| | | Reporting criterion |
|---|
| 05000302/LER-1982-001-03, /03L-0:on 820106,core Flood Tank B Was Discovered W/Level Below Tech Spec Requirements.Caused by Loss of Water in Ref Legs of Level Transmitters.Legs Filled. Transmitters to Be Replaced | /03L-0:on 820106,core Flood Tank B Was Discovered W/Level Below Tech Spec Requirements.Caused by Loss of Water in Ref Legs of Level Transmitters.Legs Filled. Transmitters to Be Replaced | |
| 05000302/LER-1982-001, Forwards LER 82-001/03L-0 | Forwards LER 82-001/03L-0 | |
| 05000302/LER-1982-002-03, After Removing MUP-1B Pump Casing by MP-126,discovered Pump Casing Was Seismic Anchor.Caused by Failure of Procedure MP-126 to Identify Required Seismic Evaluation.Maint Procedure Revised | After Removing MUP-1B Pump Casing by MP-126,discovered Pump Casing Was Seismic Anchor.Caused by Failure of Procedure MP-126 to Identify Required Seismic Evaluation.Maint Procedure Revised | |
| 05000302/LER-1982-002, Forwards LER 82-002/03L-0 | Forwards LER 82-002/03L-0 | |
| 05000302/LER-1982-003, Forwards LER 82-003/01T-0 | Forwards LER 82-003/01T-0 | |
| 05000302/LER-1982-003-01, /01T-0:on 820128,RCS Pressure Boundary Leak Found in Valve Body of MUV-43.Caused by Thermally Induced Cyclic fatigue.MUV-43 Removed.New Valve Will Be Installed in Improved Location | /01T-0:on 820128,RCS Pressure Boundary Leak Found in Valve Body of MUV-43.Caused by Thermally Induced Cyclic fatigue.MUV-43 Removed.New Valve Will Be Installed in Improved Location | |
| 05000302/LER-1982-004, Forwards LER 82-004/01T-0 | Forwards LER 82-004/01T-0 | |
| 05000302/LER-1982-004-01, /01T-0:on 820129,during Visual Insp of RCP-A Seal Package,Crack in Weld Between Third Stage Cavity & Vent Pipe Discovered.Caused by Crack in Weld Joint Where Vent Pipe Meets Cavity.Rebuilt Spare Seal Package Installed | /01T-0:on 820129,during Visual Insp of RCP-A Seal Package,Crack in Weld Between Third Stage Cavity & Vent Pipe Discovered.Caused by Crack in Weld Joint Where Vent Pipe Meets Cavity.Rebuilt Spare Seal Package Installed | |
| 05000302/LER-1982-005-03, /03L-0:on 820119,175 & 33-ft Wind Direction & Ambient Temp Monitoring Channels Found Out of Calibr.Caused by Instrument Drift.Instruments Recalibr & Returned to Svc 820126.Meteorological Monitoring Tower Design Under Review | /03L-0:on 820119,175 & 33-ft Wind Direction & Ambient Temp Monitoring Channels Found Out of Calibr.Caused by Instrument Drift.Instruments Recalibr & Returned to Svc 820126.Meteorological Monitoring Tower Design Under Review | |
| 05000302/LER-1982-005, Forwards LER 82-005/03L-0 | Forwards LER 82-005/03L-0 | |
| 05000302/LER-1982-006-03, /03L-0:on 820125,during Weekly Battery Check, SP-520,on Station Battery 3B,pilot Cell 115 Failed to Meet Acceptance Criteria.Caused by Dissipation of Charge Between Surveillances.Battery Recharged & Returned to Svc | /03L-0:on 820125,during Weekly Battery Check, SP-520,on Station Battery 3B,pilot Cell 115 Failed to Meet Acceptance Criteria.Caused by Dissipation of Charge Between Surveillances.Battery Recharged & Returned to Svc | |
| 05000302/LER-1982-006, Forwards LER 82-006/03L-0 | Forwards LER 82-006/03L-0 | |
| 05000302/LER-1982-007, Forwards LER 82-007/03L-0 | Forwards LER 82-007/03L-0 | |
| 05000302/LER-1982-007-03, /03L-0:on 820123,starting Air Pressure for Emergency Diesel Generator B Too Low for Automatic Start & Air Pressure Low Alarm Did Not Actuate.Caused by EGV-16,air Tank Blowdown Valve Not Fully Closed & Alarm Malfunction | /03L-0:on 820123,starting Air Pressure for Emergency Diesel Generator B Too Low for Automatic Start & Air Pressure Low Alarm Did Not Actuate.Caused by EGV-16,air Tank Blowdown Valve Not Fully Closed & Alarm Malfunction | |
| 05000302/LER-1982-008-03, /03L-0:on 820127,RCS Leak of Less than 0.1 Gallon Per Minute Discovered in Letdown Cooler A.Caused by tube-to-shell Leak in Cooler.Letdown Cooler a Isolated & Will Be Replaced W/Spare Cooler | /03L-0:on 820127,RCS Leak of Less than 0.1 Gallon Per Minute Discovered in Letdown Cooler A.Caused by tube-to-shell Leak in Cooler.Letdown Cooler a Isolated & Will Be Replaced W/Spare Cooler | |
| 05000302/LER-1982-008, Forwards LER 82-008/03L-0 | Forwards LER 82-008/03L-0 | |
| 05000302/LER-1982-009-03, /03L-0:on 820204,containment Isolation Valves MUV-259 & MUV-260 Failed to Close During Cold Shutdown Testing.Caused by Insufficient Torque Switch Settings.Torque Switch Setting increased.MP-402 Will Be Revised | /03L-0:on 820204,containment Isolation Valves MUV-259 & MUV-260 Failed to Close During Cold Shutdown Testing.Caused by Insufficient Torque Switch Settings.Torque Switch Setting increased.MP-402 Will Be Revised | |
| 05000302/LER-1982-009, Forwards LER 82-009/03L-0 | Forwards LER 82-009/03L-0 | |
| 05000302/LER-1982-010-03, /03L-0:on 820217,connector RMG-14 Failed & Declared Inoperable.Caused by Leak or Leaks in Roof Allowing Water to Enter Electrical Connector.Connector Cleaned & Repaired & Will Be Waterproofed | /03L-0:on 820217,connector RMG-14 Failed & Declared Inoperable.Caused by Leak or Leaks in Roof Allowing Water to Enter Electrical Connector.Connector Cleaned & Repaired & Will Be Waterproofed | |
| 05000302/LER-1982-010, Forwards LER 82-010/03L-0 | Forwards LER 82-010/03L-0 | |
| 05000302/LER-1982-011, Forwards LER 82-011/03L-0 | Forwards LER 82-011/03L-0 | |
| 05000302/LER-1982-011-03, /03L-0:on 820224,during Performance of SP-112,RC Flow,Channel a Was Found Out of Calibr.Caused by Linear Voltage Differential Transformer Shorting Out.Transformer Replaced & Instrument Calibr | /03L-0:on 820224,during Performance of SP-112,RC Flow,Channel a Was Found Out of Calibr.Caused by Linear Voltage Differential Transformer Shorting Out.Transformer Replaced & Instrument Calibr | |
| 05000302/LER-1982-012, Forwards LER 82-012/03L-0.Detailed Event Analysis Encl | Forwards LER 82-012/03L-0.Detailed Event Analysis Encl | |
| 05000302/LER-1982-012-03, /03L-0:on 820226,emergency Diesel Generator a Would Not Start After Mechanical Maint on Exhaust Manifold. Caused by Restricted Air Lines,Filters & Strainers.Air Start Valves,Filters & Strainers Cleaned | /03L-0:on 820226,emergency Diesel Generator a Would Not Start After Mechanical Maint on Exhaust Manifold. Caused by Restricted Air Lines,Filters & Strainers.Air Start Valves,Filters & Strainers Cleaned | |
| 05000302/LER-1982-013, Forwards LER 82-013/03L-0.Detailed Event Analysis Encl | Forwards LER 82-013/03L-0.Detailed Event Analysis Encl | |
| 05000302/LER-1982-013-03, Leak Discovered on Pressure Side of MUV-292 in Heat Affected Area of Weld. Caused by Vibration.Supports/Restraints Added to Makeup Sys. Vibration Eliminated | Leak Discovered on Pressure Side of MUV-292 in Heat Affected Area of Weld. Caused by Vibration.Supports/Restraints Added to Makeup Sys. Vibration Eliminated | |
| 05000302/LER-1982-014, Forwards LER 82-014/03L-0 | Forwards LER 82-014/03L-0 | |
| 05000302/LER-1982-015, Forwards LER 82-015/03L-0 | Forwards LER 82-015/03L-0 | |
| 05000302/LER-1982-015-03, /03L-0:on 820204,reactor Bldg Pressure Transmitter Isolation Valve V-1 Shut in Mode 5.Caused by Undocumented Valve Closing.Valve Opened | /03L-0:on 820204,reactor Bldg Pressure Transmitter Isolation Valve V-1 Shut in Mode 5.Caused by Undocumented Valve Closing.Valve Opened | |
| 05000302/LER-1982-016, Forwards LER 82-016/03L-0 | Forwards LER 82-016/03L-0 | |
| 05000302/LER-1982-016-03, /03L-0:on 820304,failed to Properly Complete 10CFR50.59 Review on Planned Mod Resulting in Approval of Mod to Sys That Could Have Allowed Operation W/Response Time Greater than Tech Spec Limit.Caused by Human Error | /03L-0:on 820304,failed to Properly Complete 10CFR50.59 Review on Planned Mod Resulting in Approval of Mod to Sys That Could Have Allowed Operation W/Response Time Greater than Tech Spec Limit.Caused by Human Error | |
| 05000302/LER-1982-017-03, /03L-0:on 820307,reactor Bldg Pressure Indicator Fluctuated Between 10 & 20 Lb.Caused by Water in Junction Box & Flex Cable.Junction Box & Flex Cable Dried Out & Instrument Calibr & Sealed | /03L-0:on 820307,reactor Bldg Pressure Indicator Fluctuated Between 10 & 20 Lb.Caused by Water in Junction Box & Flex Cable.Junction Box & Flex Cable Dried Out & Instrument Calibr & Sealed | |
| 05000302/LER-1982-017, Forwards LER 82-017/03L-0 | Forwards LER 82-017/03L-0 | |
| 05000302/LER-1982-018-03, /03L-0:on 820308,following Recirculation of Boric Acid Sys Tanks,Both Tanks Were Isolated.Cause Attributed to Procedural Deficiency.Procedure OP-403 Revised | /03L-0:on 820308,following Recirculation of Boric Acid Sys Tanks,Both Tanks Were Isolated.Cause Attributed to Procedural Deficiency.Procedure OP-403 Revised | |
| 05000302/LER-1982-018, Forwards LER 82-018/03L-0 | Forwards LER 82-018/03L-0 | |
| 05000302/LER-1982-019-03, /03L-0:on 820301,while Performing Housekeeping,Air Start Line to Number 5 Cylinder on Emergency Diesel Generator B Found Parted.Caused by Fatigue on Cylinder Air Start Line.Line Repaired | /03L-0:on 820301,while Performing Housekeeping,Air Start Line to Number 5 Cylinder on Emergency Diesel Generator B Found Parted.Caused by Fatigue on Cylinder Air Start Line.Line Repaired | |
| 05000302/LER-1982-019, Forwards LER 82-019/03L-0 | Forwards LER 82-019/03L-0 | |
| 05000302/LER-1982-020-03, /03L-0:on 820305,while Reviewing Surveillance Data,Nuclear Overpower,Rcs Flow & Axial Power Imbalance, Bistable in Channel C Discovered Out of Tolerance.Caused by Instrument Drift.Instrument Recalibr | /03L-0:on 820305,while Reviewing Surveillance Data,Nuclear Overpower,Rcs Flow & Axial Power Imbalance, Bistable in Channel C Discovered Out of Tolerance.Caused by Instrument Drift.Instrument Recalibr | |
| 05000302/LER-1982-020, Forwards LER 82-020/03L-0 | Forwards LER 82-020/03L-0 | |
| 05000302/LER-1982-021-03, /03L-0:on 820219,while Using SP-221 (Startup Feedwater Valve Air Accumulator Leak Test) for Maint Trouble Identification,Feedwater Valve (FWV-39) Failed to Meet Surveillance Criteria.Cause Undetermined | /03L-0:on 820219,while Using SP-221 (Startup Feedwater Valve Air Accumulator Leak Test) for Maint Trouble Identification,Feedwater Valve (FWV-39) Failed to Meet Surveillance Criteria.Cause Undetermined | |
| 05000302/LER-1982-021, Forwards LER 82-021/03L-0 | Forwards LER 82-021/03L-0 | |
| 05000302/LER-1982-022, Forwards LER 82-022/03L-0 | Forwards LER 82-022/03L-0 | |
| 05000302/LER-1982-022-03, /03L-0:on 820321,emergency Feedwater Ultrasonic Flow Indicator Not Functioning.Caused by Failed Power Supply.Ultrasonic Flow Transmitter Will Be Replaced W/ Conventional Flow Transmitter | /03L-0:on 820321,emergency Feedwater Ultrasonic Flow Indicator Not Functioning.Caused by Failed Power Supply.Ultrasonic Flow Transmitter Will Be Replaced W/ Conventional Flow Transmitter | |
| 05000302/LER-1982-023-03, /03L-0:on 820320,mainsteam Valve MSV-130, Discovered Leaking on High Pressure Side.Caused by Seal Ring Failure.Valve Removed,Cleaned & Ring Replaced | /03L-0:on 820320,mainsteam Valve MSV-130, Discovered Leaking on High Pressure Side.Caused by Seal Ring Failure.Valve Removed,Cleaned & Ring Replaced | |
| 05000302/LER-1982-023, Forwards LER 82-023/03L-0 | Forwards LER 82-023/03L-0 | |
| 05000302/LER-1982-024, Forwards LER 82-024/03L-0 | Forwards LER 82-024/03L-0 | |
| 05000302/LER-1982-024-03, /03L-0:on 820321,during Normal Operation,Air Temp Delta T Meteorological Monitoring Instrumentation Discovered Inoperable Contrary to Tech Spec.Caused by Failed Aspirating Fan Motor.Motor Replaced | /03L-0:on 820321,during Normal Operation,Air Temp Delta T Meteorological Monitoring Instrumentation Discovered Inoperable Contrary to Tech Spec.Caused by Failed Aspirating Fan Motor.Motor Replaced | |
| 05000302/LER-1982-025-03, /03L-0:on 820322,while Performing Surveillance Procedure 179,station Air Valves SAV-23 & SAV-122 & Leakrate Valve LAV-46 Found Not Included on Procedure.Caused by Ineffective Administrative Control | /03L-0:on 820322,while Performing Surveillance Procedure 179,station Air Valves SAV-23 & SAV-122 & Leakrate Valve LAV-46 Found Not Included on Procedure.Caused by Ineffective Administrative Control | |
| 05000302/LER-1982-025, Forwards LER 82-025/03L-0 | Forwards LER 82-025/03L-0 | |
| 05000302/LER-1982-026-03, /03L-0:on 820326,during Procedural Review, Procedure Identified for Security Sodium Hydroxide Spray in Mode 4 Prior to Entry Into Mode 5,contrary to Tech Specs. Caused by Procedural Error.Procedure Rewritten | /03L-0:on 820326,during Procedural Review, Procedure Identified for Security Sodium Hydroxide Spray in Mode 4 Prior to Entry Into Mode 5,contrary to Tech Specs. Caused by Procedural Error.Procedure Rewritten | |