j O PSEG 4

Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station -

May 5, 1982 9

Mr.

R. C. Ilaynes Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Ilaynes:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 82-023/03L Pursuant to the requirements of Salem Generating Station Unit No.

1, Technical Specifications, Section 6.9.1.9.b, we are submitting Licensee Event Report for Reportable Occurrence ~82-023/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours, r

f.%

~

H.

J.

Midura General Manager Salem Operations RF:ks-CC:

Distribution 820518% 93 (

The Energy People f,O M 2 t S'>

W) 1181

~.

, Report Number:

82-023/03L Report Date:

Occurrence Date:

04-06-82 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Containment-Plant Vent Radioactivity Monitors - Inoperable.

1 This-report was initiated by Incident Report 82-075.

CONDITIONS PRIOR TO OCCURRENCE:

i 1

Mode 3 - Rx Power 0% -- Unit Load 0 MWe j

DESCRIPTION OF OCCURRENCE:

On April 6, 1982, while preparing for a gaseous release, the Control Room Operator noticed that the sample pump for the containment-plant vent radioactivity monitors was de-energized.

An investigation of the problem revealed that the air supply to Sample Valves IVC 8 and IVC 10.had been tagged out for maintenance.

The valves had failed in the closed position, causing the. pump to trip on thermal overload.

The monitors were declared in-operable, and Limiting Condition for Operation 3.3.3.1 Action l

20 was entered, retroactive to 1035 hours0.012 days <br />0.288 hours <br />0.00171 weeks <br />3.938175e-4 months <br /> when the air supply valve had been closed.

The gaseous release was not initiated.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

i i-DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

i The Shift Supervisor had approved the tagout of the air supply valve without regard to the loss of air to Valves IVC 8 and IVC 10.

f ANALYSIS OF OCCURRENCE:

l I

Technical Specification 3.3.3.1 Action 20 requires:

i l

With only two of the three required leakage detection i

systems operable, operation may continue for up to 30 days provided grab samples'of the containment atmosphere are obtained and analyzed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the gaseous and/or particulate radioactivity monitoring

- system is inoperable; otherwise, be in at least hot standby within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

.LER 82-023/03L CORRECTIVE ACTION:

The backup sample valves were opened, the pump was satis-factorily tested, and air flow was restored.

The containment-plant vent monitors were declared operable, and at 2053 hours0.0238 days <br />0.57 hours <br />0.00339 weeks <br />7.811665e-4 months <br />, April 6, 1982, Limiting Condition for Operation 3.3.3.1 Action 20 was terminated.

The Shift Supervisor involved was counseled by the Senior Shift Supervisor concerning Administrative Procedure AP-15, Safety Tagging Program.

FAILURE DATA:

Not Applicable

,d/NYS Prepared By R.

Frahm General Manager Salem Operations SORC Meeting No.

82-47