| | | Reporting criterion |
|---|
| 05000278/LER-1982-001-03, /03L-0:on 820105,during Surveillance Testing W/ Unit at Full Power,Main Steam Line Low Pressure Switch Found Below Min Tech Specs Setting of 850 Psig by 1.3% of Scale. Caused by Setpoint Drift of Barksdale Model B2T12SS Swit | /03L-0:on 820105,during Surveillance Testing W/ Unit at Full Power,Main Steam Line Low Pressure Switch Found Below Min Tech Specs Setting of 850 Psig by 1.3% of Scale. Caused by Setpoint Drift of Barksdale Model B2T12SS Switch | |
| 05000277/LER-1982-001-03, /03L-0:on 820123,during Startup,Local Leak Rate Test of Drywell Airlock Revealed Excess Leakage.Caused by Damaged Garlock Door Gaskets.Gaskets Replaced & Leak Rate Tested | /03L-0:on 820123,during Startup,Local Leak Rate Test of Drywell Airlock Revealed Excess Leakage.Caused by Damaged Garlock Door Gaskets.Gaskets Replaced & Leak Rate Tested | |
| 05000277/LER-1982-002-03, /03L-0:on 820204,during Local Leak Test on Oxygen Analyzer,Solenoid Valve SV-2980 Failed to Seat Properly. Caused by Buildup of Dirt on Seating surface.Dymo-type Solenoid Valve Atkomatic 15-644 Disassembled & Cleaned | /03L-0:on 820204,during Local Leak Test on Oxygen Analyzer,Solenoid Valve SV-2980 Failed to Seat Properly. Caused by Buildup of Dirt on Seating surface.Dymo-type Solenoid Valve Atkomatic 15-644 Disassembled & Cleaned | |
| 05000278/LER-1982-002-03, /03L-0:on 820331,during Maint Outage,Hydraulic snubbers,1-GG-S-30,1-GG-S-34 & 23-HBS-2A Found to Have Empty Reservoirs.Caused by Deterioration of Lynair 2.5-inch Hydraulic Seals.Seals Replaced & Snubbers Rebuilt | /03L-0:on 820331,during Maint Outage,Hydraulic snubbers,1-GG-S-30,1-GG-S-34 & 23-HBS-2A Found to Have Empty Reservoirs.Caused by Deterioration of Lynair 2.5-inch Hydraulic Seals.Seals Replaced & Snubbers Rebuilt | |
| 05000277/LER-1982-003-03, /03L-0:on 820129,during Power Operation,Diesel Generator Cardox Tank Level Dropped Below Tech Spec Limit. Caused by Stuck Level Indicator Float Mechanism (Cardox P/N 124109),due to Ice.Float Replaced & Sys Blown Down | /03L-0:on 820129,during Power Operation,Diesel Generator Cardox Tank Level Dropped Below Tech Spec Limit. Caused by Stuck Level Indicator Float Mechanism (Cardox P/N 124109),due to Ice.Float Replaced & Sys Blown Down | |
| 05000278/LER-1982-003-03, /03L-0:on 820413,core Spray Pump C Failed to Start Following Breaker Racking on 820329 for Valve Maint.Caused by Misaligned Pump Breaker Cell Switch.Breaker Reracked & Operator Counseled | /03L-0:on 820413,core Spray Pump C Failed to Start Following Breaker Racking on 820329 for Valve Maint.Caused by Misaligned Pump Breaker Cell Switch.Breaker Reracked & Operator Counseled | |
| 05000277/LER-1982-004-03, /03L-0:on 820206,during Surveillance Testing of Primary Containment Isolation Sys,Standby Gas Treatment Filter a Inlet Damper Failed to Automatically Open.Caused by Defective Damper Control Switch.Switch Replaced | /03L-0:on 820206,during Surveillance Testing of Primary Containment Isolation Sys,Standby Gas Treatment Filter a Inlet Damper Failed to Automatically Open.Caused by Defective Damper Control Switch.Switch Replaced | |
| 05000278/LER-1982-004-03, /03L-0:on 820410,while Performing Surveillance Tests on D Core Spray & D RHR Pumps,Room Cooler Fans Failed to Start W/Control Switches in Auto or Run Position.Caused by de-energized Control Circuit.Circuit re-energized | /03L-0:on 820410,while Performing Surveillance Tests on D Core Spray & D RHR Pumps,Room Cooler Fans Failed to Start W/Control Switches in Auto or Run Position.Caused by de-energized Control Circuit.Circuit re-energized | |
| 05000278/LER-1982-005-03, /03L-0:on 820514,during Normal Operation,Reactor Operator Heard Relay in Primary Containment Isolation Sys Energize.Caused by Defective Component in Rosemount Model 510DU Slave Trip Unit.Instrument Replaced | /03L-0:on 820514,during Normal Operation,Reactor Operator Heard Relay in Primary Containment Isolation Sys Energize.Caused by Defective Component in Rosemount Model 510DU Slave Trip Unit.Instrument Replaced | |
| 05000277/LER-1982-005-03, /03L-1:on 820215,pressure Drop Across Combined HEPA Filters & Charcoal Adsorber Banks in Control Room Emergency Ventilation Sys Exceeded Tech Spec Limits.Caused by Broken Linkage on Damper of OBV-30 Emergency Fan | /03L-1:on 820215,pressure Drop Across Combined HEPA Filters & Charcoal Adsorber Banks in Control Room Emergency Ventilation Sys Exceeded Tech Spec Limits.Caused by Broken Linkage on Damper of OBV-30 Emergency Fan | |
| 05000277/LER-1982-006-03, /03L-0:on 820313,during Surveillance Testing of Fire Protection Sys,Diesel Fire Pump Tripped Off on Overspeed Condition.Caused by Defective Overspeed Control Switch.Defective Switch Replaced | /03L-0:on 820313,during Surveillance Testing of Fire Protection Sys,Diesel Fire Pump Tripped Off on Overspeed Condition.Caused by Defective Overspeed Control Switch.Defective Switch Replaced | |
| 05000278/LER-1982-006-01, /01T-0:on 820504,GE Notified Util That Odyn Pressurization Event MCPR Values May Be Nonconservative. Caused by Nonconservative Value of Active Fuel Length Used in Reload 4 Odyn Transient Analysis | /01T-0:on 820504,GE Notified Util That Odyn Pressurization Event MCPR Values May Be Nonconservative. Caused by Nonconservative Value of Active Fuel Length Used in Reload 4 Odyn Transient Analysis | |
| 05000278/LER-1982-006, Forwards LER 82-006/01T-0.Detailed Event Analysis Submitted | Forwards LER 82-006/01T-0.Detailed Event Analysis Submitted | |
| 05000278/LER-1982-007-03, /03L-0:on 820519,during Operability Testing,Hpci Steam Inlet valve,MO-14,blew Fuses When Stroked & Turbine Stop valve,HO-5513,failed to Close in Response to Remote Trip Signal.Steam Inlet Valve Repacked & Switch Replaced | /03L-0:on 820519,during Operability Testing,Hpci Steam Inlet valve,MO-14,blew Fuses When Stroked & Turbine Stop valve,HO-5513,failed to Close in Response to Remote Trip Signal.Steam Inlet Valve Repacked & Switch Replaced | |
| 05000277/LER-1982-007-03, /03L-0:on 820321,refueling Floor Outboard Isolation Valve Failed to Operate.Caused by Stuck Plunger on 3-way Solenoid Valve SV 20452.Valve (Asc Model THT-8316B24) Removed,Repaired,Tested & Returned to Svc | /03L-0:on 820321,refueling Floor Outboard Isolation Valve Failed to Operate.Caused by Stuck Plunger on 3-way Solenoid Valve SV 20452.Valve (Asc Model THT-8316B24) Removed,Repaired,Tested & Returned to Svc | |
| 05000278/LER-1982-008, Forwards LER 82-008/01T-0.Detailed Event Analysis Submitted | Forwards LER 82-008/01T-0.Detailed Event Analysis Submitted | |
| 05000277/LER-1982-008, Forwards Revised LER 82-008/01X-1.Detailed Event Analysis Encl | Forwards Revised LER 82-008/01X-1.Detailed Event Analysis Encl | |
| 05000277/LER-1982-009-01, /01T:on 820329,during Shutdown for Refueling/Maint Outage,Crack Identified in B Core Spray Sparger During Insp of Reactor Vessel Internals Per IE Bulletin 80-13.Cause Unknown | /01T:on 820329,during Shutdown for Refueling/Maint Outage,Crack Identified in B Core Spray Sparger During Insp of Reactor Vessel Internals Per IE Bulletin 80-13.Cause Unknown | |
| 05000277/LER-1982-009, Forwards LER 82-009/01X-0.Detailed Event Analysis Submitted | Forwards LER 82-009/01X-0.Detailed Event Analysis Submitted | |
| 05000278/LER-1982-009-03, /03L-0:on 820530,operator Lost Valve Indication Position on HPCI Sys.Caused by Blown Fuse in Instrument Panel Due to Shortened Solenoid Coil in Turbine Exhaust Drain Valve.Fuse Replaced & Valves Stroked | /03L-0:on 820530,operator Lost Valve Indication Position on HPCI Sys.Caused by Blown Fuse in Instrument Panel Due to Shortened Solenoid Coil in Turbine Exhaust Drain Valve.Fuse Replaced & Valves Stroked | |
| 05000277/LER-1982-010, Sanitized Version of LER 82-010/01X-0:on 820413,Eberline Instrument Corp Reported 9.175 Rem Exposure to TLD Badge. Caused by Deliberate Tampering W/Badge Found Near Radiation Source.Individual Denied Access to Site | Sanitized Version of LER 82-010/01X-0:on 820413,Eberline Instrument Corp Reported 9.175 Rem Exposure to TLD Badge. Caused by Deliberate Tampering W/Badge Found Near Radiation Source.Individual Denied Access to Site | |
| 05000278/LER-1982-010-03, /03L-0:on 820618,downscale Failure of Drywell 0-70 Psig Pressure Recorder Occurred.Caused by Blown 0.3 Ampere Fuse Installed on Positive Side of Power Supply to Transmitter Circuit Board.Fuse Replaced | /03L-0:on 820618,downscale Failure of Drywell 0-70 Psig Pressure Recorder Occurred.Caused by Blown 0.3 Ampere Fuse Installed on Positive Side of Power Supply to Transmitter Circuit Board.Fuse Replaced | |
| 05000278/LER-1982-011-03, /03L-0:on 820620,fuse on Positive Leg to Transmitter Circuit Board Blew Causing Downscale Failure of Drywell 0-70 Psig Pressure Recorder.Caused by Intentional Ground Installed on Positive of Transmitter.Fuse Replaced | /03L-0:on 820620,fuse on Positive Leg to Transmitter Circuit Board Blew Causing Downscale Failure of Drywell 0-70 Psig Pressure Recorder.Caused by Intentional Ground Installed on Positive of Transmitter.Fuse Replaced | |
| 05000278/LER-1982-012-03, /03L-0:on 820806,at Normal Power,Reactor Bldg 3A Exhaust Radiation Monitor Experienced Downscale Failure. Caused by Failure of Geiger-Mueller Tube (GE Part 194x 927G011) Detector.Tube Replaced & Unit Calibr | /03L-0:on 820806,at Normal Power,Reactor Bldg 3A Exhaust Radiation Monitor Experienced Downscale Failure. Caused by Failure of Geiger-Mueller Tube (GE Part 194x 927G011) Detector.Tube Replaced & Unit Calibr | |
| 05000277/LER-1982-012-03, /03L-0:on 820517,pressure Drop Across Combined HEPA Filters & Charcoal Absorber Banks in Control Room Emergency Ventilation Sys Exceeded Tech Spec Limits.Caused by Pin on Connecting Linkage of Damper OBV-30 Falling Out | /03L-0:on 820517,pressure Drop Across Combined HEPA Filters & Charcoal Absorber Banks in Control Room Emergency Ventilation Sys Exceeded Tech Spec Limits.Caused by Pin on Connecting Linkage of Damper OBV-30 Falling Out | |
| 05000278/LER-1982-013-03, /03L-0:on 820807,torus Narrow Range Level Indicator Failed Downscale.Caused by Failure of Linkage on Foxboro Level Transmitter.Linkage Replaced & Transmitter Recalibr | /03L-0:on 820807,torus Narrow Range Level Indicator Failed Downscale.Caused by Failure of Linkage on Foxboro Level Transmitter.Linkage Replaced & Transmitter Recalibr | |
| 05000277/LER-1982-013-03, /03L-0:on 820608,while Filling Diesel Generator Carbon Dioxide Fire Suppression Sys Storage Tank,Tank Pressure Dropped Below Tech Spec Limit.Caused by Venting Tank Vapor Space to Atmosphere Instead of Delivery Truck | /03L-0:on 820608,while Filling Diesel Generator Carbon Dioxide Fire Suppression Sys Storage Tank,Tank Pressure Dropped Below Tech Spec Limit.Caused by Venting Tank Vapor Space to Atmosphere Instead of Delivery Truck | |
| 05000278/LER-1982-014-03, /03L-0:on 820811,loss of Channels 1 & 2 Required for Indication of Drywell Temp Occured During Surveillance Testing.Caused by Failed Detector Cards Due to Defective Power Supply for Indicator.Power Supply & Cards Replaced | /03L-0:on 820811,loss of Channels 1 & 2 Required for Indication of Drywell Temp Occured During Surveillance Testing.Caused by Failed Detector Cards Due to Defective Power Supply for Indicator.Power Supply & Cards Replaced | |
| 05000277/LER-1982-014-03, /03L-0:on 820701,after Installation of Modified Printed Circuit Board on Drywell Pressure Transmitter PT 2508B,transmitter PT 2508A Lost Signal.Caused by Blown Fuse Due to New Board.Original Board Reinstalled | /03L-0:on 820701,after Installation of Modified Printed Circuit Board on Drywell Pressure Transmitter PT 2508B,transmitter PT 2508A Lost Signal.Caused by Blown Fuse Due to New Board.Original Board Reinstalled | |
| 05000278/LER-1982-015-03, /03L-0:on 820822,drywell Pressure Recorder PR5805 Failed Downscale.Caused by Blown Fuse.Fuse Replaced & Sys Operation Verified | /03L-0:on 820822,drywell Pressure Recorder PR5805 Failed Downscale.Caused by Blown Fuse.Fuse Replaced & Sys Operation Verified | |
| 05000278/LER-1982-016-03, /03L-0:on 820831,while Operating at Power,Loss of Position Indication Observed on Motor Operated Steam Supply Valve MO-3-13-131 to RCIC Turbine.Caused by Grounded Relay Coil.Relay & Control Fuse Replaced | /03L-0:on 820831,while Operating at Power,Loss of Position Indication Observed on Motor Operated Steam Supply Valve MO-3-13-131 to RCIC Turbine.Caused by Grounded Relay Coil.Relay & Control Fuse Replaced | |
| 05000277/LER-1982-017-03, /03L-0:on 820825,diesel Overspeed Trip Alarm Sounded.Caused by Shorted Overspeed Trip Switch Due to Water Entering Switch Via Cracked Switch Housing.Switch & Valve Replaced | /03L-0:on 820825,diesel Overspeed Trip Alarm Sounded.Caused by Shorted Overspeed Trip Switch Due to Water Entering Switch Via Cracked Switch Housing.Switch & Valve Replaced | |
| 05000278/LER-1982-017-03, /03L-0:on 820902,during Heavy Rainstorm,Operator Observed That Vent Stack Flow Recorder Indicated Downscale on Both Channels.Caused by Pilot Tubes Filling W/Water During Severe Storm.Indication Returned When Storm Subsided | /03L-0:on 820902,during Heavy Rainstorm,Operator Observed That Vent Stack Flow Recorder Indicated Downscale on Both Channels.Caused by Pilot Tubes Filling W/Water During Severe Storm.Indication Returned When Storm Subsided | |
| 05000278/LER-1982-018-03, /03L-0:on 820924,torus Narrow Range Level Recorder Indicated Erratically.Investigation Determined Torus Water Level within Tech Spec.Caused by Const Personnel Knocking Instrument Out of Calibr.Personnel Counseled | /03L-0:on 820924,torus Narrow Range Level Recorder Indicated Erratically.Investigation Determined Torus Water Level within Tech Spec.Caused by Const Personnel Knocking Instrument Out of Calibr.Personnel Counseled | |
| 05000277/LER-1982-018-31, /03L-0:on 820724,while Testing Smoke Detectors in Cable Spreading Room,One Fire Damper Remained Open When Trip Was Initiated.Caused by Improperly Set Solenoid Release Mechanism (Derby Electric Release).Mechanism Reset & Test | /03L-0:on 820724,while Testing Smoke Detectors in Cable Spreading Room,One Fire Damper Remained Open When Trip Was Initiated.Caused by Improperly Set Solenoid Release Mechanism (Derby Electric Release).Mechanism Reset & Tested | |
| 05000277/LER-1982-019-03, /03L-0:on 820725,main Steam Line Radiation Monitors a & C Revealed hi-hi Trip Setpoints Greater than Tech Spec Limit.Caused by Instrument Zero Drift.Monitors Recalibr | /03L-0:on 820725,main Steam Line Radiation Monitors a & C Revealed hi-hi Trip Setpoints Greater than Tech Spec Limit.Caused by Instrument Zero Drift.Monitors Recalibr | |
| 05000278/LER-1982-019-03, /03L-0:on 820928,floor Cable Penetration Found W/ 1.5-square-inch Gap Due to Broken Marinite Barrier Board. Probably Caused by Impact to Kick Plate Encompassing Cable Tray Penetration.Board Repaired | /03L-0:on 820928,floor Cable Penetration Found W/ 1.5-square-inch Gap Due to Broken Marinite Barrier Board. Probably Caused by Impact to Kick Plate Encompassing Cable Tray Penetration.Board Repaired | |
| 05000277/LER-1982-020-03, /03L-0:on 820806,drywell Pressure Recorders PR-2508A & PR-2508B Failed Downscale Due to Blown Fuses. Caused by Intentional Ground on Positive Side of Transmitters.Mod to Eliminate Ground Completed on 820811 | /03L-0:on 820806,drywell Pressure Recorders PR-2508A & PR-2508B Failed Downscale Due to Blown Fuses. Caused by Intentional Ground on Positive Side of Transmitters.Mod to Eliminate Ground Completed on 820811 | |
| 05000278/LER-1982-020-03, /03L-0:on 821006,during Surveillance Test,Hpci Room Carbon Dioxide Fire Protection Sys Failed to Inject Automatically.Caused by Dirty Contacts on electro-manual Pilot Control Solenoid Valve.Contacts Cleaned | /03L-0:on 821006,during Surveillance Test,Hpci Room Carbon Dioxide Fire Protection Sys Failed to Inject Automatically.Caused by Dirty Contacts on electro-manual Pilot Control Solenoid Valve.Contacts Cleaned | |
| 05000278/LER-1982-021, Revised LER 82-021/01P:on 821101,3A Reactor Bldg Vent Stack Radiation Monitor Found to Have Less than Desired Sensitivity.Caused by Drift in Channel Voltage Plateau. Monitor Calibr & Returned to Svc | Revised LER 82-021/01P:on 821101,3A Reactor Bldg Vent Stack Radiation Monitor Found to Have Less than Desired Sensitivity.Caused by Drift in Channel Voltage Plateau. Monitor Calibr & Returned to Svc | |
| 05000277/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl | Forwards LER 82-021/03L-0.Detailed Event Analysis Encl | |
| 05000277/LER-1982-021-03, /03L-0:on 820620,combined Leakage for Type B & C Tests Exceeded 0.6 La.Caused by Failure of MSIV Due to Improper Seat Contact Resulting from Damaged Seats,Plugs & Guides.Valves Repaired & Tested | /03L-0:on 820620,combined Leakage for Type B & C Tests Exceeded 0.6 La.Caused by Failure of MSIV Due to Improper Seat Contact Resulting from Damaged Seats,Plugs & Guides.Valves Repaired & Tested | |
| 05000278/LER-1982-021-01, /01T-0:on 821101,during Source check,3A Reactor Vent Stack Radiation Monitor Determined Insensitive.Caused by Drift in Instrument Voltage Plateau.Instrument Realigned & Returned to Svc on 821102 | /01T-0:on 821101,during Source check,3A Reactor Vent Stack Radiation Monitor Determined Insensitive.Caused by Drift in Instrument Voltage Plateau.Instrument Realigned & Returned to Svc on 821102 | |
| 05000278/LER-1982-022-01, /01P:on 821104,determined 3D RHR HX Leaked Slightly Radioactive Water Into Intake Structure Via High Pressure Svc Water Piping During 821025-1102.Sys Isolated & HX Drain Valve Opened | /01P:on 821104,determined 3D RHR HX Leaked Slightly Radioactive Water Into Intake Structure Via High Pressure Svc Water Piping During 821025-1102.Sys Isolated & HX Drain Valve Opened | |
| 05000277/LER-1982-022-03, /03L-0:on 820820,main Control Room Intake Air Radiation Monitor B Failed Downscale.Caused by Defective Geiger-Mueller tube,194X927GO11.Tube & Associated Electronics Replaced.Detector Recalibr | /03L-0:on 820820,main Control Room Intake Air Radiation Monitor B Failed Downscale.Caused by Defective Geiger-Mueller tube,194X927GO11.Tube & Associated Electronics Replaced.Detector Recalibr | |
| 05000278/LER-1982-022, Revised LER 82-022/01X-1:on 821025-1102,RHR HX 3D Leaked Slightly Radioactive Water Into Intake Structure.Caused by Expansion Bellows Leak Between Inner Floating Head & Drain. HX Repaired | Revised LER 82-022/01X-1:on 821025-1102,RHR HX 3D Leaked Slightly Radioactive Water Into Intake Structure.Caused by Expansion Bellows Leak Between Inner Floating Head & Drain. HX Repaired | |
| 05000278/LER-1982-023-03, /03L-0:on 821209,during Surveillance Testing,Two HPCI Turbine Exhaust Rupture Discs Failed.Caused by High Back Pressure from Water in Exhaust Line.Water Pulled from Torus Due to Faulty Vacuum Breakers | /03L-0:on 821209,during Surveillance Testing,Two HPCI Turbine Exhaust Rupture Discs Failed.Caused by High Back Pressure from Water in Exhaust Line.Water Pulled from Torus Due to Faulty Vacuum Breakers | |
| 05000277/LER-1982-023-03, /03L-0:on 820908,reactor Core Isolation Cooling Governor Found W/Positive Ground During Routine Surveillance Test.Caused by Burned Out Resistor on Woodward Electric Governor Magnetic Servo.Resistor Replaced | /03L-0:on 820908,reactor Core Isolation Cooling Governor Found W/Positive Ground During Routine Surveillance Test.Caused by Burned Out Resistor on Woodward Electric Governor Magnetic Servo.Resistor Replaced | |
| 05000277/LER-1982-024-03, /03L-0:on 820827,pump Trip Annunicator Did Not Clear After Core Spray Surveillance Test.Caused by Misaligned Driving Pawl in 2D Core Spray Pump Motor Breaker Charging Spring.Pawl Realigned & Interlocks Reset | /03L-0:on 820827,pump Trip Annunicator Did Not Clear After Core Spray Surveillance Test.Caused by Misaligned Driving Pawl in 2D Core Spray Pump Motor Breaker Charging Spring.Pawl Realigned & Interlocks Reset | |
| 05000278/LER-1982-024-03, /03L-0:on 821209,fire Alarm Received from Core Spray Pump Rooms B & D & RHR Pump Room C.Caused by Reversed Wiring in B & D Core Spray & RHR Pump Room C.Wiring Corrected | /03L-0:on 821209,fire Alarm Received from Core Spray Pump Rooms B & D & RHR Pump Room C.Caused by Reversed Wiring in B & D Core Spray & RHR Pump Room C.Wiring Corrected | |