AUG CB 1.6"upstream.

2F074A R1.18 LIM-24-1.812-CS DBB-204-1 FW2 XI-DBB-204-1 R-A Xl UT-E 100% RI 123400 GE-PDI-UT-1R3 Valve HV-41-2F032B to 3/10/2003 R1.11, AUG 2 recordable ind. ID Geometry 24"x 24"x 16" Reducer R1.18 ree LIM-24-1.812-CS DBB-204-1 FW4 Xl-DBB-204-1 R-A Xl UT-E 100% RI 124800 GE-PDI-UT-1R3

?4" X 24" X 16" Reducer 3/10/2003 R1.11, AUG ID Geometry ree to 16" Elbow R1.18 LIM-16-1.219-CS Page 16 of 20 Monday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Outage: 2R07 24" Pipe to Valve HV 3/9/2003 RI.11, AUG 1 recordable ind. ID Geometry 2F074B R1.18 LIM-24-1.812-CS DBB-204-1-IA SW2 XI-DBB-204-1 R-A Xi UT-E 100% NRI 123800 GE-PDI-UT-1R3 24-x 24"x 16" Reducer 3/10/2003 R1.11. AUG Previous Indications were below Tee to 24" Pipe R1.18 recording level LIM-24-1.812-CS DBB-204-1-IA SW7 XI-DBB-204-1 R-A Xi UT-E 89% NRI 124400 GE-PDI-UT-1R3 24" Pipe to 24"x 6" 3/9t2003 RI.11, AUG Sweepolet RI.18 LIM-24-1.812-CS DBB-204-1-IB SW4 XI-DBB-204-1 R-A Xi UT-E 100% RI 124000 GE-PDI-UT-1R3 16" Elbow to 16" Elbow 3/10J2003 RI.11. AUG 2 Indications, Root Geometry R1 .18 LIM-16-1.219-CS DBB-2041-18 SW5 XI-DBB-204-1 R-A Xi UT-E 100% NRI 124200 GE-PDI-UT-1R3 16" Elbow to Pipe 3110/2003 R1.11, AUG RI.18 LIM-1 6-1 .219-CS DLA-207-1 S4C XI-DLA-207-1 R-A Xi UT-E 100% NRI 109400 GE-PDI-UT-1R3 12'Pipe to Safe End 3/10/2003 RI.11, AUG Previous indications were below (GEXAz.150 Degrees) RI.18 recording level LIM-12-.688-CS-R & PART No. 8 DLA-208-1 S4D XI-DLA-208-1 R-A Xi UT-E 100% NRI 116600 GE-PDI-UT-1R3 12"Pipe to Safe End 3/9/2003 RI.11. AUG Previous indications were below (GEXAz210 Degrees) RI.18 recording level LIM-12-.688-CS-R & PART No. 8 HBB-201-1 FWi1 XI-HBB-201-1 R-A Xi UT-E 100% RI 318200 GE-PDI-UT-1R3 10"x 10x 8"Tee to 10 3/11/2003 RI.11, 2 recordable id. Root Geometry Pipe RI.18 LIM-10-.365-CS HBB-201-1 FWI2 XI-HBB-201-1 R-A Xi UT-E 53% RI 320400 GE-PDI-UT-1R3 8" Elbow to Pipe 3/9/2003 R1.11, 1 recordable ind. Root Geometry.

R1.18 Unable to scan over weld crown.

LIM-B-.322-CS HBB.201-1 FW13 XI-HBB-201-1 R-A Xl UT-E 100% NRI 320300 GE-PDI-UT-1R3 8" Elbow to Elbow 3/9/2003 R1.11, R1.18 LIM4.322-CS Page 17 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 10" x 8" Concentric 3/9/2003 R1.11, Reducer to 8- Elbow Ri .18 LIM-8-.322-CS HBB-201-1 FW15 XI-HBB-201-1 R-A Xi UT-E 100% RI 319600 GE-PDI-UT-1R3 8- Flange (20S-212 3/1112003 R1.1, 2 recordable ind. Root Geometry RCIC Turbine Exhaust) R1.18 to 10 xlOx8 Tee LIM-8-.322-CS HBB-201-1 FW2 XI-HBB-201-1 R-A Xl UT-E 100% RI 318300 GE-PDI-UT-1R3 10 Pipe to Elbow 3/9/2003 RI.11, 2 recordable ind. Root Geometry R1.18 LIM-10-.365-CS HBB.201-1 FW3 XI-HBB-201-1 R-A Xl UT-E 10% RI 318400 GE-PDI-UT-1R3 10" Pipe to Elbow 3/9/2003 R1.11, 2 recordable ind. Root Geometry RI.18 LIM-10-.365-CS HBB-208-1 FWI XI-HBB-208-1 R-A Xl UT-E 100%/ RI 161900 GE-PDI-UT-1R3 20- Pipe to Elbow 315/2003 R1.11. Root Geometry RI.18 LIM-20-.375-CS HBB-208-1 FW13 XI-HBB-208-1 R-A Xi UT-E 94% RI 162400 GE-PDI-UT-1R3 20" Pipe to Elbow 3/512003 RI.11, Root Geometry R1.18 LIM-20-.375-CS HBB-208-1 FW14 XI-HBB-208-1 R-A Xl UT-E 100% RI 163500 GE-PDI-UT-1R3 20- Pipe to Pipe 3/512003 R1.11, Root Geometry R1.18 LIM-20-.375-CS HBB-208-1 FWI5 XI-HBB-208-1 R-A Xi UT-E 100% NRI 163600 GE-PDI-UT-1R3 20` Pipe to Pipe 3152003 R1.11, R1.18 LIM-20-.375-CS HBB-208-1 FW3 XI-HBB-208-1 R-A Xl UT-E 100% RI 161800 GE-PDI-UT-1R3 G Elbow to Pipe 3/512003 Rt.11, Root Geometry RI.18 LIM-20-.375-CS lCA-204-2 FW1 XI-DCA-204-2 R-A Xl UT- 100% NRI 325400 ER-AA-335-004R1 WT

'Valve HV-51-2F015A to 3/111f2003 R1.13 FAC Exam >87.5% Nom. T

lued Head X-13A LIM-12-.688-SS316 ody ue1.20 85 f2

~~ ~

.~ ~ ~ ~ ~ ~ ~~~ae1 Page 18 of 20 Mornday, June 16, 2003 18:56

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Wr 18"x18"x18"Tee to 18" 3110/2003 R1.13 FAC Exam >87.5% Nom. T Pipe LIM-18-.500-CS GBB-218-4 FW2 XI-GBB-218-4 R-A Xi UT- 100% NRI 448400 ER-AA-335-004R1 WT 18"x18x18" Tee to 18' 31912003 R1.13 FAC Exam >87.5% Nom. T Pipe LIM-1 8-.500-CS APE-2MS-LA WAG XI-APE-2MS-LA R-A Xl UT-E 100% NRI 174500 GE-PDI-UT-1R3 Flued Head (X-7A) to 3/712003 R1.20 AUG Valve HV41-2F028A LIM-26-1.013 CS DBA-206-1-3B SW5 XI-DBA-206-1 R-A Xl UT-E 100% RI 127600 GE-PDI-UT-1R3 10"x 10 x 10Tee to 3/1312003 R1.20 AUG 1 recordable ind. ID Geometry 10" Pipe LIM-10-.593-CS DBA-206-1-3B SW6 XI-DBA-206-1 R-A Xl UT-E 100% RI 127800 GE-PDI-UT-1R3 10" Pipe to Elbow 3/13/2003 R1.20 AUG 1 recordable ind. ID Geometry LIM-10-.593-CS DBA-206-1-38 SW7 XI-DBA-206-1 R-A Xl UT-E 100% RI 128000 GE-PDI-UT-1R3 10" Elbow to Pipe 3113/2003 R1.20 AUG 1 recordable ind. ID Geometry LIM-10-.593-CS DCA-201-2 FW702 XI-DCA-201-2 R-A Xl UT-E 100% RI GE-PDI-UT-2R3 6" Pipe to Valve HV-044- 3/11/2003 R1.20 1 recordable ind. Root Geometry 2F004 LIM6.432-SS318 DCA-205-1 FW9 XI-DCA-205-1 R-A Xl UT-E 75% NRI 332200 GE-PDI-UT-2R3 Flued Head (X-12) to 3/10/2003 R1.20 Valve HV-51-2F008 LIM-20-.840-SS316NG DLA-210-1 FWI XI-DLA-210-1 R-A Xi UT-E 71% RI 025900 GE-PDI-UT-2R3 Valve HV-52-208 to 3112/2003 R1.20 3 recordable indications. ID Geometry Flued Head X-16B LIM-12-.688-SS316 EBB-203-1 FW2 XI-EBB-203-1 R-A xi LIT-E 100% RI 216400 GE-PDI-UT-1R3 26' Elbow to Pipe 3/9/2003 R1.20 AUG 1 recordable ind. Root Geometry LIM-26-.928-CS Page 19 of 20 Monday. June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 Outaae: 2R07 EBB-203-1 FW36 XI-EBB-203-1 R-A Xi UT-E 100% NRI 221300 GE-PDI-UT-1R3 26" Valve HV 3/7/2003 R1.20 AUG Previous indications were below 2F028A to 26" Pipe l.D. recording level.

23.647" Match Valve ID LIM-26-1.013-CS EBB-203-1-1 SW1 XI-EBB-203-1 R-A Xl UT-E 100% NRI 217000 GE-PDI-UT-1R3 26" Pipe to Elbow 3/9/2003 R1.20 AUG LIM-26-.928-CS Page 20 of 20 Monday, June 16, 2003 18:56

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Outaqe: 2R07 Component ID iso Number Sect. XI Inspector Actual Results Summary Procedure(s)

Description Insp. Date Cae Reason(s) Exam Coverage Number Comments I ~~~Item Li2/SA XI-BN-10 B-N-1 AUG VT-3 90% NRI GE-VT-204V6 Shroud Annulus Surfaces 3/10/2003 B13.10 Overall camera scan view showing RPV wall, across shroud ledge, and up the shroud wall.

L12/PIA XI-BN-8 NIA RE UT 40% NRI GE-UT-511V1O Core Spray "A' Loop N5B 3/9/2003 N/A Thermal Sleeve to T-Box Weld 300 Az L12/P1B XI-BN-8 N/A RE UT 40% NRI GE-UT-511V10 Core Spray B" Loop NSA 3/9/2003 N/A Thermal Sleeve to T-Box Weld 60 Az Li2JP2A XI-BN-8 NIA RE UT 100% NRi GE-UT-51 1V10 Core Spray A Loop 3/10/2003 N/A Header T-Box Cover Plate Weld 300 Az Li2P2B XI-BN-8 WA RE UT 100%/0 NRI GE-UT-511V10 Core Spray "B Loop 3/10/2003 N/A Header T-Box Cover Plate Weld 60 Az Li2/P3aA XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop 3/9/2003 N/A Header T-Box to Pipe Weld Right Side 300 Az Li2JP3aB XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "B" Loop 3/8/2003 N/A Header T-Box to Pipe Weld Righl Side 60 Az Li2P3bA XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray A Loop 3/9/2003 N/A Header T-Box to Pipe Weld Left Side 300 Az Li21P3bB XI-BN-8 NJA RE UT 100% NRI GE-UT-511V10 Core Spray "B" Loop 3/9/2003 N/A EVr-1 65% NRI Header T-Box to Pipe Weld Left Side 60 Az Supplemental visual examination performed to support evaluaion of ultrasonic indicabon.

Li2/P4cA XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray A" Loop "A 3/7/2003 N/A Downcomer Pipe to Elbow Weld 352.5 Az (Shroud Elevation)

LU2/P4cB XI-F-t N/A RE UT 100% NRI GE-UT-511V1O Core Spray B" Loop B' 3/8/2003 NA Downcomer Pipe to Elbow Weld 7.5 Az (Shroud Elevation)

Page I of 18 Monday, June 16, 2003 18:54

2 Limerick ISI Component Inspection Results Listing Interval:

Period: 1 Unit 2 Outage: 2R07 Li2/P4cC XI-BN-8 Core Spray "A" Loop "C" 3/8/2003 N/A Downcomer Pipe to Elbow Weld 187.5 Az (Shroud Elevation)

Li2/P4cD XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "B" Loop "D" 3/8/2003 N/A Downcomer Pipe to Elbow Weld 172.5 Az (Shroud Elevation)

Li2/P4dB XI-BN-8 N/A RE EVT-1 85% NRI GE-VT-204V6 Core Spray "B" Loop "B" 3/10/2003 N/A Downcomer Elbow to Shroud Pipe Weld 7.5 Az Li2/P5A XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop A' 3/7/2003 N/A Downcomer Pipe to Sliding Sleeve Field Weld 352.5 Az Li2/P5B Xi-BN-8 N/A RE UT 100% NRI GE-UT-51 1V10 Core Spray "B" Loop "B" 3/8/2003 N/A Downcomer Pipe to Sliding Sleeve Field Weld 7.5 Az Li21PSC XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop "C" 3/8/2003 N/A Downcomer Pipe to Sliding Sleeve Field Weld 187.5 Az Li2/P5D XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "B" Loop "D' 3/8/2003 N/A Downcomer Pipe to Sliding Sleeve Field Weld 172.5 Az Li2/P6A XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop "A" 3/7/2003 N/A Sliding Sleeve to Outer Sleeve Field Weld 352.5 Az Li2/P6B XI-BN-8 N/A RE UT 100% NRI GE-UT-51 1V10 Core Spray "B" Loop "B" 3/6/2003 N/A Sliding Sleeve to Outer Sleeve Field Weld 7.5 Az Li2/P6C XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop "C" 3/8/2003 N/A Sliding Sleeve to Outer Sleeve Field Weld 187.5 Az Li21P6D XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "B" Loop "D 3/8/2003 N/A Sliding Sleeve to Outer Sleeve Field Weld 172.5 Az Li2/P7A XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "A" Loop A" 3/7/2003 N/A Outer Sleeve to Pipe Shop Weld 352.5 Az Page 2 of 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval: 2 Period: 1 Unit 2 Outac. 2R07 Component ID Iso Number Sect. Xl lnspection Actual Results Summary Procedure(s)

Description Insp. Date Cat. Reason(s) Exam Coverage Number Commerts Li2/P7B XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray "B' Loop 'B' 3/8/2003 N/A Outer Sleeve to Pipe Shop Weld 7.5 Az L121P7C XI-BN-8 N/A RE UT 100% NRI GE-UT-5i1V10 Core Spray 'A' Loop "C" 3/8/2003 N/A Outer Sleeve to Pipe Shop Weld 187.5 Az Li2IP7D XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray 'B' Loop 'D' 3/8/2003 N/A Outer Sleeve to Pipe Shop Weld 172.5 Az LI 'P8aA Xl-BN-8 N/A RE EVr-1 100% NRI GE-VT-204%.V6 Core Spray 'A' Loop 'A' 3/10/2003 N/A Shroud Pipe to Collar Weld 352.5 Az Ll2IP8a8 XI-BN-8 N/A RE EVr-1 85% NRI GE-VT-204V6 Core Spray *B- Loop 'B" 3110/2003 N/A Shroud Pipe to Collar Weld 7.5 Az Li2/P8aC XI-BN-8 N/A RE EVT-1 90% NRI GE-VT-204V6 Core Spray 'A' Loop 'C" 3/10/2003 N/A Shroud Pipe to Collar Weld 187.5 Az L121P8aD XI-BN-8 N/A RE EVT-i 85% NRI GE-VT-204V6 Core Spray BW Loop "D" 3110/2003 N/A Shroud Pipe to Collar Weld 172.5 Az Li2JP8bA XI-BN-8 N/A RE UT 100% NRI GE-UT-51 1V10 Core Spray 'A' Loop 'A' 3/8/2003 N/A Collar to Shroud Weld 352.5 Az Li21PBbB X-BN-8 N/A RE UT 100% NRI GE-UT-511V1O Core Spray 'B- Loop 'B' 3/8/2003 N/A Collar to Shroud Weld 7.5 Az Li2/P8bC XI-BN-8 N/A RE UT 100% NRI GE-UT-51 Vi0 Core Spray 'A' Loop 'C' 3/8/2003 N/A Collar to Shroud Weld 187.5 Az Li2/P8bD XI-BN-8 N/A RE UT 100% NRI GE-UT-511V10 Core Spray 'B' Loop 'D- 318/2003 N/A Collar lo Shroud Weld 172.5 Az L12/PR4 XI-BN-8 NIA RE VT-I 100% NRI C-E-VT-204V6 Core Spray 'B' Loop "B 317/2003 N/A and D' Header Pipe Bracket 165 Az Page 3 of 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 1

Unit 2 Core Spray "A" Loop "A 3/10/2003 N/A and C" Header Pipe Bracket 195 Az Li21PB6 Xi-BN-8 N/A RE VT-i 100% NRI GE-VT-204V6 Core Spray "A" Loop "A 3/8/2003 N/A and C" Header Pipe Radial Bracket 247.5 Az Li2/S1A XI-BN-8 N/A RE EVT-1 100% NRI GE-VT-204V6 "A" Sparger T-Box Cover 3/9/2003 N/A Plate Weld (352.5 Az)

Li2/S1B Xi-BN-8 N/A RE EVT-1 100% NRI GE-VT-204V6 "B Sparoer T-Bnx Cover 3/9/2003 N/A Plate Weld (7.5 Az)

Li2/S2aA XI-BN-8 N/A RE EVr-1 60% NRI GE-VT-204V6 "A" Sparger T-Box to Pipe 3/9/2003 N/A Weld (Right Side) (352.5 Az)

Li2/S2aB Xi-BN-8 N/A RE EVT-1 60% NRI GE-VT-204V6 "B" Sparger T-Box to Pipe 3/9/2003 N/A Weld (Right Side) (7.5 Az)

Li21S2bA XI-BN-8 NIA RE EVT-1 60% NRI GE-VT-204V6 "A" Sparger T-Box to Pipe 3/9/2003 N/A Weld (Left Side) (352.5 Az)

Li21S2bB Xi-BN-8 N/A RE EVT-1 60% NRI GE-VT-204V6 "B" Sparger T-Box to Pipe 3/9/2003 N/A Weld (Left Side) (7.5 Az)

Li2/S3aXXC Xl-BN-8 N/A BL VT-i 90% NRI GE-VT-204V6 "C" Sparger Pipe to Nozzle 3/10/2003 N/A Weld, Typical of 65 Nozzles (XX) (93-267 Az)

Li2/S3bXXC Xi-BN-8 N/A BL VT-i 90% NRI GE-VT-204V6 "C" Sparger Nozzle to 3/10/2003 N/A Orifice Weld, Typical of 65 Orifices (XX) (93-267 Az)

Li2/S3dXXC XI-BN-8 N/A BL VT-i 90% NRI GE-VT-204V6 "C" Sparger Nozzle Stitch 3/10/2003 N/A Welds, 2 Welds 180 Deg Apt, 5 Pics Ea Noz. (93 -

267 Az)

Li2/S4aA XI-BN-8 N/A RE EVT-1 70% NRI GE-VT-204V6 "A" Sparger Pipe to End 3/10/2003 N/A Cap Weld (Right Side) (88 Az)

Li2/S4aB Xi-BN-8 N/A RE EVT-1 70% NRI GE-VT-204V6 "B" Sparger Pipe to End 3/10/2003 N/A Cap Weld (Right Side) (88 Az)

Page 4 of 18 Monday, June 16, 2003 18:54 a

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 I

Unit 2 Outace: 2R07 Component ID iso Number Sect. XI Inspectior Actual Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s)l Exam Coverage Number Comments Li2/S4bA I

XI-BN-8

~~~~item N/A RE EVT-1 75%

I NRI I

GE-VT-204V6

'A Sparger Pipe to End 3/9/2003 N/A Cap Weld (Left Side) (273 Az)

L12/S4bB XI-BN-8 N/A RE EVr-1 75% NRI GE-VT-204V6

'B Sparger Pipe to End 3/9/2003 N/A Cap Weld (Left Side) (273 Az)

Li21SBO1 XI-BN-8 N/A RE Vr-1 75% NRI GE-VT-204V6

'A and B" Sparger Bracket 3/9/2003 NA and Shroud Attachment Welds (7.5 Az)

LI2/SBO2 XI-BN-8 N/A RE VT-1 90% MRI GE-VT-204V6

'A arn E- Sparger Bracket 3/10/2003 N/A and Shroud Attachment Welds (44 Az)

Li2/SBO3 XI-BN-8 N/A RE VT-i 90% NRI GE-VT-204V6

'A and B" Sparger Bracket 3/10/2003 N/A and Shroud Attachment Welds (84 Az)

L12/SBO4 Xl-BN-8 N/A RE VT-i 90% NRI GE-VT-204V6

  • C and D Sparger Bracket 3/10/2003 N/A and Shroud Attachment Welds (96 Az)

L12/B05 Xl-BN-8 N/A RE VT-i 90% NRI GE-VT-204V6 "C and D' Sparger Bracket 3/1012003 N/A and Shroud Attachment Welds (136 Az) 1i2/SBO XI-BN-8 N/A RE VT-i 90% NRI GE-VT-204V6 "C and D Sparger Bracket 3/9/2003 N/A and Shroud Attachment Welds (172.5 AZ)

L12/H09 XI-BN-10 B-N-2 BL UT 10% NRI GE-UT-707V5 Core Shroud Suppot Plate 3/612003 B13.40 to RPV Weld Li21JPOI AD-1 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Adapter Top to 3/9/2003 N/A Adapter Bottom Weld -

Bimetallic Weld L121JPOI AD.2 XI-BN-04 N/A BL EVr-i 40% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/9/2003 N/A (Lower Ring) to Shroud Support Plate Weld L12/JPOI DF-t XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Collar Io 3/9/2003 N/A Diffuser Shell Weld L21IJP01 DF-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/9/2003 N/A Tailpipe Weld Page 5 of 8 Mornday, June 16, 2003 18:54 2

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 1

Unit 2 Li2/JP01 IN-4 XI-BN-04 Jet Pump Inlet to Mixer 3/9/2003 N/A Weld Li2/JP01 MX-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 319/2003 N/A Weld Li2/JP01-02 RS-1 Xl-BN-04 N/A BL EVT1 95% NRI GE-VT-204V6 Jet Pump Riser Elbow to 3/9/2003 N/A Thermal Sleeve Weld Li2/JPOI-02 RS-2 XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Elbow to 3/10/2003 N/A Riser Pipe Weld Li2/JP01-02 RS-3 Xl-BN-04 N/A BL VI -1 4U'Yo NRI GE-\T-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Transition Piece Weld L21JPOi-02 RS-6 XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Restrainer Bracket Circumferential Weld Li2/JPOi-02 RS-7 XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Restrainer Bracket Circumferential Weld Li2/JP01-02 RS-8 XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Riser Brace Circumferential Weld Li2/JP01-02 RS-9 Xi-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Riser Brace Circumferential Weld Li2/JP03-04 RS-3 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/7/2003 N/A Transition Piece Weld Li2/JP05 AD-1 XI-BN-04 N/A BL EVr-1 40% NRI GE-VT-204V6 Jet Pump Adapter Top to 3/9/2003 N/A Adapter Bottom Weld -

Bimetallic Weld i21JP05 AD-2 Xi-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/9/2003 N/A (Lower Ring) to Shroud Support Plate Weld Li2/JP05 BB-3 XI-BN-04 N/A SP EVT-1 100% NRI GE-VT-204V6 Jet Pump Hold Down 3/8/2003 N/A Beam Transition Region Visually examine the Transition Region the Jet Pump Hold Down Beam as a result of recent Industry Experience (Quad Cities).

Page 6 of 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 I

Unit 2 Outace: 2R07 Jet Pump Diffuser Collar to 3/9/2003 N/A Diffuser Shell Weld Li2/JPO5 DF-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 319/2003 N/A Tailpipe Weld L12/JPOS IN-4 Xl-BN-04 N/A BL EVr-1 50% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/8/2003 N/A Weld L12IJPO5 MX-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 3/9/2003 N/A Weld Li21JPOS-06 RB-Ia XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to RPV Pad Weld 12iJPo5-06 RB-lb XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/912003 N/A to RPV Pad Weld Ll2IJPO5-06 RB-Ic XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to RPV Pad Weld Li2JJPO5-06 RB-Id XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/912003 N/A to RPV Pad Weld Li2/JPOS-06 RB-2a XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld Li2IJP05-06 RB-2b XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld L12JPOS-06 RB-2c XI-BN-04 NIA BL EVr-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld Li2/JPO5-06 RB-2d XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld Li2/JPO5-06 RS-1 XI-BN-04 N/A BL EVT-1 90% NRI GE-VT-204V6 Jet Pump Riser Elbow to 3/9/2003 N/A Thermal Sleeve Weld LI2/JPO5-06 RS-2 XI-BN-04 N/A BL EVT-1 95% NRI GE-VT-204V6 Jet Pump Riser Elbow to 3/10/2003 N/A Riser Pipe Weld L121JP05-06 RS-3 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Transition Piece Weld Page 7 f 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 1

I I..d '

Juili £. Outage: 2R07 Component ID iso Number Sect. Xl Inspection Actual Results Summary Procedure(s)

Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Item Li2/JP05-06 RS-6 Xi-BN-04 N/A BL EVT-1 75% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Restrainer Bracket Circumferential Weld Li2/JP05-06 RS-7 Xl-BN-04 N/A BL EVT-1 75% NRI GE-VT-204V6 Jet Pump Riser Pipe to 319/2003 N/A Restrainer Bracket Circumferential Weld Li2/JP05-06 RS-8 XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Riser Brace Circumferential Weld Li2iJP06-06 R-59 Xi-6N-04 N/A BL E\T1 100% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 NiA Riser Brace Circumferential Weld Li2/JP06 AD-1 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Top to 3/9/2003 N/A Adapter Bottom Weld -

Bimetallic Weld Li2/JP06 AD-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/9/2003 N/A (Lower Ring) to Shroud Support Plate Weld Li2/JP06 BB-3 XI-BN-04 N/A SP EVT-1 100% NRI GE-VT-204V6 Jet Pump Hold Down 3/8/2003 N/A Beam Transition Region Visually examine the Transition Region the Jet Pump Hold Down Beam as a result of recent Industry Experience (Quad Cities).

Li2/JP06 DF-I XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Collar to 3/9/2003 N/A Diffuser Shell Weld Li2/JP06 DF-2 XI-BN-04 N/A BL EVT-1 30% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/9/2003 N/A Tailpipe Weld Li2/JP06 IN-4 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/9/2003 N/A Weld Li2/JP06 MX-2 Xl-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 3/9/2003 N/A Weld Li2/JP07-08 RS-3 Xl-BN-04 N/A BL EVT-1 60% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Transition Piece Weld Li2/JP09-1 0 RS-3 Xl-BN-04 N/A BL EVT-1 60% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/7/2003 N/A Transition Piece Weld Page 8 of 18 Monday, June 16, 2003 18:54

I I Limerick ISI Component Inspection Results Listing Interval:

Period: I 2

Unit 2 Outage: 2R07 Component ID Iso Number Sect. XI Inspection Actual Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s) Exam Coverage Number Comments Jet Pump Adapter Top to 3/612003 N/A Adapter Bottom Weld -

Bimetallic Weld Li21JP1I AD-2 XI-BN-04 N/A BL EVr-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/6/2003 N/A (Lower Ring) to Shroud Support Plate Weld LI21JPII DF-1 Xl-BN-04 N/A BL EVT-1 45% NRI GE-VI-204V6 Jet Pump Diffuser Collar to 3/6/2003 N/A Diffuser Shell Weld Li21JPII DF-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/612003 W/A Tailpipe Weld L12JJP11 IN-4 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/7)2003 N/A Weld Li21JPII MX-2 XI-BN'04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 3/72003 N/A Weld Li2/JPII-12 R3-la XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/1012003 N/A to RPV Pad Weld Li21JPII-1 2 RB-1b Xl-BN-04 N/A BL EVr-1 1000/e NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/1012003 N/A to RPV Pad Weld L21JPII-12 RB-Ic XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/1012003 N/A to RPV Pad Weld Li2/JPII-12 RB-Id XI-BN-04 N/A BL EVT-1 100% NRI GE-Vr-204V6 Jet Pump Riser Brace Leaf 3/10/2003 N/A to RPV Pad Weld Li21JPI1-12 RB-2a XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/10/2003 N/A to Yoke Weld Li21JPII-12 RB-2b XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3110/2003 N/A to Yoke Weld L12/JP11-12 RB-2c XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/10/2003 N/A to Yoke Weld 121JPi1-12 RB-2d XI-BN-04 N/A BL EVr-1 50% NRI GE-Vr-204V6 Jet Pump Riser Brace Leaf 3/1012003 N/A to Yoke Weld L12/JP11-12 RS-8 XI-BN-04 N/A BL EVT-1 70% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Restrainer Bracket Circumferential Weld Page9of 18 .

Monday, June 16, 2003 18:54~~~~~~~~~

Page 9 of 18 Monday, June 16. 2003 18:54

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 1

Unit 2 Outage: 2R07 Li21JP?1-12 RS-7 XI-BN-04 N/A Jet Pump Riser Pipe to 3/10/2003 N/A Restrainer Bracket Circumferential Weld Li21JP11-12 RS-8 Xi-BN-04 N/A BL EVT-1 95% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Riser Brace Circumferential Weld Li2/JP11-12 RS-9 Xl-BN-04 N/A BL EVT-1 95% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Riser Brace Circumferential Weld Li21JP12 AD-1 Xl-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Aaapter Top to 3/10/2003 N/A Adapter Bottom Weld -

Bimetallic Weld Li2/JP12 AD-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/10/2003 N/A (Lower Ring) to Shroud Support Plate Weld Li2/JP12 DF-1 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Diffuser Collar to 3/7/2003 N/A Diffuser Shell Weld Li2/JP12 DF-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/10/2003 N/A Tailpipe Weld Li2/JP12 IN-4 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/10/2003 N/A Weld Li21JP12 MX-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 3/10/2003 N/A Weld Li2/JP13 AD-1 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Top to 3/10/2003 N/A Adapter Bottom Weld -

Bimetallic Weld Li2/JP13 AD-2 Xl-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/10/2003 N/A (Lower Ring) to Shroud Support Plate Weld Li2/JP13 DF-1 Xl-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Diffuser Collar to 3/10/2003 N/A Diffuser Shell Weld Li21JP13 DF-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/10/2003 N/A Tailpipe Weld Li2/JP13 IN-4 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/10/2003 N/A Weld Page 10 of 18 Monday, June 16, 2003 18:54

Interval: 2 Limerick ISI Component Inspection Results Listing Period: I Unit 2 Jet Pump Barrel to Adapter 3/10/2003 N/A Weld Li2/JP13-14 RB-la XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to RPV Pad Weld Li21JP13-14 RB-lb XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to RPV Pad Weld Li2/JP13-14 RB-Ic XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to RPV Pad Weld Li2/Ji13-14 RB-Id XI-BN-04 NIA SL  : VT-1 100% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 319/2003 N/A to RPV Pad Weld Li2JJP13-14 RB-2a XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld L12/JP13-14 RB-2b XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld LI21JP13-14 RB-2c XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 NIA to Yoke Weld Li21JP13-14 RB-2d XI-BN-04 N/A BL EVT-1 50% NRI GE-VT-204V6 Jet Pump Riser Brace Leaf 3/9/2003 N/A to Yoke Weld Li2/JP13-14 RS-6 XI-BN-04 NIA BL EVT-1 75% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/10/2003 N/A Restrainer Bracket Circumferential Weld Ll2/JP13-14 RS-7 XI-BN-04 N/A BL EVT-1 70% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/912003 N/A Restrainer Bracket Circumferential Weld L121JP13-14 RS-8 XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Riser Brace Circumferential Weld Li21JP13-14 RS-9 XI-BN-04 N/A BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Riser Pipe to 3/9/2003 N/A Riser Brace Circumferential Weld L12/JP14 AD-1 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Adapter Top to 3/7/2003 N/A Adapter Bottom Weld -

Bimetallic Weld Page 11 of 18 Monday. June 16 2003 18:54

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Outage: 2R07 Component ID Iso Number Sect. XI Inspec Procedure(s)

Description lnsp. Date Cat. Reaso Comments Item Li2/JP14 AD-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Adapter Bottom 3/7/2003 N/A (Lower Ring) to Shroud Support Plate Weld Li2/JP14 DF-1 Xl-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Diffuser Collar to 3/7/2003 N/A Diffuser Shell Weld Li21JP14 DF-2 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Diffuser Shell to 3/9/2003 N/A Tailpipe Weld Li2/JP14 IN-4 XI-BN-04 N/A BL EVT-1 40% NRI GE-VT-204V6 Jet Pump Inlet to Mixer 3/9/2003 N/A Weld Li21JP14 MX-2 XI-BN-04 N/A BL EVT-1 45% NRI GE-VT-204V6 Jet Pump Barrel to Adapter 3/7/2003 N/A Weld Li2/45-03b N17A XI-BN-14 N/A BL EVT-1 80% NRI GE-VT-204V6 LPCI Coupling Shroud 3/9/2003 N/A Attachment Ring to Shroud Weld (045 Az)

Li2145-03b N17B XI-BN-14 N/A BL EVT-1 80% NRI GE-VT-204V6 LPCI Coupling Shroud 3/10/2003 N/A Attachment Ring to Shroud Weld (135 Az)

Li2/45-03b N17C XI-BN-14 N/A BL EVT-1 80% NRI GE-VT-204V6 LPCI Coupling Shroud 3/10/2003 N/A Attachment Ring to Shroud Weld (225 Az)

Li2/45-12 N17A Xl-BN-14 N/A BL EVT-1 20% NRI GE-VT-204V6 LPCI Coupling Sleeve 3/10/2003 N/A Flange to Thermal Sleeve Weld at RPV (045 Az)

Li2/45-12 N17B XI-BN-14 N/A BL EVT-1 20% NRI GE-VT-204V6 LPCI Coupling Sleeve 3/10/2003 N/A Flange to Thermal Sleeve Weld at RPV (135 Az)

Li2/45-12 N17C XI-BN-14 N/A BL EVT-1 20% NRI GE-VT-204V6 LPCI Coupling Sleeve 3/9/2003 N/A Flange to Thermal Sleeve Weld at RPV (225 Az)

Li2/45-12 N17D XI-BN-14 N/A BL EVT-1 20% NRI GE-VT-204V6 LPCI Coupling Sleeve 3/9/2003 N/A Flange to Thermal Sleeve Weld at RPV (315 Az)

Page 12 of 18 Monday, June 16, 2003 18:54 4

I Limerick ISI Component Inspection Results Listing Interval: 2 I

Period:

Unit 2 L12/CR/FS/GT-ARPIN-1 05-19 Fuel Support and Guide 3/812003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin Li2/CRiFS/GT-ARPIN-1 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 05-43 Fuel Support and Guide 319/2003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin Li2ICRIFSIGT-ARPIN-1 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 18-43 Fuel Support and Guide 3/912003 B13.40 Tube A.ignment Pin to Core Plate Weld, and Pin Li2/CR/FS/GT-ARPIN-1 Xl-BN07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 22-31 Fuel Support and Guide 3/2003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin L12/CR/FS/GT-ARPIN-1 XI-BN-07-4 B-N-2 BL Vr-3 100% NRI GE-VT-204V6 30-23 Fuel Support and Guide 3/8/2003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin L12/CR/FS/GT-ARPIN-1 XI-BN-07.4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 30-39 Fuel Support and Guide 3/9/2003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin Li2/CRlFSlGT-ARPIN-1 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 38-31 Fuel Support and Guide 3/8/2003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin L121CR/FS/GT-ARPIN-1 XI-BN B-N-2 BL VT-3 100% NRI GE-VT-204V6 42-19 Fuel Support and Guide 3/9/2003 B13.40 Tube Alignrnent Pin to Core Plate Weld, and Pin L12/CRIFSIGT-ARPIN-1 XI-BN B-N-2 BL VT-3 100% NRI GE-VT-204V6 42-43 Fuel Support and Guide 3/8/2003 813.40 Tube Alignment Pin to Core Plate Weld, and Pin L2/CRIFS/GT-ARPIN-1 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 54-43 Fuel Support and Guide 3/912003 B13.40 Tube Alignment Pin to Core Plate Weld, and Pin Page 13 of 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 I

I 1a. '

Ul1it Outage: 2R07 Component ID Iso Number Sect. Xl Inspectio Actual Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s Exam Coverage Number Comments Item Li2/CRGT-1 06-19 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 06-43 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 18-43 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 22-31 XI-BN-07-4 B-N-2 EL 'T-3 œ0noy NRl GE-\VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 30-23 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 30-39 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 813.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 38-31 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 42-19 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 42-43 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 813.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-1 54-43 XI-BN-07-4 B-N-2 BL VT-3 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Sleeve to Alignment Lug Weld Li2/CRGT-2 06-19 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Dnve Guide 3/8/2003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-2 06-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 813.40 Tube Body to Sleeve Weld Li2/CRGT-2 18-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Body to Sleeve Weld Page 14 of 18 Monday, June 16, 2003 18:54

Limerick ISI Component Inspection Results Listing Interval: 2 Period: I Unit 2 Outace: 2R07 Component ID Iso Number Sect. Xl Inspection Actual Results Summary Procedure(s)

Description nsp. Date Cat. Reason(s) Exam Coverage Number Comments I I ~~~~ ~ ~~~~Item LI2/CRGT-2 22-31 XI-BN-07-4 6-N-2 BL EVr-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Body to Sleeve Weld Li21CRGT-2 30-23 XI-BN-074 B-N-2 BL EVr-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 318/2003 B13.40 Tube Body to Sleeve Weld LU2/CRGT-2 30-39 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/912003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-2 38-31 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-2 42-19 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 319/2003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-2 42-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/2003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-2 54-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/912003 B13.40 Tube Body to Sleeve Weld Li2/CRGT-3 06-19 XI-BN-074 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 31/2003 B13.40 Tube Base to Body Weld L12/CRGT-3 06-43 XI-BN-074 B-N-2 6L EVr-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/912003 B13.40 Tube Base to Body Weld L121CRGT-3 18-43 XI-BN-074 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 31=2003 B13.40 Tube Base to Body Weld Li2/CRGT-3 22-31 XI-BN-074 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 31/82003 B13.40 Tube Base to Body Weld L12/CRGT-3 30-23 XI-BN-074 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Base to Body Weld Li2/CRGT-3 30-39 XI-BN-07-4 B-N-2 6L EVr-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Base to Body Weld L121CRGT-3 38-31 XIBN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 613.40 Tube Base to Body Weld LU2/CRGT-3 42-19 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/8/2003 B13.40 Tube Base to Body Weld Page 15 of 18 Monday. June 16, 2003 18:54

2 Limerick ISI Component Inspection Results Listing Interval:

Period: 1 Unit 2 Outage: 2R07 Component ID Iso Number Sect. Xl Inspectior Actual Results Summary Procedure(s)

Description Insp. Date Cat. Reason(s) Exam Coverage Number Comments Item Li21CRGT-3 42-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/912003 B13.40 Tube Base to Body Weld Li2/CRGT-3 54-43 XI-BN-07-4 B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Control Rod Drive Guide 3/9/2003 B13.40 Tube Base to Body Weld Li2/JP01-02 RBSP Xl-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Nos. 01 and 02 3/9/2003 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 23 and 38 Az)

Li2/JP03-04 RBSP Xi-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Nos. 03 and 04 3/7/2003 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 53 and 67 Az)

Li2/JP05-06 RBSP XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Nos. 05 and 06 3/9/2003 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 83 and 97 Az)

Li2/JPI1-12 RBSP XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Nos. 11 and 12 3/10/2003 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 203 and 217 Az)

Li2/JP13-14 RBSP XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Jet Pump Nos. 13 and 14 3/9/2003 B13.20 Riser Brace Support Pad Welds to RPV (2 Weld Buildup Locations 233 and 248 Az)

Li2/SSB 030 Deg Lower XI-BNN B-N-2 AUG VT-1 75% NRI GE-VT-204V6 Surveillance Specimen 3/9/2003 B13.20 Bracket Attachment Weld to RPV Li2/SSB 030 Deg Upper XI-BNN B-N-2 AUG VT-1 50% NRI GE-VT-204V6 Surveillance Specimen 3/9/2003 B13.20 Bracket Attachment Weld to RPV Li21CSB 165 Az XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Core Spray B and D" 3/7/2003 B13.30 Header Bracket (PB4)

Attachment Weld to RPV Page 16 of 18 Monday, June 16, 2003 18:54

I I I~~~

Limerick ISI Component Inspection Results Listing Interval:

Period:

2 Unit 2 Outage: 2R07 Component ID Iso Number Sect. Xl Inspection Actual Results Summary Procedure(s)

Description lnsp. Date Cat. Reason(s) Exam Coverage Number Comments I ~~~~ ~ ~~~~~Item Li2/CSB 195 Az XI-BNN B-N-2 BL EVr-1 100% NRI GE-VT-204V6 Core Spray 'A and C- 311012003 B13.30 Header Bracket (PB5)

Attachment Weld to RPV L2/CS8 247.5 Az XI-BNN B-N-2 BL EVT-1 80% NRI GE-VT-204V6 Core Spray A and C- 3/8/2003 B13.30 Header Radial Bracket (PB6) Attachment Weld to RPV Li2/FWSB 065 Az XI-BNN B-N-2 BL EVT-1 90% NRI GE-Vr-204V6 N4B Feedwater Sparger 3/7/2003 B13.30 Bracket Attachment Weld to RPV Li2/FWSB 115 Az XI-BNN B-N-2 BL EVT-1 90% NRI GE-VT-204V6 N4B Feedwater Sparger 3/7/2003 B13.30 Bracket Attachment Weld to RPV Li2/SDSB 004 Az XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Steam Dryer Support 3/6/2003 B13.30 Bracket Attachment Weld to RPV Li2ISDSB 094 Az XI-BNN B-N-2 BL EVT-1 100% NRI GE-VT-204V6 Steam Dryer Support 317/2003 B13.30 Bracket Attachment Weld to RPV Li2ISD XI-BN-01 N/A RE VT-3 100% NRI GE-VT-204V6, Steam Dryer Assembly 3/7/2003 N/A Welds, Surfaces & Lugs Li21SDDC XI-BN-01 N/A RE VT-i 100% NRI GE-VT-204V6 Stearn Dryer Drain Channel3/7/2003 N/A Welds, Vertical & Horizontal Li2JSDSR XI-BN-01 N/A RE VT-3 N/A RI GE-VI-204V6 Steam Dryer Support Ring 3/7/2003 N/A Examine and Document previous indication's @ aprox. 20 Az. Previously reported indication was examined and measured at approximately 2.25".

Li21SHISS XI-BN-02 N/A RE VT-3 70% RI GE-VT-204V6 Shroud Head/ Steam 3/9/2003 N/A Separator Assembly, 48 Shroud Head Bolts, Lugs.

Brackets, Welds and Surfaces Examined Lugs, Lifting Assembly, and 4e Shroud Head Bolts INR-LI2-04l-0 Rev. 1 Li21SSH 030 Deg XI-BN-12 N/A RE Vr-3 100% NRI GE-VT-204V6 Surveillance Specimen 3/912003 N/A Holder Page 17 of 18 Monday, June 16, 2003 18:54

Interval: 2 Limerick ISI Component Inspection Results Listing Period: 1 Unit 2 Surveillance Specimen 3/10/2003 N/A Holder Li2/SSH 300 Deg XI-BN-12 N/A RE VT-3 100% NRI GE-VT-204V6 Surveillance Specimen 3/10/2003 N/A Holder Li2/AHC 000 Deg Xl-BN-04 B-N-2 RE EVT-I 100% NRI GE-VT-204V6 Access Hole Cover Plate 3/10/2003 B13.40 and Weld to Shroud Support Plate Li2/AHC 180 Deg XI-BN-04 B-N-2 RE EVT-1 100% NRI GE-VT-204V6 Access Hole Cover Plate 3/1 0/2003 B13.40 and Weld to Shroud suprt F1!-*c Page 18 of I18 Monday, June 16, 2003 18:54

NIS-1 2R07 Section 2 Summary of Conditions Noted During Cycle 7 Inservice Inspection Examination and Tests April 21, 2001 to March 23, 2003

NIS-1 2R07 Section 2 Page 1 of 3 Summary of Conditions Noted Durng Cycle 7 Inservice Inspection Examination and Tests As a result of the examinations performed prior to and during the LGS Unit 2, 7th Refuel Outage, 2R07, there were no reportable conditions observed. Numerous other conditions were recorded and subsequent examinations and/or evaluations determined all conditions to be acceptable.

RPV Closure Head Meridional Weld Indication Summary Manual ultrasonic examinations from the outside surface of RPV closure head meridional welds 'DJ' and

'DH' were performed in accordance with the LGS Unit 2 ISI Program, Specification NE-027. This inspection is required for ASME Section XI.

Scanning for detection was performed in accordance with procedure GE-UT-300 Version 6. Interrogations for indication sizing were performed in accordance with procedure GE-UT-304 Version 3.

Weld DJ had 18 recordable indications. Twelve of the indications were determined to have through-wall dimension. The remaining 6 indications had no determinable through-wall component. All eighteen indications were evaluated and determined to be acceptable to the requirements of ASME Section XI, IWB-3500.

Weld DH had 2 recordable indications. Both indications were determined to have a through-wall dimension. Indication No.1 was in close proximity to the ID surface and a supplemental magnetic particle examination was performed from the near surface to ensure that the indication was not surface connected. Both indications were evaluated and determined to be acceptable to the requirements of ASME Section Xl, IWB-3500.

The indications in both welds were determined to be acceptable to the ASME Code without engineering (finite element) analysis. Accordingly, there are no structural integrity issues. An ECR is not required and operability was not an issue.

Previous ultrasonic examination results were reviewed. Indications were previously recorded in the area containing these indications however, they could not be directly correlated with the current indications.

Due to improvements in examination techniques this change in examination results is not considered to be indicative of changes in the condition of the weld or associated base material. The current examination techniques invoke a new standard (ASME Xl, Appendix Vil) which is considered to be more critical of the examination volume. The current indications do not represent abnormal degradation of the pressure boundary.

RPV O-Ring Indication Summary Inspection of the RPV flanges was performed in accordance with Owner Specified Criteria based on recent Industry Operating Experience. This inspection is not required for ASME or BWRVIP.

Two indications were recorded and found to meet the acceptance criteria of LGS ECR 02-00125,

'Acceptance Criteria for RPV O-Rings".

A Technical Evaluation was performed per AR A1407439 Evaluation 02.

All indications were determined to be acceptable and no structural integrity issues were identified. An ECR is not required and operability was not an issue.

NIS-1 2R07 Section 2 Page 2 of 3 Summary of Conditions Noted Durng Cycle 7 Inservice Inspection Examination and Tests Snubbers Functional Testing of snubbers was performed during 2R07 in accordance with LGS Unit 2 Technical Specification 4.7.4.e. and Surveillance Test ST-1 -103-300-2.

37 Mechanical snubbers (37 Plan), 17 Lisega Hydraulic snubbers (13.3% Plan), and 2 compensating struts (13.3% Plan) were selected for examination as part of the initial sample.

Of the Mechanical Snubbers tested there was one failure (DCA-204-H027, a PSA-35), All 17 Lisega Snubbers were functionally tested with no failures, and 2 Compensating struts were tested with no failures. The one Mechanical Snubber functional test failure resulted in an additional 19 snubbers being tested. There were no functional test failures in the expanded sample.

Regarding the failure of DCA-204-H027:

CR # 148064 was initiated to address the functional failure and Action Request Evaluation No.

Al 361523/E09 was initiated to provide the engineering evaluation required by LGS Technical Specification 4.7.4.g. The results of the engineering evaluation indicate that the piping and associated snubber were acceptable.

The pre-removal visual inspection of DCA-204-H027 revealed a cold setting of 5-9/16 inches that is 2-1/16 inches greater than the design cold setting of 3-1/2 inches. This condition has prompted the inspection of cold settings for several other snubbers connected to the same piping as DCA-204-H027 to determine the extent of condition of the piping displacement. No other snubber cold settings were found to be out-of-tolerance. Replacement of the HV-051-2F050 valves during a previous outage was determined to be the most likely cause of the snubber cold set problem.

Shroud Head Bolt Indication Summary Augmented ISI of the shroud head bolts was performed in accordance with the LGS Unit 2 ISI Program, Specification NE-027. This inspection is not required for ASME or BWRVIP.

Ten indications were recorded and found to meet the acceptance criteria of Specification NE-027.

CR# 00148196 was initiated to document the indications, apparent cause, corrective action, and extent of condition as required per LS-AA-125.

A Technical Evaluation was performed per A/R Al 407435 Evaluation 01.

All indications were found to be acceptable and no structural, bolted connection or loose parts concems exist. An ECR is not required and operability was not an issue.

Core Shroud During the baseline ultrasonic examination (UT) of the LGS Unit 2 core shroud, performed during 2R05, indications considered indicative of intergranular stress corrosion cracking were detected in six of the seven (7)horizontal welds (i.e. girth welds Hi, H2, H3, H4, H5, and H6).

The condition of the core shroud identified during 2R05 was evaluated per NCR LG 99-01153. An updated structural margin analyses, considering additional cycles of crack growth rate and the latest USNRC approved Industry Guidelines, was performed to ensure the condition of the core shroud remained analyzed. The attached report GE-NE 0000-0006-2250-04a, Revision 0, "Structural Evaluation of Core

NIS-1 2R07 Section 2 Page 3 of 3 Summary of Conditions Noted During Cycle 7 Inservice Inspection Examination and Tests Shroud Welds at Limerick Generating Station, Unit 2," was prepared using bounding crack growth rates approved by the USNRC in their Safety Evaluation Reports to BWRVIP-01 and BWRVIP-14. Results of the engineering analysis showed that structural integrity criteria are satisfied through Li2R1O in 2009 for all horizontal welds. Although the structural margins have been demonstrated to be maintained through Li2R10 using USNRC approved Industry Guidelines the reinspection of the LGS, Unit 2, core shroud has been scheduled for six years, Li2RO8 in 2005 based on the requirements of BWRVIP-76 for acceptance by site-specific analysis.

GE NuclearEnergy ENGINEERING & TECHNOLOGY GE-NE-0000-0006-2250-04a,Rev. 0 GE Nuclear Energy DRF0000-0006-2250 175 Curtner Avenue, San Jose, CA 95125 Class IX June 2003 STRUCTURAL T AUA

" TION OF CORE SHROUD WELDS AT LIAMERICK GENERATING STATION, UNIT 2 June 2003 Prepared for Exelon Corp.

Limerick 2 Generating Station

t10 GENE 0000-0006-2250-04a, Re. o STRUCTURAL EVALUATION OF CORE SHROUD WELDS AT LIMERICK GENERATION STATION, UNIT 2 June 2003 Prepared by:

D. Wu Approved by: 1 l v ia R.M. Horn, Manager Structural Mechanics & Materials

GENE 0000-00062250-04a,Rev. 0 PROPRIETARY INFORMATION NOTICE This is a non-proprietary version of the document GE-NE-0000-0006-2250-04, Rev.0, which has proprietary information deleted. The deleted information is identified by sidebars in the right margin next to the affected text, tables and figures. This paragraph has a sidebar as an example.

Stand-alone GE proprietary infonnation is identified by sidebars in the right margin next to the affected text, tables and figures containing stand-alone proprietary information. This paragraph has a sidebar as an example. Specific information that is not so marked, when taken out of the context of this report, is not GE proprietary.

IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT Please Read Carefully The only undertakings of the General Electric Company (GE) respecting information in this document are contained in the contract between Exelon Corporation and GE, No. 00055559, effective 02/07/03, as amended to the date of transmittal of this document, and nothing contained in this document shall be construed as changing the contract. The use of this information by anyone other than Exelon, or for any purpose other than that for which it is furnished by GE, is not authorized; and with respect to any unauthorized use, GE makes no representation or warranty, express or implied, and assumes no liability as to the completeness, accuracy, or usefulness of the information contained in this document, or that its use may not infringe privately owned rights.

Copyright, General Electric Company, 2003

GENE 0000-0006-2250-04a, Rev. 0 Table of Contents Subect Page No.

1. EXECUTIVE

SUMMARY

. . . .1...................

2. INTRODUCTION & BACKGROUND . .................................. 2
3. SHROUD GEOMETRY AND MATERIAL INFORMATION .. 2
4. FLUENCE LEVELS AT VAUOUS SHROUD WELDS . 2
5. PLANT'%WATER CHEMISTRY . .................................. 3
6.

SUMMARY

OF INSPECTION RESULTS ............................... . 3

7. APPLIED LOADS AND STRESSES AT VARIOUS WELDS .. 3 7.1. Dead Weight (DW) . . . 4 7.2. Differential Pressure Loads (DP, DP . ......................... - ... 4 7.3. Seismic Loads (OBE, SSE) . . .4 7.4. Safety Relief Valve Discharge Hydrodynanic Loads (SRV, SRVAM) ........................................... 4 7.5. Annulus Pressurization (AP) . . . 5 7.6. Acoustic Load (AC) and Flow lnduced Load (FIL) . . .

7.7. Fuel Lift Loads (FIL., LLf) . . . 6

8. CALCULATED STRESSES . . .................................. 6
9. STRUCTURAL MARGIN EVALUATION .................................... 6 9.1. Crack Growth Calculation . . .7 9.2. Evaluation of Hl Weld ..................................... 7 9.3. Evaluation of H2 Weld ............................. 7
94. Evaluation of H3 Weld .................. 8 9.5. Evaluation of H4 Weld ... 8 9.6. Evilualion of H6 Weld . . . 8 9.7. Sunmaiy of Evaluation Results ....................... . 9
10.

SUMMARY

AND CONCLUSIONS ....... .................................................. 9 I i. REFERENCES .. ........................................................ 10 APPENDIX A - SHROUD & WELDS GEOMETRY . ........................... 15 APPENDIX B- STRUCTURAL MARGIN CALCULATIONS FOR HI ................. 17 APPENDIX C-STRUCTURAL MARGIN CALCULATIONS FOR H2 .. 18 APPENDIX D-STRUCTURAL MARGIN CALCULATIONS FOR H3 .. 19 APPENDIX E-STRUCTURAL MARGIN CALCULATIONS FORH4 ................... 20 APPENDIX F- STRUCTURAL MARGIN CALCULATIONS FOR H6 .. 21 APPENDIX G- INSPECTION RECORDS OF WELDS HI THROUGH H7 .......... 22

GENE 0000-00062250-04a,Rev. 0 Table Paee No.

Table I Weld Geometries and Elevations .......................................................... 11 Table 2 Governing Load Combinations .......................................................... 12 Table 3 Calculated Membrane and Bending Stresses of Governing Load Case ....... 13 Table 4 Calculated Safety Factor Comparison .......................................................... 14 Fige . Pa2e Figure A-1: Shroud Circumferential Welds HI Tbrough H7 (Weld details not included)

.................................................................................................................... . ..................... 16

GENE 0000-00062250-04a,Rev. 0

1. EXECUTIVE

SUMMARY

The core shroud welds at the Limerick Generating Station, Unit 2 (LG2) were inspected during the refueling outage at the end of fuel cycle 5 (1999). Intergranular stress corrosion cracking (IGSCC) was detected at several horizontal welds. The objective of this report is to document the results of the structural evaluation of the cracked shroud welds to demonstrate compliance with BWRVIP-76 [3]. Horizontal welds HI through H7 were evaluated. The echnical evaluations considered the effects of power uprate (PU). It is shown that continued operation in the 'as-is' condition can be justified for at least 3 cycles of operation (end of fuel cycle 8). Although all horizontal shroud welds have been justified for 5 cycles of continued operations (end of fuel cycle 10) based on inspection results of end of cycle 5 (1999), re-inspection of the shroud welds is reconmended at the end of cycle 8. This shroud weld re-inspection interval of 6 years conservatively took into consideration the uncertainties associated with crack growth rates and possible new crack initiations.

I

GENE 0000-0006-2250-04a, Rev. 0

2. INTRODUCTION & BACKGROUND The core shroud welds at LG2 were inspected by UT during the refueling outage at the end of fuel cycle 5 (1999). Figure A-] shows a schematic of the various horizontal welds.

Elevation and inside diameter of each weld evaluated are also shown. IGSCC was detected at several horizontal welds. References I and 2 had provided justification for continued operation of the shroud to end of fuel cycle 7 based on evaluations of the limiting H4 weld. The objecti.e of this report is to document the results of the structural evaluation of the cracked shroud welds HI through H6 to demonstrate compliance with BWRVIP-76 [3]. It is shown that continued operation in the 'as-is' condition at these welds can be justified for at least 3 cycles of operation (end of fuel cycle 8).

3. SHROUD GEOMETRY AND MATERIAL INFORMATION The shroud and horizontal welds geometry information is summarized in Figure A-1 of Appendix A. Figure A-I shows the locations of various welds. The shroud material is SA-240 Type 304L stainless steel (Sm = 14400 psi). The shroud diameter, thickness and elevation for each of the horizontal welds are shown in Table 1. A review of the fabrication information indicates that the H7 weld was made at the LGS site, and it connected the prefabricated core shroud structure to the reactor pressure vessel.
4. FLUENCE LEVELS AT VARIOUS SHROUD WELDS The fluence calculations for the H4 weld were reported in Reference 4. The fluence values for H3 weld were extrapolated conservatively from the H4 fluence calculations.

The luence distributions in all the quadrants are identical. For the purpose of structural margin analysis, the metal between azimuths where the fluence levels exceed 3x1020 n/cm' were conservatively removed (i.e., assumed to be thTough-wall cracks). The remaining ligaments were calculated based on crack growth Tates and inspection uncertainties.

2

GENE 0000-00 06-2250-04a, Rev. 0

5. PLANT WATER CHEMISTRY The Limerick Generating Station, Unit 2 (LG2), has been operating with at least 90%

availability of effective Hydrogen Water Chemistry (HWC) since Apil 2000. The reduced flaw growth rate was used in the structural evaluations accordingly. For operating period from 5/1999 to 4/2000, Normal Water Chemistry (NWC) condition was assumed, and nornal flaw growth rate was used in the calculation of shroud flaws.

6.

SUMMARY

OF INSPECTION RESULTS The Ultrasonic (UT) inspection results for the various horizontal welds are documented in Reference 5. The UT inspections were conducted using the procedures outlined in Demonstration Number 16 in Reference 6.

UT measurement uncertainties associated with Demonstration Number 16 were added to the reported values of indication depths and lengths. The UT uncertainty in the depth direction was taken as 0. 131 inch. The length uncertainty was assumed as 0 degrees, that corresponds to 45° shear wave case. For flaws whose lengths were determined through more than one setting, the placement uncertainty is 0.5 degree. This value was conservatively added at the both ends of all found flaws.

7. APPLIED LOADS AND STRESSES AT VARIOUS WELDS All applicable loads and the critical load combinations used in the evaluation were consistent with the Core Shroud Loads at Horizontal Welds HI through HE report [7].

The load magnitudes used have considered the impact of power uprate. The goveming applicable loads and load combinations evaluated are as shown in Table 2. A brief description of the various loads is provided next.

3

GENE 0000-0006-2250-04a,Rev. 0 7.1. Dead Weight (DW9 Dead weights were based on the input to seismic and dynamic horizontal mathematical model shown in GE drawing 794E776. These are dry metal weights and include appropriate hardware weights.

7.2. DiffereniialPressureLoads (DP^,, DPJ The differential pressures (Delta Ps) across the Core Plate, Top Guide, and the Shroud Head impart vertical upward loading on the horizontal shroud welds. The differential pressure values across these components are obtained from previous evaluations including power uprate evaluation performed for LG2 as indicated in GE report No.GENE-B13-02066-00-02-LTI[7]. The pressures are multiplied by the net area of resistance of the above components in order to deternine the pressure loads across them in the Upset (DP) and and Faulted (DP ) conditions. The welds H1 and H2 are subjected to the Shroud Head Delta P load; H3, H4, and H5 are subjected to the Delta P loads across Shroud Head and Top Guide; Welds H6 and H7 are subjected to Delta P loads across the Shroud Head, Top Guide, and the Core Plate.

7.3. Seismic Loads (OBE, SSE)

The upset condition Operating Basis Earthquake (OBE) loads and the faulted condition Safe Shutdown Earthquake (SSE) loads at each weld location, in the horizontal and vertical directions, were obtained from the Reference 7 analysis report. Both North-South and East-West seismic horizontal motions were considered. All seismic loads reported were generated using time history analysis and peak time history responses.

7.4. SafeO' Relief ValveDischargeHydrodynamicLoads (SR V, SRJADS)

The hydrodynamic loads induced as a result of the actuation of all Safety Relief Valves (SRV) and the loads induced by the actuation of the Safety Relief Valves associated with 4

GENE 0000-0006-2250-04a, Rev. 0 the Automatic Depressurization System (SRVADS ) were included in the evalution. These loads (vertical load and lateral moment) were obtained from the Reference 7 evaluation basis report. Enveloped SRV loads for symmetric and asymmetric conditions were used in the calculations. All SRV loads reported were generated using time history analysis and peak time history responses.

7.5. Annulus Pressurization(AP)

Due to the loss-o'-coolant accident (LOCA) associated with the postu!2ted rupture of recirculation outlet or feedwater piping in the vessel-to-shield wall annulus, an asynmetric, lateral, transient pressure load (i.e., Annulus Pressurization load, AP) is imparted on the reactor vessel. Since the main steam line is above the shield wall, AP load does not apply to main steam line break LOCA. These loads were obtained from the Reference 7 evaluation basis report. There are no vertical loads associated with AP condition. All AP loads reported were generated using time history analyses and peak time history responses.

7.6. AcousticLoad (AC) and FlowInducedLoad (FIL)

As a result of the postulated rupture of the recirculation suction line, the shroud is subjected to asymmetric lateral load towards the break location. This lateral loading is made up of the initial acoustic phase (AC) followed by the steady state flow induced load (FIL). These two phases of the load are mutually exclusive based on the timing of their occurrence. For the purpose of the flaw evaluation, the lateral acoustic and flow induced loads on the shroud were generated at each horizontal weld location. The flow induced loads were generated using TRACG based methodology and applying the various power/flow conditions. It should be noted that since the acoustic loads are higher than AP load at certain weld locations, they were used in the load combination Tesults shown in the Table 2.

5

GENE 0000-0006-2250-04a, Rev. 0 7.7. Fuel Liff Loads (FLL,, FLLd Fuel lift loads (FLL) are imparted on the Core Plate and the Top Guide, which in turn result in vertical upward loads on the shroud at these component locations. The fuel lift loads documented during Reference 7 report evaluation remain bounding, and hence the FLL from the Reference 7 evaluation for the Upset (FLLu) and Faulted (FLLf) conditions are used in this flaw evaluation. The total fuel lift load consists of load from 4 fuel assemblies per guide tube and 185 guide tube assemblies. Further, the total fuel lift load thus calculated at top guide is added to other dynamic loads for welds HI through H4.

Similarly the total fuel lift load thus calculated at the core plate plus the guide tube together are added to the other dynamic loads for welds H5 through H8. All fuel lift loads were generated using time history analysis, and peak time history responses.

8. CALCULATED STRESSES The vertical axial loads resulting in Primary Membrane Stresses (Pm) and the lateral moment loads resulting in Primary Bending (Pb) stresses, are considered in the evaluation at each weld loaction from HI through H7. Table 3 shows the calculated values of Pm and Pb at the horizontal welds for various load combinations.
9. STRUCTURAL MARGIN EVALUATION The structural margin evaluation was conducted using the guidelines provided in Reference 3. A key input in calculating the remaining ligament at a weld, is the assumed crack growth rate during the inspection inierval. The crack growth calculation is described next followed by the summary of the structural evaluation results for the horizontal welds Hl, H2, H3, H4 and H6. Since weld H5 had only minor flaws found and H7 has no flaw found in 1999 inspection, they were simply dispositioned to the end of cycle 10 utilizing the acceptance standard established in Table 2-1 of Reference 3.

6

GENE 0000-0006-2250-04a,Rev. 0 9.1. Crack Growth Calculation As prescribed in Reference 3 and 8, the crack growth rates used in the length direction was 5x10-5 in/hr and in the depth direction was l.lxl0 5 in/hr under Hydrogen Water Chemistry (HWC) and 2.2x105 in/hr under Nornal Water Chemistry (NWC). In the depth direction, with 90% Hydrogen Water Chemistry (HWC) availability starting April2000, the crack growth rate was calculated based on NWC from May/1999 to March/2000 and HWC from April/2000 onward. The planned length of operation cycle is 24 months. Assuming approximately 90% availability, 24 months translate into approximately 16,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> of hot operation. The assumption regarding 90% availability is based on historic data. Given the conservative nature of the evaluation, the required structural margins are expected to be maintained even with slightly higher than 90%

availability during the next cycle. Only the length direction crack growth is used for areas where through-wall cracking is assumed.

9.2. Evaluation of HI Weld The crack depths at OD and ID were calculated using the guidance provided in Appendix I of Reference 3. All un-inspected regions were conservatively assumed o he cracked through wall. Since the fluence at this weld is calculated to be less than 3x I0'~ at the end of Cycle 10, only limit load evaluation using the computer program DLL [9] was conducted. The details of the structural margin calculation are included in Appendix B and the limiting case margin is shown in Table 4.

9.3. Evaluation of H2 Weld The crack depths at OD and ID were calculated using the guidance provided in Appendix I of Reference 3. All un-inspected regions were conservatively assumed to be cracked through wall. Since the fluence at this weld is calculated to be less than 3x102 0 at the end of Cycle 10, only limit load evaluation using the computer program DLL [9] was 7

GENE 0000-0006-2250-04a, Rev. 0 conducted. The details of the structural margin calculation are included in Appendix C and the limiting case margin is shown in Table 4.

9.4. Evaluation of H3 Weld The crack depths at OD and ID were calculated using the guidance provided in Appendix I of Reference 3. All un-inspected regions were conservatively assumed to be cracked through wall. The fluence level at H3 weld was extrapolated from the fluence distribution at H4 weld reported in Reference 4. As per the guidance provided in ApDendix D (Paragraph D.l.) of Reference 3, through-wall crack depth was assumed in regions where the calculated fluence exceeded 3x 1020 n/cm 2 at the end of Cycle 10. This obviates the need for linear elaslic fracture mechanics evaluation. Therefore, only the limit load evaluation was conducted using the computer program DLL. The details of the structural margin calculation are included in Appendix D and the limiting case margin is shown in Table 4.

9.5. Evaluation of H4 Weld The crack depths at OD (look-up and look-down) and ID (look-up and look-down) were calculated using the guidance provided in Appendix ] of Reference 3. All un-inspected regions were conservatively assumed to be cracked through wall. As per the guidance provided in Appendix D (Paragraph D.].1) of Reference 3, through-wall crack depth was assumed in regions where the calculated fluence exceeded 3x1020 n/CM2 at the end of Cycle 10. This obviates the need for linear elastic fracture mechanics evaluation.

Therefore, only the limit load evaluation was conducted using the computer program DLL. The details of the structural margin calculation are included in Appendix E and the limiting case margin is shown in Table 4.

9.6. Evaluation of H6 Weld The crack depths at OD and ID were calculated using tht guidance provided in Appendix I of Reference 3. All un-inspected regions were conservatively assumed to be cracked through wall. Since the fluence at this weld is calculated to be less than 3x10 20 at the end of Cycle 10, only limit load evaluation using the computer program DLL was conducted.

8

GENE 00000006-2250-04a,Rev. 0 The details of the structural margin calculation are included in Appendix F and the limiting case margin is shown in Table 4.

9.7. Summary of Evaluation Results The calculated values of structural safety factors at the HI, H2, H3, H4 and H6 welds for the limiting operating condition are summarized in Table 4. A comparison with the required values indicates that all of the calculated safety factor values exceed the required values. Based on this it is concluded that the required safety margins at the HI, H2, H3, H4 and H6 welds are maintained in the 'as is' condition to the end of Cycle 10.

However, the reconmended re-inspection interval for the welds that were qualified by plant specific analyses (Hl through H4 and H6) is 6 years to end of cycle 8, taking into account of the uncertainties of possible new crack initiation and crack growth.

10.

SUMMARY

AND CONCLUSIONS The core shroud welds at the LG2 were inspected during the refueling outage at the end of Fuel Cycle 5 (1999). This report documents the results of the structuTal evaluation of the cracked shroud welds to dernonstrate compliance with BWRVIP-76 3]. Specifically, horizontal welds HI, H2, H3, H4 and H6 were evaluated. H5 and H7 were simply dispositioned using guidelines provided in Table 2-1 of Reference 3. The technical evaluations considered the effects of power uprate (PU). It is shown that continued operation in the 'as-is' condition at these welds is technically justified for at least 3 cycles of operation (end of Fuel Cycle 8) assuming normal water chemistry operation until April of 2000, and effective hydrogen water chemistry operation from then on.

9

GENE 0000- 0 006-2250-04a,Rev. 0

11. REFERENCES
1. GENE-B13-02080-00-03, August 2000, "The Evaluation of Limerick Unit 2 Shroud H4 Cracking for Two Fuel Cycles of Operation".
2. GENE-B13-02080-00-03 LTRI, February 2001, "Justification for Continle Operation of Limerick Unit 2 Through RF07".
3. "BWR Vessel and Intemals Project: BWR Core Shroud Inspection and Flaw Evaluation Guidelines (BWRVIP-76)," EPRI Report No. TR-1 14232, November 1999.
4. GENE-BI 1-00842-00-01, July 2001, "Limerick/Peach Bottom Neutron Flux Evaluation."
5. GENE Report No. H61R, Revision 0, May 1999, "Limerick Generating Station -

Unit 2, Core Shroud Ultrasonic Examination."

6. "BWR Vessel and Internals Project, Reactor Pressure Vessel and Intemals Examination Guidelines," (BWRVIP-03), Revision 3, December 2000.
7. GENE-B13-02066-00-02-LTI, September 2000, "Core Shroud Loads at Horizontal Welds HI through H8."
8. "BWR Vessel and Intemals Project, Reactor Pressure Vessel and Internals Examination Guidelines," (BWRVIP-14), EPRI Report No. TR-105873, March 1996.
9. "BWR Core Shroud Distributed Ligament Length (DLL) computer Program (Version 2.1 , (BWRVIP-20), EPRI Report No. TR-l 07283, December 1996.

10

GENE 0000-0006-2250-04a, Rev. 0 Table I Weld Geometries and Elevations Weld ID Wall Elevalion Thickness from at Weld Vessel L ocation _Zero in. i in. I n.

HI 216 2.0 398.00 H2 216 2.0 362.375 H3 203.125 2.0 359.875 H4 203.125 2.0 299.125 H5 203.125 2.0 191.125 H6 196.75 2.0 186.875 H7 196.75 2.0 131.50 11

GENE 0000-0006-2250-04a,Rev. 0 Table 2 Governing Load Combinations Servic Level Service Load Combination Condition B Upset NL + DPu + OBE + SRV + FLLuveica, C Emergency NL + DPu + LOCA SRV + FLLu,veni,,l D I Faulted DW + DPu + SSE + AP NL = Normal Load DPU = Delta P - Upset OBE = Operating Basis Earthquake SSE = Safe Shutdown Earthquake SRV = Safety Relief Valve Actuation (all valves) Hydrodynamic Load DW = Dead Weight AP = Annulus Pressurization Load (includes Jet Reaction. where applicable)

LOCA = Loss of Coolant Accident FLLu = Fuel Lift Load in the Upset and Fi'h -  : ;tuons 12

GENE 0000-0006-2250-04a,Rev. 0 Table 3 Calculated Membrane and Bending Stresses of Governing Load Case Units: psi Weld NormalUpset Condition Emergency/Faulted Condition Pm Pb Pm Pb Hi1 334.9 482.6 808.2 813.8 H2 334.9 651.5 808.2 1089.5 H3 356.0 753.1 858.9 1258.8 H4 356.0 1165.6 858.9 1985.9 H5 356.0 2153.9 858.9 3712.1 H6 674.7 2343.9 1203.0 4036.7 H7 674.7 2946.1 1203.0 5273.7 13

GENE 0000-0006-2250-04a,Rev. 0 Table 4 Calclalated Safety Factor Comparison Weld ID Governing Required Safety Calculated Safety Operating Condition Factor Factor HI Faulted 1.39 2.20 H2 Faulted 1.39 11.11 H3 Faulted 1.39 1.53 H4 Faulted 1.39 2__R_6l H6 Faulted 1.39 3.42 l 14

I I GENE 0000-0006-2250-04a, Rev. 0 APPENDIX A - SHROUD & WELDS GEOMETRY i5

GENE 0000-0006-2250-04a, Rev. 0 Shroud Upper Flange -*

Hi elev 398.00)

R=108.0 H2 (elev 362.376) i Top Guide Ring - E- j H3 (ev 359.875)

R 101.56 P H4 (299.125)

H5 (191.125)

Core Support Ring-_ /

H6 (1685 Shroud Support Cylinder >

Shroud Support Leg (12 Pls)

Plate Figure A-1: Shroud Circumferential Welds HI Through H7 (Weld details not included) - Units: inches 16

GENE 0000-0006-2250-04a,Rev. 0 APPENDIX B- STRUCTURAL MARGIN CALCULATIONS FOR HI 17

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/16/2002

SUMMARY

OF INPUTS:

Title:

Limerick 2 H EOC10 EF LLR Angle increment = 1.0 deg. (COARSE)

Membrane Stress, Pm = 808. psi Bending Stress, Pb = 814. psi Safety Factor, SF - 1.39 Mean Radius, Rm = 109.00 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm - 14400. psi Fluence - 0.OE+00 n/cm^2 (Thus, LEFM evaluation not applicable)

THETAI THETA2 THICKNESS REGION (deg.] [deg.] [inches) 1 2.3 9.5 2.000 2 181.9 203.4 2.000 3 233.8 235.9 1.990 4 246.8 259.3 2.000 5 283.2 291.8 2.000 LIMIT LOAD RESULTS:

3s==s=ss==aaaa=

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY

[deg] lin-lbs) [psi] FACTOR RESULT

.0 1.243E+09 16645. 10.76 ---->ACCEPTABLE 5.0 1.214E+09 16263. 10.52 ---->ACCEPTABLE 10.0 1.182E+09 15837. 10.26 ---- >ACCEPTABLE 15.0 1.147E+09 15370. 9.97 ---- >ACCEPTABLE 20.0 1.11OE+09 14867. 9.66 ---- >ACCEPTABLE 25.0 1.070E+09 14331. 9.33 ---- >ACCEPTABLE 30.0 1.028E+09 13766. 8.99 ---- >ACCEPTABLE 35.0 9.836E+08 13176. 8.62 ---- >ACCEPTABLE 40.0 9.381E+08 12566. 8.25 ---- >ACCEPTABLE 45.0 8.914E+08 11940. 7.86 ---- >ACCEPTABLE 50.0 8.438E+08 11304. 7.47 ---- >ACCEPTABLE 55.0 7.959E+08 10662. 7.07 ---- >ACCEPTABLE 60.0 7 .479E+08 10018. 6.67 ---- >ACCEPTABLE 65.0 7.001E+08 9379. 6.28 ---- >ACCEPTABLE 70.0 6.198E+08 8303. 5.62 ---->ACCEPTABLE 75.0 6.084E+08 8151. 5.52 ---- >ACCEPTABLE 80.0 5.494E+08 7359. 5.04 ---->ACCEPTABLE 85.0 4.923E+08 6595. 4.56 ---- >ACCEPTABLE 90.0 4.890E+08 6551. 4.54 ---- >ACCEPTABLE 95.0 4.357E+08 5837. 4.10 ---- >ACCEPTABLE 100.0 3.837E+08 5140. 3.67 ---->ACCEPTABLE 105.0 3.504E+08 4694. 3.39 ---- >ACCEPTABLE 110.0 3.362E+08 4504. 3.27 ---- >ACCEPTABLE

115.0 3.241E+08 4341. 3.17 ---- >ACCEPTABLE 120.0 2.634E+08 3529. 2. 67 ---- >ACCEPTABLE 125.0 2.583E+08 3461. 2.63 ---->ACCEPTABLE 130.0 2.417E+08 3238. 2.49 ---->ACCEPTABLE 135.0 2.472E+08 3311. 2.54 ---->ACCEPTABLE 140.0 2.245E+08 3008. 2.35 ---->ACCEPTABLE 145.0 2.067E+08 2769. 2.20 ---->ACCEPTABLE 150.0 2.448E+08 3279. 2.52 ---- >ACCEPTABLE 155.0 2.355E+08 3154. 2.44 ---- >ACCEPTABLE 160.0 2.635E+08 3530. 2.67 ---->ACCEPTABLE 165.0 2.599E+08 3482. 2.64 ---- -ACCEPTABLE 170.0 2.751E+08 3694. 2.78 ---- >ACCEPTABLE 175.0 2.94.30E408 3938. 2.93 ---- >ACCEPTABLE 180.0 2.825E+08 3784. 2.83 ---- >ACCEPTABLE 185.0 3.633E+08 4867. 3.50 ---- >ACCEPTABLE 190.0 3.970E+08 5318. 3.78 --- ->ACCEPTABLE 195.0 4.328E+08 5797. 4.07 ---- >ACCEPTABLE 200.0 4.702E+08 6299. 4.38 ---- >ACCEPTABLE 205.0 5.091E+08 6819. 4.70 ---- ACEPTABLE 210.0 5. 490E+08 7354. 5.03 ---->ACCEPTABLE 215.0 5.901E+08 7905. 5.37 ---- >ACCEPTABLE 220.0 6.002E+08 8041. 5.46 ---- >ACCEPTABLE 225.0 6.799E+08 9108. 6.11 ---- >ACCEPTABLE 230.0 7.274E+08 9745. 6.51 ---- >ACCEPTABLE 235.0 7.754E+08 10387. 6.90 ---- >ACCEPTABLE 240.0 8.234E+08 11030. 7.30 ---- >ACCEPTABLE 245.0 8.711E+08 11670. 7.69 ---- >ACCEPTABLE 250.0 9.182E+08 12300. 8.08 ---- >ACCEPTABLE 255.0 9.486E+08 12707. 8.33 ---- >ACCEPTABLE 260.0 9.786E+08 13109. 8.58 ---- >ACCEPTABLE 265.0 1.041E+09 13946. 9.10 ---- >ACCEPTABLE 270.0 1.084E+09 14515. 9.45 ---- >ACCEPTABLE 275.0 1.123E+09 15041. 9.77 ---- >ACCEPTABLE 280.0 1.158E+09 15518. 10.07 ---- >ACCEPTABLE 285.0 1.190E+09 15944. 10.33 ---- >ACCEPTABLE 290.0 1.218E+09 16315. 10.56 ---- >ACCEPTABLE 295.0 1.225E+09 16412. 10.62 ---- >ACCEPTABLE 300.0 1.264E+09 1692 9. 10.94 ---- >ACCEPTABLE 305.0 1.300E+09 17408. 11.23 ---- >ACCEPTABLE 310.0 1.315E+09 17613. 11.36 ---- >ACCEPTABLE 315.0 1. 326E+09 17164. 11.45 ---- >ACCEPTABLE 320.0 1.333E+09 17860. 11.51 ---- >ACCEPTABLE 325.0 1.336E+09 17900. 11.53 ---- >ACCEPTABLE 330.0 1.335E+09 17884. 11.52 ---- >ACCEPTABLE 335.0 1.330E+09 17811. 11.48 ---- >ACCEPTABLE 340.0 1.320E+09 17684. 11.40 ---- >ACCEPTABLE 345.0 1.307E+09 17502. 11.29 ---- >ACCEPTABLE 350.0 1 .289E+09 17267. 11.14 ---- >ACCEPTABLE 355.0 1.268E+09 16980. 10.97 ---- >ACCEPTABLE ACCEPTABLE! MINTMUM SAFETY FACTOR - 2.20 AT 145.0 DEGREES.

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/16/2002

SUMMARY

OF INPUTS:

Title:

Limerick 2 H EOC10 NU LLR Angle increment - 1.0 deg. (4[COARSE)

Membrane Stress, Pm = 335. psi Bending Stress, Pb = 483. psi Safety Factor, SF - 2.77 Mean Radius, Rm - 109.00 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm - 14400. psi Fluence - O.OE*00 n/cm^2 (Thus, LEFM evaluation not applicable)

THETAI THETA2 THICKNESS REGION (deg. I (deg.] [inches) 1 2.3 9.5 2.000 2 161.9 203. 4 2.000 3 233.8 235.9 1.990 4 246.8 259.3 2.000 5 283.2 291.8 2.000 LIMIT LOAD RESULTS:

, -s NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY (deg) lin-lbs] Ipsi] FACTOR RESULT

________ ___C_____T_____

.0 1.308E+09 17525. 21.83 ---->ACCEPTABLE 5.0 1.280E+09 17143. 21.37 ---->ACCEPTABLE 10.0 1.248E+09 16717. 20.85 ---->ACCEPTABLE 15.0 1.213E+09 16251. 20.28 ---->ACCEPTABLE 20.0 1.176E+09 15748. 19.66 ---->ACCEPTABLE 25.0 1.136E+09 15211. 19.01 ---->ACCEPTABLE 30.0 1.093E+09 14646. 18.31 ---->ACCEPTABLE 35.0 1.049E+09 14056. 17.59 ---- >ACCEPTABLE 40.0 1.004E+09 13446. 16.85 ---->ACCEPTABLE 45.0 9.571E+08 12821. 16.08 ---->ACCEPTABLE 50.0 9.096E+08 12184. 15.30 ---- >ACCEPTABLE 55.0 8.616E+08 11542. 14.52 ---- >ACCEPTABLE 60.0 8.136E+08 10899. 13.73 ---- >ACCEPTABLE 65.0 7.659E+08 10259. 12.95 ---- >ACCEPTABLE 70.0 7.193E+08 9635. 12.19 ---->ACCEPTABLE 75.0 6.587E+08 8824. 11.20 ---->ACCEPTABLE 80.0 6.002E+08 8041. 10.24 ---->ACCEPTABLE 85.0 5.949E+08 7970. 10.15 ---- >ACCEPTABLE 90.0 5.407E+08 7243. 9.26 ---- >ACCEPTABLE 95.0 4.879E+08 6536. 8.40 ---- >ACCEPTABLE 100.0 4.887E+08 6547. 8.41 ---- >ACCEPTABLE 105.0 4.553E+08 6099. 7.87 ---- >ACCEPTABLE 110.0 3.883E+08 5202. 6.77 ---- >ACCEPTABLE

115.0 3.757E+08 5033. 6.56 ---- >ACCEPTABLE 120.0 3.659E+08 4901. 6.40 ---- >ACCEPTABLE 125.0 3.260E+08 436 7. 5.75 ---->ACCEPTABLE 130.0 2.921E+08 3914. 5.19 ---->ACCEPTABLE 135.0 3.136E+08 4202. 5.55 ---->ACCEPTABLE 140.0 2.751E+08 3685. 4.91 ---->ACCEPTABLE 145. 0 3. 087E+08 4135. 5.46 ---->ACCEPTABLE 150.0 2.963E+08 3969. 5.26 ---->ACCEPTABLE 155.0 3. 045E+08 4079. 5.40 ---- >ACCEPTABLE 160.0 3.151E+08 4221. 5.57 ---- >ACCEPTABLE 165.0 3.287E+08 4403. .79 ---- >ACCEPTABLE 170.0 3.444E+08 4614. 6.05 ---- >A.CCEPTABLE 175.0 3.453E+08 4626. 6.06 ---->ACCEPTABLE 180.0 3.510E+08 4702. 6.16 ---- >ACCEPTABLE 185.0 4.144E+08 5551. 7.20 ---->ACCEPTABLE 190.0 4. 645E+08 6223. 8.02 ---- >ACCEPTABLE 195.0 5.003E+08 6702. 8.60 ---- >ACCEPTABLE 200.0 5.378E+08 7204. 9.22 ---- >ACCEPTABLE ZZ)5. 0 5.7 66E+08 7724. 9.85 ---- >ACCEPTABLE

. . 6.165E+08 8259. 10.51 ---- >ACCEPTABLE 215.0 6.406E+08 8581. 10.90 ---- >ACCEPTABLE 220.0 7. 001E+08 9379. 11.87 ---- >ACCEPTABLE 225.0 7.129E+08 9550. 12.08 ---- >ACCEPTABLE 230.0 7.932E+08 10625. 13.40 ---- >ACCEPTABLE 235.0 8.411E+08 11267. 14.18 ---- >ACCEPTABLE 240.0 8.891E+08 11911. 14.97 ---- >ACCEPTABLE 245.0 9.369E+08 12550. 15.75 ---- >ACCEPTABLE 250.0 9.678E+08 12964. 16.26 ---- >ACCEPTABLE 255.0 9.988E+08 13380. 16.77 ---- >ACCEPTABLE 260.0 1.063E+09 14241. 17.82 ---- >ACCEPTABLE 265.0 1.109E+09 14851. 18.56 ---- >ACCEPTABLE 270.0 1.151E+09 15420. 19.26 ---- >ACCEPTABLE 275.0 1.190E+09 15946. 19.90 ---- >ACCEPTABLE 280.0 1.226E+09 16423. 20.49 ---- >ACCEPTABLE 285.0 1.258E+09 16849. 21.01 ---- >ACCEPTABLE 290.0 1.285E+09 17219. 21.46 ---- >ACCEPTABLE 295.0 1.326E+09 17759. 22.12 ---- >ACCEPTABLE 300.0 1.314E+09 17596. 21.92 ---- >ACCEPTABLE 305.0 1.365E+09 18288. 22.77 ---- >ACCEPTABLE 310.0 1.381E+09 18493. 23.02 ---- >ACCEPTABLE 315.0 1.392E+09 18644. 23.20 ---- >ACCEPTABLE 320.0 1.399E+09 18740. 23.32 ---- >ACCEPTABLE 325.0 1.402E09 18780. 23.37 ---- >ACCEPTABLE 330.0 1.401E+09 18764. 23.35 ---- >ACCEPTABLE 335.0 1.395E+09 18692. 23.26 ---- >ACCEPTABLE 340.0 1.386E+09 18564. 23.10 ---- >ACCEPTABLE 345.0 1.372E+09 18382. 22.88 ---- >ACCEPTABLE 350.0 1.355E+09 18147. 22.59 ---- >ACCEPTABLE 355.0 1.333E+09 17861. 22.24 ---- >ACCEPTABLE ACCEPTABLE! MINIMUM SAFETY FACTOR 4 4.91 AT 140.0 DEGREES.

GENE 0000-0006 2 250-04a, Rev. 0 APPENDIX C-STRUCTURAL MARGIN CALCULATIONS FOR H2 18

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/19/2002

SUMMARY

OF INPUTS:

===ssn===ss^C=J

Title:

Limerick 2 H2 EOC1O EF LLR Angle increment - 1.0 deg. (COARSE)

Membrane Stress, Pm = 808. psi Bending Stress, Pb - 1090. psi Safety Factor, SF = 1.39 Mean Radius, Rm - 109.00 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm = 14400. psi Fluence = 0.OE+00 n/cm^2 (Thus, LEFM evaluation not applicable)

THET'A: L THETA2 THICKNESS REGION [deg I [deg.] [inches]

I .0 360.0 .540 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKJ E COMPRESSION.

ALPHiA MOMENT Pb' SAFETY

[deg] [in-lbs) [psi] FACTOR RESULT 11.11_ ----- ________

.0 20282. 11.11 ---- >ACCEPTABLE 1 .514E+09 20282.

5.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

10.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

15.0 11.11 >ACCEPTABLE 1 .514E409 20282.

20.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

25.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

30.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

35.0 11.11 ---- >ACCEPTABLE 1 .514E+09 20282.

40.0 11.11 ---- >ACCEPTABLE 1.514E.09 20282.

45.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

50.0 11.11 ---- >ACCEPTABLE 1 .514E+09 20282.

55.0 11.11 ---- >ACCEPTABLE 1 .514E.09 20282.

60.0 11.11 ---- >ACCEPTABLE 1 .514E+09 20282.

65.0 11.11 ---- >ACCEPTABLE 1 .514E+09 20282.

70.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

75.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

80.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

85.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

90.0 11.11 ---- >ACCEPTABLE 1 .51 4E+ 09 20282.

95.0 11.11 ---- >ACCEPTABLE 1.5 14E+09 20282.

100.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

105.0 11.11 ---- >ACCEPTABLE 1.514E+09 20282.

110.0 11.11 ----- >ACCEPTABLE 115.0 1.5 14E+09 20282. 11.11 ---- >ACCEPTABLE 120.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 125.0 1. 514E+09 20282. 11.11 ---- >ACCEPTABLE 130.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE

135.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 140.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 145 .0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 150.0 1.514E+09 20282. 11.11 -- >ACCEPTABLE 155.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 160.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 165.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 170.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 175.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 180.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 185.0 1.514E+09 20282. 11.11 190.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 195.0 1.514E+09 20282. 11.11 200.0 1.514E+09 20282. 11.11 ->ACCEPTABLE 205.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 210.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 215.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 220.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 225.0 1.514E+Cn 20232. 11.11 ---- >ACCEPTABLE 230.0 1.514E+09 20282. 11.11 --- >ACCEPTABLE 235.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 240.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 245.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 250.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 255.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 260.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 265.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 270.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 275.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 280.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 285.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 290.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 295.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 300.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 305.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 310.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 315.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 320.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 325.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 330.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 335.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 340.0 1.514E+09 20282. 11.11 ---->ACCEPTABLE 345.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE 350.0 1.514E+09 20282. 11.11 ---- >ACCEPTABLE


>ACCEPTABLE 355.0 1.514E+09 20282. 11.11 ACCEPTABLE! MINIMUM SAFETY FACTOR = 11.11 AT 255.0 DEGREES.

l DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/19/2002

SUMMARY

OF INPUTS:

Title:

Limerick 2 H2 EOCIO NU LLR Angle increment - 1.0 deg. (COARSE)

Membrane Stress, Pm = 335. psi Bending Stress, Pb = 652. psi Safety Factor, SF - 2.77 Mean Radius, Rm - 109.00 inches Wall Thickness, t 2.000 in-hes

_;ress Intensity, Sm = 14400. psi Fluence - 0.OE+00 n/cm^2 (Thus, LEFM evaluation not applicable)

THET'Al THETA2 THIlCKNESS REGION [deg . I [deg. ] [inches]

1 .0 360.0 .540 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY

[deg] (in-lbs] [psi] FACTOR RESULT


AC______L_

.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 5.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 10.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 15.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 20.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 25.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 30.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 35.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 40.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 45.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 50.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 55.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 60.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 65.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 70.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 75.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 80.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 85.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 90.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 95.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 100.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 105.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 110.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 115.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 120.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 125.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 130.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE

135.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 140.0 1. 551E+09 20775. 21.39 ---->ACCEPTABLE 145.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 150.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 155.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 160.0 1.551E+09 20775. 21.39 ---->ACCEPTAELE 165.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 170.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 175.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 180.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 185.0 1.551E+09 20775. 21.39 ---- >ACCEPTABLE 190. 0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 195.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 200.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 205.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 210.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 215.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 220.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 225.0 1.551E+09 2 U175. 21.39 ---->ACCEPTAELE 230.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 235.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 240.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 245.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 250.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 255.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 260.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 265.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 270.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 275.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 280.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 285.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 290.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 295.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 300.0 1.551E+09 20775. 21 .39 ---->ACCEPTABLE 305.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 310.0 1.551E+09 20775. 21 .39 ---->ACCEPTABLE 315.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 320.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 325.0 1.551E+09 20775. 21 .39 ---->ACCEPTABLE 330.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 335.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 340.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 345.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 350.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE 355.0 1.551E+09 20775. 21.39 ---->ACCEPTABLE ACCEPTABLE! MINIMUM SAFETY FACTOR- 21.39 AT 255.0 DEGREES.

GENE 0000-00 0 6 - 22 50-04a, Rep. O APPENDIX D-STRUCTURAL MARGIN CALCULATIONS FOR H3 19

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/20/2002

SUMMARY

OF INPUTS:

S flflfl-------l

Title:

Limerick 2 H3 EOC10 EF LLR Angle increment = 1.0 deg. (COARSE)

Membrane Stress, E?m = 859. psi Bending Stress, PhI 1259. psi Safety Factor, SF - 1.39 Mean Radius, Rm - 102.56 inches Wall Thickness, t 2.000 inches Stress Intensity, Sm = 14400. psi Fluence - 0.0E+00 n/cm'2 (Thus, LEFM evaluation not applicable)

THETAI THETA2 THICKNESS REGION [deg.3 (deg.) [inches)

.43____0 1 29.5 37.8 .430 2 52.1 58.0 .430 3 85.9 94.4 .430 4 94.4 96.8 2.000 5 96.8 102.9 .560 6 120.5 122.1 1.990 7 122.1 127.4 .550 8 178.1 181.7 .650 9 181.7 183.7 1.990 10 183.7 185.4 .730 11 209.5 211.1 .490 12 264.9 288.4 .490 13 301.5 307.6 .490 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY

[deg) fin-lbsl (psi) FACTOR RESULT

______ ---- AC_____L_

.0 1.754E+08 2654. 1.66 ---- >ACCEPTABLE 5.0 1. 917E+08 2900. 1.77 ---- >ACCEPTABLE 10.0 1.800E+08 2724. 1.69 >ACCEPTABLE 15.0 1.681E+08 2543. 1.61 ---- >ACCEPTABLE 20.0 1.793E+08 2713. 1.69 ---- >ACCEPTABLE 25.0 1.614E+08 2442. 1.56 >ACCEPTABLE 30.0 1.571E+08 2377. 1.53 >ACCEPTABLE 35.0 1.646E+08 2490. 1.58 >ACCEPTABLE 40.0 1.595E+0 2413. 1.54 >ACCEPTABLE 45.0 1.734E+08 2623. 1.64 ---- >ACCEPTABLE 50.0 1.736E+08 2627. 1.65 ---- >ACCEPTABLE 55.0 1.743E+08 2638. 1.65 ---- >ACCEPTABLE 60.0 1.756E+08 2656. 1.66 ---- >ACCEPTABLE 65.0 1.773E+08 2682. 1.67 ---- >ACCEPTABLE 70.0 1.794E+08 2714. 1.69 ---- >ACCEPTABLE

I 75.0 1.820E+08 2753. 1.71 ---->ACCEPTABLE 80.0 1.850E+08 2799. 1.73 ---->ACCEPTABLE 85.0 1.723E+08 2607. 1.64 ---->ACCEPTABLE 90.0 1.877E+08 2840. 1.75 ---->ACCEPTABLE 95.0 1.866E+08 2823. 1.74 ---- >ACCEPTABLE 100.0 1.807E+08 2735. 1.70 ---- >ACCEPTABLE 105.0 2.054E+08 3108. 1.87 ---- >ACCEPTABLE 110.0 2.104E+08 3183. 1.91 ---->ACCEPTABLE 115.0 2.232E+08 3378. 2.00 ---->ACCEPTABLE 120.0 2.286E+08 3459. 2.04 ---->ACCEPTABLE 125.0 2.340E+08 3541. 2.08 ---->ACCEPTABLE 130.0 2.318E+08 3507. 2.06 ---- %ZsCEPTABLE 135.0 2.374E+08 3591. 2.10 ---- >ACCEPTABLE 140.0 2. 429E+08 3676. 2.14 ---->ACCEPTABLE 145.0 2.484E+08 3759. 2.18 ---->ACCEPTABLE 150.0 2.539E+08 3842. 2.22 ---- >ACCEPTABLE 155.0 2.592E+08 3922. 2.26 ---- >ACCEPTABLE 160.0 2. 643E+08 4000. 2.29 ---- >ACCEPTABLE 165.0 4074. 2.33 ---- >ACCEPTABLE 170.0 2.856E+08 4321. 2.45 ---->ACCEPTABLE 175.0 2.741E+08 4147. 2.36 ---- >ACCEPTABLE 180.0 2.976E+08 4502. 2.53 ---- >ACCEPTABLE 185.0 2. 659E+08 4023. 2.31 ---- >ACCEPTABLE 190.0 2.693E+08 4074. 2.33 ---- >ACCEPTABLE 195.0 2.999E+08 4538. 2.55 ---- >ACCEPTABLE 200.0 2.831E+08 4283. 2.43 ---- >ACCEPTABLE 205.0 3.050E+08 4615. 2.58 ---- >ACCEPTABLE 210.0 2.869E+08 4341. 2.46 ---- >ACCEPTABLE 215.0 2.920E+08 4418. 2.49 ---- >ACCEPTABLE 220. 0 2.849E+08 4311. 2.44 ---- >ACCEPTABLE 225.0 3.011E+08 4556. 2.56 ---- >ACCEPTABLE 230.0 3.009E+08 4552. 2.55 ---- >ACCEPTABLE 235.0 3.001E+08 4541. 2.55 ---- >ACCEPTABLE 240.0 2.989E+08 4523. 2.54 ---- >ACCEPTABLE 245.0 2.972E+08 4497. 2.53 ---- >ACCEPTABLE 250.0 2.951E+08 4465. 2.51 ---- >ACCEPTABLE 255.0 2.925E+08 4426. 2.50 ---->ACCEPTABLE 260.0 2.895E+08 4380. 2.47 ---- >ACCEPTABLE 265.0 2.861E+08 4329. 2.45 ---- >ACCEPTABLE 270.0 2. 823E+08 4272. 2.42 ---->ACCEPTABLE 275.0 2.782E+08 4210. 2.39 ---- >ACCEPTABLE 280.0 2.738E+08 4143. 2.36 ---- >ACCEPTABLE 285.0 2.691E+08 4071. 2.33 ---- >ACCEPTABLE 290.0 2. 641E+08 3996. 2.29 ---- >ACCEPTABLE 295.0 2.692E+08 4073. 2.33 ---- >ACCEPTABLE 300.0 2.460E+08 3722. 2.16 ---- >ACCEPTABLE 305.0 2. 44 OE+08 3692. 2.15 ----->ACCEPTABLE 310.0 2.248E+08 3401. 2.01 ---- >ACCEPTABLE 315.0 2.371E+08 3588. 2.10 ---- >ACCEPTABLE 320.0 2.137E+08 3233. 1.93 ---- >ACCEPTABLE 325.0 2.116E+08 3202. 1. 92 ---- >ACCEPTABLE 330.0 2.027E+08 3067. 1.85 ---- >ACCEPTABLE 335.0 2.153E+08 3257. 1.94 ---- >ACCEPTABLE 340.0 2.101E+08 3180. 1.91 ---- >ACCEPTABLE 345.0 2.052E+08 3105. 1.87 ---- >ACCEPTABLE 350.0 2.073E+08 3136. 1.89 355.0 1.850E+08 2800. 1.73 ---- >ACCEPTABLE

ACCEPTABLE! MINIMUM SAFETY FACTOR = 1.53 AT 30.0 DEGREES.

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/20/2002

SUMMARY

OF INPUTS:

==_,fl. fl__-__

Title:

Limerick 2 H3 EOC1C NU LLR Angle increment - 1.0 deg. (COARSE)

Membrane Stress, Pm = 356. psi Bending Stress, Pb - 754. psi.

Safety Factor, SF - 2.77 Mean Radius, Rn - 102.56 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm - 14400. psi Fluence - O.OE+00 n/cm'2 (Thus, LEFM evaluation not applicable)

THETAl THETA2 THICKNESS REGION Ideg. I Ideg.] [inches]

_.430 ___

1 29.5 37.8 .430 2 52.1 58.0 .430 3 85.9 94.4 .430 4 94.4 96.8 2.000 5 96.8 102.9 .560 6 120.5 122.1 1.990 7 122.1 127. 4 .550 8 178.1 181.7 .650 9 181.7 183.7 1.990 10 183.7 185.4 .730 11 209.5 211.1 .490 12 264 .9 288.4 .490 13 301.5 307.6 .490 LIMIT LOAD RESULTS:

Wa.=s=-=-as----sa-NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT PbI SAFETY

[deg] [in-lbs) [psi] FACTOR RESULT 5.0 2.587E+08 3914. 3.85 >ACCEPTABLE 5.0 2.703E+08 4090. 4.01 ---- >ACCEPTABLE 10.0 2.498E+08 3780. 3.73 ---- >ACCEPTABLE 15.0 2.398E+08 3628. 3.59 ---- >ACCEPTABLE 20.0 2.508E+08 3795. 3.74 ---- >ACCEPTABLE 25.0 2.443E+08 3696. 3.65 ---- >ACCEPTABLE 30.0 2.288E+08 3462. 3.44 ---- >ACCEPTABLE 35.0 2.276E+08 3444. 3.42 ---- >ACCEPTABLE 40.0 2.423E+08 3666. 3.62 ---- >ACCEPTABLE 45.0 2.447E+08 3703. 3.66 ---- >ACCEPTABLE 50.0 2.364E+08 3576. 3.54 ---- >ACCEPTABLE 55.0 2.371E+08 3587. 3.55 ---- >ACCEPTABLE 60.0 2.383E+08 3606. 3.57 ---- >ACCEPTABLE 65.0 2.400E+08 3631. 3.59 ---- >ACCEPTABLE 70.0 2.421E+08 3664. 3.62 ---- >ACCEPTABLE

75.0 2.447E+08 3703. 3.66 ---- >ACCEPTABLE 80.0 2.528E+08 3825. 3.77 ---- >ACCEPTABLE 85.0 2.665E+08 4033. 3.95 ---- >ACCEPTABLE 90.0 2.507E+08 3793. 3.74 ---- >ACCEPTABLE 95.0 2.548E+08 3855. 3.79 ---- >ACCEPTABLE 100.0 2.749E+08 4159. 4.07 ---- >ACCEPTABLE 105.0 2. 681E+08 4057. 3.98 ---- >ACCEPTABLE 110.0 2.731E+08 4132. 4.04 ---- >ACCEPTABLE 115.0 2.860E+08 4327. 4 .22 ---- >ACCEPTABLE 120.0 2.913E+08 4408. 4.29 --- >ACCEPTABLE 125.0 2.968E+08 4490. 4.37 ---->ACCTTA8LE 130.0 2. 984E+08 4515. 4.39 ---->ACCEPTA'BLE 135.0 3.001lE+08 4541. 4.41 140.0 3.057E+08 4625. 4.49 ---- >ACCEPTABLE 145.0 3.112E+08 4709. 4.56 ---- >ACCEPTABLE 150.0 3.166E+08 47 91. 4.64 ---- >ACCEPTABLE 155.0 3.219E+08 4871. 4.71 ---- >ACCEPTABLE 160.0 3.271E+08 4949. 4.78 ---- >ACCEPTABLE 165.0 3.320E+08 5024. 4 .8 ---- >ACCEPTABLE 170.0 3.208E+08 4855. 4.69 ---- >ACCEPTABLE 175.0 3.447E+08 5215. 5.02 ---- >ACCEPTABLE 180. 3.329E+08 5037. 4 .86 ---- >ACCEPTABLE 185.0 3.444E+08 5211. 5.02 ---->ACCEPTABLE 190.0 3.478E+08 5262. 5.06 ---->ACCEPTABLE 195.0 3.705E+08 5606. 5.37 ---->ACCEPTABLE 200.0 3.537E+08 5351. 5.14 ---->ACCEPTABLE 205.0 3.441E+08 5207. 5.01 ---->ACCEPTABLE 210.0 3.536E+08 5351. 5.14 ---->ACCEPTABLE 215.0 3.549E+08 5370. 5.16 ---- >ACCEPTABLE 220.0 3.555E+08 5379. 5.17 ---->ACCEPTABLE 225.0 3.715E+08 5622. 5.39 ---->ACCEPTABLE 230.0 3.636E+08 5502. 5.28 ---->ACCEPTABLE 235.0 3.629E+08 5491. 5.27 --- ->ACCEPTABLE 240.0 3. 617E+08 5472. 5.25 ---- >ACCEPTABLE 245.0 3. 600E+08 5447. 5.23 ---->ACCEPTABLE 250.0 3.578E+08 5414. 5.20 ---->ACCEPTABLE 255.0 3.552E+08 5375. 5.16 ---->ACCEPTABLE 260.0 3.522E+08 5330. 5.12 ---- >ACCEPTABLE 265.0 3.488E+08 5278. 5.08 ---->ACCEPTABLE 270.0 3.451E+08 5221. 5.02 ---->ACCEPTABLE 275.0 3.410E+08 5159'. 4.97 ---->ACCEPTABLE 280.0 3.365E+08 5092. 4 .91 ---->ACCEPTABLE 285.0 3.318E+08 5021. 4.84 ---->ACCEPTABLE 290.0 3.269E+08 4946. 4.78 ---- >ACCEPTABLE 295.0 3.387E+08 5124. 4 .94 ---->ACCEPTABLE 300.0 3.123E+08 4725. 4.58 ---->ACCEPTABLE 305.0 3.069E+08 4643. 4.50 ---->ACCEPTABLE 310.0 2.944E+08 4455. 4.33 ---->ACCEPTABLE 315.0 3.134E+08 4741. 4.59 ---->ACCEPTABLE 320.0 3.113E+08 4710. 4.56 ---->ACCEPTABLE 325.0 3.058E+08 4627. 4.49 ---->ACCEPTABLE 330.0 3.003E+0 4544. 4.41 ---- >ACCEPTABLE 335.0 2.848E+08 4309. 4.20 ---- >ACCEPTABLE 340.0 2.729E+08 4129. 4.04 ---->ACCEPTABLE 345.0 2.679E+08 4054. 3.97 ---->ACCEPTABLE 350.0 2.768E+08 4188. 4.09 ---- >ACCEPTABLE 355.0 2.547E+08 3854. ---- >ACCEPTABLE 3.79

I I ACCEPTABLE! MINIMUM SAFETY FACTOR 3.42 AT 35.0 DEGREES.

GENE 0000-0006-2250-04a,Rev. 0 APPENDIX E-STRUCTURAL MARGIN CALCULATIONS FOR H4 20

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/03/2002

SUMMARY

OF INPUTS:

=,.,.== ---- =.= =-

Title:

Limerick 2 H4 EOC10 EF LLR Angle increment = 1.0 deg. (COARSE)

Membrane Stress, Pm = 859. psi Bending Stress, Pb 5 1986. psi Safety Factor, SF - 1.39 Mean Radius, Rm - 102.56 inches Wall Thickness, t - 2.000 inches Stress Intensity Sm - 14400. psi Fluence - Q.OE+00 n/cm'2 (Thus, LEFM evaluation not applicable)

THETAl THETA2 THICKNESS REGION Ideg. I [deg.] [inches)

.0 2.8 .720 2 2.8 5.1 2.000 3 5.1 11.5 .710 4 78.5 79.4 .710 5 79.4 83.9 2.000 6 83.9 101.5 .720 7 168.5 181.2 .720 8 181.2 183.3 2.000 9 183.3 191.5 .720 10 258.5 266.0 .720 11 266.0 278.0 2.000 12 278.0 281.5 .720 13 348.5 360.0 .720 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY

[deg) jin-lbs) [psi] FACTOR RESULT

.0 6.651E+08 10064. 3.84 ---- >ACCEPTABLE 5.0 6.292E+08 9520. 3.65 ---->ACCEPTABLE 10.0 6.542E+08 9898. 3.78 ---- >ACCEPTABLE 15.0 6.619E+08 10015. 3.82 ---->ACCEPTABLE 20.0 6.333E+08 9582. 3.67 ---->ACCEPTABLE 25.0 6.402E+08 9687. 3.71 ---->ACCEPTABLE 30.0 6.471E+08 9791. 3.74 ---->ACCEPTABLE 35.0 6.452E+08 9762. 3.73 ---->ACCEPTABLE 40.0 6.428E+08 9725. 3.72 ---->ACCEPTABLE 45.0 6.398E+08 9681. 3.70 ---- >ACCEPTABLE 50.0 6.364E+08 9629. 3.69 ---->ACCEPTABLE 55.0 6.325E+08 9571. 3.67 ---->ACCEPTABLE 60.0 6.283E+08 9506. 3.64 ---->ACCEPTABLE 65.0 6.155E+08 9312. 3.58 ---->ACCEPTABLE 70.0 6.027E+08 9119. 3.51 ---->ACCEPTABLE

75.0 6.257E+08 9468. 3.63 ---- >ACCEPTABLE 80.0 5.963E+08 9023. 3.47 ---->ACCEPTABLE 85.0 6.192E+08 9369. 3.60 ---->ACCEPTABLE 90.0 5. 939E+08 8987. 3.46 ---->ACCEPTABLE 95.0 6.069E+08 9183. 3.53 ---->ACCEPTABLE 100.0 5.720E+08 8654. 3.34 ---->ACCEPTABLE 105.0 5.729E+08 8668. 3.35 ---->ACCEPTABLE 110. 0 5 .544E+08 8388. 3.25 ---->ACCEPTABLE 115.0 5.559E+08 8411. 3.26 --- >ACCEPTABLE 120.0 5.579E+08 8442. 3.27 ---->ACCEPTABLE 125.0 5.518E+08 8350. 3.24 ---->ACCEPTABLE 130.0 5.460E+08 8261. 3.21 ---->ACCEPTABLE 135.0 5.403E+08 8176. 3.18 ---->ACCEPTABLE 140.0 5.350E+08 8095. 3.15 --- >ACCEPTABLE 145.0 5.299E+08 8018. 3.12 ---- >ACCEPTABLE 150.0 5.252E+08 7947. 3.10 --- >ACCEPTABLE 155.0 5.128E+08 7760. 3.03 ---- >ACCEPTABLE 160.0 5.012E+08 7584. 2.97 ---->ACCEPTABLE 165.0 5.298E+08 8016. 3.12 - --- >.CPTABLE 170.0 5.134E+08 7768. 3.03 --- >ACCEPTABLE 175.0 4.971E+08 7521. 2. 95 ---- >ACCEPTABLE 180.0 4.916E+08 7438. 2.92 ---- >ACCEPTABLE 185.0 5.041E+08 7628. 2.98 --- >ACCEPTABLE 190.0 5.005E+08 7574. 2.96 --- >ACCEPTABLE 195.0 5.137E+08 7772. 3.03 ---- >ACCEPTABLE 200.0 4.816E+08 7288. 2.86 ---- >ACCEPTABLE 205.0 4.968E+08 7516. 2.94 ---- >ACCEPTABLE 210.0 5.063E+08 7662. 2.99 ---- >ACCEPTABLE 215.0 5.083E+08 7690. 3.01 ---->ACCEPTABLE 220.0 5.107E+08 7727. 3.02 ---->ACCEPTABLE 225.0 5.136E+08 7771. 3.03 ---- ;ACCEPTABLE 230.0 5.170E+08 7823. 3.05 --- >ACCEPTABLE 235.0 5.209E+08 7882. 3.07 ---- >ACCEPTABLE 240.0 5.252E+08 7947. 3.10 ---- >ACCEPTABLE 245.0 5.218E+08 7895. 3.08 ---- >ACCEPTABLE 250.0 5.191E+08 7854. 3.06 --- >ACCEPTABLE 255.0 5.528E+08 8365. 3.24 ---- >ACCEPTABLE 260.0 5.346E+08 8089. 3.15 ---- >ACCEPTABLE 265.0 5.427E+08 8212. 3.19 ---- >ACCEPTABLE 270.0 5.658E+08 8561. 3.31 ---- >ACCEPTABLE 275.0 5.549E+08 8397. 3.25 ---- >ACCEPTABLE 280.0 5.689E+08 8607. 3.33 ---- >ACCEPTABLE 285.0 5.824E+08 8812. 3.40 ---- >ACCEPTABLE 290.0 5.861E+08 8868. 3.42 ---->ACCEPTABLE 295.0 5.808E+08 8788. 3.39 ---- >ACCEPTABLE 300.0 5.955E+08 9011. 3.47 ---->ACCEPTABLE 305.0 6.016E+08 9103. 3.50 ---->ACCEPTABLE 310.0 6.075E+08 9192. 3.53 ---- >ACCEPTABLE 315.0 6.131E+08 9277. 3.56 ---- >ACCEPTABLE 320.0 6.185E+08 9358. 3.59 ---- >ACCEPTABLE 325.0 6.235E+08 9434. 3.62 ---->ACCEPTABLE 330.0 6.282E+08 9505. 3.64 ---->ACCEPTABLE 335.0 6.081E+08 9201. 3.54 ---->ACCEPTABLE 340.0 6.243E+08 9446. 3.62 ---->ACCEPTABLE 345.0 6.566E+08 9936. 3.79 ---->ACCEPTABLE 350.0 6.522E+08 9868. 3.77 ---->ACCEPTABLE 355.0 6.466E+08 9784. 3.74 ---- >ACCEPTABLE

ACCEPTABLE! MINIMUM SAFETY FACTOR - 2.86 AT 200.0 DEGREES.

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 09/03/2002

SUMMARY

OF INPUTS:

Title:

Limerick 2 H4 EOC10 NU LLR Angle increment - 1.0 deg. (COARSE)

Membrane Stress, Pm = 356. psi Bending Stress, Pb - 1166. psi Safety Factor, SF = 2.77 Mean Radius, Rm = 102.56 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm - 14400. psi Fluence - 0.OE+00 n/cm^2 (Thus, LEFM evaluation not applicable)

THETAI THETA2 THICKNESS REGION [deg.] [deg.) [inches]

1 .0 2.8 .720 2 2.8 5.1 2.000 3 5.1 11.5 .710 4 78.5 79.4 .710 5 79.4 83.9 2.000 6 83.9 101.5 .720 7 168.5 181.2 .720 8 181.2 163.3 2.000 9 183.3 191.5 .720 10 258.5 266.0 .720 266.0 278.0 2.000 12 278.0 281.5 .720 13 348.5 360.0 .720 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY Ideg] [in-lbs] [psi] FACTOR RESULT


___T_B__

.0 7.265E+08 10993. 7.46 ---->ACCEPTABLE 5.0 7.212E+08 10913. 7.40 ---->ACCEPTABLE 10.0 6.901E+08 10442. 7.09 ---->ACCEPTABLE 15.0 6.977E+08 10556. 7.17 ---->ACCEPTABLE 20.0 7.046E+08 10662. 7.24 ---->ACCEPTABLE 25.0 7.112E+08 10761. 7.30 ---->ACCEPTABLE 30.0 7.176E+08 10858. 7.37 ---->ACCEPTABLE 35.0 7.050E+08 10667. 7.24 ---->ACCEPTABLE 40.0 7.026E+08 10630. 7.22 ---->ACCEPTABLE 45.0 6.996E+08 10586. 7.19 ---->ACCEPTABLE 50.0 6.962E+08 10534. 7.16 ---->ACCEPTABLE 55.0 6.923E+08 10476. 7.12 ---->ACCEPTABLE 60.0 6.989E+08 10574. 7.18 ---->ACCEPTABLE 65.0 6.865E+08 10387. 7.06 ---->ACCEPTABLE 70.0 6.741E+08 10200. 6.94 ---- >ACCEPTABLE

75.0 6.713E+08 10157. 6.91 ---->ACCEPTABLE 80.0 6.685E+08 10115. 6.88 ---- >ACCEPTABLE 85.0 6.554E+08 9916. 6.75 ---->ACCEPTABLE 90.0 6.553E+08 9916. 6.75 ---->ACCEPTABLE

95. 0 6.431E+08 9730. 6.63 ---->ACCEPTABLE 100. 0 6.441E+08 9745. 6.64 ---- >ACCEPTABLE 105. 0 6.446E+08 9754. 6.64 ---- >ACCEPTABLE 110. 0 6.451E+08 9760. 6.65 ---->ACCEPTABLE 115.0 6.268E+08 9485. 6.47 ---->ACCEPTABLE 120.0 6.284E+08 9509. 6.48 ---->ACCEPTABLE 125.0 6.116E+08 9255. 6.31 ---->ACCEPTABLE 130.0 6.058E+08 9166. 6.26 ---->ACCEPTABLE 135.0 6.001E+08 9081. 6.20 ---->ACCEPTABLE 140.0 5.948E+08 8999. 6.15 ---- >ACCEPTABLE 145.0 5.897E+08 8923. 6.10 ---->ACCEPTABLE 150.0 5.958E+08 9016. 6.16 ---->ACCEPTABLE 155.0 5.839E+08 8834. 6.04 ---->ACCEPTABLE 160. 0 5.921E+08 8958. 6.12 ---->ACCEPTABLE 165.0 5.755E+08 8709. 5.96 ---->ACCEPTABLE 170.0 5.596E+08 8467. 5.80 ---->ACCEPTABLE 175.0 5.801E+08 8778. 6.00 ---->ACCEPTABLE 180.0 5.649E+08 8548. 5.85 ---->ACCEPTABLE 185.0 5.772E+08 8734. 5.97 ---- >ACCEPTABLE 190.0 5.832E+08 8824. 6.03 ---->ACCEPTABLE 195.0 5.596E+08 8467. 5.80 ---- >ACCEPTABLE 200.0 5.728E+08 8667. 5.93 ---- >ACCEPTABLE 205.0 5.420E+08 8200. 5.62 ---- >ACCEPTABLE 210.0 5.769E+08 8729. 5.97 ---- >ACCEPTABLE 215.0 5.681E+08 8595. 5.88 ---- >ACCEPTABLE 220.0 5.705E+08 8632. 5.91 ---- >ACCEPTABLE 225.0 5.734E+08 8676. 5.93 ---- >ACCEPTABLE 230.0 5.768E+08 8728. 5.97 ---- >ACCEPTABLE 235.0 5.807E+08 8786. 6.01 ---- >ACCEPTABLE 240.0 5.958E+08 9015. 6.16 ---->ACCEPTABLE 245.0 5.928E+08 8969. 6.13 ---- >ACCEPTABLE 250.0 5.905E+08 8934. 6.10 ---- >ACCEPTABLE 255.0 5.886E+08 8907. 6.09 ---- >ACCEPTABLE 260.0 6.165E+08 9329. 6.36 ---- >ACCEPTABLE 265.0 6.151E+08 9306. 6.35 ---- >ACCEPTABLE 270.0 6.272E+08 9490. 6.47 ---->ACCEPTABLE 275.0 6.274E+08 9493. 6.47 ---- >ACCEPTABLE 280.0 6.410E+08 9699. 6.61 ---- >ACCEPTABLE 285.0 6.542E+08 9898. 6.74 ---- >ACCEPTABLE 290.0 6.315E+08 9555. 6.51 ---- >ACCEPTABLE 295.0 6.516E+08 9860. 6.71 ---->ACCEPTABLE 300.0 6.659E+08 10076. 6.85 ---->ACCEPTABLE 305.0 6.614E+08 10008. 6.81 ---->ACCEPTABLE 310.0 6.673E+08 10096. 6.87 ---- >ACCEPTABLE 315.0 6.729E+08 10182. 6.92 ---->ACCEPTABLE 320.0 6.783E+08 10263. 6.98 ---- >ACCEPTABLE 325.0 6.833E+08 10339. 7.03 ---->ACCEPTABLE 330.0 6.635E+08 10040. 6.83 ---- >ACCEPTABLE 335.0 6.990E+08 10576. 7.18 ---->ACCEPTABLE 340.0 6.961E+08 10533. 7.15 ---- >ACCEPTABLE 345.0 6.926E+08 10480. 7.12 ---->ACCEPTABLE 350.0 7.243E+08 10960. 7.43 ---->ACCEPTABLE 355.0 7.191E+08 10881. 7 .38 ---->ACCEPTABLE

ACCEPTABLE! MINIMUM SAFETY FACTOR - 5.62 AT 205.0 DEGREES.

GENE 00000006-2250-04a,Rev. 0 APPENDIX F- STRUCTURAL MARGIN CALCULATIONS FOR H6 21

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 08/15/2002

SUMMARY

OF INPUTS:

Title:

LG2 H6 E DLL RUN Angle increment - 1.0 deg. (COARSE)

Membrane Stress, Pm - 1203. psi Bending Stress, Pb = 4037. pSi Safety Factor, S - 1.39 Mean Radius, Rm - 99.38 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm - 14400. psi Fluence - 0.OE+00 n/cmA2 (Thus, LEFM evaluation not applicable)

THETAI THETA2 THICKNESS REGION Ideg. I [deg.I [inches]

1 .0 360.0 .470 LIMIT LOAD RESULTS:

=sS=-s--s=--s-t NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY (deg] [in-lbs] Ipsi]1 FACTOR RESULT 1_________ 3.42__ ---- C__T___E

.0 1.038E+09 3.42 ---- >ACCEPTABLE 16'725.

16725.

5.0 1.038E+09 3.42 ---->ACCEPTABLE 10.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 15.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 20.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 25.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 30.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 35.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 40.0 1.038E409 16725. 3.42 ---->ACCEPTABLE 45.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 50.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 55.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 60.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 65.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 70.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 75.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 80.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 85.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 90.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 95.0 1 .038E+09 16725. 3.42 ---->ACCEPTABLE 100.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 105.0 1.038E+09 16725. 3.42 ---->ACCEPTAELE 110.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 115.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 120.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 125.0 1.038E+09 16725. 3.42 ---->ACCEPTABLE 16725.

130.0 1.038E+09 3.42 ---- >ACCEPTABLE

135.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 140.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 145.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 150.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 155.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 160.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 165.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 170.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 175.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 180.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 185.0 1.038E+09 16725. 3.42 ---- ACCEPTABLE 190.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 195.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 200.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 205.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 210.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 215.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 220.0  ;.038E+09 16725. 3.42 ---- >ACCEPTABLE

1. 038E+09 16725. 3.42 ---- >ACCEPTABLE 220.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 235.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 240.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 245.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 250.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 255.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 260.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 265.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 270.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 275.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 280.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 285.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 290.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 295.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 300.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 305.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 310.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 315.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 320.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 325.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 330.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 335.0 1. 038E+09 16725. 3.42 ---- >ACCEPTABLE 340.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 345.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE 350.0 1 .038E+09 16725. 3.42 ---- >ACCEPTABLE 355.0 1.038E+09 16725. 3.42 ---- >ACCEPTABLE ACCEPTABLE! MINIMUM SAFETY FACTOR = 3.42 AT 180.0 DEGREES.

DLL: DISTRIBUTED LIGAMENT LENGTH EVALUATION, REV. 2.1 (09/19/96)

DATE OF THIS ANALYSIS: 08/15/2002

SUMMARY

OF INPUTS:

Title:

LG2 Shroud H6 NU DLL Run Angle increment 1.0 deg. (COARSE)

Membrane Stress, Pm - 675. psi Bending Stress, Pb - 2344. psi Safety Factor, SF - 2.77 Mean Radius, Rm - 99.38 inches Wall Thickness, t - 2.000 inches Stress Intensity, Sm = 14400. psi Fluence - 0.OE+00 n/cm^2 (Thus, LEFM evaluation not applicable)

THETA1 THETA2 THICKNESS REGION [deg-3 [deg.] [inches]

1 .0 360.0 .470 LIMIT LOAD RESULTS:

NOTE: THE FOLLOWING LIMIT LOAD RESULTS ASSUME THAT THE FLAWS TAKE COMPRESSION.

ALPHA MOMENT Pb' SAFETY

[deg] tin-lbs] [psi] FACTOR RESULT 6.10__ ---- AC_____L_

.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 5.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 10.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 15.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 20.0 1.lOIE+09 17746. 6.10 ---->ACCEPTABLE 25.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 30.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 35.0 1 .1OE+09 177 46. 6.10 ---->ACCEPTABLE 40.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 45.0 1.101E+09 1774 6. 6.10 ---->ACCEPTABLE 50.0 1.101E+09 1774 6. 6.10 ---- >ACCEPTABLE 55.0 1.101E+09 1774 6. 6.10 ---->ACCEPTABLE 60.0 1.101E+09 1774 6. 6.10 ---- >ACCEPTABLE 65.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 70.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 75.0 1.101E+09 1774 6. 6.10 ---->ACCEPTABLE 80.0 1.101E+09 1774 6. 6.10 ---->ACCEPTABLE 85.0 1.101E+09 11746. 6.10 --- >ACCEPTABLE 90.0 1.101E+09 1774 6. 6.10 ---- >ACCEPTABLE 95.0 1 .1O1E+09 17746. 6.10 ---- >ACCEPTABLE 100.0 1.101E+09 1774 6. 6.10 ---->ACCEPTABLE 105.0 1.iOlE+09 17746. 6.10 ---->ACCEPTABLE 110.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 115.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 120.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 125.0 1.101E+09 17746. 6.10 ---->ACCEPTABLE 130.0 1.101E+09 17746. 6. 10 ---- >ACCEPTABLE

135.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 140.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 145.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 150.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 155.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 160.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 165.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 170.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 175.0 1 -IO1E+09 17746. 6.10 ---- >ACCEPTABLE 180.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 185.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 190.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 195.0 i.;O1E+09 17746. 6.10 ----. ACCEPTABLE 200.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 205.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 210.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 215.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 220.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 225.0 1.1O1E+09 17746. 6.10 - ->AC- Iv'ThLE 230.0 1. 1O1E+09 17746. 6.10 ---->ACCEPTABLE 235.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 240.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 245.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 250.0 1. 10 1E+09 17746. 6.10 ---- >ACCEPTABLE 255.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 260.0 .O1E+09 17746. 6.10 ---- >ACCEPTABLE 265.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 270.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 275.0 1.101E+09 17746. 6.10 ---- >ACCEPTABLE 280.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 285.0 1 .O1E+09 17746. 6.10 ---- >ACCEPTABLE 290.0 1 . 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 295.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 300.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 305.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 310.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 315.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 320.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 325.0 1. 1O1E+09 17746. 6.10 ---- >ACCEPTABLE 330.0 1 .O1E+09 17746. 6.10 ---- >ACCEPTABLE 335.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 340.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 345.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 350.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE 355.0 1.1O1E+09 17746. 6.10 ---- >ACCEPTABLE ACCEPTABLE! MINIMUM SAFETY FACTOR 6.10 6 AT 145.0 DEGREES.

GENE OOO-0006-2250-04a,Rev. 0 APPENDIX G- INSPECTION RECORDS OF WELDS Hi THROUGH H7 22

GE Nuclear Energy Interim Report Limerick Generating Station - Unit 2 Core Shroud Ultrasonic Examination Preparedfor PECO Energy Preparedby:

GE Nuclear Energy Report No.: I H61 R, Rev. 0-May 1999 PreparedBy: E ction Services, Sr. NDE Speciast Date: //Z/4 Leve I - UtnonicAethod Reviewed By: Date:

In o sevices, Projedt Manager L

RIfaj'dXeCh.

Reviewed By:  ? a4 Thomas Anderson, PECO Enery, JSI EngineAr C)at,: /g/ ?_ _

Report 0o Rev.O Apd 199A- - -. -.-- -.-. .

GE NuclearEnergy Project Summary From 29 April 1999 through 8 May 1999. General Electric (GE) Inspection Services conducted ultrasonic examinations of Core Shroud Assembly welds at Limerick Generating Station - Unit 2. The scope of the examinations included selected portions of four circumferential welds. H3, H4. H5 and H7. The detection of flaw indications forced an expansion of the work scope to include the examination of acoessible porions of welds HI, 1-2 and H.6.

All welds were examined using the GE OD Tracker scanning device, while employing the conventional technique, which uses 45 shear wave, 60° -longitudinal wave and OD/ID Creeping wave search units in an integral housing. I This report contains specifc details regarding the performance and results of the examinations.

References

.. ASME.Boilef and.Pcessur.Y'essei.Cod, SectiqriXl, . PJlq r sp;ice 9!Ilspectif

ie Power

. Pleno CorpOfleJtS.. 188 etWaOf .-............. ........

Note: The ultrasonic examinations described in this report are not addressed by the ASME Code.

The examinations were performed In accordance with the intent of ASME Sections V and Xl with regard to the basic ultrasonic requirements, whenever possibe.

Generat Electric document GE-UT-503, Version 8, Procedure For Automated Ultrasonic Examination Of Shoud Assembly Welds.

Equipment T

The capabilities of the MicroTomol' data acquisition system, TomoView " Workstation and GE Trimodal search unit were successfully demonstrated in accordance with BWRVIP-03 Reactor Pressure Vessel and internals Guidelines.

MicroTomo n'Acquisition System The MicroTomno data acquisition system was utilized for this examination. The MicroTomotM is a multiplexed, digital system. The system digitizes the entire A-scan or RF waveform at the rate of up to 120 MHz. The entire A-scan Is digitized and archived to a one gigabyte optical disk or 2 gigabyte removable hard disk for off-line analysis and subsequent examination comparisons.

OD rackerScanner This device rests upon and drives around the steam dam structure of the core shroud assembly.

Interchangeable vertical arms of appropriate length descend from the carriage of the GE OD Tracker to the elevation of each of the four welds examined. The search units are applied to the outside surface of the shoud and are manipulated about the accessible portions of the circumference of the shroud. Search units are also moved toward and away from each weld, in a raster scan pattern. ThTis scanning motion generally provides 'ull coverage of the BWRVIP-specified surface regions on both sides of fle weld.

Repat 0077;Rs 0 APr 1999

a GE NuclearEnergy Tomo View TE Data Analysis Workstation of ultrasonic data. The data is displayed with The TomoVIewtI Workstation was used for the evaluation views, with 1024 X 768 pixel any combination of time or amplitude in A-scan. B-scan, C-scan and D-scan T any desired manipulation of the A, B, C or D-scan images.

resolution. The TOmOVieW 'msoftware perrnits enhancement Each iMage or specific region therein.

An adjustable color palette is provided for image have used the TomoViewm software to successfully can be selectively enlarged. GE data analysts NDE capabilities in the PDI Piping Program at the EPRI demonstrate complete flaw detection and sizing Center.

Report O712 Rv. O Ap 1999

.a

GE NuclearEnergy Examination Results Numerous indicationS of intergranular stress corrosion were observed during the course of the examinations of welds HI. H2, H3. H4 H5 and H6. The examinaion of weld H7 did not reveal flaw indications. This document also contains a section of Examination Summary Sheets for each weld examined.

Examinaiton Personnel The examinations were conducted by the follovwng GE Inspection Specialists:

M4icroTomo "'CarouselbOD Tracker System Operators:

Martin Crane Level 11 Nicholas Labella Level It Terry Rckwood Level II Michael Webster Level 11 Ultrasonic Data Analyst John Hayden Level II James Halley Project Manager:

Richard Keck 999--- ~ ~

R~~~~~i~~~~~&7flReY.OAPtV ~ ~ ~ - ,- " -- . - - -- -

Weld Ml t xamination from 13ottom Side of Weld-*5 &ODCr Coyraae Total Scan Length Ezamoed (DogJ 20.56' Shroud Thckness (n.) 2.00 Total Scan Length Examined (In. 396.78 Cl/runm ne an.) 691.15 Ptrcent of Weld Length ExamIned 57.41% lnchs per Deg,e 1.92 Percent of Evamined 00 Weld Length Flawed 24.30%

Peront of Ttbl 00 Weld Length fiewed 19.59%

Percent of Examined 10 Weld Length Flawed 31.96%

Pwcent of ftinl tO Weld Loegth Flawed 18.34%

45 - OCDr Looking 45e ODCr Up Data 45 Scan scon scan OCr Scan 45OCr J4ODCr Ligement Ligament Ugament Files Stat End Start Scan End Lenglh Coveraga. Overlap Start End Length TrlModel HIH2011.1 12.06 16.46 11 01 15.41' 4.40' 5.46, 3.9 11.01 39.46' 28.4r Tr[Model H1H2015-1 13.56' 24.01' 125C1 22.06 10.45 11.50' 4.00' TrlModal 1H2026-1 21.08' 31.81' 20.01' 30.4C 10.45 11.W 7.95 TrlModal H1H2033-1 2461' 39.48' 23.56 3a.41' 14.35' 18.90 TrlModal HiH206I-1 61.56' 6641 501 65.36' 14.9 15.00 12.99' 50.51' 126.46' 71.96' TriModal HIM203-1 54,4r 14.3r 13.42 6332 9. 00 10.96' 3.45' TrlUodal Hl12071-1 61.9r 72.420 60.92' 71.3r 10.46' 11.50 4.00' TriModal HIHIO7S-1 68.47' 79.92' 68.4r 76.87' 10.45' 11.50' 4.00' a, TrModal H112086-1 76.97 87.420 76.92' 86.37' 40.4' 110 4.00' 9, TrMol H1H2003-1 84.47' 42 83.4r 93.97' 10.45' 11.80' 4.00' \:

TriModal 141H2101-1 91.97 10L4r 90.9r 101.3r 10.45' 11W -4 4.000 T Modal HIH2108-1 9947' 112.67' L42 111. 13.20' 14.25' 2.66' TrlModal 1H2116.1 111.0' 126.46 110.01 128.41' 1540' 16.45' TnNdal HIH2191-1 191.56' 19.81' 150.81' 16.46' 4.95 B.0O Lvr 190.61' 219.81' 29.37 Tnt1odl 1N1H2108-1 1094.590 2O.04' 193.54' 203.99 10.45' 11.0 03' Trlodel H14N11U2-1 201.08 211.51' 200.01' 210.48' 1048 11.5r 7.05' TrModal 1,22131 204.61' 219.B 203.58' 2153' 15.27 16.32 TtNModal IH2243-I 234.61' 244.92 233.6' 243.87' 10.310 11.36' 4.00' 232.6 306.46' 72.90 TrModal 1H2261-1 241.97' 252.4r 240.920 251.3r 10.4 11.50 4.00' TrIModal 81142268-1 249.47' 2.92' 248.42' 258.6r 4045 11.50 4.00 zX TnlUodal 14IH2226-1 256.9r 267.4? 2J502' 28.3r 10.4 11.50 4.00 TriNodal 4H12273-1 264.4r 274.92' 2.4r 273.7 10.41' 11.50' 4.00' TriModl H112211.1 271.9r 281.87' 270.92 280.8 9.90' 10.95' 34 0W 11H221&i 279.4r 292.6r 278.4r 291.62' 13.20' 14.25 TntiMod TrNoMd H1H22084 291.06. 306.44 290.01' 306.41* 18.40 1.45 2.'

a.g TnJUoduI 303.48 91.00' Ii Tobal camd: 303.68 ovtlap: 97.00' Toul LIaivl Length: 206.64' Net Cwnoerage 208.66' Pinrcen*a *ofWsld8csnn. 57.44% P4rcentog aof Totl Weld LenRIh.: 17.41%

/ - /. L-

Weld HI Insid Set Fl OuhIds Surta@ FIa*

Flaw Flaw Length Flaw Few Length Flaw Weld Inftlating Flaw Stert Moew End Length Length Seae Flow Weld InitIating Fw Start Flow End Length Length Search 5urt ce ir;s ID. es) freed £Qflrhi Int t, Side  : eegess (D £ eors flngnchn) Lh 1' NS ID 12.03' 16.43' 4.4' 8.46 00Cr I' NS 00 r res to 13.1t' 21.2t' ,16' 11.65 45.0 1.ev 39.46' 20.4' 3t.17 Or r NS 00 21.2!' 22.U1' r Ns 1.63' 3.13 4.00' ID 8L2 70.67' 6.30' 1e.13 00cr r KS DO 24.6' 2J.2i' 3.85' A Ns 7.39 45.00' 6* "a 10 72.2 73? 1.16 .11 0OCr 4' Ns OD 54.33e 8.af1' 4.96' .50 r NS tO 45.00' 74.r T.17 4.2' 5.06 ODCr 5' KS OD SI?'r 84.1' t2r 8' NS 4.22 4J.00' ID t4.4r 33.r 3,85' 7.1 00Cr 6' NS OD 73.62' 8.2' 3.66' 7.01 45.06 ID 81.0r1 94.1' 3.24 8.22 OCr 7 on la NS HS Sir 81.3 3.46' 2.29 46.00' lb 116.0V 120.4r 4.46 6.46 OCr 6 II No NS On 32.1r 34.92 2.7* 6.26. 45.66 1D 129.90' 122.03 1.16 2.11 OCr 6 NS On 11 KS 93.0?, 1.1' 1.10 2.11 43.0o' ID 20.61* 209.31 3.W 1.34 0DCr 1C NS 00 9.6r 101.3r 1.65' 12 NS 3.17 43.6o ID 215. 21.1r 1.36 3.17 OC It, NS 0 101.31 183.32' 1.61' 3.1?

. M NS 45.0e In 233.4' 240.11 1.H3' 3.17 00C Ir NS On 103.8r t8e2 2.76' 3.28 45.06' 14 pS lo 26.32' 24.6r 2.76' 5.23 OCr Ir NS On 107.17, 12SAS' 1.29 37.04 4S.06' le, NS ID 27r.4r 2e0.Sr 3.16' 6.36 OC I4' KS Is NS

.00 2t2.5e 214.J9' 2r 4.22 4.f 10 214.31, 236.6' 2W 4.22 O0Cr 15 NS 00 243.07 244.17 .10' 17' NS .11 46.000 10 27.11' 204.26' 7.11 13.73 00Cr 15 NS 00 2941' 29.ee 2.r 5.21 4S.0 to NS D e30S.w 303.43' 1.16' 2.11 OCr 6.or 121.73 70.39' 136.11 I1 IEWED PECO NUCLEAR2'99 NOE SERVICES BRAN47Z& -299 9 ttW 4 57/1/729

Woki Hi Inide stidA Flaw* outside Swlece Fls No. Location thmnughiW.hl ight No. Location Though.Wall Heght lb. Location ThtghW&U Hlght No. Lpr*i.n Thou.WaII Hight No. Lacaiofi Th gh11WaHNsight i 13J 0.1 24 117.1, 0.11 1 13.3 0.13 23 *11.21 0.14 U 114 0.13 2 1U.4t 0.1 25 11' 0.t 2 13.71' e.10 24 41.3? 0.14 40 1.7r Q1

24. ." 1 115.1W D2 3 1621' 0.14 2t. "T' V1 4 117J 0.14 4 21.34 0.23 27 107.11r 0.34 4 37 l 0.1 16.: .A.S1r .12 4 121.1' 4GM S 23.64 0.14 22 201.73 17 5 17.4,1 L1 21 MAI, 6.12 4 131. W 0LOs 24.3 .4 28 21.4' 6.4 I 1.05' 0.14 2. nar 0.u r0 12 ti 6.11 7 24' .3 30 20&4 Ml 7 1.3 6.33 U1 26 Il.? L14 1232r 0.6
  • 1.W P.53 31 216.11' 6.15 I 30.3 L14 30 JAr .16 U 124.3r 0.14
  • 31.04' Ut 32 30AI1' ut
  • 10.1' 1 31 ftr .4 53 212.73' .14 40 33.3 an 33 22.3W 5.0? 10 221r 0.14 32 ftr 0.19 ui 21.2W 0e 11 34.W Mie s4 "o. 0.1 11 223W 0.16 S3. 0.t1r A U 143.r 0.14 12 321' 0.23 3 2S.", us It 24.31' 0.14 34 15.2? 00 56 210.4 L13 13 54.51 04 2*.40w 034 13 24.W 6.12 1 35 1.r 6.12 or 233 0.10 4 67.0? 5. 37 law 5.35 14 24 14 34 102.4r 0.1 3. 0L0 Is 0.11 1.17 36 2.74 02 11 17.11- 0.11 37 3tO0.3 5.14 1 "f.' 0.11 30 .4 0.1 1 23 0.12 3 10.2r (1s 17 72.77 d.e6 Ad 300.r .38 1? "r 0.16 30 tn.3r 0.13.

II nA1 1I7 41 301A95 0.24 1s 5L4 .14 40. 100.6r 0.10 1 75.13' 3.2 41 303 O 400 It 56.61 L14 41' .r O0.18 20 Ku.l k 43 30 .3 Me l0 17.1' 6.1 42 11.1' 0.13 21 67.31' 00 31 61r 0.16 432 112.1' 0.16 2 62.31' 0.13 22 77.17' .14 44 113AW 0.30 22 03.15' 0.12 SEVIEWED PECO NUCLEAR 2//

NDE SEFIVICES BRANCH" ' MWI a99 4 -

Weld H2 Eramlna lion of TOO Side Of Weld - 40 £ 00Cr Covereti; totalScan Length EamIed (Dog.) 206.80' Shroud Thckness (n.) 2.00 Total Scan Length Examined n.) 397.05 Circumference (In.) 691.15 Percent of Weld Length ExamInod 57.44% Inches per Degre 1.92 Percent of Examned 10 Weld Length Flawed 39.54%

Percent of Total IDWeld Length Flawed 22.71%

81.77 45ODCr TrModal HIH2011.1 12.03' 16.43- 10.98' 16.38' 4.40' 5.40 .3.95' .10.98' 39.30' 28.32' TrModal HIH2018.1 13.53' 23.98' 12.48 22.93 10.450 11.60' 4.00' 0.00' TrModal H1H2026.1 21.03' 31.48 19.9, 30.43' 10.46' 11.50' 8.28 0.00' TntModal H1H2033.1 24.26' 39.30' 23.20' 38.25* 15,050 16.10' . 0.00 TrIModal HiH2068.1 51.53' 68.38' 50.48' 65.33' 14.85- 15.90' 12.98' 50.48' 126.43' 75.96 Trtodal H1H203.1 54.45' 84.30 53.40- 83.30' 9.90' 10.95' .3.32' 0.00' TntModal H1H2071-1 62.08' 72.53' 61.03' 71.48' 10.45' 11.50' .4.13' 0.00' TntModal H1H2078-1 69.45 79.90' 68.40' 78.85' 10.45' 11.50' 4.00' 0.00.

TrtModal H1H2080.1 76.95' 87.40' 75.90' 86.35' 10.45 11.50' :3.98 0.00' TrIModel H1H2093-1 84.47' 94.90' 83.42' 93.85' 10.43' 11.48 4.00' 0.0' a TnModal HIH210-I1 91.95' 102.40' 90.90' 101.35' 10.45' 11.50' 4.00' 0,00 TntModal HII2108-1 99.45' 112.65' 98.40' 111.60' 13.20' 14.25' 2.67' 0.00' TniModul H1H2116-1 111.03' 126.43' 109.98' 128.38' 15.40' 18.45' 0.00 .

TrtModal H1H2191.1 191.53' 196.48' 190.48' 195A3' 4.95' 6.00' 3.00' 190.48' 219.85' 29.37' K TrtModal H1H2198-1 194.53' 204.95 193.48 203.90' 10.42' 11.47' 4.97 0.00' TniModal H1H22061 201.03' 211.48' 199.98' 210.43' 10.45' 11.50'95 .. 0.00' TrModel HI1H2213-1 203.98' 219.85' 202.93' 218.80' 15.8?' 16.92 0.00 '9 TnlModal 1H2243-1 234.45' 244.90' 233.40' 243.85' 10.45 11.50' 4,00' 233.40' 306.57' 73.17' TntModal H1H2251.1 241.95' 252.40' 240.90 251.35' 105' 11.50 4.00' 0° TnModal H1H22J8-1 249.45 259.90' 248.40' 258.85' 10.45' 11.50' 4,00)

TriModal H1H2266-1 256.95' 287.40' 255.90' 26625 10.45' 11.500 . 4.00' .- 'm TrModal H1H42273-1 264.45' 275.03' 263.40' 273.98' 10.58' 11.63' 4.13' TlModal H1H22811 271.95' 281.98' 270.90' 280.93' 10.03' 11.08' 3.688 TntModal H1H2288-1 279.45' 292.85' 275.40' 291.60' 13.20' 14.26' 2.55' H1H2206-1 291.15 306.5r 290.10' 305.62' 15.42' 18.47' 'L 304.83' 98.03' .3 Total Ugment Length: 206 .0' *uW

  • P0860' UlC Percentage of Total Weld Length: 57.44% Z
  • . S4c4)~4~A 6//./9

Weld H2 Inside Surface Flaws Flaw Flaw Length low Weld Initiating Flaw Start Flaw End Length Length Search No. Side Surface (DeQrees) (Dearees) Unit (Mearees) (Inches) 1' NS ID 12.72' 20.82 8.10 15.65 45.

2* NS ID 23.49' 28.14' 1.65S 3.17 45.

3 NS ID 34.49' 35.590 1.10 2.11 4 NS ID 36.140 38.34' 2.20' 4.22 45*

5' NS ID 50.570 57.33' 6.76' 12.98

  • 45*

6* NS ID 64.28' 70.88' 6.60' 12.67 45.

7 NS ID 72.330 4h' 73.98' 1.65' 3.17 8* NS ID 74.53' 81.480 6.95' 13.34 45-9* NS ID 98.48' 99.58' 1.1U 2.11 10 NS 1D 114.47' 116.12' 1.65' 3.17 45' 11 NS ID 117.77' 119.97' 2.20' 4.22 !45.

12 NS ID 124.92' 125.47' 4.

1.6S' 3.17 4S.

13 NS ID 191.12 19.5r 4A0 8.46 48' 14 NS ID 201.72 203.37' 1.65' 3.17 45S 1s NS ID 203.92' 205.63? 1.71' 3.28 45.

18 .NS ID 233.48' 235.68' 2.20' 4.22 4e;1 45' 17 NS ID 243.18' 261.48' 18.30' 35.14 45 18 NS ID 278.13' 287.83' 9.70 18.62 19 NS ID 294.470 295.57' 1.10' 2.11 20 NS ID 304.37' 305.47' 1.10' 2.11 45.

81.7r 157.00

.I

  • Flaw detected In adjacent overlapping scan region. 9 R&I-DIEWC-1 PCW 1tL1aAh /

b3' WLiR BRA NCU DESERVICESBRNY MAY j*-299 9t 9:9 4.

Weld H2 Insfde Surrace Flaws No. Location Through-Wan Helght No. Locatfoh Through-Wall Helght I 13.15D 0.12 32 195,i30 0.17 2 13.03' 0.12 33 19623 0.18 3 14.68' 0.11 34 203,93' 0.26 4 17.43' 0.09 35 204 934 0.24 5 20.18 0.11 38 204.50t 0.05 a 20.53' 0.11 37 234i50 0.18 7 23.285 0.17 38 235605' 0.16 a 24.50' 0.10 39 23t460? 0.09 9 34.95' 4O.OS 40 244,40' 0.18 10 37.15' (0.05 41 246i38r 0.07 11 51.03' 0.10 42 247;03 0.14 12 63.23' 0.12 43 248.6V 0.18 13 *54.33e 0.17 44 251;.43n OM1 14 54.50' 0.09 45 256,10' 0.15 16 64.75' 0.28 46 2577 0.17 16 69.15' 0.18 47 256.45' 0.1 8 17 69.50' 0.18 48 25t.55." 0.16 l8 72.80' 0.31 49 2519.7i5 0.18 19 77.00 0.14 50 280d.21 <0.05 20 78.10' 0.08 51 21 80.85' 0.05 52 282.80.' <0.05 22 99.15 0.23 53 28i.4k 0.11 23 98.95' 0.17 64 250,83 (0.05 24 102.88' 0.24 65 285.73' <0.05 25 115.02 O.1 56 292.94' 0.05 57 305.39 <0.05 28 118.79' c0.05 * .

27 125.39' 0.17 28 191.6, 0.08 29 192.37' (0.05 30 192.68' 0.09 . I 31 194.42 0.24 I Note; All Inside surface naw slzed using the 60 degree search unlt.

REVIEVVED J PFrANU BIANGHM t4 E AiCEs V '9 F9 - /'/

LIMERICK-2 SHROUD UT INSPECTION A7MUTH ZERO (NORTH I

i

~~~~~~~~~~~~~

1N_REA iv w_- _

H3 rXAHINATiO H3 OD INDICATION REAS H'3 EI NDICATION APEAS I

i i

Weld H3 ftealm,tlo,n ftm Bof om Stdo of Mid 45 AOCr Covue Toftl Scan Length Examined (Dog.) 221.516 Shrod rhikness (7.J LOD rota seen Length Enmin,d (nj 400.31 . Cicumaret n.) 650.69 Preent of Weld Length ftemined 61.63% lhe per Dege 1.81 Perent of Elmined OD Wed Length Flwed 68.4%

Percent ofrTotel 00 Wld Length Flawed 3o.7% 10 136.04 Percent of Examined ID Weld Leng Flalwed 61.4% OD 110.0 Percent of Total I0 Weld Lngf Flawed 37.8%

__ . 45 . OXDv Loo 4S° 45° OOCr Up Data Scan Scan Scan ODCr Scan Scan 4P.OpCr 45-ODCr LIgoment Ligament Ligamernt Fes Steil End Starl End Length Clve6ge Ovedrhp Start End Lengt*

TrModel H301iLUI 6.09' 1.,99' 5.04' 14.94' 9.90 '10.95* 3.45' 6.04 31.91' 34.

trIModel HJ301WU¶ 13.5S' 24.04' 12.64' 22.9 10.45' 11.S0' 4.00 TrIModal H302CLU1 21.06' 31.64' 20.04' 20.4t9 10.46' 11.60' 6.06' TrMoal H3033LD1 24.61' 39.01' 23.46' 38.8' 15.40' *18.5' TrnModal 1,306LUI 61.096 01.84' 50.04 80.49' 10.46' 60.04' 109.90' 69.r (1.60' 4.00' TdMoetl H3063LU1 54.61 04.98' 93.46' 83.91' 10.45 11.50' 4.

T dal "3071LU1 62,1' 72.48' 60.96' 71.41' 10.46' TrModel 113078u1 89.61' 79.9' 69.46 79.91' 10.4r IJ' 4.00' TrModel H30tILU1 77,01' 87.46' 76.16' l6.41' 10.46 .11.00 4.00' OS tn T Ml H3093LUI 94.61' 94.29' 83.430 93.91' 10.45' 11.0' 4.00' T dal H3OILUI 92.1 102.46' 96.96' 101.41' 10.45' 11.60' 4.000 TtModal H31LU 1 99.11' 10.' 16.460 108.91' 10.45 '11.56' TrlMdl H3111LU1 111.1' 121.48' 10.64' 126.44* *15.40' 110.04 121.4' 18.45' T odl tt31t1.0 1193.71' 193.61 1192.88 192.58' 9.0 9.45'. r.sr 1i2.6 219.91' 37.26 -

TrlModel W,Mt.i 19S.W 191.64' 19B64' 196.41' 10.46 TtModel H3101 193.69' 204.04' 192.64' 202.99 10.4 11.60' 4.00' 11.60' 6,01' TrModel H3209-i 201.09' 211.64 200,04 210.4' 10.463 115' 4.00' TrlModal H3213-1 204.61' 219.91' 203.46' 2196.' 1940' Trilod.l H324tLt 2314.61' 244.41' 233.46' 243.36' 9.9' 10.96' 3.46' 233.40' 3M.49' 73.O TtIModel H3251LUt 242.01 282.Wr 240.91' 251.41' 10.46' 11.6 4.0e Tffwdul Hl73stWI 249.tr 2."' 246.46 266.91' 10.46 11;60' 4.00-200.41' 10.46 t1.60' 4.0W z TntModal H32988UM 267.01' 287.48' 256.'

273.91' 10.45' 11.60' 4.00' TtModol 1132721 284.61' 274.' 203A60 TrModal H3281LU1 272.01' 221S' 270.J6' 281.41' 10.460 11 50'

14:26' 4.0W' 2.75 o

TrFtMd.Fl H32ttl 27.51' 292.11' 2711.40 291.88' 13.20' ,,

TnModal H329itW1 291.01' 30.49' 269.90 30S.44 16.46' *&53 18.. UIF rOw

1.0 9.0 Li Teoal Scanned: 319.90' Total Llparent Length? 221.61' O yfte7: 96.40' Net Cow"ee: 221.51' Percentage of Total Weld Length: 81.62%

Perntage of Weld SGcmned: 61.63%

.- % . - i . . .

It

( V.-().. , 419?

Weld H3 Weld H3 Inside Surace Flaws Outside Surace Flws Location Through-WaU Height Locallon Through-Wall Height 6.6 0.22 91.16' 0.22 Location hrouoh-WAII Height Location Thiough-Wall Helght 9.99 0.19 100.66 0.10 6.64' 0.15 254.46' .16 11.0' 0.18 101.76' 0.10 a.2s' o.1t 255.56' .15 13.29 0.25 103.41' 0.26 9.39 0.11 25.11 0.16 14.94' 0.10 104.51' 0.21 10.49' 0.11 261.04 '0.05 16.09' 0.28 101.61' 0.24 12.14 0.11 262.61 0.10 21.84' 0.38 107.26' 0.10 13.240 0.17 265.26' 0.11 22.24' 0.26 110.5J 0.20 19.64- Oil 266.71 0.15 23.49' 0.24 111.9' 0.10 82.76' 0.2 268.91' 0.10 2884' 0.34 113.84 0.21 7226' 0.19 274.41' 0.10 27.74 0.25 115.49' 0.18 74.46' 0.0? 276A1' 0.08 30.49 0.31 117.14' 0.20 75.58' 0.16 280.26' 0.11 31.71' 0.27 125.99' 0.27 76.11' 0.21 282.94 0.24 33.38' 0.26 194.39' 40.05 90.31' 0.1 292.74 0.12 34.48' 0.17 197.49' 0.19 106.68'0 ON 297.146 0.12 36.11' 0.25 210.01' '0.05 107.76' 0.16 51.89' 0.21 21.46' 0.06 109.6' 0.22 53.34' 0.16 217.21 0.19 114.39' 0.17 56.54* 0.36 216.31' 0.05 116.04' 0.14 67.74' 0.28 235.11 0.10 187.570 -'05S 61.71' 0.18 236.21' 0.19 188.17' c0.05 63.39' 0.30 243.71' 0.16 18.77 O.C9 64.460 0.25 244.26' 0.19 191.97' C0.Q 85.91' 0.31 24L36' 0.19 192.69' (0.05 67.01' 0.39 246.48' 0.10 194.34 (0.05 8.86' 0.27 2411 0.14 l9509' 0.05 69.76' 0.23 250. 0.17 216.06' 40.06 72.31' 0.25 25.41 0.11 217.71' (0.05 73.9t' 0.38 258.71' 0.10 235.08' 029 75.0' 0.37 257.a6 0.17 236.T 0.14 76.16' 0.24 258.16' 0.30 240.r 0.33 7'7.SV 0.27 20.71' 0.13 242.76' 0.15 78.71' 0.24 201.14' 0.10 241.8'6 0.15 80.3' 0.32 20or 0.11 245.06 0.15 02.8' (0.08 29894 0.10 249.71' 04 V 8531' 0.24 301.52 (.s 251.38' 0.14 65.6 0.22 304.3r (0.06 25.38' 0.47 *1 8841' 0.24 REVIEWED ECO NUCL d MAY 1 299 NDrE SER%VICESBR 9(4, Q44 o//4/9v

lAW SUMMOMfOr Weld 3 Ousdie Surface Meqws lMidl Surface Flavws Flaw SLar Elaw End Lnh ,l1bJIn FlIv;EStt: Flaw End Lenath Lenath (In.}l 1* .17' 14.97' 8.80' 15.93 ,6.09' 1' 39.91' 33.8r 61.21 2 18.82' 22.27" 3.65' 8.81 2' 51.C9 80.88' 29.77' 53.88 3 10.69' 63.94' 3.25' 5.88 3 SlAP1 83.06' 1.65' 2.99 4 68.69' 73.44' 4.15' 8.60 4 84.7t 89.46' 4.75' 8.60 5 73.99' 76.74' 2.75' 4.98 .90t.f- 1,6 a 1.10 1.99 6 79.29* 80.94' 1.65' 2.99 99:51w 117.69' 18.18' 32.91 7 81,49' 83.14' 1.65' 2.99 .7 124.84' 128.49' 1.65' 2.99 8 105.64' 108.94' 3.30' 5.97 8' i 81l2@ 203.29* 15.17e 27.48 9 113.92' 117.77 3.85' 8.97 9 2i '.86 219.91' 6.05' 10.95 10* 186.46' 198.64' 12.08' 21.86 10 234.51' 237.28' 2.75' 4.98 11 208.79' 210.58' 1.77 3.20 11 13.31" 240.01" 1.700 3.08 12 212.21' 218.81' 6.80' 11.95 12 243.11' 249.16 6.05' 10.95 13* 233.49' 263.14' 29.65' 53.87 13 253.06' 251.91' 1.85' 3.35 4 283.89' 285.89' 2.20' 3.98 14 252.81' 253.910 1.10' 1.99 15 266.24' 269.54' 3.30 5.97 15 255.560 268.86' 3.30' 5.97 16 270.99' 281.24* 10.25' 18.55 16 25i.96' 262.16' 2.20' 3.98 17* 282.34' 288.19' 3.85' 6.91 17 291.09 292.19' 1.10' 1.99 18* 292.27' 295.02' 2.7r 4.98 18 294.94' 298.79 3.85' 6.97 19 298.67' 298.32? 1.85' 2.99 20 301.07' 302.17' 1.10' 1.99 21" 303.27' 304.92 I e5' 2.99 If II II, fIEVIEWED PECO NUCL EAR NDE SERVICES BRANCH 1299'M H

WI" 99444fi/9

LIMERICK-2 SHROUD UT INSPECTION AZIMUTH ERO (NORTH)

~

-~~ ~ u . ,..,.

H4 INDICATION AREAS

. SKETC RELEASER CORD L 1 04-11-991 f -. -_e SHRO0 CVRG I_ - I. I I __

Weld H4 Totl Scn Length xaand (Dfg.) 218.23 Shroud th 1kne (IL) 2.00 Totl Scaa Length Examined (InJ 3.44 Clrcumhwnce (Ii)J 650.69 Peraent of Weld Length Examnd 60.62% Inch" per Degr1ee 1.61 Percent of ExamIned Wld Length Flawed O.0'h Total Flawed Length (ti.) 00 Pecent of Total Wld Lth Fiawid 0.0% ToW Flowed Ligu) (Do ).

. 45ODCr Looking ODCr ODCr 450 Up Data Scan Scan Scan 450 Scan Scan 45-ODCr 45-ODCr Ligament Ligament Ligament Fileas start End Start End Length CoweragQ Overlap Start End Length TnModal H4011-1 6.07' 12.77' 4.0? 11.72' 7.70' 8.78' 4.02 12.7r 8.76 TnModal H4026-1 1?.01' 268.1" 1C.95' 24.76 8.80' 9.85' 6.79 16.9' 36.47' 19.61',

TrUJodal H4028-2 20.07* 36.47 19.0 34.42' 15.40' 16.48' TrUModal H4058-1 51.09 68.58' 60.04' 66.63' 16.49' 16.64' 13.12' 60.04' 130.26' 80.21' H4063.1 64.51' 89.01' 53.46' 68.868 16.40' 16.46' 148 Trniodal H4074-1 69.61' 84.91- 68,46' 83.86' 16.40' 1646 1.45' Trnodal H4091-1 84.81 99.91' 83.46' 16.40' 16.45' 1.4' H4108-1 99.610 114.91' 98.48 113.58' 16A0' 168 1.11-TrnModal H4116.1 114.5' 130.26' 113.50' 129.20 165.40 TriMadal Tniodal H4191-0 183.17' 193.69 182.12' 192.64 10.42' 11,47' 8.56 1B212 219.91' 37.79 H4191-1 186.09' 194.54' 166.04' 196.49' 10.45' 11.60' 4.00 TriModAl H4198I 19369' 204.04 192.64' 202.9' 10.45' 11.60' 4.00' TnModal H4208.1 201.09 211.64' 200.04' 210.4V 10.46' 11.60' 8.08 TriodS 16.48'.;.

TriModal H4213-1 204.61' 219.91' 203A. 21L88 16A0-l H4243.1 235.65 249.86' 234.50' 248.80' 1430' 15.55 136 234.50' 306.48 71.W8 TrUdoda 16.48' 1.3 TrNdal H4260-1 24.65 264.94' 248.60' 263.90' 16.40' TriMgodal 114273-1 264.60' 279.90' 263.4C' 278.85' 18.40' 16.46' .45' Trnodal H4285-2 279.50' 294.90' 27546' 293.85' 16.40' 16.45': 4.87' TnMoal H4298-1 291.05' 306.48' 290.03' 305A3' 16.40 18.48' 277.36@. - 6S.13 TiWt Scanned: 277.35 Overlap: 69.13' Tota Ugament Length: 218.23' Net Covarage: 218.23' Percentage of Weld Scadand. 60.62% Percentage of TotWl Weld Length: 60.62%

. I REVIEWEDEpO 4UNUC !AY I: 2 99 NDE SERVICES BRMtCIif2 Ls/-/Z 2'9

WeldH4 P2 nefon o Top SO wtWeMd.45 &OOr Coae TotaI Soon Length Eawnrfiwd (DJ 22.66' Shrmud ThICkneIt in.) 2.00 TeOSCM Length &Wnm.(ln.J 416.08 Cfeum.rc (PnJ 160.69 P0nt of Wld Legm Exr. e 63.71% lnch usperl2 e 1.81 Permenl of Emmtd OD Wd Length FInd 40JJ% rotalFhwedL4wASMj 169.10 ret Flawed Lnlit / , 3I91.1' Ob 93.81 Perent of Total 00 WeOl Ln ahwed 21.01%

Weld 114 0 45 .~~~~~~~~~4-OC LooAlng ODCr 45 Lgaen Down Scan OOCr Scan 45' Scan Scan 45D00Cr 4"0Cr Ligament Lgament Data Files Start Scan End Start End Length Coverage Overap stan End Length TrnModl 1140DI 6.0' 1.16' .OV 12.71 T.7 L7t 6.01' 13.76' 8.7' TflModal 1140211 16.", 26.76' 16.93' 24.73' 6.00 .16' .7r 16.9r 3A4' 20.r TalModal H4026-2 21.01, 30.45 20.01' 3641' 140 16.4r; TrtModal 1405-1 1.0' " g.4' 0.01 ISAI' 1.40 11.46' 13.03 60.01' 126.r 76.01' TrhModel 14063.1 8406' as or 3.43 63' IIAO 1.4 1.43' TtlModal H40711 6.0 14.A' 6.46' 8.36' 16.40' 146 1.4t TnrModal 140914 U.48' 91.91' 513.4' 9.1" 1640' 1.43 AiA' TrtModal H4108-1 911.4'16 1148 86436 115S 184' 13.41' 4.41' TalMtodl 4114-1 111.62' 126.9 1104 126er 1.40' 16.46' Trlmo4al(SC H4161 1647 17.77' t3.6r 111.72 1.05' 7.10 161.6? 170.77' 710' TriModul H41914 11.3' 114.66 162.6 112.01 10.41 11.60' :10? 182.66' 219.85' 37.20' TrlModal H41t14 16.O0' 196.51' 186.01' 16.46' 10.4P' ¶1.50 4.00' TrlModal H41351 192.66' 204.01* 112.51' 202."' ¶0.4V 11.60r 4.00-TrnModal H4206-1 20101 211.51' 200.01' 211.44' 10.41 11.0 *.0 TftModel 14213-1 20446' 210.66' 203.41' 210.3 15.40 16.4t TnlModal H4243-1 236.66 243.6r 234.50' 2460' 14. 16.36' 1.40 234.0' 101.4' 71."'

TilModel H42U-1 243.60' 264. 248.46' 2616' 13.40' 16.46' 1.1 TlModatl H473-1 264.60' 37.3' 21346' 276.3r 16.40' 16.4r 1.45' TFlModl 44288-1 279.60' 214.96' 271.46' 263.90' 1645' 16.6 . 4.4i TrlModal 1421.1 2n1.er 3.481' 210.02' 306.43' 10 16.46' Trlmodal(SC) H4341-3 344.7r 30s.7r 3437' 349.7r 6.05' 7.10' 343.67' 360.r7 7.10 Total 1.4aunt Lemt: MS1 Pler'ntag. of Total Weld Lantb: 5.79%

IsC) a SucUon Cup Scanner REVIEWED PECO NUCLEARf M 1 9 NDE SERVICES RANCHIJ MI-2 99

W.ldH4 Fbw LmngUa Malknuil Flaw Raakhig Through-Faw wm hlWialg AowStw Flaw End Flaw Length LengU S"rch Flaw ThnWAVO Llgamnt Wal Search No. awld Sudace DQ&Densk Helaht' pare ilngbu1) uW LDXne2s) 1QEausk il1Dnihs Urnt I O0 7.79* 11.09 3.30' 56.97 O0Cr 0.10 6.00% 1.90 45 2' NS 00 12.11' 16A0' 3.3a' 5.12 OCr 0.10 6.00%h 1.90 46 3 NS 00 16.59' 18.24' .5' 2.99 ODCt 1.90 48' 4 00 21.06' 22.16' 1.10' 1.99 ODCr 0.10 500%A 1.90 45' 5 NS 00 23.03' 26.6' 3.53 6.39 ODCr 0.10 5.00% 1.90 450 6 OD 25.76' 32.06* 3.30' 6.97 ODCr 0.10 6.00% 1.90 45' S

7 NS OD 33.10' 35.91' 2.76' 4.98 0OCr 0.10 6.00% 1.90 45 a NS OD 61.13' 62.' 1.66' 2.99 0DCr 0.10 6.00% 1.90 45 9 Ns 00 63.33' 6553 2.20' 3.90 OCr 0.10 8.00% 1.90 46' 10 NS OD 657.68 70.58 12.900 23.35 ODCt 0.11 6.50% 1.60 45' 11 NS 00 73.51' 0.10 8.00%

76A3' 2.7f' 4.98 ODCr 0.10 6.00% 1.90 45' 12 NS OD 56.68' 59.98 3.30' 5.9? OCr 0.10 6.00% 1.90 45' 13 NS OD U.58' 98.23' 1.65 2.99 ODCr 0.10 6.00% 1.90 46' 14 MS 0D 104.98' 107.73' 2.75' 4.98 0OCr 0.10 5.00'h 1.90 45' 16 MS 00 IA ' 111.68' 1.10' 1.99 0OCt 0.10 5.00% 1.90 45' NS 00 114.9? 110.12' 3.30' 5.97 ODCr 0.10 5.00% 1.90 45' 17 NS 00 119.22' 120.32' 1.10' 1.99 ODCr 0.10 5.00% 1.90 46' 16 NS 00 126.37' 127.4?' 1.10' 1.99 ODCr 0.10 8.00'k 1.90 46' 19 MS 00 166.20' 167.70' 1.50' 2.72 OCr 0.10 6.00% 1.90 46!

20 NS 00 180.06' 187.71' 1.6S 2.99 00Cr 0.10 6.00% 1.90 45' 21 NS 00 169.910 194.31' 4.40' 7.96 O0Cr 0.10 5.00% 1.90 46' 22 NS 00 194.66' 197.41' 2.7C0 4.98 0OCt 0.10' 6.00% 1.90 45' 23 MS 00 203.81' 209.76' 4.95' 8.90 ODCr 0.10 1.00% 1.90 45' 24 NS OD 235.94' 239.69' 2.75' 4.98 OCr 0.10  : 6.00% 1.90 45' 25 "S Ns 00 244.35' 246.00' 1.65' 2.99 00Cr 0.10 5.00% 1.90 45' 28 NS 0O 248.20' 249.30' 1.10' 1.99 0OCr 0.10 6.00% 1.90 45' 27 NS NS O 263.40' 266.70' 3.30' 6.97 OCr 0.10. .. 0% 1.90 45' 28 MS 00 258.35' 269.41 1.10' 1.99 0OCr 0.10 6.00% 1.90 45' 29 NS 00 260.00' 261.10' 1.10' 1.99 ODCr 0.10 6.00% 1.90 46' 30 NS 00 252.20' 263.30' 1.10' 1.99 00Cr 0.10 6.00% .,1.90 45' 31 NS 00 280.70' 282.70' 2.00' 3.62 0OCr 0.10 5.00% 1.90 45' 32 NS 00 294.93' 298.23' 3.30' 6.97 0OCr 0.10 5.00% 1.90 45*

33 00 298.78* 301.63' 2.75 4.98 OCr 0.10  : .00% 1f90 46' 34 148 0O 305.38' 306.48 1.10 1.99 OCt 0.10 5.00% 1.60 48 35 NS 00 34370 344.70' 1.00' 1.81 ODCr 0.10 .00o% 1.90 45' 3, 00 344.70 345.20' 3.60' 6.34 O0Cr 0.10 8.00%S 1.90 48' 93.81' 169.60 REVIEWE1) PAW Nu MAY1299 NOE SERVICES B iMAY299 'W)94~~~SlI/j99y

LIMERICK-2 SHROUD UT INSPECTION AZIMUTH ZERO (NORTH)

C4

.rl- - .

11 II

.7.4 -

"i--

.7 Ii i}

a eS r.. - . .0

. - .1 .

H5 EXAMINATION AREA ' i

= He u 1 VN5ICrA IN -Ei:i.

=

- ID NDICr I ON _nEL SKETC RELEASE R CORD RFV DATE PRsPsRD Na IMT APPROVED IN PuR 0 03-01-99. R.F R1 SHOUD INPF-CrABlL1Y MYr 1 l 99 R.f. 1fM ~f~t ~

- .~~~~~~~~~~~~~~~~~~~~ SH9ff?0D COVERG I

Weld HS Examo4ton from Ton Side of Weld . 45 &0Q0CrCovuage TOW Scan Lengh EAlned(Deg)i 221.09 Shroud Thickness (In.) 2.00 Toal Scan Lngth Emknd (InJ 399.61 Circumleiee(in.) 650.69 Perce of Wofd Lngslh &wNined 61.41 Inch" perDegree 1.81 Percenl ofE&alned 00 Weld Length FIawed 1.73% rotal Flawed Length (n) 131.06 Percent of Total 00 Weld Lenglh flawed 1.06% rotW Flawed Length (Deg.) 7*41 Percent otEandinedLD Weld Length Flawed 6.17%

Parent of Toa! ID Weld Lnglh Flawed 6.02%

45.00Cr Looing Dowis ODCr Scan 0OCr 46' Scas 46- Scan 45.ODCr 46-ODCr Ligaiawnt Ugaanwii DIel Files Stat Scan Enid Slarn Eid Scan LengUi Coverage Suat Llgwunet Esid Legts Tilodal HIOIILDi .12' 16.57' 5or 11.52' 10.41 11.60 5.07' 39.94' 34.8r ThUwdal H501 OLDI 13.62 24.070 12.670 23.02' 10.46 11.60 4.00' TrModal H6026LD 21.12' 31.67' 20.07' 30.52' 1045' 11.60' 0)

TriMo4al H&33LD1 24.4' 38.94' 23.4 3859' 15.40 16.45' 9)

.4.00' TtiAodal 1505LWD1 51.12' 81.67 50.07 50.52' 10.45' 11.50' 50.07 126.62' 7655' Tugiodail HS063LDI 04.54 64.9 3A.4' 63.94' 10.45 11.50' TiMiodal H5071LD1 52.04 72.490 80.19 71.44' 104P 11.50 4.00' TnModai H5075LD1 69.64' 79.W9 6.49 70.94' 10.5' 11.50' 4.00k I. TilAodal TnMUodA1 TlLmodal Hs6Dt H593WLD1 HI1ILDI 7.

84.4 92.04 87.49 94.98' 102.40 75.99' 53A9 90.9' 16.44 93.94 101.44' 1GA6' 10.46 0.4' 11.50' 11.60' 11.5' 4.00' Ic Troio4a H1OOLDi 99.4' 112.74 98.49 111.69 13.20 14.25 4.0cr TnModal H5IIBLD1 111.12' 128.12' 110.0r 125.47' 16.40' 18.A' TriM oda Trmodal TelModal H51s01 H51s1-1 H5190-1 123.63' 18.08' 192.6r 194.080 198.90' 203.02' 162.680 165.01' 191.52' 193.03' 194.91' 201.97' 10.45' 9.0 10.46' 11.60-10.9P 11.50' i.00' 4 o00I 182.68' 219.33' 30.78' U'

4.0lu TnModal H5208-1 201.W 211.61' 200.01' 210.4' 10.45' 11.60'

.lr TniModal H5213-1 204.49 21.33' 203.430 219.28' 14.854 11.90' TriModal H5243L01 234.4 244.90 233.4?- 243.94' 4.0I

.01' 10.4C 115W 4.00' 233.49* 308.5U' 73.03

.1?' LU TrlModal H6261LP1 242.040 262.490 240.9sr 211.44 10.46 11.50- .%

~z TntModal H62LD1 249.54 259.69 248.41 268.94 10.49' 11.60 TtModal H6266LD1 257.e4 267.49' 156.i9 266.44 10.45' 11.600 TrlModal H6273LD1 264.5 274.99 203.49 27194 10.45' 11.60 10.0' w:t TelModad H28lILD1 272.04' 282.49 270.9r 281.44' 10.45 11.60' C5 TntUodal H628&LD1 279.W4 292.74' 278.4s 291.9' 13.20' 14.26 H52s6LD1 291.12' 308.62' 290.07' 305.47' 15.40' 16.45 323.120 Total Ugamel, LengtU: 221.09' 221.09' Patcentag of Toal Weld Length: 41.41%

I I ,

LJ - t ULJLI,,/ s,L LI9f

Weld H5

. Inside Surface Flaws Outside Surface Flaws Through- ThrorQgh-Sizing Wall Search Sizing Waill Search No.: Location Height Unit Location Helght Unit 1 69.42 <0.05 S0 1 77.84' <0.065 45.

2 8.96 <0.05 00 2 84.04 <0.05: 45.

3 78.39' c0.05 60' 4 92.09" <0.05 60 5 93.74' <0.05 60' 6 98.14' c0.05 60 7 99.79' c0.05 60' a 111.72 (0.06 60' 9 122.17' (0.05 60 10 123.82 <0.05 60 11 183.11 c0.05 60' I

REVIEWED PECO NUCEA*% MY 1 219 II NDE,SERVICES BRANCH I

Weld H6 Flaw Flaw Flaw Weld Initiating Flaw Start Flaw End Length Length Search No. Side Surface LDeareesi (Dearees) (DOgrees) (Ies) Unit I NS ID 68.44' 59.97, 1.53 2.77 450 2' NS ID 77.01' 80.31' 3.30'

  • 5.97 45*

3 NS OD 77.290 7a.36' 1.071 0DCr 4 NS 0D 83A9 86.25' 2.76' B.97 ODCr a NS ID 90.918 94.76* 3.865 4.98 45.

65 NS ID 97.61 100.26* 2.76 . 6.03 45' 7* NS ID 100.49' 112.82- 3.33 0803 45 8 NS ID 121.620 123.82' 2.20- 3.98 45.

9 NS ID 1B3.11' 184.21' 1.106 1.99 45a Total Flaw Lngth at inide Surface: 18.06' Total Flaw Length at Outside Surface: 3.83'

'FlIaw datectid In adjacent overiapping scans I,

i REVIEWED PECO NUCL AWAYMY 12'99 NDE SRVICES BRA?4C 94 //v?f 5-n

1 LIMERICK-2 SHROUD UT INSPECTION AZIMUTH ZERO (NORTH)

-L WU r

.k. '^t I"I = *.: I . *_:;.

-t, J

  • /.

'1/

j. As

\'-;~~/1 a

.a-

.t;w-~9~

t...

i II M-t tI

~~_

P_ \ i

--- J=

'd_'~~~~'I t i

19 H i INDICATION REAS SKETCH RELEASE RECORD D -RaEyEWEDIR

1- .E PURPOSE 03-1-99 R.F. GRZZ ISHRO SPEA8EcLrY SUDY

=04-11-99 R.f. GtZU _ M1RUD COVOtAGE'

Weld H6 gxatniiialion from Haltom Side of W/d 45 &ODCr Coverau ToaUl Scan Lengat Exauund egOgJ214.21 Shroud Thickiies (An.) 2.00 Tot Scan LWiUI Examlod (i.) 346.69 C(lcaun)rcO (h.J 630.67 pamienl of Weld Length EuMned 0.00% !nch per D.gf,o 1.76 Pwcent of lxwaned 10 WWd Legth FlAea 4.9% . TOW Fliwed Len gif (lnJ 242.90 Poicent of ToW ID Wld Length FLBwOd 31.6% Totl FlAwd Length (0.gJ 138.80' Looking 4S° ODCr Up Data 45U Scan Scan Scall ooCr Scan 4S-ODCr 45.00Cr LlQalWnt Ligaallant Ligauuion Files Stare Enld Start Scan End LvngUI Cov.1age Overlap Slar End Lefnrg TelMoal higiLUI 6.09' 16.64' 6.04 15.4I 10.46' 11.610 4.00' 5.04 339.360 34.3r TelModal H601tLU1 13.6V 24.04 12.64' 22.99' 10.4'6 11.50' 4.00 TrMal H6026LUt 21090 31.64' 20.04' 30.49 10.45' 11.60' 6.08' TeModl H6033LD1 24.61' 39.36 23.46' 3.31' 14.81' 15.90 TlMAodel HiGOLUI 51.09 614* W.04' 60.49' 10.45' 11.5f 11.60' 60.W4 126.49 76.46 MtiDul H6063LUI 61.U9- 61.64 60.044 t0.49' 10.45' 11.50 0.65 TflMo H6071LU1 62.01. 72.46 40.96' 1 .41 10.46' 11.50' 4.00.

TelMoal H6078LUl 69.61- 79.96 68.460 - 76.91' 10.46 11.60 4.000 TelModal H6QO6LUI 77.01' 57.46' 7I4 6.410 10.46' 11.60 4.00 Tltaodai H9SLUI 14.61' 94.95' 53.46' 391' 101A6 11.50. 4.00' TtlModal digiIUI S2l1' 1044' 90.96* 191.41' 10.46' 1t600 4.00 9.40' 111.t1 12.6' 13.700 2.12' 0)

TelModal H610BLU2 90.61' 112.16' TilMoal H616LUR 111.00W 126.49' 110.04 126.44' 1640 16.45' (

TelModal h191.0 183.71- 193.61' 152.066 102.56' 9.9 10.96 5.6r 12.6 219.36' 36.70' .4 TillMdl H6191-1 18609' 196.64' 186.04' 195.49 10.46 11.W 3.00' Trtodal H619LUI 194.59 205.04' 193.64' 203.99' 10.45' 11.50' S.00' TlModal HC206LUI 201.09' 211.64 200.046 210.49' 105* 11.60' 5.08, TtModal h6213LU1 204.51' 219.36' 203.46 218.31' 14.861 15.90' TnModI H6243LUI 236.69' 247.47' 237.64' 246.42' 5.8d' 9.93' 6.61' 237.64' 304.29' 66.76 TnModal HS1LUI 242.01' 262.46 240.68 261.41' 10.45* 11.60 4.00' TelModal tiI2LUI 249.61' 2i.96' 24.46' 2M 1 10.46' 11.60 4.00' Telodal $6266LU1 257.01' 267.46' 255.98' 2(6.41' 10.45 11.50. 4.00' .

tlModal fW273LU1 264.51' 276.04' 263.46 273.99 10.63' 11.58 4.01' TelMoal h62IOILUI 272.01' 282.46* 270.96 201.41' 10.46 11.50' 4.o0' Te.oa 16285LU 279.51' 292.71' 27.46' 2S1.66' 13.20* 14.25' 2.67'  ; .

TelModal H6296LUi 291.09' 304.2' 290.04' 33.24' 13.20' 14.25' cl w

358.330 104.12Ir0.

Tol Scanwd: 31b.33' Owtlap: 104.12 Ttal Uganet LsigAlU: 214.21' Nel CoeiinaB: 214.21S as"%

Petagatage W Wowaciuu", F4iasmagv atoTota Weld LwigtUl: 69.60%

r[t;a' II1-lS'/{_L/1*/

Flaw Flaw Length Flaw Weld Initiating Flaw Start Flaw End Length Length Search No. Side Surface (Degees (Degrees) fgQree) finches) Uilt 1^ MS ID 6.09' 21.84 15.75' 27.56 45.00' 2* NS ID 22.19' 39.36' 17.17' 30.05 :45.00 3' NS ID 5109- 63.11' 12.02' 21.04 45100' 4- NS ID 65.86 68.61' 2.75' 4.81 45000 6^ NS ID 69.16' 79.76 10.60' 18.55 46.00' 6 NS ID 82.51' 88.3B' 6.85' 10.24 45;00' NS ID 91.11. 93.86' 2.75' 4.81 4.00 8- NS ID 92.01' 96.950 4.95' 8.66 :45'00-9^ NS ID 97.51' 123.19' 25.88 44.94 45.000 10* NS ID 187.74- 193.24' 5.50 9.63 45.00' 11' NS IO 204.390 205.49' 1.10' 1.93 45.00' 12' NS ID 209.34' 214.41"' 5.07 8.87 '45l00' W3' NS ID 215.51' 219.36' 3.855 6.74 45.00' 14' NS ID 238.59' 239.69' 1.10' 1.92 45.00' 15' NS ID 246.31' 247.39' 2.08' 3.64 -45.00 16 NS ID 248.06' 250.26' 2.20' 3.85 45.00' 17' NS ID 262.51' 265.26' 2.75' 4.81 45.00' 18* NS ID 275.31' 276.96 1.65' 2.89 45.00' 19' NS ID 283.91' 294.94' 11.03' 19.30 45.00' 20 MS ID 296.04' 298.24' 2.20' 3.85 45.00' 21V NS ID 301.54' 304.29' 2.75 4.81 49.00' Total Degrees; 138.80' Total Inches: 242.90 REVIEWED PECO NUCLEAR12 NOE SERVICES 7/- -ACI+"

Weld H6 lilde Surface Flawv LocaUon Through-Wall Height Location Through-WaU Height 1 7.79' 0.08 32 103.96 0.23 2 9.99' 0.07 33 105.06 0.16 3 12.74 0.06 .34 107.268 0.17 4 14.39' 0.06 35 111.69 0.18 6 16.398 0.06 36 113.34 0.17 6 19.14' 0.06 37 117.74' 0.24 7 20.24' (0.05 38 119.94- 0.19 8 23.89' 0.10 39 188.89' 0.21 9 25.54' O.08 40 191.640 0.27 10 29.39' 0.15 41 192.74' 0.35 11 30.060 0.15 42 204.94' <0.05 12 31.63' 0.21 43 210.49' 0.26 13 37.21t 0.17 44 211.25' 0.28 14 51.14' 0.16 45 212.0' 0.20 15 52.24' 0.27 48 217.03' 0.15 116 53.85 0.29 47 239.19' 0.07 17 52.24' 0.23 48 245.36' 0.05 18 54.99' 0.14 49 250.111 c0.05 19 58.84' 0.23 50 263.6' 0.27 20 81.51' 0.22 51 264.66- 0.19 21 67.01' 0.19 52 275.91' 0.30 22 70.86' 0.18 53 285.61' 0.20 . I 23 73.98' 0.24 54 286.71' 0.27 i !

24 76.16' 0.20 58 288.368 0.28 I 25 83.11' c0.05 58 289.46' 0.28 226 14.76' 0.12 57 292.21' 0.28 217 86.76' 0.10 58 293.89' 0.16 t  :

28 93.88' 0.27 59 297.19' 0.16  : I 29 95.91' 0.24 60 302.69' (0.05 30 98.66 0.18 31 100.66' 0.28  : I RIEVLEWED lpfCO NUCLEIA 1U9 NDE SERlVICE8 Q3RANC WI,,, v9WW.4' 5///9

Weld 17 Total Scn Length Exandned D(0" 212.74' Shroud Thickness (in) 2.00 Tote Scan Length Exemlned lnJ 3T263 CircwnunwcM (in.J .130a57 Petcent of Weld Longth Examined SS.09% inches per Degree 15?

Percent of Examtmed Weld Length Flwed 0.0%

Pcrent o( Total Weld Length Rawed 0.0%

Loahi g ODCr 45' AmousNt Overall Dowi Data OCrSc8e Scat Scat 46' Scaw of Scan Scana 465.0Cr 4&DDCr Lla,nt Ligament LlgalNesrt Fies Stalt End Start End Overlp Scan Length Length Covrge Overlap Start Etid Length TnModal 170111.01 6.06' 21.485 5.03' 20.43' 15.40' :eS 6.53' 5.032 36.42' 31.39' TriMoosI 11702611 17.000 22.0- 15.95- 21.4' 0.50. 6.5S 2.47' TriModel H70261LD2 21.06 3.42' 20.03' 31.370 15.34' 14.39' H7041LOt Not Scaed H7046LD1 Not Scanwnad TniModel H7063L01 54.50' 00.90 53.45 es.ts 15.40' 1546' 1.45 53.4' 126.46'

. r3.03' TflModel H7076101 150- 84.00 6.45' 83.81 I540

  • 16;5 1.460 Tuto" 17093LD1 64.50- 9,.900 83.4' 96.6 ISAO' :1E46' 1.45' TtlMoeFl 1710LD1 39.60' 114.90' 08.45' 113.86' 15.40'. 16,45- 4.07' TnModal 7116LDt 111.0' 126.40' 110.030 j25-43' 15.400 1445' h7123L1 Not Scanlnd Ht13LD1 Not Scainned TiModal H71V11D1 166.06' 20.4' 181.03' 200.43' 15.40' 16 45' 145' 185.03- 216.48' 31.45 TlMoMdal H7206101 201.00 216.40' 200.03- 215.43 1.46' 16:45' H7221LD1 Nut Scailad .:

H7236LD1 Not Scannied TdlMosta H7243LD 238.65' 24.67' 234.60' 246.32' 14.32' 1537' 1.42' 234.50' 311.36' 78.48' TrMod.I M72G1LO1 240.50' 264.05' 246.45' 263.90' 15.45' 1 1.600 TrINMl H7273L1 244.50' 273.05' 263.45' 276.30' 15.45 1660 1.50' TnModel 117268101 279.60' 294.950 276.45' 293.00 15.45' 16:0 4.32' TrtModal H7296LDt 291.080 306.13' 290.03 305.43' 15.45' 160- . 6.40-TriMadel H7303LD1 301.18 311.36' 300.13 310.33' 10.20 . 1t25 M7355LD1 Not Scasnmud 24f.11' 34.37' Total Scaninwd: 247.11' Ovenl*p: 34.37  ; TtlLgnnt Lag 212.74' Not Coverage: 212.74 45.0Cr Cova go:

Purcentage ot Wild Scanned: 59.09% 45-00Cr Ovelrlp: Pecantage o Total Weid LengU: s  %

O4500CrNet Coverage:

REiEWED PECO NUCLEAVR;v , /

ND SAVICS BC 1 299 9 9 ,Sl

NIS-1 2R07 Section 3 Summary of ASME Section Xl Repairs and Replacements Performed During Cycle 7 April 21, 2001 to March 23, 2003

I I NIS-1 2R07 Section 3 Page 1 of 3 Summary of ASME Section Xl Repairs and Replacements Performed During Cycle 7 SYSTEM 011 EMERGENCY SERVICE WATER R0800943 011-2012, replaced 8" check valve disc.

SYSTEM 041 NUCLEAR BOILER R0900518 041-2F010B, Feedwater check valve inspection; replaced valve disc.

R0869133 PSV-041-2F013A, Replaced MSRV body with reworked body SIN 180 and pilot SIN 016.

R0868142 PSV-041-2F013B, Replaced MSRV body with reworked body S/N 175 and pilot S/N 021.

R0869139 PSV-041-2F013C, Replaced MSRV body with reworked body S/N 150 and pilot S/N 022.

R0869138 PSV-041-2F01 3D, Replaced MSRV body with reworked body S/N 190 and pilot S/N 017.

Repaired inlet flange by welding.

R0868115 PSV-041-2F013E, Replaced MSRV body with reworked body SIN 176 and pilot S/N 029.

R0869044 PSV-041-2F013F, Replaced MSRV body with reworked body S/N 174 and pilot S/N 027.

R0869049 PSV-041-2F013G, Replaced MSRV body with reworked body SIN 193 and pilot SIN 015.

R0869131 PSV-041-2F013H, Replaced MSRV body with reworked body S/N 170 and pilot S/N 018.

Repaired inlet flange by welding.

R0869137 PSV-041-2F013J, Replaced MSRV body with reworked body SIN 181 and pilot S/N 040.

R0869129 PSV-041-2F013K, Replaced MSRV body with reworked body S/N 148 and pilot S/N 020.

R0869135 PSV-041-2F013L, Replaced MSRV body with reworked body SIN 151 and pilot SIN 025.

R0864454 PSV-041 -2F01 3M, Replaced MSRV body with reworked body SIN 189 and pilot S/N 023.

R0864209 PSV-041-2F013N, Replaced MSRV body with reworked body S/N 147 and pilot S/N 024.

R0869130 PSV-041-2F01 3S, Replaced MSRV body with reworked body S/N 169 and pilot S/N 030.

SYSTEM 053 FUEL POOL COOLING C0193967 GBB-210-1. Installed high point vent.

SYSTEM 044 REACTOR WATER CLEAN-UP C0204536 HV-044-2F039, Replaced valve.

NIS-1 2R07 Section 3 Page 2 of 3 Summary of ASME Section Xl Repairs and Replacements Performed During Cycle 7 SYSTEM 047 CONTROL ROD DRIVES R0867313 20-S299-06-35, Replaced CRD at reactor core location 06-35.

20-S299-1443, Replaced CRD at reactor core location 1443.

20-S299-18-35, Replaced CRD at reactor core location 18-35.

20-S299-22-1 1, Replaced CRD at reactor core location 22-11.

20-S299-22-15, Replaced CRD at reactor core location 22-15.

20-S299-22-51, Replaced CRD at reactor core location 22-51.

20-S299-26-07, Replaced CRD at reactor core location 26-07.

20-S299-30-59, Replaced CRD at reactor core location 30-59.

20-S299-34-03, Replaced CRD at reactor core location 34-03.

20-S299-34-07, Replaced CRD at reactor core location 34-07.

20-S299-34-1 1, Replaced CRD at reactor core location 34-11.

20-S299-38-23, Replaced CRD at reactor core location 38-23.

20-S299-38-59, Replaced CRD at reactor core location 38-59.

20-S299-42-19, Replaced CRD at reactor core location 42-19.

20-S299-42-51, Replaced CRD at reactor core location 42-51.

20-S299-46-27, Replaced CRD at reactor core location 46-27.

20-S299-46-51, Replaced CRD at reactor core location 46-51.

20-S299-5047, Replaced CRD at reactor core location 50-47.

20-S299-58-35, Replaced CRD at reactor core location 58-35.

SYSTEM 048 STANDBY LIQUID CONTROL R0891800 XV-048-2F004C, Replaced inlet fitting trigger body.

SYSTEM 051 RESIDUAL HEAT REMOVAL C0194970 2B-E205, Installed tube plugs and seal welded. Replaced bottom head studs and nuts.

C0203362 HV-051-2F050B, Replaced 12 check valve disc.

C0204446 HV-051-2F050A, Reworked valve internals; weld repair disc post.

I I I NIS-1 2R07 Section 3 Page 3 of 3 Summary of ASME Section Xl Repairs and Replacements Performed During Cycle 7 R0724582 051-2F090D, Replaced check valve disc.

R0863913 051-2F090C, Replaced check valve disc.

R0896042 051-2F089D, Replaced check valve disc.

SYSTEM 052 CORE SPRAY C0194544 PSV-052-2F032A, Test and replace relief valve.

R0871833 052-2F030B, Replaced valve and adjacent pipe.

SYSTEM 057 CONTAINMENT ATMOSPHERE CONTROL R0872422 PSV-057-237B-1, Plug weided and re-drilied orifice plate hole.

SYSTEM 103 SNUBBERS Al 361522 DCA-201-H060, Replaced mechanical snubber with SIN 42198.

A1361523 EBB-209-H015, Replaced mechanical snubber with SIN 42196.

GBB-217-HOI 5, Replaced mechanical snubber with SIN 42203.

GBB-219-H093 (B), Replaced mechanical snubber with SIN 42213.

HBB-210-H021(A), Replaced mechanical snubber with SIN 42197.

HBC-293-HO12, Replaced mechanical snubber with SIN 41413.

Al 361529 GBB-213-H013(A), Replaced mechanical snubber with S/N 42195.

GBB-213-H013(B), Replaced mechanical snubber with S/N 41840.

GBB-213-H054, Replaced mechanical snubber with S/N 42209.

GBB-219-H059(A), Replaced mechanical snubber with S/N 42218.

GBB-218-H064, Replaced mechanical snubber with S/N 42215.

GBB-218-H068, Replaced mechanical snubber with S/N 42217.

GBB-218-H069(B), Replaced mechanical snubber with SIN 41839.

GBB-218-H078(A), Replaced mechanical snubber with S/N 42216.

GBB-218-H078(B), Replaced mechanical snubber with S/N 42210.

GBB-219-H012, Replaced mechanical snubber with S/N 42214.

GBB-219-H090(B), Replaced mechanical snubber with S/N 42219.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Comnany, LLC Date May 9. 2003 Narne 200 Exelon Way, Kennett Square. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0800943 Address Repair Organization P.O. No., Job No. etc.
3. Work Pertormed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoa2. PA 19464-230 Expiration Date N/A Address
4. Identification of System Emeroency Service Water (System 011) Line No. HBC-268 Valve 011-2012
5. (a) Applicable Construction Code ASME ll 1971 _ Edtion. Summer 1971 Addenda. N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements I e9
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 8 Valve
  • 114-77495 011-2012 Anchor/Darling Heat# 8335 N/A PO# 257805- 1996 REPLACEMENT YES Disc SIN 3 348029
  • raceability per Exelon stock code number. _ _
7. Description of work: Valve disc reglaced.
8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure m:

OtherOD 5 _psi TestTemp. N/A 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In.x 11 in., (2) informa-tion in items I hrough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/E2) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

IlI I W/O No. R0800943 Sheet 2 of 2 FORM NIS-2 BACK)

9. Remarks Manutacturer's data reports are traceable by Exelon work order ackaoe.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDlacement conforms to the rules of the ASME Code.Section XI (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed OwnersDese .Hr Date May9 ,2003 O& or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a varid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owner's Report during the period I 9 T 7 o ;' to 12.. , ixr 3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner s Report. Furthermore, neither the Inspector nor his employer shalt be liable in any for any personal injury or property damage or a loss of any kind arising from or connected with this fner inspection.

~-*~e' &>$ Commissions PA-2497 I.N & A Inspectors Signature National Board, State. Province, and Endorsements nate /Z CTa4h qZOoAq (12i82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requited by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Comanv. LLC Date May 5. 2003 Name 200 Exelon Way. Kennett Square. PA 19348 Sheet I of 2 Address
2. Plant Limerick Generatina Station Unit Name P.O. Box 2300. Sanatopa PA 19464-2300 Work Order No. R0900518 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Date NIA Address
4. Identification of System Nuclear Boiler. Feedwater .

(Svstem 41)

Line No DLA-206 Valve 041.2FOInR

5. (a) Applicable Construction Code ASME IIl 19 71 Edition. Winter 1972 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1 9j.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manutacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

__________ _________ __________ ~~~~~~~~~~~~~~

24 Valve Atwood 8 Heat# R4270/3 N/A

  • 114-98541 041-2FOOB Morrill Trace# 15892 PON 257796- 2001 REPLACEMENT YES Disc S/N 1 348103 Traceabilily per Exelon stock code number.
7. Description of work: Valve disc replaced.
8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure dZ Othero 1045 psi TestTemp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion in items 1 through 6 on this reporl is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I I W/O No. R0900518 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturer's Data Rerrts are traceable bywork order package.

Applicable Manufacturer's Data Reports to be attached Retet to Exelon design chance ECR-LG-94-06839 for changes from original design.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code. Section Xl. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed A ,

rier or Owners D

6esignee, Title T J.H. Kramer (engineer} Date MayS. ,2003 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a varid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pefnstyvania and empbyed by HSBCT of have inspected the components described in this Owners Repor during the period 2, AQ6 O2. to is E-AY 0:3 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising foM or connected with this inspection.

________________________________ -_ Commissions PA-2497 I N &A Insp tor's Signature National Board, State, Province, and Endorsements Date  ; 4rXzCC1Z13 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 200 Exelon Way. Kennett Sauare. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatona. PA 19464-2300 Work Order No. R0869133 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300 Sanatoa PA 19464-2300 Expiration Date N/A

-Address

4. Identification of System Nuclear Boiler (System 041) Line Nc. APE-2MS PSV-041-2F013A
5. (a) Applicable Construction Code ASME ll 1968 Edition. Summer 1970 Addenda_ N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 j,9
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)

MSRV PILOT TARGET 016 N/A

  • 114-18880 NiA REPLACEMENT YES ASSEMBLY ROCK PO# I8X53 MSRV BODY TARGET 180 N/A  ; 141880 N/A REPLACEMENT YES ROCK P#105 MAIN DISC TARGET 4600 N/A
  • 114-76023 _ REPLACEMENT l ROCK PO# 180253 20 ELCMN E
  • Traceability per Exelon Part Code Number.
7. Description of Work: Replaced main steam relief valve main body with reworked body No.180 and pilot No.016
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure E)

Other _ Pressure 1045_PSi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or dravings may be used, provided (1) size 8 12 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sh"t is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0869133 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturers Data Reports are traceable by Exelon Work Order package.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section X. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer, Enaineer Date June 3. ,2003

(*ne or wtSsDesignee, Ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owners Report during the period iI 'ap 0 to IA E6 Os , and state that to the best of my knowedge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his empyer shall be liable in any manner for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection.

rs *ig~ CsCommissbns PA-2497 I.N S A Inspector's Sinature National Board, State, Province, and Endorsements Date_ _ _ 1tt J4.t- Mr g (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner LcISrwn WInalIkn. LLLA rPI. Date June 3. 2003 Name 200 Exebn Wav Kennett Sauare. PA 18348 Sheet 1 of. 2 Adaress
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatooa, PA 19464-2300 Work Order No. R0868142 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanaloga. PA 19464-2300 Expiration Date N/A Address
4. identification of System Nuclear Boiler (System 0411 Line No. APE-2M5 PSV-041-2FO13B
5. (a) Applicable Construction Code ASME III 196 ._ Edition. Summer 1970 Addendaa. MMl, MI^ ~ .vut

%lobe (b) Applicable Editon of Section Xl Utilized for Repairs or Replacements 19 8

6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial Natiwl Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or MSRV PILOT TARGET 021 N/A
  • 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK POW 180253 MSRV BODY TARGET 175 N/A PO 180253 N/A REPLACEMENT YES ROCK PW105 Traceability per Exelon Part Code Number.
7. Description of Work: Replaced main steam relief valve main body with reworked body No.175 and pilot No.021
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure i Other _ Pressure j045_psi TestTemp. 16 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R08681 42 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks None.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed n . . .Karnr1 En ineer Date June 3. .2003 Oner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owner's Report during the period *)rP C __ to 5 .1)AJT O. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken correcte measures described in this Owner's Report in accordance with the requirements of the ASME code,Section XI.

Dy signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repott. Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

G9 m m is si o n~~~~~~~misios PA-2497 IN A InspedorSm s nature National Board, State, Province, and Endorsements Date t3 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3.2003 Name onVLU.Coln AcTUjI I

Z/VYFC.I1 t --- C-----

CU MA 1Q2C

. FM. l Sheet 1 of g. , ._

Address

2. Plant Limerick Generatina Station Unit _

Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0869139 Address Repair Organization P.O. No.. Job No. etc.

3. Work Pertormed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Nuclear6Boiler fSs!te n .. ___- LineNo. APE-21VS5 PSV-041-2F013C
5. (a) Applicable Construction Code ASME Ill 1968 Edition, Summer 1970 Addenda_ N/A _Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or MSRV PILOT TARGET 022 N/A
  • 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 150 NIA 1 8S253 N/A REPLACEMENT YES ROCK P#105 Traceability per Exelon Part Code Number.
7. Description of Work: Replaced main steam relief valve main body with reworked body No.150 and pilot No.022
8. Tests conducted: Hydiostatic Pneumatic Nominal Operating Pressure Other _ Pressure 1045 psi Test Temp. 168 'F.

NOTE: Supplemenlal sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 In. x 11In., (2) informa-tion in items 1 through 6 on this repot is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

Il lI W/O No. R0869139 Sheet 2 ol 2 FORM NIS-2 (BACK)

9. Remarks None.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules o1 the ASME Code. Section Xi. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed .1J . J.H. Kramer. Engineer Date June3 , 2003 wner or Owner s Designee, Ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvivania and employed by HSBCT of Hartford. CT have inspected the components described in this Owners Report dwing the period i / 5I4 Cz lo 1-3 *TLrA C - andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, nether the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising trom or connected with this inspection.

Commissions PA-2497 L.N 8 A Inspectors Signature National Board. State. Province, and Endorsements Date /3 & v.4:- z 3 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name Inn Flnn Wvn nneltt Snuare PA 14E Sheet 1 of Address
2. Plard Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoa. PA 19464-2300 Work Order No. R0869138 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A Pt). Box 2300. Sanatoa. PA 19464230 Expiration Date N/A Address
4. Identification of System Nuclear Boiler (System 0411 Line No. APE-2MS PSV-041-2F013D
5. (a) Applicable Construction Code ASME III 1968 Edition. Summer1970 Addenda,, N/A -Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 B9.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification . Replacement Stamped No. (Yes or MSRV PILOT TARGET 017 N/A 1114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 190 N/A 114-18879 N/A REPLACEMENT YES ROCKPol105 Traceability per Exelon Part Code Number.
7. Description of Work: Replaced main steam relief valve main body with reworked body No.190 and vilot No.017
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure 3 Other _ Pressure 1045_ Dsi Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the nu:nber of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

WIO No. R0869138 Sheet 2 of 2 FORM NIS-2 BACK)

9. Remarks Relief valve inlet fiange recaired by welding under Exelon work order C0203435.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this eozasemern conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer, Encineer rDate

._*s June 3 oR _ . w .~---

2m

()wner or Ownees Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford. CT have inspected the components described in this Owners Reporlt during the period 1/ , ,A.J to aZ Tl3Js O, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in hiS Owners Report in accordance with the requienents of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concernin the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employet shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i n s p e Commissions PA-2497 I.N 8 A Inspectors Signatue National Board, State, Province, and Endorsements Datf J3 Iw' ;a4oc (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 200 Exelon Wav. Kennett Souare. PA 19348 Sheet I of 2 Address
2. Plant Lirmerick Generating Station Uni 2 Name P.O Box 2300. Sanatooa PA 19464-2300 Work Order No. R0868115 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatopa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Nuclear Boiler (Srstem 041) - ,inelto. A 2Ms PSV-041-2F01 3E
5. (a) Applicable Construction Code ASME III 19_68_Edtion. Sumrner 1970 Addenda,. N/A -Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)

MSRV PILOT TARGET 029 N/A

  • 114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 176 N/A
  • 114-18879 N/A REPLACEMENT YES ROCK _

Iraceability per Exelon Part Code Number.

7. Description of Work: Replaced main steam relief valve main body with reworked body No.176 and vilot No.029 B. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure@

Other _ Pressure 14Q psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12J82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

I I W/O No. R08681 15 Sheet 2 of 2 FORM NIS-2 4BACK)

9. Remarks None.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certity that the statements made in the report are correct and this redlacement conforms to lhe rules of the ASME Code.Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ( n_V. V_, J.H, Kramer Encineer Date June 3 .2003 0wner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford CT have inspected the components described in this Owner's Report during the period 4 A 4z rP to a ; JVAA5 £3 _, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinatons and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or properly damage or a loss of any kind arising from or connected with this inspection.

Commissions PA-2497 I N & A Inspector's Signature National Board, State, Province, and Endorsements Date /3 O&Al W2 o'3 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 900FEln n Wav knnett aunare PA 134 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit -

Name P.O. Box 2300. Sanatoga PA 19464-2300 Work Order No. R0869044 Address Repair Organization P.O. No., Job No. etc.

3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatona. PA 19464-2300 Expiration Date N/A Address
4. Identification of Svstem_Nuclear Boiler (System 041) Line No. APE-2MS PSV-041-2F013F
5. (a) Applicable Construction Code ASME ll 19-68 Edition. Summer 1970 Addenda ,,fl MIA r^

%It wt Case (b) Applicable Edition of Section Xl Jtilzed for Repairs or Replacements 1989

6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Bult Replaced, or Code Comnponent Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)

MSRV PILOT TARGET 027 N/A 114-18880 NtA REPLACEMENT YES ASSEMBLY ROCK po 10253 MSRV BODY TARGET 174 N/A 114-18880 N/A REPLACEMENT YES ROCK PO# 180253

  • Traceability per Exelon Pat Code Number.
7. Description of Work' Replaced main steam relief valve main body with reworked body No.174 and Dilot No.027
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure 3 Other _ Pressure j1W5 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1f2 in. x 11 in., (2) informa-tion in items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W1O No. R0869044 Sheet 2 o 2 FORM NIS-2 IBACK)

9. Remarks None Applicable Manufacturers Data Reports to be attached CERTIFICA1E OF COMPLIANCE We certity that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Syrnbol Stamp NA Certificate of Authorization No. NA Expiration Date NA

_ .s s

Sine

>n - ....

(0 ...

'o J.H. Kraffer- Encineer Date June 3. . 2003 aUnve- or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boilr and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT have insrvected the components described in this Owner's Report during the period 1/ , O= to l 7LAJI QC. .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his emplyer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising Irom or connected with this inspection. > ,<-7 ,

Z, ,/ w 1Commissions, PA-2497 I N & A Inspectoes Signature 7 National Board. State, Province, and Endorsements Date te. L L .7 A O C 5 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatino Station Unit 2 Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0869049 Address Repait Organizalion P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. NA P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Nucear Boiler (SVStem 041) Line No. APE-2MS PSV-041-2F013G
5. (a) Applicable Construction Code ASME Ill 1968 EdRtion. Summer 1970 Addenda. N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19,o9
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Reptacement Stamped No. (Yes or No)

MSRV PILOT TARGET 015 N/A

  • 114-18880 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRVBODY TARGET 193 N/A
  • 114-188 N/A REPLACEMENT YES ROCK PO# 180253 MAIN DISC TARGET 4550 N/A P114-6023 1992 REPLACEMENT YES ROCK PO# 353s i MAIN SEAT TARGET 55 NIA I 4-76024 N/A REPLACEMENT NO MAIN~ ~~RCKPO# 204066-ROCK ~~~~~~ ~~348080 (1) 1 HEAT No. 13350 N/A TARGET SPLINE U.S. BOLT Trace No. IWE ROCK PART N/A REPLACEMENT NO BOLT No. 204842-2 (1) 1-1/8" ENERGY HEAT No. 2-347ILC N/A TARGET SPLINE STEEL LOT No. CEY5 ROCK PART N/A REPLACEMENT NO NUT No. 204843-1 Traceability per Exelon Part Code Number.

- nA-ert nf IQa;o*

OA' 0-n-L m i nDI;-#

- .- -nlb -iths, -- G-_ EA l 910<

Nn-& --n  ;-

nilnt r.n4 C

1. uesnpllopI w v,VW... ne.- llllwea elI valv- -. tn *ew'rWe uuuy m.~ :lo n l .1- .
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure 3 Other - Pressure j_045_psi Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) informa-tion in Items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0869049 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturers Data ReDorts are traceable by Exelon Work Ordet gackage.

Applicable Manufacturees Data Reports to be attached CERTIFICATE OF COMPLIANCE We certity that the statements made in the report are cofrect and this redlacement conforms to the rules of the ASME Code, Section Xl. repair or replacement

'rype Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed i ) . L J.H. Kramer. Engineer Date June 3. - 2003 er owners Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a vaid commisslon issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ot Pennsylvania and employed by HSBCT of Hartford. CT - have inspected the components described in this Owners Report during the period 5 C ti to / Zr kiE 03 , andstatethat to the best of my knwledge and belief, the Owner has performed examinations and taken corrective measures described in this owner's Report in accordance with the requirements of the ASME code, Section Xi.

By signing this cerlificate neither he Inspector nor his employer makes any warranty, expressed or Implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

missions PA-2497 IN a A InspeorhS Signatwe / National Board. State, Province, and Endorsements Date-.  :

U4i (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name ttfnl rACPI*- VVCV INCIL.....CA 40C*A Sheet I of 2 Address
2. Plant Limerick Generating Station Unit

. Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0869131 Address Repair Organization P.O. No., Job No. etc.

3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanalogaa PA 19464-2300 Expiration Date N/A Address
4. Identification of SystemNuclear Boiler (Svstem 0411 Line No. APE-2MS PSV-041-2F013H
5. (a) Applicable Construction Code ASME Ill 1968 Editon, Summer 1970 Addenda N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_8
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Buitt Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or

. __ __ _ __ __ __ _ _ ___ __ ___ N o)

MSRV PILOT TARGET 018 N/A 114-03966 N/A REPLACEMENT YES ASSEMBLY ROCK po# 180253 MSRV BODY TARGET 170 N/A 11403566 NIA REPLACEMENT YES ROCK P#105 (2) 1-1/8- HEAT No. 13350 N/A TARGET SPLINE U.S. BOLT Trace No. 1WB ROCK PART N/A REPLACEMENT NO BOLT No. 204842-2 (2)1-1ro ENERGY HEAT No. 2-3471LC N/A TARGET SPLINE STEEL LOT No. CEY5 ROCK PART N/A REPLACEMENT NO NUT No. 204843-1

  • raceability per Exelon Part Code Number.
7. Description of Work: Redlaced main steam relief valve main body with reworked body No.170 and vilot No.018 S. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure 3 Other _ Pressure _145__psi Test Temp. 168 F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8112 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I -I I W/O No. R069131 Sheet 2 of 2 FORM NIS.2 (BACK)

9. Remarks Reief valve inlet flange repaired by weldina under Exelon work order C0204049.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reDacement conforms to the rules of the ASME Code.Section XI. repair or reptacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signe ned o. HK Enaineer ramer Date June 3. ,.2003

{U wne o wner's Designee, Tittb CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT .have inspected the components described in this Owners Report during the period /1 *AF' &Z to A..I7.JAVo G35 , and state that to the best of my knowtedge and belef, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither lhe Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

, X>9 Commissions PA-2497 L.N & A Inspector's Signature National Board, State. Province, and Endorsements Date 3 34.vS S22o3 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 2 Fxen n Wa Kpnna" ninre PA 1i3AE Sheet 1 of Address
2. Pant Limerick Generalina Station Unit 2 Name P.O. Box 2300. Sanatoga PA 19464-2300 Work Order No. R0869137 Address Repair Organization P.O. No.. Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300 Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Nuclear Boiler (System 041) Line No. APE-2MS PSV-041-2F013J

%ILVee wase

- A rA r^_

5. (a) Applicable Construction Code ASME III 196L Edlion, Summer1970 Addenda alf %lobe (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19_89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yesor No)

MSRV PILOT TARGET 040 N/A

  • 114-03966 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 181 N/A PO# 10253 N/A REPLACEMENT YES ROCK ;W105 Traceability per Exelon Part Code Number.
7. Description of Work: Replaced main steam relief valve main body with reworked body No.181 and Dilot No.040
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure@

Other _ Pressure 1045 psi Test Temp. 16-o 'F.

NOTE: Supplemental sheets In form of ists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 In., (2) inforna-tion in ierms 1 through 6 on this report is included on each sheet, and (31 each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I WIO No. R0869137 Sheet 2 of 2 FORM NIS-2 (BACK)

S. Remarks None.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this revlacement conforms to the rules of the ASME Code, Section Xl. repair or replacemern Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed. i.. - J.H. Kramer. Engineer Date June 3. _ 2003 neror Owvner's Designee, Tile CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT Of Hartford. CT -have inspected the components described in this Owner's Report during the period 'Ii ,;,p C2 to /2 1.'e: 03 , and state that to the best of my knovledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 7 _,

Date /7 V l*h'Zeo 3 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name

'Yinrl&n Wsv KenneH. Rma PA I 934F Sheet 1 of 2 Address

2. Plant Limerick Generating Station Unit A Narme P.O. Box 2300. Sanatoca PA 19464-2300 Work Order No. R0869129 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoa. PA 194642300 Expiration Date N/A Address
4. Identification of System Nuclear Boiler (System 041) Line No. APE-2MS PSV-041-2F013K
5. (a) Applicable Construction Code ASME III 1968 _Edition, Summer1970 Addenda_ N/A .Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 59.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or

_________ ~~~~No)

MSRV PILOT TARGET 020 NIA 114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 148 N/A ¶114-18879 NA RELCM T YS ROCK PO 180253 N/A REPLAC Y Traceability per Exelon Part Code Number.

7. Description of Work: Replaced main steam relief valve main body vith reworked body No.148 and pilot No.020
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure i Other _ Pressure 1045 si Test Temp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 hI.x 11 in., (2) informa-tion in items 1 through E on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded t the top of this form.

(12/82) This Form (E00030) may be obtained Irom the Order Dept., ASME, 345 E.47th St., NewYork, N.Y. 10017

I I WIO No. R0869129 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks None.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this revlacement conforms to the rules of the ASME Code. Section Xl. repaW or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ;i J.H. Kramer Enineer Date June 3. , 2003 (ner or Owner s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvia and employed by HSBCT of Hartford. CT have inspected the components described in this Owner's Report during the period , -)2 to k:I 7t2)AJ7 63 ,and state that to the best of my knovedge and belief, the Owner his performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. A'

______________________________________Commissions PA-2497 L.N 8 A Inspector's Signature National Board, State, Province, and Endorsements Date t. 1 Jt / y (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner lUI bW -IOtLi,I  %'. LL%, Date June 3 2003 Name 200 Exelon Way. Kennett SQuare. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Slation Unh 2 Name P.O. Box 2300 Sanatoga. PA 19464-2300 Work Order No. R0869135 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 194642300 Expiration Date N/A Address
4. Ientification of System Nuclear Boier (Svstem 041) Line No. APE-2MS PSV-041-2F013L
5. (a) Applicable Construction Code ASME III 1968 Ed-ion Summe Dr 1_nr I l:UI v A44-12 i_%

Lit vrfl -

%,WC r.^^

t.UCe (b) Applicable Edition of Section Xl Utilized br Repairs or Replacements 19_§89

6. Identification of Components Repaired or Replaced end Replacement Components Repaired, ASME Code Name of Name of Manufacturer Serial National Other Year Replaced, or Stamped Component Manufacturer No. Board Identification Buit Replacement (Yes or No. No)

MSRV Target Rock

  • 11403966 Pilot Assembly 025 N/A PO# 180253 N/A Replacement Yes MSRV Body Target Rock *114-03966 151 N/A *O0 18023 N/A Replacement Yes (2) 1-318- MSRV Cardinal Heat# 8869139
  • 11493783 inlet flange studs Industrial Trace code D9' N/A PO# LS628644 N/A Replacement No (4)1-318" MSRV Alied Nut B Heat# 02293A
  • 114-93784 inlet flange nuts Bolt Trace code 216 N/A # LS669338 N/A Replacemert No (14) 1 MSRV NOVA Heat# 13853 Trace# N/A PO#1B0864- N/A Replacement No outlet flange studs Machine C574 8 C575 348270 (21)1 MSRV NOVA Heat# 12750
  • 11 476528 N/A outlet flange nuts Machine Trace# C663 N/A PO#180864- Replacement No 348308 I raceability per Exelon Part Code Number.

-_A- 0>-1 --- I -l ttD- .-C-8 - -;of I---s Lm2 C. 4 --D A -.1-l -AAtr -,

7. Description of VviJIF. flruet10 r,,,f dcciii ilc, VGiVC line,,. .LP..UVWFMi iCVVUiFlCIJ A

UUUV fVLu. i~jI CiRaJ LJiiUt 'U.VZ

8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure @

Other _ Pressure 05_ psi Test Temp. 168 OF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0869135 Sheet 2 of 2 FORM NIS-2 BACK)

Dm<ole 15 Ilnno V.

Applicable Manufacturefs Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reptacemert conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiratio Date NA Signed 9 J.H.KramerEngineer Date June 3. , 2003 twner owvner's Designee, Titl CERTIFICATE OF INSERVICE INSPECTION i, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ot Pennsvvanb and employed by HSBCT of HaM. CT -- have inspected the components described in this Owners Report during the period to_ _ 0 , and state that to the best of my knowledge and beret, the Owner has perfofmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME code, Section XL By signing this certificate nelher the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ommissions . PA-2497 I.N S A Inspector's Signature / National Board, State, Province, and Endorsements (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 2Qn Exelnn Wav Knnett Snare. PA 193I4E Sheet i of 2 Address
2. Plant Limerick Generatinc Station Unit 2 Name P.O. Box 2300. Sanatoa. PA 19464-2300 Work Order No. R0864454 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Cc)de Symbol Stamp N/A Name Authori22ation No. N/A P.O. Box 2300. Sanatoa PA 194642300 Expiraticin Date N/A Address
4. identification of System Nuclear Boiler (SEstem 041) Line No . APE-2MS PSV-041-2F013M 1n a A94n-As ^- -- _
5. (a) Applicable Construction Code ASME ll 196l Edition. Summer rol Miuviwsena.

KIa N`ll^ voae %112be (b) Applicable Edition of Section Xl Utilized for Repairs or Reptacements 19_QE9

6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)

MSRV PILOT TARGET 023 N/A

  • 114-18879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 1802S3 MSRV BODY TARGET 189 N/A 114-18879 NIA REPLACEMENT YES ROCK PO# 180253 NA RELCM T YS Traceability per Exelon Part Code Number.
7. Description of Work- Replaced main steam relief valve main body with reworked body No.189 and pilot No.023
8. ests conducted: Hydrostatic Pneumatk Nominal Operating Pressure 0 Other_ Pressure 14i5__psi Test emp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 12 h. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME. 345 E.47th St., New York, N.Y. 10017

I I WiO No. R0864454 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks None.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reglacement conforms to the rules of the ASME Code, Section Xi. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J.H. Kramer Encineer Date June 3. ,2003 Zpwner or Owner's Designee, Ttle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and empbyed by HSBCT of Hartford. CT have inspected the components described in this Owners Report during the period A} ' 2 to 1 ? )A)8J 50 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with th requirements of the ASME code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecti Commissions PA-2497 IN &A Inspector's Signature National Board, State, Province, and Endorsements Date /3 .S-*J* $Z (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Nare 2O EFeInn Wa1v Kenne .. ff or DA1CqAI Sheet I of 2 Address
2. Plant Limerick Generating Station UnH _

Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0864209 Address Repair Organization P.O. No., Job No. etc.

3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Nuclear Boiler (Svstem 041) Line No. APE-2MS PSV-041-2F013N
5. (a) Applicable Construction Code ASME III 1 9...Edtion. Summer 1970 Addenda N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19&89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~)~ ~~No MSRV PILOT TARGET 024 N/A *114-03966 N/A REPLACEMENT YES ASSEMBLY ROCK PON 180253 MSRV BODY TARGET 147 N/A

  • 114-03966 N/A REPLACEMENT YES ROCK ~~~~~~P180253 MAIN DISC TARGET 4719 N/A O114760253 2003 REPLACEMENT YES R__O__C_K___ _ __ _ _ __ _ _ _ _ _1 _ _ _80_2_53__

PO#__ ___ _ __ _ __ _ _

Traceability per Exelon Part Code Number.

7. Description of Work: Replaced main steam relief valve main body vith reworked body No.147 and pilot No.024
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure0 Other _ Pressure 1.j04 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of rtsts, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82) This Form (E0030) may be obtained rom the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

I WIO No. R0864209 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturers Data ReDorts are traceable by Exelon Work Order oackaoe.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol StamP NA Certificate of Authorization No. NA Expiration Date NA Signed . L. J.H.Kramengr ~. Date June 3. , 2003

(>wner or Owner's Designee, Tile CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT Of Hartford, C7 have nspected the components described in this Ovner's Report during the period 1 SAEP 02 to JkA/J ' 3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron or connected with this inspection.

_____________________________________Commissions PA-2497 .N S A Inspectors Signature National Board, State, Province, and Endorsements Date Z3- -A (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Genaration Co. LLC Date June 3. 2003 Name 200 Exelon Way. Kennett Square. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit Name P.O. Box 2300. Sanatooa PA 194642300 Work Order No. R0869130 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatooa, PA 194642300 Expiration Date NIA Address
4. Identification of System Nuclear Boiler (System 041; Line No. APE-2MS PSV.041-2F013S
5. (a) Applicable Construction Code ASME Itt 1968 Edition, Summer 1970 Addenda, . N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer Serial National Other Year Built Replaced, or Code Component Manufacturer No. Board Identification Replacement Stamped No. (Yes or No)

MSRV PILOT TARGET 030 N/A

  • 11418879 N/A REPLACEMENT YES ASSEMBLY ROCK PO# 180253 MSRV BODY TARGET 169 N/A *11418879 N/A REPLACEMENT YES ROCK POW 180253 (1) 1-1/8" HEAT No. 13350 NA TARGET SPLINE U.S. BOLT Trace No. 1WE ROCK PART N/A REPLACEMENT NO BOLT No. 204542-2 (1) 1118- ENERGY HEAT No. 2-3471LC N/A TARGET SPLINE STEEL LOT No. CEYS ROCK PART N/A REPLACEMENT NO NUT No. 204843-1 Traceability per Exelon Part Code Number.
7. Description of Work- Replaced main steam relief valve main body with reworked body No.169 and dilot No.030
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other _ Pressure j45_psi Test Temp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches. Gi drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

I I- .

W/O No. R0869130 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks None Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certity lhat the statements made in the report are correct and this redlacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Cerlificate of Authorization No. NA Expiration Date NA Signed (L. I.. _ J.H Kramer Eninee Date June 3, .2003 Uner or Ow/ner s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford CT have inspected the components described in this Owners Report during the period j'I 07 to I> JfAJJJ: 40w ,andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance vith the requirements of the ASME code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shafl be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

5K Commissions PA-2497 LN & A inspecto(s Signature /I National Board, State, Province, and Endorsements Date i, '

(12J82)

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Energy Cornpany Date JULY 20.2001 Name 200 Exelon Way, Kennett Square, PA 19346 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. C0193967 Address Repair Organizaton P.O. No.. Job No. etc,
3. Work Performed by Exelon Enermy Company Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date N/A Addess
4. Identification of System Fuel Pool Cooling Water System 043) Line No. GBB-210-1
5. (a) Applicable Construction Code ASME III 1974 Edition. Winter 1974 Addenda, N-416-1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Conponents Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamsped (Yes or

___________ ~~~~~~~~No) 3 N/A 114-92679 N/A REPLACEMENT NO

/ HALF RADNOR HEAT #

COUPLING ALLOYS 157VNR PO# 696958 Traceability per Exelon stock code number.

7.Descriptionotwork: ADDED VENT TO 2A RHR LINE (GBB-210)

8. Tests conducted: Hydrostatic t Pneumatic ! Nominal Operating Pressure Other t_ Pressure 22.5 psi Test Temp. 82 -F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) inforna-tion in items 1 through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(1Z182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ I W/O No. COI 82037 Sheet 2 of 2 FORM NIS.2 (BACK)

9. Remarks Manutactures Data Reports are Traceable by EXELON Work Order Packane Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement coniorns to the rules of the ASME Code, Section Xl. (repair or repLacement)

Type Code Symbol Stamp NA Certificate of rization No. NA Expirabon Date N/A Signe . Thomas W. Zeigler Date JULY 20. , 2001 Owner or Owners s Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvivania and employed by H.S.B.1.8 1.Company of Hartford, CT have inspected the components described in this Owners Report during the period 12 I4 P n tto 2. . LY O I , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspcon

________________________________ Commissions PA-2497 .N & A Inspedoes Signature National Board, State. Province, and Endorsements Date 2;3 7IVLY 2001 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Fr,aIn fnr*Ln tnmnanu I I r Date Mav 6. 2003

1. Owner _ czcPlull Drxltrwaxwil kulilnv. LLb Name 200 Exelon Wav. Kennett Scuare. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unhi Name P.O. Box 2300. Sanatga. PA 19464-2300 Work Order No. C0204536 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. NIA P.O. Box 230. Sanatoga PA 194642300 Expiration Date N/A Address
4. Identification of System Reactor Water Clean-uc (System 0441 Line No. DBB-105 Valve HV-044-2F039
5. (a) Applicable Construction Code ASME IIl 197L_Edition. Winter 1972 Addenda, 1516-2. 1567- 122.1682 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89.
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

____________________ ~~~~~~~~~~~~~~

4 Valve HV-

  • 11498630 044-2FM39 Borg- E-073A-1-2 N/A PO# 257805- 1998 Replacement Yes Warner 348190
  • Traceability per Exelon stock code number.
7. Description of work: Replaced 4 flanoed check valve.
8. Tests conducted: HYdrostatic Pneumatic Nominal Operating Pressue  :

Other 0 104Q5 psi Test Temp. N/A *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size 8 112 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York. N.Y. 10017

I .

W/O No. C0204536 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturer's data reports are traceable by Exelon work order package.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the reporl are correct and this replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 4 1 i J.H Kramer eng:neerl Date May 6. ,2003 O&*er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford CT have inspected the components described in this Owner's Report during the period .14? 0? _2to 9 A-lAy __ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

>~ /sg w < = 7mmissions- PA-2497 L.N &A Inspecor's Signature National Board, State, Province, and Endorsements Date 9 A>' W5 :

(12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Generation Co.. .LLC Date MAR. 08. 2003 Name 300 Exelon Way. Kennet Suare, PA. 19348 Sheet 1 Of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatooa. PA 19464-2300 Work Order No. R0867313 Address Repair Organ'eation P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorizaion No. N/A P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-06-35
5. (a) Applicable Construction Code ASME ll 19 68 Edition. 69 Addenda, 1361-1 Code Case (b) Applicable Editon of Section Xi Utilized tor Repairs or Replacements 19__9
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufactuer Nabonal Other Year Built Replaced. or Code Component Manufacturer Serial No. Board No. Idenification Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~N o)

CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES ROD ELECTRIC 5178 DRIVE

7. Descuiption of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic_ Nominal Operating Pressure X Other Pressure __J045 si Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1t2 in. x 11 in., (2) informa-tion in items I through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I -J -

WIO No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed - C -E5 e i) f ) Date / l Owner or Owner's Daignee, Tle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvivania and employed by H.S.B.I.S 1.Comoanv of Hanford. CT - have inspected the components descibed in this Owner's Report dunng the period 2c. sr 0i to e APR 63 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ownees Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal irury or property damage or a loss of any kind arising trom or connected with this inspection.

  • A f^ Xt<?z,< F 7 Commissions PA-2497 I.N & A Inspector's Signature National Board, State, Province, and Endorsements Date /4 Ai4z' i' s (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 08, 2003 Name 300 Exelon Way, Kennett Suare. PA. 19346 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date _ _ .NA Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-5299-14-43
5. (a) Applicable Construction Code ASME III 19 68 Edition, w' 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xi Utlized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ __ _ _ _ _ __ _ _ _ _ _ _ _ _ _ ~~~)~~~No CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES RODELCRC4 DRIVEEL C R C93

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic__ Nominal Operating Pressure X Other Pressure 1045 psi Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York. N.Y. 10017

WIO No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the nles of the ASME Code, Section Xl. repair or replacement Type Code Symbol StamP NA Certificate of Authorization No. NA Expiration Date NA Signed _ - D (j- ir . -UC) Date ,.:/'

20 C'- 3 Owner or owner's Dsignee Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsIvania and employed by H.S.B.I.& I. Company Of Hartford. CT . .have inspected the components described in this Owners Report dunng the period e2 O'- to AM AP 0 :. , and state that to the besl of my knowledge and belief, the Owner has pedormed examinaions and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xi.

By signing this cerlificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

G g 7 '-fir+ 4 Commissions PA-2497 LN & A inspectors Signature National Board. State, Province, and Endorsements Date 4A A 3 (12f82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 08,2003 Name 300 Exelon Way, Kennet Square. PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanaloa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No.. Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga,PA 1946-2300 Expiration Date N/A Addrcss
4. Identification of System 047 CONTROL ROD DRIVE Lhe No. 20-S299-18-35
5. (a) Applicable Construction Code ASME III 19 68 Edition, w 69 Addenda, 1361- 1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement ComponentE Repaired. ASME Name of Name of Manufacturer National Other Year Buit Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~~~ ~~~~~~No)

CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES ROD ELECTRIC 4948 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostabc Pneumabc _ Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 IF.

NOTE: Supplemental sheets in lorm of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 lhrough 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

WIO No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT coniorms to the rles of the ASME Code.Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /? Ss f (Zie I

\ Date V / . 20 t .3 Owner or Owner's O*signeeTitle

-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennstlvania and employed by H.S.B.I.& 1.Company of Hartford. CT have inspected the components described in this Ownees Report during the period '2i 5 C'3 to 14 APR ,.Mand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Reponl. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with his inspectior.

i n s , .fc~-2~~~ Commissions PA-2497 IN & A Inspetor's Signature National Board, State, Province, and Endorsements Date /4 A : iZ.CC (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Co.. LLC Date MAR. 09. 2003 Name 300 Exelon Way. Kennett Sauare PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0867313 Address Repair Organiation P.O. No., Job No. etc..
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. NJA P.O. Box 2300. Sanatoqa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-5299-22-11
5. (a) Applicable ConstruCtion Code ASME III 19 68 Edition, wf 69 Addenda, 1361- 1 Code Case (b) Applicable Edition of Section Xl Utlized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer Natonal Other Year Built Replaced. or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or CONTROL GENERAL N/A N/A 1975 REPLACEMENT YES DRODE ELECTRIC 7366
7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostabc Pneumatc _ Nominal Operating Pressure X Other I Pressure 1045 Psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-lion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

1 W/O No. R0867313 Sheet2of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENi conforms to the nes of the ASME Code, Section Xi repair or replacement Type Code Symbol Stamp NA Certificale ot Authorization No. NA Expiration Date NA Signed X t2 J f (iJe e; y /) Date AM' .,20 Q3 Owner or Owner's ne Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressue Vessel Inspectors and the State or Province of PennsVvania and employed by H.S.B.I.& I. Company of

-HarordCT have inspected the components described in this Owner's Report during the period  :: r' a .to Af z eo and state that to the best o1 my knovAedge and belief, the Owner has pedormed examinations and taken cornective measures descibed in this Owner's Report in accordance vith the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal iury or property damage or a loss of any kind arising from or connected with this inspection.

L3<mY 6cs - Commissions PA-2497 I.N 8 A Inspector's Signaturq' National Board, State, Province, and Endorsements Date.. /A8A? . ;Z 3 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Co.. .LLC Date MAR. 09. 2003 Name 300 Exelon Way. Kennett Square. PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoga. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatocga, PA 19464-2300 Expiration Date N/A Awress
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-22-15
5. (a) Applicable Construction Code ASME III 19 68 Edition, w 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manutfacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or CONTROL GENERAL N/A N/A 1974 REPLACEMENT YES D ELECTRIC 5743
7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of sts, sketches, or dravwings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the nules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certfflicate of Authorization No. NA Expiration Date NA Signed /& \_ 'p-f-lt t3 (.k zz4d) Date ' .20 g _

Owner or Owner's Desiee. Tit CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsYvania and employed by H.S.B.I.& 1. Company of Hartford. CT have inspected the components descnbed in this Owners Report durng the period ;Z6 z2 0. to f A iz?l in 3 - .and state that to Ihe best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Ownees Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranly, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither lhe Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising trom or connected with this inspection.

,4 ,X7Dc47com m s ions PA-2497 I.N & A lnspectoes Signature National Board, State, Province, and Endorsements Date ;JV APR WL2oC3C (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Co.. .LLC Date MAR. 08.2003 Name 300 Exelon Wav, Kennett Suare. PA. 19348 Sheet 1 o1 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Saratoqia. PA 19464-2300 Expiration Date _- N/A ___NA_

Address

4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-22-51
5. (a) Applicable Construction Code ASME III 19 68 Edition. v' 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ _ _ __ _ __ _ __ _ __ _ __ _ _ __ __ _ _ _ __ _ _ _ _ _ ~~ ~~~~No)

CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES ROD ELECTRIC 4843 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatc _ Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size 8 1/2 in. x 11 in.. (2) informa-tion in items 1 tIhrough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I ..

W/O No. R0867313 Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code. Section Xl. repair or replacemenl Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 6/it (9.0 (5(WES@)Date f Owneror O-2-ers Desi,Ti CERTIFICATE OF INSERVICE INSPECTION i, the undersigned. holding a valid commission issued by the National Board of Boiler and Piessure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.I.S 1.Comoanv Of Hartford. CT have inspected the components described in this Owner's Report during the period sZC dc7: C :3 to i* 4' eF . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this cerlificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner lor any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions PA-2497 I.N & A InspeCtor's Signature National Board, State, Province, and Endorsements Date A'A/J'R j (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Co.. .LLC Date MAR. 09. 2003 Name 300 Exelon Way, Kennett Suare, PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatooa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300 Sanatnoa. PA 19464-230G Expiration Date _ NIA Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-26-07
5. (a) Applicable Construction Code ASME III 19 68 Edition. w'69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identificalion of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manutacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~~~~~~~~~~~~N CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES DRIVE ELECTRIC 5179

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic _ Nominal Operating Pressure X Other Pressure 1045 psi Test lemp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in.. (2) informa-tion in items 1 through 6 on this report is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12J82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

WIO No. R0867313 Sheet 2 ot 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the nles of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed: _z 'A . 4 (L'62e i6s) Date - . 20 0 3 Owner or Owners Desighee Titjb CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Presstxe Vessel Inspectors and the State or Province ot Pennsvtania and employed Dy H.S.B.I.& I. Company of Hartford. CT have inspectec the components described in this Ower's Report during the period 7 C E to /4i .A-4P 'q _. and state that to the best of my knowledge and belief, the Owner has perormed examinalions and taken corrective measures described in this Owner's Report in accordance with the requirements ot the ASME Code,Section XI.

By signing thiS certificate neither the Inspector nor his employer makes any warranty, expressed or implied. conceming the examinations and corrective measures described in this Owner's Report. Fuilhermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising trom or connected with this inspection.

____ o m m is si _ on_____________

mss PA-2497 I.N 8 A Inspector's Signature National Board. State. Province, and Endorsementt Datete ;ZI C, (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 09.2003 Name 300 Exelon Way. Kennet Suare. PA. 1934E Sheet 1 of _

Address

2. Plant Limerick Generating Station UNil 2 Name P.O. Box 2300. Sanatoga. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. IN/A P.O. Box 2300. Snatoqa. PA 1464-2300 Expiration Date ____________________N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-30-59
5. (a) Applicable Construction Code ASME IlIl 19 68 Edition, wl 69 Addenda, 1361- 1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identificaton of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manutacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ _ __ _ __ _ _ _ __ __ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~)~~~No CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES ROD ELECTRIC 4939 DRIVE EETI

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure 1045 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) inforrna-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12t82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

WIO No. R0867315 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENr conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /2 Date .200 Owner or Owner's Design , Title/

CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.I.& 1.Compary Of Hartford. CT have inspected the components described in this Owner's Report during the period _Z 63 023 to i4 -APt CO , and state that to the best ol my knowledge and belief, the Owner has performed examinations and taken corrective measwes described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising trom or connected vith this inspection.

, r -  ; 7 Commissions PA-2497 I,N 8 A Inspe6or's Signature / National Board. State. Province, and Endorsements Date t4 A/?' 28zo<2-(12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Co.. .LLC Date MAR. 09.2003 Name 300 Exelon Way. Kennett Square, PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoca. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoaa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Une No. 20-S299-34-03
5. (a) Applicable Construction Code ASME III 19 68 Edition. w 69 Addenda, 1361- 1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identfication Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ) ~ ~ ~ ~~No

~~~~~

CONTROL GENERAL N/A N/A 1975 REPLACEMENT YES ROD ELECTRIC 5986

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure 1045 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certrfy that the statements made in the report are correct and this REPLACEMENT conforms o the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No_ NA Expiration Date NA Signed' Date '- i .20 a3 Owner or Owners Desig,ee. TitI6 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ot Pennslvania and employed by H.S.B.I.& 1.Company of Hartford. CT have inspected the components described in this Owner's Report during the period 2 i A75 7 C73 to i4l -4P? 023 .and state that 1o the best of my knowledge and belief, the Owner has performed examinations and taken corTective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shalt be liable in any manner for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection.

inpcin ;iCommissions PA-2497 I.N & A Inspector's Signature National Board, State, Province, and Endorsements Date /4 ARR I2cdC (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 09. 2003 Name 300 Exelon Way, Kennett Square. PA. 19348 Sheet 1 of Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No.. Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp NIA Name Authorization No. N/A P.O. Box 2300. Sanatoqa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIvE Line No. 20-S299-34-07
5. (a) Applicable Construction Code ASME III 19 68 Edition, v 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Buit Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or CONTROL GENERAL N/A N/A 1974 REPLACEMENT YES ROD ELECTRIC 5971 DRIVE
7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 *F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in.. (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept.. ASME, 345 E.47th St, New York, N.Y. 10017

-~~ ~ ~~~

I WIO No. R0867313 Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate o Authorization No. NA Expiration Date NA Signed J'. 4-st / 6S7cv5't8A")1 ate - ,20 3 Owner or Owners Designed, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel lnspectors and the State or Province of Pennsylvania and employed by H.S.B.I.& 1.Companv of Hartford. CT have inspected the components described in this Owners Report during the period 7 =d,=E73 03 to i4 e -_ -a ,andstate that to the best of my kriowledge and belief, the Owner has pedormed examinations and taken corective measures described in this Owners Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissionf PA-2497 I,N & A Inspector'S gnature National Board, State. Province, and Endorsements Date A jt-Z4Y73 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Ownetr. Exelon Generation Co.. .LLC Date MAR. 09.2003 Name 300 Exelon Way. Kennett Sauare. PA. 1934E Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300, Sanatoqa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300, Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-34-11
5. (a) Applicable Construction Code ASME III 19 68 Edition. W 69 Addenda. 1361- 1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ __ __ __ _ _ _ _ _ _ __ __ _ __ _ _ _ __ _ _ _ ~~No)

CONTROL GENERAL N/A N/A 1974 REPLACEMENT YES ROD ELECTRIC 5266 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other , Pressure 1045 psi TesOTemp. 168 F.

NOTE: Supplemental sheets in form of lists, sketches. or dravings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W1O No. R0867313 Sheet 2 ot 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT contorms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate ot Authorization No. NA Expiration Date NA Signed i "I - l I I) Date A / ,20 Z' 3 Owner or Owners DesigneA Title/

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.I.& 1.Company of Hartford. CT have inspected the components described in this Owner's Repon during the period 26 'k5 C3 to j4 ; c3 and state that to the best of my knowledge and belief, the Owner has pedorrned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Secbon Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concemring the examinations and crrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

z<'%,. <@.W+?c ommission! PA-2497 L.N 8 A Inspector's Signature National Board, State. Province, and Endorsements Date ,4AI' ,8Z6 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Generation Co.. .LLC Date MAR. 09. 2003 Name 300 Exelon Way, Kennett Square. PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No.. Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A

.O Box 2300. Sanatoqa. PA 19464-2300 Expiration Date N/A Adoress

4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-38-23
5. (a) Applicable Construction Code ASME III 19 68 Edition, wI69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manutactwer National Other Year Buit Replaced, or Code Component ManufacuLrer Serial No. Board No. Identification Replacement Stamped (Yes or CONTROL GENERAL N/A N/A 1975 IEPLACEMENT YES ROD ELECTRIC 6613 DRIVE
7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic _ Pneumabc _ Nominal Operating Pressure X Other Pressure 1045 psi Test Temp. 168 OF.

NOTE: Supplemental sheets i form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained trom the Order Dept.. ASME, 345 E.47th St.. New York, N.Y. 10017

WIO No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT confromms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NA CeTificate of Authorization No. NA Expiration Date NA Signed /? 'vr/

Owner or Owners Desig , Tit

  • ) es46 )Date V'4 / 20 6 3 CER7IFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board ot Boiler and Pressure Vessel Inspectors and the State or Province ot Pennsylvania and employed by H.S.B.I.& I. Company of Hartford. CT have inspected the components described in this Owners Report during the period ,2 ,c JR t'3 to it AEGR t . and state that to the best of my knowledge and belief, the Owner has perlormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss o1 any kind arising rom or connected with this inspection.

_______________________________________Commission! PA-2497 LN 8A Inspector's Signature $ National Board, State, Province, and Endorsemente Date t 4'A - ?3 (12.02)

2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. ,LLC Date MAR. 09 2003 Name 300 Exelon Way. Kennett Suare. PA. 19348 Sheet 1 of Address Limerick Generatina Station Unit 2
2. Plant Name P.O. Box 2300. Sanatoa, PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. ec.
3. Work Pertormed by Exelon Type Code Symbol Stamp N/A a

Name Authorization No. N/A P.0. Bnx 2300. Sartnca. PA 19464-2300 Expiration Date NIA Address

4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-38-59
5. (a) Applicable Construction Code ASME III 19 74 Edition, NONE Addenda. 1361-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _N o)

CONTROL GENERAL N/A NtA 1974 REPLACEMEM YES ROD ELECTRIC 6506 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1046 psi Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this reporl is included on each sheet, and (3) each sheet is numbered and te number of sheets js recorded at the top of this form.

(12/82) This Form (E00030) may be obtained Irom the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT contorms to the rules of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed / - -" - CY ffi' Date v ,20 . 3 Owner or Ownes Dem4hee, Titx CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pensylvania and employed by H.S.B..& 1.Company of Hartford. CT have inspected the components described in this Owners Report during the period 2 .  ; C! to a4 YZ C  % ,and state that to the best of my knowledge and belief, the Owner has pelormed examinations and taken corrective measures described in this Ownef s Reporl in accordance with the requiements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owneres Report. Furthermore. neither the Inspector nor his employer shat be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______________________________________ o mmissionf PA-2497 I.N &A Inspectors Signature National Board, State. Province. and Endorsements Date /4 APP h2cc3 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exeion Generation Co.. .LLC Date MAR. 09.2003 Name 300 Exelon Wav. Kennet Suare. PA. 1934E Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanaloa, PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatooa, PA 19464-2300 Expiralion Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-42-19
5. (a) Applicable Construction Code ASME III 19 68 Edition, W'69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name ol Name ot Mamutacturer National Other Year Buit Replaced, or Code Component Manufacturer Serial No. Board No. Identificabon Replacement Stamped (Yes or

_ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ ~~~~~~~~~~~~~~

CONTROL GENERAL NIA N/A 1973 REPLACEMENT YES ROD ELECTRIC 4784 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 OF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form E00030) may be obtained from the Order Dept., ASME, 345 E.47th St, New York, N.Y. 10017

ffi-W/O No. RO867312 Sheet 2 o 2 FORM NIS.2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certHy that the statements made in the report are correct and this REPLACEMENT conforms lo the rles of the ASME Code, Section Xi repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed / J _ Date / ,

Owner or Owners Detignee, 1tle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennslvania and employed by H.S.B.I.& 1. Company ot Harford CT t have inspected the components described in thisOner'sRepondunngthe period Z -7Y 3 to f4 AA ( 3 - and state that to the best of my knowledge and belief. the Owner has perlormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss o any kind arising rom or connected with this inspection.

vX<,3Z - , X= . 2 - CommissionF PA-2497 I.N 8 A Inspector's Signature National Board, State. Province, and Endorsements Date (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Fwalnn- 9"DrtinI I - Date MAR. 09. 2003

1. Owner 1- Na .. .

Name 300 Exelon Way, Kennett

  • SQuare. PA. 1934E Sheet t of 2 Address
2. Plant Limerick Generating Station Unit -

Name P.O. Box 2300. Sanatoqa PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No.. Job No. etc.

3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatooa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-42-51
5. (a) Applicable Construction Code ASME III 19 6E Edition, W 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name o1 Manufacturer National Other Year Built Replaced. or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or CONTROL GENERAL N/A N/A 1974 REPLACEMENT YES ROD ELECTRIC 6363 DRIVE
7. Description of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic _ Pneumatic_ Nominal Operating Pressure X Other Pressure 1045 psi Test Temp. 168 OF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) infomta-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

W/O No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certity that the statements made in the report are correct and this REPLACEMEN'T contorms to the rules ot the ASME Code.Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed _ 4 ;i slo-l Jate / 20 0 3 Owner or Owners Designa. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.I.& I. Companv of Hartford, CT -have inspected the components desribed in this Owner s Report during the period Z; r , O.:

C7 to )4- AJP2 a s , and state thal to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

i 2v 7>-.N-- Commission<

.vF - PA-2497 IN & A Inspectors Signature National Board, State. Province, and Endorsements Dale &4 Aa-, a,, 2ac5 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. LLC Date MAR. 09.2003 Name 300 Exelon Way. Kennetl Suare. PA. 19348 Sheet 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc..
3. Work Periormed by Exelon Type Code Symbol Stamp N/A Name Authorization No. NA P.O. Box 2300. Sanatoca. PA 19464-2300 Expiration Date N/A Addrec:
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S29946-27
5. (a) Applicable Construction Code ASME Ill 19 68 Edition, W'69 Addenda, 1361.1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Repbcements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ __ _ _ _ _ __ _ _ _ _ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~)~ ~ ~ ~~No CONTROL GENERAL N/A N/A 1974 REPLACEMENT YES ROD ELECTRIC 6264 DRIVE

7. Description of Work REPLACED ONE CONTROL ROD DRIVE B. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 OF.

NOTE: Supplemental sheets in torm of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017i

WIO No. R0867313 Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that he salements made in the report are correct and this REPLACEMENT contorms to the rules of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date _ NA Signed -e e tovs e )Date Y 1' -.20 6 3 Oyner or Owner's Desi ,tTitL CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.I.S I. ComDanv of Hartiord. CT have inspected the components described in this Owners Report during the period 2 -1/ c 3 to 1 4 02 c3 . and state that to the best of my knowled9e and belief. the Owner has performed examinations and taken corrective measures described in this Ownees Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures desaibed in this Owner's Report. Furthermore, neither the Inspeclor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising trom or connected with this inspection.

_____ m m i s s i on___________________

_ msn PA-2497 I.N A Inspeclor's Signature National Board, State. Province, and Endorsements Date .J AS 2<rC3 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions o1 the ASME Code Secbon Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 09.2003 Name 300 Exelon Wav. Kennett Souare. PA. 19346 Sheet 1 of Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No.. Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorizaton No. N/A P.O. Box 2300, Sanatoaa. PA 19464-2300 Expiration Date N/A Address
4. Identificabon of System 047 CONTROL ROD DRIVE Line No. 20-S299-46-51
5. (a) Appricable Construction Code ASME III 19 68 Edition, W 69 Addenda, 1361-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. dentificabon of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identfilcation Repacement Stamped (Yes or

_ _ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~No

)

CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES DROIVDE ELECTRIC 5207

7. Descuiption of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operaing Pressure X Other I Pressure 1045 psi Test Temp. 168 IF.

NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) inforna-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form E00030) may be obtained from the Order Dept.. ASME, 345 E.47th St., New York, N.Y. 10017

WlO No. R086731-Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATACHED CERTIFICATE OF COMPLIANCE We certity that the statements made in the repron are correct and this REPLACEMENi conforms to the rules of the ASME Code. Section Xl. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed_ e o w iie )enga. iI;Date "/- f .20 C' -5 Owner or Owgner's *esign ,.Title CERTIFICATE OF INSERVICE INSPECTION I, the undersioned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ot Pennsylvania and employed by H.S.B.I.& . Company ot Har_tord_ CT _have inspected the components descibed in this Owner's Reporl during the period .Z? . fi5 t25 to j/ APR C3, , and state that to the best of my knowledge and belief. the Owner has perlormed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of Ihe ASME Code. Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecton.

.'.g..-?

X 4!.-e 1 9Cor missions PA-2497 I.N & A Inspector's Signature / National Board. State. Province, and Endorsements Date A2 APfg; <2J3 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co., .LLC Date MAR. 09.2003 Name 300 Exelon Wav, Kennett Square. PA. 1934£ Sheet 1 oi 2 Address
2. Plant Limerick Generatina Station Unit Name P.O. Box 2300. Sanatoca. PA 19464-2300 Work Order No. R0867313 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp NIA Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Dale N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-50-47
5. (a) Applicable Construction Code ASME III 19 6 Edition, W '69 Addenda, 1361- 1 Code Case (b) Applicable Edition of Section Xl UUlized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ __ _ _ _ _ __ _ ~~~~~~~~~~~No)

CONTROL GENERAL NIA N/A 1973 REPLACEMENT YES ROD ELECTRIC 4991 DRIVE

7. Description oi Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test lemp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion in items 1 through 6 on this repon is induded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this torm.

(12182) This Form E00030) may be obtained from the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

WIO No. R0867313 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /?7 '.e W Date Al - / .20 3 Owner or Owner's signee.ite CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a valid commission issued by the National Board of Boiler anrd Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H.S.B.l.& I. CompanY of HarMtord. CT have inspected the components described inthis Owner's Report during the period 0 3 to /4 AFR Q5 - and state that to the best of my knowedge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Reporl in accordance with the requirements of the ASME Code. Section %1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected vith this inspection.

_____________________________________Commissions PA-2497 L.N S A Inspector's Signature / National Board, State. Province, and Endorsements Date 2

/APf SO14~ ZZ (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Co.. .LLC Date MAR. 09. 2003 Name 300 Exelon Way. Kennett Sauare. PA. 1934E Sheel 1 of 2 Address
2. Plant Limerick Generatina Station Unit 2 Name P.O. Box 2300. Sanatoqa. PA 19464-2300 Work Order No. R0867313 Address Repair Organizabon P.O. No., Job No. etc.
3. Work Performed by Exelon Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanaloqa. PA 19464-2300 Expiration Date __ __ __N/A Address
4. Identification of System 047 CONTROL ROD DRIVE Line No. 20-S299-58-35
5. (a) Applicable Construction Code ASME III __9 68 Edition. W 69 Addenda. 1361-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. ldentification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ __ __ __ _ _ __ _ _ _ _ __ _ _ _ _ _ _ _ _ _ ~~~~~~~~~~~~No CONTROL GENERAL N/A N/A 1973 REPLACEMENT YES ROD ELECTRIC 4973 DRIVE

7. Descripbon of Work REPLACED ONE CONTROL ROD DRIVE
8. Tests conducted: Hydrostatic _ Pneumatic Nominal Operating Pressure X Other I Pressure 1045 psi Test Temp. 168 IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0867313 Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks MANUFACTURER DATA REPORT ATTACHED CERTIFICATE OF COMPLIANCE We certify thal the statements made in the report are correct and this REPLACEMENT contorrns to the nules of the ASME Code,Section XI. tepair or replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /e Date S .20 0 Si Owner or Owner's Dedignee. 7itle CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsY!vania and employed by H.S.B.I.& 1.Company of Harford, CT have inspected the components described in this Owners Report during the period A'B 4,5C e.-3 to iJ4 4C 5, . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificale neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner or any personal injury or property damage or a loss of any kind arising irom or connected with this inspection.

"6- 7%* CommissionF PA-2497 I.N & A Inspector's Signalure / National Board. State, Province, and Endorsements Date ,4 1,4,qie <:*l223 (12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Generation Companv. LLC Date Mav 6 2003 Name Sheet 1 of 200 Exelon Way, Kennett Square, PA 19348 Address
2. Plant I imprick Gpnpratinn Station Unit Name P.O Box 23 Sanatooa PA 19464-23W Wotk order # R0891 800 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A PO. Box 23.00 Snatona. PA 46A-300 Fxniralinn Date NIA Address
4. Identification of System StandByLjguiContrc err-04S LineNo ECB-214 VatveXV-048-2F004C
5. (a) Applicable Construction Code ASME III 1977_Edition. Summer 1977 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_§89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped INLET IST CONAX 6150 N/A 114-77023 2001 REPLACEMENT NO FITTING PO# 184737 TRIGGER IST CONAX 6152 N/A *114-77023 2001 REPLACEMENT NO BODY PC_184737 1raceability per Exelon part code number.
7. Description of Work Replaced exolos ve valve inlet fitting and trigger body
8. Tests conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a Other _ Pressure 1220 psi Test lemp. NIA F.

NOTE: Supplemental sheets in form of lists, sketches, or dravings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in iems through 6 on this repott is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this lorm.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

Work Order# R0891 800 Sheet 2 of 2 FORM NIS-2 BACK)

9. Remarks: Manufacturer's data reports are traceable by Exelon work order vackaoe.

Applicable Manufacturer's Data Reports to be attachecs CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reolacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp NA Certificate of AuthorizatiOn No. NA Expiration Date NA Signed C) 9 & 44 J.H. Kramer engineer Owner or Owner's Designee, Title Date May6_ 2008 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province o Pennsvlvania and employed by HSBCT o Hartford, CT -have inspected the components described in this Owner's Report during the period _ il . 63 to 9 A4AY g2 - and state that to the est of my knowledge and belief, the Owner has performed examinations and taken corective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed ot implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury o property damage or a loss of any kind arising trom or connected with this inspection.

___ Commissions PA-2497 I.N &A Inspector's Signature National Board. State, Province, and Endorsements Date -)(AY 20 5.

(12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Company. LLC Date May 13. 2003 Name 200 Exelon Way Kenneft Square. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unft 2 Name P.O Box 2300. Sanatoga PA 19464-2300 Work Order No. COI 94970 Address Repair Organization P.O. No.. Job No. etc..
3. Work Performed by Exelon NucleaT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Senetog, PA 19464-230Q Expiration Date NlA.

Address

4. Identification of System Residual heat removal (System 051) Line No. GBB-217 GBC-204 2B-E205
5. (a) Applicable Construction Code ASME IlIl 19_§ Ediion, N/A Addenda. N/A Code Case (b) Applicable Edtion of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No)

(2) Heat Carpenter

  • 114-36635 Exchanger Exelon Heat# 721938 N/A PO# 180864- NIA Replacement No tube plugs 348902 (64) -118- Nova Heat codes 116-12072 Replacement No water box Machine C156, E868 8 N/A PO# 180864 N/A studs TMJ raceability per Exelon stock code number.
7. Description of work: Plugged and seat welded one RHR heat exchanger U-tube. Replaced heat exchanger water box flange studs.
8. Tests conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure, :

Other D 831 psi Test Temp. N/A 'F.

NOTE: Supplemental sheets in form of lists, sketches, or dravwings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered-and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. COI 94970 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Tube plugs installed in accordance with Exelon ECR LG-03-00156 Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the eport are correct and this replacement conlorms to the rules of the ASME Code, Section Xl. (repair or replacement) lype Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed i>) 4 _ J.H. Kramer lennineer Date Ma 13. . 2003 ner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Slate or Province of Pennsvtvania and empyed by HSBCT Of Harnford. CT have inspected the components described in this owners Reporl during the period bQ MAR 02i to J2 . jrv( and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in anfner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -

Co sissiore PA-2497 I.N & A Inspectors Signature National Board. State, Province, and Endorsements Date /2 XJW3' (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Companv. LLC Date May 1. 2003 Name 200 Exelon Way, Kennett Sauare. PA 19348 Sheet 1 of Address
2. Plant Limerick Generating Station Unrt 2 Name P.O. Box 2300. Sanatooa, PA 19464-2300 Work Order No. C0203362 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exebon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300 Sar.atow. PA 14WA-2300 Expiration Date N/A Address
4. Identification of System Residual heat removal (System 051) Line No. DCA-204 Valve HV-051-2F050E
5. (a) Applicable Construction Code ASME III 1974 Edition. Summer 1974 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 es
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 12" Valve ' 114-02791 HV-061- Atwood Heat# 91499 NfA POl 189068 1999 REPLACEMENT YES 2F050B Disc Morrill SIN 1 a 257796-348062 I raceability per Exelon stock code number
7. Description of work: Valve disc replaced
8. Tests conducted: Hydrostatic C Pneumatic Nominal Operating Pressure o:

Other C 1045 psi Test Temp. 168 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. C0203362 Sheet 2 of 2 FORM NIS2 (BACK)

9. Remarks Manulacturer's data reports are traceable by Exelon work order packane.

Applicable Manufacturers Data Reports to be atlached CERTIFICATE OF COMPLIANCE We certily that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Ce w

  • J.H. Kramer tenaineer) Date May 5. 200 .
  • Fer or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province ot Pennsylvanb and employed by HSBCt Of Hatford. CT have inspected the components described in this Owners Report during the period , AJ C3 to S MAY 6 ,andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures desctibed in this Owners Reporl in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any m ner for any personal injury or property damage or a loss of any kind arising rom or connected vith this inspection.

,*Zz 6 L 7Z< C CommissonE PA-2497 I.N A Inspectors Signature National Board, State, Province, and Endorsements Date 9_2gS _2Ci 5

(12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generalion Companv. LLC Date May 1. 2003 Name 200 Exelon Way. Kennett Souare. PA 19348 Sheet 1 of Address
2. Plant Limerick Generating Station Unit Name P.O. Box 2300. Sanatoga. PA 19464-2300 Work Order No. C0204446 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatooa. PA 19464-2300 Expiration Date NIA Address
4. Identification of System Residual heat removal (System 051 ) Line No. DCA-204 Valve HV-051-2F050A
5. (a) Applicable Construction Code ASME I 19274 _Edition, Summer 1974 Addenda. NIA Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 12, Valve Atwood 8 1-50301-A NIA N/A 2001 REPAIR NO HV-051 - Morrill 2F050A
7. Description of work: Valve disc Post weld repaired
8. Tests conducted: Hydrostatic O Pneumatic Nominal Operating Pressure U:

Other 0 1045 psi Test Temp. 168_ 'F.

NOTE: Suppiemental s *eets in form of lists, sketches, or drawings may be used, provided (1) sze 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

I I WIO No. C0204446 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks None Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code, Section Xi. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed (geTte9 J.H. Kramer (engineer) Date Mav 1 , 2003 O@eror Owflets Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvia and employed by HSBCT -f Harttord. CT have inspected the components described in this Owners Report during the period j 7Wk C3 to 9 i1-AY G3 .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the recuirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any ma er for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

95%;t <{rz Commissions PA-2497 I N 8 A Inspectors Signature National Board, State, Province, and Endorsements Date 9 HA4Y la*Z lK*3 (1V82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Generation Company. LLC Date Mav 5. 2003 Name 200 Exelon Way, Kennett Square, PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit Name P.O. Box 2300. SanatoQa. PA 19464-2300 Work Order No. R0724582 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanaloqa PA 19464-2300 Expiration Date N/A Address
4. Identification of System Residual heat removal (System 051) Line No. GBB-219 Valve 051-2F0900
5. (a) Applicable Construction Code ASME li 19 71 Edition, Winter 1973 Addenda, N/A Code Case (b) Applicable Ediion of Section Xl Utili2ed for Repairs or Replacements 19 9
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year ButitH Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

___________ ___________ ~~~~~~~~~~~~~~

4- Valve

  • 114-33943 051-2F090D Velan 7365 N/A PO# 179323 2001 REPLACEMENT YES Disc
  • I raceability per Exelon stock code number
7. Description of work: Valve disc replaced
e. lests conducted: Hydrostatic D Pneumatic Nominal Operating Pressure .

Other D 162 psi Test 7emp. NIA_ 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) intorma-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82;, This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 1001

I - - lI I W/O No. R0724585 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks Manufacturer's daie eoorts are traceable by Exelon work order packaoe.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization Nc NA Expiration Date NA Signed JH. Kramer (engineer) Date May 5 , 2003 or Owner s Designee, Title ov CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsv!vani2 and employed by HSBCT of Hartford CT have inspected the components described in this Owners Report during the period /, Z{* l2 to 9 .4Y (; ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in an anner for any personal injury or property damage or a loss of any kind arising trom or connected with this inspt:jo:n*

CommissionE PA-2497 I.N &A Inspectorus Srna ure National Board, State, Province, and Endorsements Date AV in (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI r aoInnCntoinRnnn I r Date Mav 7. 2003

1. Owner Name 200 Fxelon Way Knnett Scuare PA 1934F Sheet 1 of I Address
2. Plant Limerick Generatinq Station Unt 21 Name P.O. Box 2300. Sanaloga. PA 19464-2300 Work Order No. R0863913 Address Repair Organization P.O. No., Job No. etc.,
3. Work Performed by Exelon Nuclear lype Code Symbol Stamp N/A Name Authorization No. N/A P.C. Box 2300, Snasa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Residual heal removal (System 051) Line No. GBB-219 Valve 051-2F090C
5. (a) Applicable Construction Code ASME Il t91L _ Edition, Winter 1973 Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Bult Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or

__________ __________ ~~~~~~~~~~~~~~~

4 Valve

  • 114-33943 051-2F090C Velan 7097 N/A POW 155137i 1996 REPLACEMENT YES Disc 1raceability per Exelon stock code number.
7. Description of work: Valve disc replaced.
8. Tests conducted: Hydrostatic C Pneumatic o Nominal Operating Pressure
  • Other C, 150 psi Test Temp. N/A *F.

NOTE: Supplerental sheets in form of lists, sketches, or drawings may be used, provided (1)size 8 1/2 in. x 11 in.. (2) informa-tion in tems 1 through 6 on this eport is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0863913 Sheet 2 of 2 FORM NIS-2 BACK) 9, Remarks Manutacturer's data reports are traceable by Exelon work order Package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the reporl are correct and this reolacement coniorms to the rules of the ASME Code, Section Xl. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . J.H. Kramer fengineer) Date Mav7 -2003 O Aer or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT Of Hartford. CT have inspected the components described in this Owner's Report during the period le MAY C:>I to 9 I(AY o3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing Ihis certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his empyer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection i gofg - g  ; G 2 Commissione PA-2497 IN &A Inspedor's Sgnae / National Board, State, Province, and Endorsements Date 9 H Y X s (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Exelon Generation Comroan. LLC Date Mav 52003 Name 200 Exelon Way. Kennett Square, PA 19346 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatogaa PA 19464-2300 Work Order No. R0896042 Address Repair Organization P.O. No., Job No. etc.
3. Work Pertormed by Exelon Nuclear Type Code Symbol Stamp NIA Name Authorization No. N/A P.O. Box 2300. Sanatoga PA 19464-2300 Expiration Date NIA Address
4. Identification of System Residual heat removal ,

(Svstem 051) Line No. GBB-219 Valve 051-2F089D S. (a) Applicable Construction Code ASME ll 19 71 _Edition, Winter 1973 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19j 89

6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manutacturer Serial No. Board No. Identification Replacement Stamped (Yes or

_ _ _ __ __ _ __ _ __ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ ~~~~~~ ~~ ~~ ~~~No) 4" Valve

  • 114-33943 051_2F090D Velan 7447 N/A PCW 184729 2001 REPLACEMENT YES Disc 1raceability per Exelon stock code number.
7. Description of work: Valve disc reolaced.
8. Tests conducted: Hydrostatic o Pneumatic c. Nominal Operating Pressure I:

Other __162_psi Test Temp. NIA_ 'F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the lop of this torm.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

WJO No. R0896042 Sheet 2 of 2 FORM NIS2 (BACK)

9. Remarke Manufactuter's data reDorts are traceable by Exelon work order package.

Applicable Manufacturer's Data Reports to be antached CERTIFICATE OF COMPLIANCE We certily that the statements made in the report are correct and this reolacernent conforms to the rules of the ASME Code,Section XI. (repair or replacement)

Type Code Symbol Stamp NA Certificate of Authorization No NA Expiration Date NA Signed r *J.H Kramef (enaineer) Date May .2003 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsyvania and employed by HSBCT Of Hartford. CT have inspected the components described in this Owners Repoul during the period 5 AL) 02 to Y A4-CY C _. and state that to the best ot my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ot any kind arising from or connected with this inspection.

Commissions PA-2497 LN & A Inspectors Signature National Board, State, Province, and Endorsements Date tA I IV A -

(12/82)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by lhe Provisions of the ASME Code Section XI

1. Owner Exelon Generation Company, LLC Date May 12. 2003 Name Sheet 1 of 2 200 Exelon Wav. Kennett Sauare. PA 19348 Address
2. Plant Limerick Generatina Station Unn 2 Name P.O. Box 2300. Sanatoga. PA 19464-2300 Work order # C01 94544 Address Repair Organization P.O. No., Job No. etc.
3. Work Perfotmed by Exelon Nucleat Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. der.ti,,cZ40. c, Syse,M !c,e Srav (SvMlemM2 ) Line No. HBB-220 PSV-052-2F032A
5. (a) Applicable Construction Code ASME III 192A__Ediion, Winter 1974 Addenda, N-416-1 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19j_
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped PSV-052- Kunkle 133975-10-1 N/A
  • 11477945 1992 Replacement Yes 2F032A PO# 655922 2" NPS Pipe Sanvk Steel Heat# N/A
  • 11490 N/A Replacement No 462117 ~~POWJ 628235 2' NPS Flange WFI Nuclear Heat# N/A
  • 11415135 N/A Replacernent No 1088ANE1 PO# 181464 Traceability per Exelon part code number.
7. Description of Work Replaced Core Spray pump suction relief valve and inlet pipe filanoe.
8. Tests conducted: Hydrostatic C Pneumatic [ Nominal Operating Pressure Other _ Fressure 24 Feet Supwression Dool level Test Temp. N/A F.

NOTE: Supplermental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion in items I through 6 on this reporl is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82%, This Form (E00030) may be oblained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

Work Order# C0194544 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks: Manutacturer's datE reports are traceable by Exelon work order package.

Applicable Manufacturer's Data Reports to be attached Relief valve manufactured in accordance with ASME I 1974 edition with Summer 1974 addenda.

CERTIFICATE OF COMPLIANCE We certify that the stalements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . . J.H. Kramer engineer Date May12, 2003 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of PennsYlvania and employed by HSBCT Of Hartford CT have inspected the components described in this Owners Report during the period A/ i)Z . 3;CC 0to R . 11'l. oS9 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insp ection -

Commissions PA-2497 I.N 8 A InspectdfS ignatulft National Board, State, Province, and Endorsements Date__ t2Z 13-0i4* 20 g,3-(12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As fiequired by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Company. LLC Date June 16. 2003 Name Sheet 1 of, 2 200 Exelon Way. Kennett SQuare. PA 19346 Address
2. Plant I imprirk GeinPratinn Stntin Unit Name P.0 Box 2300. Sanatoqa. PA 19464-2300 Work order # R0871833 Address Repair Organi2alion P.O. No., Job No. etc.
3. Work Perlormed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanaloaa. PA 19464-2300 Expiration Date N/A Address
4. Identific3tin of Syste-M Cow rSwv (System-052 *. Valve052-2F0306
5. (a) Applicable Construction Code ASME III 1974 Edition, Winter 1974 Addenda, N-416-1 Code Case (b) Applicable Edition of Section Xl Utilizerd for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped Valve 052- Edward Vogl 84ASH N/A 114-98110 2001 Replacement Yes 2F030B PO# 257797-348101 2- NPS Pipe U.S. Steel Heat N/A
  • 114-90039 N/A Replacement No A42035 PO# 169202 Iraceability per Exelon pan cooe numDez.
7. Description of Work Replaced 2" check valve and adiacent piPe. Removed and rewelded dpie support.
8. ests conducled: Hydrostatic Pneumatic Nominal Operating Pressue U Othe _ Pressue 262 PSI lest 1 emp. N/A -F.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 1/2 in. x 11 in., (2) informa-lion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12182) This Form (E00030) may be obtained trom the Order Dept., ASME. 345 E.47th St., New York, N.Y. 10017

Work Order# R0871833 Sheet 2 of 2 FORM NIS-2 (BACK)

9. Remarks., Manufacturer's data reports are traceable by Exelon work order package.

Applicable Manufacturer's Data Reports to be attached Relief valve manulactured in accordance with ASME IlIl, 1974 edition with Summer 1975 addenda.

Per code case N416-1. NDE completed in accordance with ASME lIl. 1992 edition. Presswe testino completed in accordance with ASME Xi. 1992 edition.

CERTIFICATE OF COMPLIANCE We certify that the stalements made in the repon are correct and this replacement coniorms to the rules of the ASME Code. Section Xi Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ( . 1 . - J.H. Kramer .enaineer Date June 16, 2003

)Owner or Owne s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commissiDn issued by the National Board of Boiler and Pessire Vessel Inspectors and the State or Province o Pennsylvania and employed by HSBCT of Hartford. CT _ have inspected the components described in this Owner's Report during the period _ X. C)C T CXZ to I&6 .TVMI* e5 ,and state that to the best ot my knowledge and belief. he Owner has performed examinations and taken corrective measwtes described in this Owner's Report in accordance with the requirements ot the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and coriective measues described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________________________ Commissions PA-2497 L.N A inspectors Signature National Board, State, Province, and Endorsements Date /v4 At- 2003.

(12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Generation Companv. LLC Date May 30. 2003 Name 200 Exelon Way. Kennett Square. PA 19346 Sheet 1 of . _

Address

2. Plant Limerick Generatina Station Unit Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Work Order No. R0872422 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. SanatoQa. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Containment Atmosphere Control (System Line No. HBD-B1E Vacuum Breaker PSV-057-237B-1 Q571
5. (a) Applicable Construction Code ASME lIt 19 71 iEdition, Summer 1973 Addenda, N/A Code Case (b) Applicable Eddion of Section Xl Utilized for Repairs or Replacements 1S 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped (Yes or No) 24' Vacuum Anderson-Breaker PSV- Greenwood N/A N/A N/A N/A Repair Nc 057-237B-1 1- 1- -.

t I

__________________________ -. -. A

7. Description of work: Repaired orifice plate threads by weld repair
8. Tests conducted: Hydrostatic D Pneumatic Nominal Operating Pressure 0 Other o N/A psi Test 1emp. N/A IF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained rom the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

W/O No. R0872422 Sheet 2 o 2 FORM NIS-2 (BACK)

9. Remarks Post repair testing completed by ST-2-060-400.2, ST-6-060-360-2 and ST-6-060-760-2 Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this reoair conforms to the rules of the ASME Code,Section XI. (repair or replacement)

Type Code Symbol Stamp NA Certrficate of Authorization No. NA Expiration Date _NA Signed C J.H. Kramer fenoineer) Date May31. 2003 Ofzer or Ownier s Designee, TRkl CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvanb and employed by HSBCT Of Hartford. CT have inspected the components described in this Owners Repol during the period in MAIR Z to q TLr'm,4E C3 ,and state that to the best ot my knowledge and belief, the Owner has periormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures diescribed in this Owner's Report. Furthermore, neiher the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,. , >

  • Kt 2 +? 7 Commissions PA-2497 I.N & A Inspectors Signature ,/ National Board, State. Province, and Endorsements Date 3  ;,.......j A cLQQ3 (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon generation Company. LLC Date May 30. 2003 Name 200 Exelon Way. Kennett Scuare. PA 19348 Sheet 1 of 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoaa PA 19464-2300 Action Reauest No. A1361522 AddrfE Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Snubbers (System 103 ) Line No. Various, See Name of Component
5. (a) Applicable Construction Code ANSI B31.7 1969 EtEdion_ March I11971 Addenda. N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 19___89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped DCA-201-H060 BASIC-PSA 42196 N/A PSA-3 N/A Replacement No SNUBBER
7. Description of Work Replaced mechanical shock arrester snubbers
8. ests conducted: Hydrostatic _ Pneumatic _ Nominal Operating Pressure _

Other Pressure NIA _.psi Test Temp. N/A *F.

NOTE: Supplemental sheets in orm of lists, sketches, or drawings may be used, provided (1) size 8 12 in. x 1I in.. (2) intorma-tion in items 1 through 6 on this report is included on each sheet, aid (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(I12182j This Form (E0030) may be obtained from the Order Dept., ASME, 345 E.47th St.. New York, N.Y. 10017

Il A/R No. Al 361 522 Shee 2 of 2 FORM NIS.2 (BACK)

9. Remarks Pacific Scientific BASIC-PSA snubbers are manufactured to ASME lIl. 1977 edition with winter 1977 addenda.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. repair of replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed *H.Kramer.Enineer

.9 Date May 30. , 2003 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT of Hartford, CT _ _ have inspected the components described inthis Owners Report duringthe period JY *AR C3 to . TL; %It:.. cs ,andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither lhe Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ture inspenUo o mmissiont PA-2497 IN S A Inspecors Signalure National Board. State. Province, and Endorsements Date ' ' i*j k (12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Qeneration Company, LLC Date May 30. 2003 Name 200 Exelon Way, Kennett Souare. PA 1934E Sheet 1 ot 2 Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoga. PA 19464-2300 Action Reauest No. Al 361523 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuciear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga PA 194642300 Expiration Date NJA Address
4. Identification of System Snubbers (System 103) Line No. Various. See Name of Component
5. (a) Applicable Construction Code ANSI 31.7 1969 Editon. March 10. 1971 Addenda, NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped EBB-209-H015 BASIC-PSA 42196 N/A PSA-3 N/A Replacement No SNUBBER GBB-217-H015 BASIC-PSA 42203 N/A SAUBO NIA Replacement No SNUBBER GBB-219-H093(B) BASIC-PSA 42213 NIA SNUBBER N/A Replacement No HBB-210-H021(A) BASIC-PSA 42197 N/A PSA-3 Replacement No SNUBBER NARpaeetN HBC-293-H012 BASIC-PSA 41413 NIA PSA-1 NIA Repbcement l NA SNUBBER NARpaeetN
7. Description of Work Replaced mechanical shock arrester snubbers
8. Tests conducted: Hydrostatic _ Pneumatic _ Nominal Operating Pressure _

Othet Pressure N/A psi Test Temp. N/A OF.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size 8 112 in. x 11 in., (2) informa-tion h items 1 through 6 on this report is included on each sheet, and (3) each sheet is nutnbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E.47th St.; New York, N.Y. 10017

AIR No. A1361 523 Sheet 2 of 2 FORM NIS.2 (BACK)

9. Remarks Pacific Scientific. BASIC-PSA snubbers are manufactured to ASME 1I1.1977 edition wth winter 1977 addenda Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certity that the slatemerds made in the report are correct and this tenlacement conforms to the rules of the ASME Code. Section Xl. repair of replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Dsn Date May 30. .2003 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSBCT - of Hartford. CT have inspected the components described in this Owner's Report during the period i "LAZ QOA to .; jL)&/ 031 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code. Section Xl By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinalions and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

f o m miomissions PA-2497 I.N & A Inspecto Signature National Board, State, Province, and Endorsements Date . . -JLOjt;.-

(12182)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon generation Companv. LLC Date May 15. 2003 Name 200 Exelon Way, Kennett SQuare. PA 19346 Sheet 1 of 3 Address
2. Plant Limerick Generatino Station Unit 2 Name P.O. Box 2300. Sanatoaa. PA 19464-2300 Action ReQuest No. Al 361529 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Exelon Nuclear Type Code Symbol Stamp N/A Name Authorization No. N/A P.O Box2300 Sanatora PA 19464-2300

.. _ . .. _w. _ ___ . __ .. _.___ ................ . _ . _ . _ _ _ _

Expiration Date N/A Address

4. dentificution of Sysiem Snuboers (System 103 Line No. Various, See Name of rnmrnentn
5. (a) Applicable Construction Code ANSI B31.7 1969 Edition, March 10. 1971 Adder nda N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Built Replaced, or Code Component Manufacturer Serial No. Board No. Identification Replacement Stamped GBB-213-H013 (A) BASIC-PSA 42195 N/A PSA-3 N/A Replacement Nc SNUBBER GBB-213-H013 (B) BASIC-PSA 41840 N/A SNUBER NIA Replacernent Nc GBB-213-H054 BASIC-PSA 42209 N/A PSA-10 N/A Replacement No SNUBBER NARpaeetN GBB-218-HO59 (A) BASIC-PSA 42216 NIA PSA-10 SNUBBER N/A Replacement No GBB-218-HOo8 BASIC-PSA 42217 N/A PSA-10 GBB-218-H64(B) BASIC-PSA 4215 NIA SNUBBER N/A Replacement No GBB-218-H078 (A) BASIC-PSA 42216 N/A PSA-10 N/A Replacement No SNUBBER A),-.L h.nl-A m-rhnini ehnek rrecter niihhorc
7. Description of%Fv-O -DLJ--R WlD,WltA  ; 1tZ7§;lc ItF}.
8. Tests conducted: Hydrostatic_ Pneumatic _ Nominal Operating Pressure _

Other Pressure NIA psi Test Temp. NIA 'F.

NOTE: Supplemental sheets in form of iists, sketches, or drawings may be used, provided (1) size 8 112 In. x 11 in., (2) infc:rna-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(I12182) This Form (E00030) may be oblained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017

AIR No. A1361529 Sheet 2 of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon generation Company. LLC Date May 15. 2003 Name 200 Exelon Way, Kennett Sauare. PA 1934 Sheet 2 of Address
2. Plant Limerick Generating Station Unit 2 Name P.O. Box 2300. Sanatoca. PA 19464-2300 Action Reguest No. Al 361529 Address Repair Organization P.O. No., Job No. etc.
3. Wcrk Pcr--.cd ty Ee!on Nuclear Tvn Cie Svrbn St51n. N/A Name Authorization No. N/A P.O. Box 2300. Sanatoga. PA 19464-2300 Expiration Date N/A Address
4. Identification of System Snubbers (System 103) Line No. Various. See Name of Component
5. (a) Applicable Construction Code ANSI 831.7 199_Edition, March10 1971 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

A/R No. Al 361529 Sheet 3 of 3 FORM NIS-2 (BACK)

9. Remarks Pacific Scientific, BASIC-PSA snubbers are manufactured to ASME I1L1977 edhion wih winter 1977 addenda.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the eport are correct and this redlacement conforms to the rules of the ASME Code,Section XI. repair of replacement lype Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed J. H. Kramer, Engineer Date Mav 1 . , 2003 nter or Owners Designee, itle CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvia and employed by HSBCT of Hartford, CT have inspected the components described in this Owner's Report during the period , I 4AZ C2 to 14 MAy C 3e, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective rmeasures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________________________________commissions PA-2497 L.N a A Inspectors Signature National Board. State, Province, and Endorsements Date ___ _A _ ___ __

(12/82)