L-2022-182, Emergency Response Data System (Eros) Changes

From kanterella
(Redirected from L-2022-182)
Jump to navigation Jump to search
Emergency Response Data System (Eros) Changes
ML22321A113
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 11/17/2022
From: Cashwell C
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
L-2022-182
Download: ML22321A113 (1)


Text

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-0001 Re:

Turkey Point Unit 3 Docket No. 50-250 Emergency Response Data System (EROS) Changes November 17, 2022 L-2022-182 10 CFR 50 Appendix E Pursuant to 10 CFR 50, Appendix E, VI, 3.a, "Maintaining the Emergency Response Data System," this letter notifies the NRC of a change to an existing data point to/from the Emergency Response Data System (EROS) Data Point Library Reference File for Turkey Point Unit 3.

The Turkey Point Unit 3 Spent Fuel Pit ventilation system incorporates a dedicated radiation monitor. A modification to replace RAD-3-6418 with an upgraded design has been completed, resulting in a revised data point ID and instrument ranges. summarizes the preceding EROS data point, the new EROS data point, and the corresponding library reference file.

The change was completed on November 3, 2022. This information is provided pursuant to 10 CFR 50, Appendix E, VI, 3.a, which requires NRC notification within 30 days after the changes are completed.

Please contact Ms. Cynthia Cashwell, Turkey Point Regulatory Affairs Manager, at 305-246-1631 with any questions.

Sincerely, Cynthia Cashwell Regulatory Affairs Manager Turkey Point Nuclear Plant cc:

Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant Florida Power & Light Company 9760 SW 344th St., Homestead, FL 33035

Description Units Spent Fuel Pit High

µCi/cc Range Description Units Spent Fuel Pit High

µCi/cc Range Florida Power & Light Company 9760 SW 344th St., Homestead, FL 33035 Prece mg om d"

ERDS P. t Low Range High Range 1 E-1 1E+5 New ERDS Point Low Range High Range 1 E-4 1E+5 L-2022-182 Page 1 of 2 TP3 Data Point R6418HR_A TP3 Data Point R6418HB_V L-2022-182 Page 2 of 2 TP3 DATA POINT LIBRARY REFERENCE FILE Date:

02/07/2022 Reactor Unit:

TP3 Data Feeder:

N/A NRC EROS Parameter:

NL Point ID:

R6418HB V Plant Spec Point Desc:

U3 Fuel Pool Gas Gamma Hi Rng Generic/Cond Desc:

Radioactivity Of Released Gases Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

N/A Minimum Instr Range:

1.0E-4 Maximum Instr Range:

1.0E+5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

p Number of Sensors:

1 How Processed:

Data Link Sensor Locations:

U3 Spent Fuel Pool Vent Stack Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply Cut-N/A off Power Level:

NI Detector Power Supply Turn-N/A On Power Level:

Instrument Failure Mode:

As-ls Temperature Compensation For N/A DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The monitoring system is a combination of interconnected skids (a low range and a high range noble gas monitors) with continuous particulate and iodine sampling capability.

The low range spent fuel pool gas detector (RAD-3-641 BA) is a beta scintillation detector and the high range detector (RAD-3-6418B) is a flow through ionization chamber detector.

Florida Power & Light Company 9760 SW 344th St., Homestead, FL 33035