05000269/LER-1981-020, Forwards LER 81-020/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 81-020/03L-0.Detailed Event Analysis Encl
ML20033D286
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 11/25/1981
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20033D287 List:
References
NUDOCS 8112070491
Download: ML20033D286 (2)


LER-1981-020, Forwards LER 81-020/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
2691981020R00 - NRC Website

text

-

a a

DUKE power Codidi3/WO REGlon,

CEOi?hfA Powrn Duit.orwo 422 Sourir Gnuncti STREET, CIMRIDTTE, N. C. asa4a 31 H0V 30 AIO. q' w t L LIAM O. PAR M E R, J R.

%cr PotsioCNT TELEPh3ME. ARCA 704 StCam PaooucTtom 373-4083 November 25, 1981

~

Mr. James P. O'Reilly, Director Q

.( 1 \\, @

U. S. Nuclear Regulatory Commission Region II n

198N ~1 s

101 Marietta Street, Suite 3100

- j gg Atlanta, Georgia 30303 5

Re: Oconee Nuclear Station Docket No. 50-269

/

N

Dear Mr. 0'failly:

Please find attached Reportable Occurrence Report R0-269/81-20. This report ie submitted pursuant to Oconee Nuclear Station Technical Specification 6.6.2.1.b(2). which concerns operation in a degraded mode permitted by a limiting condition for operation, and describes an incident which is con-sidered to be of no significance with respect to its effect on the health and safety of the public.

Very truly yours,

/

L a. b i.__

William O. Parker, Jr.

JIT/php At.taciunent cc: Director Records Center Office of Management and Program Analysis Institute'of Nuclear Power Operations U. S. Nuclear Regulatory Conn tssion 1820 Water Place Washington, D. C. 20555 Atlanta, Georgia 30339 Mr. W. T. Orders NRC Resident Inspector Oconee Nuclear Station

's - -

~ ggpguytALUC '

811207049g gg33 y g

gDRADOCK 05000 69 Ab.

b

.PDR.

a

$1[l 1

DUKE POWER COMPANY OCONEE NUCLEAR STATION REPORT NUMBER: R0-269/81-20 REPORT DATE: Noven.ber 25, 1981 OCCURRENCE DATE: Octcber 29, 1981 FACIiJfTY; Oconee Nuclear Station, Seneca, South Carolina IDENTIFICATION OF OCCURRENCE: Oconee 1 Cold Shutdown Oconee 2 Startup in progress Oconee 3 100% FP DESCRIPTION OF OCCURRENCE: On October 29, 1981 the Hydrogen Purge Unit was declarud inoperable due to substandard heat output from the debumidifier heaters. This problem with the heater was identified during the Hydrogen Purge Unit Performance Test.

_ APPARENT CAUSE OF OCCURRENCE: The apparent cause of this event was a frayed conductor cable. The cause of the cable wear is suspected to be thermal embrittlement coupled with mechanical vibrations due to air flow.

ANALYSIS OF OCCURRTNCE: The Hydrogen Purge Unit was inoperable for only a few hours, and since the Unit would not be required until several days following a LOCA or MHA it is considered that this event did not affect the health and safety of the public. Additionally, it was determined that both Purge Unit heaters could be disabled by a single fault in the common-control circuitry or wiring.

CORRECTIVE ACTION

The frayed conductor cable was replaced and the Hydrogen Purge Unit declared operable. Wiring to the dehumidifier heaters will be modified to provide redundant circuits and independent monitoring of the heaters. Appropriate procedures will be revised to provide a more compre-hensive check of heater performance.