FENOC Beaver Valley Power Station Route 168 Ne a

P.O. Box 4 FirstEnergy Nuclear Operating Company Shippingport, PA 15077-0004 Mark B. Bezilla 724-682-5234 Site Vice President Fax: 724-643-8069 August 7, 2002 L-02-086 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Emergency Response Data System (ERDS)

The enclosed ERDS Data Point Library (DPL) changes are being submitted as required by 10 CFR 50, Appendix E, Section VI.3.a.

The changes have already been implemented on plant computers that provide data to the ERDS computer and consist of the following:

1. Intermediate Range Detector 1 Log Flux high alarm setpoint was changed from 8.OE-4 to 9.OE-4 amps (Mode 1)
2. Intermediate Range Detector 2 Log Flux high alarm setpoint was changed from 7.OE-4 to 7.4E-4 amps (Mode 1)

Previously, the reported values for these setpoints reflected plant operating Mode 1.

However, the plant computer at Beaver Valley 1 implements three different intermediate range detector high alarm setpoints corresponding to plant operating Modes 1, 2, and 3 through 6.

Alarm status data is provided to ERDS relative to the prevailing plant operating mode at the time the data is transmitted. Therefore, the attached DPL sheets have been revised to show all three setpoints for each detector, rather than the single Mode 1 setpoint previously reported.

The change described above includes a change that was made in April 2002, but not reported at that time. This omission has been entered in the FENOC corrective action system for evaluation and correction.

Beaver Valley Power Station, Unit No. 1 Emergency Response Data System (ERDS)

L-02-086 Page 2 If you have any questions concerning the DPL changes, please contact Mr. Larry R.

Freeland, Manager, Regulatory Affairs/Corrective Action at 724-682-5284.

Sincerely, Mark B. Bezitla Attachments c:

Mr. D. S. Collins, NRR Project Manager Mr. J. R. Jolicoeur, USNRC Incident Response Division Mr. D. M. Kern, NRC Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator

BEAVER VALLEY POWER BV Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number Of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

STATION ERDS DATA POINT LIBRARY

'1 ERDS INPUT 08/02/2002 BVl IPC NI-INTER-RNG N0035A INTERMEDIATE RANGE DET 1 LOG FLUX NUC INSTRUMENTS, INT RANGE A

AMP LOG Y = 8/5 (VOLTS)

-5 l0E-11 10E-3 N/A N/A S

N/A SEE SEE 2/4 3/4 LOW UNIQUE SYSTEM DESCRIPTION FIELD UNIQUE SYSTEM DESCRIPTION FIELD PWR RNG>I0%

PWR RNG<I0%

N N/A INTERMEDIATE RANGE LEVEL INDICATION FROM lbE-11 TO 10E-3 AMPS CORRESPONDS TO ABOUT 10E-6 % TO 10E2 % FULL RATED POWER.

POWER RANGE LEVEL INDICATION WILL NOT COME ON SCALE UNTIL THE REACTOR POWER LEVEL RISES TO ABOUT 10E-5 AMPS INTERMEDIATE RANGE LEVEL.

(-1%

FULL POWER).

N-35 (SEE ATTACHED NIS DETECTOR LOCATION DWG.)

OP MANUAL CHAPTER 2.

MODE 1 HIGH ALARM = 9.0E-04 AMP; MODE 2 HIGH ALARM = 7.0E-04 AMP; MODES 3-6 HIGH ALARM = 1.3E-04 AMP

BEAVER VALLEY POWER BN Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number Of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

STATION ERDS DATA POINT LIBRARY l ERDS INPUT 08/02/2002 BV1 IPC EXTRA4 N0036A INTERMEDIATE RANGE DET 2 LOG FLUX NUC INSTRUMENTS, INT RANGE A

AMP LOG Y = 8/5 (VOLTS)

-5 lOE-11 10E-3 N/A N/A S

N/A SEE SEE 2/4 3/4 LOW UNIQUE SYSTEM DESCRIPTION FIELD UNIQUE SYSTEM DESCRIPTION FIELD PWR RNG>I0%

PWR RNG<I0%

N N/A INTERMEDIATE RANGE LEVEL INDICATION FROM lOE-11 TO 10E-3 AMPS CORRESPONDS TO ABOUT 10E-6 % TO 10E2 % FULL RATED POWER.

POWER RANGE LEVEL INDICATION WILL NOT COME ON SCALE UNTIL THE REACTOR POWER LEVEL RISES TO ABOUT 10E-5 AMPS INTERMEDIATE RANGE LEVEL.

F 1 % FULL POWER).

N-36 (SEE ATTACHED NIS DETECTOR LOCATION DWG.)

OP MANUAL CHAPTER 2 MODE 1 HIGH ALARM = 7.4E-04 AMP; MODE 2 HIGH ALARM = 7.OE-04 AMP; MODES 3-6 HIGH ALARM

= 1.3E-04 AMP

Commitment List The following list identifies those actions committed to by FirstEnergy Nuclear Operating Company (FENOC) for Beaver Valley Power Station (BVPS) Unit No. 1 in this document.

Any other actions discussed in the submittal represent intended or planned actions by Beaver Valley. These other actions are described only as information and are not regulatory commitments. Please notify Mr. Larry R. Freeland, Manager, Regulatory Affairs/Corrective Actions, at Beaver Valley on (724) 682-5284 of any questions regarding this document or associated regulatory commitments.

Commitment Due Date None N/A